1/141 Copyright 2014 FUJITSU LIMITED Edition 138 as of December 5, 2014 Legend Supported( ): ( ) shows the versions of ETERNUS8000 firmware that support each server model. Planned 2: Support is planned. Availability varies depending on the business requirements. Please contact the Storage System Division. N.A.: Not Applicable. Contents Solaris (FC connection) Edition 1322014/2/19 Windows (FC connection) Edition 1372014/6/13 Linux (FC connection) Edition 1382014/12/05 VMware (FC connection) Edition 1382014/12/05 SPARC Enterprise Windows 2012R2 PRIMEQUEST ESXi 5 PRIMEPOWER Windows 2012 PRIMERGY (RHEL7) ESX 4 Other_Company_s_server_(x86_x64) Windows 2008R2 (PRIMEQUEST) PRIMERGY (RHEL6) ESX 3 Solaris (iSCSI connection) Edition 1332014/3/6 Windows 2008R2 (PRIMERGY) PRIMERGY (RHEL5) VMware (iSCSI connection) Edition 1382014/12/05 Solaris (FC-FCoE(switch) connection) Edition 1322014/2/19 Windows 2008R2 (Other Companies' server) PRIMERGY (RHEL4) ESXi 5 HP-UX (FC connection) Edition 1322014/2/19 Windows 2008(32) (PRIMEQUEST) PRIMERGY (SuSE) ESX 4 HP-UX 11iv3 Windows 2008(32) (PRIMERGY) Other_Companies' server (RHEL7) ESX 3 HP-UX 11iv2 Windows 2008(32) (Other Companies' server) Other Companies' server (RHEL6) VMware (FC-FCoE(switch) connection) Edition 1382014/12/05 HP-UX 11iv1 WINDOWS 2008(64) (PRIMEQUEST) Other Companies' server (RHEL5) Egenera (FC connection) Edition 1162013/1/25 AIX (FC connection) Edition 1162013/1/25 Windows 2008(64) (PRIMERGY) Other Companies' server (RHEL4) FC switch Edition 1382014/12/05 AIX 6.1 Windows 2008(64) (Other Companies' server) Other Companies' server (SuSE) AIX 5.3 Windows 2003 (32) Linux (iSCSI connection) Edition 1382014/12/05 AIX 5.2 Windows 2003 (64) PRIMEQUEST Windows (iSCSI connection) Edition 1372014/6/13 PRIMERGY Windows 2012R2 Other Companies' server Windows 2012 (Fujitsu Server) Linux (FC-FCoE(switch) connection) Edition 1052012/5/15 Windows 2012 (Other Companies' server) Windows 2008R2 Windows (FCoE connection) Edition 1332014/3/6 ETERNUS8000 Server Support matrix Planned 1: Support is scheduled by the indicated date. If the date is month, support is scheduled for the beginning of the month. If the date is nQ, support is scheduled during that quarter.

ETERNUS8000 Server Support Matrixstorage-system.fujitsu.com/global/manual/diskarray/pdf/e... · 2014. 12. 12. · Please use Oracle Solaris 10 OS 1/13 or later. - The maximum number

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • 1/141 Copyright 2014 FUJITSU LIMITED

    Edition 138 as of December 5, 2014

    Legend Supported( ): ( ) shows the versions of ETERNUS8000 firmware that support each server model.

    Planned 2: Support is planned. Availability varies depending on the business requirements. Please contact the Storage System Division. N.A.: Not Applicable.

    ContentsSolaris (FC connection) Edition 132:2014/2/19 Windows (FC connection) Edition 137:2014/6/13 Linux (FC connection) Edition 138:2014/12/05 VMware (FC connection) Edition 138:2014/12/05

    SPARC Enterprise Windows 2012R2 PRIMEQUEST ESXi 5

    PRIMEPOWER Windows 2012 PRIMERGY (RHEL7) ESX 4

    Other_Company_s_server_(x86_x64) Windows 2008R2 (PRIMEQUEST) PRIMERGY (RHEL6) ESX 3

    Solaris (iSCSI connection) Edition 133:2014/3/6 Windows 2008R2 (PRIMERGY) PRIMERGY (RHEL5) VMware (iSCSI connection) Edition 138:2014/12/05

    Solaris (FC-FCoE(switch) connection) Edition 132:2014/2/19 Windows 2008R2 (Other Companies' server) PRIMERGY (RHEL4) ESXi 5

    HP-UX (FC connection) Edition 132:2014/2/19 Windows 2008(32) (PRIMEQUEST) PRIMERGY (SuSE) ESX 4

    HP-UX 11iv3 Windows 2008(32) (PRIMERGY) Other_Companies' server (RHEL7) ESX 3

    HP-UX 11iv2 Windows 2008(32) (Other Companies' server) Other Companies' server (RHEL6) VMware (FC-FCoE(switch) connection) Edition 138:2014/12/05

    HP-UX 11iv1 WINDOWS 2008(64) (PRIMEQUEST) Other Companies' server (RHEL5) Egenera (FC connection) Edition 116:2013/1/25

    AIX (FC connection) Edition 116:2013/1/25 Windows 2008(64) (PRIMERGY) Other Companies' server (RHEL4) FC switch Edition 138:2014/12/05

    AIX 6.1 Windows 2008(64) (Other Companies' server) Other Companies' server (SuSE)

    AIX 5.3 Windows 2003 (32) Linux (iSCSI connection) Edition 138:2014/12/05

    AIX 5.2 Windows 2003 (64) PRIMEQUEST

    Windows (iSCSI connection) Edition 137:2014/6/13 PRIMERGY

    Windows 2012R2 Other Companies' server

    Windows 2012 (Fujitsu Server) Linux (FC-FCoE(switch) connection) Edition 105:2012/5/15

    Windows 2012 (Other Companies' server)

    Windows 2008R2

    Windows (FCoE connection) Edition 133:2014/3/6

    ETERNUS8000 Server Support matrix

    Planned 1: Support is scheduled by the indicated date. If the date is month, support is scheduled for the beginning of the month. If the date is nQ, support is scheduled during that quarter.

  • 2/141 Copyright 2014 FUJITSU LIMITED

    - Solaris™ Operating System is described as Solaris OS.

    - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers.

    - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.

    700/900/1100/2100

    800/1200/2200

    Direct/via switch

    PCI-Express

    SP1X7FAA2F/SP1X7FAB2F7101673/7101674

    (+7101679/71016807101675/7101676)

    OS bundled MPxIO PCL 4.3A20 YesSupported

    (V20L86 or later)Supported

    (V10L52 or later)

    Direct/via switch

    PCI-ExpressSP1X7FBA2F

    7101683/7101684( +7101685/7101686)

    OS bundled MPxIO PCL 4.3A20 YesSupported

    (V20L86 or later)Supported

    (V10L52 or later)

    Direct/via switch

    PCI-Express

    SE0X7F21F/SE0X7F22F/SG-PCIE1FC-QF8-Z/SG-PCIE2FC-QF8-Z/

    SG-XPCIE1FC-QF8-N/SG-XPCIE2FC-QF8-N

    OS bundled MPxIO OSC4.1 NoSupported

    (V20L86 or later)Supported

    (V10L52 or later)

    Direct/via switch

    PCI-Express

    SE0X7F31F/SE0X7F32F/SG-PCIE1FC-EM8-Z/SG-PCIE2FC-EM8-Z/

    7105391/SG-XPCIE2FC-EM8-N

    OS bundled MPxIO OSC4.1 NoSupported

    (V20L86 or later)Supported

    (V10L52 or later)

    Direct/via switch

    PCI-Express

    SE0X7F21F/SE0X7F22F/SG-PCIE1FC-QF8-Z/SG-PCIE2FC-QF8-Z/

    SG-XPCIE1FC-QF8-N/SG-XPCIE2FC-QF8-N

    OS bundledVxVM6.0.3

    VCS 6.0.3(including Oracle RAC)

    NoSupported

    (V20L86 or later)Supported

    (V10L52 or later)

    Direct/via switch

    PCI-Express

    SE0X7F31F/SE0X7F32F/SG-PCIE1FC-EM8-Z/SG-PCIE2FC-EM8-Z/

    7105391/SG-XPCIE2FC-EM8-N

    OS bundledVxVM6.0.3

    VCS 6.0.3(including Oracle RAC)

    NoSupported

    (V20L86 or later)Supported

    (V10L52 or later)

    Direct/via switch

    PCI-Express

    SE0X7F21F/SE0X7F22F/SG-PCIE1FC-QF8-Z/SG-PCIE2FC-QF8-Z/

    SG-XPCIE1FC-QF8-N/SG-XPCIE2FC-QF8-N

    OS bundled MPxIO PCL 4.3A20 YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express

    SE0X7F31F/SE0X7F32F/SG-PCIE1FC-EM8-Z/SG-PCIE2FC-EM8-Z/

    7105391/SG-XPCIE2FC-EM8-N

    OS bundled MPxIO PCL 4.3A20 YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express

    SE0X7F21F/SE0X7F22F/SG-PCIE1FC-QF8-Z/SG-PCIE2FC-QF8-Z/

    SG-XPCIE1FC-QF8-N/SG-XPCIE2FC-QF8-N

    YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express

    SE0X7F31F/SE0X7F32F/SG-PCIE1FC-EM8-Z/SG-PCIE2FC-EM8-Z/

    7105391/SG-XPCIE2FC-EM8-N

    YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    - Veritas products' drivers for ETERNUS8000 can be downloaded from the following website. The installation instructions are also described on the website. - for Solaris OS: VxVM 5.0 - http://entkb.symantec.com/security/output/a286532.html VxVM 4.1 - http://entsupport.symantec.com/docs/a284170

    Solaris FC connection [Edition 132 : February 19, 2014]

    - GR MultipathDriver is described as "GRMPD", and ETERNUS MultipathDriver is described as "EMPD". - GRMPD has been terminated.

    Fujitsu M10

    Notes - The cluster configurations shown in the table are all 2-node cluster system. Please contact the Storage System Division when two or more clusters are connected to one ETERNUS8000 or one cluster consists of more than 2 nodes.

    Solaris 11 OS

    Refer to"FC switch

    pages"for supportedFC switches.

    - Please use Oracle Solaris 11.1 or later.

    - Please use Oracle Solaris 11.1 or later.- For OSC notes, please refer to OSC handbook.

    - Please use Oracle Solaris 11.1 or later.- The maximum number of LUNs per server is up to 128 when using VxVM 6.0.3.When configuring cluster by Veritas environment, there is a limitation of number of pathsfrom one storage. Please satisfy the formula below. # of LUNs shared among cluster x # of paths to the LUN from one node x # of nodes <4096When one storage is used by multiple clusters, then # of path is the sum of all cluster'spath.

    Cluster System

    Model

    Solaris System OS ConnectedType Bus HBA Driver Version Path Failover

    Please use Oracle Solaris 11.1 or later.

    OS bundled MPxIO OracleRAC

    SAN boot Instruction for useSwitch

  • 3/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    Direct/via switch

    PCI-Express

    SP1X7FAA2F/SP1X7FAB2F7101673/7101674

    (+7101679/71016807101675/7101676)

    OS bundled MPxIO PCL 4.3A20 Yes Planned 2Supported

    (V20L86 or later)Please use Oracle Solaris 10 OS 1/13 or later.

    Direct/via switch

    PCI-Express

    SP1X7FBA2F7101683/7101684

    ( +7101685/7101686)OS bundled MPxIO PCL 4.3A20 Yes Planned 2

    Supported(V20L86 or later)

    Please use Oracle Solaris 10 OS 1/13 or later.

    Direct/via switch

    PCI-Express

    SE0X7F21F/SE0X7F22F/SG-PCIE1FC-QF8-Z/SG-PCIE2FC-QF8-Z/

    SG-XPCIE1FC-QF8-N/SG-XPCIE2FC-QF8-N

    OS bundled MPxIO OSC3.3 3/13 No Planned 2Supported

    (V20L86 or later)

    Direct/via switch

    PCI-Express

    SE0X7F31F/SE0X7F32F/SG-PCIE1FC-EM8-Z/SG-PCIE2FC-EM8-Z/

    7105391/SG-XPCIE2FC-EM8-N

    OS bundled MPxIO OSC3.3 3/13 No Planned 2Supported

    (V20L86 or later)

    MPxIO PCL 4.3A20 YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    MPxIO OracleRAC YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    VxVM 6.0.3VCS 6.0.3

    (including Oracle RAC)No Planned 2

    Supported(V20L71 or later)

    MPxIO PCL 4.3A20 YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    MPxIO OracleRAC YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    VxVM 6.0.3VCS 6.0.3

    (including Oracle RAC)No Planned 2

    Supported(V20L71 or later)

    7101673/71016747101681/7101682

    (+7101679/71016807101675/7101676)

    Yes Planned 2Supported

    (V20L86 or later)

    7101683/71016847101689/7101690

    ( +7101685/7101686)Yes Planned 2

    Supported(V20L86 or later)

    SG-XPCIE1FC-EM8/SG-XPCIE2FC-EM8

    No Planned 2Supported

    (V20L86 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    No Planned 2Supported

    (V20L86 or later)

    Direct/via switch

    PCI-ExpressSE0X7F21FSE0X7F22FSE5X7F22G

    OS bundled MPxIO - YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-ExpressSE0X7F31F/SE0X7F32FSE5X7F32G

    OS bundled MPxIO - YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z

    OS bundled MPxIO - YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z

    OS bundled MPxIO - YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIEFCGBE-E8-N Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIE1FC-EM8-Z/SG-XPCIE2FC-EM8-Z

    Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIEFCGBE-Q8-N Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIE1FC-QF8-Z/SG-XPCIE2FC-QF8-Z

    Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIEFCGBE-E8-N Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIE1FC-EM8-Z/SG-XPCIE2FC-EM8-Z

    Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIEFCGBE-Q8-N Yes Planned 2Supported

    (V20L71 or later)

    Direct/via switch

    PCI-Express SG-XPCIE1FC-QF8-Z/SG-XPCIE2FC-QF8-Z

    Yes Planned 2Supported

    (V20L71 or later)

    Cluster System SAN boot

    ModelInstruction for use

    SPARC ServersSPARC Enterprise

    SUN Fire

    Fujitsu M10

    Solaris system OS ConnectedType Bus HBA Driver Version Switch Path Failover

    Please use Oracle Solaris 10 OS 1/13 or later.For OSC notes, please refer to OSC handbook.

    Solaris 10 OS

    Refer to"FC switch

    pages"for supportedFC switches.

    VxVM6.0.1 to 6.0.3

    VCS 6.0.1 to 6.0.3(including Oracle RAC)

    - Please use Oracle Solaris 11.1 or later.- The maximum number of LUNs per server is up to 128 when using VxVM 6.0.x.When configuring cluster by Veritas environment, there is a limitation of number of pathsfrom one storage. Please satisfy the formula below. # of LUNs shared among cluster x # of paths to the LUN from one node x # of nodes <4096When one storage is used by multiple clusters, then # of path is the sum of all cluster'spath.

    Direct/via switch

    PCI-bus/PCI-Express

    OS bundled MPxIO OracleRAC Please use Oracle Solaris 11.1 or later.

    Solaris 11 OS

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Direct/via switch

    PCI-bus/PCI-Express

    OS bundled

    SE0X7F31F/SE0X7F32F/SG-PCIE1FC-EM8-Z/SG-PCIE2FC-EM8-Z/

    7105391/SG-XPCIE2FC-EM8-N

    OS bundled

    MPxIO OSC4.0

    Direct/via switch

    PCI-Express

    SE0X7F21F/SE0X7F22F/SG-PCIE1FC-QF8-Z/SG-PCIE2FC-QF8-Z/

    SG-XPCIE1FC-QF8-N/SG-XPCIE2FC-QF8-N

    OS bundled Please use Oracle Solaris 10 OS 1/13 or later.

    - The maximum number of LUNs per server is up to 128 when using VxVM 6.0.3.When configuring cluster by Veritas environment, there is a limitation of number of pathsfrom one storage. Please satisfy the formula below. # of LUNs shared among cluster x # of paths to the LUN from one node x # of nodes <4096When one storage is used by multiple clusters, then # of path is the sum of all cluster'spath.

    Direct/via switch

    PCI-Express

    OS bundled MPxIO OSC4.1 Please use Oracle Solaris 11.1

    OS bundled Please use Oracle Solaris 11 11/11

  • 4/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    7101673/71016747101681/7101682

    (+7101679/71016807101675/7101676)

    Yes Planned 2Supported

    (V20L86 or later)

    7101683/71016847101689/7101690

    ( +7101685/7101686)Yes Planned 2

    Supported(V20L86 or later)

    PCI-Express SG-XPCIEFCGBE-Q8-N Yes Planned 2Supported

    (V20L71 or later)

    PCI-ExpressSG-XPCIE1FC-EM8-Z/SG-XPCIE2FC-EM8-Z

    Yes Planned 2Supported

    (V20L71 or later)

    PCI-Express SG-XPCIEFCGBE-Q8-N Yes Planned 2Supported

    (V20L71 or later)

    PCI-ExpressSG-XPCIE1FC-QF8-Z/SG-XPCIE2FC-QF8-Z

    Yes Planned 2Supported

    (V20L71 or later)

    V4.0EMPD 2.0.3

    or laterPCL 4.2A00 Yes

    Supported(V10L70 or later)

    Supported(V20L11 or later)

    Please apply patch 914267-04 or later when usingEMPD prior to 2.0.2.

    V4.0 EMPDOracleRAC11gR2

    (see Instruction for use)Yes

    Supported(V11L80 or later)

    Supported(V20L60 or later)

    11.2.0(GA) and 11.2.0.2 are supported.

    V4.0 VxVM5.0VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L70 or later)Supported

    (V20L11 or later)

    When using VxVM 5.0, the maximum number of LUNs is 128 per server.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672

    V4.0 VxVM5.1VCS 5.1

    (including Oracle RAC)Note 1

    YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)When using VxVM 5.1, the maximum number of LUNs is 128 per server.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.

    MPxIO PCL 4.2A00 YesSupported

    (V11L56 or later)Supported

    (V20L12 or later)Please apply Solaris 10 OS patch 125166-12 or later.Solaris OS 10/08 or later, PTF R08111 or later include the above patch.

    MPxIO Sun Cluster 3.3 Yes Planned 2 Planned 2

    MPxIOOracleRAC11gR2

    (see Instruction for use)Yes

    Supported(V11L80 or later)

    Supported(V20L60 or later)

    11.2.0(GA) and 11.2.0.2 are supported.

    VxVM5.0VCS 5.0

    (including Oracle RAC)Note 1

    YesSupported

    (V11L56 or later)Supported

    (V20L12 or later)

    Solaris 10 OS 10/08 PTF R09051VERITAS Storage Foundation Standard 5.0 MP1When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672

    VxVM5.1VCS 5.1

    (including Oracle RAC)Note 1

    YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)When using VxVM 5.1, the maximum number of LUNs is 128 per server.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.

    ConnectedType

    SAN boot

    ModelInstruction for useBus HBA Driver Version Switch Path Failover Cluster System

    SPARC ServersSPARC Enterprise

    SUN Fire

    Solaris system OS

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Direct/via switch

    PCI-Express

    Direct/via switch

    PCI-bus/PCI-Express

    OS bundled

    Solaris 10 OS

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    SE0X7F11X/SE0X7F12X

    OS bundled

    PCI-Express

    Direct/via switch

    OS bundled

    SE0X7F21XSE0X7F22X

    MPxIO OracleRAC

    Please use OSC3.3 3/13 and Oracle Solaris 10 1/13

    Please use Oracle Solaris 10 1/13 or later.

    MPxIO OSC3.3 3/13

  • 5/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    VxVM5.1VCS 5.1

    (including Oracle RAC)Note 1

    YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    MPxIO - YesSupported

    (V10L70 or later)Supported

    (V20L11 or later)

    MPxIOOracleRAC11gR2

    (see Instruction for use)Yes

    Supported(V11L80 or later)

    Supported(V20L60 or later)

    11.2.0(GA) and 11.2.0.2 are supported.

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled MPxIO - YesSupported

    (V10L70 or later)Supported

    (V20L11 or later)SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4/

    XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU

    SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4

    XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU

    OS bundled MPxIO Sun Cluster 3.2 YesSupported

    (V11L12or later)Supported

    (V20L11 or later)When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.

    SG-XPCI1FC-EM4-Z/SG-XPCI2FC-EM4-Z/

    XSPFC401EU/XSPFC402EU,XAPFC401EU/XAPFC402EU

    SG-XPCI1FC-QF4/SG-XPCI2FC-QF4/

    XSPFC401QU/XSPFC402QU,XAPFC401QU/XAPFC402QU

    OS bundled MPxIO Sun Cluster 3.2 YesSupported

    (V11L12or later)Supported

    (V20L11 or later)When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.

    Solaris 10 OS9/10 or later

    Direct/via switch

    PCI-Express SE5X7F22G/SE5X7F32G

    OS bundled MPxIO - YesSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Solaris 108/07 or later

    Direct/via switch

    PCI-Express

    SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-ZSG-XPCIE1FC-EM8-ZSG-XCPIE2FC-EM8-Z

    OS bundled MPxIO Sun Cluster 3.2 YesSupported

    (V11L56 or later)Supported

    (V20L12 or later)

    When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM(SUN-OEM).VxVM5.0 which needs patch MP1 RP5 or later.Solaris patch 125511-02/125517-03/126047-06 should be applied.

    OS bundled MPxIO - YesSupported

    (V10L70 or later)Supported

    (V20L11 or later)When using Emulex HBA cards, please apply patch ID:120222-23.

    OS bundled VxVM5.0VCS 5.0

    (including Oracle RAC)Note 1

    YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    Solaris patch: PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    OS bundled MPxIO - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)When using Emulex HBA cards, please apply patch ID:120222-23.

    OS bundled VxVM5.0VCS 5.0

    (including Oracle RAC)Note 1

    YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    Solaris patch: PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    OS bundled MPxIO - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    OS bundled VxVM5.0VCS 5.0

    (including Oracle RAC)Note 1

    YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    Solaris patch: PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    OS bundled MPxIO - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    OS bundled VxVM5.0VCS 5.0

    (including Oracle RAC)Note 1

    YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    Solaris patch: PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-EM4-Z/SG-XPCI2FC-EM4-Z,

    XSPFC401EU/XSPFC402EU,XAPFC401EU/XAPFC402EU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,

    XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-QF4/SG-XPCI2FC-QF4,

    XSPFC401QU/XSPFC402QU,XAPFC401QU/XAPFC402QU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,

    XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU

    OS bundled Yes Planned 2 Planned 2

    PCI-Express

    SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z

    XSEFC801AUXSEFC802AU

    OS bundled Yes Planned 2 Planned 2

    PCI-Express

    SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z

    XSEFC801QUXSEFC802QU

    OS bundled Yes Planned 2 Planned 2

    ModelInstruction for useDriver Version Cluster SystemSwitch SAN boot

    ConnectedType

    Path Failover

    Direct/via switch

    Solaris system OS

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    PCI-bus/PCI-

    Express

    Direct/via switch

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Sun Cluster 3.3

    HBA

    Solaris 10 OS

    Bus

    Solaris 10 OS

    Direct/via switch

    PCI-bus/PCI-

    Express

    PCI-bus/PCI-

    Express

    SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,

    XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU

    SG-XPCI1FC-EM4-Z/SG-XPCI2FC-EM4-Z,

    XSPFC401EU/XSPFC402EU,XAPFC401EU/XAPFC402EU

    SG-XPCI1FC-QF4/SG-XPCI2FC-QF4,

    XSPFC401QU/XSPFC402QU,XAPFC401QU/XAPFC402QU

    SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,

    XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    MPxIO

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    SPARC ServersSPARC Enterprise

    SUN Fire

    SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,

    XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU

    OS bundled

    via switch

  • 6/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled YesSupported

    (V11L12or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled YesSupported

    (V11L12or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,

    XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,

    XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU

    OS bundled No Planned 2Supported

    (V20L15 or later)

    Direct/via switch

    PCI-Express

    SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z

    XSEFC801AUXSEFC802AU

    OS bundled YesSupported

    (V11L56 or later)Supported

    (V20L15 or later)

    Direct/via switch

    PCI-Express

    SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z

    XSEFC801QUXSEFC802QU

    OS bundled YesSupported

    (V11L56 or later)Supported

    (V20L15 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    Direct/via switch

    PCI-Express LPe12000/LPe12002 6.30g VxVM5.0 MP1VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V11L41 or later)Supported

    (V20L11 or later)

    Solaris patch: PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    PCI-bus LP10000/LP10000DC 6.30g No Planned 2Supported

    (V20L15 or later)

    PCI-bus/PCI-Express

    LP11000/LP11002/LPe11000/LPe11002

    6.30g No Planned 2Supported

    (V20L15 or later)

    PCI-busQLA2340/QLA2342/QLA2460/QLA2462

    5.04 No Planned 2Supported

    (V20L15 or later)

    PCI-Express QLE2560/QLE2562 5.04 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    PCI-bus/PCI-Express

    LP10000/LP10000DC/LP1050/LP1050DC/

    LP1050Ex/LP10000ExDC6.30g Yes

    Supported(V11L80 or later)

    Supported(V20L43 or later)

    PCI-Express QLE2560/QLE2562 V5.05 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    MPxIO

    When using Veritas 5, please apply Storage Foundation Enterprise for Oracle RAC 5.0MP1/ MP necessary patch/ MP1 Patch fix file/ MP1 PointPatch, MP1 Rolling Patch2, MP1Rolling Patch3.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.

    MPxIO

    When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM(SUN-OEM).VxVM5.0 which needs patch MP1 RP5 or later.Solaris patch 125511-02/125517-03/126047-06 should be applied.

    VxVM 5.1When using VxVM 5.1, the maximum number of LUNs is 128 per server.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.

    VCS 5.0(including Oracle RAC)

    Note 1

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Switch Path Failover

    MPxIO

    PCI-bus/PCI-Express

    Solaris 10 OS

    Solaris 108/07 or later

    Direct/via switch

    VxVM5.0 MP1

    Solaris system

    Direct/via switch

    Direct/via switch

    Direct/via switch

    PCI-bus/PCI-Express

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    PCI-bus/PCI-Express

    Solaris 10OS

    HBA

    Direct

    Bus Driver VersionOS Instruction for use

    VCS 5.1(including Oracle RAC)

    Note 1

    SAN boot

    Model

    11.2.0(GA) and 11.2.0.2 are supported.

    When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM(SUN-OEM).VxVM5.0 which needs patch MP1 RP5 or later.Solaris patch 125511-02/125517-03/126047-06 should be applied.

    Sun Cluster 3.2

    Sun Cluster 3.2

    OracleRAC11gR2(see Instruction for use)

    Cluster System

    via switchPCI-bus/

    PCI-Express

    SPARC ServersSPARC Enterprise

    SUN Fire

    Solaris 10 OS

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    ConnectedType

  • 7/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    GP7B8FC1U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC2U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC3U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    GP7B8FC1U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC2U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC3U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)PW028FC4U/PW028FC5U,

    LP10000/LP10000DCV6.02h Yes

    Supported(V10L24 or later)

    Supported(V20L11 or later)

    GP7B8FC1U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC2U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC3U V2.2.1/V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)PW028FC4U/PW028FC5U,

    LP10000/LP10000DCV6.02h Yes

    Supported(V10L24 or later)

    Supported(V20L11 or later)

    PW008FC2U V2.2.1/V3.0 NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    Solaris 8 patch: PTF:R00721 PATCH:117350-38 should be applied when using Veritas 5.Solaris 9 patch: PTF:R00721 PATCH:118558-21 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    V6.02h VxVM4.1 + MP1Veritas VCS 4.1 + MP1(including Oracle RAC)

    Note 1No

    Supported(V10L24 or later)

    Supported(V20L11 or later)

    V6.11cx2

    GRMPD1.0.7 or later

    (in EMPD2.0.1through 2.0.3 pkg)

    - YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    V6.11cx2 VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    LP10000/LP10000DC SFS 4.4.10 MPxIO - NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    When using Emulex HBA cards, please apply the following patch;For Solaris 9 patch ID:119914-13.For Solaris 8 patch ID:119913-13.

    PW008FC3 V3.0 update1 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    LP10000/LP10000DC/LP1050/LP1050DC/

    LP1050Ex/LP10000ExDC6.30g Yes

    Supported(V11L80 or later)

    Supported(V20L43 or later)

    GP7B8FC1U V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC2U V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    PW008FC3U V3.0 YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)PW028FC4U/PW028FC5U,

    LP10000/LP10000DCV6.02h Yes

    Supported(V10L24 or later)

    Supported(V20L11 or later)

    PW008FC2/PW008FC3 V3.0 update1 EMPDOracleRAC11gR2

    (see Instruction for use)Yes

    Supported(V11L80 or later)

    Supported(V20L60 or later)

    11.2.0(GA) and 11.2.0.2 are supported.

    PW008FC2U V3.0 NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    Solaris patch: PTF:R00721 PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    V6.02h VxVM4.1 + MP1VCS 4.1 + MP1

    (including Oracle RAC)Note 1

    NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    V6.11cx2EMPD 2.0.0

    or later- Yes

    Supported(V10L62 or later)

    Supported(V20L11 or later)

    V6.11cx2 VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    LP10000/LP10000DC OS bundled MPxIO - NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)When using Emulex HBA cards, please apply PTF R08021 or patch ID:120222-23.

    When using mirroring function of PRIMECLUSTER GDS 4.1A40, the following patch isrequired. - 914258-03 or later patch

    Instruction for useSwitch

    PW028FC4U/PW028FC5U,LP10000/LP10000DC

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Directvia switch

    EMPD2.0.2patch

    914267-03required or later

    PRIMECLUSTER4.1A40/4.2A00

    Model

    EMPD2.0.2patch

    914267-03required or later

    Directvia switch

    PCI-bus

    V3.0

    HBA

    Solaris 9 OS

    SAN bootDriver Version

    When using mirroring function of PRIMECLUSTER GDS 4.1A40, the following patch isrequired. - 914258-03 or later patch

    GRMPD older than 1.0.7 can be used by applying patch 912651-14 or newer.

    GRMPD 1.0.7 or later

    (in EMPD2.0.1through 2.0.3

    pkg)

    Solaris system Path Failover

    Solaris 7/8/9OS

    Solaris 9 OS Directvia switch

    ConnectedType

    Directvia switch

    Directvia switch

    PRIMEPOWER

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    VxVM4.1 + MP1

    PW008FC3USolaris 10 OS

    PW028FC4U/PW028FC5U,LP10000/LP10000DC

    PCI-bus/PCI-Express

    Cluster System

    Directvia switch

    PCI-bus

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    V2.2.1/V3.0

    Solaris 8 OSPCI-bus

    Bus

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    OS

    When using mirroring function of PRIMECLUSTER GDS 4.1A40, the following patch isrequired. - 914258-03 or later patch

    PRIMECLUSTER4.1A40/4.2A00

    PRIMECLUSTER4.1A40

    GRMPD older than 1.0.7 can be used by applying patch 912651-14 or newer.

    When using VxVM 5.1, the maximum number of LUNs is 128 per server.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.

    VxVM4.1 + MP1

    Solaris 8/9OS

    PW008FC3U

    VCS 4.1 + MP1(including Oracle RAC)

    Note 1

    VCS 4.1 + MP1(including Oracle RAC)

    Note 1

    GRMPD 1.0.7 or later

    (in EMPD2.0.1through 2.0.3

    pkg)

    VxVM5.1

    -

    VCS 5.1(including Oracle RAC)

    Note 1

  • 8/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    LP10000/LP10000DC V6.02h NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    LP11000/LP11002/LPe11000/LPe11002

    V6.02h NoSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    LP10000/LP10000DC V6.11cx2/V6.30G NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    LP11000/LP11002/LPe11000/LPe11002

    V6.11cx2/V6.30G NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    Solaris8/9 OS

    Directvia switch

    LPe12000/LPe12002 V6.30g NoSupported

    (V11L41 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    SFS 4.4.10 YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    SFS 4.4.10 YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI2FC-QF2/SG-XPCI2FC-QF2-Z

    SFS 4.4.10 YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    SFS 4.4.13 - YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.13 - YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    SFS 4.4.13 - YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.13 - YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    SFS 4.4.12 YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.12 YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    SFS 4.4.12 YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.12 YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    SFS 4.4.10 YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    SFS 4.4.10 YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI2FC-QF2/SG-XPCI2FC-QF2-Z

    SFS 4.4.10 YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    SFS 4.4.13 YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.13 YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    SFS 4.4.13 YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.13 YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    Direct/via switch

    QLA2340/QLA2342QLA2460/QLA2462

    5.02 VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L70 or later)Supported

    (V20L11 or later)

    HBA driver patch: Patch 113042-17(for Solaris 9), Patch 111097-25(for Solaris 8) shouldbe applied.Solaris patch: 111413-06 should be applied for Solaris 8 when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    PCI-ExpressLPe12000/LPe12002

    6.30g No Planned 2Supported

    (V20L15 or later)

    PCI-busQLA2340/QLA2342/QLA2460/QLA2462

    5.04 No Planned 2Supported

    (V20L15 or later)

    PCI-Express QLE2560/QLE2562 5.04 No Planned 2Supported

    (V20L15 or later)

    Bus Instruction for usePath Failover

    MPxIO2-node configuration is supported.When using SunCluster 3.1, volume management is Veritas4.0/4.1-VxVM(SUN-OEM).Apply MP2 RP3 or later patch.

    -

    VxVM4.1 + MP1

    PCI-bus/PCI-Express

    Solaris system ConnectedType

    VxVM 5.0When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    VCS 4.1 + MP1(including Oracle RAC)

    Note 1

    VCS 5.0(including Oracle RAC)

    Note 1

    MPxIO

    Solaris 8 patch: PATCH:117350-38 should be applied when using Veritas 5.Solaris 9 patch: PATCH:118558-21 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    VCS 5.0(including Oracle RAC)

    Note 1

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    VCS 5.0(including Oracle RAC)

    Note 1

    SAN boot

    Model

    Directvia switch

    VxVM5.0 MP1

    SUN Cluster 3.1

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    via switch

    Direct/via switch

    SUN Fire

    Solaris8/9 OS

    Solaris8/9/10 OS

    PCI-bus/PCI-Express

    Directvia switch

    Directvia switch

    HBA Driver Version Switch

    When using Veritas 5, please apply StorageFoundation Enterprise for Oracle RAC 5.0MP1/ MP necessary patch/ MP1 Patch fix file/ MP1 PointPatch, MP1 Rolling Patch2, MP1Rolling Patch3.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    OS

    Solaris8/9/10 OS

    When using Veritas 5, please apply Storage Foundation Enterprise for Oracle RAC 5.0MP1/ MP necessary patch/ MP1 Patch fix file/ MP1 PointPatch, MP1 Rolling Patch2, MP1Rolling Patch3.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Cluster System

    VxVM5.0 MP1VCS 5.0

    (including Oracle RAC)Note 1

    VxVM 5.0

  • 9/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    SFS 4.4.13/SFS 4.4.15

    YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4SG-XPCI2FC-EM4

    SFS 4.4.13/SFS 4.4.15

    YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.13/SFS 4.4.15

    YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    SFS 4.4.13/SFS 4.4.15

    YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    SFS 4.4.13/SFS 4.4.15

    YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.13/SFS 4.4.15

    YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    SFS 4.4.15 No Planned 2Supported

    (V20L15 or later)

    LP10000/LP10000DC/LP1050/LP1050DC/

    LP1050Ex/LP10000ExDC6.30g Yes

    Supported(V11L80 or later)

    Supported(V20L43 or later)

    LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150

    6.30g YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    QLA2340/QLA2342/QLA2460/QLA2462/QLE2460/QLE2462/

    QLE2464V5.05 Yes

    Supported(V11L80 or later)

    Supported(V20L43 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    SFS 4.4.15 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    SFS 4.4.15 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    SFS 4.4.15 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    SFS 4.4.15 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    SFS 4.4.15 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    SFS 4.4.15 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    VCS 5.1(including Oracle RAC)

    Note 1

    When using VxVM 5.1, the maximum number of LUNs is 128 per server.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.

    Instruction for use

    VxVM 5.1

    MPxIO

    PCI-Express

    Driver Version

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    HBA Switch Path Failover

    SUN Fire

    Bus Cluster System

    When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.Solaris 9 for Sun Cluster 3.2 should be version "9/05" only.

    Sun Cluster 3.2

    When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM(SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.Please apply Solaris patch 125511-02/125517-03/126047-06.

    SAN boot

    Model

    Solaris system OS

    Direct/via switch

    PCI-bus/PCI-Express

    PCI-bus/PCI-Express

    PCI-bus/PCI-Express

    via switch

    ConnectedType

    Solaris 9 OS

    Direct/via switch

    PCI-Express

    PCI-bus/PCI-Express

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Sun Cluster 3.2

    Direct

    Sun Cluster 3.2

    When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM(SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.Please apply Solaris patch 125511-02/125517-03/126047-06.Solaris 9 for Sun Cluster 3.2 should be version "9/05" only.

    Solaris 8 OSDirect/

    via switch

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    MPxIO

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    MPxIO

  • 10/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-EM4-Z/SG-XPCI2FC-EM4-Z,

    XSPFC401EU/XSPFC402EU,XAPFC401EU/XAPFC402EU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,

    XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-QF4/SG-XPCI2FC-QF4,

    XSPFC401QU/XSPFC402QU,XAPFC401QU/XAPFC402QU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,

    XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU

    OS bundled Yes Planned 2 Planned 2

    PCI-Express

    SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z

    XSEFC801AUXSEFC802AU

    OS bundled Yes Planned 2 Planned 2

    PCI-Express

    SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z

    XSEFC801QUXSEFC802QU

    OS bundled Yes Planned 2 Planned 2

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI2FC-QF2/SG-XPCI2FC-QF2-Z

    OS bundled YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled - YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI2FC-QF2/SG-XPCI2FC-QF2-Z

    OS bundled YesSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V10L81 or later)Supported

    (V20L11 or later)

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    HBA

    SUN Cluster 3.1

    PCI-bus/PCI-Express

    MPxIO

    PCI-bus/PCI-Express

    Cluster System

    via switch

    -

    Bus Driver Version Switch SAN boot

    Sun Cluster 3.3

    Direct/via switch

    VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    MPxIO

    Direct/via switch

    SUN Fire

    ModelInstruction for use

    PCI-bus/PCI-

    Express

    ConnectedType

    OS

    Solaris patch: PATCH:118833-36 should be applied when using Veritas 5.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    Up to 4-node configuration is supported.When using SunCluster 3.1, volume management is Veritas4.0/4.1-VxVM(SUN-OEM).Apply MP2 RP3 or later patch.

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Solaris10 OS

    Direct/via switch

    MPxIO

    Solaris system Path Failover

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

  • 11/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    OS bundled No Planned 2Supported

    (V20L15 or later)

    SG-XPCI1FC-EM2/SG-XPCI2FC-EM2

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCI1FC-QF2/SG-XPCI1FC-QL2

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    Direct/via switch

    PCI-busQLA2340/QLA2342QLA2460/QLA2462

    5.02 VxVM5.0 NoSupported

    (V10L70 or later)Supported

    (V20L11 or later)

    HBA driver patch: Patch 125166-02 should be applied.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    PCI-bus LP10000/LP10000DC 6.30g VxVM5.0 MP1 No Planned 2Supported

    (V20L15 or later)

    PCI-bus/PCI-Express

    LP11000/LP11002/LPe11000/LPe11002

    6.30g VxVM5.0 MP1 No Planned 2Supported

    (V20L15 or later)

    PCI-Express QLE2560/QLE2562 5.04 VxVM5.0 MP1 No Planned 2Supported

    (V20L15 or later)

    Direct/via switch

    PCI-Express LPe12000/LPe12002 6.30g VxVM5.0 MP1 NoSupported

    (V11L41 or later)Supported

    (V20L11 or later)

    HBA driver patch: Patch 125166-02 should be applied.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    PCI-ExpressLP10000/LP10000DC/LP1050/LP1050DC/

    LP1050Ex/LP10000ExDC6.30g Yes

    Supported(V11L80 or later)

    Supported(V20L43 or later)

    PCI-Express QLE2560/QLE2562 V5.05 YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCI1FC-QF4SG-XPCI2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    PCI-bus/PCI-Express

    via switch

    Bus

    Direct/via switch

    HBA

    Direct

    SUN Fire

    OS ConnectedType

    MPxIO

    Solaris system

    When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.

    Sun Cluster 3.2

    SAN boot Instruction for use

    When using VxVM 5.1, the maximum number of LUNs is 128 per server.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.

    Direct/via switch

    Direct/via switch

    PCI-bus/PCI-Express

    When using Veritas 5, please apply Storage Foundation Enterprise for Oracle RAC 5.0MP1/ MP necessary patch/ MP1 Patch fix file/ MP1 PointPatch, MP1 Rolling Patch2, MP1Rolling Patch3.When using VxVM 5.0, please use ASL(VRTSFJTSYe8k) below.http://www.symantec.com/docs/TECH77672When using VxVM 5.0, the maximum number of LUNs is 128 per server.

    When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM(SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.Please apply Solaris patch 125511-02/125517-03/126047-06.

    VCS 5.0(including Oracle RAC)

    Note 1

    Switch

    11.2.0(GA) and 11.2.0.2 are supported.

    Model

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Solaris10 OS

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Sun Cluster 3.2

    Direct/via switch

    VxVM 5.1

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    VCS 5.1(including Oracle RAC)

    Note 1

    MPxIOOracleRAC11gR2

    (see Instruction for use)

    Path Failover

    PCI-bus/PCI-Express

    Driver Version

    MPxIO

    Cluster System

  • 12/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    x86/x64Solaris 10 OS

    Direct/via switch

    PCI-bus/PCI-Express

    SG-XPCI1/2FC-EM4SG-XPCIE1/2FC-EM4SG-XPCI1/2FC-QF4

    OS bundled

    Refer to"ETERNUS8000Server Support

    Matrix, FC switch"chart for supported

    FC switches.

    MPxIO - NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)Other Companies'Servers (x86/x64)

    ConnectedType

    Bus Driver VersionHBA

    Model

    Cluster System SAN bootPath Failover Instruction for useSolaris system OS Switch

  • 13/141 Copyright 2014 FUJITSU LIMITED

     

    iSCSI native connection

    700/900/1100/2100

    800/1200/2200

    Direct /via switch

    On board LAN OS bundled MPxIO  - NoSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    SP1X7GQ1F/7100479/7100477

    OS bundled MPxIO PCL4.3A20 No Supported(V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    SP1X7HF1F/7100563/7100488

    OS bundled MPxIO PCL4.3A20 No Supported(V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    SE1X7HE3G/1109A-Z/X1109A-Z

    OS bundled MPxIO  - NoSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch On board LAN

    OS bundled MPxIO  - NoSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    SP1X7GQ1F/7100479/7100477

    OS bundled MPxIO PCL4.3A20 No Supported(V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    SP1X7HF1F/7100563/7100488

    OS bundled MPxIO PCL4.3A20 No Supported(V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    SE1X7HE3G/1109A-Z/X1109A-Z

    OS bundled MPxIO  - NoSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Direct /via switch

    On board LAN of serversbelow

    T1000/T2000/T5120/T5220/T5140/T5240/

    T5440/M3000/M4000/M5000/

    M8000/M9000

    OS bundled MPxIO - No Supported(V11L80 or later)Supported

    (V20L41 or later)

    via switch SE0X7GD1F / SE0X7GD2F 3.0 / 4.0 MPxIO PCL 4.2A00 No Supported(V11L80 or later)Supported

    (V20L41 or later)

    via switch SE0X7GQ1F / SE0X7GQ2F 3.0 / 4.0 MPxIO PCL 4.2A00 No Supported(V11L80 or later)Supported

    (V20L41 or later)

    via switch SE0X7HE1F 1.0 MPxIO - No Supported(V11L80 or later)Supported

    (V20L41 or later)

    via switch SESX7XA1F OS bundled MPxIO - No Supported(V11L80 or later)Supported

    (V20L41 or later)

    Direct /via switch

    On board LAN of serversbelow

    T1000/T2000/T5120/T5220/T5140/T5240/

    T5440/M3000/M4000/M5000/

    M8000/M9000

    OS bundled MPxIO - No Supported(V11L80 or later)Supported

    (V20L41 or later)

    Direct /via switch X7280A OS bundled MPxIO - No

    Supported(V11L80 or later)

    Supported(V20L41 or later)

    Direct /via switch X4447A OS bundled MPxIO - No

    Supported(V11L80 or later)

    Supported(V20L41 or later)

    via switch X1027A OS bundled MPxIO - No Supported(V11L80 or later)Supported

    (V20L41 or later)

    Direct /via switch X7280A OS bundled MPxIO - No

    Supported(V11L80 or later)

    Supported(V20L41 or later)

    Direct /via switch X4447A OS bundled MPxIO - No

    Supported(V11L80 or later)

    Supported(V20L41 or later)

    via switch X1027A OS bundled MPxIO - No Supported(V11L80 or later)Supported

    (V20L41 or later)

    Direct /via switch X4446-A OS bundled MPxIO - No

    Supported(V11L80 or later)

    Supported(V20L50 or later)

    Direct /via switch

    Intel Pro/1000PTIntel Pro/1000MT

    OS bundled MPxIO - NoSupported

    (V11L80 or later)Supported

    (V20L50 or later)

    Fujitsu M10

    Solaris 11 OS

    Solaris iSCSI connection [Edition 133 : March 6, 2014]

    - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.

    Model

    Instruction for uses

    Notes - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers.

    Solarissystem

    Connectiontype

    HBA Cluster System iSCSI BootDriver version Path FailoverOS

    Please apply the following patch- 143646-16 or later

    SPARC Enterprise(Fujitsu)

    (China, Korea,Hong Kong only)

    Solaris 10 OS10/09 or later

    Other Companies'Servers (x86/x64)

    x86/x64Solaris 10 OS

    Update 8 or later

    SPARC Enterprise(Fujitsu brand)

    (Region other thanabove)

    SPARC ServersSPARC Enterprise

    (Sun brand)

    Solaris 10 OS10/09 or later

    SUN Fire Solaris 10 OS10/09 or later

    Please use Oracle Solaris 11.1 or later.

    Solaris 10 OS Please use Oracle Solaris 10 OS 1/13 or later.

    Please apply the following patch- 143645-16 or later

    Please apply the following patch- 143645-16 or later

    Please apply the following patch- 143645-16 or later

  • 14/141 Copyright 2014 FUJITSU LIMITED

     

    FC-FCoE(switch) connection : This sheet is for the system of connection of Server(CNA card) -- FCoE switch - ETERNUS FC port.

    via Switch(Brocade 8000 or

    Brocade FCoE bladeonly,

    via switch OS isv6.3.1a)

    via Switch(Brocade6730、

    NOS v2.1.1)

    via SwitchCisco

    Nexus5000Model name BIOS version/

    EFI driver versionFirmware version FC and FCoE Driver

    version700/900/

    1100/2100800/1200/

    2200

    Supported Supported SupportedSP1X7FBR2F/SP1X7FBS2F

    7101673/7101674(7101677/7101678)

    - - OS bundled MPxIO - No Planned 2Supported

    (V20L86 or later)

    Supported Supported SupportedSP1X7FBR2F/SP1X7FBS2F

    7101683/7101684(7101687/7101688)

    - - OS bundled MPxIO - No Planned 2Supported

    (V20L86 or later)

    Supported Supported Planned 2

    SE0X7EC12F/SE0X7EF12F/SG-PCIEFCOE2-Q-TA/SG-PCIEFCOE2-Q-SR/

    7105382/7105381/QLE8140/QLE8142/QLE8150/QLE8152

    - - OS bundled MPxIO - NoSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Supported Supported SupportedSP1X7FBR2F/SP1X7FBS2F

    7101673/7101674(7101677/7101678)

    - - OS bundled MPxIO - No Planned 2Supported

    (V20L86 or later)

    Supported Supported SupportedSP1X7FBR2F/SP1X7FBS2F

    7101683/7101684(7101687/7101688)

    - - OS bundled MPxIO - No Planned 2Supported

    (V20L86 or later)

    Supported Supported Planned 2

    SE0X7EC12F/SE0X7EF12F/SG-PCIEFCOE2-Q-TA/SG-PCIEFCOE2-Q-SR/

    7105382/7105381/QLE8140/QLE8142/QLE8150/QLE8152

    - - OS bundled MPxIO - NoSupported

    (V11L91 or later)Supported

    (V20L71 or later)

    Supported Supported Supported7101673/7101674

    (+7101677/7101678)- - OS bundled MPxIO - No Planned 2

    Supported(V20L86 or later)

    Supported Supported Supported7101683/7101684

    (+7101687/7101688)- - OS bundled MPxIO - No Planned 2

    Supported(V20L86 or later)

    Supported Supported Supported7101681/7101682

    (+7101677/7101678)- - OS bundled MPxIO - No Planned 2

    Supported(V20L86 or later)

    Supported Supported Supported7101689/7101690

    (+7101687/7101688)- - OS bundled MPxIO - No Planned 2

    Supported(V20L86 or later)

    Supported Supported Planned 2SG-XPCIEFCOE2-Q-SR,

    QLE8140/QLE8142- - OS bundled MPxIO - No Planned 2

    Supported(V20L71 or later)

    Supported Supported Planned 2SG-XPCIEFCOE2-Q-TA

    QLE8150/QLE8152- - OS bundled MPxIO - No Planned 2

    Supported(V20L71 or later)

    Supported Supported Supported7101673/7101674

    (+7101677/7101678)- - OS bundled MPxIO - No

    Supported(V20L86 or later)

    Supported(V10L52 or later)

    Supported Supported Supported7101683/7101684

    (+7101687/7101688)- - OS bundled MPxIO - No

    Supported(V20L86 or later)

    Supported(V10L52 or later)

    Supported Supported Supported7101681/7101682

    (+7101677/7101678)- - OS bundled MPxIO - No

    Supported(V20L86 or later)

    Supported(V10L52 or later)

    Supported Supported Supported7101689/7101690

    (+7101687/7101688)- - OS bundled MPxIO - No

    Supported(V20L86 or later)

    Supported(V10L52 or later)

    Supported Planned 2 Planned 2SG-XPCIEFCOE2-Q-SR,

    QLE8140/QLE8142- - OS bundled MPxIO - No

    Supported(V11L90 or later)

    Supported(V20L70 or later)

    Please use Solaris 10 9/10 or later.

    Supported Planned 2 Planned 2SG-XPCIEFCOE2-Q-TA

    QLE8150/QLE8152- - OS bundled MPxIO - No

    Supported(V11L90 or later)

    Supported(V20L70 or later)

    Please use Solaris 10 9/10 or later.

    Cluster system

    Please use Solaris 11 11/11 or later.

    Solaris 10 OS

    Solaris 11 OS

    Please use Oracle Solaris 11.1 or later.

    Please use Oracle Solaris 10 OS 1/13 or later.

    Solaris FC-FCoE(switch) connection [Edition 132 : February 19, 2014]Note

    Solaris system OS

    Connection type HBA

    Instruction for usesSAN boot

    Model

    Path Failover

    Fujitsu M10

    Solaris 11 OS Please use Oracle Solaris 11.1 or later.

    Please use Oracle Solaris 10 OS 1/13 or later.Solaris 10 OS

    SPARC ServersSPARC Enterprise

  • 15/141 Copyright 2014 FUJITSU LIMITED

    - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.

    700/900/1100/2100

    800/1200/2200

    A5158A/A6795A OS bundled - NoSupported

    (V11L52 or later)Supported

    (V20L11 or later)

    A6826A OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    A6826A OS bundled YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    A6795A OS bundled YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    A9782A/A9784A OS bundled YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V10L64 or later)Supported

    (V20L11 or later)

    AB465A OS bundled YesSupported

    (V10L64 or later)Supported

    (V20L11 or later)

    AD193A/AD194A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD300A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD299A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD355A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V10L64 or later)Supported

    (V20L11 or later)

    A6826A OS bundled YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    A6795A OS bundled YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)

    A9782A/A9784A OS bundled YesSupported

    (V10L24 or later)Supported

    (V20L11 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V10L64 or later)Supported

    (V20L11 or later)

    AB465A OS bundled YesSupported

    (V10L64 or later)Supported

    (V20L11 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V10L64 or later)Supported

    (V20L11 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    A6826A OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    A6795A OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    AD193A/AD194A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD300A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD299A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD355A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    HP-UX FC connection [Edition 132 : February 19, 2014]

    SAN bootDriver Version

    via switch

    VxVM 4.1

    When connecting ETERNUS8000 to HP-UX server, especially when using HP's softwaremirroring function, please contact to Fujitsu Storage system.

    When connecting ETERNUS8000 to HP-UX, the maximum number of LUNs is up to 128.

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    HP-UX11iv1

    Direct/via switch

    HP-UX System OS ConnectedType

    HP 9000 Serverrp series

    SuperDomeHP Integrity Server

    rx seriesSuperDome

    Model

    VCS 4.1(including Oracle RAC)

    Note 1

    ServiceguardA.11.16

    PCI-bus

    Cluster System

    - Veritas products' drivers for ETERNUS8000 can be downloaded from the following website. The installation instructions are also described on the website. - for HP-UX: VxVM 4.0 & 4.1 - http://entkb.symantec.com/security/output/a284354.html

    Instruction for use

    Notes

    Switch Path Failover

    Direct/via switch

    PV-Links(OS bundled)

    ServiceguardA.11.18

    HBA

    PV-Links(OS bundled)

    PCI-bus

    VxVM 5.0

    Bus

    VCS 5.0(including Oracle RAC)

    Note 1

    Refer to"ETERNUS8000Server Support

    Matrix, FC switch"chart for

    supported FCswitches.

    via switch

    HP-UX11iv2

    (HP-UX11.23)

  • 16/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    A6826A OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    A6795A OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    AD193A/AD194A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD300A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AH400A/AH401A OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    AH402A/AH403A OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    451871-B21(QMH2562) OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    456972-B21(LPe1205) OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    A5158A OS bundled YesSupported

    (V11L52 or later)Supported

    (V20L11 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    A6826A OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    A6795A OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    AD299A OS bundled Yes Planned 1Supported

    (V20L11 or later)

    AD300A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AD355A OS bundled Yes Planned 1Supported

    (V20L11 or later)

    AD193A/AD194A OS bundled YesSupported

    (V11L30 or later)Supported

    (V20L11 or later)

    AH400A/AH401A OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    AH402A/AH403A OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V11L23 or later)Supported

    (V20L11 or later)

    451871-B21(QMH2562) OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)

    403621-B21(LPe1105) OS bundled Yes Planned 1Supported

    (V20L11 or later)

    456972-B21(LPe1205) OS bundled YesSupported

    (V11L71 or later)Supported

    (V20L30 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD193A/AD194A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD300A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD299A/AD355A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AH400A/AH401A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AH402A/AH403A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    451871-B21(QMH2562) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    403621-B21(LPe1105) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    456972-B21(LPe1205) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    OS HBA

    via switch

    PCI-bus/PCI-Express

    Native Multipath

    ServiceguardA.11.18

    /ServiceguardA.11.19

    /ServiceguardA.11.20

    VCS 5.0(including Oracle RAC)

    Note 1

    PV-Links

    ServiceguardA.11.18

    /ServiceguardA.11.19

    /ServiceguardA.11.20

    SwitchDriver Version

    ModelInstruction for useHP-UX System Cluster System SAN boot

    VxVM 5.0 When connecting ETERNUS8000 series to HP-UX, then the maximum number of LUNs isup to 128.

    When connecting ETERNUS8000 to HP-UX server, especially when using HP's softwaremirroring function, please contact to Fujitsu Storage system.

    When connecting ETERNUS8000 to HP-UX, the maximum number of LUNs is up to 128.

    Serviceguard A.11.19/A.11.20 are only supported by model 800/1200/2200.

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Path FailoverConnected

    TypeBus

    HP-UX11iv3

    Refer to"ETERNUS8000Server Support

    Matrix, FC switch"chart for

    supported FCswitches.

    Direct/via switch

    HP 9000 Serverrp series

    SuperDomeHP Integrity Server

    rx seriesSuperDome

  • 17/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    A6826A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    A6795A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD193A/AD194A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD299A/AD355A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD300A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AH400A/AH401A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AH402A/AH403A OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    403619-B21(QMH2462) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    451871-B21(QMH2562) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    403621-B21(LPe1105) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    456972-B21(LPe1205) OS bundled YesSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    A6826A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    A6795A OS bundled No Planned 2 Planned 2

    AD193A/AD194A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    AB378A/AB378B/AB379A/AB379B

    OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    AD299A/AD355A OS bundled No Planned 2 Planned 2

    AD300A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L60 or later)

    AH400A/AH401A OS bundled No Planned 2 Planned 2

    AH402A/AH403A OS bundled No Planned 2 Planned 2

    A6826A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    A6795A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)AB378A/AB378B/AB379A/AB379B

    OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD193A/AD194A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD300A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AD299A/AD355A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AH400A/AH401A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    AH402A/AH403A OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    403619-B21(QMH2462) OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    451871-B21(QMH2562) OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    403621-B21(LPe1105) OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    456972-B21(LPe1205) OS bundled NoSupported

    (V11L80 or later)Supported

    (V20L43 or later)

    Driver Version

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    Switch Path Failover Cluster System SAN bootHP-UX SystemModel

    Instruction for use

    When connecting with HP-UX, the maximum number of LUNs is up to 128.

    Bus HBA

    -Native Multipath

    Refer to"ETERNUS8000Server Support

    Matrix, FC switch"chart for

    supported FCswitches.

    Refer to"ETERNUS8000Server Support

    Matrix, FC switch"chart for

    supported FCswitches.

    OS

    HP 9000 Serverrp series

    SuperDomeHP Integrity Server

    rx seriesSuperDome

    PCI-bus/PCI-Express

    via switchPCI-bus/

    PCI-Express

    Refer to"ETERNUS8000Server Support

    Matrix, FC switch"chart for

    supported FCswitches.

    HP-UX11iv3(IPF)

    +IntegrityVM4.1

    Direct/via switch

    PCI-bus/PCI-Express

    ConnectedType

    VxVM 5.1 VCS 5.1

    HP-UX11iv3

    Direct/via switch

    VxVM 5.0.1VCS 5.0.1

    (including Oracle RAC)Note 1

  • 18/141 Copyright 2014 FUJITSU LIMITED

    Inquiries : [email protected]

    - AIX MPIO 2.0.2 is no longer available from January 12, 2010. Please use EMPD 2. - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.

    700/900/1100/2100

    800/1200/2200

    AIX 5.1Direct/

    via switchPCI-bus 6228/6239 OS bundled

    EMPD1.0.4

    - NoSupported

    (V11L52 or later)Supported

    (V20L11 or later)

    AIX 5.2/5.36228/6239/5716/1977

    OS bundledEMPD1.0.4

    HACMP 5.3 NoSupported

    (V10L70 or later)Supported

    (V20L11 or later)

    5758/19055759/1910

    OS bundled HACMP5.3 NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    5716/1977 OS bundled HACMP5.3 NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    6239 OS bundled HACMP5.3 NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)When using 6239 (Firmware level: 1.92a1) on AIX 5.2, please apply APAR(IZ05479).

    via switch 5716/1977 OS bundled VxVM 4.0VCS 4.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    via switch5758/19055759/1910

    OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    5716/1977 OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    6239 OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    5716/1977 OS bundled No Planned 2 Planned 2

    5758/19055759/1910

    OS bundled No Planned 2 Planned 2

    AIX FC connection [Edition 116 : January 25, 2013]

    HACMP 5.4

    Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 4096 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.

    EMPD 2.0.0

    IBM RS/6000SP/xx/xx/xxIBM P series

    IBM System pIBM PowerSystems

    via switch

    AIX 5.2

    Direct/via switch

    Notes

    AIX System Switch Path Failover

    Refer to"ETERNUS8000Server Support

    Matrix, FCswitch" chart forsupported FC

    switches.

    PCI-Bus

    Direct/via switch PCI-Bus

    OS ConnectedType

    Bus

    When connecting ETERNUS8000 to IBM AIX server, please contact to Fujitsu Storagesystem.

    ETERNUS MPIO2.0.0 or later

    - Veritas products' drivers for ETERNUS8000 can be downloaded from the following website. The installation instructions are also described on the website. - for AIX: VxVM 4.0 - http://entsupport.symantec.com/docs/a285827

    HBA Driver Version

    VxVM 5.0VCS 5.0

    (including Oracle RAC)Note 1

    When using VxVM 5.0, the maximum number of LUNs is 128.

    When using 6239 (Firmware level: 1.92a1) on AIX 5.2, please apply APAR(IZ05479).

    Instruction for useSAN boot

    Model

    Cluster System

  • 19/141 Copyright 2014 FUJITSU LIMITED

    700/900/1100/2100

    800/1200/2200

    5758/19055759/1910

    OS bundled HACMP5.4 NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    5716/1977 OS bundled HACMP 5.4 NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    6239 OS bundled HACMP5.4 NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    6228 OS bundled HACMP5.4 NoSupported

    (V11L52 or later)Supported

    (V20L11 or later)

    - NoSupported

    (V10L53 or later)Supported

    (V20L11 or later)VCS 4.0

    (including Oracle RAC)Note 1

    NoSupported

    (V10L62 or later)Supported

    (V20L11 or later)

    6239 OS bundled - NoSupported

    (V10L53 or later)Supported

    (V20L11 or later)

    6228 OS bundledVCS 4.0

    (including Oracle RAC)Note 1

    NoSupported

    (V11L52 or later)Supported

    (V20L11 or later)

    5758/19055759/1910

    OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    5716/1977 OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    6239 OS bundled NoSupported

    (V11L12 or later)Supported

    (V20L11 or later)

    via switch PCI-Express 5735 OS bundled NoSupported

    (V11L71 or later)Supported

    (V20L20 or later)

    Direct/via switch

    PCI-Express 5773/5774 OS bundledETERNUS MPIO

    2.0.1 or laterHACMP 5.4 No

    Supported(V11L52 or later)

    Supported(V20L12 or later)

    When using HACMP5.4, please apply APAR(IY87247, IY98754) and ifix(IZ05530).

    via switch PCI-Express 5735 OS bundledETERNUS MPIO

    2.0.2 or laterHACMP 5.