ETERNUS JX60

Technical Product Introduction

0 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 2: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Highlights

The ETERNUS JX60 passive

storage subsystem accommodates

up to 240 HDDs

3.5" SAS 2.0 Nearline SAS 7200 rpm,

max. storage capacity 960 TB 1)

One or two 6 Gbit/s SAS interfaces for host server connection

A maximum of two enclosures can be daisy-chained

Can be used as a JBOD or RAID system

RAID functionality provided by the controller in the host server

Certified for Windows 2012 R2 Storage Spaces

1 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

1) At the time of publication using four enclosures fully populated with 4 TB disks

Page 3: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Overview

Disk bays per enclosure 60

Disk technology SAS 2.0

Max. number of enclosures per server 4

When both channels of the HBA/RAID Controller are used

I/O Modules (IOM) 1 or 2

Power Supply Units (PSU) 4

Fan Expander Modules (FEM) 2

Maximum number of host servers 1 (2 in cluster config.)

Height unit standard 4 U

2 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 4: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Technical Overview

Technical Product Introduction ETERNUS JX60 Copyright Fujitsu, Release June 2014 3

Page 5: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Shipment Contents

4 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

ETERNUS JX60

Setup and Installation poster

Rackmount kit

Drive Enclosure

(with front bezel mounted)

4 power cords

2 AC cables 2.5 m

2 AC cables 4.0 m

Safety Manual

Rack installation tool

(two pieces, fitted

underneath the system)

Page 6: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Rack Mount Kit

5 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Flap Bracket

Cable Management Arm

Screws

Left rail

Right rail

Cable ties

(black/green) Aluminium blocks

Page 7: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Unpacking and Packing

Always retain the original packaging of the storage subsystem for possible

further transport

The storage subsystem should be transported only in its original

packaging or other suitable packaging for protecting it against transport

damage

Please note that the above is also valid for

spare parts, including defective disks

Please observe the acclimatization times

before connecting the system to mains

power

6 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Temperature

difference °C

Min. acclimatization

time (hours)

5 3

10 5

15 7

20 8

25 9

30 10

Page 8: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Rack Installation

For complete instructions please refer to the Operating Manual and/or to

the Setup and Installation poster supplied with the system

7 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Rack installation tool

Minimum required rack depth for the

installation of the JX60 is 1050 mm

Removing the rack installation tool

Page 9: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

8 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip RackInstallation.wmv

Page 10: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Rack Mount

It is strongly recommended to fit an anti-tilt bracket on the rack during the

installation and to use it always when an enclosure is pulled out from the

rack

The supplied Cable Management Arm,

Flap Bracket and cable ties provide

appropriate cable management

9 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 11: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Cabling

Two types of cables available

SAS cables for host connection

• Available in lengths of 3 and 6 meters (ca. 10 and 20 feet)

• Host SAS cables have two different types of connectors

• Mini SAS connector for the host connection (SFF8088)

• Mini SAS HD connector for connecting to the JX60 (SFF8644)

SAS cables for cascading

2.5, 3.5 and 6 meters (ca. 8, 12 and 20 feet)

Both cable ends equipped with the same

connector type

Cables are connected to the JX60 with

the cable tab on the underside

10 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

SFF8088

SFF8644

Page 12: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

11 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip Cabling.wmv

Page 13: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Installation

For complete step-by-step installation instructions please refer to the

Setup and Installation poster or the Operating Manual

Unpack the storage subsystem

Mount the storage subsystem in the rack

Cabling

Connect the system to mains voltage

• Ensure that at least two PSUs of the JX60 and one PSU of the host server are connected with the

same phase

• For phase redundancy the PSUs of the JX60 must be pairwise connected to two different phases or

rack power circuits

Switch on the host server

• Fitted with a SAS RAID Controller or SAS HBA

• Only released SAS RAID / HBA are supported, please see MatrixEP for reference

• The storage subsystem switches automatically on when SAS signal is detected

12 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 14: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Exterior View Front

13 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

DE ID

Sequential Enclosure number

between 01 and 04

Identify LED

Blinking blue = Locate function activated

using ServerView

Power LED

Green = DC power supply is

in normal status

Fault LED

Amber = The system is in

warning or error status

Disk Status LED

Green or blinking green = Disk is in

normal status

Amber = Disk is in error status

OR

Locate functionality enabled with ServerView Disk Activity Panel Operation Panel

Identify LED

Power LED

Fault LED Disk Status LED

DE ID

Page 15: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

14 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip ExteriorViewFront.wmv

Page 16: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Exterior View Rear

15 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

FEM#1

PSU#1

PSU#3

IOM#1

FEM#0

PSU#0

PSU#2

IOM#0

SAS IN SAS OUT SAS IN SAS OUT

FEM = Fan Expander Module

IOM = I/O Module

PSU = Power Supply Unit

Page 17: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

16 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip ExteriorViewRear.wmv

Page 18: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

I/O Module (IOM)

Connects the JX60 with the host server

One or two IOMs per enclosure

Supports 6 Gb/s host transfer rate

Hot replaceable

Requires dual IOM configuration

• Always use proper ESD protection (wrist strap) during replacement to avoid causing damage to the

unit

• Before removal it must be ensured that all server data transfer to the failed unit is stopped to avoid

loss of data

• For complete replacement instructions please refer to the Operating Manual or the Service

Supplement

17 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 19: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

IOM Exterior View

18 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

In Link

Fault LED

Out Link

Fault LED

In Link LED SAS In Port SAS Out Port Out Link LED Ready LED Fault LED Identify LED

Eject lever

locking latch

Eject lever In Link LED

Green = Link established

In Link Fault LED

Amber = The link between the In Port

and the source is in error status

Out Link LED

Green = Link established

Out Link Fault LED

Amber = The link between the Out Port

and the destination is in error status

Fault LED

Amber = The I/O module is

in error status

Ready LED

Green = The I/O module is

in normal status

Identify LED

Blinking blue = Locate function

activated using

ServerView

Eject lever locking latch

Need to be pushed sideways to

be able to use the eject levers

Eject lever

Pulled outward to remove the module

Page 20: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

19 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip IOMExteriorView.wmv

Page 21: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Power Supply Unit (PSU)

Four redundant 80 Plus Gold (92%) PSUs as standard

It is recommended to use separate power sources for a pair of PSUs Two phases or two different circuits of the rack installation

Recommended to have at least two of the JX60 PSUs and one of the host server PSUs

connected to the same phase

Hot Plug replaceable Always use proper ESD protection (wrist strap) during replacement to avoid causing

damage to the unit

Do not leave removed for longer than 5 minutes to ensure normal cooling of the system

For complete replacement instructions please refer to the Operating Manual or the

Service Supplement

No power on/off switch, system is switched on and off by detection of the

SAS signal

20 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 22: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

PSU Exterior View

21 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Fault LED Power LED AC Missing LED Fan Fail LED Power cable

locking strap

Fault LED

Amber = DC power is not supplied by the PSU

Power LED

Green = AC power is supplied to the PSU

AC Missing LED

Amber = AC power is not supplied to this PSU but to another PSU

Fan Fail LED

Amber = The PSU or the fan in the PSU is in error status

Power cable locking strap

Can be applied to prevent accidental removal

of power cable

Page 23: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

22 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip PSUExteriorView.wmv

Page 24: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Fan Expander Module (FEM)

Contains two SAS Expanders that provide the system internal interface

between the IOM and the disks

Two integrated cooling fans

Hot Plug replaceable

Requires dual IOM configuration

• Always use proper ESD protection (wrist strap) during replacement to avoid causing damage to the

unit

• When replacing, do not leave removed for longer than 5 minutes to ensure normal cooling of the

system

• For complete replacement instructions please refer to the Operating Manual or the Service

Supplement

23 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 25: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

FEM Exterior View

24 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Fault LED Ready LED

Fault LED

Amber = The module is in error status

Ready LED

Green = The module is in normal status

Page 26: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Module Overview

25 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Rear of the system

IOM

(I/O Module)

FEM

(Fan Expander

Module)

Cable Management Arm

PSU

(Power Supply Unit)

Flap Bracket

Page 27: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Hard Disk Drives (1)

Maximum of 60 disks per enclosure

1) Nearline SAS

2.0, 4 TB / 3 TB / 2 TB, 7200 rpm, 3.5"

Different capacities can be mixed in

the same enclosure

Drives of an ETERNUS DX High

Density Drive Enclosure are not

compatible with the disks of the JX60

All disk slots must be fitted either

with a disk or a dummy drive

26 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

1) All capacities at the time of publication

Front

Disk numbering from top left to bottom right

Page 28: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Hard Disk Drives (2)

To access the disks

Release the locking

latches on each side

of the front panel

Pull out the enclosure

Release the green

cover locking latches

and swing the cover

to the left

27 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Fault LED

Amber = The hard disk is in error status

OR

Locate functionality

enabled with ServerView Hard Disk Frame

Rear

Front Locking lever

Fault LED

Page 29: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Hard Disk Drives (3)

Hot replacement supported if the disk belongs to a faultless and fault-

tolerant RAID Group of the host server RAID controller

Replacement allowed only when the disk is inactive

• Or marked defective in the ServerView RAID Manager

First pull the disk out only to disconnect it, then wait 60 seconds for the Host Bus Adapter

to recognize the removal and to let the disk spin down

• After removing from the disk slot, do not leave a disk removed for longer than 5 minutes to ensure

normal cooling of the system

28 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 30: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

29 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip ReplaceDisk.wmv

Page 31: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

SAS RAID Controller / Host Bus Adapter

LSI MegaRAID SAS9286CV-8e

x8 lane PCIe 3.0, Full Height and Low Profile, 1 GB cache with ECC, 8 external ports with

up to 6.0 Gb/s transfer rate per port

Supported RAID levels

• 0, 1, 10, 5, 50, 6, 60

Supports Dedicated and Global Hot Spare

ServerView RAID Manager for RAID configuration

LSI SAS9200-8e

x8 lane PCIe 2.0, Full Height and Low Profile

6 Gb/s SAS 2.0, 8 external ports

For up-to-date list of qualified PRIMERGY servers, RAID controllers and

SAS HBAs please refer to the MatrixEP tool

30 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 32: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Host Server Connection (1)

Basic RAID controller / HBA configuration

Redundant configuration 1)

31 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Second shelf optional

1) Not supported for RAID Controller at initial product release, please refer to MatrixEP for up-to-date status

Page 33: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Identification

The system serial number can be found on the

extractable tab in the front of the system and

on the identification label located on the

system cover in the rear of the system

For system identification, the

first five digits of the serial

number are: JWXTD

32 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Rear

Front

Location of the identification label

Page 34: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

33 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip Identification.wmv

Page 35: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Management

Fujitsu ServerView support

The Agents from ServerView Suite DVD are required on the connected server

Uses SES1) protocol over in-band SAS for the monitoring features

• Module status

• IOM, PSU, FEM

• Module and system temperatures

• Hard disk status

ServerView RAID Manager

• V5.8.8 or later

34 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

1) SCSI Enclosure Services

Page 36: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

35 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip Management.wmv

Page 37: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

OS Support

Supported Operating Systems 1)

Windows Server • 2012 R2, Server 2012, 2008 SP2, 2008 SP2 (x64), 2008 R2 (x64)

SuSE Linux Enterprise Server • 10 SP4, 10 SP4 EM64T, 11 SP3, 11 SP3 EM64T

RedHat Enterprise Linux • 5 U10, 5 U10 EM64T, 6 U5 x86, 6 U5 x86_64

VMware vSphere • 5.1 Update 2, 5.5 Update 1

For up-to-date list of supported Operating Systems please refer to the MatrixEP

tool

The host server can be booted from the ETERNUS JX60 The boot functionality is PRIMERGY dependent and is limited to certain HBAs and slots, please refer to

the respective PRIMERGY documentation

36 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

1) At the time of publication

Page 38: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Manuals and Support Information

Operating Manual

Features, technical data, troubleshooting, installation/removal of all Hot Plug components

http://support.ts.fujitsu.com/manuals/

or

https://partners.ts.fujitsu.com/com/service/ps/Storage/disc/ETERNUS_JX/JX60/Pages/def

ault.aspx

FTS_ETERNUSJX60OperatingManual_EditionJune2014_1110971.PDF

Service Supplement

Replacing components

https://partners.ts.fujitsu.com/com/service/ps/Storage/disc/ETERNUS_JX/jx60/Pages/defa

ult.aspx

tm-JX60-SS-en.pdf

37 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 40: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Service and Support

Technical Product Introduction ETERNUS JX60 Copyright Fujitsu, Release June 2014 39

Page 41: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Electrostatic Precautions

Discharge static electricity from your body (for example by touching a grounded

metal object) before handling modules containing electrostatic sensitive

components

The equipment and tools you use must be free of static charge

Remove the power plug before installing or removing modules containing

electrostatic-sensitive components

Only hold modules containing electrostatic-sensitive components by their edges

Do not touch any of the pins or track conductors on a module containing

electrostatic-sensitive components

Use a grounding strap designed for the purpose, to connect you to the system unit

as you install the modules

Place all components on a static-safe base

40 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 42: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

CRUs

Customer Replaceable Units

Hot replaceable

• Hard Disk Drive

For detailed replacement instructions refer to the Operating Manual

41 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 43: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

FRUs

Field Replaceable Units

Hot replaceable FRUs

• Input/Output Module (IOM)

• Pre-requisites; Two IOMs, Single server connection, Path redundancy

• Fan Expander Module (FEM)

• Pre-requisites; Two IOMs, Single server connection, Path redundancy

• Power Supply Unit (PSU)

• Hard Disk Drive

Not hot replaceable FRUs

• Operating Panel

• Disk Activity Panel

• Mid-plane and Back-plane

• To replace the Mid-plane or Back-plane the complete housing needs to be replaced

For detailed replacement instructions refer to the Service Supplement 42 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Page 44: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

43 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60

Place holder for video clip ReplaceModule.wmv

Page 45: ETERNUS JX60 - Fujitsu...IOM Exterior View Technical Product Introduction ETERNUS JX60 18 Copyright Fujitsu, Release June 2014 In Link Fault LED Out Link Fault LED In Link LED SAS

Support Tools

MatrixEP

Supported servers and RAID controllers

https://partners.ts.fujitsu.com/com/products/servers/primergy/conftools/matrixep/Pages/de

fault.aspx

or

http://ts.fujitsu.com/matrixep

Spare part list ERSIN

https://partners.ts.fujitsu.com/com/service/general/service-

spares/ERSIN/Pages/default.aspx

Product class for the ETERNUS JX60

• PR85-FTS STORAGE GLOBAL

44 Copyright Fujitsu, Release June 2014 Technical Product Introduction ETERNUS JX60