41

ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure
Page 2: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure
Page 3: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

P

Preface

This document briefly explains the operations that need to be performed by the user in order toconnect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, orETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system to aPRIMERGY or PRIMEQUEST 1000 series running VMware® ESX via a Fibre Channel interface.

This document should be used in conjunction with any other applicable user manuals, such asthose for the ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, orETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system, server,OS, Fibre Channel cards, drivers, etc.This document references the following documents:

� Server Support Matrix� ETERNUS Disk storage systems Server Connection Guide (Fibre Channel)

for VMware® ESX

Also note that in this document the ETERNUS2000 models 100 and 200, ETERNUS4000models 300, 400, 500, and 600, and ETERNUS8000 models 700, 800, 900, 1100, 1200, 2100,and 2200 Disk storage systems are collectively referred to as ETERNUS Disk storage systems.

Sixth EditionDecember 2010

The Contents and Structure of this Manual

This document is composed of the following three chapters and an appendix.

� Chapter 1 Workflow

This describes how to set up the server and Fujitsu Fibre Channel card driver whenconnecting the ETERNUS Disk storage systems to the server via Fujitsu Fibre Channelcards.

� Chapter 2 For PRIMERGY

This describes how to install and set up the Fibre Channel cards and server.

� Chapter 3 For PRIMEQUEST 1000 Series

This describes how to install and set up the Fibre Channel cards and server.

A WWN instance management table for the server which is used when checking the Fibre Chan-nel cards is described in the appendix.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

3 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 4: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Preface

P

Safe Use of this Product

■ Using this manual

This manual contains important information to ensure the safe use of this product. Be sure tothoroughly read and understand its contents before using the product. After reading, store thismanual in a safe place for future reference.FUJITSU has made every effort to ensure the safety of the users and other personnel, and toprevent property damage. When using this product, carefully follow the instructions described inthis manual.

Acknowledgments

� VMware, VMware logos, Virtual SMP, and VMotion are either registered trademarks or trademarks of VMware, Inc. in the U.S. and/or other countries.

� Emulex is a trademark of Emulex Corp.� QLogic is a trademark of QLogic Corp.� The company names, product names and service names mentioned in this document are

registered trademarks or trademarks of their respective companies.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

4 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 5: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Preface

P

Naming Conventions

■ Product names

� "VMware ESX" represents the following products:- VMware vSphere (ESX 4.1, ESXi 4.1, ESX 4.0, ESXi 4.0)- VMware Infrastructure 3 (ESX 3.5, ESXi 3.5)- VMware ESX Server 2.5.x

■ Other names

� "Channel Adapter" (CA) refers to a Fibre Channel interface module used in the ETERNUS Disk storage systems to connect to the server.

� "Fibre Channel card" refers to the Fibre Channel interface module normally used in the server. A "Host Bus Adapter" (HBA) or "Channel Adapter" (CA) may be used instead, depending on the server.

� "VMware ESX" refers to "VMware vSphere", "VMware Infrastructure 3", and "VMware ESX Server 2.5.x", which are datacenter solutions from VMware that virtualize the storage and networking system.

� The name "VMware vSphere", "VMware Infrastructure 3", and "VMware ESX Server 2.5.x" are used in specific datacenter sections.

� Italics are used to show variables such as values and characters that appear in command parameters and output examples.

Screen shot(s) reprinted with permission from Microsoft Corporation.

Copyright 2010 FUJITSU LIMITED

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

5 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 6: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

6 Copyright 2010 FUJITSU LIMITED

P3AM-2862-06ENZ0

Contents

Chapter 1 Workflow ...................................................................................7

Chapter 2 For PRIMERGY .........................................................................92.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards ................... 9

2.1.1 Setting Up the Fibre Channel Card ............................................................................................. 92.1.2 Setting Up SAN Boot ................................................................................................................. 112.1.3 Installing the VMware ESX Server ............................................................................................ 172.1.4 Setting Up the Fibre Channel Card Driver ................................................................................. 17

2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards ........................ 212.2.1 Setting Up the Fibre Channel Card ........................................................................................... 212.2.2 Setting Up SAN Boot ................................................................................................................. 262.2.3 Setting the Selectable Boot ....................................................................................................... 282.2.4 Installing the VMware ESX Server ............................................................................................ 302.2.5 Setting Up the Fibre Channel Card BIOS .................................................................................. 302.2.6 Setting Up the Fibre Channel Card Driver ................................................................................. 32

Chapter 3 For PRIMEQUEST 1000 Series ..............................................343.1 Setup Procedure for MC-0JFC11 or MC-0JFC21 Fibre Channel Cards .......... 34

3.1.1 Setting Up the Fibre Channel Card ........................................................................................... 343.1.2 Setting SAN Boot ....................................................................................................................... 363.1.3 Installing the VMware ESX Server ............................................................................................ 363.1.4 Setting Up the Fibre Channel Card Driver ................................................................................. 37

Appendix A WWN Instance Management Table for the Server (Blank) .....................................................................................39

Page 7: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 1 Workflow

P

This manual describes how to install and set up Fibre Channel cards when a PRIMERGY orPRIMEQUEST 1000 series is used.

Workflow

Set Up the Fibre Channel CardsInstall the Fibre Channel cards, acquire their physical addresses and WWN information, and perform the BIOS settings.

Refer

- For S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, and MC-FC82E Fibre Channel cards

� "2.1.1 Setting Up the Fibre Channel Card" (page 9)- For S26361-F3023-E1 Fibre Channel cards

� "2.2.1 Setting Up the Fibre Channel Card" (page 21)- For MC-0JFC11 or MC-0JFC21 Fibre Channel cards

� "3.1.1 Setting Up the Fibre Channel Card" (page 34)

Set Up SAN BootingSet up the SAN Boot configuration (if SAN Boot is to be used).

Refer

- For S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, and MC-FC82E Fibre Channel cards

� "2.1.2 Setting Up SAN Boot" (page 11)- For S26361-F3023-E1 Fibre Channel cards

� "2.2.2 Setting Up SAN Boot" (page 26)- For MC-0JFC11 or MC-0JFC21 Fibre Channel cards

� "3.1.2 Setting SAN Boot" (page 36)

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

7 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 8: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 1 Workflow >

P

After completing all the required procedures in this manual, proceed to "Check the LUNs"in "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) forVMware® ESX".

Install the VMware ESXInstall the VMware ESX software.

Refer

- For S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, and MC-FC82E Fibre Channel cards

� "2.1.3 Installing the VMware ESX Server" (page 17)- For S26361-F3023-E1 Fibre Channel cards

� "2.2.4 Installing the VMware ESX Server" (page 30)- For MC-0JFC11 or MC-0JFC21 Fibre Channel cards

� "3.1.3 Installing the VMware ESX Server" (page 36)

Set Up the Fibre Channel Card DriverSet up the parameters for the Fibre Channel card driver.

Refer

- For S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, and MC-FC82E Fibre Channel cards

� "2.1.4 Setting Up the Fibre Channel Card Driver" (page 17)- For S26361-F3023-E1 Fibre Channel cards

� "2.2.6 Setting Up the Fibre Channel Card Driver" (page 32)- For MC-0JFC11 or MC-0JFC21 Fibre Channel cards

� "3.1.4 Setting Up the Fibre Channel Card Driver" (page 37)

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

8 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 9: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY

P

2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

This section describes how to set up the VMware ESX server for use with the S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, or MC-FC82E Fibre Channel card.

When the S26361-F3023-E1 Fibre Channel card is used, follow the procedure in "2.2 SetupProcedure for S26361-F3023-E1 Fibre Channel Cards" (page 21).

2.1.1 Setting Up the Fibre Channel Card

Install the Fibre Channel card to the server and acquire its physical address and WWN (WorldWide Name).

� Physical address and Fibre Channel card WWN are required information in the cases shown as follows; when an error has occurred in the system, when using the ETERNUS Disk storage systems' host affinity function, etc., to restrict server access, or when connecting the ETERNUS Disk storage systems and the server using Fibre Channel switch.

� The relationship between a physical address and WWN cannot be determined from the BIOS. The physical address and WWN must be recorded as a pair when each Fibre Channel card is installed. Physical address and WWN must be assigned to "WWN instance management table for the server".

The procedures are described below:

(1) Install the Fibre Channel card

(2) Turn on the server

(3) Acquire the physical address and WWN for the Fibre Channel card

(4) Add a record for the server in the WWN instance management table for the server

Depending on the Fibre Channel card used, the actual on-screen FibreChannel card information may differ from that in the screenshots shown inthis document.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

9 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 10: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

The following describes the procedure:

Procedure

1 Install the Fibre Channel card to the server.For the installation method, slot positions and notes regarding the Fibre Channel card,refer to the manual provided with the Fibre Channel card or the User Guide of the server.

2 Turn on the server, and press the [Alt] + [E] keys while the following message is displayed.Light Pulse BIOS Utility starts.Example:

3 Enter the number of the Fibre Channel card to be checked and press the [Enter] key.Example:

4 Check the [I/O Base] and [Port Name] values.The value of [I/O Base] is the physical address and the value of [Port Name] is WWN.

Example:

!!! BX600-FC42E BIOS, Copyright(C) 2005 Emulex !!! Version xxxxxxPress <Alt E> to go to Emulex BIOS Utility.Press <s> to skip Emulex BIOS

Emulex Light Pulse BIOS Utility, ZBXXXXXXCopyright(C) 2005 Emulex Design & Manufacturing Corp

Emulex Adapters in the System;

1. BX600-FC42E PCI Bus #:xx PCI Device #:002. BX600-FC42E PCI Bus #:xx PCI Device #:00

Enter a Selection:Enter <x> to Exit <d> to Default Values <Esc> to Previous Menu

Adapter 0x: PCI Bus#:xx PCI Device#:00BX600-FC42E I/O Base: xxxx Firmware Version: ZS2.70A5Port Name: 1000 0000 xxxxxxxx Node Name: 2000 0000 xxxxxxxxTopology: Fabric Point to Point

1.Configure Boot Devices.2.Configure This Adapter’s Parameters.

Enter a Selection:

Enter <x> to Exit <d> to Default Values <Esc> to Previous Menu

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

10 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 11: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

5 Record the physical address and WWN in the "WWN instance management table for the server".This table is provided in "Appendix A WWN Instance Management Table for the Server(Blank)" (page 39).

The following shows an example of this.

Details of contents

6 Press the [X] key to quit the Light Pulse BIOS Utility.When the total number of ports for installed Fibre Channel cards is two or more, first turnthe server off, then repeat Step 1 through Step 6 above for each port, and record theinformation for all ports in the "WWN instance management table for the server".

End of procedure

2.1.2 Setting Up SAN Boot

The following describes the procedure when performing SAN Boot.

Host name: Record the host name.

IP Address: Record the IP address of the server.

Physical slot name: Record the slot position of installed Fibre Channel card.

Fibre Channel card WWN:

Record the value of [Port Name].

Instance name: Not necessary to record.

Physical address: Record the value of [I/O Base].

Cable tag: Record a tag name which indicates the connection path (relationship between the connected device and the port).

slot0 10 00 00 00 C9 38 D2 29 5000 SERV1_SLOT0 to SN200_1_port0

Server#1

192.168.0.10

Host name

IP Address

Physical slot name

Instancename

Physicaladdress

Cable tagFibre Channel cardWWN

Depending on the Fibre Channel card used, the actual on-screen FibreChannel card information may differ from that in the screenshots shown inthis document.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

11 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 12: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

Procedure

1 Turn on the server, and press the [Alt] + [E] keys while the following message is displayed.

2 Enter the number of the Fibre Channel card for which SAN Boot is to be set and press the [Enter] key.

3 Select "2. Configure This Adapter�s Parameters" and press the [Enter] key.

4 Select "1. Enable or Disable BIOS" and press the [Enter] key.

!!! BX600-FC42E BIOS, Copyright(C) 2005 Emulex !!! Version xxxxxxPress <Alt E> to go to Emulex BIOS Utility.Press <s> to skip Emulex BIOS

Emulex Light Pulse BIOS Utility, ZBXXXXXXCopyright(C) 2005 Emulex Design & Manufacturing Corp

Emulex Adapters in the System;

1. BX600-FC42E PCI Bus #:xx PCI Device #:002. BX600-FC42E PCI Bus #:xx PCI Device #:00

Enter a Selection:Enter <x> to Exit <d> to Default Values <Esc> to Previous Menu

Adapter 0x: PCI Bus #:xx PCI Device#:00 BX600-FC42E I/O Base:xxxx Firmware Version: ZS2.70A5 Port Name: 1000 0000 xxxxxxxx Node Name: 2000 0000 xxxxxxxx Topology: Fabric Point to Point

1. Configure Boot Devices.2. Configure This Adapter’s Parameters.

Enter a Selection: Enter <x> to Exit <d> to Default Values <Esc> to Previous Menu

Adapter 0x: PCI Bus #:xx PCI Device#:00 BX600-FC42E I/O Base:xxxx Firmware Version: ZS2.70A5 Port Name: 1000 0000 xxxxxxxx Node Name: 2000 0000 xxxxxxxx Topology: fabric Point to Point

1. Enable or Disable BIOS. 2. Change Default ALPA of this Adapter. 3. Change PLOGI Retry Timer (+Advanced Option+) 4. Topology Selection (+Advanced Option+) 5. Enable or Disable Spinup delay (+Advanced Option+) 6. Auto Scan Setting (+Advanced Option+) 7. Enable or Disable EDD 3.0 (+Advanced Option+) 8. Enable or Disable Start Unit Command (+Advanced Option+) 9. Enable or Disable Environment Variable (+Advanced Option+) A. Auto Sector Format Select (+Advanced Option+)

Enter a Selection:

Enter <x> to Exit <Esc> to Previous Menu

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

12 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 13: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

5 Input "1" and press the [Enter] key.

BIOS is now enabled."The BIOS is Disabled!" should have changed to "The BIOS is Enabled!".

6 Press the [ESC] key to return to the window shown in Step 4.

7 Select "4. Topology Selection" and press the [Enter] key.

8 Select either "1. Auto Topology: Loop first (Default)" (for FC-AL connection), or "4. Fabric Point to Point" (for fabric connection), and press the [Enter] key.

9 Press the [ESC] key to return to the window shown in Step 4.

10 Select "6. Auto Scan Setting" and press the [Enter] key.

Adapter 0x: PCI Bus #:xx PCI Device#:00

The BIOS is Disabled!

Enable Press 1, Disable Press 2:

Enter <x> to Exit <Esc> to Previous Menu

Adapter 0x: PCI Bus #:xx PCI Device#:00

The BIOS is Enabled!

Enable Press 1, Disable Press 2:

Enter <x> to Exit <Esc> to Previous Menu

Adapter 0X: PCI Bus #:xx PCI Device#:00

Topology: Fabric point to Point

1. Auto Topology: Loop first (Default) 2. Auto Topology: Pt to Pt first 3. FC-AL 4. Fabric Point to Point

Enter a Selection:

Enter <x> to Exit <Esc> to Previous Menu

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

13 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 14: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

11 Displays the changed Auto scan setting of the boot device. Input the number (1 to 4) of the desired Auto scan setting after "Enter a Selection:" and press the [Enter] key.

12 Press the [X] key to quit the Light Pulse BIOS Utility.

13 Input "Y" after "REBOOT THE SYSTEM(Y/N):" to boot the server to reflect the new setting.

14 Press the [Alt] + [E] keys while the startup message is displayed.

15 Input the number of the Fibre Channel card selected in Step 2 after "Enter a Selection:" and press the [Enter] key.

Adapter 0X: PCI Bus #:xx PCI Device#:00

Auto scan setting: First LUN 0 device.

1. Auto scan disabled (Default) 2. Any first device. 3. First LUN 0 device. 4. First NOT LUN 0 device.

Enter a Selection:

Enter <x> to Exit <Esc> to Previous Menu

Reboot the System to Make All the Changes to Take Effect!

REBOOT THE SYSTEM(Y/N):_

!!! Emulex LPxxxx BIOS Copyright 1998 !!! xxxxxxxxPress <Alt E> to go to Emulex BIOS Utility.Press <s> to skip Emulex BIOS.

!!!BX600-FC42E BIOS, Copyright(c) 2005 Emulex !!! Version xxxxxxPress <Alt E> to go to Emulex BIOS UtilityPress <s> to skip Emulex BIOS

Emulex Light Pulse BIOS Utility, ZBxxxxxx Copyright(c) 2005 Emulex Design & Manufacturing Corp

Emulex Adapters in the System;

1. BX600-FC42E PCI Bus #:xx PCI Device #:002. BX600-FC42E PCI Bus #:xx PCI Device #:00

Enter a Selection:

Enter <x> to Exit <d> to Default Values <Esc> to Previous Menu

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

14 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 15: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

16 Select "1. Configure Boot Devices" and press the [Enter] key.

17 Select a boot device. Input "1" after "Select a Boot Entry:" and press the [Enter] key.

18 A list of the WWPNs and recognized LUNs (as device names) of the connected ETERNUS8000 is displayed. Input the number of the device that is to be used for SAN Booting and press the [Enter] key. Select "01" in this example.

From Step 17 onward, the examples assume the use of LUN00 andthe device name "ETERNUS8000" for the Primary Boot device.

Adapter 0x: PCI Bus #:xx PCI Device#:00 BX600-FC42E I/O Base:xxxx Firmware Version: ZS2.70A5 Port Name: 1000 0000 xxxxxxxx Node Name: 2000 0000 xxxxxxxx Topology: Fabric point to Point

1. Configure Boot Devices.2. Configure This Adapter’s Parameters.

Enter a Selection:

Enter <x> to Exit <d> to Default Values <Esc> to Previous Menu

Adapter 0x: S_ID: xxxxxx PCI Bus #:xx PCI Device#:00

List of Saved Boot Devices:

1. Unused DID:000000 WWPN:00000000 00000000 LUN:00 Primary Boot 2. Unused DID:000000 WWPN:00000000 00000000 LUN:00 3. Unused DID:000000 WWPN:00000000 00000000 LUN:00 4. Unused DID:000000 WWPN:00000000 00000000 LUN:00 5. Unused DID:000000 WWPN:00000000 00000000 LUN:00 6. Unused DID:000000 WWPN:00000000 00000000 LUN:00 7. Unused DID:000000 WWPN:00000000 00000000 LUN:00 8. Unused DID:000000 WWPN:00000000 00000000 LUN:00

Select a Boot Entry:

Enter <x> to Exit <Esc> to Previous Menu

Adapter 0x: S_ID :xxxxxx PCI Bus #:xx PCI Device#:00

00. Clear Selected Boot Entry!! 01. DID:xxxxxx WWPN:2041000B 5D6A0336 LUN:00 FUJITSU E8000 0000 02. DID:xxxxxx WWPN:2043000B 5D6A0336 LUN:0x FUJITSU E8000 0000

Select the Two Digit Number of The Desired Boot Device:01

Enter <x> to Exit <Esc> to Previous Menu <PageDn> to Next Page

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

15 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 16: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

19 Input the starting LUN as a two-digit hexadecimal number and press the [Enter] key. Input "00" in this example.

20 Select a boot device startup method (via WWPN or via DID). From the list of LUNs recognized by the device select the LUN number whose setting is to be changed, input the number after "Enter a Selection:" and press the [Enter] key.LUN: 00 is used for SAN Booting, so input "01" and press the [Enter] key in this example.

21 In the sub-menu that is displayed in the center of the window decide whether the boot is to be via WWPN or via DID for the selected LUN, input the number of the selected method after "Enter a Selection:" and press the [Enter] key.Input "1" for WWPN in this example.

Adapter 0x: S_ID :xxxxxx PCI Bus #:xx PCI Device#:00

00. Clear Selected Boot Entry!! 01. DID:xxxxxx WWPN:2041000B 5D6A0336 LUN:00 FUJITSU E8000 0000 02. DID:xxxxxx WWPN:2043000B 5D6A0336 LUN:0x FUJITSU E8000 0000

Select the Two Digit Number of The Desired Boot Device:

Enter <x> to Exit <Esc> to Previous Menu <PageDn> to Next Page

DID: xxxxxx WWPN: xxxxxxxx xxxxxxxx Enter two digits of starting LUN(Hex):00 <Esc> to Previous Menu

Adapter 0x: S_ID: xxxxxx PCI Bus #:xx PCI Device#:00

DID: xxxxxx WWPN:xxxxxxxx xxxxxxxx

01. LUN:00 FUJITSU E8000 0000 02. LUN:01 FUJITSU E8000 0000

Enter a Selection:01 B#W: Boot number via WWPN. B#D: Boot number via DID Enter <x> to Exit <Esc> to Previous Menu <PageDn> to Next Page

Adapter 0x: S_ID: xxxxxx PCI Bus #:xx PCI Device#:00

DID: xxxxxx WWPN:xxxxxxxx xxxxxxxx

01. LUN:00 FUJITSU E8000 000002. LUN:00 FUJITSU E8000 0000

Enter a Selection:B#W: Boot number via WWPN, B#D: Boot number via DID

Enter <x> to Exit <Esc> to Previous Menu <PageDn> to Next Page

DID: xxxxxx WWPN: xxxxxxxx xxxxxxxx LUN: 0x 1.Boot this device via WWPN 2.Boot this device via DID <Esc> to Precious Menu Enter a Selection:1

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

16 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 17: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

22 The window shown in Step 17 reappears. Check the settings.In this example, check that item #1 is listed as "Used", that the "WWPN" is set to the actualETERNUS8000 WWPN, and that the "LUN" is set to "00" and that it bears the "PrimaryBoot" label.

23 Press the [Esc] key twice to return to the window shown in Step 2.If multiple Fibre Channel cards are to be installed, repeat Step 2 through Step 23 for eachcard.

24 Press the [X] key to quit the Light Pulse BIOS Utility.

End of procedure

2.1.3 Installing the VMware ESX Server

VMware ESX should be installed now if it has not yet been installed on the server. Refer to thefollowing URL for details.

http://www.vmware.com/support/pubs/

2.1.4 Setting Up the Fibre Channel Card Driver

To connect to the ETERNUS2000, change the parameters for the Fibre Channel card driver.

Adapter 0x: S_ID: xxxxxx PCI Bus #:xx PCI Device#:00

List of Saved Boot Devices:

1. Used DID:000000 WWPN:xxxx xxxx xxxx xxxx LUN:00 Primary Boot 2. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00 3. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00 4. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00 5. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00 6. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00 7. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00 8. Unused DID:000000 WWPN:0000 0000 0000 0000 LUN:00

Select a Boot Entry:

Enter <x> to Exit <Esc> to Previous Menu

When connecting to the ETERNUS4000 or ETERNUS8000, theparameters for the Fibre Channel card driver do not have to be changedbecause the default values of the standard driver for VMware ESX areused.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

17 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 18: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

2.1.4.1 For VMware vSphere

Procedure

F

1 Record the module name for the Fibre Channel card that is loaded into VMware ESX.In the following example, "lpfc820" is recorded as the module name.

Module names may vary depending on the Fibre Channel card that is used.

2 Check the default value for the Fibre Channel card.Specify the module name for the Fibre Channel card that you recorded in Step 1 andcheck the default value.

3 Check the number of ports on the Fibre Channel card.The SCSI Host numbers of the Fibre Channel card that are displayed represent thenumber of ports.In the following example, the number of ports is "two" since "4" and "5" (two numbers) aredisplayed as the SCSI Host numbers of the Fibre Channel card.

4 Change the setting values of the parameter for the Fibre Channel card driver.

Use the following command to change the setting values when the driver parameter nameis "lpfcX_lun_queue_depth", the number of I/Os is "8", the module name is "lpfc820", andthe number of ports is "2".

Driver parameterDriver parameter setting values

Number of I/Os when 16 or less LUNs are used

Number of I/Os when 17 or more LUNs are used

lpfcX_lun_queue_depth 8 4

# vmkload_mod -l | grep lpfc*lpfc820 ↑ Loaded module name

# esxcfg-module -g lpfc820lpfc820 enabled = 1 options = '' ← Check that no value appears.

# ls /proc/scsi/lpfc4 5

↑ ↑The number of ports is "two".

# esxcfg-module -s "lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8" lpfc820

Input the number of I/Os ("8" in this example) for each driver parameter setting.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

18 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 19: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

5 Check the setting values.

6 Reboot VMware ESX.

End of procedure

2.1.4.2 For VMware Infrastructure 3

Procedure

1 Record the module name for the Fibre Channel card that is loaded into VMware ESX.In the following example, "lpfc_740" is recorded as the module name.

Module names may vary depending on the Fibre Channel card that is used.

2 Check the default value for the Fibre Channel card.Specify the module name for the Fibre Channel card that you recorded in Step 1 andcheck the default value.

3 Check the number of ports on the Fibre Channel card.The SCSI Host numbers of the Fibre Channel card that are displayed represent thenumber of ports.In the following example, the number of ports is "two" since "4" and "5" (two numbers) aredisplayed as the SCSI Host numbers of the Fibre Channel card.

# esxcfg-module -g lpfc820lpfc820 enabled = 1 options = 'lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8'

# reboot

# vmkload_mod -l | grep lpfc*lpfc_740 ↑ Loaded module name

# esxcfg-module -g lpfc_740lpfc_740 enabled = 1 options = '' ← Check that no value appears.

# ls /proc/scsi/lpfc4 5

↑ ↑The number of ports is "two".

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

19 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 20: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards

P

4 Change the setting values of the parameter for the Fibre Channel card driver.

Use the following command to change the setting values when the driver parameter nameis "lpfcX_lun_queue_depth", the number of I/Os is "8", the module name is "lpfc_740", andthe number of ports is "2".

5 Check the setting values.

6 Update the loaded module.

7 Reboot VMware ESX.

End of procedure

Driver parameterDriver parameter setting values

Number of I/Os when 16 or less LUNs are used

Number of I/Os when 17 or more LUNs are used

lpfcX_lun_queue_depth 8 4

# esxcfg-module -s "lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8" lpfc_740

Input the number of I/Os ("8" in this example) for each driver parameter setting.

# esxcfg-module -g lpfc_740lpfc_740 enabled = 1 options = 'lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8'

# esxcfg-boot -b

# reboot

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

20 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 21: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

This section describes how to set up the VMware ESX server for use with the S26361-F3023-E1Fibre Channel card.

When the S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/S26361-F3141-E210,S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, or MC-FC82E FibreChannel card is used, follow the procedure in "2.1 Setup Procedure for non-S26361-F3023-E1Fibre Channel Cards" (page 9).

2.2.1 Setting Up the Fibre Channel Card

Install the Fibre Channel card to the server and acquire its physical address and WWN (WorldWide Name).

� Physical address and Fibre Channel card WWN are required information in the cases shown as follows; when an error has occurred in the system, when using the ETERNUS Disk storage systems' host affinity function, etc., to restrict server access, or when connecting the ETERNUS Disk storage systems and the server using Fibre Channel switch.

� The relationship between a physical address and WWN cannot be determined from the BIOS. The physical address and WWN must be recorded as a pair when each Fibre Channel card is installed. Physical address and WWN must be assigned to "WWN instance management table for the server".

The procedures are described below:

(1) Install the Fibre Channel card

(2) Turn on the server

(3) Acquire the physical address and WWN for the Fibre Channel card

(4) Add a record for the server in the WWN instance management table for the server

Depending on the Fibre Channel card used, the actual on-screen FibreChannel card information may differ from that in the screenshots shown inthis document.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

21 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 22: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

The following describes the procedure:

Procedure

1 Install the Fibre Channel card to the server.For the installation method, position (PCI bus slots), and notes regarding the FibreChannel card, refer to the manual provided with the Fibre Channel card or the User Guideof the server.

2 Turn on the server, and press the [Ctrl] + [Q] keys while the following message is displayed."Fast!UTIL" program starts up (Startup may take longer than usual).

� When the "Fast!UTIL" program is started in a single-Fibre-Channel-card-installed environment, the following window appears.

� When the "Fast!UTIL" program is started in a multiple-Fibre-Channel-cards-installed environment, the [Select Host Adapter] window appears. Select the second Fibre Channel card, and press the [Enter] key to get the above window.

When two 2-port Fibre Channel cards are installed (for a total of four ports), fourchoices are displayed on this screen.

QLogic CorporationQLA23xx PCI Fibre Channel ROM BIOS Version *.**Copyright(C) QLogic Corporation 2000. All rights reservedwww.qlogic.com

Press <CTRL-Q> for Fast!UTIL

Adapter Type

QLA2xxx

I/O Address

3400

Select Host Adapter

Configuration SettingsScan Fibre DevicesFibre Disk UtilitySelect Host AdapterExit Fast!UTIL

Fast!UTIL Options

Adapter Type I/O Address

QLA2xxxQLA2xxx

34003800

Select Host Adapter

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

22 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 23: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

3 Check the value of [I/O Address].The value of [I/O Address] is the physical address.

4 Select [Configuration Settings] from [Fast!UTIL Options] menu.

5 Select [Host Adapter Settings] and press the [Enter] key.

Check the value of [Adapter Port Name].The value of [Adapter Port Name] is the Fibre Channel card WWN.

6 Record the physical address and WWN in the "WWN instance management table for the server".This table is provided in "Appendix A WWN Instance Management Table for the Server(Blank)" (page 39).

The following shows an example of this.

Adapter Type

QLA2xxx

I/O Address

3400

Select Host Adapter

Physicaladdress

Advanced Adapter Settings

Selectable Boot SettingsRestore Default SettingsRaw Nvram Data

Host Adapter Settings

Extended Firmware Settings

Configuration Settings

Host Adapter Settings

BIOS AddressBIOS RevisionAdapter Serial NumberInterrupt LevelAdapter Port NameHost Adapter BIOS

:xxxxx:x.xx:xxxxxx:xx:200000E08B0214D0:Disabled

slot0 20 00 00 E0 8B 02 14 D0 3400 SERV1_SLOT0 to SN200_1_port0

Server#1

192.168.0.10

Host name

IP Address

Physical slot name

Fibre Channel cardWWN

Instancename

Physicaladdress

Cable tag

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

23 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 24: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

Details of contents

7 Check the values for each parameter in the [Host Adapter Settings] window.Refer to the section for the installed Fibre Channel card in "2.2.5 Setting Up the FibreChannel Card BIOS" (page 30) and set each value.For details on how to set the values, refer to Fibre Channel card user guide.

8 Return to the [Configuration Settings] menu by pressing the [Esc] key.

9 Select [Advanced Adapter Settings] and press the [Enter] key.

10 Check the values for each parameter in the [Advanced Adapter Settings] window.Refer to the section for the installed Fibre Channel card in "2.2.5 Setting Up the FibreChannel Card BIOS" (page 30) and set each value.

Host name: Record the host name.

IP Address: Record the IP address of the server.

Physical slot name: Record the slot position of installed Fibre Channel card.

Fibre Channel card WWN:

Record the value of [Adapter Port Name].

Instance name: Not necessary to record.

Physical address: Record the value of [I/O Address].

Cable tag: Record a tag name which indicates the connection path (relationship between the connected device and the port).

Advanced Adapter Settings

Selectable Boot SettingsRestore Default SettingsRaw Nvram Data

Host Adapter Settings

Extended Firmware Settings

Configuration Settings

Execution ThrottleLUNs per TargetEnable LIP ResetEnable LIP Full LoginEnable Target ResetLogin Retry CountPort Down Retry CountLink Down TimeoutExtended Error LoggingRIO Operation ModeInterrupt Delay Timer

:xx:8:No:Yes:Yes:8:30:30:Disabled:0:0

Advanced Adapter Settings

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

24 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 25: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

11 Press the [Esc] key twice to return to the [Fast!UTIL Options] menu.If the BIOS settings were changed, save the settings using [Save xxxxxx].When two or more Fibre Channel cards are installed in the server, select the second orlater Fibre Channel card using the following Steps, and set the BIOS of selected card.

11-1 Select [Select Host Adapter] and press the [Enter] key.

11-2 Select the Fibre Channel card to be set (BIOS setting) in the [Select Host Adapter] window. The [Fast!UTIL Options] menu appears. Then perform Step 2 through Step 11 shown here.

12 Select [Exit Fast!UTIL] and press the [Enter] key.

13 Select [Reboot System] and press the [Enter] key.Server reboots.To return to the [Fast!UTIL] menu, select [Return to Fast!UTIL].

End of procedure

Fast!UTIL Options

Configuration SettingsScan Fibre DevicesFibre Disk UtilitySelect Host AdapterExit Fast!UTIL

Fast!UTIL Options

Adapter Type I/O Address

QLA2xxxQLA2xxx

34003800

Select Host Adapter

Reboot SystemReturn to Fast!UTIL

Exit Fast!UTIL

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

25 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 26: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

2.2.2 Setting Up SAN Boot

The following describes the procedure when performing SAN Boot.

Procedure

1 Turn on the server, and press the [Ctrl] + [Q] keys while the following message is displayed."Fast!UTIL" program starts up (Startup may take longer than usual).

2 Select [Configuration Settings] and press the [Enter] key.

3 Select [Host Adapter Settings] and press the [Enter] key.

Depending on the Fibre Channel card used, the actual on-screen FibreChannel card information may differ from that in the screenshots shown inthis document.

QLogic CorporationQLA23xx PCI Fibre Channel ROM BIOS Version *.**Copyright(C) QLogic Corporation 2000. All rights reservedwww.qlogic.com

Press <CTRL-Q> for Fast!UTIL

Advanced Adapter Settings

Selectable Boot SettingsRestore Default SettingsRaw Nvram Data

Host Adapter Settings

Extended Firmware Settings

Configuration Settings

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

26 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 27: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

4 Check the value of [Host Adapter BIOS].Set the [Host Adapter BIOS] to "Enabled".For details of the setting procedure, refer to the Fibre Channel card user's guide.When setting parameter other than the [Host Adapter BIOS], refer to "2.2.5 Setting Up theFibre Channel Card BIOS" (page 30).

5 Return to the [Configuration Settings] menu by pressing the [Esc] key.

6 Press the [Esc] key twice to return to the [Fast!UTIL Options] menu.If the BIOS settings were changed, save the settings using [Save xxxxxx].When two or more Fibre Channel cards are installed in the server, select the second orlater Fibre Channel card using the following Steps, and set the BIOS of selected card.

7 Select [Select Host Adapter] from the [Fast!UTIL Options] menu and press the [Enter] key.

7-1 Select the Fibre Channel card to be set (BIOS setting).

7-2 The [Fast!UTIL Options] menu appears. Then perform Step 2 through Step 6 shown here.

8 Select [Exit Fast!UTIL] and press the [Enter] key.

BIOS AddressBIOS RevisionAdapter Serial NumberInterrupt LevelAdapter Port NameHost Adapter BIOSFrame SizeLoop Reset DelayAdapter Hard Loop IDHard Loop IDSpinup DelayConnection OptionsFibre Channel Tape SupportData Rate

:xxxxx:x.xx:xxxxxx:xx:200000E08B0214D0:Disabled:2048:5:Disabled:0:Disabled:2:Enabled:2

Host Adapter Settings

Fast!UTIL Options

Configuration SettingsScan Fibre DevicesFibre Disk UtilitySelect Host AdapterExit Fast!UTIL

Fast!UTIL Options

Adapter Type I/O Address

QLA2xxxQLA2xxx

34003800

Select Host Adapter

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

27 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 28: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

9 Select [Reboot System] and press the [Enter] key.Server reboots.To return to the [Fast!UTIL] menu, select [Return to Fast!UTIL].

End of procedure

2.2.3 Setting the Selectable Boot

Procedure

1 Select [Selectable Boot Settings] from the [Configuration Settings] menu and press the [Enter] key.

2 Set [Selectable Boot] to "Enabled".

3 Set a boot path (ETERNUS Disk storage system port WWN) and boot LUN#.

4 Check the values for each parameter.

Reboot SystemReturn to Fast!UTIL

Exit Fast!UTIL

The boot path and boot LUN# selection window only appears when[Host Adapter BIOS] is "Enabled" in [SAN Boot].If [Host Adapter BIOS] is "Disabled", the boot path and boot LUN#selection window does not appear. Instead, the window shown inStep 4 appears when [Selectable Boot Settings] is selected.

Selectable BootBoot Port Name, Lun

:Disabled:0000000000000000,0

Selectable Boot Settings

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

28 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 29: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

5 Return to the [Configuration Settings] menu by pressing the [Esc] key.

6 Press the [Esc] key twice to return to the [Fast!UTIL Options] menu.If the BIOS settings were changed, save the settings using [Save xxxxxx].When two or more Fibre Channel cards are installed in the server, select the second orlater Fibre Channel card using the following Steps, and set the BIOS of selected card.

6-1 Select [Select Host Adapter] from the [Fast!UTIL Options] menu and press the [Enter] key.

6-2 Select the Fibre Channel card to be set (BIOS setting).

6-3 The [Fast!UTIL Options] menu appears. Then perform Step 1 through Step 6 shown here.

7 Select [Exit Fast!UTIL] and press the [Enter] key.

Parameter Value Remarks

Selectable Boot Enabled or Disabled

� The factory default value is [Disabled].� [Enabled] for SAN Boot.� [Disabled] for non SAN Boot.

Boot Port Name, Lun

ETERNUS Disk storage system port WWN, LUN#or 0000000000000000, 0

� The factory default value is "0000000000000000, 0".

� "Boot path (ETERNUS Disk storage system port WWN), boot LUN#" for SAN Boot.

� "0000000000000000, 0" for non SAN Boot.

Fast!UTIL Options

Configuration SettingsScan Fibre DevicesFibre Disk UtilitySelect Host AdapterExit Fast!UTIL

Fast!UTIL Options

Adapter Type I/O Address

QLA2xxxQLA2xxx

34003800

Select Host Adapter

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

29 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 30: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

8 Select [Reboot System] and press the [Enter] key.

Server reboots.To return to the [Fast!UTIL] menu, select [Return to Fast!UTIL].

End of procedure

2.2.4 Installing the VMware ESX Server

If the VMware ESX software is not installed in the server, contact your sales representative.

2.2.5 Setting Up the Fibre Channel Card BIOS

When S26361-F3023-E1 Fibre Channel cards are used, set following parameters to the indi-cated values.If the current parameter values are different, change them to the indicated values.

All other parameters should be left on their default values.� [Host Adapter Settings] window

Reboot SystemReturn to Fast!UTIL

Exit Fast!UTIL

Parameter Value Default Remarks

BIOS Address

Fixed for each card � Settings cannot be changed.

BIOS Revision (*1)

Adapter Serial Number

Interrupt Level

Adapter Port Name

Host Adapter BIOS Enabled or Disabled Disabled

� Set [Enabled] for SAN Boot.� Set [Disabled] for non SAN Boot.

Frame Size 2048 2048

Loop Reset Delay 5 5

Adapter Hard Loop ID Disabled Disabled

Hard Loop ID 0 0

Spinup Delay Disabled Disabled

Connection Options 0 (FC-AL)1 (fabric) 2

� Set "0" for FC-AL connection.� Set "1" for fabric connection.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

30 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 31: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

*1: BIOS version of the Fibre Channel card is displayed. Check that the BIOS version is the same asshown in "Server Support Matrix".

� [Advanced Adapter Settings] windowSet following parameters to the indicated values.If the current parameter values are different, change them to the indicated values.

Fibre Channel Tape Support Disabled Enabled Change the setting from "Enabled" to

"Disabled".

Data Rate 0 (1Gb/s)1 (2Gb/s)

2 (Auto Select)

� For fabric connection- Set "0" for a 1Gbps Fibre

Channel switch- Set "1" for an 8Gbps, 4Gbps,

or 2Gbps Fibre Channel switch

� For FC-AL connection- Set "0" for a 1Gbps CA

(maximum speed)- Set "1" for a 4Gbps or 2Gbps

CA (maximum speed)

Parameter Value Default Value Remarks

Execution Throttle 16 16

LUNs per Target 8 8

Enable LIP Reset No No

Enable LIP Full Login Yes Yes

Enable Target Reset Yes Yes

Login Retry Count 8 8

Port Down Retry Count 30 30

Link Down Timeout 30 30

Extended Error Logging Disabled Disabled

RIO Operation Mode 0 0

Interrupt Delay Timer 0 0

Parameter Value Default Remarks

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

31 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 32: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

2.2.6 Setting Up the Fibre Channel Card Driver

To connect to the ETERNUS2000, change the parameters for the Fibre Channel card driver.

Procedure

1 Record the module name for the Fibre Channel card that is loaded into VMware ESX.In the following example, "qla2300_707_vmw" is recorded as the module name.

2 Check the default value for the Fibre Channel card.Specify the module name for the Fibre Channel card that you recorded in Step 1 andcheck the default value.

3 Change the setting value for the number of I/Os on the Fibre Channel card.

Use the following command to change the setting values when the driver parameter nameis "q l2xmaxqdepth" , the number o f I /Os i s "8 " , and the modu le name is"qla2300_707_vmw".

When connecting to the ETERNUS4000 or ETERNUS8000, theparameters for the Fibre Channel card driver do not have to be changedbecause the default values of the standard driver for VMware ESX areused.

Module names may vary depending on the Fibre Channel card thatis used.

Driver parameterDriver parameter setting values

Number of I/Os when 16 or less LUNs are used

Number of I/Os when 17 or more LUNs are used

ql2xmaxqdepth 8 4

# vmkload_mod -l | grep qla2300qla2300_707_vmw ↑ Loaded module name

# esxcfg-module -g qla2300_707_vmwqla2300_707_vmw enabled = 1 options = '' ← Check that no value appears.

# esxcfg-module -s ql2xmaxqdepth=8 qla2300_707_vmw

Input the number of I/Os ("8" in this example) for driver parameter setting.

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

32 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 33: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 2 For PRIMERGY > 2.2 Setup Procedure for S26361-F3023-E1 Fibre Channel Cards

P

4 Check the setting values.

5 Update the loaded module.

6 Reboot VMware ESX.

End of procedure

This option cannot be individually applied to each port on the FibreChannel card.All ports on the target Fibre Channel card are configured with thesame settings.

# esxcfg-module -g qla2300_707_vmwqla2300_707_vmw enabled = 1 options = 'l ql2xmaxqdepth =8'

# esxcfg-boot -b

# reboot

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

33 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 34: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 3 For PRIMEQUEST 1000 Series

P

3.1 Setup Procedure for MC-0JFC11 or MC-0JFC21 Fibre Channel Cards

This section describes how to set up the VMware ESX server for use with the MC-0JFC11 orMC-0JFC21 Fibre Channel cards.

3.1.1 Setting Up the Fibre Channel Card

Install the Fibre Channel card to the server and acquire its physical address and WWN (WorldWide Name).

� Physical address and Fibre Channel card WWN are required information in the cases shown as follows; when an error has occurred in the system, when using the ETERNUS Disk storage systems' host affinity function, etc., to restrict server access, or when connecting the ETERNUS Disk storage systems and the server using Fibre Channel switch.

� The relationship between a physical address and WWN cannot be determined from the BIOS. The physical address and WWN must be recorded as a pair when each Fibre Channel card is installed. Physical address and WWN must be assigned to "WWN instance management table for the server".

The procedures are described below:

(1) Install the Fibre Channel card

(2) Turn on the server

(3) Acquire the physical address and WWN for the Fibre Channel card

(4) Add a record for the server in the WWN instance management table for the server

Add the acquired record in the "WWN instance management table for the server" (found in"Appendix A WWN Instance Management Table for the Server (Blank)" (page 39)).

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

34 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 35: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 3 For PRIMEQUEST 1000 Series > 3.1 Setup Procedure for MC-0JFC11 or MC-0JFC21 Fibre Channel Cards

P

The following describes the procedure:

Procedure

1 Install the Fibre Channel card to the server.For the installation method, slot positions and notes regarding the Fibre Channel card,refer to the manual provided with the Fibre Channel card or the User Guide of the server.

2 Use the UEFI Shell to enter the following command to output a list of the drivers.

3 Specify the identification number of the target driver.

4 Enter the number of the Fibre Channel card to be checked and press the [Enter] key.Select the HBA to set or check from the output HBA list.

5 Display the HBA setup utility.Select [1. Setup Utility] from the displayed menu.

6 Check the [I/O Base] and [Port Name] values.Check the [I/O Base] and [Port Name] values from the displayed menu.The value of [I/O Base] is the physical address and the value of [Port Name] is WWN.

Example:

shell > drivers

shell > drvcfg -s Driver_identification_number

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

35 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 36: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 3 For PRIMEQUEST 1000 Series > 3.1 Setup Procedure for MC-0JFC11 or MC-0JFC21 Fibre Channel Cards

P

7 Record the physical address and WWN in the "WWN instance management table for the server".This table is provided in "Appendix A WWN Instance Management Table for the Server(Blank)" (page 39).

The following shows an example of this.

Details of contents

8 Press the [ESC] key to quit [Setup Utility].When the total number of ports for installed Fibre Channel cards is two or more, repeatStep 1 through Step 6 above for each port, and record the information for all ports in the"WWN instance management table for the server".

End of procedure

3.1.2 Setting SAN Boot

If a SAN Boot environment is to be set up, the SAN Boot settings must be made beforehand forthe PRIMEQUEST 1000 series. Refer to "Appendix D Configuration in the SAN Boot Environ-ment" in "PRIMEQUEST 1000 series INSTALLATION MANUAL" for details.

3.1.3 Installing the VMware ESX Server

VMware ESX should be installed now if it has not yet been installed on the server. Refer to thefollowing URL for details.

http://www.vmware.com/support/pubs/

Host name: Record the host name.

IP Address: Record the IP address of the server.

Physical slot name: Record the slot position of installed Fibre Channel card.

Fibre Channel card WWN:

Record the value of [Port Name].

Instance name: Not necessary to record.

Physical address: Record the value of [I/O Base].

Cable tag: Record a tag name which indicates the connection path (relationship between the connected device and the port).

slot0 10 00 00 00 C9 38 D2 29 5000 SERV1_SLOT0 to SN200_1_port0

Server#1

192.168.0.10

Host name

IP Address

Physical slot name

Instancename

Physicaladdress

Cable tagFibre Channel cardWWN

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

36 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 37: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 3 For PRIMEQUEST 1000 Series > 3.1 Setup Procedure for MC-0JFC11 or MC-0JFC21 Fibre Channel Cards

P

3.1.4 Setting Up the Fibre Channel Card Driver

To connect to the ETERNUS2000, change the parameters for the Fibre Channel card driver.

Procedure

1 Record the module name for the Fibre Channel card that is loaded into VMware ESX.In the following example, "lpfc820" is recorded as the module name.

Module names may vary depending on the Fibre Channel card that is used.

2 Check the default value for the Fibre Channel card.Specify the module name for the Fibre Channel card that you recorded in Step 1 andcheck the default value.

3 Check the number of ports on the Fibre Channel card.The SCSI Host numbers of the Fibre Channel card that are displayed represent thenumber of ports.In the following example, the number of ports is "two" since "4" and "5" (two numbers) aredisplayed as the SCSI Host numbers of the Fibre Channel card.

When connecting to the ETERNUS4000 or ETERNUS8000, theparameters for the Fibre Channel card driver do not have to be changedbecause the default values of the standard driver for VMware ESX areused.

# vmkload_mod -l | grep lpfc*lpfc820 ↑ Loaded module name

# esxcfg-module -g lpfc820lpfc820 enabled = 1 options = '' ← Check that no value appears.

# ls /proc/scsi/lpfc4 5

↑ ↑The number of ports is "two".

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

37 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 38: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Chapter 3 For PRIMEQUEST 1000 Series > 3.1 Setup Procedure for MC-0JFC11 or MC-0JFC21 Fibre Channel Cards

P

4 Change the setting values of the parameter for the Fibre Channel card driver.

Use the following command to change the setting values when the driver parameter nameis "lpfcX_lun_queue_depth", the number of I/Os is "8", the module name is "lpfc820", andthe number of ports is "2".

5 Check the setting values.

6 Reboot VMware ESX.

End of procedure

Driver parameterDriver parameter setting values

Number of I/Os when 16 or less LUNs are used

Number of I/Os when 17 or more LUNs are used

lpfcX_lun_queue_depth 8 4

# esxcfg-module -s "lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8" lpfc820

Input the number of I/Os ("8" in this example) for each driver parameter setting.

# esxcfg-module -g lpfc820lpfc820 enabled = 1 options = 'lpfc0_lun_queue_depth=8 lpfc1_lun_queue_depth=8'

# reboot

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

38 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 39: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

Appendix A WWN Instance Management Table for the Server (Blank)

P

This table is used when checking the Fibre Channel cards, and should be used as necessary.

Host name

IP Address

Physical slot name

Fibre Channel cardWWN

Instancename

Physicaladdress

Cable tag

WWN instance management table for the server

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware® ESX

39 Copyright 2010 FUJITSU LIMITED

3AM-2862-06ENZ0

Page 40: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure

� The contents of this manual are liable to being updated without notice.� While the contents of this manual are the product of all due care and diligence, no

responsibility can be accepted for operational problems arising from any errors or missing information, or other use of the information contained in this manual.

� Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

� Contents of this manual are not to be reproduced without permission from Fujitsu.

ETERNUS Disk storage systemsServer Connection Guide (Fibre Channel) for VMware® ESXDriver Settings for PRIMERGY/PRIMEQUEST 1000 Series

P3AM-2862-06ENZ0

Date of issuance: December 2010Issuance responsibility: FUJITSU LIMITED

Page 41: ETERNUS Disk storage systems Server Connection …...Channel card information may differ from that in the screenshots shown in this document. Chapter 2 For PRIMERGY > 2.1 Setup Procedure