116
F FUME HOOD
ModelFH10
DFH10 (Ductless)
FH12
DFH12 (Ductless)
FH15
DFH15 (Ductless)
External size (mm) 1000x750x2200 1200x750x2200 1500x750x2200
Internal size (mm) 900x570x745 1100x570x745 1320x745x800
Application Provide protection to the operator
MaterialWork surface: solid chemical-resistant laminate
Exterior: expoxy coated cold-rolled steel
Relative humidity 75%
Ambient temperature 15C~35C
Control Microprocessor control with touch buttons
Front sash Sliding tempered glass, thickness no less than 5mm
Duct length 4m
Duct collar size 10 inch
Inflow velocity Average 0.5m/s
Vibration 5m (rms) between the frequency of 10Hz and 10K Hz
Noise level 60db
Lightning 680lux
Fan Centrifugal, adjustable speed
Power 800W
Power supply 220V, 50Hz
Option Water tap, gas tap, cup sink, etc.
Compliance CE
It is the new technical instrument in
air condition workshop and clean
workshop. And it is widely
applicable in electronics,
mechanics, medical, anduniversity labs.
Fume hood can be used in
operation of potential risk or
unknown infected factors,
and the experiment of
flammability, explosive
volatilization and narcotics.
It can protect operator and
samples.
FH/DFH Series, Fume Hood
FH/DFH
With StandFH/DFH
7/29/2019 Especificaciones Tecnicas Fume Hood
2/7
117
FFUME HOOD
Model BSC11A
Overall dimension (mm) 680x400x1160
Operation are dimension (mm) 630x375x615
Filter dimension 305x610x69
Filter efficiency For 0.3m particulates, filter efficiency>99.99%
BSC11A, Class I
BYKG-I-II & BYKG-III-IV-V Class IThe Class I Biological Safety Cabinet is a negative-pressure, ventilated
cabinet usually operated with an open front and a minimum face velocity
at the work opening of at least 75 linear feet per minute (lfpm). All of the
air from the cabinet is sent through a HEPA filter, either into the
laboratory or to the outside.
Operating Range
Running conditions 220V~240V / 50Hz ~ 60Hz
Operating temperature range: 15-35C
Operating humidity range 85%
Parameter and Function
Configuration for BYKG-I-II: constituted of light-permeable(visible)
PMMA.
Configuration for BYKG-III-IV-V: Constituted of cold steel finished with
electrostatic coating.
Work desk: Stainless steel.
Main units connected flexibly with features of small tremble & low
noise.
The whole configuration more reasonable and ergonomic.
One HEPA filter.
Filter efficiency: 99.999%(0.3m).
Display the pressure differential in HEPA filter, audible &visible.
Blower fan bearing unlimited speed gear.
Centrifugal fan, low noise and energy consumption, capable offunctioning without maintenance.
Air velocity: 0.75 m /s ~ 1.0m/s.
Air dust blowing vertical.
Air velocity of blower: adjustable.
Workroom Interior.
Lighting: For BYK-I-II >500lux, For BYK-III-IV-V >650lux.
UV Lamp: Sterilizing by UV lamp. It adopts High-intensity, long life,
Ozone-free UV lamp.
External size(LxWxH): BYKG-I: 550x465x780mm,
BYKG-II:700x550x900mm, BYKG-III: 900x695x1000mm,
BYKG-IV:1000x695x1720mm, BYKG-V:1100x695x1924mm.
Internal size(LxWxH): BYKG-I: 540x385x400mm,BYKG-II: 680x450x500mm, BYKG-III:768x690x580mm,
BYKG-IV: 868x690x630mm, BYKG-V: 968x695x630mm.
Noise: For BYK-I-II
7/29/2019 Especificaciones Tecnicas Fume Hood
3/7
118
F FUME HOOD Laminar AirFlowBBS-13HGS/BBS13VGS, Laminar Airflow Cabinets
Model BBS13HGS BBS13VGS
External Dimen.(mm) L1300xW750xH2000L1310xW825xH2000
including the base stand
Working zone size(mm) L1200xW645xH610 L1200xW500xH570
HEPA Filter dimen.(mm) L1223xW570xH69Display Digital airflow display
Hepa filterHepa filter with 99.997%efficiency at 0.3 micros
HEPA filter, the filtrationperformance: 99.99% to 0.5 um
Dust 3.5 Granule/L for 0.5um
Noise level 60db
Airflow Horizontal, 0.3-0.5m/s Vertical, 0.3-0.5m/s
Vibration level XYZ direct 99.995% (for 0.3 um)
Air velocity 0.3-0.5m/s
Noise
7/29/2019 Especificaciones Tecnicas Fume Hood
4/7
119
FFUME HOOD
BSC11A Class I BYKG-II-IV-V Class I
Biosafety Performance Biosafety, and operators safety: impact sampling colony
number 10CUF/time. Slit sampling colony number 5CUF/time. Product safety: colony number 5CUF/time. Cross contamination: colony number 2CUF/time.
HEPA Filter Leak Proof The filterability of every point measuring the filterablesubstance that can be scanned and detected is nomore than 0.01 %.
The filterability of every point measuring the filterablesubstance that can't be scanned and detected is nomore than 0.005%.
Material Operation interior surface is made of 300 series
stainless steel. Front panel is made of toughened glass, which won't
be negative effected by cleaning and sterilization.
Thickness of front panel is no less than 5mm. For 0.3m particulate, the filter efficiency is
99.999%, which meet the demand of temperature,humidity, corrosion proof and mechanical strength.
Filter material is made of superfine fiberglass, whichwill not cause adverse impact on personnel,environment and facility.
Front Operation Area The structure of front panel avoids danger to operator
when sliding system can't work correctly. Alarm device assure the safety of experiments in the
specialized range.
Biological Safety Cabinets Each cabinet is tested by college of military science. Environment test: cabinets are tested under the cruel
environment range from -40C-50C, and humidity rangefrom 5%-100%.
Exclusive Four Patents New appearance. Remote control. Reserve timing. High light VFD display.
Motor Thermal protection device assure the steady in 1.15 times of
voltage rating. Actiyator is installed behind the demountable or locktabe
control panel.
Biological Safety Cabinet
BYKG-I-II Class I
BSC13IIA2X Class II BSC7IIA2 Class II BSC15IIIX Class III
7/29/2019 Especificaciones Tecnicas Fume Hood
5/7
120
F FUME HOOD Biological Safety Cabinet
Model BSC13IIA2X BSC18IIA2X BSC11IIA2X BSC11IIB2X
External size(mm) W1300xD850xH2200 W1800xD850xH2200 W1100xD850xH2200 W1100xD850xH2200
Internal size(mm) W1100xD600xH660 W1600xD600xH660 W970xD600xH660 W970xD600xH660
Material Work zone interior is made of 304 stainless steel expoxy coated cold rolled steel
Control system Microprocessor
Display LED display
Main filter Hepa filter with 99.999% efficiency at 0.3 micros
Exhaust filter Hepa filter with 99.999% efficiency at 0.3 micros
Intake airflow velocity 0.53m/s 0.65m/s0.015m/s 0.65m/s0.015m/s
Exhaust airflow velocity 0.33m/s 0.37m/s0.015m/s 0.37m/s0.015m/s
Air circulation 70% 30% 0
Air exhaust 30% 70% 100%
Front Panel Sliding by electronic control, double layer toughened glass
Clean level Class 100
Noise level 65db
Lightning 680Lux 800Lux ~ 1100Lux
UV lamp 15W x 1
Collecting tank 4000ml, fitted with draining valve
Power 220V, 50Hz 10% 110V~ 240V/50Hz~60Hz (optional)
Class II, A2 II, B2
BSC13IIA2X/BSC18IIA2X/ BSC11IIA2X/BSC11IIB2X, Class II
The Class II Biological Safety Cabinet is designed with inward air flow at
a velocity to protect personnel, HEPA-filtered vertical laminar airflow for
product protection, and HEPA-filtered exhausted air for environmental
protection.
CE,ISO1
3485
ISO9001
,ISO1400
1
CE,ISO1
3485
ISO9001
,ISO1400
1
7/29/2019 Especificaciones Tecnicas Fume Hood
6/7
121
FFUME HOOD
BSC15IIIX/ZX/KX, Class III
Model BSC15IIIX BSC15IIIZX BSC15IIIKX
External Dimensions (mm) L1340xW850xH2250 L1645xW850xH2250 L1950xW850xH2250
Internal Dimension (mm) L1240xW650xH650 L1545xW650xH650 L1850xW650xH650
No. of gloves 2 4 4
Delivery window dimension(mm) L480xW400xH400
Interception efficiency 99.999% (for 0.12m particulates)
Noise level
7/29/2019 Especificaciones Tecnicas Fume Hood
7/7
122
F
The only thing basic about the MRC BacBASIC is its very
reasonable price.
The BacBASIC is the ideal, entry level chamber forperformance of truly anaerobic microbiology. Move beyond jars
and the unnecessary exposure of your anaerobes to deadly
oxygen.
Already have a chamber? Then the BacBASIC offers the
perfect auxiliary chamber option for over-ow work, extra plate
storage and emergency back-up for your primary chamber.
BacBasic, Environmental Work Station &Incubator For Anaerobic Applications
Exterior Dimensions(mm) W890xD750xH750
Interior Dimensions(mm)
W820xD490xH560
Weight 103kg
Temperature Range Ambient to 42C
Temperature Uniformity +/- 0.5C
Ergonomic,
Gum Drop * Arm Port
Doors offer
maximum reach &
comfort!
*ARM PORT DOOR
DESIGN PATENT
PENDING
Removable
viewing shield for
introduction of equipment,
cleaning,
decontaminationor maintenance.
BacBasic
The MRC BacBASIC offers:An ample, ergonomic, user-friendly work station with
a minimal, space-saving exterior footprint.Excellent lighting and visibility.A quick-entry, gloveless sleeve system.A rapid* Auto-Purge Pass Box for introducing Petri
plates, specimens & supplies.(*Purge time less than 50 sec.)
Incubated storage capacity for up to 150 Petri plates.Incubation temp. range from ambient temp. to 42C.Easy-Change anatox & catalyst packs & the catalyst
can be used for up to six months before replacementor reactivation.
Central Pass
Through BoxSimple Push
Button Operation
Interior Auto-
Purge ButtonEasy Change
Anatox
& Catalyst
Packs
Anaerobic ChambersFUME HOOD