e-STUDIO6530c Series USB Firmware Update Print Queue Warning All pending jobs in the print queue must be cleared prior to doing this update. Jobs that are in the Private Print queue prior to the update will have the User Name and File Name modified such that the jobs cannot be printed after the update. Before doing the update, release all jobs in the USB, Hold and Proof queues. Have the job owners release the jobs in the Private queue. The Administrator can delete the jobs in the Private Queue but the Administrator cannot print them. Additional Information Update Instructions We have attached the pages from the Service Handbook describing how to perform the firmware Update. At this time, there are no changes from the information in the Handbook regarding the update. Adjustments Required Please note the additional adjustments required after completing the firmware update as described on page 8-11 mentusb2.o This model uses a mentusb2.o instead of the mentusb.o earlier products. This mentusb2.o must be placed in the root of the USB. If you are sharing the USB device between the e-STUDIO4520 series and machines that use mentusb.o, you should put both files in the USB root. Filesystem You can format the USB as FAT or FAT32. If you format as FAT32, you cannot share the USB key with the prior generation of e-Brdige machines as these MFPs requires a USB formatted as FAT.

Es6530c Update Inst v03

Embed Size (px)

Citation preview

Page 1: Es6530c Update Inst v03

e-STUDIO6530c Series USB Firmware Update

Print Queue Warning All pending jobs in the print queue must be cleared prior to doing this update. Jobs that are in the

Private Print queue prior to the update will have the User Name and File Name modified such

that the jobs cannot be printed after the update.

Before doing the update, release all jobs in the USB, Hold and Proof queues. Have the job

owners release the jobs in the Private queue. The Administrator can delete the jobs in the Private

Queue but the Administrator cannot print them.

Additional Information

Update Instructions

We have attached the pages from the Service Handbook describing how to perform the firmware

Update. At this time, there are no changes from the information in the Handbook regarding the

update.

Adjustments Required

Please note the additional adjustments required after completing the firmware update as

described on page 8-11

mentusb2.o

This model uses a mentusb2.o instead of the mentusb.o earlier products. This mentusb2.o must

be placed in the root of the USB. If you are sharing the USB device between the e-STUDIO4520

series and machines that use mentusb.o, you should put both files in the USB root.

Filesystem

You can format the USB as FAT or FAT32. If you format as FAT32, you cannot share the USB

key with the prior generation of e-Brdige machines as these MFPs requires a USB formatted as

FAT.

Page 2: Es6530c Update Inst v03

e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

8 - 4

8.1 Firmware Updating with USB MediaFirmware can be updated by storing update programs and firmware data files in the USB media.

Program necessary for updating

Firmware type and data file name for updating

Store the update program loader (mentusb2.o) in the root directory, and store the model specific update program (dlFirmWare_5520C_6530C) and the data file for updating in the model specific folder.

Note: Never change the model specific folder name, since it is used for identifying the data file when the data files used for updating multiple models are stored in the USB media.

Update program Data file name RemarksUpdate program loader mentusb2.o An error occurs at a time of the [4] + [9]

startup, unless this program is stored in the USB media.* Be sure to save this data file to the

root directory of the USB media.Model specific update program dlFirmWare_5520C_6530C An error occurs at a time of the [4] + [9]

startup, unless this program is stored in the USB media.

Firmware Stored Data file name RemarksSystem ROM System control PC

board(SYS board)

firmImage0.bin OS data

Master data Hard disk hdd.bin HDD program data, System firmware, UI data

PFC ROM Paper feeding control board(PFC board)

T430FWW.xxx* xxx is version.

PFC firmware

Engine ROM Logic PC board(LGC board)

T430MWW.xxx* xxx is version.

Main firmware

Scanner ROM Scanning section con-trol PC board(SLG board)

T430SLGWW.xxx* xxx is version.

Scanner firmware

Model specific folder name 5520C_6530C

5520C_6530C

dlFirmWare_5520C_6530C

mentusb2.o

T430MWW.xxx

T430FWW.xxxT430SLGWW.xxx

firmImage0.binhdd.bin

USB media

Page 3: Es6530c Update Inst v03

8

© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530CFIRMWARE UPDATING

8 - 5

Important: • Only the USB media which meet the following conditions should be used for updating. Be

careful since updating with any device other than the above is never guaranteed.- A combination USB media with a flash memory (to be connected directly to the USB port)

and its capacity is between 256 MB and 512 MB (or 1 GB).- Operation of the USB media used for updating has been confirmed at the input check of

this equipment (Test mode 03).( P.2-4 "2.1 Input check (Test mode 03)")

- USB media which comply with the following standards regulated by USB-IF (USB Imple-menters Forum)Class number: 8 (=08h) (Mass-storage class)Sub-class number: 6 (=06h) (SCSI transfer command set)Protocol number: 80 (=50h) (Bulk-Only)* Most common USB media comply with the specification above and can be used for

updating. However, the operation in all the Multi Functional Digital Color Systems and Multi Functional Digital Systems is not necessarily guaranteed since the most of these devices are developed based on use in a PC environment (Windows or Macintosh). Therefore, check thoroughly that the device is operational in the equipment for which the updating will be performed when purchasing it.

• The USB media complying with USB1.1 and USB2.0 can be used for updating.

• Do not update the firmware by any storage device other than a flash memory (such as a USB connection type memory card reader, CD/DVD drive or hard disk), since it is never guaran-teed.

• It is possible to store the model specific update program and the data file for updating directly in the root directory when you store the updating data file for one specific model in the USB media. However, if the model specific folder for the same model as that of the data file stored in the root directory already exists, this will have priority.

Page 4: Es6530c Update Inst v03

e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

8 - 6

8.1.1 Master data/System ROM/PFC ROM/Engine ROM/Scanner ROMImportant:

• The file system of USB media should be formatted in the FAT or FAT32 format. Be careful since the devices formatted in NTFS format will not be able to be operated. The file system can be confirmed on the properties in applications such as Explorer of Windows.

• Never shut down the equipment during the update. Firmware data and the following option data (if installed) could be damaged and may not be able to be operated properly.- Data Overwrite Enabler (GP-1070)- Meta Scan Enabler (GS-1010)- External Interface Enabler (GS-1020)- IPSec Enabler (GP-1080)

[A] Update procedure

(1) Connect the USB media to the PC and write the model specific folder in which the data file is stored.Store the update program loader (mentusb2.o) in the root directory, and store the model specific update program (dlFirmWare_5520C_6530C) and the data file for updating in the model specific folder.

(2) Press the [ON/OFF] button on the control panel to shut down the equipment.

(3) Connect the USB media to the USB port on the right upper cover.

Fig. 8-1

Note: Updating cannot be performed with multiple USB media connected at the same time.

USB media

USB port

Before starting, record the valuein 08 code 206 (Sleep Mode Timer). The firmware update mayreset this value.

Page 5: Es6530c Update Inst v03

8

© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530CFIRMWARE UPDATING

8 - 7

(4) Press the [ON/OFF] button while simultaneously holding down the [4] and [9] buttons.Data in the USB media are checked and the checking status is displayed on the screen.

The screen for selecting items to be updated is displayed after approx. 1 minute. On this screen, the current firmware version of this equipment and the firmware version of data to be updated are displayed.

Fig. 8-2

Notes: • The display of items on this screen varies depending on the types of data written on the USB

media. Each item is displayed only when each data file is written on the USB media in the fol-lowing conditions.

• If the USB media are not recognized properly, "Set Correct USB Storage Device" message is displayed. In this case, disconnect the USB media and connect it again within 3 minutes, or shut down the equipment and connect the device properly. Then repeat the procedure from (4).

• If any of the error messages below is displayed, confirm if the update program or the data file in the USB media is correct. Then repeat the procedure from (4)

Item Condition1. OS Update firmImage0.bin is written.

2. HDD SYS Update hdd.bin is written.

3. PFC Firmware Update T430FWW.xxx is written. (xxx is version.)

4. Engine Main Firmware Update T430MWW.xxx is written. (xxx is version.)

5. Scanner Firmware Update T430SLGWW.xxx is written. (xxx is version.)

Error number Error message Cause

- There is no mentusb2.o Update program loader (mentusb2.o) is not stored.

01 There is no dlFirmWare_5520C_6530C Model specific update program (dlFirmWare_5520C_6530C) is not stored.

02 Error Loadmodule Module loading failed.

03 Machine Model Get Error Model information was not downloaded.

04 Please Change USB Storage or Please Check ROMDATA

Checking of data file failed.

05 Other models ROMDATA Vxxxx.xxx x* The version name comes at “xxxx.xxx.x”.

Master data of other model (hdd.bin) are stored.

Page 6: Es6530c Update Inst v03

e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

8 - 8

(5) Select the item with the digital keys.“*” is displayed next to the selected item. Display or delete the “*” by pressing the number of the item.

(6) Press the [START] button.Updating starts and the processing status is displayed on the LCD screen.

(7) “Update Completed.” is displayed at the bottom of the LCD screen after the updating is com-pleted properly.

Fig. 8-3

Notes: • “Update Failed.” is displayed at the bottom of the LCD screen when the updating is not com-

pleted properly. “Failed” appears next to the failed item on the status display. Turn OFF the power, and then check the following items. After confirming and clearing the problems, restart updating from the beginning.- Do the USB media meet the conditions to be used for updating?- Is the data file written properly on the USB media?- Are the USB media installed properly?- Do the USB media and equipment operate properly?

Item Remarks1. OS Update Updating OS data and UI data2. HDD SYS Update Updating Master data and System data3. PFC Firmware Update Updating PFC ROM4. Engine Main Firmware Update Updating Engine ROM5. Scanner Firmware Update Updating Scanner ROM

Status display during update Status display when update is completed OS Update...........................FROM write OS Update...........................CompletedHDD SYS Update ............... Copy file HDD SYS Update ............... CompletedPFC Firm Update ................Flash Update PFC Firm Update ................CompletedEngine Firm Update.............Flash Update Engine Firm Update.............CompletedScanner Firm Update ..........Flash Update Scanner Firm Update ..........Completed

Page 7: Es6530c Update Inst v03

8

© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530CFIRMWARE UPDATING

8 - 9

• When an error occurred and the update failed, "Update Failed" or "Failed" appears on the screen and an error code appears next to the message. The content of each error code is shown below.

OS update ErrorError number Error content

O01 FROM writing failed

O02 FROM verification error

O03 File operation error

O04 SRAM flag set error

O05 Electronic key data backup error

O06 Device error

HDD update ErrorError number Error content

H01 File creation error

H02 File decompression error

H03 Partition mount error

H00 Other errors

Engine Update ErrorError number Error message Error content

M01 Time out(When the download is requested)

Communication timeout(When the download is requested)

M02 Time out(When the download is written)

Communication timeout(When the download is written)

M03 Time out(When the download is finished)

Communication timeout(When the download is finished)

M04 Reception failed(When the download is requested)

Downloading request was denied.(When the download is requested)

M05 Deletion error(When the download is written)

Deletion error(When the download is written)

M06 Writing error(When the download is written)

Writing error(When the download is written)

M07 Checksum error(When the download is finished)

Checksum error(When the download is finished)

M08 Reception status code abnormality(When the download is requested)

Reception status code abnormality(When the download is requested)

M09 Reception status code abnormality(When the download is written)

Reception status code abnormality(When the download is written)

M10 Reception status code abnormality(When the download is finished)

Reception status code abnormality(When the download is finished)

M00 Other error Other error

Page 8: Es6530c Update Inst v03

e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

8 - 10

(8) Press the [ON/OFF] button to shut down the equipment, and then remove the USB media.

(9) Perform the initialization of the updating data.• Turn ON the power while [0] button and [8] button are pressed simultaneously.• Key in “947”, and then press the [START] button.• Press the [INITIALIZE] button.

PFC Update ErrorError number Error message Error content

F01 Time out(When the download is requested)

Communication timeout(When the download is requested)

F02 Time out(When the download is written)

Communication timeout(When the download is written)

F03 Time out(When the download is finished)

Communication timeout(When the download is finished)

F04 Reception failed(When the download is requested)

Downloading request was denied.(When the download is requested)

F05 Deletion error(When the download is written)

Deletion error(When the download is written)

F06 Writing error(When the download is written)

Writing error(When the download is written)

F07 Checksum error(When the download is finished)

Checksum error(When the download is finished)

F08 Reception status code abnormality(When the download is requested)

Reception status code abnormality(When the download is requested)

F09 Reception status code abnormality(When the download is written)

Reception status code abnormality(When the download is written)

F10 Reception status code abnormality(When the download is finished)

Reception status code abnormality(When the download is finished)

F00 Other error Other error

Scanner Update ErrorError number Error message Error content

S01 Time out(When the download is requested)

Communication timeout(When the download is requested)

S02 Time out(When the download is written)

Communication timeout(When the download is written)

S03 Time out(When the download is finished)

Communication timeout(When the download is finished)

S05 Deletion error(When the download is written)

Deletion error(When the download is written)

S06 Writing error(When the download is written)

Writing error(When the download is written)

S08 Reception status code abnormality(When the download is requested)

Reception status code abnormality(When the download is requested)

S09 Reception status code abnormality(When the download is written)

Reception status code abnormality(When the download is written)

S10 Reception status code abnormality(When the download is finished)

Reception status code abnormality(When the download is finished)

S00 Other error Other error

Check the value in 08 code 206 and restore the original value if necessary.

Page 9: Es6530c Update Inst v03

8

© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530CFIRMWARE UPDATING

8 - 11

[B] Confirmation of the updated dataAfter the updating is completed, check each data version in the Setting Mode (08) to confirm that the data were overwritten properly.

P.8-44 "8.4 Confirmation of the updated data"

[C] AdjustmentPerform the adjustment of the equipment.

• Performing Image Quality Control (05-396): P.3-5 "3.1.3 Performing Image Quality Control"

• Adjustment of Color Registration Control (05-4719): P.3-7 "3.1.4 Adjustment of Color Registration Control"

• Automatic gamma adjustment <PPC> (05-1642) (using [4][FAX] test pattern): P.3-32 "3.2.1 Automatic gamma adjustment"

• Automatic gamma adjustment < PRT > (05-1008) (using [70][FAX] test pattern): P.3-47 "3.3.1 Automatic gamma adjustment"

[D] Display during the updateUpdate is performed in parallel as shown in the transition diagram below.

3. PFCFirmware Update

4. Engine MainFirmware Update

5. Scanner

Firmware Update1. OS Update 2. HDD SYS Update

Item Selection Screen for Update

[System ROM] [Master data] [Engine ROM] [Scanner ROM]

Update Completed

Page 10: Es6530c Update Inst v03

e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

8 - 12

Below is an example of the changes of the LCD screen during update.System ROM

Fig. 8-4

Page 11: Es6530c Update Inst v03

8

© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530CFIRMWARE UPDATING

8 - 13

Master data

Fig. 8-5

Page 12: Es6530c Update Inst v03

e-STUDIO5520C/6520C/6530C © 2008 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

8 - 14

Scanner ROM

Fig. 8-6

Page 13: Es6530c Update Inst v03

8

© 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5520C/6520C/6530CFIRMWARE UPDATING

8 - 15

PFC ROM / Engine ROM

Fig. 8-7