5
ELECTRICAL ABBREVIATIONS A AF AFF AFG AFI AIC AL ARCH AS AWG BLDG BKBD C CAB CAT C/B CKT CLG CO COMM CONN CU DEMO DISC DN DWG EA ELEC ELEV EMER, EM EMT EOLR EQUIP EX, EXIST FBO FCU FF FIXT FLEX FLUOR FT GFI GND HP HVAC IG IMC IN ISC JB, J-BOX KCMIL KVA KW AMPERE AMP FUSE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ARC-FAULT CIRCUIT-INTERRUPTER AMPERE INTERRUPTING CAPACITY ALUMINUM ARCHITECT(URAL) AMP SWITCH AMERICAN WIRE GAUGE BUILDING BACKBOARD CONDUIT CABINET CATALOG/CATEGORY CIRCUIT BREAKER CIRCUIT CEILING CONDUIT ONLY COMMUNICATION CONNECTION COPPER DEMOLITION/DEMOLISH DISCONNECT DOWN DRAWING EACH ELECTRICAL ELEVATOR EMERGENCY ELECTRICAL METALLIC TUBING END OF LINE RESISTOR EQUIPMENT EXISTING FURNISHED BY OTHERS FAN COIL UNIT FINISHED FLOOR FIXTURE FLEXIBLE METALLIC CONDUIT (STEEL) FLUORESCENT FEET OR FOOT GROUND FAULT INTERRUPTER GROUND HORSEPOWER HEATING, VENTILATING & AIR CONDITIONING ISOLATED GROUND INTERMEDIATE METAL CONDUIT INCH(ES) SHORT CIRCUIT AMPERES, KA JUNCTION BOX THOUSAND CIRCULAR MILS KILOVOLT AMPERE KILOWATT LTG MAX MCB MECH MFR MIN MLO MTD NEC NECA NEMA NEUT NFC NC NIC NL NO NTS OCP P PH PNL PWR QTY RECEP REQ'D RGSC RM SCHED SECT SP SN SPEC SW SWBD SWGR SYS TEMP TELE XFMR T-STAT TWP TWSP TYP UBC UL UMC UNO V VA W W/ WG WP LIGHTING MAXIMUM MAIN CIRCUIT BREAKER MECHANICAL MANUFACTURER MINIMUM MAIN LUGS ONLY MOUNTED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL CONTRACTOR'S ASSOCIATION NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NEUTRAL NATIONAL FIRE CODE NORMALLY CLOSED NOT IN CONTRACT NIGHT LITE NORMALLY OPEN NOT TO SCALE OVERCURRENT PROTECTION POLE PHASE PANEL POWER QUANTITY RECEPTACLE REQUIRED RIGID GALVANIZED STEEL CONDUIT ROOM SCHEDULE SECTION SINGLE POLE SOLID NEUTRAL SPECIFICATION SWITCH SWITCHBOARD SWITCH GEAR SYSTEM TEMPORARY TELEPHONE TRANSFORMER THERMOSTAT TWISTED PAIR TWISTED SHEILDED PAIR TYPICAL UNIFORM BUILDING CODE UNDERWRITERS LABORATORY UNIFORM MECHANICAL CODE UNLESS NOTED OTHERWISE VOLT OR VOLTAGE VOLT AMPERE WATT WITH WIRE GUARD UL LISTED WEATHERPROOF, NEMA 3R or 4 S P 3 4 X 3ØUP 3ØUS UT UTV SITE ELECTRICAL "x" POLE SWITCH - ARC FAULT INTERRUPTER WALL MOUNT FIXTURE THREE WAY SWITCH FOUR WAY SWITCH WALL MOUNT OCCUPANCY SENSOR: ADAPTIVE TECHNOLOGY OCCUPANCY SENSOR PHOTOCELL QUANTITY OF CONDUCTORS: SHORT LINES = PHASE /SWITCH, LONG LINES = NEUTRAL HOME-RUN DISTRIBUTION PANEL PANELBOARD 3-PHASE UNDERGROUND PRIMARY POWER 3-PHASE UNDERGROUND SECONDARY POWER UNDERGROUND TELEPHONE UNDERGROUND TV POINT OF DISCONNECTION POINT OF CONNECTION OT OVERHEAD TELEPHONE 1ØOP 1-PHASE OVERHEAD PRIMARY POWER DIMMER SWITCH: INCANDESCENT; 1000 W MINIMUM F DIMMER SWITCH: FLUORESCENT; 100 W MINIMUM P PILOT LIGHT SWITCH POLE LIGHT; ONE HEAD POLE LIGHT; TWO HEAD DECORATIVE POLE LIGHT TIME CLOCK POWER AND DISTRIBUTION LIGHTING FIXTURES LIGHTING CONTROL BRANCH CIRCUITING ELECTRICAL LEGEND SINGLE POLE SWITCH; "x" INDICATES SWITCH GROUP X OTV OVERHEAD TV METER / METER SOCKET S OCCUPANCY SENSOR: DUAL TECHNOLOGY S OCCUPANCY SENSOR: PASSIVE INFRARED S OCCUPANCY SENSOR: ULTRASONIC DT PR US 1ØUP 1ØUS 1-PHASE UNDERGROUND PRIMARY POWER 1-PHASE UNDERGROUND SECONDARY POWER UTILITY POLE PUSH BUTTON L DIMMER SWITCH: LED; 600 W MINIMUM S OCCUPANCY SENSOR: # INDICATES WATTSTOPPER CAT# FOR COVERAGE PATTERN OR EQUIVALENT AS SPECIFIED # DETAIL CALL-OUT; TOP "X" REFERS TO DETAIL NUMBER & BOTTOM "XXX" REFERS TO SHEET NUMBER ANNOTATIONS XXX X 3ØOP 3ØOS 3-PHASE OVERHEAD PRIMARY POWER 3-PHASE OVERHEAD SECONDARY POWER (E)3ØOP 3-PHASE OVERHEAD PRIMARY POWER : EXISTING 3-PHASE UNDERGROUND PRIMARY POWER : EXISTING (E)3ØUP (E)UT UNDERGROUND TELEPHONE : EXISTING DL SWITCH: DAYLIGHT ZONE AS DETAILED 2P SWITCH: SINGLE-THROW; DOUBLE-POLE LSX/SY DIGITAL LIGHTING CONTROL SWITCH; SX = SWITCH CONTROL TYPE #1; SY = SWITCH CONTROL TYPE #2; ETC. P PHOTOCELL: INTEGRATED TO LIGHTING CONTROL SYSTEM; P# = LIGHTING CONTROL TYPE P# S OCCUPANCY SENSOR: LIGHTING CONTROL SYSTEM; O# = LIGHTING CONTROL TYPE LO# S OCCUPANCY SENSOR: HIGH BAY HB 3-PHASE UNDERGROUND PRIMARY POWER: DEMO 3-PHASE UNDERGROUND SECONDARY POWER: DEMO (D)3ØUP (D)3ØUS 3-PHASE UNDERGROUND SECONDARY POWER : EXISTING (E)3ØUS (D)UT UNDERGROUND TELEPHONE : DEMO (D)UTV UNDERGROUND TV : DEMO (E)UTV UNDERGROUND TV : EXISTING P PHOTOCELL: DAYLIGHT RESPONSIVE FOR CONTINUOUS DIMMING APPLICATIONS. DR 1ØUF 1-PHASE UNDERGROUND FEEDER DIMMER SWITCH WITH WALL MOUNT OCCUPANCY SENSOR: ADAPTIVE TECHNOLOGY # KEYED NOTE CALLOUT EQUIPMENT CALLOUT K SWITCH: KEYED PRODUCTION EQUIPMENT CALLOUT #-# #-# WALL MOUNT OCCUPANCY SENSOR: VACANCY SENSOR FUNCTION S OCCUPANCY SENSOR: VACANCY SENSOR FUNCTION VS WALL MOUNT OCCUPANCY SENSOR: OCCUPANCY SENSOR FUNCTION S OCCUPANCY SENSOR: OCCUPANCY SENSOR FUNCTION OS VS OS 1ØOS 1-PHASE OVERHEAD SECONDARY POWER 3ØOT 3-PHASE OVERHEAD TRANSMISSION LINES GENERAL PROJECT NOTES 1. ALL ELECTRICAL INSTALLATIONS TO CONFORM TO THE LATEST NEC AND LOCAL CODES. 2. ELECTRICAL CONTRACTOR'S PROJECT MANAGER AND ON-SITE PROJECT FOREMAN SHALL REVIEW VENDOR SUBMITTALS FOR ACCURACY PRIOR TO SUBMITTING TO ENGINEER. INACCURACIES SHALL BE CORRECTED PRIOR TO ENGINEER SUBMITTAL. 3. SUBMITTALS FOR EACH SYSTEM WILL BE REVIEWED BY ENGINEER UP TO TWO TIMES--ONE FULL SUBMITTAL FOR OVERALL COMPLIANCE AND ONE RESUBMITTAL. ADDITIONAL REVIEWS WILL BE CHARGED TO CONTRACTOR AT ENGINEER'S STANDARD BILLING RATE. 4. SUBMITTALS TO ENGINEER SHALL INCLUDE ALL SPECIFIED SYSTEMS IN FIRST SUBMITTAL. PARTIAL SUBMITTALS WILL BE RETURNED TO CONTRACTOR AS INCOMPLETE AND WILL BE CONSIDERED ONE OF TWO INCLUDED SUBMITTAL REVIEWS. 5. THE CLARITY OF RECORD DRAWING CHANGES MADE BY THE CONTRACTOR SHALL BE EQUAL TO THE ORIGINAL DRAWINGS AS JUDGED BY THE ARCHITECT OR THE RECORD SET WILL BE RETURNED TO THE CONTRACTOR FOR CLARIFICATION. 6. WHEN THE GENERAL CONTRACT CALLS FOR “RECORD” OR “AS-BUILT” DRAWINGS TO BE FURNISHED BY THE CONTRACTOR AT JOB COMPLETION, THE ELECTRICAL CONTRACTOR SHALL BE REQUIRED TO FURNISH A COMPLETE SET OF “BLUE-PRINT READY” AUTOCAD ELECTRICAL DRAWINGS FOR ALL CONTRACTOR GENERATED CHANGES FROM THE DRAWINGS OF A CLARITY EQUAL TO THE ORIGINAL DRAWINGS AS JUDGED BY THE ENGINEER. CONTACT ARCHITECT FOR DISKS OR REPRODUCIBLE ORIGINAL MEDIA. PROVIDE DRAWINGS ON CD IN AUTOCAD FORMAT. 7. DO NOT SCALE ELECTRICAL FLOOR OR SITE PLANS. SEE ARCHITECTURAL DRAWINGS FOR ACCURATE BUILDING DIMENSIONS AND FIELD VERIFY ALL EXTERIOR DIMENSIONS. 8. ELECTRICAL DEVICES CANNOT BE SHOWN TO SCALE AND SOMETIMES OVERLAP BUILDING AND SITE ELEMENTS. REFER TO ARCHITECTURAL ELEVATIONS FOR ACCURATE MOUNTING LOCATIONS 9. EMT IS NOT ALLOWED OUT OF DOORS. 10. DO NOT INSTALL IN-GRADE JUCTION BOXES UNLESS SPECIFICALLY SHOWN ON DRAWINGS. CONDUCTORS SHALL BE RUN CONTINOUS WITHOUT SPLICING FROM SOURCE OR DEVICE TO NEXT DEVICE. 11. CIRCUIT WIRE SIZES MUST MATCH BRANCH CIRCUIT BREAKERS PER NEC. VERIFY WITH PANEL SCHEDULES BEFORE PULLING WIRE. 12. HOME RUNS MUST BE RUN EXACTLY AS SHOWN ON PLANS UNLESS OTHERWISE NOTED. DO NOT COMBINE HOME RUNS INTO ONE CONDUIT THAT ARE NOT SHOWN COMBINED ON THE DRAWINGS. 13. THE ELECTRICAL CONTRACTOR SHALL RUN BRANCH CIRCUIT CONDUITS IN ATTIC SPACES IN A NEAT AND WORKMANLIKE MANNER SO AS TO CONSERVE OPEN SPACES AS MUCH AS POSSIBLE. HVAC DUCTWORK AND PLUMBING SHALL HAVE LOCATION PRIORITY OVER BRANCH CIRCUIT CONDUIT RUNS. 14. CIRCUIT WIRING SHALL BE INSTALLED AS SHOWN ON THE DRAWINGS. ANY DEVIATIONS SHALL BE INITIATED BY A CHANGE ORDER FROM THE ARCHITECT. OTHERWISE THE RECORD SET SHALL MATCH THE CONSTRUCTION SET. 15. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR, PULLED INTO THE CONDUIT WITH THE PHASE CONDUCTOR, IN ALL SERVICE, FEEDER, AND BRANCH CIRCUITS. 16. PROVIDE A NEUTRAL CONDUCTOR FOR EACH BREAKER TRIP HANDLE. NEUTRALS SHALL NOT BE SHARED BETWEEN BRANCH CIRCUITS. 17. ALL SITE LIGHTING CIRCUITS TO BE MINIMUM #12 CU IN MINIMUM 3/4” CONDUIT UNLESS OTHERWISE NOTED. 18. MC CABLE IS NOT AN APPROVED ALTERNATE TO CONDUCTORS IN CONDUIT. 19. DO NOT INSTALL MORE THAN THREE PHASE CONDUCTORS IN ANY HOME-RUN CONDUITS UNLESS SPECIFICALLY INDICATED ON DRAWINGS. 20. INCLUDE AS PART OF THE JOB THE INSTALLATION OF AN EXTRA 200 FT OF 3/4” EMT WITH 4 #10 WIRES INSTALLED AND TWO J-BOX TERMINATIONS. 21. REMOVE ALL OLD AND/OR UNUSED EXISTING CONDUIT AND ELECTRICAL APPARATUS FROM EXTERIOR OR INTERIOR EXPOSED SURFACES. 22. WHERE EXISTING ELECTRICAL EQUIPMENT IS TO REMAIN BUT THE SURFACE THAT IT IS MOUNTED ON IS TO BE REWORKED UNDER OTHER CONTRACTS, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND INSTALL OR MODIFY THE EXISTING EQUIPMENT AS REQUIRED TO MEET THE DESIGN INTENT. SEE ARCHITECTURAL DRAWINGS FOR ROOF, CEILINGS, WALLS, SOFFITS, FLOORS, ETC. 23. REMOVE ALL UNUSED CONDUITS AND CIRCUITS IN THE DEMOLTIONED AREA AS THEY ARE IDENTIFIED AS UNUSED OR ABANDONED. 24. REMOVE ALL EXISTING ELECTRICAL DEVICES, EQUIPMENT, AND APPARATUS AS THEY ARE IDENTIFIED AS UNUSED OR ABANDONED. 25. RELOCATE EXISTING CONDUITS AND CIRCUITS AS REQUIRED THAT ARE PRESENTLY SERVING EQUIPMENT THAT IS INTENDED TO REMAIN IN SERVICE BUT SAID CONDUITS ARE CURRENTLY RUNNING THROUGH AREAS TO BE DEMOLITIONED. 26. WHERE EXISTING CONDUIT RUNS ARE RE-USED BY SPECIAL PERMISSION FROM THE ARCHITECT, A SEPARATE GREEN, INSULATED GROUND WIRE SHALL BE PULLED IN THE CONDUIT AND BONDED AT EACH END AS REQUIRED. 27. ALL PATCH, REPAIR, REPAINT AND COVER UP REQUIRED AS A RESULT OF ELECTRICAL REMODEL IS TO BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, BUT ACTUAL WORK IS TO BE PERFORMED BY QUALIFIED PERSONNEL. 28. FIELD VERIFY CONDITIONS FOR NEW WIRING. SURFACE RACEWAYS MUST RECEIVE PRIOR APPROVAL FROM THE ARCHITECT BEFORE BID AND MUST BE PAINTED TO MATCH THE SURFACE ON WHICH THEY ARE MOUNTED. 29. PROVIDE NEUTRAL CONNECTION TO 208/240/480V, SINGLE-PHASE EQUIPMENT. RUN SEPARATE GROUND WIRE TO ALL OUTDOOR UNITS AND BOND TO THE EQUIPMENT GROUND LUG. 30. REVIEW THE STATE DESIGN REQUIREMENTS MANUAL PRIOR TO BID. 31. REVIEW THE USU A&E DESIGN MANUAL PRIOR TO BID. 32. WHERE THERE ARE CONFLICTS IN THE DRAWINGS AND/OR SPECIFICATIONS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER PRIOR TO BID. WHERE NO NOTIFICATION IS GIVEN THE MORE STRINGENT INTERPRETATION (GENERALLY INTERPRETED TO BE THE MORE COSTLY) WILL BE ENFORCED. 3 6 0 w e s t a s p e n a v e n u e s a l t l a k e c i t y , u t a h 8 4 1 0 1 8 0 1 5 3 2 4 4 2 2 sheet: title: revisions : p r o j e c t # : 18.0405 d a t e : April 18, 2019 UNLESS A PROFESSIONAL SEAL WITH SIGNATURE AND DATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND IS NOT INTENDED FOR CONSTRUCTION, RECORDING PURPOSES, OR IMPLEMENTATION THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS & MODELS THEREOF, ARE PROPRIETARY & CAN NOT BE COPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED IN WHOLE OR IN PART WITHOUT THE SOLE AND EXPRESS WRITTEN PERMISSION FROM METHOD STUDIO INC. project: E D C B A E D C B A 1 2 3 4 5 6 1 2 3 4 5 6 USU EASTERN CAPITAL IMPROVEMENTS SITE LIGHTING 4/18/2019 CONSTRUCTION DOCUMENTS LAST SAVED: 18 Apr 19 LAST SAVE 4/18/2019 T:\JOBS\2018082 USU EASTERN MISCELLANEOUS\01 DRAWINGS\05 ELECTRICAL\SINE SOURCE PROJECT\SHEETS\EE001 ABBREVIATIONS, G.P.N., LEGEND & SHEET INDEX.DWG EE001 ABBREVIATIONS, G.P.N., LEGEND & SHEET INDEX SHEET INDEX # Sheet Title EE001 ABBREVIATIONS, G.P.N., LEGEND & SHEET INDEX ES101 ELECTRICAL SITE PLAN ES102 ELECTRICAL SITE PLAN ES501 ELECTRICAL SITE DETAILS ES601 LIGHTING SCHEDULE & ELEVATION BID SET

ES601 LIGHTING SCHEDULE & ELEVATION - gramoll.comgramoll.com/wp-content/uploads/2019/07/SITE_LIGHTING_Drawings_Updated... · emergency electrical metallic tubing end of line resistor

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ES601 LIGHTING SCHEDULE & ELEVATION - gramoll.comgramoll.com/wp-content/uploads/2019/07/SITE_LIGHTING_Drawings_Updated... · emergency electrical metallic tubing end of line resistor

ELECTRICAL ABBREVIATIONSAAFAFFAFGAFIAICALARCHASAWGBLDGBKBDCCABCATC/BCKTCLGCOCOMMCONNCUDEMODISCDNDWGEAELECELEVEMER, EMEMTEOLREQUIPEX, EXISTFBOFCUFFFIXTFLEXFLUORFTGFIGNDHPHVACIGIMCINISCJB, J-BOXKCMILKVAKW

AMPEREAMP FUSEABOVE FINISHED FLOORABOVE FINISHED GRADEARC-FAULT CIRCUIT-INTERRUPTERAMPERE INTERRUPTING CAPACITYALUMINUMARCHITECT(URAL)AMP SWITCHAMERICAN WIRE GAUGEBUILDINGBACKBOARDCONDUITCABINETCATALOG/CATEGORYCIRCUIT BREAKERCIRCUITCEILINGCONDUIT ONLYCOMMUNICATIONCONNECTIONCOPPERDEMOLITION/DEMOLISHDISCONNECTDOWNDRAWINGEACHELECTRICALELEVATOREMERGENCYELECTRICAL METALLIC TUBINGEND OF LINE RESISTOREQUIPMENTEXISTINGFURNISHED BY OTHERSFAN COIL UNITFINISHED FLOORFIXTUREFLEXIBLE METALLIC CONDUIT (STEEL)FLUORESCENTFEET OR FOOTGROUND FAULT INTERRUPTERGROUNDHORSEPOWERHEATING, VENTILATING & AIR CONDITIONINGISOLATED GROUNDINTERMEDIATE METAL CONDUITINCH(ES)SHORT CIRCUIT AMPERES, KAJUNCTION BOXTHOUSAND CIRCULAR MILSKILOVOLT AMPEREKILOWATT

LTGMAXMCBMECHMFRMINMLOMTDNECNECANEMANEUTNFCNCNICNLNONTSOCPPPHPNLPWRQTYRECEPREQ'DRGSCRMSCHEDSECTSPSNSPECSWSWBDSWGRSYSTEMPTELEXFMRT-STATTWPTWSPTYPUBCULUMCUNOVVAWW/WGWP

LIGHTINGMAXIMUMMAIN CIRCUIT BREAKERMECHANICALMANUFACTURERMINIMUMMAIN LUGS ONLYMOUNTEDNATIONAL ELECTRICAL CODENATIONAL ELECTRICAL CONTRACTOR'S ASSOCIATIONNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEUTRALNATIONAL FIRE CODENORMALLY CLOSEDNOT IN CONTRACTNIGHT LITENORMALLY OPENNOT TO SCALEOVERCURRENT PROTECTIONPOLEPHASEPANELPOWERQUANTITYRECEPTACLEREQUIREDRIGID GALVANIZED STEEL CONDUITROOMSCHEDULESECTIONSINGLE POLESOLID NEUTRALSPECIFICATIONSWITCHSWITCHBOARDSWITCH GEARSYSTEMTEMPORARYTELEPHONETRANSFORMERTHERMOSTATTWISTED PAIRTWISTED SHEILDED PAIRTYPICALUNIFORM BUILDING CODEUNDERWRITERS LABORATORYUNIFORM MECHANICAL CODEUNLESS NOTED OTHERWISEVOLT OR VOLTAGEVOLT AMPEREWATTWITHWIRE GUARDUL LISTED WEATHERPROOF, NEMA 3R or 4

S

P

3

4

X

3ØUP

3ØUS

UT

UTV

SITE ELECTRICAL

"x" POLE SWITCH - ARC FAULT INTERRUPTER

WALL MOUNT FIXTURE

THREE WAY SWITCH

FOUR WAY SWITCH

WALL MOUNT OCCUPANCY SENSOR: ADAPTIVE TECHNOLOGY

OCCUPANCY SENSOR

PHOTOCELL

QUANTITY OF CONDUCTORS: SHORT LINES = PHASE /SWITCH,LONG LINES = NEUTRAL

HOME-RUN

DISTRIBUTION PANEL

PANELBOARD

3-PHASE UNDERGROUND PRIMARY POWER

3-PHASE UNDERGROUND SECONDARY POWER

UNDERGROUND TELEPHONE

UNDERGROUND TV

POINT OF DISCONNECTION

POINT OF CONNECTION

OT OVERHEAD TELEPHONE

1ØOP 1-PHASE OVERHEAD PRIMARY POWER

DIMMER SWITCH: INCANDESCENT; 1000 W MINIMUM

F DIMMER SWITCH: FLUORESCENT; 100 W MINIMUM

P PILOT LIGHT SWITCH

POLE LIGHT; ONE HEAD

POLE LIGHT; TWO HEAD

DECORATIVE POLE LIGHT

TIME CLOCK

POWER AND DISTRIBUTION

LIGHTING FIXTURES

LIGHTING CONTROL

BRANCH CIRCUITING

ELECTRICAL LEGEND

SINGLE POLE SWITCH; "x" INDICATES SWITCH GROUP

X

OTV OVERHEAD TV

METER / METER SOCKET

S OCCUPANCY SENSOR: DUAL TECHNOLOGY

S OCCUPANCY SENSOR: PASSIVE INFRARED

S OCCUPANCY SENSOR: ULTRASONIC

DT

PR

US

1ØUP

1ØUS

1-PHASE UNDERGROUND PRIMARY POWER

1-PHASE UNDERGROUND SECONDARY POWER

UTILITY POLE

PUSH BUTTON

L DIMMER SWITCH: LED; 600 W MINIMUM

S OCCUPANCY SENSOR: # INDICATES WATTSTOPPER CAT# FORCOVERAGE PATTERN OR EQUIVALENT AS SPECIFIED

#

DETAIL CALL-OUT; TOP "X" REFERS TO DETAIL NUMBER & BOTTOM"XXX" REFERS TO SHEET NUMBER

ANNOTATIONS

XXXX

3ØOP

3ØOS

3-PHASE OVERHEAD PRIMARY POWER

3-PHASE OVERHEAD SECONDARY POWER

(E)3ØOP 3-PHASE OVERHEAD PRIMARY POWER : EXISTING

3-PHASE UNDERGROUND PRIMARY POWER : EXISTING(E)3ØUP

(E)UT UNDERGROUND TELEPHONE : EXISTING

DL SWITCH: DAYLIGHT ZONE AS DETAILED

2P SWITCH: SINGLE-THROW; DOUBLE-POLE

LSX/SYDIGITAL LIGHTING CONTROL SWITCH; SX = SWITCH CONTROLTYPE #1; SY = SWITCH CONTROL TYPE #2; ETC.

P PHOTOCELL: INTEGRATED TO LIGHTING CONTROL SYSTEM;P# = LIGHTING CONTROL TYPEP#

S OCCUPANCY SENSOR: LIGHTING CONTROL SYSTEM; O# =LIGHTING CONTROL TYPELO#

S OCCUPANCY SENSOR: HIGH BAYHB

3-PHASE UNDERGROUND PRIMARY POWER: DEMO

3-PHASE UNDERGROUND SECONDARY POWER: DEMO

(D)3ØUP

(D)3ØUS

3-PHASE UNDERGROUND SECONDARY POWER : EXISTING(E)3ØUS

(D)UT UNDERGROUND TELEPHONE : DEMO

(D)UTV UNDERGROUND TV : DEMO

(E)UTV UNDERGROUND TV : EXISTING

P PHOTOCELL: DAYLIGHT RESPONSIVE FOR CONTINUOUS DIMMINGAPPLICATIONS.DR

1ØUF 1-PHASE UNDERGROUND FEEDER

DIMMER SWITCH WITH WALL MOUNT OCCUPANCY SENSOR: ADAPTIVETECHNOLOGY

# KEYED NOTE CALLOUT

EQUIPMENT CALLOUT

K SWITCH: KEYED

PRODUCTION EQUIPMENT CALLOUT

#-#

#-#

WALL MOUNT OCCUPANCY SENSOR: VACANCY SENSOR FUNCTION

S OCCUPANCY SENSOR: VACANCY SENSOR FUNCTIONVS

WALL MOUNT OCCUPANCY SENSOR: OCCUPANCY SENSORFUNCTION

S OCCUPANCY SENSOR: OCCUPANCY SENSOR FUNCTIONOS

VS

OS

1ØOS 1-PHASE OVERHEAD SECONDARY POWER

3ØOT 3-PHASE OVERHEAD TRANSMISSION LINES

GENERAL PROJECT NOTES1. ALL ELECTRICAL INSTALLATIONS TO CONFORM TO THE LATEST NEC AND LOCAL CODES.

2. ELECTRICAL CONTRACTOR'S PROJECT MANAGER AND ON-SITE PROJECT FOREMAN SHALL REVIEWVENDOR SUBMITTALS FOR ACCURACY PRIOR TO SUBMITTING TO ENGINEER. INACCURACIES SHALL BECORRECTED PRIOR TO ENGINEER SUBMITTAL.

3. SUBMITTALS FOR EACH SYSTEM WILL BE REVIEWED BY ENGINEER UP TO TWO TIMES--ONE FULLSUBMITTAL FOR OVERALL COMPLIANCE AND ONE RESUBMITTAL. ADDITIONAL REVIEWS WILL BECHARGED TO CONTRACTOR AT ENGINEER'S STANDARD BILLING RATE.

4. SUBMITTALS TO ENGINEER SHALL INCLUDE ALL SPECIFIED SYSTEMS IN FIRST SUBMITTAL. PARTIALSUBMITTALS WILL BE RETURNED TO CONTRACTOR AS INCOMPLETE AND WILL BE CONSIDERED ONE OFTWO INCLUDED SUBMITTAL REVIEWS.

5. THE CLARITY OF RECORD DRAWING CHANGES MADE BY THE CONTRACTOR SHALL BE EQUAL TO THEORIGINAL DRAWINGS AS JUDGED BY THE ARCHITECT OR THE RECORD SET WILL BE RETURNED TO THECONTRACTOR FOR CLARIFICATION.

6. WHEN THE GENERAL CONTRACT CALLS FOR “RECORD” OR “AS-BUILT” DRAWINGS TO BE FURNISHED BYTHE CONTRACTOR AT JOB COMPLETION, THE ELECTRICAL CONTRACTOR SHALL BE REQUIRED TOFURNISH A COMPLETE SET OF “BLUE-PRINT READY” AUTOCAD ELECTRICAL DRAWINGS FOR ALLCONTRACTOR GENERATED CHANGES FROM THE DRAWINGS OF A CLARITY EQUAL TO THE ORIGINALDRAWINGS AS JUDGED BY THE ENGINEER. CONTACT ARCHITECT FOR DISKS OR REPRODUCIBLEORIGINAL MEDIA. PROVIDE DRAWINGS ON CD IN AUTOCAD FORMAT.

7. DO NOT SCALE ELECTRICAL FLOOR OR SITE PLANS. SEE ARCHITECTURAL DRAWINGS FOR ACCURATEBUILDING DIMENSIONS AND FIELD VERIFY ALL EXTERIOR DIMENSIONS.

8. ELECTRICAL DEVICES CANNOT BE SHOWN TO SCALE AND SOMETIMES OVERLAP BUILDING AND SITEELEMENTS. REFER TO ARCHITECTURAL ELEVATIONS FOR ACCURATE MOUNTING LOCATIONS

9. EMT IS NOT ALLOWED OUT OF DOORS.

10. DO NOT INSTALL IN-GRADE JUCTION BOXES UNLESS SPECIFICALLY SHOWN ON DRAWINGS.CONDUCTORS SHALL BE RUN CONTINOUS WITHOUT SPLICING FROM SOURCE OR DEVICE TO NEXTDEVICE.

11. CIRCUIT WIRE SIZES MUST MATCH BRANCH CIRCUIT BREAKERS PER NEC. VERIFY WITH PANELSCHEDULES BEFORE PULLING WIRE.

12. HOME RUNS MUST BE RUN EXACTLY AS SHOWN ON PLANS UNLESS OTHERWISE NOTED. DO NOTCOMBINE HOME RUNS INTO ONE CONDUIT THAT ARE NOT SHOWN COMBINED ON THE DRAWINGS.

13. THE ELECTRICAL CONTRACTOR SHALL RUN BRANCH CIRCUIT CONDUITS IN ATTIC SPACES IN A NEAT ANDWORKMANLIKE MANNER SO AS TO CONSERVE OPEN SPACES AS MUCH AS POSSIBLE. HVAC DUCTWORKAND PLUMBING SHALL HAVE LOCATION PRIORITY OVER BRANCH CIRCUIT CONDUIT RUNS.

14. CIRCUIT WIRING SHALL BE INSTALLED AS SHOWN ON THE DRAWINGS. ANY DEVIATIONS SHALL BEINITIATED BY A CHANGE ORDER FROM THE ARCHITECT. OTHERWISE THE RECORD SET SHALL MATCHTHE CONSTRUCTION SET.

15. PROVIDE AN EQUIPMENT GROUNDING CONDUCTOR, PULLED INTO THE CONDUIT WITH THE PHASECONDUCTOR, IN ALL SERVICE, FEEDER, AND BRANCH CIRCUITS.

16. PROVIDE A NEUTRAL CONDUCTOR FOR EACH BREAKER TRIP HANDLE. NEUTRALS SHALL NOT BE SHAREDBETWEEN BRANCH CIRCUITS.

17. ALL SITE LIGHTING CIRCUITS TO BE MINIMUM #12 CU IN MINIMUM 3/4” CONDUIT UNLESS OTHERWISENOTED.

18. MC CABLE IS NOT AN APPROVED ALTERNATE TO CONDUCTORS IN CONDUIT.

19. DO NOT INSTALL MORE THAN THREE PHASE CONDUCTORS IN ANY HOME-RUN CONDUITS UNLESSSPECIFICALLY INDICATED ON DRAWINGS.

20. INCLUDE AS PART OF THE JOB THE INSTALLATION OF AN EXTRA 200 FT OF 3/4” EMT WITH 4 #10 WIRESINSTALLED AND TWO J-BOX TERMINATIONS.

21. REMOVE ALL OLD AND/OR UNUSED EXISTING CONDUIT AND ELECTRICAL APPARATUS FROM EXTERIOR ORINTERIOR EXPOSED SURFACES.

22. WHERE EXISTING ELECTRICAL EQUIPMENT IS TO REMAIN BUT THE SURFACE THAT IT IS MOUNTED ON ISTO BE REWORKED UNDER OTHER CONTRACTS, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLETO REMOVE AND INSTALL OR MODIFY THE EXISTING EQUIPMENT AS REQUIRED TO MEET THE DESIGNINTENT. SEE ARCHITECTURAL DRAWINGS FOR ROOF, CEILINGS, WALLS, SOFFITS, FLOORS, ETC.

23. REMOVE ALL UNUSED CONDUITS AND CIRCUITS IN THE DEMOLTIONED AREA AS THEY ARE IDENTIFIED ASUNUSED OR ABANDONED.

24. REMOVE ALL EXISTING ELECTRICAL DEVICES, EQUIPMENT, AND APPARATUS AS THEY ARE IDENTIFIED ASUNUSED OR ABANDONED.

25. RELOCATE EXISTING CONDUITS AND CIRCUITS AS REQUIRED THAT ARE PRESENTLY SERVINGEQUIPMENT THAT IS INTENDED TO REMAIN IN SERVICE BUT SAID CONDUITS ARE CURRENTLY RUNNINGTHROUGH AREAS TO BE DEMOLITIONED.

26. WHERE EXISTING CONDUIT RUNS ARE RE-USED BY SPECIAL PERMISSION FROM THE ARCHITECT, ASEPARATE GREEN, INSULATED GROUND WIRE SHALL BE PULLED IN THE CONDUIT AND BONDED AT EACHEND AS REQUIRED.

27. ALL PATCH, REPAIR, REPAINT AND COVER UP REQUIRED AS A RESULT OF ELECTRICAL REMODEL IS TO BETHE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, BUT ACTUAL WORK IS TO BE PERFORMED BYQUALIFIED PERSONNEL.

28. FIELD VERIFY CONDITIONS FOR NEW WIRING. SURFACE RACEWAYS MUST RECEIVE PRIOR APPROVALFROM THE ARCHITECT BEFORE BID AND MUST BE PAINTED TO MATCH THE SURFACE ON WHICH THEYARE MOUNTED.

29. PROVIDE NEUTRAL CONNECTION TO 208/240/480V, SINGLE-PHASE EQUIPMENT. RUN SEPARATE GROUNDWIRE TO ALL OUTDOOR UNITS AND BOND TO THE EQUIPMENT GROUND LUG.

30. REVIEW THE STATE DESIGN REQUIREMENTS MANUAL PRIOR TO BID.

31. REVIEW THE USU A&E DESIGN MANUAL PRIOR TO BID.

32. WHERE THERE ARE CONFLICTS IN THE DRAWINGS AND/OR SPECIFICATIONS THE CONTRACTOR SHALLNOTIFY THE ARCHITECT/ENGINEER PRIOR TO BID. WHERE NO NOTIFICATION IS GIVEN THE MORESTRINGENT INTERPRETATION (GENERALLY INTERPRETED TO BE THE MORE COSTLY) WILL BE ENFORCED.

3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2

sheet:

title:

revisions :

p r o j e c t # : 18.0405

d a t e : April 18, 2019

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND ISNOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDINGALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &MODELS THEREOF, ARE PROPRIETARY & CAN NOT BECOPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED INWHOLE OR IN PART WITHOUT THE SOLE AND EXPRESSWRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

USU EASTERNCAPITALIMPROVEMENTSSITE LIGHTING

4/18/2019

CONSTRUCTIONDOCUMENTS

LAS

T S

AV

ED

: 18

Apr

19

LAS

T S

AV

E 4

/18/

2019

T:\J

OB

S\2

0180

82 U

SU

EA

STE

RN

MIS

CE

LLA

NE

OU

S\0

1 D

RA

WIN

GS

\05

ELE

CTR

ICA

L\S

INE

SO

UR

CE

PR

OJE

CT\

SH

EE

TS\E

E00

1 A

BB

RE

VIA

TIO

NS

, G.P

.N.,

LEG

EN

D &

SH

EE

T IN

DE

X.D

WG

EE001

ABBREVIATIONS,G.P.N., LEGEND& SHEET INDEX

SHEET INDEX# Sheet Title

EE001 ABBREVIATIONS, G.P.N., LEGEND & SHEET INDEXES101 ELECTRICAL SITE PLANES102 ELECTRICAL SITE PLANES501 ELECTRICAL SITE DETAILSES601 LIGHTING SCHEDULE & ELEVATION

BID SET

Page 2: ES601 LIGHTING SCHEDULE & ELEVATION - gramoll.comgramoll.com/wp-content/uploads/2019/07/SITE_LIGHTING_Drawings_Updated... · emergency electrical metallic tubing end of line resistor

BLE

AC

HE

RS

WM

400 NORTH STREET

500 E

AST

STRE

ET

600 NORTH STREET

300 E

AST

STRE

ET

BDAC

COLLEGE CENTER

WORKFORCESERVICES

FACILITIESMAINTENANCE

ARMORY

ATHLETIC FIELD WITHTRACK

DORMITORY

CAREERCENTER

PARKING

PURCHASE &RECEIVING

SUBSTATION

SERVICEYARD

SERVICEYARD CAREER

CENTERSTORAGE

G.J. REEVESBUILDING

TRANSTRANS

SESSIONSHALL

elec

elec

elecvoltage

Storm Drain

B BB B

B

switchhigh

STEAM HEAT TUNNEL

LP

unde

rgrou

nd po

wer

GEARYTHEATER

LIBRARY

LDS CHURCH

LP

B B B B

B

B

B

B

B

B

B

HEATPLANT

402

403

405

407

408

409

410

411

413

414415

416

417

420 421 422

B

B

B

BLEA

CHER

S

"TP""TL"

GEARY THEATER

ART BUILDING

MH

MH

MH

BBB

B

BB

BB

30'

30'

30'

30'

3' BASE

3' BASE

3' BASE

30'

F

FF F

F

F

FFF

F

FF

F

F

F

F

B1

FFF

F

F

F

F

F F F

F

F

B1B1

F

F

B1

B

A

B

A

BABA

B

A

B

A

A

B

15'

EX. PNL

SWTICH

RAB

RAB

GB RAB RAB RAB

RAB

GB

GB

P4-L7K(B1)1

P5-L7K(B1)1

4

P5-L7K(B1)1

4

P5-L7K(B1)1

4

P5-L

7K(B

1)1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

P5-L

7K(B

1)

1

F

4

1

P5-L7K(B1F)

1

P5-L7K(B1F)

41

P4-L7K(B1F)

4 1

P4-L7K(B1F)

4 1

P4-L7K(B1F)

4 1

P5-L7K(B1F)

4

2

P5-L7K(B1)1

P5-L7K(B1)3

6 7

9

P3-L7K

14

P5-L7K

14

4 4

1P3-L7S

41

P3-L7S

41

P3-L7S

41

P3-L7S

41

P3-L7S

41

P3-L9K

4

14

P5-L9L

14

P5-L9L

14

P5-L9L

14

P4-L7K

14

P3-L7K

14

P3-L7K

14

P3-L7K

14

P2-L7K

1. REPLACE EXISTING POLE WITH NEW OF TYPE INDICATED.

2. REMOVE EXISTING POLE AND CONCRETE BASE.

3. PROVIDE NEW POLE AND CONCRETE BASE.

4. PROVIDE ADAPTER PLATE FOR NEW POLE MOUNTING ON EXISTING BOLT PATTERN. SEEDETAIL B/ES501.

5. PROVIDE 12"x18" FLUSH-MOUNTED PULL-BOX, WITH LIGHTING LOGO COVER, IN LOCATIONOF REMOVED POLE AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY.

6. CONNECT TO EXISTING LIGHTING CONTROL INDICATED.

7. CONNECT TO EXISTING CIRCUIT INDICATED.

8. EXTEND CIRCUIT SERVING REMOVED POLE TO NEW LOCATION INDICATED. RE-PULLCONDUCTORS COMPLETE FROM NEAREST POLE ON CIRCUIT.

9. TUNNEL UNDER OR REMOVE AND REPLACE SECTIONS OF EXISTING CONCRETE FOR NEWCIRCUIT INSTALLATION. SEE GENERAL NOTE #8 BELOW FOR CONCRETE REPLACEMENTREQUIREMENTS.

10. PATH OF WATER LINE UPGRADE. COORDINATE EXISTING POLE REMOVAL WITH WORKBEING DONE UNDER SEPARATE CONTRACT.

11. REMOVE AND REINSTALL POLE AND BASE TO ALLOW FOR CHILLED WATER UPGRADESUNDER SEPARATE PROJECT.

12. REMOVE POLES TO PREVENT DAMAGE BY EXCAVATION EQUIPMENT FOR CHILLED WATERUPGRADES UNDER SEPARATE PROJECT. PROTECT CIRCUITS AND BASES AS REQUIRED.RE-INSTALL POLES UPON PROJECT COMPLETION.

13. REPLACE EXISTING WALL MOUNT FIXTURE WITH NEW IN SAME LOCATION.

14. PROVIDE LINE ITEM PRICING FOR WORK ASSOCIATED WITH CHILLED WATER UPGRADEPRICING.

15. REPAIR ASPHALT AND CONCRETE SURFACES WHERE POLE BASE WAS REMOVED FROMHARDSCAPE.

16. PROVIDE LINE ITEM PRICING FOR EACH AREA INDICATED AREAS ARE NUMBERED INORDER OF PRIORITY.

SHEET KEYED NOTES

1. DEMOLITION PLAN IS ENGINEER'S ATTEMPT TO ASSIST BIDDERS IN ESTIMATING REMOVALCOSTS OF EXISTING EQUIPMENT. PLAN IS NOT INTENDED TO BE ALL-INCLUSIVE, AND IT ISTHE BIDDERS RESPONSIBILITY TO VERIFY ALL EXISTING EQUIPMENT AND DEVICES TO BEREMOVED PRIOR TO BIDDING.

2. EXISTING ITEMS TO BE REMOVED ARE INDICATED AS BOLD/DASHED. ITEMS TO REMAINARE SHOWN AS LIGHT/SOLID.

3. MAINTAIN CIRCUIT CONTINUITY FOR DEVICES DOWNSTREAM OF ITEMS TO BE REMOVED.

4. CIRCUIT ROUTING IS SCHEMATIC UNLESS OTHERWISE NOTED.

5. NEW WALKWAY POLE BASES TO BE INSTALLED PER DETAIL A/ES501 UNLESS OTHERWISEINDICATED.

6. SITE LIGHTING CIRCUITS TO BE MINIMUM #6 CU IN 1" MINIMUM CONDUIT UNLESSOTHERWISE INDICATED.

7. CONTRACTOR MAY OPT TO REPLACE SECTIONS OF CONCRETE INSTEAD OF TUNNELINGUNDER EXISTING CONCRETE WHERE NOTED.

8. REMOVE, AND REPLACE WITH NEW, ENTIRE SECTIONS OF CONCRETE SURFACESCOMPLETE TO COLD JOINTS FOR NEW ELECTRICAL INSTALLATIONS. ONLY REMOVESECTIONS WHERE REQUIRED TO INSTALL NEW CIRCUITING.

9. CUT, PATCH AND REPAIR EXISTING SURFACES AS NEEDED FOR NEW CIRCUITINSTALLATIONS. INCLUDE ALL LANDSCAPING AND FLATWORK RESTORATION COSTS ASNEEDED TO REPAIR SURFACES DAMAGED BY CONSTRUCTION.

10. PROTECT EXISTING TREE ROOTS ALONG CIRCUIT PATHS. HAND DIG AS REQUIRED.

11. CONTRACTOR SHALL VERIFY THE VOLTAGE AT ALL FIXTURE LOCATIONS PRIOR TOORDERING FIXTURES. EXISTING VOLTAGES ARE BELIEVED TO BE 208V, 1ɸ, 3W.

12. LEGALLY DISPOSE OF REMOVED FIXTURES & POLES UNLESS OTHERWISE DIRECTED BYOWNER.

13. EXISTING POLE BASE BOLT CIRCLES ARE A MIX OF APPROXIMATELY 8" DIAMETER, 4-BOLTIN CIRCULAR PATTERN AND 8", 3-BOLT IN TRIANGULAR PATTERN. ADAPTER PLATES HAVEBEEN NOTED TO BE PROVIDED FOR ALL 3-BOLT BASES. PROVIDE ADAPTER PLATES FORALL 4-BOLT BASES TO REMAIN OR ARRANGE WITH FIXTURE MANUFACTURER FOR NEWPOLE BOLT PATTERNS TO MATCH EXISTING BOLTS. INCLUDE A MINIMUM OF 20% OF QUADBOLT POLES TO BE USED AT OWNER/ENGINEER DISCRETION TO RE-CENTER POLES.

14. NOTIFY ENGINEER OF ANY POLE BASES LESS THAN 16" DIAMETER SHOWN TO REMAIN.

15. RESTORE ALL IRRIGATION SYSTEM COMPONENTS DAMAGED BY CONSTRUCTION.

16. CONTRACTOR SHALL COORDINATE POLE OPTICAL ORIENTATION WITH ENGINEER PRIORTO POLE BASE INSTALLATION FOR ALL P2, P3 AND/OR P4 SERIES POLES.

17. PROVIDE GRASS/HARDSCAPE TRANSITIONS PER DETAILS D/ES501 AND E/ES501 WHENPOLES ARE LOCATED ADJACENT TO HARDSCAPE.

18. BACKFILL HOLES OF ALL REMOVED POLE BASES WITH COMPACTED STRUCTURAL FILL TOWITHIN 6" OF GRADE. FILL FROM STRUCTURAL BACKFILL TO GRADE WITH HARDSCAPE ORLANDSCAPE MATCHING ADJACENT AREAS.

GENERAL SHEET NOTES

2P4-L1L3

222

P4-L1L3

P4-L1L3

P4-L1L3

1P5-L9K

4

1P5-L9K

4

1P5-L9K

4

1P5-L9K

4

P3-L7K(H)31

4

P4-L7K

P4-L7K(H)

14

P3-L7K

14

P3-L7K(H) P4-L7K(H)

14

14

P5-L9L

14

P5-L9L

14

P4-L7K

14

P4-L7K

14

P4-L7K

25

14

P3-L7K

3P4-L7K

25

1P4-L7K

4

1P3-L7K

4

25

25

2 2P4-L12

33

3P5-L7K

3P5-L7K 3 P5-L7K

3P3-L7K

2P4-L12

3

2

P4-L1232

3 P2-L7KP2-L7K1

4

P4-L7K1

4

P2-L7K(H)2 3

P2-L3K(H)1

4

P4-L9K1

4

P2-L3K(H)1

4

P4-L9K(H)1

4

P2-L3K(H)1

4

P4-L9K(H)1

4

P4-L9K(H)1

4

P2-L3K(H)1

4

P2-L3K(H)1

4

P3-L7K

14

P3-L7K(H)

3

P3-L7K(H)

322

P3-L7K

14

P3-L7K

32

8 8 8 8

14

14

14

P4-L7K

P4-L7K

P5-L7K

P4-L12

67

9

9

5

67

8

14

P4-L

9K

P4-L7K(H)

P4-L7K(H)

14

215

215

24

67

14

P4-L9L

2

10

AB

12

12

AB

1114

1214

1214

1214

1114

3P4-L12

6

13

13

ES6011

PANEL "A"

PANEL "K"

PANEL "C"PANEL "D"PANEL "F"

PANEL "Q"PANEL "G"

PANEL "H"

PANEL "J"PANEL "S"

PANEL "B"

OW3-L10

OW3-L10

14

5

5

7

116

216

516

616

9

8

3164

16

CHILLED WATERPROJECT

Scale: 1"=50'-0"1

N

W E

ELECTRICAL SITE PLAN

3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2

sheet:

title:

revisions :

p r o j e c t # : 18.0405

d a t e : April 18, 2019

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND ISNOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDINGALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &MODELS THEREOF, ARE PROPRIETARY & CAN NOT BECOPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED INWHOLE OR IN PART WITHOUT THE SOLE AND EXPRESSWRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

USU EASTERNCAPITALIMPROVEMENTSSITE LIGHTING

6/28/2019

CONSTRUCTIONDOCUMENTS

LAS

T S

AV

ED

: 28

Jun

19LA

ST

SA

VE

6/2

8/20

19 T

:\JO

BS

\201

8082

US

U E

AS

TER

N M

ISC

ELL

AN

EO

US

\01

DR

AW

ING

S\0

5 E

LEC

TRIC

AL\

SIN

E S

OU

RC

E P

RO

JEC

T\S

HE

ETS

\ES

101

ELE

CTR

ICA

L S

ITE

PLA

N.D

WG

BID ADDENDUM 06/28/20191

ES101

ELECTRICALSITE PLAN

1

1

AutoCAD SHX Text
a
AutoCAD SHX Text
b
AutoCAD SHX Text
c
AutoCAD SHX Text
3
AutoCAD SHX Text
d
AutoCAD SHX Text
3
AutoCAD SHX Text
d
AutoCAD SHX Text
3
AutoCAD SHX Text
h
AutoCAD SHX Text
g
AutoCAD SHX Text
MH
AutoCAD SHX Text
GM
AutoCAD SHX Text
MH
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
D
AutoCAD SHX Text
P
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
H
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
U
AutoCAD SHX Text
SHANE D.
AutoCAD SHX Text
SWENSON
AutoCAD SHX Text
No.
AutoCAD SHX Text
294174
Page 3: ES601 LIGHTING SCHEDULE & ELEVATION - gramoll.comgramoll.com/wp-content/uploads/2019/07/SITE_LIGHTING_Drawings_Updated... · emergency electrical metallic tubing end of line resistor

400 NORTH STREET

500 NORTH STREET

600 NORTH STREET

300 E

AST

STRE

ET

200 E

AST

STRE

ET

PARKING

NURSING HOME

TUCKERHALL

PRICE CITY SWIMMINGPOOL

COMPUTER BUSINESS

PARKING

TENNIS COURTS

PURREC

S

BURTENSHAWHALL

412

418419

MH

MH

15'20'15'

20'

BROKEN GLASS

WP

WP

1. REPLACE EXISTING POLE WITH NEW OF TYPE INDICATED.

2. REMOVE EXISTING POLE AND CONCRETE BASE.

3. PROVIDE NEW POLE AND CONCRETE BASE.

4. PROVIDE ADAPTER PLATE FOR NEW POLE MOUNTING ON EXISTING BOLT PATTERN. SEEDETAIL B/ES501.

5. PROVIDE 12"x18" FLUSH-MOUNTED PULL-BOX WITH LIGHTING LOGO COVER IN LOCATIONOF REMOVED POLE FOR LOCATIONS AS REQUIRED TO MAINTAIN CIRCUIT CONTINUITY.

6. CONNECT TO EXISTING LIGHTING CONTROL INDICATED.

7. CONNECT TO EXISTING CIRCUIT INDICATED.

8. EXTEND CIRCUIT SERVING REMOVED POLE TO NEW LOCATION INDICATED. RE-PULLCONDUCTORS COMPLETE FROM NEAREST POLE ON CIRCUIT.

9. TUNNEL UNDER OR REMOVE AND REPLACE SECTIONS OF EXISTING CONCRETE ORASPHALT FOR NEW CIRCUIT INSTALLATION. SEE GENERAL NOTE #9 BELOW FORCONCRETE REPLACEMENT REQUIREMENTS.

10. REPLACE EXISTING WALL MOUNT FIXTURE WITH NEW IN SAME LOCATION.

11. PROVIDE LINE ITEM PRICING FOR EACH AREA INDICATED AREAS ARE NUMBERED INORDER OF PRIORITY.

SHEET KEYED NOTES

1. DEMOLITION PLAN IS ENGINEER'S ATTEMPT TO ASSIST BIDDERS IN ESTIMATING REMOVALCOSTS OF EXISTING EQUIPMENT. PLAN IS NOT INTENDED TO BE ALL-INCLUSIVE, AND IT ISTHE BIDDERS RESPONSIBILITY TO VERIFY ALL EXISTING EQUIPMENT AND DEVICES TO BEREMOVED PRIOR TO BIDDING.

2. EXISTING ITEMS TO BE REMOVED ARE INDICATED AS BOLD/DASHED. ITEMS TO REMAINARE SHOWN AS LIGHT/SOLID.

3. MAINTAIN CIRCUIT CONTINUITY FOR DEVICES DOWNSTREAM OF ITEMS TO BE REMOVED.

4. CIRCUIT ROUTING IS SCHEMATIC UNLESS OTHERWISE NOTED.

5. NEW WALKWAY POLE BASES TO BE INSTALLED PER DETAIL A/ES501 UNLESS OTHERWISEINDICATED.

6. SITE LIGHTING CIRCUITS TO BE MINIMUM #6 CU IN 1" MINIMUM CONDUIT UNLESSOTHERWISE INDICATED.

7. CONTRACTOR MAY OPT TO REPLACE SECTIONS OF CONCRETE INSTEAD OF TUNNELINGUNDER EXISTING CONCRETE WHERE NOTED.

8. REMOVE, AND REPLACE WITH NEW, ENTIRE SECTIONS OF CONCRETE SURFACESCOMPLETE TO COLD JOINTS FOR NEW ELECTRICAL INSTALLATIONS. ONLY REMOVESECTIONS WHERE REQUIRED TO INSTALL NEW CIRCUITING.

9. CUT, PATCH AND REPAIR EXISTING SURFACES AS NEEDED FOR NEW CIRCUITINSTALLATIONS. INCLUDE ALL LANDSCAPING AND FLATWORK RESTORATION COSTS ASNEEDED TO REPAIR SURFACES DAMAGED BY CONSTRUCTION.

10. PROTECT EXISTING TREE ROOTS ALONG CIRCUIT PATHS. HAND DIG AS REQUIRED.

11. CONTRACTOR SHALL VERIFY THE VOLTAGE AT ALL FIXTURE LOCATIONS PRIOR TOORDERING FIXTURES. EXISTING VOLTAGES ARE BELIEVED TO BE 208V, 1ɸ, 3W.

12. LEGALLY DISPOSE OF REMOVED FIXTURES & POLES UNLESS OTHERWISE DIRECTED BYOWNER.

13. EXISTING POLE BASE BOLT CIRCLES ARE A MIX OF APPROXIMATELY 8" DIAMETER, 4-BOLTIN CIRCULAR PATTERN AND 8", 3-BOLT IN TRIANGULAR PATTERN. ADAPTER PLATES HAVEBEEN NOTED TO BE PROVIDED FOR ALL 3-BOLT BASES. PROVIDE ADAPTER PLATES FORALL 4-BOLT BASES TO REMAIN OR ARRANGE WITH FIXTURE MANUFACTURER FOR NEWPOLE BOLT PATTERNS TO MATCH EXISTING BOLTS. INCLUDE A MINIMUM OF 20% OF QUADBOLT POLES TO BE USED AT OWNER/ENGINEER DISCRETION TO RE-CENTER POLES.

14. NOTIFY ENGINEER OF ANY POLE BASES LESS THAN 16" DIAMETER SHOWN TO REMAIN.

15. RESTORE ALL IRRIGATION SYSTEM COMPONENTS DAMAGED BY CONSTRUCTION.

16. CONTRACTOR SHALL COORDINATE POLE OPTICAL ORIENTATION WITH ENGINEER PRIORTO POLE BASE INSTALLATION FOR ALL P2, P3 AND/OR P4 SERIES POLES.

17. PROVIDE GRASS/HARDSCAPE TRANSITIONS PER DETAILS D/ES501 AND E/ES501 WHENPOLES ARE LOCATED ADJACENT TO HARDSCAPE.

18. BACKFILL HOLES OF ALL REMOVED POLE BASES WITH COMPACTED STRUCTURAL FILL TOWITHIN 6" OF GRADE. FILL FROM STRUCTURAL BACKFILL TO GRADE WITH HARDSCAPE ORLANDSCAPE MATCHING ADJACENT AREAS.

GENERAL SHEET NOTES

2P5-L9K

33

P5-L9K2 2

P3-L9K

33P5-L9K

9

67 8

2,OW3-L6K10

22,OW3-L6K10

OW2-L6K10

OW2-L6K10

2,OW4-L6K10

2,OW4-L6K10

OW4-L6K10

OW4-L6K10

2

1P3-L7K

4

1P3-L7K

4

1P3-L7K

4

1P3-L7K

41

P4-L7K

4

1P5-L7K

4

1P4-L7K

4

1P5-L7K

4

1P5-L7K

4

2P5-L12

3

1P5-L12

4

2P5-L12

32

P5-L12

32P5-L12

3

2P5-L12

3 3P5-L12

9

67

1P3-L7K

4

1P3-L7K

4

1P3-L7K

4

1P3-L7K

4

4,OW4-L6K10

3,OW4-L6K10

OW3-L6K10

2,OW4-L6K10

1P4-L7K

4

1P4-L7K

41

P3-L7K

4

3P3-L7K

2

9

85

12,P5-L7K

4

5

711

Scale: 1"=50'-0"1

N

W E

ELECTRICAL SITE PLAN

3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2

sheet:

title:

revisions :

p r o j e c t # : 18.0405

d a t e : April 18, 2019

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND ISNOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDINGALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &MODELS THEREOF, ARE PROPRIETARY & CAN NOT BECOPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED INWHOLE OR IN PART WITHOUT THE SOLE AND EXPRESSWRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

USU EASTERNCAPITALIMPROVEMENTSSITE LIGHTING

6/28/2019

CONSTRUCTIONDOCUMENTS

LAS

T S

AV

ED

: 27

Jun

19LA

ST

SA

VE

6/2

7/20

19 T

:\JO

BS

\201

8082

US

U E

AS

TER

N M

ISC

ELL

AN

EO

US

\01

DR

AW

ING

S\0

5 E

LEC

TRIC

AL\

SIN

E S

OU

RC

E P

RO

JEC

T\S

HE

ETS

\ES

102

ELE

CTR

ICA

L S

ITE

PLA

N.D

WG

BID ADDENDUM 06/28/20191

ES102

ELECTRICALSITE PLAN

1

1

AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
D
AutoCAD SHX Text
P
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
O
AutoCAD SHX Text
N
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
H
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
U
AutoCAD SHX Text
SHANE D.
AutoCAD SHX Text
SWENSON
AutoCAD SHX Text
No.
AutoCAD SHX Text
294174
Page 4: ES601 LIGHTING SCHEDULE & ELEVATION - gramoll.comgramoll.com/wp-content/uploads/2019/07/SITE_LIGHTING_Drawings_Updated... · emergency electrical metallic tubing end of line resistor

1/2"(MINIMUM)x24" ANCHOR BOLTS2" BEND

1/2" ROUND ALL EDGES

CONCRETE BASE 3000 PSI. BASEINSTALLED BY PROFESSIONAL

CONCRETE TRADE UNDERELECTRICAL CONTRACT.

4 - #5 REBARWITH #2 TIES

2'-7" MIN.3'-0" MIN

4" BOLT PROJECTION

FRONTSIDE

SEE SITEPLAN FORWIRE SIZE

CONTINUOUS #8 CU

1" PVC MINIMUM1" GRC (MINIMUM)

A

24"

5" RAISE 5" MOW STRIP

GROUT UNDER BASE

(MIN

)

DECORATIVE BASE COVER

FIXTURE HEAD

5" DIAMETER 12' ALUMINUM POLE.

12'-0"

FLAG HOLDER(WHERE NOTED - "F" ACCESSORY)

REBAR CONNECTION

FINISH GRADE6" NATIVE SOIL(MIN)WITH LANDSCAPE TO MATCH EXISTING

SIDEWALK SIDEWALK

STEEL PLATE

NEW POLE PLATE(FACTORY WELDED TO POLE)

EXISTING CONCRETEPOLE BASE

EXISTINGPOLE BOLTS

(TYPICAL OF 4)

NEW POLE BOLTS(TYPICAL OF 4)

DETAIL NOTES1. CUT EXISTING BOLTS TO ALLOW NEW POLE PLATE TO SIT TIGHT TO NEW LEVELING NUTS.

2. PROVIDE SECURING NUTS TO FASTEN PLATE TO EXISTING POLE BASE.

3. PROVIDE 1/2" GALVANIZED STEEL ADAPTER PLATE. NEW PLATE SHALL BE FULLYCONCEALED BY BASE COVER.

4. CUT ROUNDED END OF NEW POLE BOLTS OR PROVIDE STRAIGHT BOLTS OF EQUIVALENTDIAMETER. DRILL AND EPOXY NEW BOLTS INTO EXISTING BASE.

5. PROVIDE NUTS TO SECURE NEW BOLTS TO ADAPTER PLATE (TYPICAL OF 4 LOCATIONS).

6. PROVIDE DOUBLE NUT ON NEW BOLTS BETWEEN ADAPTER PLATE AND NEW POLE PLATE.TOP NUT SHALL BE USED AS LEVELING NUT (TYPICAL OF 4 LOCATIONS).

7. PROVIDE UPPER NUTS ON NEW BOLTS PER MANUFACTURER RECOMMENDATIONS TOSECURE NEW POLE IN PLACE.

NEW POLE

4

1

3

DIMENSIONS:A = 48" FOR POLES 15'-0" OR LESSA = 72" FOR POLES TALLER THAN 15'-0"

(2)BREAK-AWAY, CLAMP-ONBANNER ARMS

(WHERE NOTED -"B1 ACCESSORY)

FLAG

GENERAL NOTES1. NEW ADAPTER PLATE SHALL BE CUT TO FIT BENEATH NEW POLE BASE COVER.

2. NOTIFY ENGINEER OF ANY POLE BASES LESS THAN 16" DIAMETER SHOWN TO REMAIN.

3. GROUT UNDER BASES AS SHOWN IN POLE BASE DETAILS.

4. ALLOW ADAPTER PLATE ADJUSTMENTS SO NEW POLES CENTER ON EXISTING BASES.

2

5

6

6"(M

AX)

3'-0" MIN12" MIN

STRUCTURAL FILL(ROAD BASE OR PIT RUN)

COMPACTED TO 95% MAXIMUMDENSITY

UNDISTURBEDEARTH

CONCRETE FORMS TANGENTTO SONOTUBE

MONOTHIC POUR

SONOTUBE DIAMETER(CUT TO BOTTOM OF SLAB)

SIDEWALK, CURB OR OTHERHARDSCAPE

5" RAISE

6" CONCRETE SLAB TANGENT TO BASE RADIUSAND SQUARE TO SIDEWALK

POLE BASE BOLT CIRCLE

SIDEWALK, CURB OR OTHERHARDSCAPE

5" RAISE

POLE BASE BOLT CIRCLE

MOW STRIP

SONOTUBE DIAMETER

CONCRETE FORMS TANGENT TO BASE RADIUSAND SQUARE TO SIDEWALK

SONOTUBE DIAMETER(CUT TO BOTTOM OF SLAB)

6" CONCRETE SLAB

12" MIN12" MIN

A POLE BASE DETAIL: SIDEWALKSCALE: NO SCALEB ADAPTER PLATE DETAIL

SCALE: NO SCALE

D POLE BASE GRASS/HARDSCAPE FINISH DETAIL: CORNER POLESCALE: NO SCALE

E POLE BASE GRASS/HARDSCAPE FINISH DETAIL: INTERIOR SECTIONSCALE: NO SCALE

TRANSPO 4100 COUPLING4 PER POLE, TYPICAL

N.T.S.

2-3/4

"

1"-8 UNC NUT PER ASTM A563 GRADE DH

1/8" X 1-1/8" X 1-1/8" X 2"FLAT WASHER PER ASTM F436

1/8" X 1-1/8" X 1- 1-1/8 X 2"FLAT WASHER PER ASTM F436

1" BREAKAWAY COUPLING

1/8" X 1-1/8" X 2"FLAT WASHER PER ASTM F436

GALVANIZED ANCHOR BOLT1"-8 UNC THREADS

1-1/2" (+/-) 1/8"

6-11

/16"

POLE BASE PLATE

UPPER WRENCH FLATS

TRANSPO 4075 COUPLING4 PER POLE, TYPICAL

GALVANIZED STEEL SHIM14g AND/OR 18g THICKNESS(IF NEEDED FOR LEVELING)

2 SHIMS MAXIMUM

TOP OF FOUNDATION

N.T.S.

3/4"-10 UNC NUT PER ASTM A563 GRADE DH

1/8" X 13/16" X 1-7/16"FLAT WASHER PER ASTM F436

3/4" BREAKAWAY COUPLING

1/8" X 13/16" X 1-7/16"FLAT WASHER PER ASTM F436

GALVANIZED ANCHOR BOLT3/4"-10 UNC THREADS

1-3/8" (+/-) 1/8"

1/8" X 13/16" x 1-7/16"FLAT WASHER PER ASTM F436

LOWER WRENCH FLATS

2-1/4

"5-

15/16

"

NOTES:3/4" OR 1" COUPLING PER POLE MANUFACTURER'SRECOMMENDED MOUNTING BOLT SIZE.

TRANSPO 4100 COUPLING4 PER POLE, TYPICAL

N.T.S.

2-3/4

"

1"-8 UNC NUT PER ASTM A563 GRADE DH

1/8" X 1-1/8" X 1-1/8" X 2"FLAT WASHER PER ASTM F436

1/8" X 1-1/8" X 1- 1-1/8 X 2"FLAT WASHER PER ASTM F436

1" BREAKAWAY COUPLING

1/8" X 1-1/8" X 2"FLAT WASHER PER ASTM F436

GALVANIZED ANCHOR BOLT1"-8 UNC THREADS

1-1/2" (+/-) 1/8"

6-11

/16"

POLE BASE PLATE

UPPER WRENCH FLATS

TRANSPO 4075 COUPLING4 PER POLE, TYPICAL

GALVANIZED STEEL SHIM14g AND/OR 18g THICKNESS(IF NEEDED FOR LEVELING)

2 SHIMS MAXIMUM

TOP OF FOUNDATION

N.T.S.

3/4"-10 UNC NUT PER ASTM A563 GRADE DH

1/8" X 13/16" X 1-7/16"FLAT WASHER PER ASTM F436

3/4" BREAKAWAY COUPLING

1/8" X 13/16" X 1-7/16"FLAT WASHER PER ASTM F436

GALVANIZED ANCHOR BOLT3/4"-10 UNC THREADS

1-3/8" (+/-) 1/8"

1/8" X 13/16" x 1-7/16"FLAT WASHER PER ASTM F436

LOWER WRENCH FLATS

2-1/4

"5-

15/16

"

NOTES:3/4" OR 1" COUPLING PER POLE MANUFACTURER'SRECOMMENDED MOUNTING BOLT SIZE.

BOLT COVER

SQUARE POLE(SEE FIXTURE SCHEDULE)

HAND HOLE COVER

1" X 36" X 4" HOOKANCHOR BOLT

GROUT UNDER BASE

FRONT

2'-0" MIN

SIDE

2'-0" MIN 3'-0" MIN.

5'-0"

FINISH GRADE

1" GRC (MINIMUM)1" PVC (MINIMUM)

SEE SITE PLANFOR WIRE SIZE

4 - #5 REBARWITH #2 TIES

CONTINUOUS #8 CU1/2" ROUND ALL EDGES

REBAR CONNECTION

CONCRETE BASE 3000 PSI INUNDISTURBED EARTH OR EARTH

COMPACTED TO 95% MAXIMUMDENSITY. BASE INSTALLED BY

PROFESSIONAL CONCRETE TRADEUNDER ELECTRICAL CONTRACT

2'-0"(MIN)

2'-6"

BREAK-AWAY BOLT DETAILSCALE: NO SCALEC

BREAK-AWAY BOLT DETAIL - PARKING LOTSCALE: NO SCALEC

3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2

sheet:

title:

revisions :

p r o j e c t # : 18.0405

d a t e : April 18, 2019

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND ISNOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDINGALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &MODELS THEREOF, ARE PROPRIETARY & CAN NOT BECOPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED INWHOLE OR IN PART WITHOUT THE SOLE AND EXPRESSWRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

USU EASTERNCAPITALIMPROVEMENTSSITE LIGHTING

4/18/2019

CONSTRUCTIONDOCUMENTS

LAS

T S

AV

ED

: 13

Mar

19

LAS

T S

AV

E 3

/13/

2019

T:\J

OB

S\2

0180

82 U

SU

EA

STE

RN

MIS

CE

LLA

NE

OU

S\0

1 D

RA

WIN

GS

\05

ELE

CTR

ICA

L\S

INE

SO

UR

CE

PR

OJE

CT\

SH

EE

TS\E

S50

1 E

LEC

TRIC

AL

SIT

E D

ETA

ILS

.DW

G

ES501

ELECTRICALSITE DETAILS

F USU PARKING LOT POLE BASE DETAILSCALE: NO SCALE

BID SET

Page 5: ES601 LIGHTING SCHEDULE & ELEVATION - gramoll.comgramoll.com/wp-content/uploads/2019/07/SITE_LIGHTING_Drawings_Updated... · emergency electrical metallic tubing end of line resistor

LIGHT FIXTURE SCHEDULETYPE MANUFACTURER/CATALOG NO. DESCRIPTION MOUNTING POWER LAMPS TYPE MANUFACTURER/CATALOG NO. DESCRIPTION MOUNTING POWER LAMPS

OW2- L6K GARDCO PWS-48L-300-NW-G2-2-UNV-SCBA EXTERIOR WALL FIXTURE; MULTI-VOLT, ELECTRONIC, DIMMABLE DRIVER; WALL 47 W 6000 LUMEN P4- L7K LUMEC MPTCCR-70W64LED4K-G2-LE4-UNV-CLO-(HS)-GY3TX/APR5W-12-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 4 OPTICAL DISTRIBUTION; UNIVERSAL POLE 73W 7000 LUMENEQUIVALENT WITH PRIOR APPROVAL TYPE 2 OPTICAL DISTRIBUTION NOMINAL LED P4- L7K(B1) NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 12' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED

4000K P4- L7K(B1F) COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KP4- L7K(H) FIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS; HOUSE SIDE

SHIELD WHERE (H) OPTIONS SHOWN ON DRAWINGS

OW3- L6K GARDCO PWS-48L-300-NW-G2-3-UNV-SCBA EXTERIOR WALL FIXTURE; MULTI-VOLT, ELECTRONIC, DIMMABLE DRIVER; WALL 47 W 6000 LUMEN P4- L72 LUMEC MPTCCR-80W48LED4K-R-LE4-UNV-CDMGP-CLO-GY3TX/APR5W-18-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 4 OPTICAL DISTRIBUTION; UNIVERSAL POLE 79W 7000 LUMENEQUIVALENT WITH PRIOR APPROVAL TYPE 3 OPTICAL DISTRIBUTION NOMINAL LED P4- L72D NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; FIELD PROGRAMMABLE SMART DIMMING FACTORY POLE BASE NOMINAL LED

4000K SET AS COORDINATED WITH OWNER; 18' ALUMINUM POLE; DECORATIVE BASE 4000KCOVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE

BANNER ARMS WHERE NOTED ON DRAWINGS--PRE-DRILLED FOR BANNER ARMS WITH BLANKCOVER IF ACCESSORY NOT SPECIFIED.

OW3- L10 GARDCO PWS-48L-500-NW-G2-3-UNV-SCBA EXTERIOR WALL FIXTURE; MULTI-VOLT, ELECTRONIC, DIMMABLE DRIVER; WALL 76 W 10000 LUMEN P4- L9K LUMEC MPTCCR-90W80LED4K-G2-LE4-UNV-CLO-(HS)-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 4 OPTICAL DISTRIBUTION; UNIVERSAL POLE 91W 9000 LUMENEQUIVALENT WITH PRIOR APPROVAL TYPE 3 OPTICAL DISTRIBUTION NOMINAL LED P4- L9K(H) NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE PARKING POLE BASE NOMINAL LED

4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS; HOUSE-SIDE SHIELD

WHERE (H) OPTION SHOWN ON DRAWINGS

OW4- L6K GARDCO PWS-48L-300-NW-G2-4-UNV-SCBA EXTERIOR WALL FIXTURE; MULTI-VOLT, ELECTRONIC, DIMMABLE DRIVER; WALL 47 W 6000 LUMEN P4- L9L LUMEC MPTCCR-90W80LED4K-G2-LE4-UNV-CLO-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 4 OPTICAL DISTRIBUTION; UNIVERSAL POLE 91W 9000 LUMENEQUIVALENT WITH PRIOR APPROVAL TYPE 3 OPTICAL DISTRIBUTION NOMINAL LED NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED

4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

OW4- L10 GARDCO PWS-48L-500-NW-G2-4-UNV-SCBA EXTERIOR WALL FIXTURE; MULTI-VOLT, ELECTRONIC, DIMMABLE DRIVER; WALL 76 W 10000 LUMEN P4- L12 LUMEC MPTCCR-135W80LED4K-G2-LE4-UNV-CLO-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 4 OPTICAL DISTRIBUTION; UNIVERSAL POLE 136W 12000 LUMENEQUIVALENT WITH PRIOR APPROVAL TYPE 3 OPTICAL DISTRIBUTION NOMINAL LED NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE PARKING POLE BASE NOMINAL LED

4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

P2- L3K LUMEC MPTCCR-35W32LED4K-G2-LE3-UNV-CLO-(HS)-GY3TX/APR5W-12-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 2 OPTICAL DISTRIBUTION; UNIVERSAL POLE 73W 7000 LUMEN P4- L1L LUMEC MPTCCR-135W80LED4K-G2-LE4-UNV-CLO-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 4 OPTICAL DISTRIBUTION; UNIVERSAL POLE 136W 12000 LUMENP2- L3K(H) NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 12' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED

COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS; HOUSE SIDE FIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

SHIELD WHERE (H) OPTIONS SHOWN ON DRAWINGS

P2- L7K LUMEC MPTCCR-70W64LED4K-G2-LE2-UNV-CLO-(HS)-GY3TX/APR5W-12-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 2 OPTICAL DISTRIBUTION; UNIVERSAL POLE 73W 7000 LUMEN P5- L7K LUMEC MPTCCR-70W64LED4K-G2-LE5-UNV-CLO-(HS)-GY3TX/APR5W-12-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 5 OPTICAL DISTRIBUTION; UNIVERSAL POLE 73W 7000 LUMENP2- L7K(H) NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 12' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED P5- L7K(B1) NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 12' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED

COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS FIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

P3- L7K LUMEC MPTCCR-70W64LED4K-G2-LE3-UNV-CLO-(HS)-GY3TX/APR5W-12-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 3 OPTICAL DISTRIBUTION; UNIVERSAL POLE 73W 7000 LUMEN P5- L9K LUMEC MPTCCR-90W80LED4K-G2-LE5-UNV-CLO-(HS)-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 5 OPTICAL DISTRIBUTION; UNIVERSAL POLE 91W 9000 LUMENP3- L7K(B1) NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 12' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE PARKING POLE BASE NOMINAL LEDP3- L7K(H) COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000K

FIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS; HOUSE SIDE FIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

SHIELD WHERE (H) OPTIONS SHOWN ON DRAWINGS

P3- L7S LUMEC MPTCCR-70W64LED4K-G2-LE3-UNV-CLO-(HS)-GY3TX/APR5W-MOD(12") DECORATIVE WALKWAY LUMINAIRE; TYPE 3 OPTICAL DISTRIBUTION; UNIVERSAL POLE 73W 7000 LUMEN P5- L9L LUMEC MPTCCR-90W80LED4K-G2-LE5-UNV-CLO-(HS)-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 5 OPTICAL DISTRIBUTION; UNIVERSAL POLE 91W 9000 LUMENNO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 12" ALUMINUM POLE SLIPFITTER OVER EXISTING EXISTING PIPE STUB NOMINAL LED NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE LANDSCAPE BASE NOMINAL LED

EMBEDDED POST; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

P3- L9K LUMEC MPTCCR-90W80LED4K-G2-LE3-UNV-CLO-(HS)-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 3 OPTICAL DISTRIBUTION; UNIVERSAL POLE 91W 9000 LUMEN P5- L12 LUMEC MPTCCR-135W80LED4K-G2-LE5-UNV-CLO-GY3TX/APR5W-20-LBC3 DECORATIVE WALKWAY LUMINAIRE; TYPE 5 OPTICAL DISTRIBUTION; UNIVERSAL POLE 136W 12000 LUMENNO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE PARKING POLE BASE NOMINAL LED NO EQUIVALENTS VOLTAGE, ELECTRONIC DRIVER; 20' ALUMINUM POLE; DECORATIVE BASE PARKING POLE BASE NOMINAL LED

COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000K COVER; COLOR AS SELECTED BY OWNER TO MATCH ORIGINAL SELECTION SAMPLE; 4000KFIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS FIELD INSTALLED BANNER ARMS WHERE NOTED ON DRAWINGS

NOTES

LIGHT FIXTURE ACCESSORY APPENDB1 LUMEC (RETRO-309)-129151-120-PLANTSUP-PS-BRTX LETTER APPENDED TO FIXTURE TYPE; DOUBLE BREAK-AWAY, BANNER ARMS (SINGLE SIDED); AS SPECIFIED N/A PER FIXTURE H HOUSE SIDE SHIELD INTERNALLY MOUNTED, HOUSE-SIDE SHIELD ACCESSORY FACTORY MOUNT N/A PER FIXTURE

BANNERARMS.COM MORSETTO BA-4-1-1-2-DIAMETER-3-LENGTH-1-COLOR SPREAD 58" ANTICIPATED SEPARATION TOP TO BOTTOM ARM; ARM EXTENSION IN DIRECTION TYPE IN FIXTURE TYPEEQUIVALENT ONLY WITH PRIOR APPROVAL INDICATED ON DRAWINGS; 39" ANTICIPATED LENGTH (CONTRACTOR TO VERIFY WITH

EXISTING FIXTURES; DECORATIVE BALL ENDCAP; DIAMETER TO MATCH POLE; FINISH

TO MATCH POLE (CUSTOM FINISH WHERE ARM NOT SOURCED FROM POLE MANUFACTURER)

F FLAG HOLDER LETTER APPENDED TO FIXTURE TYPE; FLAGHOLDER ACCESSORY FOR TILT-MOUNT FLAG; FACTORY MOUNT N/A PER FIXTUREFINISH TO MATCH POLE ON FIXTURE TYPE

NOTES-FIXTURE APPENDS ARE ADDED TO STANDARD FIXTURE TYPES. APPENDS ARE INTENDED TO MODIFY FIXTURE CATALOG NUMBERS GIVEN ABOVE AS NOTED IN APPEND DESCRIPTION

OW4-L102 3 1

OW4-L102

OW4-L102314

1. REMOVE WALL PACK FIXTURE.

2. PROVIDE NEW WALL MOUNT FIXTURE.

3. EXTEND EXISTING CIRCUIT SERVING REMOVED LIGHTS TO NEW FIXTURES. CONCEALCIRCUITING IN EXISTING BUILDING FINISHES. CUT, PATCH AND REPAIR AS REQUIRED.

4. CONNECT TO EXISTING CIRCUIT/LIGHTING CONTROL INDICATED.

ELEVATION KEYED NOTES

3 6 0 w e s t a s p e n a v e n u es a l t l a k e c i t y , u t a h 8 4 1 0 18 0 1 5 3 2 4 4 2 2

sheet:

title:

revisions :

p r o j e c t # : 18.0405

d a t e : April 18, 2019

UNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY AND ISNOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES, OR IMPLEMENTATION

THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDINGALL TECHNICAL DRAWINGS, GRAPHIC REPRESENTATIONS &MODELS THEREOF, ARE PROPRIETARY & CAN NOT BECOPIED, DUPLICATED, OR COMMERCIALLY EXPLOITED INWHOLE OR IN PART WITHOUT THE SOLE AND EXPRESSWRITTEN PERMISSION FROM METHOD STUDIO INC.

project:

E

D

C

B

A

E

D

C

B

A

1 2 3 4 5 6

1 2 3 4 5 6

USU EASTERNCAPITALIMPROVEMENTSSITE LIGHTING

4/18/2019

CONSTRUCTIONDOCUMENTS

LAS

T S

AV

ED

: 18

Apr

19

LAS

T S

AV

E 4

/18/

2019

T:\J

OB

S\2

0180

82 U

SU

EA

STE

RN

MIS

CE

LLA

NE

OU

S\0

1 D

RA

WIN

GS

\05

ELE

CTR

ICA

L\S

INE

SO

UR

CE

PR

OJE

CT\

SH

EE

TS\E

S60

1 LI

GH

TIN

G S

CH

ED

ULE

.DW

G

ES601

LIGHTINGSCHEDULE &ELEVATION

1 SESSIONS HALL EAST ELEVATIONSCALE: 1/8" = 1'-0"

BID SET