2
Type:ZSVInfrared Gas Analyzer Infrared Gas Analyzer For exhaust gas measurement and R&D ECNO:333b A maximum 5 components out of NOX, SO2, CO, CO2, CH4, and O2 can be measured simultaneously. The large LCD screen with clear display assures simple operation. Single-beam infrared gas analyzer having excellent stability is adopted. The O2 sensor is available in 2 types: Paramagnetic type and Zirconia type. The separate structure allows the analyzer unit and the pretreatment unit to be placed separately. Measurement can be taken continuously for up to 5 days. Compact size with excellent functionality and operability Portable gas analyzer with great mobility Analyzer unit Pretreatment unit Compact Type Compact Type

err

Embed Size (px)

DESCRIPTION

e

Citation preview

  • Type:ZSVInfraredGasAnalyzerInfraredGasAnalyzer

    For exhaust gas measurement and R&D

    ECNO:333b

    A maximum 5 components out of NOX, SO2, CO, CO2, CH4, and O2 can be measured simultaneously.The large LCD screen with clear display assures simple operation.Single-beam infrared gas analyzer having excellent stability is adopted.The O2 sensor is available in 2 types: Paramagnetic type and Zirconia type.The separate structure allows the analyzer unit and the pretreatment unit to be placed separately.Measurement can be taken continuously for up to 5 days.

    Compact size with excellent functionality and operabilityPortable gas analyzer with great mobility

    Analyzer unit Pretreatment unit

    CompactTypeCompactType

  • Simple probe or probe with primary filter

    CO2: 0 to 200ppm

    100%CO: 0 to 200ppm

    100%NO: 0 to 500ppm

    5000ppmSO2: 0 to 500ppm

    1%CH4: 0 to 1000ppm

    100%O2: 0 to 5% 25%Maximum range ratio 1:5 Switching between 3 ranges allowed.

    Analogoutput

    4 to 20mA DC or 0 to 1V DCConcentration of each component, Instantaneous value after O2 correctionOne-hour average value after O2 correction, Four-hour average value after O2 correction

    Communicationfunction

    RS232C (MODBUS protocol)

    Repeatability 0.5%FSPower supply voltage 100 to 115V AC or 200 to 240V AC, 50/60Hz

    Weight Analyzer unit: About 12kg, Pretreatment unit: About 18kg

    Outsidedimensions

    Analyzer unit: 204(H)x365(W)x514(D)mmPretreatment unit: 370(H)x365(W)x514(D)mm

    Tests for R&D such as combustion, biogas generation, and plant photosynthesis testsSimple measurement for control of exhaust gas from businesses placeControl and check of CA storage atmosphereCombustion exhaust gas measurement controlComparison with gas analyzers installed at site and backup

    Specifications Example configuration

    Major applications

    Zero gascalibration inlet

    Gas extractor

    Span gascalibration inlet

    Outputsignal

    Control signal (Cable connection)

    NOX/SO2

    Drainoutlet

    Analyzerunit

    Sampling unit

    Supplywaterinlet

    Bubbler

    Mistfilter

    Needlevalve

    Filter

    Filter Flowmeter

    Detector

    O2

    Measurementcell

    Measurementcell

    FilterFilter

    Power supply Power supply

    NOxconverter

    Flowmeter

    Detector

    Purgeinlet

    ExhaustgasoutletSample

    Pipingconnection

    SamplePipingconnection

    Electroniccooler

    Samplegas inlet

    P

    P

    P

    CO/CO2

    to us.Leave the measurement of

    Display unit(LCD with backlight)

    Operation key

    Flow checker (for checking sample gas ow rate)

    Power switch

    Drain outlet

    Gas extractor (option)

    Sampling gas inletStandard gas inlet

    Membrane lter

    Bubbler(Supply water inlet)

    Range select screen

    Zero span screen

    Menu screen

    Paperless recorder for storage of measurement data and analysis

    Associated equipment

    Type

    Number of recording points

    Input signal

    Storage medium

    PHF3 or 64 to 20mA DC, 1 to 5V DC,thermocouple, resistance bulbCompact flash (2GB max.)

    Simple probe Probe with primary filter

    Simple operation assuredby clear displaySimple operation assuredby clear display

    Measuredcomponent/measurementrange

    Gas extractor(option)

    Printed in Japan 2011-4/20FOLS

    International Sales Div.Sales GroupGate City Ohsaki, East Tower, 11-2, Osaki 1-chome,Shinagawa-ku, Tokyo 141-0032, Japanhttp://www.fujielectric.comPhone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425http://www.fujielectric.com/products/instruments/

    Information in this catalog is subject to change without notice.