TRAFFIC NODE 20P

•TRAFFIC NODE CONSISTS FROM 20 slots + 1 slot .•20 Slots can filled by MMU cards or NPU cards or LTU cards from slot 2 to slot 21 .•Power cables inserted to Slot 0 & Slot 1 .•Fan above link to cooling link with 2 power sources.

Page 3: Ericsson Link Presentation

TRAFFIC NODE 20P

Power cables on slot 0 & slot 1Power cables on slot 0 & slot 1

Page 4: Ericsson Link Presentation

TRAFFIC NODE 20P

NPU card which control on TN

NPU card which control on TN

Page 5: Ericsson Link Presentation

TRAFFIC NODE 20P

MMU cards that present link indoor

card

MMU cards that present link indoor

card

Page 6: Ericsson Link Presentation

TRAFFIC NODE 20P

IF cables connect RAU with MMU IF cables connect RAU with MMU

Page 7: Ericsson Link Presentation

TRAFFIC NODE 20P

XPIC cables connect between Vertical & Horizontal MMU

XPIC cables connect between Vertical & Horizontal MMU

Page 8: Ericsson Link Presentation

TRAFFIC NODE 20P

Fan with two power source for cooling TN

Fan with two power source for cooling TN

Page 9: Ericsson Link Presentation

Introduction to E/// linkE/// links divided into three types 1-TRAFFIC NODE 20P•-used at nodal sites with huge traffic•- have 20 slots + 1 slot for power .•-have 2 power sources .•-have fan with 2 power sources .•-compatible with Fiber STM .

Page 10: Ericsson Link Presentation

Introduction to E/// link

2-TRAFFIC NODE 6P-used at nodal sites with medium traffic .-have 6 slots + 1slot for power .-have 2 power sources .-have fan with 2 power sources .

Page 11: Ericsson Link Presentation

Introduction to E/// link

3-COMPACT NODE-used at end point sites with low traffic .-consists from 1 indoor card only .-have 2 power sources .-maximum number of E1=16E1 .

Page 12: Ericsson Link Presentation

Types of protection•Protection divided in three types1- Protection (2+2) - Used frequency as Vertical & Horizontal to duplicate the traffic .- Used 4 MMU cards . - Used 4 RAU outdoor .- Used XPIC cable to connect between Vertical & Horizontal MMU .- Used waveguide cable to connect between Vertical & Horizontal

RAU .- Used for huge traffic .

Page 13: Ericsson Link Presentation

Types of protection2-Protection (1+1)-used all frequency to transfer the traffic .-used 2 MMU cards .-used 2 RAU outdoor .-less interference than (2+2) protection .

Page 14: Ericsson Link Presentation

Types of protection

3-Protection (1+0)-used all frequency to transfer the traffic .-used 1 MMU card .-used 1 RAU outdoor .-less secure than (1+1) protection

Page 15: Ericsson Link Presentation

HOW TO ACESS TO HOW TO ACESS TO E/// LINK (20P)E/// LINK (20P)

Page 16: Ericsson Link Presentation

HOW TO ACCESS TO E/// LINK

ACCESS from TR-7 LAN port by Ethernet

cable

ACCESS from TR-7 LAN port by Ethernet

cable

Page 17: Ericsson Link Presentation

HOW TO ACCESS TO E/// LINK

PC IP (LINK IP+1)PC IP (LINK IP+1)

SUBNET MASK AS ShownSUBNET MASK AS Shown

LINK IP As ShownLINK IP As Shown

Page 18: Ericsson Link Presentation

HOW TO ACCESS TO E/// LINK

ACCESS TO MINI-LINK CRAFT program

ACCESS TO MINI-LINK CRAFT program

Page 19: Ericsson Link Presentation

HOW TO ACCESS TO E/// LINK

Insert link IP as shownInsert link IP as shown

Username=control_userUsername=control_user

Password=ericssonPassword=ericsson

Page 20: Ericsson Link Presentation

HOW TO ACESS TO HOW TO ACESS TO E/// LINK (20P)E/// LINK (20P)

From O&M port by using

USB-MINI cable

From O&M port by using

USB-MINI cable

Page 21: Ericsson Link Presentation

HOW TO ACESS TO HOW TO ACESS TO E/// LINK (20P)E/// LINK (20P)

IP=10.0.0.1User= control_user

Password= ericsson

IP=10.0.0.1User= control_user

Password= ericsson

Page 22: Ericsson Link Presentation

How to upload configuration file to PC

From tools ftp server in new windowFrom tools ftp server in new window

Press startPress start

Before take any action in TN must save this file

Page 23: Ericsson Link Presentation

How to upload configuration file to PC

From TN configureload configurationFrom TN configureload configuration

Page 24: Ericsson Link Presentation

How to upload configuration file to PC

Upload to ftp serverUpload to ftp server

User name= defualtPassword= defualt

User name= defualtPassword= defualt

Choose local serverInsert PC IP (10.0.0.2 in case of use

mini USB cable )

Choose local serverInsert PC IP (10.0.0.2 in case of use

mini USB cable )

Press ApplyPress Apply

Page 25: Ericsson Link Presentation

How to upload configuration file to PC

Press update progress several times

Press update progress several times

Page 26: Ericsson Link Presentation

How to upload configuration file to PC

File saved in c:\tn_ftp_home\

tn_backup_configuration

File saved in c:\tn_ftp_home\

tn_backup_configuration

Page 27: Ericsson Link Presentation

HOW to Restart TN

From TN tools restartFrom TN tools restart

Page 28: Ericsson Link Presentation

HOW to Restart TN

Warm restart =restart TN without down the

traffic

Warm restart =restart TN without down the

traffic

Cold restart =restart TN with down the

traffic

Cold restart =restart TN with down the

traffic

Page 29: Ericsson Link Presentation

How to detect SN & product number for any card for TN

From TN tools inventoryFrom TN tools inventory

Page 30: Ericsson Link Presentation

How to detect SN & product number for any card for TN

Page 31: Ericsson Link Presentation

HOW TO Gets LPM FOR link

Open MMU2 H open RAU IF from switch

Choose performance

Open MMU2 H open RAU IF from switch

Choose performance

Page 32: Ericsson Link Presentation

HOW TO GETS LPM FOR TN

PRESS More than 15 minute intervals

PRESS More than 15 minute intervals

Page 33: Ericsson Link Presentation

HOW TO GETS LPM FOR TN

Press (CTRL+A) then (CTRL+C) to copy

Press (CTRL+A) then (CTRL+C) to copy

Page 34: Ericsson Link Presentation

HOW TO GETS LPM FOR TN

Open new Excel sheet & press (CTRL+V) to paste Open new Excel sheet & press (CTRL+V) to paste

Page 35: Ericsson Link Presentation

HOW TO GETS LPM FOR TN

After we paste Values then press save to save the file

After we paste Values then press save to save the file

Page 36: Ericsson Link Presentation

HOW TO GETS NOTIFICATION HISTORY

From TN View Notification History

From TN View Notification History

Page 37: Ericsson Link Presentation

HOW TO GETS NOTIFICATION HISTORY

Page 38: Ericsson Link Presentation

HOW TO GETS NOTIFICATION HISTORY

Press (CTRL+A) then press (CTRL+C)

to copy

Press (CTRL+A) then press (CTRL+C)

to copy

Page 39: Ericsson Link Presentation

HOW TO GETS NOTIFICATION HISTORY

Open new EXCEL Sheet press (CTRL+V) to paste

Open new EXCEL Sheet press (CTRL+V) to paste

Page 40: Ericsson Link Presentation

HOW TO GETS NOTIFICATION HISTORY

Press Save to save the filePress Save to save the file

Page 41: Ericsson Link Presentation

HOW to restart MMU

From MMU right click Tools Restart

From MMU right click Tools Restart

Page 42: Ericsson Link Presentation

HOW to restart MMU

Press Cold RestartPress Cold Restart

Page 43: Ericsson Link Presentation

How to gets link RX & TX frequency

From Radio links choose slot configure

Radio link

From Radio links choose slot configure

Radio link

Page 44: Ericsson Link Presentation

How to gets link RX & TX frequency & Modulation

Page 45: Ericsson Link Presentation

How to gets link RX & TX frequency & Modulation

Page 46: Ericsson Link Presentation

HOW TO GETS TX & RX level

Press left click on MMU that present

link

Press left click on MMU that present

link

Page 47: Ericsson Link Presentation

HOW TO GETS TX & RX level

Gets TX & RX value

Gets TX & RX value

Page 48: Ericsson Link Presentation

HOW TO MAKE LOOPS

Press on loopsPress on loops

Page 49: Ericsson Link Presentation

HOW TO MAKE LOOPS

Page 50: Ericsson Link Presentation

HOW TO MAKE LOOPS

Press on RF icon to make loop on RAU to

check both (RAU+IF+MMU)

Press on RF icon to make loop on RAU to

check both (RAU+IF+MMU)

Page 51: Ericsson Link Presentation

HOW TO MAKE LOOPS

Press Save to confirm loop

Press Save to confirm loop

Page 52: Ericsson Link Presentation

HOW TO MAKE LOOPS

Alarms should cleared on (MMU+IF+RAU) except

(HCC alarm)

Alarms should cleared on (MMU+IF+RAU) except

(HCC alarm)

Page 53: Ericsson Link Presentation

How to change MMU

Press on BR buttonPress on BR button

Page 54: Ericsson Link Presentation

How to change MMU

BR orange LED should be lights up

BR orange LED should be lights up

Page 55: Ericsson Link Presentation

How to change MMU

Upper and lower Screw should be

detach

Upper and lower Screw should be

detach

Page 56: Ericsson Link Presentation

How to change MMU

Upper and lower clasps should be

raises

Upper and lower clasps should be

raises

Page 57: Ericsson Link Presentation

How to change MMU

Release IF cable & XPIC cable

Release IF cable & XPIC cable

Page 58: Ericsson Link Presentation

How to change MMU

Remove MMU card & insert new MMU card and connect IF cable &

XPIC cable

Remove MMU card & insert new MMU card and connect IF cable &

XPIC cable

Page 59: Ericsson Link Presentation

Kinds of alarms at TN

Critical alarmCritical alarm

Major alarmMajor alarm

Minor alarmMinor alarm

Warning alarmWarning alarm

Intermediate alarmIntermediate alarm

Page 60: Ericsson Link Presentation

How to switch between 2 MMU

Press on switch mode Press on switch mode

Page 61: Ericsson Link Presentation

How to switch between 2 MMU

Change switch mode from Automatic manual

Change switch mode from Automatic manual

Page 62: Ericsson Link Presentation

How to switch between 2 MMU

After select manual mode press Save

After select manual mode press Save

Page 63: Ericsson Link Presentation

How to switch between 2 MMU

Choose Active MMU from MMU1 to MMU2

Choose Active MMU from MMU1 to MMU2

Page 64: Ericsson Link Presentation

How to switch between 2 MMU

After change to MMU2 press Save

After change to MMU2 press Save

Page 65: Ericsson Link Presentation

How to switch between 2 MMU

From switch mode change from Manual

to Automatic

From switch mode change from Manual

to Automatic

Page 66: Ericsson Link Presentation

How to switch between 2 MMU

Then press Save to save changes and now we

switch between 2 MMU

Then press Save to save changes and now we

switch between 2 MMU

Page 67: Ericsson Link Presentation

How to check interference between vertical & Horizontal MMU

•If RX level for Vertical MMU on link = 30 db . •We disconnect Vertical MMU from other side .•Check RX level for Vertical MMU on link <= 60 db .•If RX level > 60 db there are interference between Vertical &Horizontal .

Page 68: Ericsson Link Presentation

How to check interference between different links

•Disconnect both Vertical & Horizontal MMU .•Check RX level on other side .•RX level should less than 95 db .•If RX level more than 95 db there are interference from another link .