Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
Gasoline Analysis: oxygenates, aromatics, OCTANE boosters, RON, MON, AKI, RVPE, VLI, density and distillation properties …
Diesel Fuel Analysis: FAME, FAEE, distinction between FAME and vegetable oil, aromatics, PNA, CETANE number and index …
Jet Fuel Analysis: aromatics, PNA, FAME, freezing point, flash point …
all this in seconds with a portable analyzer in full compliance with the latest standards such as ASTM D5845, D6277, D7806, EN 238, EN 14078 …
ERASPEC SPECTRAL FUEL ANALYSIS IN SECONDS
Fingerprint Your Fuel in Seconds
PERFORMANCE YOU CAN RELY ON
NEW! Biodiesel/FAME measurements
according to ASTM D7806
SPECTRAL FUEL ANALYSIS IN SECONDS
Detailed FTIR AnalysisERASPEC uses a patented rugged Fourier transform infrared (FTIR) spectro meter to deliver laboratory precision in a portable instrument. At the single push of a button it analyzes your fuel for over 40 parameters within seconds. ERASPEC directly measures the significant gasoline com-ponents, such as aromatics, oxygenates and octane boosters. In addition, it determines all important gasoline parameters. Those include RON, MON, AKI, RVPE, VLI and distillation properties to name but a few. In Diesel fuel the instrument directly measures total aromatics, polynuclear aromatics and the cetane improvers 2-EHN and IPN. Biodiesel measurements deliver results for the FAME and FAEE concentrations. The instrument then uses the measurements to calculate the cetane number, cetane index and the distillation fractions. Jet fuel analysis additionally gives results for the freezing, flash- and smoke points. The built-in oscillating U-tube density meter (ASTM D7777, ISO 15212) accurately mea-sures fuel density and allows displaying the results in Vol% as well as in Mass%.
Huge Expandable DatabaseERASPEC comes preconfigured with a huge database of several hundred international calibration samples. But we would not let this be your limit. Therefore, we made it easy to drive ERASPEC’s excellent result accuracy even further: It is easily possible to add as many samples of known concen-trations or properties to the database as are required. By training ERASPEC with new samples you can even define completely new parameters for the results. This process is so simple, you should really give it a try.
Compliant Biodiesel TestingDue to governmental regulations as well as influences on Diesel fuel proper-ties it is important to monitor Biodiesel concentrations in Diesel blends. ERASPEC analyzes Biodiesel across a range of 0-65 Vol%, which covers all blend ratios in practical use. It fully complies with the brand new ASTM D7806 standard and can also directly determine Biodiesel according to EN 14078. ERASPEC analyzes the sample for contaminations with vegetable oil and displays a notification if vegetable oil is detected.ERASPEC is calibrated with a matrix of Biodiesel produced from canola oil. To increase the measurement accuracy even further, it offers a simple func-tionality to add additional calibration models for Biodiesel produced from other sources, such as soybeans.
With several hundred instal-lations in over 50 countries
ERASPEC has already proven its reliability and durability.
Directly compare and evaluate spectra on the
7” color touch screen.
SPECTRAL FUEL ANALYSIS IN SECONDS ERASPEC
Optimized Design for Unmatched Precision
Autosampler for Unattended AnalysisThe 10-position autosampler lets youmaximize your sample throughput while saving precious operator time. The sampler is directly attached and performs measure-ments without operator intervention.
Gasoline, Diesel fuel and jet fuel show highly differ-ent IR signal intensities in measurements. To achieve highest precision for all fuel types ERASPEC uses a patented, purpose-designed single or dual transmis-sion cell. Gasoline, which exhibits higher signal intensi-ties, is measured through a 20 µm cell whereas Diesel and jet fuel measurements are performed with a 100 µm cell to enhance their low signal intensity. For the analysis of special Ethanol, Methanol or synthetic fuels ERASPEC automatically selects the ideal cell.
High-precision measurements also require the best signal-to-noise ratio to accurately determine concen-trations of individual compounds. ERASPEC therefore uses an optimized spectral reso-lution of 4 cm-1 for low-noise fuel measurements in full compliance with latest standards. Additionally, ERASPEC automatically selects the best IR signal of each component for evaluation. These features com-bined result in a superior signal-to-noise ratio and a truly comprehensive measurement range.
SPECTRAL FUEL ANALYSIS IN SECONDS
Oxygenates** RangeMTBE 0 – 20 v%ETBE 0 – 25 v%TAME 0 – 25 v%DIPE 0 – 20 v%Methanol 0 – 15 v%Ethanol 0 – 25 v%tert-Butanol 0 – 25 v%Isopropanol 0 – 20 v%2-Butanol 0 – 25 v%All other oxygenates 0 – 25 v%
Total Parameters** RangeTotal oxygen 0 – 12 m%Total olefins 0 – 80 v%Total aromatics 0 – 60 v%Total saturates 0 – 100 v%Di-olefins 0 – 15 v%
Aromatics** RangeBenzene 0 – 10 v%Toluene 0 – 25 v%m-Xylene 0 – 25 v%o-Xylene 0 – 25 v%p-Xylene 0 – 25 v%Ethylbenzene 0 – 20 v%Propylbenzene 0 – 20 v%2-Ethyltoluene 0 – 20 v%3-Ethyltoluene 0 – 20 v%4-Ethyltoluene 0 – 20 v%Pseudocumene 0 – 20 v%Mesitylene 0 – 20 v%Hemellitol 0 – 20 v%Napthalene 0 – 10 v%Durene 0 – 20 v%Iso-Durene 0 – 20 v%All other aromatics 0 – 20 v%
Octane Boosters** RangeDCPD 0 – 15 v%MMT 0 – 10000 mg/lCMT 0 – 10000 mg/lManganese 0 – 2500 mg/lN-Methylaniline 0 – 15 v%Aniline 0 – 15 v%
Available Fuel Parameters
* The range and repeatability for all determined properties depend on the database used** Lowest concentrations correspond to the limit of detection (LOD), all concentrations in Vol% and Mass%
Properties* RangeCetane number 20 – 80Cetane index 20 – 80Density 0 – 3 g/cm3
Distillation: IBP, T10, T50, T65, T85, T90, T95, FBPEvaporation: E250, E350Easy addition of UNLIMITED user-defined parameters
Parameters** RangeTotal aromatics 0 – 60 v%Poly Nuclear Aromatics (PNA) 0 – 50 v%Cetane improver (2-EHN, IPN) 50 – 20000 mg/lBiodiesel (FAME, FAEE) 0 – 65 v%Differentiation of FAME from vegetable oil
Properties* RangeFreezing point -25 – -75 °CFlash point 25 – 65 °CSmoke point 19 – 29 mmViscosity @ 20 °C 1.2 – 2.1 mPasViscosity @ -20 °C 2.4 – 4.5 mPasDensity 0 – 3 g/cm3
Distillation: IBP, T10, T50, T65, T85, T90, T95, FBPEasy addition of UNLIMITED user-defined parameters
Parameters** RangeFAME 0 – 6 v%Total aromatics 0 – 60 v%Poly Nuclear Aromatics (PNA) 0 – 10 v%
Jet Fuel ModuleDiesel Fuel Module
Properties* RangeRON (Research Octane Number) 70 – 110MON (Motor Octane Number) 60 – 100AKI (Anti Knock Index) 65 – 105RVPE & DVPE 35 - 100Density 0 – 3 g/cm3
Properties*Distillation points: IBP, T10, T50, T90, FBPEvaporation points: E70, E100, E150, E200, E300Driveability Index, Vapor Lock Index (VLI)VOC emission calculatorEasy addition of UNLIMITED user-defined parameters
Gasoline Module
SPECTRAL FUEL ANALYSIS IN SECONDS ERASPEC
Available test methods ASTM D5845, D6277, D7777, D7806, EN 238, EN 14078, ISO 15212, IP 559
Excellent correlation to ASTM D86, D323, D613, D976, D2699, D2700, D4814, D5191,
D6378, ISO 3405, ISO 5163, ISO 5164, ISO 5165, EN 13016
Spectrometer type NIR/MID-FTIR interferometer (patented laser and temperature controlled design),
16,384 data points, scanning range: 450 to 7,000 cm-1
Measurement cell Optimized single or dual-position cell for gasoline, Diesel fuel and jet fuel
Calibration Factory calibrated with a matrix of several hundred international fuels
Spectral libraries Easy addition, expansion and exchange of individual fuel libraries
Warm-up time 30 seconds
Measurement time 60 seconds
Sample introduction Directly from the sample container by an integrated pump
Cleaning Automatic rinsing with next sample or solvent
Filter Integrated 16 µm filter
Sample volume 10 ml
Display Industry proven 7” color touch screen
Interfaces Built-in PC with Ethernet, USB and RS232 interfaces
Direct LIMS connectivity via LAN and output to printer or PC
Optional input by external keyboard, mouse and barcode reader
Remote control Remote service capability via Ethernet interface
Result database 50,000 detailed test reports and spectra storable in internal memory
Display of fuel spectra Several fuel spectra can be compared directly on screen
Operators 100 operator names storable, 6 user-levels, password protection
Alarm tracking All messages are stored in the database together with the results
Power requirements Auto-switching 85-264 V AC, 47-63 Hz, 70 W (multi-voltage power supply)
Field application: 12 V/9 A DC (vehicle battery)
Operating conditions Temperature range 5-45°C, Humidity up to 90% RH, non-condensing
Dimensions / Weight 22 x 32 x 28 cm (8.7 x 12.6 x 11 in) / 8 kg (17.6 lb)
Accessories ERASOFT RCS - PC software for multi-instrument networking, result, spectra and
libraries download, view and analysis of spectra, software update, etc.
Carrying case for safe transport and storage
DC adaptor for +12 V vehicle battery operation
Printer (USB laser printer, parallel DeskJet or dot matrix)
Technical Specifications
Due to continuing product development, specifications are subject to change. All eralytics products are manufactured under ISO 9001 regulations and are CE, ROHS and UL/CSA compliant.
SPECTRAL FUEL ANALYSIS IN SECONDS
Fast & Easy Operation
All eralytics analyzers use an intuitive menu structure that is easy to navi-gate. Samples need no prior preparation and measurements are done fully automated.
The results are displayed immediately after the test on the large and user-friendly color touch screen. An internal memory holds the measurement results. For convenience, data can be directly saved to USB memory sticks for further processing or a thorough analysis. The data format is compatible with most PC spreadsheet programs, such as Microsoft© Excel. Spectra can be saved in JCAMP-DX format. Customized print-out designs are available for easy direct printing.
Fuel testing in four easy steps with ERASPEC
• Select the fuel type
• Select/enter sample ID and operator name
• Put the inlet tubing into the sample
• Press RUN to start the fully automated measurement
ERASOFT RCS Remote Control PC Software
The RCS software by eralytics is the ideal tool for operating one or more eralytics analyzers via a PC. As an alternative to LIMS, it allows for conve-nient data transfer and fast analysis of results. It ideally supports the cutting-edge technology and functionalities built into the eralytics instruments.
PERFORMANCE YOU CAN RELY ON
• Multi-instrument networking
• Remote control
• Fast & easy data transfer (results, settings, spectra, libraries, etc.)
• Software upgrade
• Backup/restore for configurations and unit parameters
SPECTRAL FUEL ANALYSIS IN SECONDS ERASPEC
Compact Stand-Alone Analyzer
All eralytics instruments are compact stand-alone analyzers with a built-in industrial PC. They represent the latest in technology, designed for long-term, maintenance-free operation. Of course, all eralytics analyzers use cutting-edge industry technology and provide universal data transfer op-tions. Ethernet and USB interfaces allow advanced data management and connectivity to PCs, modern printers, keyboards, PC-mice, barcode read-ers, or other external equipment.
Direct LIMS Communication
A direct out-of-the-box connection to LIMS (Laboratory Information Man-agement System) is established with a standard Ethernet cable. No extra software or PC are necessary.
True Portability
The small footprint of the eralytics instruments makes them the first choice for use in the lab and on-site. Lightweight and built with an integrated carry-ing handle they are ideally suited for mobile applications.
Large Results Memory
Data are stored safely in the large results memory, which holds many thou-sand records. Six user levels and a state-of-the-art password technology protect your test result data from accidental deletion.
Service and Remote Control over the Internet
At the push of a button, firmware and software updates can be downloaded from the internet. The internet connection also allows to remotely control eralytics analyzers or to perform standard service activities.
ERASPEC OILTM
Portable FTIR oil analysis in seconds - The first truly portable stand-alone analyzer with a patented rugged FTIR spectrometer for high-speed lubricant oil condition moni-toring in full compliance with ASTM, DIN and JOAP methods. With its lightweight build and small footprint, it is a welcome addition to mobile laboratories to deliver a detailed fingerprint of used oil on-site and check degradation and contamination within seconds.
eralytics® GmbH
Lohnergasse 3, 1210 Vienna, AustriaPhone: +43 1 890 50 330Fax: +43 1 890 50 [email protected]
eralytics instruments are available worldwide. An international network of over 50 authorized and well trained dealers is ready to answer your inquiries and to offer local support and service.
ERAFLASH TM
The safe side of flashpoint testing - The first and only flashpoint tester on the market to cover the wide temperature range of -25 to 420°C in a single analyzer. Its small sample size and the continuously closed measuring chamber (ASTM D6450 & D7094) guarantee maximum safety and speed at minimum costs.
ERACHECK TM
CFC-free oil-in-water testing - The portable analyzer with the patented QCL-IR technol-ogy for an extraction with the inexpensive and CFC-free solvent Cyclohexane. With its high speed and precision, it is the instrument of choice to detect even sub-ppm concentrations of total petroleum hydrocarbons (TPH) or total oil & grease (TOG) in water in full compli-ance with ASTM D7678.
Welcome to a New Era of Petroleum TestingUpgrade your lab to the 21st century. Leverage the accuracy, speed and comfortable ease of use that are characteristic of eralytics instruments.
ERAVAP TM
Vapor pressure testing at its best - The vapor pressure analyzer for virtually all types of fuel, from gasoline to LPG, that also handles crude oil, and takes all tests in full com-pliance with the latest ASTM and EN ISO standards. With its unmatched precision and measuring stability (r = 0.3 kPa, R = 0.7 kPa) it is the preferred analyzer in laboratories across the world.