58
User’s Manual AQ6370 Viewer IM 735371-01E 10th Edition

er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

User’sManual AQ6370 Viewer

IM 735371-01E10th Edition

Page 2: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

iIM 735371-01E

Thank you for purchasing the AQ6370 Viewer.This user’s manual lists precautions that must be taken during use, and contains useful information about the functions and operating procedures of the software program. To ensure correct use, please read this manual thoroughly during operation.Keep this manual in a safe place for quick reference in the event a question arises.In addition to this manual, the AQ6370 Viewer Installation Manual (IM 735371-02E) is provided for installing and running the AQ6370 Viewer.For information about the handling precautions, functions, and operating procedures of the Optical Spectrum Analyzer (AQ6370 series) and the handling and operating procedures for Windows, see the manuals for those products.

Notes• Thecontentsofthismanualaresubjecttochangewithoutpriornoticeasaresultof

continuing improvements to the instrument’s performance and functions. The figures given in this manual may differ from those that actually appear on your screen.

• Everyefforthasbeenmadeinthepreparationofthismanualtoensuretheaccuracyof its contents. However, should you have any questions or find any errors, please contact your nearest YOKOGAWA dealer.

• CopyingorreproducingalloranypartofthecontentsofthismanualwithoutYOKOGAWA’s permission is strictly prohibited.

Trademarks• Microsoft,MicrosoftInternetExplorer,MS-DOS,andWindowsareeitherregistered

trademarksortrademarksofMicrosoftCorporationintheUnitedStatesand/orothercountries.

• Adobe,Acrobat,andPostScriptaretrademarksofAdobeSystemsIncorporated.• Forpurposesofthismanual,the®andTMsymbolsdonotaccompanytheir

respective registered trademark names or trademark names.• Othercompanyandproductnamesareregisteredtrademarksortrademarksoftheir

respective holders.

Revisions• 1stEdition October2006• 2ndEdition May2008• 3rdEdition October2008• 4thEdition February2010• 5thEdition October2010• 6thEdition May2014• 7thEdition March2015• 8thEdition March2016• 9thEdition March2017• 10thEdition May2018

10thEdition:May2018(YMI)AllRightsReserved,Copyright©2006,YokogawaElectricCorporationAllRightsReserved,Copyright©2010,YokogawaTest&MeasurementCorporation

Page 3: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

ii IM 735371-01E

Terms and Conditions of the Software License

YokogawaElectricCorporationandYokogawaTest&MeasurementCorporation,Japanesecorporations (hereinaftercalled “Yokogawa”),grantspermission touse thisYokogawaSoftwareProgram(hereinaftercalledthe“LicensedSoftware”)totheLicenseeontheconditionsthattheLicenseeagreestothetermsandconditionsstipulatedin Article 1 hereof.You,astheLicensee(hereinaftercalled“Licensee”),shallagreetothefollowingtermsandconditionsforthesoftwarelicense(hereinaftercalledthe“Agreement”)basedontheuseintendedfortheLicensedSoftware.PleasenotethatYokogawagrantstheLicenseepermissiontousetheLicensedSoftwareunderthetermsandconditionshereinandinnoeventshallYokogawaintendtosellortransfertheLicensedSoftwaretotheLicensee. LicensedSoftwareName: USBComplianceTestSoftware(Model701985/F30) NumberofClientLicense:1

Article1(ScopeCoveredbytheseTermsandConditions)1.1ThetermsandconditionsstipulatedhereinshallbeappliedtoanyLicenseewhopurchasestheLicensedSoftwareontheconditionthattheLicenseeconsentstoagree

to the terms and conditions stipulated herein.1.2The“LicensedSoftware”hereinshallmeanandincludeallapplicableprogramsanddocumentation,withoutlimitation,allproprietarytechnology,algorithms,andknow-

how such as a factor, invariant or process contained therein.

Article2(GrantofLicense)2.1Yokogawagrants theLicensee, for thepurposeof singleuse,non-exclusiveandnon-transferable licenseof theLicensedSoftwarewith the license feeseparately

agreeduponbybothparties.YokogawaallowstheLicenseetoinstallonlyoneinstanceofthesoftwareforuseononedevice,whetherthatdeviceisphysicalorvirtual.IftheLicenseewanttousethesoftwareonmorethanonevirtualdevice,theLicenseemustobtainaseparateLicensedSoftwareforeachinstance.

2.2TheLicenseeis,unlessotherwiseagreedinwritingbyYokogawa,notentitledtocopy,change,sell,distribute,transfer,orsublicensetheLicensedSoftware.2.3TheLicensedSoftwareshallnotbecopiedinwholeorinpartexceptforkeepingone(1)copyforback-uppurposes.TheLicenseeshallsecureorsupervisethecopyof

theLicensedSoftwarebytheLicenseeitselfwithgreat,strict,andduecare.2.4InnoeventshalltheLicenseedump,reverseassemble,reversecompile,orreverseengineertheLicensedSoftwaresothattheLicenseemaytranslatetheLicensed

Softwareintootherprogramsorchangeitintoaman-readableformfromthesourcecodeoftheLicensedSoftware.UnlessotherwiseseparatelyagreedbyYokogawa,YokogawashallnotprovidetheLicenseethesourcecodefortheLicensedSoftware.

2.5TheLicensedSoftwareanditsrelateddocumentationshallbetheproprietarypropertyortradesecretofYokogawaorathirdpartywhichgrantsYokogawatherights.InnoeventshalltheLicenseebetransferred,leased,sublicensed,orassignedanyrightsrelatingtotheLicensedSoftware.

2.6YokogawamayuseoraddcopyprotectioninorontotheLicensedSoftware.InnoeventshalltheLicenseeremoveorattempttoremovesuchcopyprotection.2.7TheLicensedSoftwaremayincludeasoftwareprogramlicensedforre-usebyathirdparty(hereinaftercalled“ThirdPartySoftware”,whichmayincludeanysoftware

program from affiliates of Yokogawa made or coded by themselves.) In the case that Yokogawa is granted permission to sublicense to third parties by any licensors (sub-licensor)oftheThirdPartySoftwarepursuanttodifferenttermsandconditionsthanthosestipulatedinthisAgreement,theLicenseeshallobservesuchtermsandconditionsofwhichYokogawanotifiestheLicenseeinwritingseparately.

2.8InnoeventshalltheLicenseemodify,removeordeleteacopyrightnoticeofYokogawaanditslicensercontainedintheLicensedSoftware,includinganycopythereof.

Article3(RestrictionofSpecificUse)3.1TheLicensedSoftware shall not be intended specifically to bedesigned, developed, constructed,manufactured, distributedormaintained for thepurposeof the

following events: a) Operation of any aviation, vessel, or support of those operations from the ground;, b) Operationofnuclearproductsand/orfacilities;, c) Operationofnuclearweaponsand/orchemicalweaponsand/orbiologicalweapons;or d) Operation of medical instrumentation directly utilized for humankind or the human body.3.2Even if theLicenseeuses theLicensedSoftware for thepurposes in theprecedingParagraph3.1,Yokogawahasno liability toor responsibility foranydemandor

damagearisingoutoftheuseoroperationsoftheLicensedSoftware,andtheLicenseeagrees,onitsownresponsibility,tosolveandsettletheclaimsanddamagesandtodefend,indemnifyorholdYokogawatotallyharmless,fromoragainstanyliabilities,losses,damagesandexpenses(includingfeesforrecallingtheProductsandreasonable attorney’s fees and court costs), or claims arising out of and related to the above-said claims and damages.

Article4(Warranty)4.1TheLicenseeshallagreethattheLicensedSoftwareshallbeprovidedtotheLicenseeonan“asis”basiswhendelivered.Ifdefect(s),suchasdamagetothemedium

of theLicensedSoftware, attributable toYokogawa is found,Yokogawaagrees to replace, freeof charge, anyLicensedSoftwareon condition that thedefectiveLicensedSoftwareshallbereturnedtoYokogawa’sspecifiedauthorizedservicefacilitywithinseven(7)daysafteropeningthePackageattheLicensee’sexpense.AstheLicensedSoftwareisprovidedtotheLicenseeonan“asis”basiswhendelivered,innoeventshallYokogawawarrantthatanyinformationonorintheLicensedSoftware, including without limitation, data on computer programs and program listings, be completely accurate, correct, reliable, or the most updated.

4.2NotwithstandingtheprecedingParagraph4.1,whenthirdpartysoftwareisincludedintheLicensedSoftware,thewarrantyperiodandtermsandconditionsthatapplyshall be those established by the provider of the third party software.

4.3WhenYokogawadecidesinitsownjudgementthatitisnecessary,YokogawamayfromtimetotimeprovidetheLicenseewithRevisionupgradesandVersionupgradesseparatelyspecifiedbyYokogawa(hereinaftercalled“Updates”).

4.4NotwithstandingtheprecedingParagraph4.3,innoeventshallYokogawaprovideUpdateswheretheLicenseeoranythirdpartyconductedrenovationorimprovementoftheLicensedSoftware.

4.5THEFOREGOINGWARRANTIESAREEXCLUSIVEAND INLIEUOFALLOTHERWARRANTIESOFQUALITYANDPERFORMANCE,WRITTEN,ORAL,ORIMPLIED,ANDALLOTHERWARRANTIESINCLUDINGANYIMPLIEDWARRANTIESOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSEAREHEREBYDISCLAIMEDBYYOKOGAWAANDALLTHIRDPARTIESLICENSINGTHIRDPARTYSOFTWARETOYOKOGAWA.

4.6CorrectionofnonconformityinthemannerandfortheperiodoftimeprovidedaboveshallbetheLicensee’ssoleandexclusiveremedyforanyfailureofYokogawatocomplywithitsobligationsandshallconstitutefulfillmentofallliabilitiesofYokogawaandanythirdpartylicensingtheThirdPartySoftwaretoYokogawa(includinganyliabilityfordirect,indirect,special,incidentalorconsequentialdamages)whetherinwarranty,contract,tort(includingnegligencebutexcludingwillfulconductorgrossnegligencebyYokogawa)orotherwisewithrespecttoorarisingoutoftheuseoftheLicensedSoftware.

Article 5 (Infringement)5.1Ifandwhenanythirdpartyshoulddemandinjunction,initiatealawsuit,ordemandcompensationfordamagesagainsttheLicenseeunderpatentright(includingutility

modelright,designpatent,andtrademark),copyright,andanyotherrightsrelatingtoanyoftheLicensedSoftware,theLicenseeshallnotifyYokogawainwritingtothat effect without delay.

5.2InthecaseoftheprecedingParagraph5.1,theLicenseeshallassigntoYokogawaallof therightstodefendtheLicenseeandtonegotiatewiththeclaimingparty.Furthermore, theLicenseeshallprovideYokogawawithnecessary informationoranyotherassistanceforYokogawa’sdefenseandnegotiation. IfandwhensuchaclaimshouldbeattributabletoYokogawa,subjecttothewrittennoticetoYokogawastatedintheprecedingParagraph5.1,YokogawashalldefendtheLicenseeandnegotiatewiththeclaimingpartyatYokogawa’scostandexpenseandberesponsibleforthefinalsettlementorjudgmentgrantedtotheclaimingpartyintheprecedingParagraph5.1.

5.3Whenanyassertionorallegationoftheinfringementofthethirdparty’srightsdefinedinParagraph5.1ismade,orwhenatYokogawa’sjudgmentthereispossibilityofsuchassertionorallegation,Yokogawawill,atitsowndiscretion,takeanyofthefollowingcountermeasuresatYokogawa’scostandexpense.

a) ToacquirethenecessaryrightfromathirdpartywhichhaslawfulownershipoftherightsothattheLicenseewillbeabletocontinuetousetheLicensedSoftware; b) ToreplacetheLicensedSoftwarewithanalternativeonewhichavoidstheinfringement;or c) ToremodeltheLicensedSoftwaresothattheLicensedSoftwarecanavoidtheinfringementofsuchthirdparty’sright.5.4IfandwhenYokogawafailstotakeeitherofthecountermeasuresassetforthintheprecedingsubparagraphsofParagraph5.3,YokogawashallindemnifytheLicensee

onlybypayingback thepriceamountof theLicensedSoftwarewhichYokogawahas received from theLicensee.THEFOREGOINGPARAGRAPHSSTATETHEENTIRELIABILITYOFYOKOGAWAANDANYTHIRDPARTYLICENSINGTHIRDPARTYSOFTWARETOYOKOGAWAWITHRESPECTTOINFRINGEMENTOFTHEINTELLECTUALPROPERTYRIGHTSINCLUDINGBUTNOTLIMITEDTO,PATENTANDCOPYRIGHT.

Page 4: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

iiiIM 735371-01E

Article6(Liabilities)6.1IfandwhentheLicenseeshouldincuranydamagerelatingtoorarisingoutoftheLicensedSoftwareorservicethatYokogawahasprovidedtotheLicenseeunderthe

conditions herein due to a reason attributable to Yokogawa, Yokogawa shall take actions in accordance with this Agreement. However, in no event shall Yokogawa be liableor responsible foranyspecial, incidental,consequentialand/or indirectdamage,whether incontract,warranty, tort,negligence,strict liability,orotherwise,including,withoutlimitation,lossofoperationalprofitorrevenue,lossofuseoftheLicensedSoftware,oranyassociatedproductsorequipment,costofcapital,lossorcostof interruptionof theLicensee’sbusiness,substituteequipment, facilitiesorservices,downtimecosts,delays,and lossofbusiness information,orclaimsofcustomersofLicenseeorotherthirdpartiesforsuchorotherdamages.EvenifYokogawaisliableorresponsibleforthedamagesattributabletoYokogawaandtotheextentofthisArticle6,Yokogawa’sliabilityfortheLicensee’sdamageshallnotexceedthepriceamountoftheLicensedSoftwareorservicefeewhichYokogawahasreceived.PleasenotethatYokogawashallbereleasedordischargedfrompartoralloftheliabilityunderthisAgreementiftheLicenseemodifies,remodels,combineswith other software or products, or causes any deviation from the basic specifications or functional specifications, without Yokogawa’s prior written consent.

6.2AllcausesofactionagainstYokogawaarisingoutoforrelatingtothisAgreementortheperformanceorbreachhereofshallexpireunlessYokogawaisnotifiedoftheclaim within one (1) year of its occurrence.

6.3Innoevent,regardlessofcause,shallYokogawaassumeresponsibilityfororbeliableforpenaltiesorpenaltyclausesinanycontractsbetweentheLicenseeanditscustomers.

Article7(LimitofExport) UnlessotherwiseagreedbyYokogawa,theLicenseeshallnotdirectlyor indirectlyexportortransfertheLicensedSoftwaretoanycountriesotherthanthosewhere

Yokogawapermitsexportinadvance.

Article8(Term) ThisAgreementshallbecomeeffectiveonthedatewhentheLicenseereceivestheLicensedSoftwareandcontinuesineffectunlessoruntilterminatedasprovided

herein,ortheLicenseeceasesusingtheLicensedSoftwarebyitselforwithYokogawa’sthirty(30)dayspriorwrittennoticetotheLicensee.

Article9(InjunctionforUse) During the termof thisAgreement,Yokogawamay,at itsowndiscretion,demand injunctionagainst theLicensee in case thatYokogawadeems that theLicensed

Software is used improperly or under severer environments other than those where Yokogawa has first approved, or any other condition which Yokogawa may not permit.

Article 10 (Termination) Yokogawa,atitssolediscretion,mayterminatethisAgreementwithoutanynoticeorremindertotheLicenseeiftheLicenseeviolatesorfailstoperformthisAgreement.

However, Articles 5, 6, and 11 shall survive even after the termination.

Article11(Jurisdiction) Anydispute,controversies,ordifferencesbetweenthepartiesheretoastointerpretationorexecutionofthisAgreementshallberesolvedamicablythroughnegotiation

betweenthepartiesuponthebasisofmutualtrust.Shouldthepartiesfailtoagreewithinninety(90)daysafternoticefromoneofthepartiestotheother,bothpartiesherebyirrevocablysubmittotheexclusivejurisdictionoftheTokyoDistrictCourt(mainoffice)inJapanforsettlementofthedispute.

Article12(GoverningLaw) ThisAgreementshallbegovernedbyandconstruedinaccordancewiththelawsofJapan.TheLicenseeexpresslyagreestowaiveabsolutelyandirrevocablyandto

thefullestextentpermissibleunderapplicablelawanyrightsagainstthelawsofJapanwhichitmayhavepursuanttotheLicensee’slocallaw.

Article 13 (Severability) In theevent thatanyprovisionhereof isdeclaredor found tobe illegalbyanycourtor tribunalofcompetent jurisdiction,suchprovisionshallbenullandvoidwith

respecttothejurisdictionofthatcourtortribunalandalltheremainingprovisionshereofshallremaininfullforceandeffect.

Article14(ChangeinAgreement) The contents of this contract, contents of this product, specifications of the licensed software, related support and other related services can be changed at Yokogawa’s

discretion. However, if Yokogawa make the above changes, Yokogawa will notify them to the customer without delay.

Terms and Conditions of the Software License

Page 5: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

iv IM 735371-01E

Checking the Contents of the Package

Unpacktheboxandcheckthatthecontentsbelowareavailable.Ifsomeofthecontentsare not correct or missing or if there is physical damage, contact the dealer from which you purchased them.

• AQ6370ViewerInstallationManual(IM735371-02E)

• CD-ROMTheCD-ROMcontainsthefollowingitems.• AQ6360Viewer(softwareforAQ6360,includedwithCD-ROMEdition14orlater)• AQ6370Viewer(softwareforAQ6370)• AQ6370BViewer(softwareforAQ6370B,includedwithCD-ROMEdition5orlater)• AQ6370CViewer(softwareforAQ6370C,includedwithCD-ROMEdition7orlater)• AQ6370DViewer(softwareforAQ6370D,includedwithCD-ROMEdition9orlater)• AQ6373Viewer(softwareforAQ6373,includedwithCD-ROMEdition6orlater)• AQ6373BViewer(softwareforAQ6373B,includedwithCD-ROMEdition10or

later)• AQ6374Viewer(softwareforAQ6374,includedwithCD-ROMEdition13orlater)• AQ6375/AQ6375B/AQ6376Viewer(softwareforAQ6375,includedwithCD-ROM

Edition 12 or later)• OSAViewer(commonsoftware,includedwithCD-ROMEdition14orlater)• AQ6370FirmwareUpdater The updater is used when the AQ6370 firmware version is older than R02.01.• AQ6370ViewerUser’sManual(thismanual)

• Licensesheet(1) You must enter the license code indicated on the license sheet when you start the

softwareprogram.Fordetails,seesection2.1,“StartingandClosingtheSoftwareProgram.”

Page 6: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

vIM 735371-01E

SystemRequirementsandNotesonUsingtheSoftware Program

PC SystemRequirementsPCAPCrunningfollowingoperatingsystemwithatleast256MBofmemory(512MBormore recommended).

OperatingSystem• WindowsVista(32bit/64bit)(ServicePack2orlater)• Windows7(32bit/64bit)(ServicePack1orlater)• Windows8/8.1(32bit/64bit)• Windows10(32bit/64bit)

CD-ROMDriveACD-ROMdriveisrequiredtoinstallthissoftwareprogram.

EthernetinterfaceALANport(100BASE-TX)isrequiredtousetheOpticalSpectrumAnalyzerinremotecontrol mode or file transfer mode.

Display,Mouse,andPrinter• Display:1024×768pixels,65536colorsormore• Mouseandprinter:Thosecompatiblewiththeoperatingsystemsabove(theprinter

is required when printing a hard copy of the screen)

NotesonUsingtheSoftwareProgramStoringtheCD-ROMPleasestoretheoriginalCD-ROM(containingthesoftwareprogram)inasafeplace.Duringtheactualoperation,usethesoftwareprogramthatisinstalledontheharddisk.

PrecautionstoBeTakenWhenUsingtheSoftwareProgram• DonotoperatetheOpticalSpectrumAnalyzerfromthepanelwhileyouare

controlling the Optical Spectrum Analyzer using this software program. If you do, operation errors can result.

• OnlyasingleOpticalSpectrumAnalyzercanbecontrolledbythissoftwareprogram. In addition, simultaneous connection to the Optical Spectrum Analyzer frommultiplePCsisnotallowed.

• LimitationsexistsuchasintheresultoftheanalysisfunctionifawaveformfileotherthanthatoftheAQ6360/AQ6370/AQ6370B/AQ6370C/AQ6370D/AQ6373/AQ6373B/AQ6374/AQ6375/AQ6375B/AQ6376isloadedintothissoftwareprogram. For details, see page 1-5.

Page 7: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

vi IM 735371-01E

InstallingandUninstallingtheSoftwareProgram

ProcedureInstallingtheSoftware ProgramTheCD-ROMcontainsviewerscorrespondingtothevariousopticalspectrumanalyzermodels.Select the viewer you want to install from the installation tool that starts automatically. If theinstallationtooldoesnotstartautomatically,runAutorun.exeintheCD.

• ToinstallAQ6360Viewer:AQ6360Viewer• ToinstallAQ6370Viewer:AQ6370Viewer• ToinstallAQ6370BViewer:AQ6370BViewer• ToinstallAQ6370CViewer:AQ6370CViewer• ToinstallAQ6370DViewer:AQ6370DViewer• ToinstallAQ6373Viewer:AQ6373Viewer• ToinstallAQ6373BViewer:AQ6373BViewer• ToinstallAQ6374Viewer:AQ6374Viewer• ToinstallAQ6375/AQ6375B/AQ6376Viewer:AQ6375&76Viewer• ToinstallOSAViewer:OSAViewer

The procedure below is for installing the software program on Windows 7.AQ6370Viewerisusedforthisexample.Forotherviewer,substitute“AQ6360/AQ6370B/AQ6370C/AQ6370D/AQ6373/AQ6373B/AQ6375/AQ6375B/AQ6376/OSA”wherever“AQ6370”appears.

1. Start Windows and log on with administrator privileges. If AQ6370 Viewer is already installed, uninstall it first.

2. LoadthediscintotheCD-ROMdrive.The installation tool starts automatically.

3. Select AQ6370 Viewer, and then click Select. The installation begins

4. PresstheNext button.

Page 8: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

viiIM 735371-01E

InstallingandUninstallingtheSoftwareProgram

5. Read the license agreement carefully. If you agree to the terms, click the IAgree option button and then click Next.

6. Select the installation destination drive and folder, and click Next.The installation destination setup screen shown below opens.ThedefaultinstallationdestinationisC:\ProgramFiles\Yokogawa\.

7. In the installation destination confirmation screen, click Next.The software installation starts. A progress bar is shown in the screen while the installation is in progress.

Page 9: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

viii IM 735371-01E

8. ClickClose to finish the installation.Yokogawa>AQ6370ViewerisaddedtoProgramsintheStartmenuinthetaskbar,andaAQ6370 Viewer shortcut icon is created on the desktop.

Note• WhenyouruntheAQ6370Viewerforthefirsttime,alicenseconfirmationscreenopens.

ClickInputLicensecode,andenterthelicensecodeindicatedinthelicensesealtoopenthemainscreen.Fordetails,seesection2.1,“StartingandClosingtheSoftwareProgram.”

• AQ6360ViewerisincludedwithCD-ROMEdition14orlater.• AQ6370BViewerisincludedwithCD-ROMEdition5orlater.• AQ6370CViewerisincludedwithCD-ROMEdition7orlater.• AQ6370DViewerisincludedwithCD-ROMEdition9orlater.• AQ6373ViewerisincludedwithCD-ROMEdition6orlater.• AQ6373BViewerisincludedwithCD-ROMEdition10orlater.• AQ6374ViewerisincludedwithCD-ROMEdition13orlater.• AQ6375/AQ6375B/AQ6376ViewerisincludedwithCD-ROMEdition12orlater.• OSAViewerisincludedwithCD-ROMEdition14orlater.• MultipledifferentmodelsofViewerscanbeinstalledonthesamePC.

UninstallingtheSoftwareProgramThe procedure below is for uninstalling the software program on Windows 7.

1. Onthetaskbar,clicktheStartbuttonandchooseControlPanel.

2. Double-clickUninstallprogram of ProgramsfromtheControlPanel.

3. IntheProgramsandFeatureswindow,selectAQ6370Viewer,andclickUninstall.Aconfirmationdialogboxfordeletingtheprogramopens.

4. ClickYes.The software program is uninstalled.

NoteThe files that the user saved (waveform files, etc.) remain in the follwing folder even if you uninstall the software program. MyDocument\AQ6370ViewerData

InstallingandUninstallingtheSoftwareProgram

Page 10: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

ixIM 735371-01E

1

2

3

4

5

6

7

8

Index

Contents

TermsandConditionsoftheSoftwareLicense................................................................................. iiCheckingtheContentsofthePackage............................................................................................ ivSystemRequirementsandNotesonUsingtheSoftwareProgram ..................................................vInstallingandUninstallingtheSoftwareProgram ............................................................................vi

Chapter1 FunctionalOverview1.1 Operation Modes .............................................................................................................. 1-11.2 FunctionalDifferenceinOperationModesandLoadableFiles ........................................ 1-41.3 FunctionsofthePartsoftheScreen ................................................................................ 1-7

Chapter2 BasicOperations2.1 StartingandClosingtheSoftwareProgram ..................................................................... 2-12.2 BasicOperationUsingtheMouseandKeys .................................................................... 2-32.3 ConnectingandSettingtheEthernetInterfaceoftheOpticalSpectrumAnalyzer ........... 2-6

Chapter3 CommonOperationsinViewerModeandRemoteControlMode(forthemodel-specificsoftware)3.1 Main Menu ........................................................................................................................ 3-13.2 MakingaHardCopyoftheScreen .................................................................................. 3-43.3 SettingtheUserFolder .................................................................................................... 3-5

Chapter4 OperationsinViewerMode(forthemodel-specificsoftware)4.1 LoadingWaveformDataandDisplayingWaveforms ....................................................... 4-14.2 SavingtheSetupData ..................................................................................................... 4-44.3 SoftKeyMenuinViewerMode ........................................................................................ 4-84.4 CommandsThatDoNotOperateintheProgramFunction ............................................. 4-9

Chapter5 OperationsinRemoteControlMode(forthemodel-specificsoftware)5.1 ConnectandDisconnectOperations ................................................................................ 5-15.2 PrecautionstoBeTakenWhenOperatinginRemoteControlMode ............................... 5-35.3 SoftKeyMenuinRemoteControlMode .......................................................................... 5-4

Chapter6 FileTransfer6.1 File Transfer Operation ..................................................................................................... 6-1

Chapter7 OperationoftheCommonSoftware7.1 StarttheCommonSoftware ............................................................................................. 7-17.2 OperationsontheViewerSoftware(Commonsoftware) ................................................. 7-27.3 OperationsontheRemoteControlSoftware(Commonsoftware) ................................... 7-4

Chapter8 Troubleshooting8.1 Troubleshooting ................................................................................................................ 8-18.2 MessagesandCorrectiveActions .................................................................................... 8-3

Index

Page 11: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-1IM 735371-01E

Functional Overview

1

2

3

4

5

6

7

8

Index

1.1 OperationModes

Model-specificSoftwareandCommonSoftwareThis software product contains two types of software:• Model-specificsoftware• Commonsoftware(OSAViewer)

Model-SpecificSoftwareThe model-specific software has the following three operation modes.TherelationshipbetweenthesemodeswillbeexplainedusingtheAQ6370Viewerwindowasanexample.AnAQ6370Viewerscreenisusedforthisexample.The software application has the three operation modes listed below.The program starts in Viewer mode.ThemodeswitchestoRemoteControlifyouconnecttotheOpticalSpectrumAnalyzer.Select FileTransfer in the main menu to switch to File Transfer mode.

Start the program

Viewer mode Remote Control mode

Connect to the Optical Spectrum Analyzer

Disconnect

File Transfer modeConnect to the Optical Spectrum Analyzer

Disconnect

File Transfer menuSelect

File TransferwindowExit

ViewerModeTheOpticalSpectrumAnalyzerdisplayisshownonthePCdisplay.Youcanusethemouse and keyboard to operate the display in the same manner as with the Optical Spectrum Analyzer.You can carry out the following operations in Viewer mode.• LoadthewaveformdatathatwassavedontheAQ6360/AQ6370/AQ6370B/AQ6370C/

AQ6370D/AQ6373/AQ6373B/AQ6374/AQ6375/AQ6375B/AQ6376totheUSBstoragedevice and display the waveform in the screen.

WaveformdatasavedontheAQ6317orAQ6319canalsobeloaded.• Performmarkeroperationsandanalysisonthedisplayedwaveformanddisplaythe

result.• Createandeditprogramsandtemplatedata.• Savethecreateddatatoafile.

AQ6370 OPTICAL SPECTRUM ANALYZER

USB

POWER

FUNCTION DATA ENTRY

CENTER

SWEEP

SPAN LEVEL

ZOOM

SETUP

MARKER

DISPLAY

PEAK SEARCH

TRACE

ANALYSIS

USER MEMORY FILE

SYSTEM ADVANCE PROGRAM

OREMOTE

UNDO/ LOCAL HELP COPY FEED

COARSE

7 8 9

4 5 6

1 2 3

0 . -

BACK SPASE

nm/ ENTER

m/ ENTER

OPTICAL INPUT (600 1700nm)

CALIBRATION OUTPUT

USB storage device

PCOptical Spectrum Analyzer

Chapter1 FunctionalOverview

Page 12: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-2 IM 735371-01E

DisplayExamples

RemoteControlModeThe same display as the display on the Optical Spectrum Analyzer connected via the EthernetinterfaceisshownonthePCdisplay.Youcanusethemouseandkeyboardtooperate the display in the same manner as with the Optical Spectrum Analyzer unit.YoucancarryoutthefollowingoperationsinRemoteControlmode.• SetthemeasurementconditionsonthetargetOpticalSpectrumAnalyzerandexecute

measurements.• DisplaythewaveformdatathatismeasuredontheOpticalSpectrumAnalyzeronthe

PCdisplay.• Performmarkeroperationsandanalysisonthedisplayedwaveformanddisplaythe

result.

AQ6370 OPTICAL SPECTRUM ANALYZER

USB

POWER

FUNCTION DATA ENTRY

CENTER

SWEEP

SPAN LEVEL

ZOOM

SETUP

MARKER

DISPLAY

PEAK SEARCH

TRACE

ANALYSIS

USER MEMORY FILE

SYSTEM ADVANCE PROGRAM

OREMOTE

UNDO/ LOCAL HELP COPY FEED

COARSE

7 8 9

4 5 6

1 2 3

0 . -

BACK SPASE

nm/ ENTER

m/ ENTER

OPTICAL INPUT (600 1700nm)

CALIBRATION OUTPUT

PC Optical Spectrum Analyzer

Ethernet

Control commandWaveform data

DisplayExamples

NoteThewaveformdatathatcanbeloadedinRemoteControlmodeisthedatastoredonthePCin which this software program is installed. In addition, waveform data can be saved in Remote ControlmodeonlytothePCinwhichthissoftwareprogramisinstalled.

1.1OperationModes

Page 13: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-3IM 735371-01E

Functional Overview

1

2

3

4

5

6

7

8

Index

FileTransferModeFiles that are stored in the Optical Spectrum Analyzer can be transferred at high speeds tothePCviatheEthernetinterface.FilesalsobetransferredfromthePCtotheOpticalSpectrum Analyzer.

AQ6370 OPTICAL SPECTRUM ANALYZER

USB

POWER

FUNCTION DATA ENTRY

CENTER

SWEEP

SPAN LEVEL

ZOOM

SETUP

MARKER

DISPLAY

PEAK SEARCH

TRACE

ANALYSIS

USER MEMORY FILE

SYSTEM ADVANCE PROGRAM

OREMOTE

UNDO/ LOCAL HELP COPY FEED

COARSE

7 8 9

4 5 6

1 2 3

0 . -

BACK SPASE

nm/ ENTER

m/ ENTER

OPTICAL INPUT (600 1700nm)

CALIBRATION OUTPUT

PC Optical Spectrum Analyzer

EthernetHigh speed file transfer

DisplayExamples

CommonSoftware(OSAViewer)When you start OSA Viewer, the top menu appears. For this top menu, you can start varioussoftwareapplicationssuchasViewer,RemoteControl,andFileTransfer.These applications provide functions that are nearly equivalent as the Viewer, Remote Control,andFileTransfermodesofthemodel-specificsoftware.

Displays the data save destination folder (user folder)

Displays the version and license information of this softwar

Displays the user’ s manual

Starts the Remote Control software

Starts the Viewer software of each model

Starts the File Transfer software

OSAViewersupportstheAQ6360Series(AQ6360),AQ6370Series(AQ6370D/AQ6370C),AQ6373Series(AQ6373/AQ6373B),AQ6375Series(AQ6375/AQ6375B),AQ6373Series(AQ6374),andAQ6376Series(AQ6376).ItdoesnotsupporttheAQ6370orAQ6370B.

1.1OperationModes

Page 14: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-4 IM 735371-01E

1.2 FunctionalDifferenceinOperationModesandLoadableFiles

FunctionalDifferencesinOperationModesThefunctionsthatyoucanexecutevarydependingontheoperationmodeasfollows:• ViewerMode Almostallthefunctionsexceptthesweepfunctioncanbeexecuted.Somecommands

donotoperateintheexecutionoftheprogramfunction.• RemoteControlMode Almostallthefunctionsexcepttheprogramfunctioncanbeexecuted.However,the

waveform displayed on the Optical Spectrum Analyzer and the waveform displayed on thePCdisplaymaynotmatchduringremotecontrol.

• FileTransferMode OnlyfiletransferbetweentheOpticalSpectrumAnalyzerandthePCispossible.

MainOperationDifferencesinViewerandRemoteControlModesFordetails,seesection4.3,“SoftKeyMenuinViewerMode”andsection5.3,“SoftKeyMenuinRemoteControlMode.”

FrontPanelKeyMenu

Viewer Mode

RemoteControlMode Note

CENTER Yes YesSPAN Yes YesLEVEL Yes Yes

SWEEP No Yes AUTO,REPEAT,SINGLE,STOP,andSEGMENTMEASUREcannotbeusedinViewer mode.

ZOOM Yes Limit WaveformmagnificationandreductioncanbecarriedoutonlyonthePCinRemoteControlmode.

SETUP Yes Yes

TRACE Yes Limit WaveformdoesnotmatchbetweentheOpticalSpectrumAnalyzerandPCwhenusingROLLAVG,MAXHOLD,orMINHOLDinRemoteControlmode.

DISPLAY Limit LimitDISPLAYOFFcannotbeusedinViewermode.Waveform does not match betweentheOpticalSpectrumAnalyzerandPCwhenusingNOISEMASKoperationinRemoteControlmode.

MARKER Yes Limit MarkerfunctioncanonlybeusedonthePCinRemoteControlmode(linemarkers 1 and 2 can be used on the Optical Spectrum Analyzer).

PEAKSEARCH Yes Limit ThesearchmodesettingandmultisearchfunctioncanonlybeexecutedonthePCinRemoteControlmode.

ANALYSIS Yes Limit TheanalysisfunctioncanonlybeexecutedonthePCinRemoteControlmode.USER Yes YesMEMORY Yes YesFILE Yes Yes

PROGRAM Limit Limit EditingisallowedonlyonthePC.SomecommandscannotbeexecutedinViewermode.ProgramscannotbeexecutedinRemoteControlmode.

ADVANCE Limit LimitDATALOGGING>STARTcannotbeusedinViewermode.DATALOGGINGcannotbeusedinRemoteControlmode.TemplateeditingandexecutionareallowedonthePCinRemoteControlmode.

SYSTEM Limit Limit

OPTICALALIGNMENT,WLCALIBRATION,SYSTEMINFORMATION,andRESBWCALIBRATIONcannotbeperformedinViewermode.TheprogressofOPTICALALIGNMENT,WLCALIBRATION,andRESBWCALIBRATIONisnotdisplayedinRemoteControlmode.

UNDO/LOCAL No YesCOPY Yes YesFEED No No AQ6370,AQ6370B,AQ6370C,AQ6375,AQ6373PRESET Yes Yes ExcludesaboveHELP Yes Yes

Yes:Available,No:Notavailable,Limit:Withlimitation.

Page 15: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-5IM 735371-01E

Functional Overview

1

2

3

4

5

6

7

8

Index

LoadableFilesInViewerorRemoteControlmode,thefileslistedbelowthathavebeenstoredontheAQ6360,AQ6370,AQ6370B,AQ6370C,AQ6370D,AQ6373,AQ6373B,AQ6375,AQ6375B,AQ6376,AQ6317,orAQ6319canbeloaded.Theextensionsoftheloadabledata are given in parentheses.AQ6360 Viewer• Waveformdata(.csv,wva,wx9,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wva,wx9,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.sta,.st9,.st8,.st7,.st6,.st5,and.st4)• Programdata(.pga,.pg9,.pg8,.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dta,.dt9,.dt8,.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)

AQ6370 Viewer• Waveformdata(.csv,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wv6,.wv5,.wv4,and.txt)• Setupdata(.st6,.st5,and.st4)• Programdata(.pg6,.pg5,and.pg4)• Analysisresultdata(.dt6,.dt5,.dt4,and.csv)• Template data (.csv)

AQ6370BViewer• Waveformdata(.csv,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.st8,.st7,.st6,.st5,and.st4)• Programdata(.pg8,.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dt8,.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)

AQ6370CViewerandAQ6370DViewer• Waveformdata(.csv,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.st8,.st7,.st6,.st5,and.st4)• Programdata(.pg8,.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dt8,.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)• Loggingdata(.lg8)

AQ6373 Viewer• Waveformdata(.csv,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.st9,.st8,.st7,.st6,.st5,and.st4)• Programdata(.pg9,.pg8,.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dt9,.dt8,.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)

AQ6373BViewer• Waveformdata(.csv,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.st9,.st8,.st7,.st6,.st5,and.st4)• Programdata(.pg9,.pg8,.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dt9,.dt8,.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)• Loggingdata(.lg9,.lg8)

1.2FunctionalDifferenceinOperationModesandLoadableFiles

Page 16: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-6 IM 735371-01E

AQ6374 Viewer• Waveformdata(.csv,.wx9,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wx9,.wv9,.wv8,wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.sx9,.st9,.st8,.st7,.st6,.st5,and.st4)• Programdata(.pg9,.pg8,.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dt9,.dt8,.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)• Loggingdata(.lx9,.lg9,.lg8)

AQ6375/AQ6375B/AQ6376Viewer• Waveformdata(.csv,.wv7,.wv6,.wv5,.wv4,and.txt)• Memorydata(.csv,.wv7,.wv6,.wv5,.wv4,and.txt)• Setupdata(.st7,.st6,.st5,and.st4)• Programdata(.pg7,.pg6,.pg5,and.pg4)• Analysisresultdata(.dt7,.dt6,.dt5,.dt4,and.csv)• Template data (.csv)

Note• IfAQ6317orAQ6319dataareloaded,somefunctionscannotbeexecuted.• ToanalyzewaveformdatafromtheAQ6360,AQ6370,AQ6370B,AQ6370C,AQ6370D,

AQ6373,AQ6373B,AQ6374,AQ6375,AQ6375BorAQ6376usethemodel’scorrespondingViewer.

Otherwise, the following analysis results and the displayed contents cannot be guaranteed. (includingAQ6317orAQ6319waveformdata)

Poweranalysis,LEDanalysis,WDManalysis,OSNR(WDM)analysis,EDFA-NFanalysis,andswitchingoftheverticalaxisunittodBm/nm

ConnectableAQ6370sandFirmwareUpdateMain unit firmware updates are sometimes required with the AQ6370. WiththeAQ6360/AQ6370B/AQ6370C/AQ6370D/AQ6373/AQ6373B/AQ6374/AQ6375/AQ6375B/AQ6376,updatesarenotrequired.Connectioncanbemaderegardlessoftheversion.

AQ6370srequiredupdatesIf the firmware version is older than R02.01, update the firmware using the AQ6370 FirmwareUpdaterintheUPDATEfolder(\UPDATEFILE\AQ6370)ontheaccompanyingCD-ROM.TheAQ6370sthatcanbeconnectedinRemoteControlmodeandFileTransfermodeare those with firmware version R02.01 or later.

CheckingtheFirmwareVersion1. PressSYSTEM on the AQ6370.

2. PresstheMOREsoftkeytodisplayMORE4/4.

3. PresstheVERSION soft key.

UpdateProcedure1. InserttheaccompanyingCD-ROMandaUSBmemoryintothePC.

2. CopytheUPDATEfolderontheCD-ROMtotheUSBmemory.

3. InserttheUSBmemoryintotheAQ6370.

4. Updatethefirmwareaccordingtotheproceduregiveninsection10.1,“UpgradingtheFirmware”intheAQ6370OpticalSpectrumAnalyzerUser’sManual(IM735301-01E).

NoteIf the firmware version of the AQ6370 is already R02.01 or later, do not update the firmware.

1.2FunctionalDifferenceinOperationModesandLoadableFiles

Page 17: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-7IM 735371-01E

Functional Overview

1

2

3

4

5

6

7

8

Index

1.3 FunctionsofthePartsoftheScreen

The figure below shows the screen in Viewer mode.The same screen as that of the actual instrument is displayed. AnAQ6370Viewerscreenisusedforthisexample.

1

2

3

4

5

6

7 8 9 10 11 12 13

15 17

18

19

20

21

22

14 16

23 24

25

No. Function1 Dataarea2 Measurement condition area3 Displays when the measurement conditions are changed.4 Displaysthelevelaxisscaleperdivision

5 Displays when the settings for span, the number of sampling points, and the resolution are inappropriate.

6 Displaysthereferencelevel7 Labelarea(upto56characters)8 Displaystheresolution9 Displaysthemeasurementsensitivity10 Displaystheaveragecount11 Displaysthenumberofsamples12 Displaystheyear,month,date,andhour13 Displaysthestatusofeachtrace.14 Displays when using the ZOOM function

Page 18: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-8 IM 735371-01E

15 Displaysthetypicalsetupstatus IfasettingisturnedON,thebuttonisshowndepressed.Ifthescreenisblack

and white, it is shown in black. TLSSYC ........ON/OFFsettingofTLSSNCSWEEP(NotdisplayedwhenusingAQ6373

Viewer) CORSIZ ........SMALL/LARGEsettingofFIBERCORESIZE(Onlydisplayedwhenusing

AQ6373 Viewer) RESCOR ......ON/OFFsettingofRESOLNCORRECT LVLSHF .........ON/OFFsettingofLEVELSHIFT WF SHF .........ON/OFFsettingofWFSHIFT NOIMSK .......NOISEMASKsetting SRCZOM ......ON/OFFsettingofSEARCH/ANAZOOMAREA SRC1-2 .........ON/OFFsettingofSEARCH/ANAL1-L2 VACWL .........MEASWLsetting AUTOFS .......ON/OFFsettingofAUTOOFFSET AUTANA .......ON/OFFsettingofAUTOANALYSIS AUTSRC .......ON/OFFsettingofAUTOSEARCH AUTSCL .......ON/OFFsettingofAUTOSUBSCALE AUTREF .......ON/OFFsettingofAUTOREFLEVEL AUTCTR .......ON/OFFsettingofAUTOCENTER SWPINT ........ON/OFFsettingofSWEEPINTERVAL (NotdisplayedwhenusingAQ6373

Viewer) SWP1-2 ........ON/OFFsettingofSWEEPMKRL1-L2 SMO OTH ......ON/OFFsettingofSMOOTHING (Only displayed when using AQ6373

Viewer) RPT ................REPEAT (repeat sweep) SGL ...............SINGLE(singlesweep) SPT ................STOP(sweepstop)

16 Displaysthewavelengthaxisscaleperdivision17 Displaysthesweepstatus RPT=Repeat,SGL=Single,andSTP=Stop18 Displaysthesoftkeymenu19 Parametervaluedisplayarea20 Parametervalueinputarea21 OVERVIEW display screen DisplayedonlywhenusingtheZOOMfunction.22 Displaysthesubscale23 Main menu The main menu is different between the model-specific software and the common

software. Model-specificsoftware Foradetaileddescriptionofthemainmenu,seesection3.1,“MainMenu.”

File .................Select to output a hard copy of the screen or when closing the software program. Connect .........Select to connect to the optical spectrum analyzer. Disconnect .....Select to disconnect the optical spectrum analyzer. File Transfer ...Select to transfer files with the optical spectrum analyzer. Setting ............Select to set the folder for saving the loaded data. Display ............Select to display the model that measured the waveform data and the actual

waveformresolution(AQ6375/AQ6375B/AQ6376Vieweronly) About .............Select to check the software version. Common software Fordetailsonthemainmenu,seesection7.1,“MainMenu.”

Open File: ......Select this to select the waveform data to be displayed. Save Screen: .Select this to save the displayed screen as image data. Print: ..............Select this to print a hard copy of the screen. Folder Setting: ....Select this to set the folder displayed on the Viewer’s File menu. TraceList: ......Select this to display information about the displayed trace. Actual Resolution Table: ...Select this to display the horizontal resolution of the viewer.

1.3FunctionsofthePartsoftheScreen

Page 19: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

1-9IM 735371-01E

Functional Overview

1

2

3

4

5

6

7

8

Index

24 Front panel key menu A menu that is shown when you right-click the mouse. The menu is equivalent to

the front panel keys of the optical spectrum analyzer.25 StatusBar

Connection destination status (CONNECT or DISCONNECT)Data transmission/reception indicator(Turns green when a command or data is transmitted or received)

Computer name or IP address of the destination optical spectrum analyzer

Port number of the destination optical spectrum analyzer

1.3FunctionsofthePartsoftheScreen

Page 20: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-1IM 735371-01E

Basic O

perations

1

2

3

4

5

6

7

8

Index

2.1 StartingandClosingtheSoftwareProgram

ProcedureAnAQ6370Viewerscreenisusedforthisexample.

Starting the SoftwareofEachModelOn the task bar, click the Start button, point to Programs > Yokogawa > AQ6370 Viewer (AQ6360Viewer/AQ6370BViewer/AQ6370CViewer/AQ6370DViewer/AQ6373Viewer/AQ6373BViewer/AQ6374Viewer/AQ6375&76Viewer) or double-click the AQ6370 Viewer/AQ6360Viewer/AQ6370BViewer/AQ6370CViewer/AQ6370DViewer/AQ6373Viewer/AQ6373BViewer/AQ6374Viewer/AQ6375&76Viewershortcuticon.When the program starts, the main windows shown below opens. The window shows the contents of the window that was shown when the program was closed the last time.

• LicenseAuthentication Whentheprogramisstartedforthefirsttime,alicenseauthenticationdialogbox

opens as shown below.

IntheLicenseMessagedialogbox,clickInputLicenseCode.IntheInputLicenseCodedialogboxthatopens,typetheusername,organization(optional),andlicensecode. ThelicensecodeisindicatedontheaccompanyingCDcaseorthelicensesheet.

Chapter2 BasicOperations

Page 21: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-2 IM 735371-01E

Whenthelicenseisauthenticated,themessagebelowappears.ClickOK to show the main window.

NoteIf the license code is not correct, an error message appears. If this happens, click OK and retypethelicensecodeagainintheInputLicenseCodedialogbox.

ExitingtheSoftwareOn the File menu, choose Exit.

StartingtheCommonSoftware(OSAViewer)OntheWindowsstartmenu,clickPrograms>Yokogawa>OSAViewer,ordouble-clickthe OSA Viewer icon on the desktop.A navigation window appears.

Displays the data save destination folder (user folder)

Displays the version and license information of this softwar

Displays the user’ s manual

Starts the Remote Control software

Starts the Viewer software of each model

Starts the File Transfer software

When you start the viewer software, a license authentication window appears, as with themodel-specificsoftware.Proceedinthesamemanneraswiththemodel-specificsoftware.For instructions on how to use the common software, see chapter 7.

ExitingtheSoftwareClickXintheupperrightofthewindow.

2.1StartingandClosingtheSoftwareProgram

Page 22: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-3IM 735371-01E

Basic O

perations

1

2

3

4

5

6

7

8

Index

2.2 BasicOperationUsingtheMouseandKeys

MouseOperationDisplayingtheFrontPanelKeyMenuRight-click in the window. The front panel key names in the FUNCTIONsectionoftheOptical Spectrum Analyzer appear.

CENTER

*PRESETontheAQ6360Viewer,AQ6370DViewer,theAQ6373BViewer,AQ6374Viewer,andtheAQ6375&76Viewer

SPANLEVELSWEEPZOOMSETUPTRACEDISPLAYMARKERPEAKSEARCHANALYSISUSERMEMORYFILEPROGRAMADVANCESYSTEMUNDO/LOCALCOPYFEED*HELP

ChoosingaMenuCommandandClosingtheFrontPanelKeyMenuLeft-clickthedesiredmenucommandtoswitchtothecorrespondingsoftkeymenu.Ifyouchooseamenucommand,thefrontpanelkeymenuclears.Clickingoutsidethefrontpanel key menu also closes the menu.

ChoosingaSoftKeyandOperatingtheParameterValueDisplay/InputAreaLeft-clickthedesiredsoftkeymenucommand.Ifyouchooseasoftkeythatrequiresyoutoenteravalue,aparameterdisplay/inputarea appears.You can change the parameter value by clicking the keys in the input area as described below.

Setting display area

Switch between fine and coarse setting of the value increased or decreased using the key BackspaceEnter the input value

Increase or decrease the input value

Input value display area

Note• Ifthevalueenteredusingthenumerickeysdonotmatchwithallowablevalues,itissetto

the closest allowable value.• IfyouclicktheBSkeyrepeatedlyandtheinputvaluedisplayareabecomesempty,theinput

value area clears, and the screen returns to the condition before you started entering the values.

• IfyouwanttosetOFFonaparameterthatcanbesettoOFF,holddownthe key.

Page 23: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-4 IM 735371-01E

KeyboardOperationYoucanalsousethePCkeyboardtocarryoutoperationsaswiththemouse.Forthemappingofthepanelkeystothekeyboard,seethePanelKeyMappingTablebelow.In addition, you can directly enter labels, file names, values, and the like from the keyboard.

PanelKeyMappingTableGroup FunctionName Keyboard Description

Setting or executionof each function

Sweep SWEEP [SHIFT]+[F1] Execute/Startthesweep.

Measurement condition settings

CENTER [SHIFT]+[F2] Set the measurement center wavelength.

SPAN [SHIFT]+[F3] Set the measurement span.LEVEL [SHIFT]+[F4] Setthelevelaxis.SETUP [SHIFT]+[F5] Set the resolution, sensitivity, etc.

Displaycondition settings

TRACE [SHIFT]+[F6] Set the trace.ZOOM [SHIFT]+[F7] Set the display scale.DISPLAY [SHIFT]+[F8] Set the screen display.

AnalysisMARKER [SHIFT]+[F9] Set the marker.SEARCH [SHIFT]+[F10] Peak/bottomsearchfunctionANALYSIS [SHIFT]+[F11] Set the analysis function.

Miscellaneous

USER [ALT]+[F1] User-definedmenuMEMORY [ALT]+[F2] Memory

FILE [ALT]+[F3] Save to file, load from file, and other file operations.

PROGRAM [ALT]+[F4] Programfunction.ADVANCE [ALT]+[F5] ExpansionfunctionSYSTEM [ALT]+[F6] Set the system.

Soft keys F1toF9 F1toF9 Varies depending on the menu.

Auxiliarykeys

UNDO/LOCAL [ALT]+[F9] Undofunction.COPY [ALT]+[F10] Screen copy.

HELP [ALT]+[F12] Displayhelp(UNDO/LOCALkeyto close help)

Parametervalueinput

Numerickeys 0123456789.- Enter values.BACKSPACE BackSpace Backspace.µm/ENTER None Enter the input.nm/ENTER ENTER Enter the input.Rotary knob [→]and[←] Changethevalueorparameter.

Arrowkeys(▲▼) [↑]and[↓]Changethevaluestep-wise,change the parameter, and scroll the table.

COARSE [ALT]+[N] Switch between fine and coarse setting of the encoder.

2.2BasicOperationUsingtheMouseandKeys

Page 24: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-5IM 735371-01E

Basic O

perations

1

2

3

4

5

6

7

8

Index

SoftKeyMenuShapesandFunctionsThe soft key menu comes in different shapes to indicate its functionality.

A normal soft key.Press to immediately execute the function.

Displays a separate window.Press the soft key to display a separate window for entering a parameter value.

Displays the next hierarchy and a separate window.Press the soft key to move to the next hierarchy and display a separate window.

Soft key to return to the previous hierarchy.Press the soft key to return to the soft keys of the previous hierarchy.

There is a next level.Indicates that the related information of the displayed item is at the next level. Press to display the soft keys of the next level. Press when this key is at the bottom of the menu to switch the entire menu.

Selection soft key.Select any of the soft keys connected with a black bar. The selected soft key is highlighted. Several soft keys may be connected.

NoteThe shapes shown on the last menu command (see below) are not soft keys. They indicate a front panel key name or the soft key menu hierarchy.

LE VEL

LEVEL

Y SCALE SETTING Indicates the soft key menu hierarchy.

This indicates that the soft key menu is under the Y SCALE SETTING hierarchy.

2.2BasicOperationUsingtheMouseandKeys

Page 25: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-6 IM 735371-01E

2.3 ConnectingandSettingtheEthernetInterfaceoftheOpticalSpectrumAnalyzer

ConnectionProcedureConnectaUTP(UnshieldedTwisted-Pair)cableoranSTP(ShieldedTwisted-Pair)cablethatisconnectedtoahub,forexample,tothe100BASE-TXportontherearpaneloftheOptical Spectrum Analyzer.

AQ6370C example

PrecautionstoBeTakenWhenConnectingtheCable• BesuretouseastraightcableviaahubfortheconnectionbetweentheOptical

SpectrumAnalyzerandthePC.• IfyouareusingaUTPcable(straightcable),useacableofcategory5.

SettingtheEthernetInterfaceIfyouareusingRemoteControlmodeorFileTransfermode,settheEthernetinterfaceof the Optical Spectrum Analyzer according to the following procedure.AnAQ6370screenisusedforthisexample.

ProcedureSelectingtheCommunicationInterface1. PressSYSTEM.

The system setup menu appears.

2. PresstheMORE1/4 soft key.The communication interface setup menu appears.

3. PresstheREMOTEINTERFACE soft key.A menu for selecting the interface appears.

4. PresstheETHERNET soft key to set the communication interface to Ethernet.

Page 26: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-7IM 735371-01E

Basic O

perations

1

2

3

4

5

6

7

8

Index

SettingtheTCP/IPParameters5. PresstheNETWORKSETTING soft key.

The Ethernet setup menu appears.

6. PresstheTCP/IPSETTING soft key.TheTCP/IPsetupmenuappears.

7. Pressthe< and >softkeystoselectAUTO(DHCP)orMANUAL.

8. PresstheSELECT soft key.• Acheckisplacedbytheselecteditem.• IfyouselectAUTO,proceedtostep10.

9. IfyouselectMANUAL,settheIPaddress,subnetmask,anddefaultgateway.Pressthe<, >, < , and < soft keys to select the input position, and press ENTER.

10. Enter the value using the rotaryknob or arrow keys, and press ENTER.

11. After entering all the settings, press the DONE soft key.

Setting the RemotePortNumber12. PresstheREMOTEPORTNO. soft key.

The port number setup screen appears.

13. Enter the port number using the rotaryknob or arrow keys, and pressENTER.

Check that this is set to AQ6370.

Set the remote port number

Setting the UserAccountInformation14. PresstheUSERACCOUNT soft key.

The user account information setup screen appears.

15. Set the user name and password used to authenticate the remote connection.

Set the password

Set the user name

2.3ConnectingandSettingtheEthernetInterfaceoftheAQ6370

Page 27: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

2-8 IM 735371-01E

ExplanationSettingtheTCP/IPParametersTheIPaddressoftheOpticalSpectrumAnalyzermustbesetcorrectlytousethisfunction correctly.IfaDHCPserverisavailableonthenetworktowhichtheOpticalSpectrumAnalyzerisconnected,theIPaddressisautomaticallyassigned.Inthiscase,set[SYSTEM]<NETWORKSETTING><TCP/IPSETTING>IPADDRESSSETTINGtoAUTO.For details on the network to which the Optical Spectrum Analyzer is connected, consult your network administrator.

SettingtheREMOTEPORTNO.Set the port number used to perform remote control from the software program. The default value is 10001.

ConnectionTheOpticalSpectrumAnalyzercanconnecttoasinglecontroller(externalPC,etc.).Ifaconnection request is received from a controller when the Optical Spectrum Analyzer is already connected, the current connection is maintained.

ComputerNameThe computer name of the Optical Spectrum Analyzer is as follows: AQ6360: “AQ6360@@@@@@@@@” AQ6370: “AQ6370@@@@@@@@@” AQ6370B: “6370B@@@@@@@@@” AQ6370C:“6370C@@@@@@@@@” AQ6370D:“6370D@@@@@@@@@” AQ6373: “6373@@@@@@@@@” AQ6373B: “6373B@@@@@@@@@” AQ6374: “6374@@@@@@@@@” AQ6375: “AQ6375@@@@@@@@@” AQ6375B: “6375B@@@@@@@@@” AQ6376: “6376@@@@@@@@@”Where@@@@@@@@@istheserialnumber.Theserialnumberisindicatedbynine alphanumeric characters on the rear panel of the Optical Spectrum Analyzer. The computer name cannot be changed.

Setting the UserAccountThe software program performs authentication using the user name and password when making a remote connection to the Optical Spectrum Analyzer.ThesoftwareprogramandtheOpticalSpectrumAnalyzerusetheMD5algorithm(RSADataSecurity,Inc.MD5MessageDigestAlgorithm)forthepasswordauthentication.The default user name is anonymous. When using this user name, the authentication password is not necessary.

2.3ConnectingandSettingtheEthernetInterfaceoftheAQ6370

Page 28: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

3-1IM 735371-01E

Com

mon O

perations in Viewer M

ode and Rem

ote Control M

ode (for the model-specific softw

are)

1

2

3

4

5

6

7

8

Index

3.1 MainMenu

Thissectionexplainshowtousethemainmenuofthemodel-specificsoftwareusingtheAQ6370Viewerwindowasanexample.

FileMenuPrintChoosethiscommandtooutputahardcopyofthescreentoaprinterconnectedtothePC.Fortheoperatingprocedure,seesection3.2,“MakingaHardCopyoftheScreen.”

ExitChoosethiscommandtoclosetheprogram.

ConnectMenuChoosethismenutoconnecttotheOpticalSpectrumAnalyzerviatheEthernetinterface.Whenconnected,theoperationmodeswitchestoRemoteControlmode.Fortheoperatingprocedure,seesection5.1,“ConnectandDisconnectOperations.”

DisconnectMenuChoosethismenutostoptheconnectiontotheOpticalSpectrumAnalyzer.Whenyouselectthemenu,thedialogboxshownbelowappears.ClickOKtostoptheconnection and switch back to Viewer mode.Fortheoperatingprocedure,seesection5.1,“ConnectandDisconnectOperations.”

Chapter3 CommonOperationsinViewerModeandRemoteControlMode(forthemodel-specificsoftware)

Page 29: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

3-2 IM 735371-01E

FileTransferMenuChoosethismenutotransferthedatastoredontheOpticalSpectrumAnalyzertothePC.Fortheoperatingprocedure,seesection6.1,“FileTransferOperation.”

SettingMenuFolderSettingChoosethiscommandtochangethefolder(userfolder)onthePCforsavingthefileloadedinViewerorRemoteControlmodeorthedrivetowhichtheUSBstoragedeviceisconnected.Bydefault,thefolderinwhichthisprogramisstoredistheuserfolder. Fortheoperatingprocedure,seesection3.3,“SettingtheUserFolder.”

3.1MainMenu

Page 30: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

3-3IM 735371-01E

Com

mon O

perations in Viewer M

ode and Rem

ote Control M

ode (for the model-specific softw

are)

1

2

3

4

5

6

7

8

Index

DisplayMenuTraceList(forAQ6360,AQ6374,AQ6375,AQ6375BandAQ6376)Liststheopticalspectrumanalyzermodelsthatmeasuredthewaveformdataofeachtrace.

Displays optical spectrum analyzer models

Actualresolutiontable(forAQ6375,AQ6375BandAQ6376)Liststheactualresolutions(typicalvalues)determinedfromthecenterwavelengthsofopticalspectrumanalyzermodels(AQ6375/AQ6375B/AQ6376)foreachresolutionsetting.

Resolution settings

Select the unit.

Set the center value (wavelength, frequency, wavenumber)

Actual resolutions (typical values)

AboutMenuChoosethismenutocheckthesoftwareversion.

Software version

Main unit's firmware version corresponding to the analysis results of this software(AQ6376 firmware version in the case of the AQ6375&76 Viewer)

Note• TheversionRxx.xx(wherexxarenumbers)shownwhenyouchoosetheAboutmenu

corresponds to the firmware version. If the Optical Spectrum Analyzer firmware version does not match the version shown here, the analysis results of this program may not match the those of the Optical Spectrum Analyzer.

• ThesoftwareversionshownwhenyouchooseSYSTEM>VERSIONinRemoteControlmode is the Optical Spectrum Analyzer firmware version.

3.1MainMenu

Page 31: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

3-4 IM 735371-01E

3.2 MakingaHardCopyoftheScreen

You can print the displayed screen by carrying out the procedure below.

Procedure1. On the File menu, choose Print.

The print setup window opens.

2. Set the printer, the number of copies, and the like, and click Print.

Page 32: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

3-5IM 735371-01E

Com

mon O

perations in Viewer M

ode and Rem

ote Control M

ode (for the model-specific softw

are)

1

2

3

4

5

6

7

8

Index

3.3 SettingtheUserFolder

YoucanchangetheuserfolderforsavingthefileloadedinViewerorRemoteControlmode(orthedrivetowhichtheUSBstoragedeviceisconnected)bycarryingouttheprocedure below.

Procedure1. On the Setting menu, choose UserFolderSetting.

The folder setup window opens.

Select the load source folder when the user data file load source is set to INT

Select the USB storage drive when the user data file load source is set to EXT

2. Select the folder or drive, and click OK.

Page 33: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-1IM 735371-01E

Operations in View

er Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

4.1 LoadingWaveformDataandDisplayingWaveforms

You can load the waveform data and display the data on the screen by carrying out the procedurebelow.AnAQ6370Viewerscreenisusedforthisexample.

ProcedurePreparingtheWaveformData

1. CopythewaveformdatafileyouwanttoloadfromtheUSBstoragemediumtothe user folder.• Fortheproceduretosettheuserfolder,seesection3.3,“SettingtheUserfolder.”• FortheproceduretosavethewaveformdatatotheUSBstoragemedium,seesection8.3,

“Saving/LoadingDisplayedData”intheOptical Spectrum Analyzer User’s Manual.• ToloadthewaveformdatafilestoredontheUSBstoragemedium,inserttheUSB

storagemediumintothePC.

LoadingtheWaveformData2. On the task bar, click the Start button, point to Programs > Yokogawa > AQ6370

Viewer (AQ6360Viewer/AQ6370BViewer/AQ6370CViewer/AQ6370DViewer/AQ6373Viewer/AQ6373BViewer/AQ6374Viewer/AQ6375&76Viewer) to start the program.

You can also double-click the shortcut icon on the desktop.

Chapter4 OperationsinViewerMode(forthemodel-specificsoftware)

Page 34: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-2 IM 735371-01E

3. Right-click in the program window to show the front panel key menu.

4. On the front panel key menu, click FILE.

5. CheckthatITEMSELECTissettoTRACEonthesoftkeymenu,andclickREAD on the soft key menu.IfITEMSELECTisnotsettoTRACE,clickITEMSELECTtoselectTRACE.

4.1LoadingWaveformDataandDisplayingWaveforms

Page 35: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-3IM 735371-01E

Operations in View

er Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

6. Select the file you want to load and click EXECUTE on the soft key menu.• Thefilesintheuserfolderaredisplayed.Fortheproceduretochangetheuserfolder,

seesection3.3,“SettingtheUserFolder.”• ToloadthefiledirectlyfromtheUSBstoragemedium,clickMEMORYonthesoftkey

menutoselectEXT,andcarryoutthisstep. FortheproceduretochangethedrivetowhichtheUSBstoragemediumisconnected,

seesection3.3,“SettingtheUserFolder.”

DisplayingtheWaveform7. On the soft key menu, click RETURN.

The waveform of the loaded data is displayed as shown below.

4.1LoadingWaveformDataandDisplayingWaveforms

Page 36: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-4 IM 735371-01E

4.2 SavingtheSetupData

You can save the measurement and display conditions you set in Viewer mode by carrying out the procedure below.AnAQ6370Viewerscreenisusedforthisexample.

Procedure1. Right-click in the program window to show the front panel key menu.

2. On the front panel key menu, click FILE.

3. On the soft key menu, click ITEMSELECT.

Page 37: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-5IM 735371-01E

Operations in View

er Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

4. On the soft key menu, click SETTING.

5. On the soft key menu, click WRITE.The file list is displayed.

6. On the soft key menu, click FILENAME.

4.2SavingtheSetupData

Page 38: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-6 IM 735371-01E

7. Type the file name from the keyboard.You can also enter the file name by using the characters and soft keys shown in the characterinputwindow.Fortheinputprocedure,seesection4.3,“EnteringNumericalValuesandStrings”intheOptical Spectrum Analyzer User’s Manual.

8. On the soft key menu, click DONE.The file name is entered.

4.2SavingtheSetupData

Page 39: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-7IM 735371-01E

Operations in View

er Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

9. On the soft key menu, click EXECUTE.The file is saved, and the file name appears in the file list.

4.2SavingtheSetupData

Page 40: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-8 IM 735371-01E

4.3 SoftKeyMenuinViewerMode

Of the soft key menu commands in Viewer mode, those that are not available and those thatareavailablebutcannotbeexecutedaresummarizedinthefollowingtables.Someof the functions may not be listed depending on the model.For details on the soft key menus, see the user’s manual of the relevant optical spectrum analyzer.

UnavailableMenuCommandsFrontPanelKey

Menu SoftKeyMenu Functions

SWEEP AUTOREPEATSINGLESTOPSEGMENTMEASURE

Sweep

DISPLAY DISPLAYOFF DisplayoffMARKER MARKERLISTPRINT PrintoutthemarkervalueANALYSIS RESULTPRINT PrintouttheanalysisresultFILE REMOVEUSBSTORAGE RemovetheUSBstoragemediumPROGRAM PROGRAMEDIT>EDIT>

LISTPRINTPrintouttheprogramlist

OUTPUTWINDOW>PRINTOUTPUTWIN

PrintouttheOUTPUTWINDOW

ADVANCE DATALOGGING>START ExecutesdataloggingSYSTEM(MORE1/4) OPTICALALIGNMENT Executethealignmentadjustmentofthe

monochrome meterWLCALIBRATION Wavelength calibration

SYSTEM(MORE2/4) REMOTEINTERFACE Set the communication interfaceGP-IBSETTING SettheGP-IBinterfaceRS-232SETTING Set the RS-232 interfaceNETWORKSETTING Set the Ethernet interface

SYSTEM(MORE3/4) SETCLOCK Setthedate/timeSYSTEM(MORE4/4) REMOVEUSBSTORAGE RemovetheUSBstoragemedium

VERSION DisplaytheversionandupdatethesoftwareSYSTEMINFORMATION DisplaythesysteminformationRESBWCALIBRATION ExecutermsresolutioncalibrationSHUTDOWN Shutdown the Optical Spectrum Analyzer

systemFEED – Feed the paper

MenuCommandsThatAreAvailableButCannotBeExecutedFrontPanelKey

Menu SoftKeyMenu Functions

PROGRAM PROGRAMEXECUTE>EXECUTE

Executetheprogram(aportionofthecommandsnotexecutable)

Page 41: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

4-9IM 735371-01E

Operations in View

er Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

4.4 CommandsThatDoNotOperateintheProgramFunction

The program function operates as follows in Viewer mode.• PROGRAMEDIT All commands can be entered and edited.• PROGRAMEXECUTE Commandsthatincludehardwareoperationsuchassweepandprinteroperations

cannotbeexecuted.Thetablebelowshowsthecommandsthatcannotbeexecuted.

Command OperationSWEEP AUTO Skip (not processed)

REPEAT Updateonlythemeasurementconditionsand the screenSINGLE

STOPSEGMENTMEASURE Updateonlythemeasurementconditions

and the screenSYSTEM OPTICALALIGNMENT Skip (not processed)

SELFWLCALIBRATIONEXTWLCALIBRATION****.***nmEMISLINEWLCALIBRATION****.***nmEXT-GASWLCALIBRATION****.***nmAUTOOFFSET### ChangeonlytheON/OFFofthesoftkeyREMOVEUSBSTORAGE Skip (not processed)RESBWCALIBRATION

SPECIALCOMMAND

COPYON Skip (not processed)PRINTERFEED**PRINT'------'PRINT@@@@@PRINT@@@@@;PRINTDATAAREAPRINTOUTPUTWINDOWSEND**'-----'SEND**'-----';@SEND**'-----';@;'-----'RESETOPTIONSPOLL**;SSENDRS-232'-----'SENDRS-232'-----';@SENDRS-232'-----';@;'-----'SENDLAN@$,*****'-----'SENDLAN@$,*****'-----';@SENDLAN@$,*****'-----';@;'-----'RECEIVE**;@$SENDRRS-232'-----';@$SENDRLAN@$,*****'-----';@$SETDELIMITER###

Page 42: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

5-1IM 735371-01E

Operations in R

emote C

ontrol Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

5.1 ConnectandDisconnectOperations

You can connect to the Optical Spectrum Analyzer that you wan to remotely control by carrying out the procedure below.AnAQ6370Viewerscreenisusedforthisexample.

ProcedurePreparationsontheOpticalSpectrumAnalyzer

1. ConnecttheOpticalSpectrumAnalyzertoanEthernetnetworkaccordingtotheproceduregiveninsection2.3,“ConnectingandSettingtheEthernetInterfaceoftheOpticalSpectrumAnalyzer.”

Connection2. On the task bar, click the Start button, point to Programs > Yokogawa > AQ6370

Viewer (AQ6360Viewer/AQ6370BViewer/AQ6370CViewer/AQ6370DViewer/AQ6373Viewer/AQ6373BViewer/AQ6374Viewer/AQ6375Viewer) to start the program.

You can also double-click the shortcut icon on the desktop.

3. ClicktheConnect menu.ThefollowingConnectionwindowopens.

Chapter5 OperationsinRemoteControlMode(forthemodel-specificsoftware)

Page 43: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

5-2 IM 735371-01E

4. Type the computername(orIPaddress),portnumber,authenticationusername,and authentication password, and click Connect.• ThecomputernameoftheOpticalSpectrumAnalyzerisasfollows:

AQ6360: “AQ6360@@@@@@@@@” AQ6370: “AQ6370@@@@@@@@@” AQ6370B:“6370B@@@@@@@@@” AQ6370C:“6370C@@@@@@@@@” AQ6370D:“6370D@@@@@@@@@” AQ6373: “6373@@@@@@@@@” AQ6373B:“6373B@@@@@@@@@” AQ6374: “6374@@@@@@@@@” AQ6375: “AQ6375@@@@@@@@@” AQ6375B:“6375B@@@@@@@@@” AQ6376: “6376@@@@@@@@@”

Where@@@@@@@@@istheserialnumber.Theserialnumberisindicatedbynine alphanumeric characters on the rear panel of the Optical Spectrum Analyzer. The computer name cannot be changed.

• FortheportnumberoftheOpticalSpectrumAnalyzer,enterthevalueyouspecifiedwhenyoucarriedouttheproceduregiveninsection2.3,“ConnectingandSettingtheEthernetInterfaceoftheOpticalSpectrumAnalyzer.”Thedefaultvalueis10001.

• Thedefaultauthenticationusernameisanonymous.• Ifaconnectioncannotbeestablished,anerrormessage(seesection7.2,“Messageand

CorrectiveActions”)isdisplayed.• ThesoftwareprogramandtheOpticalSpectrumAnalyzerusetheMD5algorithm(RSA

DataSecurity,Inc.MD5MessageDigestAlgorithm)forthepasswordauthentication.

Disconnection5. ClicktheDisconnect menu.

ThefollowingDisconnectionwindowopens.

6. ClickYES.Viewer mode is activated.

5.1ConnectandDisconnectOperations

Page 44: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

5-3IM 735371-01E

Operations in R

emote C

ontrol Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

5.2 PrecautionstoBeTakenWhenOperatinginRemoteControlMode

FrontPanelKeyMenuOperationinRemoteControlModeIfyouoperatethefrontpanelkeymenuinRemoteControlmode,thefollowingprocessiscarried out.

FrontPanelKeyMenu ProcessCENTER Sends a command that corresponds to the soft key.SPAN Sends a command that corresponds to the soft key.LEVEL Processedbytheprogram(acommandisnotsent).

SWEEP Sends a command that corresponds to the soft key (repeat sweep is a repetition of the single sweep).

ZOOM Processedbytheprogram(acommandisnotsent).SETUP Sends a command that corresponds to the soft key.

TRACE Sends a command that corresponds to the soft key. The function is implemented in the program.

DISPLAY Processedbytheprogram.MARKER Processedbytheprogram(acommandisnotsent).PEAKSEARCH Processedbytheprogram(acommandisnotsent).ANALYSIS Processedbytheprogram(acommandisnotsent).USER Processedbytheprogram.MEMORY Processedbytheprogram.FILE Processedbytheprogram.PROGRAM Processedbytheprogram(acommandisnotsent).ADVANCE Processedbytheprogram(acommandisnotsent).

SYSTEM Sends a command that corresponds to the soft key. The function is implemented in the program.

UNDO/LOCAL Processedbytheprogram(acommandisnotsent).COPY Processedbytheprogram(acommandisnotsent).PRESET Sends a command that corresponds to the soft key. HELP Processedbytheprogram(acommandisnotsent).

AutoOffsetProcessingIfautooffsetisexecutedontheOpticalSpectrumAnalyzerwhilethesoftwareprogramisrunning, the communication sequence may be disturbed, and proper operation may be hindered.Therefore, the program turns the auto offset function OFF when a connection to the OpticalSpectrumAnalyzerisestablishedandinstructstheexecutionoftheautooffsetevery 10 minutes. However, if measurement is in progress at the time the auto offset functionistobeexecuted,theautooffsetisexecutedafterthesweepiscompleted(sameas the operation on the Optical Spectrum Analyzer).

RemoteConnectionandDisconnectionWhen a remote connection is established, the waveform information, measurement conditions, and analysis parameter settings of the Optical Spectrum Analyzer are loaded intothePC.When the remote connection is cut, the measurement conditions and analysis parameter settingsonthePCaretransferredtotheOpticalSpectrumAnalyzer,andthemeasuredwaveform on the Optical Spectrum Analyzer is cleared.

WaveformLoadingDuringtheSweepOperationDuringthesweepoperation,theprogramretrievesthewaveformbeingmeasuredonceasecond from the Optical Spectrum Analyzer and displays the waveform.

AQ6360FrontPanelKeysInRemoteControlmodeofAQ6360Viewer,thecontentsoftheAQ6360mainmenuareshown as panel keys.

Page 45: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

5-4 IM 735371-01E

5.3 SoftKeyMenuinRemoteControlMode

Of the soft key menu commands in remote control mode, those that have the following limitations are summarized in tables. Some of the functions may not be listed depending on the model.For details on the soft key menus, see the user’s manual of the relevant optical spectrum analyzer.• Unavailablemenucommands• Menucommandsthatareavailablebutwouldcausediscrepancieswiththe

waveformsontheopticalspectrumanalyzer.• Menucommandswhoseexecutionprogressisnotdisplayed• Menucommandsthatarenotexecutedontheopticalspectrumanalyzer.

UnavailableMenuCommandsFrontPanelKey

Menu SoftKeyMenu Functions

MARKER MARKERLISTPRINT PrintoutthemarkervalueANALYSIS RESULTPRINT PrintouttheanalysisresultFILE REMOVEUSBSTORAGE RemovetheUSBstoragemediumPROGRAM PROGRAMEXECUTE>

EXECUTEExecutetheprogram

PROGRAMEDIT>EDIT>LISTPRINT

Printouttheprogramlist

OUTPUTWINDOW DisplayouttheOUTPUTWINDOWEXECUTE1toEXECUTE21 Executetheprogramthathasbeen

registered to the soft keyADVANCE DATALOGGING LoggingfunctionSYSTEM(MORE2/4) REMOTEINTERFACE Set the communication interface

GP-IBSETTING SettheGP-IBinterfaceRS-232SETTING Set the RS-232 interfaceNETWORKSETTING Set the Ethernet interface

SYSTEM(MORE3/4) SETCLOCK Setthedate/timeSYSTEM(MORE4/4) REMOVEUSBSTORAGE RemovetheUSBstoragemedium

SHUTDOWN Shutdown the Optical Spectrum Analyzer system

LEVEL Main Scale Initialize Initializetheverticalaxisofthemainscale(AQ6360)

Sub Scale Initialize Initializetheverticalaxisofthesubscale(AQ6360)

FEED – Feed the paper

MenuCommandsThatWouldCauseDiscrepancieswiththeWaveformsontheOpticalSpectrumAnalyzer

FrontPanelKeyMenu SoftKeyMenu Functions

TRACE(MORE1/2) HOLD SettheactivetracetoMAX/MINholdmodeROLLAVG Set the active trace sweep to average mode

DISPLAY NOISEMASK Set the noise mask

Page 46: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

5-5IM 735371-01E

Operations in R

emote C

ontrol Mode (for the m

odel-specific software)

1

2

3

4

5

6

7

8

Index

MenuCommandsWhoseExecutionProgressIsNotDisplayedFrontPanelKey

Menu SoftKeyMenu Functions

SWEEP AUTO Auto sweep (waveform during auto sweep is not displayed)

SYSTEM(MORE1/4) OPTICALALIGNMENT Executethealignmentadjustmentofthemonochrome meter

WLCALIBRATION Wavelength calibrationSYSTEM(MORE4/4) RESBWCALIBRATION Executermsresolutioncalibration

MenuCommandsThatAreNotExecutedontheOpticalSpectrumAnalyzer(ExecutedonlyonthePC)

FrontPanelKeyMenu SoftKeyMenu Functions

ZOOM – Zoom functionMARKER – Marker functionPEAKSEARCH PEAKSEARCH Executethepeaksearch

BOTTOMSEARCH ExecutethebottomsearchSEARCHMODE Set the search modeMULTISRCHSETTING Set the multi search

ANALYSIS – Analysis functionPROGRAM PROGRAMEDIT Edit the programADVANCE TEMPLATE Go/NoGojudgementSYSTEM(MORE1/4) GRIDEDITOR Edit the grid table

USERKEYDEFINE Register the user key

5.3SoftKeyMenuinRemoteControlMode

Page 47: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

6-1IM 735371-01E

File Transfer

1

2

3

4

5

6

7

8

Index

6.1 FileTransferOperation

YoucantransferthefilestoredontheOpticalSpectrumAnalyzertothePCbycarryingout the steps below.AnAQ6370Viewerscreenisusedforthisexample.

ProcedurePreparationsontheOpticalSpectrumAnalyzer

1. ConnecttheOpticalSpectrumAnalyzertoanEthernetnetworkaccordingtotheproceduregiveninsection2.3,“ConnectingandSettingtheEthernetInterfaceoftheOpticalSpectrumAnalyzer.”

Connection2. On the task bar, click the Start button, point to Programs > Yokogawa > AQ6370

Viewer (AQ6360Viewer/AQ6370BViewer/AQ6370CViewer/AQ6370DViewer/AQ6373Viewer/AQ6373BViewer/AQ6374Viewer/AQ6375&76Viewer) to start the program.You can also double-click the shortcut icon on the desktop.

3. ClicktheFileTransfer menu.ThefollowingConnectionwindowopens.IfthisstepiscarriedoutinRemoteControlmode,theConnectionwindowdoesnotopen,and the File Transfer window opens. In this case, proceed to step 5.

4. Type the computername(orIPaddress),portnumber,authenticationusername,and authentication password, and click Connect.• ThecomputernameoftheOpticalSpectrumAnalyzerisasfollows:

AQ6360: “AQ6360@@@@@@@@@” AQ6370: “AQ6370@@@@@@@@@” AQ6370B:“6370B@@@@@@@@@” AQ6370C:“6370C@@@@@@@@@” AQ6370D:“6370D@@@@@@@@@” AQ6373: “6373@@@@@@@@@” AQ6373B:“6373B@@@@@@@@@” AQ6374: “6374@@@@@@@@@” AQ6375: “AQ6375@@@@@@@@@” AQ6375B:“6375B@@@@@@@@@” AQ6376: “6376@@@@@@@@@”

Where @@@@@@@@@istheserialnumber.Theserialnumberisindicated by nine alphanumeric characters on the Optical Spectrum Analyzer rear panel. The computer name cannot be changed.

• FortheportnumberoftheOpticalSpectrumAnalyzer,enterthevalueyouspecifiedwhenyoucarriedouttheproceduregiveninsection2.3,“ConnectingandSettingtheEthernetInterfaceoftheOpticalSpectrumAnalyzer.”Thedefaultvalueis10001.

• The default authentication user name is anonymous.• Ifaconnectioncannotbeestablished,anerrormessage(seesection7.2,“Messageand

CorrectiveActions”)isdisplayed.

Chapter6 FileTransfer

Page 48: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

6-2 IM 735371-01E

• When a connection is established, the File Transfer window opens.

Create a folder (New Folder button)

Optical Spectrum Analyzer file list

PC file list

Finish the file transfer (Exit button)

Status list

Transfer the file from the Optical Spectrum Analyzer to the PC (Download button)

Delete the file or folder (Delete button)

Transfer the file from the PC to the Optical Spectrum Analyzer (Upload button)

Operate the internal memory of the Optical Spectrum Analyzer

Computer name of the Optical Spectrum Analyzer

Operate the USB storage device connected to the Optical Spectrum Analyzer (not selectable when the USB storage device is not inserted)

Download(FileTransferfromtheOpticalSpectrumAnalyzertothePC)5. DisplaythetransferdestinationfolderinthePCfilelist.

6. Select the file you want to transfer in the Optical Spectrum Analyzer file list.

7. ClickDownload. YoucanalsochooseDownloadfromtheFilemenu.

Note• Afilewhosesizeexceeds1MBcannotbetransferredtothePC.• Themaximumnumberoffilesandfoldersthatisshowninthelistis4096.

Upload(FileTransferfromthePCtotheOpticalSpectrumAnalyzer)5. DisplaythetransferdestinationfolderintheOpticalSpectrumAnalyzerfilelist.

6. SelectthefileyouwanttotransferinthePCfilelist.

7. ClickUpload. YoucanalsochooseUploadfromtheFilemenu.

Note• Afilewhosesizeexceeds1MBcannotbetransferredtotheOpticalSpectrumAnalyzer.• Themaximumnumberoffilesandfoldersthatisshowninthelistis4096.

6.1FileTransferOperation

Page 49: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

6-3IM 735371-01E

File Transfer

1

2

3

4

5

6

7

8

Index

DeletingFilesandFolders5. Select the file or folder you want delete in the Optical Spectrum Analyzer file list or

thePCfilelist.

6. ClickDelete. YoucanalsochooseDeletefromtheFilemenu.

NoteFiles and folders that are set to read-only cannot be deleted.

CreatingaFolder5. Select the destination in which the folder is to be created in the Optical Spectrum

AnalyzerfilelistorthePCfilelist.

6. ClickNewFolder. YoucanalsochooseNewFolderfromtheFilemenu.

7. Inthefoldernameinputdialogbox,typethenameofthefolderyouwanttocreate, and click OK.

6.1FileTransferOperation

Page 50: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

7-1IM 735371-01E

Operation of the C

omm

on Software

1

2

3

4

5

6

7

Index

7.1 StarttheCommonSoftware

Start the common software to display the navigation menu.

Procedure1. OntheWindowsstartmenu,clickPrograms>Yokogawa>OSAViewertostart

the software.

You can also start the software by double-clicking its shortcut icon on the desktop.

A navigation menu appears.

Displays the data save destination folder (user folder)

Displays the version and license information of this softwar

Displays the user’ s manual

Starts the Remote Control software

Starts the Viewer software of each model

Starts the File Transfer software

2. Clickthebuttoncorrespondingtothefunctionyouwanttouse. The window for the selected function appears.

ExplanationFunctionsViewer SoftwareYou can select which viewer to start depending on the data you want to view.You can run the viewer simultaneously with the remote control software.Fordetails,seesection7.2,“OperationsontheViewerSoftware(Commonsoftware).

RemoteControlSoftwareYou can remotely control an optical spectrum analyzer connected to the network.You can run the remote control software simultaneously with the viewer software.Fordetails,seesection7.2,“OperationsontheRemoteControlSoftware(Common

software).

FileTransferSoftwareFilessavedinanopticalspectrumanalyzercanbetransferredtothePC.The function is the same as with the model-specific software. For details, see chapter 6, “FileTransferOperation.”

ViewingtheDataSaveDestinationFolderYou can open the user folder set with the model-specific software. You can check the data save destination of the viewer software and the like. For details on setting the user folder,seesection3.3,“SettingtheUserFolder.”

ViewingtheUser’sManualYoucanviewaPDFfileoftheuser’smanual.

ViewingtheVersionandLicenseInformationoftheSoftwareYou can view the version and license information of this software.

Chapter7 OperationoftheCommonSoftware

Page 51: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

7-2 IM 735371-01E

7.2 OperationsontheViewerSoftware(Commonsoftware)

The function is the same as with the model-specific viewer software.Seealsochapter4.

ProcedurePreparingWaveformData

CopyawaveformdatafilethatyouwanttoloadfromaUSBstoragedevicetothefolderspecifiedastheuserfolderaccordingtotheprocedureinsection4.1,“LoadingWaveformDataandDisplayingWaveforms.”

LoadingWaveformData1. On the navigation window, click a Viewer button. The viewer window appears.

Start the appropriate viewer for the data you want to view.

Buttonname SupportedmodelsAQ6360 Series: AQ6360AQ6370 Series: AQ6370D,AQ6370CAQ6373 Series: AQ6373,AQ6373BAQ6374Series: AQ6374AQ6375 Series: AQ6375,AQ6375BAQ6376 Series: AQ6376

2. Loadthewaveformdataaccordingtotheprocedureinsection4.1,“LoadingWaveformDataandDisplayingWaveforms.”

You can also use Open File of the main menu to load the waveform data.

The viewer software operation is the same as the model-specific viewer software. Seechapter4.

MainMenuYou can use the following functions from the main menu.

Load TraceSelect the waveform data to load.

Save ScreenSaves the displayed screen as an image file (BMP, JPEG, or PNG format).

Trace ListLists the optical spectrum analyzer models that measured the waveform data of each trace.See section 3.1, “Main Menu.

Actual Resolution TableLists the actual resolutions (typical values) for the center wavelengths of the AQ6375/AQ6375B/AQ6376/AQ6360 for each resolution setting. See section 3.1, “Main Menu.”

PrintPrints the displayed screen. See section 3.2, “Making a Hard Copy of the Screen.”

Folder SettingSet the folder displayed on the Viewer’ s File menu.

Page 52: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

7-3IM 735371-01E

Operation of the C

omm

on Software

1

2

3

4

5

6

7

Index

Load TraceThe user folder set in section 3.3 opens.Select the waveform data to show in the viewer software, and click Open.

Save ScreenThe user folder set in section 3.3 opens.Set the file name and data format of the image file, and click Save.

PrintA print setup window appears.Setthetargetprinter,numberofcopies,andsoon,andclickPrint.

FolderSettingSet the folder displayed on the Viewer’s File menu.YoucanspecifyaPC’sinternalstorage(INT)andexternalstorageconnectedtothePC(EXT).

TraceList(fortheAQ6360/AQ6374/AQ6375/AQ6375B/AQ6376)Liststheopticalspectrumanalyzermodelsthatmeasuredthewaveformdataofeachtrace.

ActualResolutionTable(fortheAQ6375/AQ6375B/AQ6376)Liststheactualresolutions(typicalvalues)forthecenterwavelengthsoftheopticalspectrum analyzer for each resolution setting.

7.2OperationsontheViewerSoftware(Commonsoftware)

Page 53: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

7-4 IM 735371-01E

7.3 OperationsontheRemoteControlSoftware(Commonsoftware)

The function is the same as with the model-specific remote control software.See also chapter 5.

Procedure1. On the navigation window, click the RemoteControlbutton. A connection setup window appears.

2. Asdescribedinsection5.1,“ConnectandDisconnectOperations,”enterthecomputernameorIPaddress,portnumber,authenticationusername,andpassword. Then click Connect.

ARemoteControlwindowappears.

TheoperationoftheRemoteControlSoftwareisthesameasthemodel-specificRemoteControlSoftware.Seechapter5.

MainMenuYou can use the following functions from the main menu.

Save TraceSaves an image data of the measurement data or window shown on the optical spectrum analyzer to the PC

Load TraceLoads the selected measurement data or setup data into the optical spectrum analyzer

Large、Medium、SmallSets the size of the displayed window

Serial number and IP address of the connected device

Load TraceThe user folder set in section 3.3 opens.Select the data to load into the connected device, and click Open.

Save TraceThe user folder set in section 3.3 opens.Set the file name and the data to save, and click Save.Tosaveimagedata,youcansetthedataformattoBMPorTIFFthroughremotecontrol.YoucanalsosetthecolortoBlack&White,Color,orPresetColor.

Large/Midium/SmallSetthesizeoftheRemoteControlSoftwarewindow.Large:Setsthesizeto150%ofthemediumsettingSmall:Setsthesizeto50%ofthemediumsetting

Page 54: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

7-5IM 735371-01E

Operation of the C

omm

on Software

1

2

3

4

5

6

7

Index

ExplanationThe function is the same as with the model-specific remote control software.You can also display the viewer simultaneously.YoucansavewaveformdatausingRemoteControlandviewitwiththeViewer.

Load TraceYou can load the following types of data.• Trace(*.WXA,*.WX7to*.WX9):Waveformdatameasuredwiththesamemodelas

the connected device• Trace(*.CSV):Measurementdatameasuredwiththeconnecteddevice(CSVformat)• Settingfile(*.STA,*.ST7to*.ST9)Theextensionofthedatathatcanbeloadedvariesdependingontheconnectedmodel.Model WaveformData CSV SetupdataAQ6360 *.WVA *.CSV *.STAAQ6370C/AQ6370D *.WV8 *.CSV *.ST8AQ6373/AQ6373B/AQ6374 *.WV9 *.CSV *.ST9AQ6375/AQ6375B/AQ6376 *.WV7 *.CSV *.ST7

Save TraceYou can save the following types of data.• Trace(*.WXA,*.WX7to*.WX9):Waveformdatameasuredwiththeconnecteddevice• Trace(*.CSV):Measurementdatameasuredwiththeconnecteddevice(CSVformat)• AllTrace(*.CSV):Alltracemeasurementdatameasuredwiththeconnecteddevice

(CSVformat)• Image:Imagedataofthewaveformscreenoftheconnecteddevice(*.BMP,*.TIFF)

7.3OperationsontheRemoteControlSoftware(Commonsoftware)

Page 55: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

8-1IM 735371-01E

Troubleshooting

1

2

3

4

5

6

7

8

Index

8.1 Troubleshooting

If servicing is necessary, or if the program is not operating correctly after performing the corrective actions described below, contact your nearest YOKOGAWA dealer.

Description ProbableCause/CorrectiveAction Reference Section

CannotconnecttotheOpticalSpectrum Analyzer(Errormessage:ConnectionError)

• CheckthatthecomputernameorIPaddressthatyouenteredintheConnectionwindowmatcheswiththatspecifiedontheOpticalSpectrumAnalyzer.

• CheckthattheOpticalSpectrumAnalyzerandthePCareconnectedtothenetworkcorrectlyusingLANcables.

• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheOpticalSpectrum Analyzer(Errormessage:Useraccountdatamismatch.)

• CheckthatthecomputernameorIPaddressthatyouenteredintheConnectionwindowmatcheswiththatspecifiedontheOpticalSpectrumAnalyzer.

2.3

• A connection cannot be established while the Optical Spectrum Analyzer is performing auto offset.If auto offset is in progress, connect after the operation is completed.

5.2

CannotconnecttotheAQ6370(Error message: AQ6370 Remote interface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6370issetto“ETHERNET.”• CheckthattheAQ6370firmwareversionisR02.01orlater.You can

check the version by pressing the SYSTEM key followed by the VERSIONsoftkey.

• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheAQ6370B(Errormessage:AQ6370BRemoteinterface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6370Bissetto“ETHERNET.”• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheAQ6370C(Errormessage:AQ6370CRemoteinterface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6370Cissetto“ETHERNET.”• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheAQ6370D(Errormessage:AQ6370DRemoteinterface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6370Dissetto“ETHERNET.”• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheAQ6373(Error message: AQ6373 Remote interface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6373issetto“ETHERNET.”• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheAQ6373B(Errormessage:AQ6373BRemoteinterface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6373issetto“ETHERNET.”• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

CannotconnecttotheAQ6374,AQ6375,AQ6375B,orAQ6376 (Error message: OSA Remote interface setting or Firmware Version Error.)

• CheckthattheremoteinterfaceoftheAQ6374,AQ6375,AQ6375B,orAQ6376issetto“ETHERNET.”

• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

2.3

The license authentication window appears when starting the program

Executelicenseauthentication.ThelicensecodeneededforthelicenseauthenticationisindicatedontheaccompanyingCDcase.

2.1

The analysis result of the program does not match the analysis result on the Optical Spectrum Analyzer.

• TheversionRxx.xx(wherexxarenumbers)shownwhenyouchoosethe About menu corresponds to the Optical Spectrum Analyzer firmware version. CheckthatthisfirmwareversionandtheOpticalSpectrumAnalyzer firmware version match.

3.1

• ConfirmthatthewaveformanalysiswasconductedontheViewerthat corresponds to the optical spectrum analyzer that measured the waveform data. Otherwise the following analysis results cannot be guaranteed(includingwaveformdatafromtheAQ6317orAQ6319).

Poweranalysis,LEDanalysis,WDManalysis,OSNR(WDM)analysis,EDFA-NFanalysis,dBm/nmmode,anddBm/THzmode

Chapter8 Troubleshooting

Page 56: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

8-2 IM 735371-01E

Description ProbableCause/CorrectiveAction Reference Section

The waveform measured in Remote ControlmodeanddisplayedonthePCdoesnotmatchthewaveformdisplayed on the Optical Spectrum Analyzer.

• Waveforms do not match when the noise mask function is used or when using the following trace settings.

ROLLAVG/MAXHOLD/MINHOLD/CALC• ChangetheOpticalSpectrumAnalyze’sremoteinterfacesettingtoGP-IB,thensetitbackagaintoETHERNET.

LargefilescannotbetransferredinFile Transfer mode.

ThemaximumfilesizeperfilethatcanbetransferredinFileTransfermodeis1MB.

8.1Troubleshooting

Page 57: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

8-3IM 735371-01E

Troubleshooting

1

2

3

4

5

6

7

8

Index

8.2 MessagesandCorrectiveActions

ErrorMessagesThe following error messages may appear while running the software program.

ErrorMessage Description

ConnectionError

CommunicationwiththeOpticalSpectrumAnalyzerfailedduetoany of the following reasons.• An error occurred in the connection to the Optical Spectrum

Analyzer (this error occurs also if the Optical Spectrum Analyzer is already connecting from a different software program).

• An error occurred while sending data to the Optical Spectrum Analyzer.

• A timeout occurred while receiving data from the Optical Spectrum Analyzer.

ConnectionError.AQ6370 Remote interface setting or Firmware Version Error.

• TheremoteinterfaceofthetargetAQ6370isnotsettoETHERNET.

• The firmware version of the target AQ6370 does not support this software program.The AQ6370 firmware version must be R02.01 or later.

ConnectionError.AQ6370BRemoteinterfacesetting or Firmware Version Error.

TheremoteinterfaceofthetargetAQ6370BisnotsettoETHERNET.

ConnectionError.AQ6370CRemoteinterfacesetting or Firmware Version Error.

TheremoteinterfaceofthetargetAQ6370CisnotsettoETHERNET.

ConnectionError.AQ6370DRemoteinterfacesetting or Firmware Version Error.

TheremoteinterfaceofthetargetAQ6370DisnotsettoETHERNET.

ConnectionError.AQ6373 Remote interface setting or Firmware Version Error.

The remote interface of the target AQ6373 is not set to ETHERNET.

ConnectionError.AQ6373BRemoteinterfacesetting or Firmware Version Error.

TheremoteinterfaceofthetargetAQ6373BisnotsettoETHERNET.

ConnectionError.OSA Remote interface setting or Firmware Version Error.

TheremoteinterfaceofthetargetAQ6374/AQ6375/AQ6375B/AQ6376isnotsettoETHERNET.

ConnectionFailed.Useraccountdatamismatch.

• TheaccountinformationusedtoconnecttotheOpticalSpectrum Analyzer does not match with the information set on the Optical Spectrum Analyzer.

• The Optical Spectrum Analyzer could not respond because auto offset was in progress when the software program tried to connect to the Optical Spectrum Analyzer.

WarningMessagesduringRemoteControlBecausethesoftwareprogramretrieveserrorinformationfromtheOpticalSpectrumAnalyzer during remote control, if an error is detected on the Optical Spectrum Analyzer, the warning message for the error is also displayed on the software program. For the cause and corrective action for the warning messages that are displayed while running theprogram,seesection10.10,“WarningDisplayFunction”intheOptical Spectrum Analyzer User’s Manual.

Page 58: er’s Manual AQ6370 Viewer › IM735371-01E.pdfthe Licensed Software is provided to the Licensee on an “as is” basis when delivered, in no event shall Yokogawa warrant that any

Index-1IM 735371-01E

Index

1

2

3

4

5

6

7

8

Index

O Page

operation mode....................................................................... 1-1operation modes, functional differences in ............................. 1-4

P Page

package, contents of ................................................................. ivparameter value...................................................................... 2-3Print .........................................................................3-1, 3-4, 7-3

R Page

READ...................................................................................... 4-2remote control mode............................................................... 1-2remote control mode, front panel key menu operation in ....... 5-3REMOTEPORTNO.,settingof ............................................. 2-8RemotePortNumber.............................................................. 2-7RESCOR ............................................................................... 1-8RPT ........................................................................................ 1-8

S Page

Save Screen ........................................................................... 7-3Save Trace ............................................................................. 7-4screen, hard copy ................................................................... 3-4Setting .................................................................................... 3-2SETTING ................................................................................ 4-5setup data, saving of .............................................................. 4-4SGL ........................................................................................ 1-8SMO OTH ............................................................................... 1-8soft key menu ......................................................................... 4-8soft key menu shapes and functions ...................................... 2-5SPT ......................................................................................... 1-8SRC1-2 .................................................................................. 1-8SRCZOM ............................................................................... 1-8start......................................................................................... 2-1status bar ................................................................................ 1-9sweep operation, waveform loading during ............................ 5-3SWP1-2 ................................................................................. 1-8SWPINT ................................................................................. 1-8system requirements ..................................................................v

T Page

TCP/IP .................................................................................... 2-7TCP/IPsetup .......................................................................... 2-8TLSSYC................................................................................. 1-8TraceList .........................................................................3-3, 7-3

U Page

Update .................................................................................... 1-6Upload .................................................................................... 6-2UserAccount ...................................................................2-7, 2-8UserFolderSetting................................................................. 3-5

V Page

VACWL .................................................................................. 1-8version .............................................................................1-6, 3-3

Wwarning messages.................................................................. 8-3waveform data, loading of ...................................................... 4-1WF SHF .................................................................................. 1-8WRITE .................................................................................... 4-5

Index

A Page

About ...................................................................................... 3-3Actual Resolution Table ...................................................3-3, 7-3AUTANA ................................................................................ 1-8AUTCTR ................................................................................ 1-8AUTOFS ................................................................................ 1-8auto offset processing ............................................................ 5-3AUTREF ................................................................................ 1-8AUTSCL................................................................................. 1-8AUTSRC ................................................................................ 1-8

C Page

commands that do not operate in the program function ......... 4-9computer name........................................................2-8, 5-2, 6-1Connect ...........................................................................3-1, 5-1connection .......................................................................5-1, 6-1CORSIZ ................................................................................. 1-8

D Page

Delete ..................................................................................... 6-3Disconnect .......................................................................3-1, 5-2disconnection...................................................................5-2, 5-3DisplayMenu .......................................................................... 3-3DONE ..................................................................................... 4-6Download................................................................................ 6-2

E Page

error messages....................................................................... 8-3Ethernet connection................................................................ 2-6Ethernet settings..................................................................... 2-6EXECUTE........................................................................4-3, 4-7Exit...................................................................................2-2, 3-1

F Page

File .......................................................................................... 3-1FILE .................................................................................4-2, 4-4FILENAME............................................................................. 4-5FileTransfer .....................................................................3-2, 6-1file transfer mode .................................................................... 1-3folder....................................................................................... 6-3Folder Setting ......................................................................... 7-3front panel key menu .......................................................1-9, 2-3

I Page

installation..................................................................................viITEMSELECT ........................................................................ 4-4

K Page

keyboard ................................................................................. 2-4

L Page

loadable files........................................................................... 1-5LoadTrace.......................................................................7-3, 7-4LVLSHF ................................................................................. 1-8

M Page

mode................................................................................1-1, 4-8

N Page

NewFolder ............................................................................. 6-3NOIMSK ................................................................................ 1-8