6
EQ® Load Centers SELECTION Main Lugs with Copper Bus - - 100,OOOA IR Q ® Features Copper bus load centers are recommended for those applications where the environment may be severe, (i.e. farm and coastal areas) or where a premium panel is desired. Construction offers the same features of the standard EQ 8 III design. EQIII Main Lug Load Center with Trim 2-16 Circuits, 125 Amperes Ampere Rating Branch Circuits Maximum 1-Pole No. of Spaces No. of Circuits QP Max. 2-Poles Indoor Enclosure Type 1 Catalog Number Replace Suffix F (Flush) with S for Surface Mounting List Price S Std. Pkg. Ship. Wt. Lb/St. Pkg. Dimensions linchesl Height Width Depth Outdoor Enclosure Type 3R Catalog Number List Price $ Std. Pkg. Ship. Wt. Lb/Std. Pkg. Dimensions linchesl Height | Width ] Depth 1 Phase, 3 Wire SN 120/240 Volts AC 125 125 125 2 6 8 4 12 16 1 3 4 E0204ML1125FCU® E0612ML1125FCU® E0816ML1125FCU 1 " 74.00 65.00 98.00 1 1 1 8 12 12 17i< 14 s /. 14 3 /. TA m 12% 4'/, M 3% W0204ML1125CU W0612ML1125CU®® W0816ML1125CU®® 120.00 97.00 163.00 1 1 1 9 13 13 17K ' 14 1 /, 14 3 /. 1% 12X 12K 4*A n w Suitable for use as service equipment when not more than six main disconnecting means are provided. Check local codes and restrictions. Ampere Rating Branch Circuits Maximum 1-Pole Number of Spaces Number of Circuits Max. 2-Poles Indoor Enclosure Type 1 Complete Assembly Catalog Number List Price S Ship Wt. Lb/Std. Pkg. of 1 Enclosure Height® (inches) Outdoor Enclosure Type 3R Complete Assembly Catalog Number List Price $ Ship Wt. Lb/Std. Pkg. of 1 Enclosure Height® (inches) 1 Phase, 3 Wire SN® 120/240 Volts AC 125 125 150 150 200 200 200 200 12 16 12 20 12 20 24 30 24 24 24 30 24 40 40 40 6 8 6 10 6 10 12 14 G1224ML1125CU® 0 G1624ML1125CU® G1224ML1150CU®® G2030ML1150CU® G1224ML1200CU®® G2040ML1200CU® G2440ML1200CU® G3040ML1200CU'" 173.00 214.00 212.00 290.00 254.00 354.00 373.00 407.00 23 21 21 24 20 26 29 31 18 21 21 24 24 27 30 33 W1224ML1125CU®® W1624ML1125CU® W1224ML1150CU®® W2030ML1150CU® W1224ML1200CU® 0 W2040ML1200CU® W3040ML1200CU® 234.00 286.00 279.00 367.00 320.00 434.00 480.00 26 31 28 29 28 33 39 19 22 22 25 22 28 34 O r- S 0 3J CO 1 Phase, 3 Wire SN — Full Size Breakers Only® 120/240 Volts AC 125 125 125 200 200 200 225 12 16 20 8 30 40 42 12 16 20 8 30 40 42 6 8 10 4 14 20 20 G1212ML1125CU®® G1616ML1125CU® G2020ML1125CU® GSOSOMLIZOOCU^ 1 G4040ML1200CU® G4242ML1225CU® 137.00 165.00 254.00 375.00 600.00 615.00 22 21 23 31 35 36 18 21 24 33 36 39 W1212ML1125CU® 11 W1616ML1125CU® W2020ML1125CU® W0808ML1200CU® 0 W3030ML1200CU® W4040ML1200CU® W4242ML1225CU® 186.00 228.00 349.00 284.00 444.00 671.00 871.00 25 31 28 23 39 43 44 19 22 25 22 34 37 40 For inches / millimeters conversion, see Application Data section. Hubs — Not furnishedwith outdoor enclosures. See page 194 for data and prices on removable hubs. Wiring Diagramspage 182. Knockout Diagrams Indoor; diagrams, page 195. Outdoor; diagrams, page 197. Circuit Breakers — Not included in above prices. See pages 60 and 63 for data and prices. Accessories page 192. ©Refer to chart on page 213. ^'Suitable for use as service equipment when a main breaker (125A maximum) is back-fed in a branch position, and used with main breaker retainer clip Catalog Number MBR1. ^Indoor enclosures are 14%" wide by 3 16 /s" deep. ©Outdoor enclosures are 14JT wide by 4^" deep. ©UL Listed 5000A IR for 3 phase grounded "B" systems. Use 240V AC circuit breakers only. ©Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance branch circuit panelboard. See article 384-14 and 230-71 of the NEC. ©CSA listed. Discount Schedule B Siemens Electrical Products SPEEDFAX 2000

EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

  • Upload
    others

  • View
    26

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

EQ® Load CentersSELECTION

Main Lugs with Copper Bus - - 100,OOOA IRQ®

FeaturesCopper bus load centers arerecommended for those applicationswhere the environment may be severe,(i.e. farm and coastal areas) or where apremium panel is desired. Constructionoffers the same features of the standardEQ8 III design.

EQIII Main Lug Load Center with Trim

2-16 Circuits, 125 Amperes

AmpereRating

Branch Circuits

Maximum1-Pole

No. ofSpaces

No. ofCircuits

QPMax.

2-Poles

Indoor Enclosure — Type 1

Catalog NumberReplace Suffix F(Flush) with S forSurface Mounting

ListPrice S

Std.

Pkg.

Ship.Wt.Lb/St.Pkg.

Dimensionslinchesl

Height Width Depth

Outdoor Enclosure — Type 3R

CatalogNumber

ListPrice $

Std.

Pkg.

Ship.Wt.

Lb/Std.Pkg.

Dimensionslinchesl

Height | Width ] Depth

1 Phase, 3 Wire SN 120/240 Volts AC125125125

268

41216

134

E0204ML1125FCU®E0612ML1125FCU®E0816ML1125FCU1"

74.0065.0098.00

111

81212

17i<14s/.143/.

TAm12%

4'/,M3%

W0204ML1125CUW0612ML1125CU®®W0816ML1125CU®®

120.0097.00

163.00

111

91313

17K '141/,143/.

1%12X12K

4*Anw

Suitable for use as service equipment when not more than six main disconnecting means are provided. Check local codesand restrictions.

AmpereRating

Branch Circuits

Maximum — 1-Pole

NumberofSpaces

NumberofCircuits

Max.2-Poles

Indoor Enclosure — Type 1

Complete Assembly

CatalogNumber

ListPrice S

Ship Wt.Lb/Std.Pkg. of 1

EnclosureHeight®(inches)

Outdoor Enclosure — Type 3R

Complete Assembly

CatalogNumber

ListPrice $

Ship Wt.Lb/Std.Pkg. of 1

EnclosureHeight®(inches)

1 Phase, 3 Wire SN® 120/240 Volts AC125125

150150

200200200200

1216

1220

12202430

2424

2430

24404040

68

610

6101214

G1224ML1125CU®0

G1624ML1125CU®

G1224ML1150CU®®G2030ML1150CU®

G1224ML1200CU®®G2040ML1200CU®G2440ML1200CU®G3040ML1200CU'"

173.00214.00

212.00290.00

254.00354.00373.00407.00

2321

2124

20262931

1821

2124

24273033

W1224ML1125CU®®W1624ML1125CU®

W1224ML1150CU®®W2030ML1150CU®

W1224ML1200CU®0

W2040ML1200CU®

W3040ML1200CU®

234.00286.00

279.00367.00

320.00434.00

480.00

2631

2829

2833

39

1922

2225

2228

34

O r-

i§S0

3JCO

1 Phase, 3 Wire SN — Full Size Breakers Only® 120/240 Volts AC125125125

200200200

225

121620

83040

42

121620

83040

42

68

10

41420

20

G1212ML1125CU®®G1616ML1125CU®G2020ML1125CU®—GSOSOMLIZOOCU^1

G4040ML1200CU®

G4242ML1225CU®

137.00165.00254.00—375.00600.00

615.00

222123—3135

36

182124—3336

39

W1212ML1125CU®11

W1616ML1125CU®W2020ML1125CU®

W0808ML1200CU®0

W3030ML1200CU®W4040ML1200CU®

W4242ML1225CU®

186.00228.00349.00

284.00444.00671.00

871.00

253128

233943

44

192225

223437

40

For inches / millimeters conversion, see ApplicationData section.

Hubs — Not furnished with outdoor enclosures. See page194 for data and prices on removable hubs.Wiring Diagrams — page 182.Knockout Diagrams — Indoor; diagrams, page 195.Outdoor; diagrams, page 197.Circuit Breakers — Not included in above prices.See pages 60 and 63 for data and prices.Accessories — page 192.

©Refer to chart on page 213.^'Suitable for use as service equipment when a main

breaker (125A maximum) is back-fed in a branchposition, and used with main breaker retainer clipCatalog Number MBR1.

^Indoor enclosures are 14%" wide by 316/s" deep.©Outdoor enclosures are 14JT wide by 4^" deep.©UL Listed 5000A IR for 3 phase grounded "B" systems.

Use 240V AC circuit breakers only.

©Suitable for use as service equipment when not morethan six main disconnecting means are provided andwhen not used as a lighting and appliance branch circuitpanelboard. See article 384-14 and 230-71 of the NEC.

©CSA listed.

Discount Schedule B Siemens Electrical Products SPEEDFAX 2000

Page 2: EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

Molded Case Circuit Breakers

EQ125A FrameQP Plug-in (10,OOOAIR)Non-Interchangeable Trip

SELECTION

ContinuousCurrent Rating@40°C

152025303540455060

70

8090

100

110125

60 Molded Case Switch

1-Pole

120V AC

CatalogNumber

Q1 15®®®Qiao®8®Q1258

Q130®

QUO®

Q150®Q160®

Q170®

ListPrice $

19.3019.3019.3019.30

19.30

19.3019.30

2-Pole

120/240V ACCommon Trip

CatalogNumber

Q215®Q220®Q225®Q230®Q235®Q240®Q245®0250®Q260®

Q270®

Q280Q290®Q2100®

Q2110Q2125

Q260S®

ListPrice S

42.5042.5042.5042.5042.5042.5042.5042.5042.50

88.00

125.00125.00125.00

259.00259.00

28.50

2-Pole®

240V ACCommon Trip

CatalogNumber

Q220R

Q230R

Q240R

Q250RQ260R

Q270R

ListPrice $

125.00

125.00

125.00

125.00125.00

138.00

3-Pole®

240V ACCommon Trip

CatalogNumber

Q315Q320Q325Q330Q3350340Q345Q350Q360

Q370

Q380Q39003100

ListPrice $

150.00150.00150.00150.00150.00150.00150.00150.00150.00

191.00

227.00227.00227.00

QPH Plug-in (22,OOOA IR)152030405060

70

8090

100

110125

Q115H®®Q120H®®Q130H®Q140H®Q150H®

38.5038.5042.50

Q215H®Q220H®Q230H®Q240H®Q250H®Q260H®

Q270H®

Q290H®Q2100H®

Q2110HQ2125H

87.0087.0087.0087.0087.0087.00

138.00

194.00194.00

662.00662.00

Q315HQ320HQ330HQ340HQ350HQ360H

Q370H

Q3100H

232.00232.00232.00232.00232.00

295.00

327.00

HOP Plug-in (65,OOOA IR)152030

405060

70

80100

125

Q115HH®®Q120HH®®Q130HH®8

71.00

Q115HH®Q220HH®Q230HH®

Q260HH®

Q270HH®

Q2100HH®

Q2125HH

180.00

193.00

322.00

397.00

1315.00

Q320HHQ330HH

Q340HHQ350HHQ360HH

Q3100HH

305.00305.00

355.00355.00355.00

426.00

QP/QPH/HOPInternal Accessories (Factory installed only)

Control Voltage

AC

120V

24

Shunt Trip

Add Suffix

...OOS01

...OOS07

List Adder $

117.

117.

Auxiliary Switches

1A and IB

Add Suffix

...A01

...A01

List Adder $

74.

74.

Built to order. Allow 2 weeks for production.

© UL Listed for frequent switching applications (SWD).120V AC Fluorescent Lighting.

3HACR rated.©Non-automatic circuit interrupter.

®For high wattage, tungsten-lamp loads having in-rushcurrents above the instantaneous trip setting of thestandard breaker, add "T" suffix to catalog number.

©UL Listed for use on 3 phase grounded "B" systems —10,000 for this application.

Siemens Electrical Products SPEEDFAX 2000 Discount Schedule A

Page 3: EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

EQ® Load Centers•••••••BBBReference Guide

GENERAL

Description

Convertible Main Panels with Aluminum BusConvertible Main Panels with Copper BusWiring Diagrams, Convertible Main Panel

Main Breaker with Aluminum Bus (22.000A IR)Main Breaker with Copper Bus (22.000A IR)

Main Lugs with Aluminum Bus (100,OOOA IR)Main Lugs with Copper Bus (100.000A IR)Wiring Diagrams, Main Breaker and Main Lugs

3-Phase Main Breaker with Copper Bus CIO.OOOA IR)Main breaker Wiring Diagram3-Phase Main Lugs with Copper Bus (lO.OOOA IR)Main Lug Wiring Diagram

Main Breaker 1 Phase, 3 Phase; 3 Wire, 4 WireMain Lugs 1 Phase, 3 Phase; 3 Wire, 4 WireWiring Diagrams, Main Breaker and Main Lugs

Circuit Breaker Enclosures 1 Phase, 3 Phase; 3 Wire, 4 WireWiring Diagrams, Breaker Enclosure

Riser Panel 1 Phase, 3 Wire (22.000A IR)Riser Panel -Auxiliary Gutter (22.000A IR)Riser Panel Wiring Diagram

Fused/Non-Fused Molded Case Switch Disconnects

Accessories

Replacement Main BreakersLug and Hub DataKnockout Diagrams

Temporary Service 1 Phase, 3 Wire

Pushmatic Circuit Breakers

Indoor

y

yJj

y

y

v

yj

j—y

Outdoor

y

J

y

y

yy

/

y—

AmpereRating

125-225125-225

100-225100-225

60-225125-225

100-225

125-225

300-400400

60-225

125100-225

30-60

100-225

70

15-125

ULListed

»

y</

vy

/•j

y

y

y

yyyy

y/

Suitable foruse asServiceEntranceEquipment

y

jyy

yy

yy

y

y—

——

PageNumberReference

174174175

176177

178179180-182

183183184184

185186187

188188

189189175

190-191

192-193

194194195-197

198

199-200

GeneralProducts Shown In Sections 5 and 6Of This Speedfax Meet Or ExceedThe Following Standards.. UL50 — Electric Cabinets and Boxes

. UL67 — Electric Panelboards

. LJL414 —Meter Sockets

. UL486 — Wire Connectors

. UL489 — Molded-Case Circuit Breakers

. UL869 — Service Equipment

. UL943 — Ground Fault interrupters(Class A — Personnel Protection)

. Federal Specification W-P-115b —Panel Power Distribution

. Federal Specification W-C-375B —Circuit Breakers

. NEC

. NEMA250

Underwriters' Laboratories, Inc.Reference File Numbers:

. EQ Meter Combinations (complying withEUSERC specifications) are listed by ULunder file #E10703

. Uni-Pak (complying with EUSERCspecifications) are listed by UL underfile #E10703

. Underground pull box (complying withEUSERC specifications) are listed by ULunder file #£10703

. Series Connected Circuit BreakerInformation is recognized by UL underfile#E10848(N)

. Pushmatic Circuit Breakers are listed byUL under file #E10848

. EQ Load Centers, Uni-Pak andModular Metering are listed by UL underfile #E10703

EQ Load Centers, Uni-Pak and ModularMetering Accessories are UL recognizedcomponents found under file #E10703,Volume 6 and 7. (Also referenced underthe recognized components directory —section QEUY2)

EQ Circuit Breakers are listed by ULunder file #E82615

Modular metering disconnects are listedby UL under file #£25506

EQ Main Lug Load Centers (wherenoted) and accessories are listed by CSAunder file #LL85900

S5z >S033U>

Siemens Electrical Products SPEEDFAX 2000

Page 4: EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

EQ® Load CentersmmmmmmammmmCatalog Numbering SystemCatalog Numbering System

(Atf

siis

GENERAL

[§]

E = Indoor Type 1 2-1 6 and 30-42 circuits 300-400AmpG = Indoor Type 1 12-42 circuitsW = Outdoor Type 3RT = TrimI = InteriorR = Riser

Maximum number of 1 " breakers (02-42)

Maximum number of circuits

ML = Main LugMB = Main BreakerMC = Convertible

System1 = 1 Phase, 3 Wire3 = 3 Phase, 3 Wire or

3 Phase, 4 Wire

Ex:100 = 100 Amps

Trim / OthersBlank = CombinationS = SurfaceF = FlushT = Feed-Thru LugsB = Bottom feedA = AgriculturalGorGB = Ground Bar Factory Installed

Type of Bus BarBlank = AluminumC or CU = Copper

Blank = 22.000A IR22 = 22.000A IR®42 = 42,000 IR®

12A 1

24t

MB Q]] 100i

LJi

[] CU || 22i i. t i

(T'For 3 phase Load Centers only.

iU| Siemens Electrical Products SPEEDFAX 2000

Page 5: EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

EQ® Load Centers

Main Lugs with Aluminum Bus - - 100,OOOA IRQa-jiT-m,. I Features

EQ® III Load Centers with main lugsfeature a combination trim boxed inone package.

. The trim fits both surface and flushmounting applications saving moneyand space.

. Interiors offer removal in seconds.

. Single phase.

. One piece bus bar construction.Designed for use only with circuitbreakers. UL Listed.

SELECTION

Exclusive split neutral.

Main lugs and neutral on same plane,same drive.

Simple deadfront adjustment after trimis installed.

UL Listed for 60/75°C conductors. Seeequipment markings for applications.

Positive load side circuit breaker hook rails.

EQIII Main Lug Load Center without Trim

2-16 Circuits, 60-125 Amperes

AmpereRating

Branch Circuits

Maximum1-Pole .

No. ofSpaces

No. ofCircuits

QPMax.2-Poles

Indoor Enclosure — Type 1

Catalog Number-Replace Suffix F(Flush) with S forSurface Mounting

ListPrice $

Std.Pkg.

Ship.Wt.

Lb/Std.Pkg.

Dimensions(inches)

Height Width Depth

Outdoor Enclosure — Type 3R

CatalogNumber

ListPrice $

Std.Pkg.

Ship.Wt.

Lb/Std.Pkg.

Dimensions(inches)

Height Width Depth

1 Phase, 3 Wire SN 120/240 Volts AC60

100

125

125125

2

12

4

6

8

4

24

a12

16

1

6

2

34

E0204ML1060F*

E1224ML1100FG '-"

E0408ML1125F" ' "E0612ML1125F®®E0816ML1125F®*

47.00

161.00

50.0057.0090.00

5

1

51

1

16

12

30

1212

m143/,

12%143fuy.

5Ji

raffif

12%12%

2%

mw£13%

W0204ML1060®®

W0408ML1125®®*

87.00

93.00

5—

5

18—

34

8—

ra

5—

6

n—VA

Suitable for use as service equipment when not more than six main disconnecting means are provided. Check local codesand restrictions.

12-42 Circuits, 125-225 Amperes

AmpereRating

Branch Circuits

Maximum — 1-Pole

Number ofSpaces

Number ofCircuits

Maximum2-Poles

Indoor Enclosure — Type 1

Complete Assembly

CatalogNumber®

ListPrice $

Ship Wt.Lb/Std.Pkg. of 1

Enclosure Height®(inches)

1 Phase, 3 Wire SN 120/240 Volts AC125125150

200200200

121620

202430

242430

404040

68

10

101214

G1224ML1125®5

G1624ML1125®

G2030ML1150®

G2040ML1200®G2440ML1200®G3040ML1200"

152.00184.00

262.00

317.00336.00361.00

222023

252830

182124

273033

1 Phase, 3 Wire SN — Full Size Breakers Only 120/240 Volts AC125125125125200200225

12162024304042

12162024304042

68

1012142020

G1212ML1125*®G1616ML1125®G2020ML1125®G2424ML1125

G3030ML1200®G4040ML12001

G4242ML1225®

117.00162.00216.00244.00

326.00540.00

555.00

22202324303435

18212424333639

For inches / millimeters conversion, see ApplicationData section.

Wiring Diagrams —- page 182.Knockout Diagrams — Indoor; diagrams, page 195.Outdoor; diagram Q16, page 197.Additional outdoor diagrams on page 196.Circuit Breakers — Not included in above prices.See pages 60 and 63 for data and prices.Accessories— page 192.3> Refer to chart on page 213.170A maximum breaker.

'^'Suitable for use as service equipment when a mainbreaker OOOA maximum) is back-fed in a branchposition and used with main breaker retainer clipCatalog Number MBR1.

J 100A maximum breaker.^Suitable for use as service entrance equipment when a

main breaker (125A max.) is back-fed in branch positionand used with main breaker retainer clip CatalogNumber MBR1.

A'UL Listed 5,OOOA IR for 3 phase grounded "B" systems.Use 240V AC circuit breakers only.

©Indoor enclosures are 14%" wide by 3%" deep.

^Suitable for use as service equipment when not morethan six main disconnecting means are provided andwhen not used as a lighting and appliance branch circuitpanelboard. See articles 230-71 and 384-14 of the NEC.

®CSA listed.SWill not accommodate 2-pole GFCI or circuit breaker

with shunt trip.'^Available in flush only.

Siemens Electrical Products SPEEDFAX 2000 Discount Schedule B

Page 6: EQ® Load Centers - WESCO...F = Flush T = Feed-Thru Lugs B = Bottom feed A = Agricultural GorGB = Ground Bar Factory Installed Type of Bus Bar Blank = Aluminum C or CU = Copper Blank

EQ Load Centers

Replacement Main Breakers, Lugs, and Hubs100-225 Ampere EQIII Load Centers®Replacement Main Breakers

SELECTION

MainAmpere Rating

10.000A IR

Catalog Number List Price $

22.000A IR

Catalog Number List Price $

42.000A IR

Catalog Number List Price S

65.000A IR

Catalog Number List Price $

1 Phase 120/240V AC

100 Q2100' 134.00 EQ9675R 127.00 Q2100HH 425.00 Q2100HH 425.00

125 O2125 277.00 EQ9677R 264.00 Q2125HH5 1407.00 Q2125HH® 1407.00

150 EQ9683R®® 315.00 EQ9683R = 315.00

200 EQ9685R • 315.00 EQ9685R 315.00

225 EQ9686R2 315.00 EQ9686R®3 315.00

3 Phase 240V AC

100 QJ23B100X 867.00 QJH23B1001 1212.00 QJ23B100H® 1538.00

150 QJ23B150X 867.00 QJH23B150® 1212.00 QJ23B150H 1538.00

200 QJ23B200X 867.00 QJH23B2003 1212.00 QJ23B200H3 1538.00

225 QJ23B225X 867.00 QJH23B2253 1212.00 QJ23B225H0 1538.00

Lug Data Hubs

Load Center Catalog Number

EQ Complete-Enclosed Breaker, Main LugsE0204ML1060 60E0202ML1125 . .' 125W0406ML1225 225E0303ML3100 100E0408ML1125 125E0612ML1125, E0816ML1125 125G1224ML1125 125EB3100 100EB3225 225

EQ Circuit Breaker—Main LugsG1615ML1125, G1624ML1125 125G1224ML1150, G2030ML1150 150G1224ML1200, G2040ML1200, G3030ML1200, G3040ML1200 . 200G2440ML1200, G4040ML1200 200G4242ML1225 225E3030ML1400, E4242ML1400 400E3030ML1600, E4242ML1600 600G1224ML3125 125G1836ML3150, G2442ML3150 150G1224ML3200, G2442ML3200 200G3042ML3200, G4242ML3200 200G4242ML3225 225E3030ML3400, E4242ML3400 400

EQ Circuit Breaker—Single MainG1212MB1100, G1224MB1100, G1616MB1100, G1624MB1100,G2020MB1100 100G1224MC1125, G2024MC1125 125G2424MC1125 125G2430MB1150, G3030MB1150 150G1630MB1150, G2030MB1150 150G2040MB1200, G2430MB1200, G3030MB1200, G3040MB1200,G3040MC1200 200G4040MB1200 200G4242MB1225, G4242MC1225 225E3030MB1400, E4242MB1400 400

E3030MB1600, E4242MB1600 600

G2442MB3150, G3042MB3150 150G3042MB3200, G4242MB3200 200G4242MB3225 225E3030MB3400, E4242MB3400 400

Main Ampere Rating

Copper Aluminum

60125225100125125125100225

125150200200225400600125150200200225400

100125125150150

200200225400

600

150200

400

Wire SizeRange

AWGorkcmil

14-2/04-2/06-2504-2/0

14-2/04-2/04-2/0

14-2/04-300

4-2/01-2501-2501-2504-250

(2)1/0-250(2)2-600

6-3006-3006-3006-3006-300

(2)3/0-250 Cu,(2)4/0-250 Al

4-1/04-1/04-1/01-2501-250

1-2501-2501-250

(2)3/0-250 Cu,(2)4/0-250 Al(2)3/0-500 Cu,(2)4/0-500 Al

4-3004-3004-300

(2)3/0-250 Cu,(2)4/0-250 Al

ConduitSize(inches)

CatalogNumber

HS075HS100HS125HS150HS200HS250

HV200HV250HV300HV350HV400

ListPrice$

25.0025.0025.0025.0044.0071.00

57.0080.00

117.00172.00229.00

Ship.Wt.Lt/Std.

14

Std.

Carton

35

For Use With

r All LoadCentersPlusWB2225,WB3225andW0816ML1200

> FTCU

For inches / millimeters conversion, see ApplicationData section.

®See equipment for exact requirements.©Circuit breaker is four Vpole spaces wide.3)Connector on load end only.©Also includes copper bus and outdoor load centers.SWill not fit load centers with catalog prefix of: EQ, EQC,

FEQ, FEQC, GQ, GQF (Also W versions).

Siemens Electrical Products SPEEDFAX 2000 Discount Schedule B