© 2015 Eastern Technologies, Inc. www.go2eti.com Industry’s most extensive biocide offering - Cooling, Dec. Fountains, Air Washers, Metal Working Fluids, Paper and Food Processing, Potable Water, and O&G field applications Non-oxidizers - Glutaraldehyde 4/15/45% & Glut./Quat 14/42%, DBNPA 5/20% & 40% Tablets, THPS/BD, Isothiazolin, Iso/Bronopol, DGH , Perquat, WSCP 15/30/60%, Bronopol solids - Ask us about our bronopol solid products. Oxidizers - Stabilized Bromine (STABROM 909/PLUS and Maxxis) - DBDMH (XtraBrom 111 & XtraBrom T) - BCDMH, Dichlor, Trichlor, Trichlor/NaBr - NaClO 2 , NaOCl, NaBr We Have What You Need! EPA Registered Biocides These products are proven against biofilm

EPA Registered Biocides

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

•  Industry’s most extensive biocide offering -  Cooling, Dec. Fountains, Air Washers, Metal Working Fluids, Paper and Food

Processing, Potable Water, and O&G field applications

•  Non-oxidizers -  Glutaraldehyde 4/15/45% & Glut./Quat 14/42%, DBNPA 5/20% & 40% Tablets,

THPS/BD, Isothiazolin, Iso/Bronopol, DGH , Perquat, WSCP 15/30/60%, Bronopol solids

-  Ask us about our bronopol solid products.

•  Oxidizers -  Stabilized Bromine (STABROM 909/PLUS and Maxxis) -  DBDMH (XtraBrom 111 & XtraBrom T) -  BCDMH, Dichlor, Trichlor, Trichlor/NaBr -  NaClO2, NaOCl, NaBr

We Have What You Need!

EPA Registered Biocides

 These products are proven against biofilm

Page 2: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

•  THPS/BD – THPS + biodispersant blend -  Especially effective against pseudomonas

•  Iso/Bronopol – isothiazolin/bronopol blend -  Very effective broad-spectrum biocide for open and closed loops

•  DGH - dodecylguanidine hydrochloride -  Very effective broad-spectrum biocide for bacteria, fungi and algae in open loops.

Low actives dose rate.

•  Perquat – catalyzed hydroperoxide -  Quaternary compounds helps peroxygen component penetrate and destroy

biofilm. Excellent for maintenance and remediation.

•  Bronopol – soild products -  Lots of application uses including O&G.

 These products are proven against biofilm

We Have What You Need!

EPA Registered Biocides

Page 3: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Biofilm Life-Cycle

Page 4: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Biofilm Measuring Apparatus

Cost: $999 per Unit

Page 5: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Non-Metallic Coupons

Cost: $60 for 5-Pack or $12 each

Page 6: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Test Solution & Reagents

Cost: ≈$1.80 to $3.50 per Test

Page 7: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

15 Minutes

Peroxide Reacts With Catalase

Page 8: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Result

Correlates with Presence of Biofilm

Page 9: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Weeks BMR 0 0 1 0.49 2 1.33 3 2.78 4 3.42 5 3.9 6 4.3 7 4.63 8 4.95 9 5.15

10 5.3 11 5.41 12 5.5 13 5.58 14 5.66 15 5.63 16 5.6

Optimize Results with Less Risk

Page 10: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

Interpreting Results: <0.27 BMR = no biofilm; no action or possible reduction in biocide feed (especially if feed was turned up in response to a previous high reading).

>0.27 BMR and <2.0 BMR = minor concern; no action or possible slight adjustment to biocide program (depends on exposure time of coupon) and trend of previous results.

>2.0 BMR = biofilm concern; need to adjust biocide program with increase feedrate, frequency or new biocide. Note, if the rubber stopper pops off (prior to reading) the system is likely biofouled.

Interpretation of Result

Because this is a 15 minute test there can be action or conclusion to take no action while on site.

Page 11: EPA Registered Biocides

© 2015 Eastern Technologies, Inc. www.go2eti.com

MB Testing

0 0.25

0.5 0.75

1 1.25

1.5 1.75

2 2.25

2.5 2.75

3 3.25

3.5 3.75

4 4.25

4.5 4.75

5 5.25

5.5 5.75

6 6.25

6.5 6.75

7 7.25

7.5 7.75

8 Dip Slide Coupon HMB

HMB Testing Shows Good Correlation to System