76
Environmental Impact Assessment for TASNEE Petrochemicals Ethylene and Polyethylene Projects ATTACHMENT 6: Noise Sources Applied in the Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated companies and shall be used only for the purpose for which it was supplied. It shall not be copied, reproduced or otherwise used, nor shall such information be furnished in whole or in part to others, except in accordance with the terms of any agreement under which it was supplied or with the prior written consent of Fluor B.V. and shall be returned upon request. Client 1 Jan-08 Annexes updated 0 Dec-05 First issue ®

Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Environmental Impact Assessment for

TASNEE Petrochemicals Ethylene and Polyethylene Projects

ATTACHMENT 6: Noise Sources Applied in the

Calculation Model

This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated companies and shall be used only for the purpose for which it was supplied. It shall not be copied, reproduced or otherwise used, nor shall such information be furnished in whole or in part to others, except in accordance with the terms of any agreement under which it was supplied or with the prior written consent of Fluor B.V. and shall be returned upon request.

Client

1 Jan-08 Annexes updated 0 Dec-05 First issue

®

Page 2: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Environmental Impact Assessment Ethylene Project Attachment 6: Noise sources applied in the calculation model Al-Jubail, Saudi Arabia January 2008

Page 2 of 3 ®

1 INPUT DATA FOR THE NOISE MODEL................................................................ 3

2 ETHYLENE PLANT AND COMMON UTILITIES.................................................... 3

3 HDPE PLANT......................................................................................................... 3

4 LDPE ...................................................................................................................... 3 Annexes to this attachment: Annex 1: Noise Allocation Plan for the Ethylene Plant and the Common Utilities Annex 2: Noise datasheet for the Sea Water Cooling Tower Annex 3: Permit Application for HDPE plant, list of noise sources Annex 4: Electrical load list LDPE plant Annex 5: Input data for the Noise model

Page 3: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Environmental Impact Assessment Ethylene Project Attachment 6: Noise sources applied in the calculation model Al-Jubail, Saudi Arabia January 2008

Page 3 of 3 ®

1 INPUT DATA FOR THE NOISE MODEL

For the EIA Tasnee Ethylene and Polyethylene Projects a noise study has been performed. This Attachment shows the underlying data for the noise study. The total project consists of 3 main parts: Ethylene and common Utilities LDPE HDPE Because the impact on the residential areas has been seen as main objective for the report, only noise sources with approximately the same order of magnitude as the highest 10 noise sources of the Ethylene plant have been modeled as separate noise sources and the other noise sources have been taken together as groups of noise sources. For the whole industrial area, damping for industrial sites according to ISO 9613 has been considered. Apart from the cooling tower, no buildings etc have been considered as this is not permitted by ISO 9613 when damping of industrial sites is considered. The input for the overall noise model can be found in Annex 5 to this attachment.

2 ETHYLENE PLANT AND COMMON UTILITIES

As can be seen in Annex 1, the total sound power level (re. 10 pWatt) of the Ethylene Plant and Common Utilities is approximately 128 dB(A). The largest sound sources for this plant are the Sea Water Cooling Tower, some large Aircooled Heat Exchangers and the main Compressors. These have sound power levels ranging from 126 dB(A) to 115 dB(A).

3 HDPE PLANT

The Permit Application for HDPE plant, list of noise sources contains the sound power levels relevant for the emission to the environment. The total sound Power level of the HDPE plant is 113 dB(A). Taking into account the scale of the noise assessment, the HDPE plant can be modelled as a single item.

4 LDPE

In the LDPE plant the dominant sources are the extruder and the Hyper compressor. Based on the electrical load list and historical data, the sound power levels of the LDPE plant have been estimated.

Page 4: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Ethylene Plant and Common Facilities

TASNEE Petrochemicals Ethylene Project

Al-Jubail, Saudi Arabia

Page: 1 of 29

Intellectual property rights reserved.

EIA TASNEE

ANNEX 1 to Attachment 6

Noise Allocation Report

for

Ethylene Plant and Utilities

Page 5: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 2of 29

Noise Allocation Report

01 12.12.05 Prepared for OWNERS approval R. Huber Biegner Klatt Issue Date Reason for Issue / Remark Prepared Reviewed Approved

Samsung Job No: SC - 2060 Samsung Job Name: Tasnee Ethylene Project

Linde Engineering

Linde Proj. No.: 3110 1199 Linde Proj. Code: Tasnee

Contract/PO No.:

Item No.:

--- Originator's Doc. No.:

Project Doc. No.:

LE-S-RS-1501

Page 6: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 3of 29

Content:

1 PURPOSE.........................................................................................................................4

2 SCOPE..............................................................................................................................4

3 REFERENCES ..................................................................................................................4

4 NOISE LIMITS...................................................................................................................6

4.1 IN-PLANT NOISE LIMITS..................................................................................................6

4.2 ENVIRONMENTAL NOISE LIMIT......................................................................................7

5 EQUIPMENT SOUND POWER LEVELS...........................................................................8

5.1 ETHYLENE UNIT ..............................................................................................................8

5.2 OFF-SITE AND UTILITIES ..............................................................................................14

5.3 TOTAL SOUND POWER LEVEL ....................................................................................20

6 SOUND PROPAGATION CALCULATION.......................................................................21

6.1 GENERAL .......................................................................................................................21

6.2 CONCLUSION.................................................................................................................22 6.2.1 ENVIRONMENTAL NOISE LEVEL..................................................................................22 6.2.2 IN-PLANT NOISE LEVEL ................................................................................................22

7 ATTACHMENTS..............................................................................................................23

7.1 PART A: DOCUMENTATION ..........................................................................................23 7.1.1 NOISE SOURCES...........................................................................................................23 7.1.2 GEOMETRY....................................................................................................................25

7.2 PART B: PLOT PLANS....................................................................................................28 7.2.1 PLOT PLAN FOR PROCESS AREA (Attachment 1) .......................................................28 7.2.2 OVERALL PLOT PLAN (Attachment 2) ..............................Error! Bookmark not defined.

Page 7: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 4of 29

1 PURPOSE

This Noise Allocation Report is to prove that the required sound pressure levels at the Property Fence Line and also the in-plant noise levels will be fulfilled. The expected sound power levels of the equipment and the possible noise reduction measures are calculated in accordance with LINDE's experience. The Plot Plan used for this report is preliminary. Due to changes during engineering phase relocation of equipment and changes is equipment design are likely, but this will influence in general only the in-Plant Noise Contours. The noise at the Property Line will not be affected in relevant scale.

2 SCOPE

This Preliminary Noise Allocation Report documents the relevant noise sources of the TASNEE PETROCHEMICAL ETHYLEN PROJECT (Ethylene, Utilities and off-site facilities) and the results of the Sound Propagation Calculation according to ISO 9613-2 for the noise at the new fence line and also the expected in-plant noise levels. The report shows that the immission sound pressure level caused by the ethylene plant is below the allowable 75 dB(A) at the Property Line.

3 REFERENCES

International Organisation for Standardization (ISO)

ISO 9613-2 Acoustics – Attenuation of sound during propagation outdoors – Part 2: A general method of calculation

ROYAL COMMISSION FOR JUBAIL AND JANBU

Royal Commission Environmental Regulations (Section 7, Issue 2004)

Engineering Equipment and Material Users Association (EEMUA)

EEMUA 140 Noise Procedure Specification

Sound Propagation Calculation

Cadna/A for Windows

Computer program for the calculation and the assessment of outdoor noise immissions according to ISO 9613-2 by Datakustik GmbH / Germany

Plot Plan

Page 8: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 5of 29

Overall Plot Plan SE-L-ZP-0002.001; 25.11.05 by SE

Process Area Plot Plan SE-L-ZP-0003.001; 25.11.05 by SE

Page 9: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 6of 29

4 NOISE LIMITS

The noise limitations are described in Exhibit III Performance Test and Guarantees, Chapter 3.1.5 Noise.

4.1 IN-PLANT NOISE LIMITS

The following limits are valid for the in-plant noise of this Ethylene Unit:

Work Area: 85 dB(A) at 1m distance at any point from any equipment surface accessible for personnel

Restricted Area: 85-115 dB(A) at 1m distance

There are a few areas where the combined sound pressure level inside the plant will higher than 85 dB(A) at 1m distance. These areas are found in the compressor houses and some small areas around the tail gas expander-booster unit and some large pumps and drivers (Wash Water Pump & Steam Turbine, VHP BFW Pump & Steam Turbine, Air Compression Units etc.). These areas will be signposted as “restricted areas”. Noise protection equipment which would be necessary to reduce the noise level of this equipment will hinder access for maintenance of the equipment (e.g. enclosures) and therefore will not be foreseen. Furthermore the daily exposure time of personnel in the restricted areas is normally short. At these areas the use of personnel ear protection is required.

For the following equipment operating during normal plant operation Sound Pressure Levels higher than 85 dB(A) were agreed between OWNER and CONTRACTOR.

Item-No.: Service expected Noise Level in dB(A) at 1m distance

3K-3101 & 3KT-3102 Cracked Gas Comp. & Turbine 98

3K-4401 & 3KT-4402 Ethylene Comp. & Turbine 98

3K-5001 & 3KT-5002

Propylene Comp. & Turbine 98

3P-2871 A/B/S & 3PT-2802

Wash Water Pump & Turbine 93

3P-8371 A/B/S & 3PT-8301

VHP BFW Pump & Turbine 93

Page 10: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 7of 29

3ET-4102 Tail Gas Expander Booster I 93

3ET-4103 Tail Gas Expander Booster II 93

3K-8601 & 3KT-8602 Air Compressor Unit 98

Narrow-Band/ Impulsive Noise:

Any narrow-band or impulsive components shall be reduced sufficiently below the broadband noise from equipment so that it is no longer audible (see Appendix E of EEMUA 140). If this is not possible, the equipment noise limit will be reduced by 5 dB for such equipment.

4.2 ENVIRONMENTAL NOISE LIMIT

The noise radiated from sources in the Ethylene Unit and associated Off-sites and Utilities shall not exceed 75 dB(A) Sound Pressure Level at the Property Fence Line according to the Royal Commission Environmental Requirements.

Page 11: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 8of 29

5 EQUIPMENT SOUND POWER LEVELS

The calculation of Sound Power Levels and Sound Pressure Levels was performed according to LINDES´s experiences with identical or similar equipment. Also manufacturer equipment noise data for standard equipment was considered.

Remarks: -The noise levels for pumps include allowance for piping associated with pumps. -The insulation is in accordance with the insulation shown on the P&ID’s. -The sound power levels include associated gearboxes.

5.1 ETHYLENE UNIT

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Fired Heater 3H-0101 / 0701

Cracking Furnace 1-7

7 85 107 115,5

- S = Burners S = Blowers S = Start-Up LN = E-Motors A/H = Piping A/H = Blower Casing

3PK-8001 A/B

Boiler 2 85 109 112

- S = Burners S = Blowers S = Start-Up LN = E-Motors A/H = Piping A/H = Blower Casing

3PK-3501 Spent Caustic Incinerator

1 85 102 - S = Burners A/H = Piping

3PK-3502 Waste Oil Incinerator

1 85 102 - S = Burners A/H = Piping

Subtotal 117,4

Page 12: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 9of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Let Down Stations PV-1002 Let Down

Station VHP-HP

1 85 108 - A/H = Piping LN = Valves

PV-1008 Let Down Station VHP-HP

1 85 108 - A/H = Piping LN = Valves

PV-1011 Let Down Station HP-MP

1 85 108 - A/H = Piping LN = Valves

PV-1015 Let Down Station MP-LP

1 85 108 - A/H = Piping LN = Valves

Subtotal 114

Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Compressors 3K-3101 Cracked

Gas Compr. 1 - 95 117 A/H = Piping

3K-4401 Ethylene

Compr. 1 - 94 114 A/H = Piping

3K-5001 Propylene

Compr. 1 - 94 114 A/H = Piping

3ET-4102 Tail Gas

Booster I 1 - 93 113 A/H = Piping

3ET-4103 Tail Gas

Booster II 1 - 93 113 A/H = Piping

Subtotal 121,5

Page 13: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 10of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Turbines 3KT-3102 CGC Turb.

1 - 90 110 S = Start-Up

A/H = Piping A/H = Casing

3KT-4402 Ethylene Comp. Turb.

1 - 90 110 S = Start-Up A/H = Piping A/H = Casing

3KT-5002 Propylene Comp. Turb.

1 - 90 110 S = Start-Up A/H = Piping A/H = Casing

3PT-2802 Wash Water Pump Turb.

1 - 92 108 S = Start-Up A/H = Piping A/H = Casing

3PT-8301 A/B

VHP BFW Pump Turb.

2 - 90 105 108

S = Start-Up A/H = Piping A/H = Casing

3PT-3104 Lube Oil Pump Turb. CGC

1 - 85 97 A/H = Piping A/H = Casing

3PT-4404 Lube Oil Pump Turb. Ref. Comp.

1 - 85 97 A/H = Piping A/H = Casing

Subtotal 116,4

Page 14: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 11of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Pumps 3P-8371 A/B/S

VHP BFW Pump

2 1 90 105 108

A/H = Piping

3P-2871 A/B/S

Wash Water Pump

2 1 85 102 105

A/H = Piping

3P-2874 A/S

Cycle Water Pump

1 1 82 95

3P-3971 A/S

Deethanizer Reflux Pump

1 1 82 95

Subtotal 110,0

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: E-Motors for Pumps 3PM-2871 B/S

Wash Water Pump E-Motor

1 1 85 100 LN = E-Motor

3PM-2874 A/S

Cycle Water Pump E-Motor

1 1 82 95 LN = E-Motor

3PM-3971 A/S

Deethanizer Reflux Pump E-Motor

1 1 82 95 LN = E-Motor

3PM-8371 S

VHP BFW Pump E-Motor

- 1 80 (95) LN = E-Motor

Subtotal 102,1

Page 15: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 12of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare

Equipment Type: Air Coolers 3EA-2812 Wash Water

Air Cooler 1 85 116 - A = Piping

3PK-3103 Steam Condension Unit 1

1 85 118 - A = Piping

3PK-4403 Steam Condension Unit 2

1 85 118 A = Piping

3PK-5003 Steam Condension Unit 3

1 85 115 A = Piping

Subtotal 123,0

Page 16: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 13of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare

Equipment Type: Other noise sources Intercoolers

CGC 85 107 - - A = Vessels

Intercoolers Ethylene / Propylene Comp.

85 109 - - A = Vessels

Compressor Piping CGC

85 108 - - A = Piping

Compressor Piping Etylene / Propylene

85 105 108

- - A = Piping

Piping and Control Valves

<= 85 116 - - A/H = Piping LN = Valves

3PK-4801 PSA-Unit 1 - 85 110 - A = Piping

Small Pumps ISBL

28 22 < 85 107 - H = Piping

LV E-Motors

28 22 < 85 104 LN = E-Motors

Subtotal 119,2

Page 17: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 14of 29

5.2 OFF-SITE AND UTILITIES

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design

In ope-ration

Spare -single Lw -all operating

Equipment Type: Compressor 3K-7101 A/S

Ethylene Boil-off Gas Comp.

1 1 82 95 A/H = Piping

3K-7301 A/S

Propylene Boil-off Gas Comp.

1 1 82 95 A/H = Piping

3K-1001 Decoking Air Comp.

1 - 82 97 A/H = Piping S = Piping NH = Casing

3K-8601 A/B/S

Air Compressor

2 1 92 107 110

A/H = Piping

Subtotal 110,5

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design

In ope-ration

Spare -single Lw -all operating

Equipment Type: Turbine 3PT-8271 A

Demin Water Transfer Pump Turb.

1 - 82 95 A/H = Piping NH = Casing

3KT-8601 A/B

Air Compressor Turb.

2 - 92 105 108

A/H = Piping A/H = Casing

Subtotal 108,2

Page 18: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 15of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Electrical Motors for Compr. 3KM-7101 A/S

Ethyl. Boil-off Comp. E-Motor

1 1 82 95 LN = E-Motor

3KM-7301 A/S

Propyl. Boil-off Comp. E-Motor

1 1 77 89 LN = E-Motor

3KM-1001 Decoking Air Comp. E-Motor

1 - 82 97 LN = E-Motor NH = Casing

3KM-8601 S

Air Compressor E-Motor

- 1 92 (107) LN = E-Motor

Subtotal 99,5

Page 19: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 16of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

kW

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Pumps 3P-8271 A/S

Demin Water Transfer Pump

1 1 82 95 A/H = Piping

3P-9171 A-I/S

Cooling Water Circ. Pump

9 1 77 92 101,6

A/H = Piping NH = Casing

3P-9172 A/S

Vital Cooling Water Circ. Pump

1 1 82 95 A/H = Piping

3P-9173 A/B/S

Sea Water Make-up Pump

2 1 79 92 95

A/H = Piping

3P-9174 A-I/S

Sea Water Circ. Pump

9 1 77 92 101,6

A/H = Piping NH = Casing

3P-9175 A/S

Vital Sea Water Circ. Pump

1 1 82 95 A/H = Piping

3P-7171 A/B/S

Ethylene Transfer Pump

2 1 79 92 95

A/H = Piping

Subtotal 106,5

Page 20: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 17of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Electrical Motors for Pumps 3PM-8271 S

Demin Water Transfer Pump E-Motor

- 1 82 (95) LN = E-Motor

3PM-9171 A-I/S

Cooling Water Circ. Punp E-Motor

9 1 77 92 101,6

LN = E-Motor NH = Casing

3PM-9172 A/S

Vital Cooling Water Circ. Pump E-Motor

1 1 82 95 LN = E-Motor

3PM-9173 A/B/S

Sea Water Make-up Pump E-Motor

2 1 79 92 95

LN = E-Motor

3PM-9174 A-I/S

Sea Water Circulation Pump E-Motor

9 1 77 92 101,6

LN = E-Motor NH = Casing

3PM-9175 A/S

Vital Sea Water Circ. Pump E-Motor

1 1 82 95 LN = E-Motor

3PM-7171 A/B/S

Ethylene Transfer Pump E-Motor

2 1 79 92 95

LN = E-Motor

Subtotal 106,2

Page 21: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 18of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Cooling Tower 3CT-9101 Cooling

Tower (Air Inlet)

1 (38 cell)

- 85 107 (each side) 110

S = Air Inlet

3CT-9101 Cooling Tower (Air Outlet)

1 (38 cell)

- 85 122 - - LN = E-Motor

Subtotal 122,3

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare -single Lw -all operating

Equipment Type: Air Cooler 3EA-7112 Etylene

Vapour Air Cooler

1 - 85 105 -

Subtotal 105,0

Page 22: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 19of 29

Item Description/Service

Quantity Lp (1m) dB(A) Sound

Pressure Level at

1m distance

Lw dB(A) Sound Power Level

Shaft power/Capacity

RPM Noise Control Measures / Remarks

S = Silencer NH = Noise Hood

A = Sound Insulation H = Heat Insulation

LN = Low Noise Design In

ope-ration

Spare

Equipment Type: Other noise sources Transformer

Substation #1

85** 100 (Sum)

Transformer Substation #6

75** 100 (Sum)

Elevated Flare

1 - - 100 (Sum) (Stand-by only pilot-burners working)

-

Subtotal 104,8 ** at safety distance of 3m

Page 23: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 20of 29

5.3 TOTAL SOUND POWER LEVEL

Lw

dB(A) Sound Power

Level

Remarks

Offsites and Utilities Equipment Subtotal Fire Heaters

117,4

Subtotal Let Down Stations

114,0

Subtotal Compressors

121,5

Subtotal Turbines

116,4

Subtotal Pumps

110,0

Subtotal Electrical Motors for Pumps

102,1

Subtotal Air Coolers

123,0

Subtotal Other Noise Sources

119,2

Subtotal EU 127,5 Subtotal Compressors

110,5

Subtotal Turbines

108,2

Subtotal E-Motors for Compressors

99,5

Subtotal Pumps

106,5

Subtotal Electrical Motors for Pumps

106,2

Subtotal Cooling Tower

122,3

Subtotal Air Cooler

105,0

Subtotal Other Noise Sources

104,8

Subtotal O&U 123,1 Total Sound Power Level 128,9

Page 24: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 21of 29

6 SOUND PROPAGATION CALCULATION

6.1 GENERAL

The main noise sources including the estimated sound power levels calculated by LINDE can be taken from the chapter 5 of this report.

The acoustic plant model and the noise contours are documented in the plot plan added as Attachment 1 and 2.

The sound propagation calculation is executed according to ISO 9613-2 by using the calculation program Cadna/A.

Page 25: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 22of 29

6.2 CONCLUSION

6.2.1 ENVIRONMENTAL NOISE LEVEL

The calculation of the environmental noise level demonstrates that the immision sound pressure level at the OWNERS fence line will be lower than the allowable 75 dB(A) at all locations.

6.2.2 IN-PLANT NOISE LEVEL

The in-plant noise level will be mostly below the limit of 85 dB(A) at 1m from the equipment surface.

There are a few areas where the combined sound pressure level inside the plant will higher than 85 dB(A) at 1m distance. These areas are found in the compressor houses and some small areas around the tail gas expander-booster unit and some large pumps and drivers (Wash Water Pump & Steam Turbine, VHP BFW Pump & Steam Turbine, Air Compression Units etc.). These areas will be signposted as “restricted areas”. Noise protection equipment which would be necessary to reduce the noise level of this equipment will hinder access for maintenance of the equipment (e.g. enclosures) and therefore will not be foreseen. Furthermore the daily exposure time of personnel in the restricted areas is normally short. At these areas the use of personnel ear protection is required.

Page 26: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 23of 29

7 ATTACHMENTS

7.1 PART A: DOCUMENTATION

7.1.1 NOISE SOURCES

7.1.1.1 POINT SOURCES

Name Sound Power Level

Lw Correction Coordinates

Type Value X Y Z dB(A) dB(A) (m) (m) (m)

3H-0701; Cracking Furnace 7 107.0 Lw FH_01 0.4 -46052.95 67583.10 15.00 3PK-8001; Boiler A 109.0 Lw FH_01 2.4 -46067.14 67469.04 10.00 3PK-8001; Boiler B 109.0 Lw FH_01 2.4 -46048.55 67469.04 10.00 3K-5001; Propylene Compr. 114.0 Lw KC_01 -2.3 -45853.89 67561.33 9.00 3K-4401; Ethylene Compr. 114.0 Lw KC_01 -2.3 -45853.96 67574.74 9.00 3ET-4102; Tail Gas Exp./Booster Unit I 113.0 Lw KX_01 12.6 -45797.02 67540.49 2.00 3ET-4103; Tail Gas Exp./Booster Unit II 113.0 Lw KX_01 12.6 -45796.53 67532.28 2.00 3P-2871; Wash Water Pump A 100.0 Lw P_01 19.6 -45984.52 67510.31 3.00 3PT-8301; BFW Pump Turbine A 105.0 Lw DT_01 4.9 -45995.77 67458.85 3.00 3PT-8301; BFW Pump Turbine B 105.0 Lw DT_01 4.9 -45987.64 67458.05 3.00 3P-2874; Cycle Water Pump A 95.0 Lw P_01 14.6 -45986.50 67537.44 2.00 3K-8601; Air Compr. Pack. A 107.0 Lw XK_02 6.2 -45942.53 67461.41 3.00 3K-1001; Decoking Air Compr. Pack incl. E-Motor 100.0 Lw XK_02 -0.8 -45954.09 67464.41 3.00 PV-1002 Let Down Station VHP-HP 108.0 Lw PV_01 -25.7 -45942.39 67532.48 6.00 PV-1008 Let Down Station VHP-HP 108.0 Lw PV_02 -19.2 -45934.68 67532.91 6.00 3PK-8501; Elevated Flare 100.0 Lw FL_01 -48.3 -45728.38 67432.27 155.00 3H-0601; Cracking Furnace 6 107.0 Lw FH_01 0.4 -46052.95 67583.10 15.00 3H-0501; Cracking Furnace 5 107.0 Lw FH_01 0.4 -46052.79 67567.21 15.00 3H-0401; Cracking Furnace 4 107.0 Lw FH_01 0.4 -46052.99 67550.20 15.00 3H-0201; Cracking Furnace 2 107.0 Lw FH_01 0.4 -46052.89 67517.49 15.00 3H-0301; Cracking Furnace 3 107.0 Lw FH_01 0.4 -46053.18 67534.10 15.00 3H-0101; Cracking Furnace 1 107.0 Lw FH_01 0.4 -46053.69 67500.80 15.00 3P-2871; Wash Water Pump B 100.0 Lw P_01 19.6 -45986.03 67519.14 10.00 3K-8601; Air Comp. B 107.0 Lw XK_02 6.2 -45942.04 67466.13 10.00 3KT-3102; Cracked Gas Compressor Turbine 110.0 Lw DT_01 9.9 -45939.20 67539.50 9.00 3PK-3501; Spent Caustic Incinerator 102.0 Lw FH_01 -4.6 -46032.86 67466.35 5.00 3PK-3502; Waste Oil Incinerator 102.0 Lw FH_01 -4.6 -46010.44 67460.07 5.00 3PK-4801; PSA Unit 110.0 Lw RV_01 29.6 -45937.27 67615.97 2.00 3P-9171 A; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -46024.56 67426.07 2.00 3P-9171 B; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -46014.68 67426.08 2.00 3P-9171 C; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -46004.42 67425.81 2.00 3P-9171 D; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45994.63 67425.94 2.00 3P-9171 E; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45984.84 67426.07 2.00 3P-9171 F; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45967.17 67425.93 2.00 3P-9171 G; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45956.92 67425.80 2.00 3P-9171 H; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45947.39 67425.73 2.00 3P-9171 I; C.W. Circulation Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45937.74 67425.94 2.00 3P-9174 A; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -46000.32 67392.80 2.00

3P-9174 B; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45995.82 67392.67 2.00

3P-9174 C; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45991.85 67392.47 2.00

3P-9174 D; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45987.68 67392.40 2.00

3P-9174 E; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45982.78 67392.86 2.00

3P-9174 F; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45978.55 67392.46 2.00

3P-9174 G; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45974.18 67392.73 2.00

3P-9174 H; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45969.62 67392.73 2.00

Page 27: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 24of 29

3P-9174 I; Sea Water Circulation Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45965.32 67393.06 2.00

3P-9173 A; Sea Water Make-Up Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45824.62 67323.57 2.00

3P-9173 B; Sea Water Make-Up Pump incl. E-Motor

95.0 Lw PC_01 3.2 -45828.91 67323.44 2.00

3K-7101 A; Ethylene Boil-off Comp. & E-Motor 98.0 Lw KV_01 17.6 -44167.07 67345.37 2.00 3K-7301 A; Popylene Boil-off Comp. & E-Motor 96.0 Lw KV_01 15.6 -44155.50 67345.37 2.00 3EA-7101; Ethylen Vap. Air Cooler. 105.0 Lw LK_01 24.9 -44165.09 67333.13 5.00 3KT-4402; Ethylene Compressor Steam Turbine 110.0 Lw DT_01 9.9 -45853.86 67581.38 9.00 3KT-5002; Propylene Compressor Steam Turbine 110.0 Lw DT_01 9.9 -45853.74 67554.34 9.00 3PT-2802; Wash Water Pump Turbine 108.0 Lw DT_01 7.9 -45982.20 67512.65 2.00 3PT-3104; Lube Oil System 105.0 Lw DT_01 4.9 -45951.78 67561.81 1.00 3PT-4404; Lube Oil System 105.0 Lw DT_01 4.9 -45865.96 67565.10 1.00 3PT-8201; Demin Water Pump Turbine 95.0 Lw DT_01 -5.1 -45770.98 67590.71 1.00 3KT-8601 A; Air Comp. Turbine 105.0 Lw DT_01 4.9 -45940.00 67461.70 2.00 3KT-8601 B; Air Comp. Turbine 105.0 Lw DT_01 4.9 -45940.32 67466.00 2.00 3P-3971 A; Deethaniser Reflux Pump 95.0 Lw P_01 14.6 -45788.53 67501.68 1.00 3P-8271 A; Demin Water Transfer Pump 95.0 Lw P_01 14.6 -45772.72 67590.89 1.00 3P-8371 A; VHP BFW Pump 105.0 Lw PC_01 13.2 -45993.62 67459.57 3.00 3P-8371 B; VHP BFW Pump 105.0 Lw PC_01 13.2 -45985.56 67459.90 3.00 PV-1011 Let Down Station HP-MP 108.0 Lw PV_02 -19.2 -45855.91 67548.13 6.00 PV-1015 Let Down Station MP-LP 108.0 Lw PV_02 -19.2 -45850.89 67548.13 6.00 3PM-3971 A; Deethaniser Reflux Pump E-Motor 95.0 Lw EM_01 14.5 -45789.50 67501.57 1.00 3PM-32874 A; Cycle Water Pump E-Motor 95.0 Lw EM_01 14.5 -45983.31 67537.28 2.00 3PM-2871 B; Wash Water Pump E-Motor 100.0 Lw EM_01 19.5 -45983.57 67519.29 2.00 3P-9172 A; Vital Cooling Water Circ. Pump incl. E-Motor

98.0 Lw PC_01 6.2 -46040.20 67428.54 1.00

3P-9175 A; Vital Sea Water Circ. Pump incl. E-Motor

98.0 Lw PC_01 6.2 -46005.53 67392.95 1.00

3P-7171 A; Ethylene Transfer Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45660.78 67395.20 1.00 3P-7171 B; Ethylene Transfer Pump incl. E-Motor 95.0 Lw PC_01 3.2 -45649.14 67393.61 1.00

7.1.1.2 LINE SOURCES

Name Sound Power Level

Sound Power Level per m

Lw Correction

Type Value dB(A) dB(A) dB(A)

Cracked Gas Compressor Piping 108.0 88.0 Lw TV_01 28.2 Ethylene Compressor Piping 105.0 85.0 Lw TV_01 25.2 Propylene Compressor Piping 105.0 85.0 Lw TV_01 25.2 Transformers 1 100.0 82.8 Lw EP_01 24.5 Transformers 2 100.0 82.3 Lw EP_01 24.5 3K-3101; Cracked Gas Compressor 117.0 104.7 Lw KC_01 0.7

7.1.1.3 AREA SOURCES (horizontal)

Name Sound Power Level

Sound Power Level per m²

Lw Correction

Type Value dB(A) dB(A) dB(A)

Intercoolers Cracked Gas Compressor 107.0 75.6 Lw ZK_01 27.0 Intercoolers Ethylene / Propylen 109.0 74.4 Lw ZK_01 29.0 Control Valves & Piping EU 116.0 76.6 Lw RV_01 35.6 Small Pumps & LV E-Motors 108.0 63.4 Lw PC_02 22.4 3CT-9101; Sea Water Cooling Tower Outlet 122.0 83.4 Lw CT_01 23.0 3PK-3103; Steam Cond. Unit 1 118.0 84.9 Lw LK_01 37.9 3PK-4403; Steam Cond. Unit 2 118.0 85.0 Lw LK_01 37.9 3PK-5003; Steam Cond. Unit 3 115.0 85.6 Lw LK_01 34.9 3EA-2812; Wash Water Air Cooler 116.0 84.9 Lw LK_01 35.9 3EA-7012; Ethylene Vapour Air Cooler 105.0 89.8 Lw LK_01 24.9

Page 28: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 25of 29

7.1.1.4 AREA SOURCES (vertical)

Name Sound Power Level

Sound Power Level per m²

Lw Correction

Type Value dB(A) dB(A) dB(A)

3CT-9101; Sea Water Cooling Tower Inlet 1 107.0 74.3 Lw" CT_01 -24.7 3CT-9101; Sea Water Cooling Tower Inlet 2 106.9 74.2 Lw" CT_01 -24.8 7.1.2 GEOMETRY

7.1.2.1 GEOMETRY LINE SOURCES

Name Coordinates x y z Ground (m) (m) (m) (m)

Cracked Gas Compressor Piping -45909.11 67518.76 6.00 0.00 -45908.83 67619.55 6.00 0.00 Ethylene Compressor Piping -45828.88 67512.10 6.00 0.00 -45829.20 67614.36 6.00 0.00 Propylene Compressor Piping -45819.19 67512.18 6.00 0.00 -45819.51 67614.26 6.00 0.00 Transformers 1 -46121.00 67444.00 3.00 0.00 -46121.00 67496.00 3.00 0.00 Transformers 2 -45798.45 67381.66 3.00 0.00 -45740.25 67382.19 3.00 0.00 3K-3101; Cracked Gas Compressor -45939.60 67561.01 9.00 0.00 -45939.07 67544.02 9.00 0.00

Page 29: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 26of 29

7.1.2.2 GEOMETRY AREA SOURCES (horizontal)

Name Coordinates x y z Ground (m) (m) (m) (m)

Intercoolers Cracked Gas Compressor -45882.26 67543.06 2.00 0.00 -45899.43 67543.06 2.00 0.00 -45900.42 67620.42 2.00 0.00 -45881.93 67620.42 2.00 0.00 Intercoolers Ethylene / Propylen -45842.51 67505.35 2.00 0.00 -45868.80 67505.49 2.00 0.00 -45867.74 67617.51 2.00 0.00 -45842.90 67618.04 2.00 0.00 Control Valves & Piping EU -46040.19 67484.85 1.00 0.00 -45913.48 67486.04 1.00 0.00 -45913.68 67614.96 1.00 0.00 -45901.63 67615.23 1.00 0.00 -45901.77 67485.01 1.00 0.00 -45836.61 67485.08 1.00 0.00 -45834.82 67614.04 1.00 0.00 -45812.39 67614.63 1.00 0.00 -45812.26 67484.48 1.00 0.00 -45695.97 67485.08 1.00 0.00 -45696.10 67473.29 1.00 0.00 -46040.65 67472.88 1.00 0.00 Small Pumps & LV E-Motors -46015.64 67619.62 1.00 0.00 -45973.55 67619.65 1.00 0.00 -45973.74 67489.27 1.00 0.00 -45961.44 67489.41 1.00 0.00 -45961.16 67529.93 1.00 0.00 -45913.19 67530.33 1.00 0.00 -45913.46 67490.97 1.00 0.00 -45899.88 67491.05 1.00 0.00 -45899.81 67619.64 1.00 0.00 -45880.57 67619.68 1.00 0.00 -45880.58 67490.27 1.00 0.00 -45868.81 67490.28 1.00 0.00 -45868.02 67618.42 1.00 0.00 -45786.67 67618.67 1.00 0.00 -45786.81 67449.94 1.00 0.00 -45868.56 67449.96 1.00 0.00 -45868.56 67476.92 1.00 0.00 -45880.49 67476.46 1.00 0.00 -45880.77 67451.38 1.00 0.00 -46015.82 67451.33 1.00 0.00 3CT-9101; Sea Water Cooling Tower Outlet -46117.16 67375.70 14.50 0.00 -45847.40 67376.16 14.50 0.00 -45847.27 67349.09 14.50 0.00 -46117.16 67349.55 14.50 0.00 3PK-3103; Steam Cond. Unit 1 -45926.59 67619.48 25.00 0.00 -45901.86 67619.55 25.00 0.00 -45901.53 67535.36 25.00 0.00 -45925.72 67535.36 25.00 0.00 3PK-4403; Steam Cond. Unit 2 -45836.07 67614.32 25.00 0.00 -45812.13 67613.66 25.00 0.00 -45812.40 67529.82 25.00 0.00 -45836.33 67529.82 25.00 0.00 3PK-5003; Steam Cond. Unit 3 -45835.87 67525.22 25.00 0.00 -45811.66 67525.09 25.00 0.00 -45812.19 67489.37 25.00 0.00 -45836.20 67488.97 25.00 0.00 -45836.20 67525.42 25.00 0.00 3EA-2812; Wash Water Air Cooler -45974.31 67489.70 12.00 0.00 -45876.41 67489.37 12.00 0.00 -45876.41 67476.60 12.00 0.00 -45974.38 67476.27 12.00 0.00 -45974.51 67489.37 12.00 0.00 3EA-7101; Ethylene Vapour Air Cooler -45818.12 67483.49 5.00 0.00

Page 30: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 27of 29

-45811.69 67482.96 5.00 0.00 -45812.64 67477.29 5.00 0.00 -45817.92 67477.93 5.00 0.00 -45818.12 67483.38 5.00 0.00

7.1.2.3 GEOMETRY AREA SOURCES (vertical)

Name Coordinates x y z Ground (m) (m) (m) (m)

3CT-9101; Sea Water Cooling Tower Inlet 1 -46116.17 67347.82 7.50 0.00 -45847.27 67347.56 7.50 0.00 3CT-9101; Sea Water Cooling Tower Inlet 2 -46116.43 67376.62 7.50 0.00 -45847.20 67376.57 7.50 0.00

7.1.2.4 SPECTRUM OF SOUND POWER LEVELS

Name ID Oktave Spectrum (dB) Data Source Wgt. 31.5 63 125 250 500 1000 2000 4000 8000 A lin

E-Motor EM_01 Li 69.0 70.0 77.0 76.0 76.0 74.0 69.0 67.0 80.5 82.7 MBBM Gasturbine GT_01 Li 113.0 109.0 95.0 91.0 90.0 91.0 93.0 83.0 99.4 114.6 Dampfturbine DT_01 Li 97.2 100.1 97.6 96.2 95.0 91.8 92.0 82.0 100.1 105.0 Kolbenverdichter KV_01 Li 83.0 82.0 81.0 77.0 76.0 71.0 67.0 60.0 80.4 87.7 MBBM Luftkühler LK_01 Li 86.0 85.0 83.0 77.0 73.0 71.0 66.0 60.0 80.1 90.0 Prozeßofen PO_01 Li 104.0 103.0 100.0 98.0 93.0 92.0 88.0 84.0 100.0 108.2 TRAAK Pumpen P_01 Li 69.0 70.0 77.0 76.0 76.0 74.0 69.0 61.0 80.4 82.6 MBBM Regelventile RV_01 Li 44.0 56.0 63.0 69.0 73.0 76.0 74.0 62.0 80.4 79.9 VDI 2713 Turboverdichter TV_01 Li 79.0 68.0 69.0 72.0 74.0 75.0 72.0 60.0 79.8 82.6 Booster B_01 Li 83.0 83.0 82.0 82.0 79.0 77.0 75.0 69.0 84.7 89.5 Atlas Copco Expansionsturbine (Luft) ET_01 Li 86.0 86.0 85.0 85.0 82.0 77.0 78.0 72.0 87.2 92.3 Atlas Copco Luftverdichter (Plant Air) LV_01 Li 86.0 86.0 85.0 88.0 88.0 91.0 90.0 85.0 96.2 96.9 Atlas Copco Zwischenkühler des Turboverd.

ZK_01 Li 52.0 63.0 75.0 75.0 77.0 73.0 64.0 52.0 80.0 81.4

Transformator TR_01 Li 74.0 81.0 92.0 83.0 74.0 73.0 68.0 63.0 56.0 80.4 93.0 MBBM Li 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 7.0 9.5 Cracking Furnace FH_01 Lw 79.0 87.0 93.0 100.0 102.0 99.0 98.0 95.0 86.0 106.6 120.4 MBBM Compressor, Steam Turbine and Cond. Syst.

KC_01 Lw 98.0 103.0 100.0 104.0 108.0 113.0 109.0 104.0 116.3 125.9 MHI 11-KC-301

Pump incl. E-mot. PC_01 Lw 90.7 90.5 89.8 88.7 87.2 84.3 79.2 71.9 91.8 96.9 Ruhrpumpen Pump incl. St.Turb PT_01 Lw 93.3 92.6 91.5 90.5 88.5 89.2 85.3 80.4 94.9 99.3 Ruhrpumpen 53-AE-901 Steam Let Down

PV_01 Lw 75.0 91.0 101.0 108.0 118.0 127.0 131.0 127.0 133.7 133.3 MBBM

53-AE-902 Steam Let Down

PV_02 Lw 62.0 75.0 85.0 94.0 108.0 119.0 125.0 121.0 127.2 126.8 MBBM

Elevated Flares FL_01 Lw (b)

147.9 142.9 135.9 136.9 140.9 143.9 141.9 128.9 148.3 151.5 GBA

Acid Gas Flare FL_02 Lw (b)

115.5 112.5 109.5 102.5 104.5 111.5 115.5 114.5 119.6 121.6 GBA

Pump with Drive PC_02 Lw 74.0 78.0 80.0 79.0 77.0 74.0 72.0 68.0 85.6 101.5 Gabbioneta Air Dryer Pack. XA_01 Lw 98.0 91.0 84.0 77.0 72.0 73.0 88.0 93.0 94.0 100.2 MALONEY IND Ethylene Stor. Boil Off Coll. Pack.

XA_02 Lw 102.0 104.0 100.0 97.0 98.0 95.0 90.0 86.0 102.2 108.3 GEA RAINEY

Transformator EP_01 Lw 39.6 52.9 62.9 69.0 71.8 69.4 60.4 52.4 42.9 75.5 85.3 BRUSH Exp./Booster Unit KX_01 Lw

(b) 49.0 67.0 81.0 89.0 93.0 96.0 94.0 92.0 100.4 100.7 Atlas Copco

Air Compr XK_02 Lw (b)

90.0 90.0 92.0 91.0 93.0 94.0 96.0 90.0 100.8 101.5 INGERSOLL RAND

Cooling Tower CT_01 Li 73.0 80.0 87.0 93.0 95.0 94.0 92.0 90.0 85.0 99.0 100.5

Sound Power Level of plant (totally) PWL = dB(A) ref 10-12 Watt

Page 31: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

TASNEE Petrochemicals Ethylene Project Proj. Doc. No. LE-S-RS-1501 Issue: 01 Page 28of 29

7.2 PART B: PLOT PLANS

7.2.1 PLOT PLAN FOR PROCESS AREA (Attachment 1)

Page 32: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Ethylene Plant and Common Facilities

TASNEE Petrochemicals Ethylene Project

Al-Jubail, Saudi Arabia

Page: 29 of 29

Intellectual property rights reserved.

Page 33: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

EIA TASNEE ANNEX 2 to Attachment 6 Noise datasheet for Sea Water Cooling Tower

Page 34: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

THIS DATA SHEET IS TO BE FILLED IN COMPLETELY BY THE VENDOR !

It is only valid in connection with “General Noise Specification“ LS 910-01 and LE-S-SG-1501 "General Noise Specification for Tasnee Petrochemicals Ethylene

Project – Addendum to LS 910-01".

VNDS LS-910-01 Add. Sheet 26

Sea Water Cooling Tower

3CT-9101

01 27.09.05 Issued for Inquiry R. Huber Biegner Klatt Issue Date Reason for Issue / Remark Prepared Reviewed Approved

Samsung Job No: SC - 2060 Samsung Job Name: Tasnee Ethylene Project

Linde Engineering

Linde Proj. No.: 3110 1199 Linde Proj. Code: Tasnee

Contract/PO No.:

Item No.:

3CT-9101 Originator's Doc. No.:

Project Doc. No.:

LE-S-DE-1511

SOUND SOURCE - APPLICATION

Water flow (m³/h): 123600 Type: Multi-cell (mark applicable) Number of cells: 38 Cross flow Fan Manufacturer: Sirocco Howden Circular Type: ZNF/ENF Counter flow X Fan diameter (m) 26/28 Natural draft Fan speed (rpm) 146.3 Forced draft Drive (kW/rpm) 175/186/1800 Induced draft X Gear type: Right angle shaft

INSTRUCTIONS TO SUPPLIERS

Acoustical definitions, methods, and procedures shall be in accordance with DIN EN ISO 3740, EEMUA 140 and LS 910-01

Page 35: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

All noise levels, Lp or Lw, shall be guaranteed with an upper tolerance of +0 dB; octave band levels are in un-weighted decibels. Lp is Sound Pressure Level in decibels re 20 µPa at 1 meter from the source and Lw is Sound Power Level in decibels re 10E-12 Watts.

The noise guaranteed by the equipment and/or components shall not exceed the more stringent of the noise limits given in the table below, for any of the conditions of operations for which the equipment may normally be expected to be used.

If the equipment generates noise with tonal or impulsive components, the limits shall be taken to be 5 dB more stringent (for the overall, A-wtd level). If the measured Lp levels surrounding the equipment differ by 6 dB or more in any octave band, the Supplier shall complete Sheet 2.

If the equipment noise levels exceed the overall limit(s), OR if the equipment noise levels exceed the octave band limits (in any band) by more than 5 dB, the Supplier shall provide data for acoustically-treated equipment and shall include details and costs of the treatment.

I: Configuration Codes II: Data Source Codes (Completed by Purchaser)

0 Required noise levels in Lp or Lw or both A Noise Test, equipment loaded

(Completed by Supplier) 1 Guaranteed noise levels without acoustical provisions B Noise Test, equipment unloaded (Completed by Supplier) 2 Guaranteed noise levels with acoustical provisions C Noise Test, identical equipment D Noise Test, similar equipment (Completed by Supplier) 3 Estimated noise levels, not necessarily guaranteed E Noise Test, outdoor (free-field) (Completed by Supplier) 4 F Noise Test, other – attach explanation (Completed by Supplier) 5 G Calculation/estimation – attach details,

calculations, and explanations H Other – attach explanation

ACOUSTICAL PERFORMANCE – Standard Design WITH SLANTED SHEETS + NOISE COVER At 29.7 m from the longitudinal side wall of the tower, 1.5 m above ground (west boundary)

Noise measurements and calculations shall be carried out in accordance with DIN EN ISO 3744 or EEMUA 140 To be completed by:

� Purchaser � Seller, if not specified by purchaser � Seller (also indicate, if data is measured or estimated)

OCTAVE BAND CENTER FREQUENCY (HERTZ) OVERALL EQUIPMENT TRAIN AND COMPONENTS

I) Config’n

Code

Level Type 63 125 250 500 1k 2k 4k 8k LIN

. A-

WTD

II) Data

Source

ACOUSTICAL TREAT-

MENT, REMARKS, AND NOTES

Air inlet : Base � 2 Lp* 80.1 77.3 69.7 67.5 65.5 61.7 59.8 58.4 71.2

� 2 Lw 127 124.1 117.6 115.4 112.6 108.9 108 109.3 118.6

� 2 Lp* 83.9 80.6 70.5 64.9 59.5 51.4 46.2 38.9 68.8 Air outlet :Base � 2 Lw 132.9 130.9 126 123.2 120.5 113.7 109.4 105.8 125.4

� 2 Lp* 33.1 29.4 30.7 28.5 18.7 7.4 -1.7 -9.1 27.9 Body : Base � 2 Lw 79.3 75.7 77 75.9 65.2 54.2 45.9 41.4 74.2

� 2 Lp* (64.3) (67.3) (68.2) (69) (66.9) (65.7) (58.2) (48.8) (71.1) E-Motor : Base � 2 Lw (107.8) (111.8) (112.7) (110.7) (109.7) (102.8) (95.8) (85.8) (115.8) � 2 Lp* Gear

� 2 Lw

� 2 Lp* 85.4 82.3 73.1 69.4 66.5 62.1 59.9 58.4 74 "Sum" / Base � 2 Lw 133.9 131.7 126.6 123.8 121.1 114.9 111.7 110.9 126.6

*Measured at 1 meter from any equipment surface or enclosure face (measuring position details are to be included with data submittal). INFORMATION TO BE SUBMITTED WITH THE TENDER – Include all necessary drawings and engineering notes

�� Guaranteed acoustical performance information as indicated above �� Description of measurement details as indicated above (attach additional pages as needed) �� Explanations, details, and/or calculations as prescribed above (attach additional pages, as needed) �� Description of special designs/acoustical treatments used to meet requirements (attach additional pages, as needed) �� Details of added costs for special designs/acoustical treatments (attach additional pages, as needed) �� Completed silencer and/or enclosure data sheet, as applicable �� Other: Gear noise is included in outlet.

All spectra are given only for information, A-weighted values are guaranteed. The motor is positioned on the opposite side from the West Boundary.So the motor noise is negligible at the west boundary.

REMARKS The max. permissible sound power level for the scope of supply is 125 dBA. Plustolerances are not conceded. The max. permissible sound pressure level at 1 m distance from the scope of supply is 85 dBA. Plustolerances are not conceded. We______________ (Company), guarantee to meet the equipment sound level limits as specified above. Signature / Date:

Page 36: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

EIA TASNEE ANNEX 3 to Attachment 6 List of noise sources HDPE plant

Page 37: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

®

Attachment 10

L is t o f no is e s o u rces

P ermit Ap p licatio n fo r H D P E P lant

T AS N E E P etr o chemicals

Al-J u b ail

K ing d o m o f S au d i Arab ia

®

Page 38: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 1 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

G340.0 plant G340 89.5

5A4103 1142 G340.0 BR4201 4NONE Agitator low noise motor, gearbox, low RPM at start 85.0 85.0

5P4103 4042 G340.0 P-4201 37NONE Al-alkyl supply pump low noise motor, gearbox, low RPM at start 84.0 84.0

42 G340.0 V-4202 NONE Air Jet Pump sound insulation 85.0 85.0

G345.0 plant G345 - level 0 #NAME?

5A1102A 1511 G345.0 BR1102A 30NONE Agitator + vessel low noise motor, gearbox, low RPM at start 85.0 85.0

5A1102B 1511 G345.0 BR1102B 30NONE Agitator + vessel low noise motor, gearbox, low RPM at start 85.0 85.0

5A1301 12 G345.2.01 BR1203 110NONE Agitator suspension receiver low noise motor, gearbox, low RPM at start 89.0 89.0

5A1201 35012 G345.2.01 RR1201 250NONE Agitator + R1 low noise motor, gearbox, 750 RPM at start 93.0 93.0

5A1202 35012 G345.2.01 RR1202 250NONE Agitator + R2 low noise motor, gearbox, 750 RPM at start 93.0 93.0

5A1203 350dc G345.2.01 RR1203 250NONE Agitator + R3 low noise motor, gearbox, 750 RPM at start 93.0 93.0

N.A. 12 G345.2.01 RR1204 250NONE Agitator + Post Reactor low noise motor, gearbox, 750 RPM at start 93.0 93.0

5R1201 12 G345.0 R-1201 NONE Reactor R1 polymeric concrete 89.0 89.0

5R1202 12 G345.0 R-1202 NONE Reactor R2 polymeric concrete 89.0 89.0

5R1203 12 G345.0 R-1203 NONE Reactor R3 polymeric concrete 89.0 89.0

N.A. 12 G345.0 R-1204 NONE Post-Reactor NONE 89.0 89.0

5P1104A/B 7011 G345.0.01 P-1104A/B 55NONE hexane feed pump centrifugal low noise motor, 3000 RPM, pump noise hood 85.0 85.0

5P1105 9011 G345.0.01 P-1105 90NONE flushing hexane pump centrifugal low noise motor, 3000 RPM, pump noise hood 85.0 85.0

5P1302A/B 6212 G345.0.01 P-1207A/B 55NONE decanter feed pump centrifugal low noise motor, 1490 RPM, noise hood 83.0 83.0

5P2101A/B 25021 G345.0.01 P-2101A/B 75NONE motherliquor pump centrifugal 1500 RPM, noise hood 82.0 82.0

5P6201A/B 1281 G345.0 P-8101A/B 7.5NONE condensate pump centrifugal 3000 RPM 79.0 79.0

5P6202A/B 1281 G345.0 P-8102A/B 7.5NONE condensate pump piston low noise motor 82.0 82.0

5P3101A/B 2031 G345.0.02 P-3101A/B 15NONE feed pump centrifugal 1500 RPM 82.0 82.0

5P3102A/B 2031 G345.0.02 P-3102/A/B 18.5NONE discharge pump centrifugal 3000 RPM 82.0 82.0

5P3301A/B 332 G345.0 P-3202A/B 7.5NONE wax pump gear low noise motor 82.0 82.0

5P3103A/B 631 G345.0 P-3103A/B 4NONE reflux pump centrifugal 3000 RPM 79.0 79.0

N.A. 33 G345.0 P-3302A/B 15NONE scrubber discharge pump centrifugal low noise motor, 3000 RPM, pump below ground 82.0 82.0

5P3401A/B 834 G345.0 P-3402A/B 7.5NONE discharge pump centrifugal low noise motor, 3000 RPM 77.0 77.0

5P3402A/B 834 G345.0 P-3401A/B 15NONE waste water pump centrifugal 1500 RPM 81.0 81.0

5P1201A 45012 G345.0.11 P-1201A 315NONE outer cooler pump R1 centrifugal low noise motor, 1490 RPM, noise hood 89.0 89.0

5P1201C 5P1201B 45012 G345.0.11 P-1201B 315NONE outer cooler pump R1 centrifugal low noise motor, 1490 RPM, noise hood 89.0 89.0

5P102A 45012 G345.0.11 P-1202A 315NONE outer cooler pump R2 centrifugal low noise motor, 1490 RPM, noise hood 89.0 89.0

5P1202B 45012 G345.0.11 P-1202B 315NONE outer cooler pump R2 centrifugal low noise motor, 1490 RPM, noise hood 89.0 89.0

5P1203A 45012 G345.0.11 P-1203A 315NONE outer cooler pump R3 centrifugal low noise motor, 1490 RPM, noise hood 89.0 89.0

5P1203B 45012 G345.0.11 P-1203B 315NONE outer cooler pump R3 centrifugal low noise motor, 1490 RPM, noise hood 89.0 89.0

G345.0.11 NONE outer cooler

Insulation is difficult because of cooling process

and reasons of maintanance and safety 103.0 104.0

12 G345.0.11 P-1206A 200NONE suspension cooling pump centrifugal low noise motor, 1485 RPM, noise hood 79.0 79.0

12 G345.0.11 P-1206B 200NONE suspension cooling pump centrifugal low noise motor, 1485 RPM, noise hood 79.0 79.0

5P1208A 1512 G345.0.11 P-1208A 15NONE hot water pump centrifugal 1500 RPM 82.0 82.0

5P1209 1512 G345.0.11 P-1208B 15NONE hot water pump centrifugal 1500 RPM 82.0 82.0

5P1210 1512 G345.0.11 P-1208C 15NONE hot water pump centrifugal 1500 RPM 82.0 82.0

N.A. 12 G345.0 P-1281 5.5NONE B-1205 discharge pump centrifugal 77.5 77.5

N.A. 83 G345.0 P-8301A/B 330NONE secundary cooling water low noise motor, 1000 RPM, insulation 90.0 90.0

5C6101 250082 G345.0.01 V-8201 1500YES refrigeration compressor standard soundproofing, room enclosure 123.0 90.0

Basell Prelimary Information - For Information Only!

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 39: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 2 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

Basell Prelimary Information - For Information Only!

5C2203A/B 200 24 G345.0.03 V-2401 200 YES transport nitrogen compressor Roots

soundproofing, silencers, piping insulation, room

enclosure 102.0 86.0

5F2402 24 G345.3.01 F-2401 NONE Filter 82.0 82.0

5C2402A/B 400 25 G345.0.03 V-2501A/B 400 YES transport nitrogen compressor screw

soundproofing, silencers, piping insulation, room

enclosure 104.0 88.0

5C2204 21 G345.3.01 V-2101 7.5 NONE nitrogen recycling blower silencers on pressure & suction 83.0 83.0

5F2201 21 G345.3.01 F-2101 NONE Leak Gas Filter 82.0 82.0

/ G345.0 NONE valves silenced valves, piping insulation 88.0 88.0

/ G345.0 NONE other sources 92.0 92.0

G345.1 plant G345 - level +9 #NAME?

5P1204 40 12 G345.2.01 P-1204A/B 37 NONE flash vessel pump 1 centrifugal low noise motor, 2955 RPM, noise hood 82.0 82.0

5P1205 80 12 G345.2.01 P-1205A/B 37 NONE flash vessel pump 2 centrifugal low noise motor, 2955 RPM, noise hood 82.0 82.0

5S2203 5 21 G345.1 F-2104 NONE vibrating screen space around equipment for further noise hooding 88.0 88.0

N.A. 21 G345.1 P-2103A/B 18.5 NONE motherliquor pump centrifugal low noise motor, 3000 RPM 82.0 82.0

5P6101 140 82 G345.1.01 P-8201A/B 90 NONE cold hexane pump centrifugal 1500 RPM, noise hood 82.0 82.0

5A3402 34 G345.1.02 BR-3402 45 NONE agitator distillation vessel I 87.0 87.0

/ 34 G345.1.02 BR-3404 45 NONE agitator distillation vessel II 87.0 87.0

N.A. G345.1 NONE small pumps 88.0 88.0

/ G345.1 NONE valves silenced valves, piping insulation 88.0 88.0

/ G345.1 NONE other sources 88.0 88.0

5P6102 140 temperate Hexane pump

G345.2 plant G345 - level +17 #NAME?

5P2201A/B 21 G345.2 P-2102A/B 7.5 NONE scrubber circulation pump centrifugal low noise motor 85.0 85.0

5C2202 21 G345.2.01 V-2103 132 NONE fan drying nitrogen

noise hood or room enclosure, silencers,

insulation 85.0 85.0

N.A. 83 G345.2.01 P-8302 20 NONE cooling water booster pump centrifugal low noise motor 82.0 82.0

N.A. 12 G345.2 BR1201 11 NONE Agitator flash vessel 1 low noise motor, gearbox, low RPM at start

N.A. 12 G345.2 BR1202 11 NONE Agitator flash vessel 2 low noise motor, gearbox, low RPM at start

N.A. 12 G345.2 F-1201A/B NONE Filters for lumps 85.0 85.0

from PDP N.A. G345.2 NONE air for V-8201 room 85.0 85.0

/ G345.2 NONE small pumps 85.0 85.0

/ G345.2 NONE valves silenced valves, piping insulation 88.0 88.0

/ G345.2 NONE other sources 86.0 86.0

G345.3 plant G345 - level +25.5 #NAME?

5C3501 12 G345.3.01 V-1201A/B 75 YES off gas compressor liquid ring room enclosure 80.0

5C3502 12 G345.3.01 V-1202A/B 200 YES off gas compressor liquid ring room enclosure 80.0

5S2101A 450 21 G345.3.01 S-2101A 355 YES decanter centrifuge insulation, room enclosure 101.0 80.0

5S2101B 450 21 G345.3.01 S-2101B 355 YES decanter centrifuge insulation, room enclosure 101.0 80.0

5S2101C 450 21 G345.3.01 S-2101C 355 YES decanter centrifuge insulation, room enclosure 101.0 80.0

/ G345.3 NONE valves silenced valves, piping insulation 88.0 88.0

/ G345.3 NONE other sources 84.0 84.0

/

G345.4 plant G345 - level +33 #NAME?

5S2201 21 G345.4 F-2103A NONE cyclone separator sound insulation SI60 82.0 82.0

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 40: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 3 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

Basell Prelimary Information - For Information Only!

5S2202 21 G345.4 F-2103B NONE cyclone separator sound insulation SI60 82.0 82.0

5C2201 21 G345.3.01 V-2104 132 NONE fan drying nitrogen room enclosure 83.0 83.0

22 G345.4.01 P-2201 0.55 NONE metering pump 75.0

5PK2301 22 G345.4 V-2202A/B 132 NONE hydraulic circuit compressor noise hood, piping insulation 90.0 90.0

5F2302 22 G345.4 F-2202 NONE Filter 84.0 84.0

5PK2301 22 G345.4.01 V-2203A/B 37 NONE vacuum unit compressor noise hood, piping insulation 87.0 87.0

5F2303 22 G345.3.01 F-2203 NONE Leak Gas Filter 82.0 82.0

N.A. 22 G345.4.01 P-2203A/B 0.75 NONE membrane separator 75.0 75.0

/ G345.4 NONE valves silenced valves, piping insulation 88.0 88.0

/ G345.4 NONE other sources 86.0 86.0

G350.0 plant G350 - level 0 #NAME?

5D5303/5A5301 51 G350.0.01 BR5102 1 YES Agitator + vessel room enclosure 95.0 75.0

5P5301 100 51 G350.0.01 P-5101A/B 110 YES transport water pump centrifugal 3000 RPM, room enclosure 93.0 73.0

5PK5302 1800 51 G350.0.01 P-5103 1200 YES gear pump + pelletizer gear room enclosure, low noise motor and gearbox 96.0 76.0

5PK5302 14500 51 G350.0.02 R-5101 10500 YES extruder room enclosure 110.0 90.0

100 61 G350.0.03 P-6101A/B 37 YES transport water pump centrifugal 3000 RPM, room enclosure 84.0 64.0

37 YES transport water pump centrifugal 3000 RPM, room enclosure 84.0 64.0

5PK5102 14500 61 G350.0.04 R-6101 3800 YES extruder room enclosure 113.0 93.0

5PK5102 1800 G350.0 15 YES gear pump + pelletizer room enclosure 75.0 75.0

5C5401A 400 74 G350.0.07 V-7401A 355 YES conveying air compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 103.0 86.0

5C5401B 400 74 G350.0.07 V-7401B 355 YES conveying air compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 103.0 86.0

5C5401C 400 74 G350.0.07 V-7401C 355 YES conveying air compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 103.0 86.0

5C5401D 400 74 G350.0.07 V-7401D 355 YES conveying air compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 103.0 86.0

5C5401E 400 74 G350.0.07 V-7401E/F 355 YES conveying air compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 103.0 86.0

/ 74 G350.0.07 V-7402A/B 240 YES conveying air compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 98.0 81.0

/ 25 G350.0.07 V-2502A/B 250 YES transport nitrogen compressor screw

low noise motor, 1500 RPM, silencers, room

enclosure 102.0 85.0

/ 25 G350.0.07 V-2503A/B 90 YES transport nitrogen compressor Roots

low noise motor, 1500 RPM, silencers, room

enclosure 101.0 84.0

/ 25 G350.0.08 V-2504 75 YES fluidization blower screw room enclosure 94.0 77.0

N.A. from PDP 53 G350.0 V-5303 0.55 YES fan for carbon black bunker ventilation centrifugal inside unloading pit (use only daytime) 92.0 75.0

5D5105A-D 23 G350.0 B-2301A-E NONE silos only 1 silo operating 90.0 90.0

5D5305A-B 23 G350.0 B-2301F-L NONE silos only 1 silo operating 90.0 90.0

/ 23 G350.0 F-2301A-E NONE dust filter sound insulation 82.0 82.0

/ 23 G350.0 F-2301F-L NONE dust filter sound insulation 82.0 82.0

G350.0 NONE bucket wheels insulation for leak gas piping 93.0

G350.0 NONE other sources 89.0 89.0

G350.1 plant G350 - level +9 #NAME?

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 41: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 4 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

Basell Prelimary Information - For Information Only!

51 G350.1 R-5101 YES extruder upperfloor components room enclosure, Lp inside<85dB(A) 80.0

61 G350.1 R-6101 YES extruder upperfloor components room enclosure, Lp inside<85dB(A) 80.0

/ 25 G350.1 V-2505A 55 NONE transport nitrogen fan centrifugal low noise motor, 1500 RPM, soundproofed case 82.0 82.0

/ 25 G350.1 V-2505B 55 NONE transport nitrogen fan centrifugal low noise motor, 1500 RPM, soundproofed case 82.0 82.0

25 G350.1 F-2501 NONE Filter 90.0 90.0

/ G350.1 NONE ventilation system compressor room soundproofing, sound insulation 92.0 92.0

/ G350.1 NONE ventilation system extruder room soundproofing, sound insulation 95.0 95.0

G350.1 NONE other sources 93.0 93.0

G350.2 plant G350 - level +15.5 #NAME?

5S5103 28 61 G350.2 T-6101A/B 18.5 YES dryer with vibrating screen

room enclosure, Lp inside<90dB(A), full

soundproofing for dryer unit 104.0 84.0

5S5303 28 51 G350.3 T-5101 25 YES dryer with vibrating screen

room enclosure, Lp inside<90dB(A), full

soundproofing for dryer unit 104.0 84.0

N.A. from PDP 51 G350.3 V-5101 0.4 YES waste air suction fan room enclosure, Lp inside<90dB(A) 85.0 65.0

5C5301 10 51 G350.3.02 V-5102 7.5 YES dryer fan room enclosure, Lp inside<90dB(A) 90.0 70.0

/ 52 G350.3.02 V-5201 37 YES waste air blower 1500 RPM, silencers 90.0 70.0

/ 53 G350.3.02 V-5301 18.5 YES waste air blower 1500 RPM, silencers 92.0 72.0

/ 61 G350.3.02 V-6102A/B 3 YES waste air suction fan room enclosure, Lp inside<90dB(A) 90.0 70.0

/ G350.2 YES all equipment at level +15.5 room enclosure, Lp inside<85dB(A) 95.0 75.0

/ G350.2 NONE other sources 99.0 79.0

G350.3 plant G350 - level +23/+31 #NAME?

5F5102 51 G350.3.01 F-5103 NONE dust filter 80.0 80.0

5F5302 61 G350.3.01 F-6103 NONE dust filter 80.0 80.0

51 G350.3 O-51 NONE all other equipment at level +23 sound insulation 80.0 80.0

5F5101 51 G350.4 F-5101 NONE silo vent filter 82.0 82.0

52 G350.4 F-5201A-C NONE silo vent filter 82.0 82.0

53 G350.4 F-5301A/B NONE silo vent filter 82.0 82.0

5F5301 61 G350.4 F-6101 NONE silo vent filter 82.0 82.0

G350.3 NONE other sources 85.0 85.0

G355.0 plant G355 - level 0 #NAME?

G355.0 NONE bucket wheels outlet with silencer, insulated filters 85.0 85.0

G355.0 NONE silos piping separation from silo, muffs, 1 m connection 101.0 101.0

G355.0 NONE analysis silos piping separation from silo, muffs, 1 m connection 98.0 98.0

G355.0 NONE silos NT piping separation from silo, muffs, 1 m connection 95.0 95.0

G355.0 NONE other sources 92.0 92.0

G360.0 plant G360 - level 0 #NAME?

5P4101A/B 50 41 G360.0.02 P-4101A/B 30 NONE feed pump centrifugal 3000 RPM 82.0 82.0

5P4102A/B 50 41 G360.0.02 P-4102/A/B 37 NONE motherliquor pump centrifugal 3000 RPM 85.0 85.0

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 42: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 5 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

Basell Prelimary Information - For Information Only!

5P4104 3 41 G360.0 P-4103 3 NONE hexane unloading pump centrifugal 1500 RPM 78.0 78.0

/ 41 G360.0 P-4104 4 NONE transportable suction pump centrifugal flexible piping connected 76.0 76.0

/ 41 G360.0 P-4105 11 NONE suction pump centrifugal working on daytime

G360.0 NONE other sources 84.0 84.0

G365.0 plant G365 - level 0 #NAME?

G365.0 YES pellet cooling blower W alls/roof root

noise hood, room enclosure, Lp inside <105dB(A)

R'w=45 (l17;b11;h10) 84.7

G365.0 YES pellet cooling blower Gates root

noise hood, room enclosure, Lp inside <105dB(A)

R'w=37 (l17;b11;h10) 75.0

G365.0 YES ventilation openings opening silencers 83.0 83.0

G365.0 noise hood openings pressure side opening silencers 83.0 89.0

G365.0 noise hood openings suction side opening silencers 83.0 89.0

G365.0 blower suction openings opening silencers 89.0

G365.1 plant G365 - level 1 #NAME?

71 G365.1 F-7101A-C NONE blower discharge filters (each 78 dB(A)) 83.0 84.0

G365.1 NONE DN1000 discharge piping NONE 89.0 89.0

G370.0 plant G370 - level 0 #NAME?

r G370.0 air feeding 7.5 NONE 2 fans 12700 m3/h each AU 85.0

r G370.0 air feeding 5 NONE 2 fans 7000 m3/h each FO

r G370.0 air circulation 7.5 NONE 2 fans 11700 m3/h each circulation

of G370.0 roof fan 1.5 NONE 1 fan 3000 m3/h discharge

of G370.0 roof fan 0.75 NONE 1 fan 700 m3/h discharge

of G370.0 roof fan NONE 1 fan 3800 m3/h discharge

of G370.0 roof fan 0.05 NONE 1 fan 500 m3/h discharge

mo G370.0 remove smoke 4 NONE 4 fans 5000 m3/h each discharge

G370.0 NONE other sources 81.0 81.0

G375.0 plant G375 - level 0 #NAME?

r G375.0 air for LV room 15 NONE 2 fans 23500 m3/h each suction 85.0

r G375.0 air for LV room 7.5 NONE 2 fans 23500 m3/h each discharge

mo G375.0 remove smoke 4 NONE 4 fans 5700 m3/h each discharge

an G375.0 transformers NONE 85.0 85.0

G375.0 NONE other sources 83.0 83.0

G379.0 plant G379 - level 0 #NAME?

G379.0 V-7101 A-C YES

r G379.0 air for HV room 15 YES 2 fans 23500 m3/h each suction 85.0

r G379.0 air for HV room 7.5 NONE 2 fans 23500 m3/h each discharge

mo G379.0 remove smoke 4 NONE 4 fans 5500 m3/h each discharge

an G379.0 transformers NONE 85.0 85.0

G379.0 NONE other sources 83.0 83.0

Ventilation system plant various - level 0 #NAME?

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 43: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 6 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

Basell Prelimary Information - For Information Only!

r G354 air for HV room 29 NONE 9 systems 77100 m3/h total suct+disch 88.0

r G350 air for HV room 204.5 NONE 19 systems 1057480 m3/h total suct+disch 95.0

mo Others remove smoke NONE suct+disch 85.0

Pneumatic haulage system plant pneumatic haulage - level 0 #REF!

Nr Product from to Flow type Lw(A) without Soundproofing

Noise

reduction Sound Proofing System Lw(A)

1.1 Powder H-2103 B-2201 Fluid 100 -5 A 95.0

1.2 Powder H-2103 B-5101 Fluid 103 -5 A 98.0

1.3 Powder H-2103 B-6101 Fluid 102 -5 A 97.0

1.4 Powder H-2103 B-2301 Fluid 103 -5 A 98.0

2.1 Powder H-2204 B-5101 Fluid 102 -5 A 97.0

2.2 Powder H-2204 B-6101 Fluid 102 -5 A 97.0

2.3 Powder H-2204 B-2301 Fluid 103 -5 A 98.0

3.1 Powder H-2301 B-5101 Fluid 100 -5 A 95.0

3.2 Powder H-2301 B-6101 Fluid 100 -5 A 95.0

4.1 Powder H-2302 B-2302 Fluid 98 -5 A 93.0

4.2 Powder H-2302 B-5101 Fluid 100 -5 A 95.0

4.3 Powder H-2302 B-6101 Fluid 99 -5 A 94.0

5.1 Pellet H-5105 B-7101 Dense 106 -15 B 91.0

5.2 Pellet H-5105 B-5401 Dense 104 -15 B 89.0

6.1 Pellet H-6105 B-7301 Dense 104 -15 B 89.0

6.2 Pellet H-6105 B-7301 Dense 103 -15 B 88.0

6.3 Pellet H-6105 B-7201 Dense 104 -15 B 89.0

7.1 Pellet H-6105 B-7301 Dense 103 -15 B 88.0

7.2 Pellet H-6105 B-6401 Dense 101 -15 B 86.0

7.3 Pellet H-6105 B-7202 Dense 104 -15 B 89.0

8.1 Pellet H-7108 B-7101 Dense 104 -15 B 89.0

8.2 Pellet H-7108 B-5401 Dense 107 -15 B 92.0

8.3 Pellet H-7101 B-7101 Dense 106 -15 B 91.0

8.4 Pellet H-7108 Log.black Dense 109 -15 B 94.0

9.1 Pellet H-7207 B-7301 Dense 102 -15 B 87.0

9.2 Pellet H-7207 B-5401 Dense 102 -15 B 87.0

10.1 Pellet H-7207 B-7301 Dense 102 -15 B 87.0

10.2 Pellet H-7207 B-5401 Dense 102 -15 B 87.0

11.0 Pellet H-5401 B-5105 Dense 105 -15 B 90.0

12.0 Pellet H-6401 B-6105 Dense 105 -15 B 90.0

13.1 Pellet H-7301 B-7301 Dense 102 -15 B 87.0

13.2 Pellet H-7301 Log.blue Dense 110 -15 B 95.0

13.3 Pellet H-7303 B-5401 Dense 105 -15 B 90.0

14.1 Pellet H-7301 B-7301 Dense 102 -15 B 87.0

14.2 Pellet H-7303 Logistik Dense 110 -15 B 95.0

14.3 Pellet H-7303 B-5401 Dense 105 -15 B 90.0

15.0 Pellet H-7109 B-7101 Fluid 118 -25 C 93.0

16.1 Pellet H-7208 B-7201 Fluid 116 -25 C 91.0

16.2 Pellet H-7208 B-7202 Fluid 116 -25 C 91.0

17.1 Pellet H-6301 B-6301 Fluid 117 -25 C 92.0

17.2 Pellet H-6301 B-6301 Fluid 117 -25 C 92.0

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 44: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Basell Project Tasnee - Hostalen ACP Pag. 7 of 7

New

Building-

Room

New Tag

Number

New

Power

[kw]

UnitBuilding-

RoomItem

P

[kw]Enclo-sure Description Type Acoustic treatment or design LWA installed

LWA

relevant to the

neighbourhood

Basell Prelimary Information - For Information Only!

18.1 Powder H-5201 B-5201 Fluid 98 -5 A 93.0

18.2 Powder H-5209 B-5201 Fluid 98 -5 A 93.0

19.1 Powder H-5202 B-5201 Fluid 95 -5 A 90.0

20.0 Powder H-5201 B-5201 Fluid 94 -5 A 89.0

21.0 Powder H-5304 B-5301 Dense 90 -5 A 85.0

Attachment 10 Preliminary HDPE Noise sources list rev0a Mar 10 2005.xls 6/23/2005

Page 45: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

EIA TASNEE Annex 4 to Attachment 6 Electrical User List and Load Summary – LDPE

Page 46: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/Y

LDPE 400 KT/Y

AM

AM

AM

AM

AM

AM

AMIssue Description Prepared Approved Date

Client Ref.: Location: AL JUBAIL - KSATASNEEPlant:

Tasnee Identification Code

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

3276-NN-LN-002001

Sheet Seefooter Issue 08

CheckedVAE

This document is Tecnimont’s property, and cannot be used by others for any purpose, without prior written consent

27/03/2006MAT

02 ISSUED FOR DETAIL ENGINEERING

01 PRELIMINARY ISSUE

MAT BRA 03/07/2006

BRA 11/12/200603 REVISED AND ISSUED FOR DETAIL ENGINEERING MAT

BRA 2/2/2007

06 REVISED AND ISSUED FOR DETAIL ENGINEERING

04 REVISED AND ISSUED FOR DETAIL ENGINEERING MAT

MAT BRA 8/8/2007

05

ELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

07 REVISED AND ISSUED FOR DETAIL ENGINEERING MAT BRA 16/10/2007

08 FINAL ISSUE 14/12/2006

REVISED AND ISSUED FOR DETAIL ENGINEERING MAT BRA 19/04/2007

1 of 20

Page 47: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/Y

LDPE 400 KT/YClient Ref.: Location: AL JUBAIL - KSATASNEEPlant:

Tasnee Identification Code

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

3276-NN-LN-002001

Sheet Seefooter Issue 08

GENERAL DESCRIPTION(referring to indicative numbers of list columns)

1 UNITArea in which the user is located. Refer Doc. N° 3276-XXDG-002 general Layout HDPE/LDPE Plants

2Tag number of users.

3M = electrical motorsZ = electrical heatingQ = electrical power boards

4 DESCRIPTIONIt specifies the type of driven machine: pump, centrifugal compressor, resistance etc. The “PACKAGE” units are regarded as only oneload if they are ordered complete with electric power board and electric distribution system, and the relevant users must be in evidence with a “X”under column 28.

5 INSTALLATIONA = presentF = future

6 OPERATIONC = continuousD = intermittent (lower than 24 total monthly hours)R = stand by

7A DESIGN MARGINDesign margin for motors as Percentage of [rated power of the load divided by absorbed power - 1]

7B MACHINE ABSORBED POWERWhenever motors are referred to, the mechanical power input of driven machine is understood.Power required at motor shaft

8 MOTOR RATED POWER

9 MOTOR RATED CURRENT

USER ITEM

USER TYPE

3

2

2 of 20

Page 48: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/Y

LDPE 400 KT/YClient Ref.: Location: AL JUBAIL - KSATASNEEPlant:

Tasnee Identification Code

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

3276-NN-LN-002001

Sheet Seefooter Issue 08

10 STATIC LOAD RATED POWER

11 STATIC LOAD RATED CURRENT

12 RATED VOLTAGE

13 SINGLE PHASE LOAD

14 NUMBER OF POLES

15 EFFICIENCY@OPERATING

16 POWER FACTOR@OPERATING

17 RATED ACTIVE LOAD

18 RATED REACTIVE LOAD

19 CONSUMED ACTIVE LOAD

20 CONSUMED REACTIVE LOAD

21 RUN REVERSAL

22 CONTROL FROM PROCESS BOARDDetailed control will be indicated on Electrical/Instrumentation data sheets.

23 INTERLOCK FROM PROCESS BOARD

24 SIGNAL LIGHT ON PROCESS BOARDDetailed description of signal light will be indicated on Electrical/Instrumentation data sheets.

25 ESD SHUT DOWNDetailed description of satety shut down will be indicated on Electrical /Instrumentation data sheets.

3 of 20

Page 49: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/Y

LDPE 400 KT/YClient Ref.: Location: AL JUBAIL - KSATASNEEPlant:

Tasnee Identification Code

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

3276-NN-LN-002001

Sheet Seefooter Issue 08

26 AUTOMATIC STARTING OF STAND-BY MOTORIn case of stop, not operated by personnel, of motor running.

27 CONTINOUS DUTY REQUIRED(LOAD CATEGORY):COD “A”MOST CRITICAL LOAD: no service break is admitted in order to avoid danger to personnel and/or installations

and/or prolonged production stops. Special feeding apparatus such as no-break rotating or static system (U.P.S.) are needed.

COD. “B VERY CRITICAL LOAD: only short service breaks are tolerated in order to avoid danger to personneland/or installations and/or prolonged production stops.Automatic re-starting is needed. The re-starting time steps will be indicated in Reacceleration Scheme

COD. “C CRITICAL LOAD: as under point “B”, but with longer stopping possibility (> 9 secs. Based on restoration of supply from Emergency DG).The load can be manually started up again from the control board room.If control from control board room is not provided, automatic re-starting is needed.

COD. “DNORMAL LOAD: prolonged stops are tolerated, however such as to allow re-starting from local pushbutton station(at least 30 min.)

COD. “E LOAD WITHOUT ANY SPECIAL REQUIREMENT: it is generally referred to motors which do not operate continuouslyat maximum output and which can be stopped, in case of failure, for the whole time required for replacing parts of electrical installation.

28 PACKAGE POWER BOARDIt is necessary to specify, as remarks, the referring boards.

29 DATA ACCURACYIt indicates how the specified power value has been derived1 = from estimate2 = from tender3 = from order

30 LOCAL AMMETERIt is to be specified for process requirement.

31 FED FROM SWGR No.

32 FED FROM SWGR Bus

4 of 20

Page 50: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/Y

LDPE 400 KT/YClient Ref.: Location: AL JUBAIL - KSATASNEEPlant:

Tasnee Identification Code

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

3276-NN-LN-002001

Sheet Seefooter Issue 08

33 INSTALLED IN ZONEIt indicates hazardous area zone, gas group/temperature class.

34 NOTES

35 REVISIONIt indicates the number of revisions which modifies the data referring to single load.

5 of 20

Page 51: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

302 6E-0201A Q DEFROSTING SYSTEM N.A. 3

302 6EM- 0201A1 M AIR HANDLING UNIT (-5°C) FAN A C 74 0.23 0.40 1.27 0.40 6 0.64 0.71 0.63 0.62 0.36 0.36 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0201A2 M AIR HANDLING UNIT (-5°C) FAN A C 74 0.23 0.40 1.27 0.40 6 0.64 0.71 0.63 0.62 0.36 0.36 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0201A3 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

302 6EM- 0201A4 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

302 6EM- 0201A5 M AIR HANDLING UNIT (-5°C) PUMP N.A. 3

302 6E-0201B Q DEFROSTING SYSTEM N.A. 3

302 6EM- 0201B1 M AIR HANDLING UNIT (-5°C) FAN A R 74 0.23 0.40 1.27 0.40 6 0.64 0.71 0.63 0.62 0.36 0.36 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0201B2 M AIR HANDLING UNIT (-5°C) FAN A R 74 0.23 0.40 1.27 0.40 6 0.64 0.71 0.63 0.62 0.36 0.36 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0201B3 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

302 6EM- 0201B4 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

302 6EM- 0201B5 M AIR HANDLING UNIT (-5°C) PUMP N.A. 3

302 6E-0201C Q DEFROSTING SYSTEM N.A. 3

302 6EM- 0201C1 M AIR HANDLING UNIT (-5°C) FAN A R 74 0.23 0.40 1.27 0.40 6 0.64 0.71 0.63 0.62 0.36 0.36 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0201C2 M AIR HANDLING UNIT (-5°C) FAN A R 74 0.23 0.40 1.27 0.40 6 0.64 0.71 0.63 0.62 0.36 0.36 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0201C3 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

302 6EM- 0201C4 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

302 6EM- 0201C5 M AIR HANDLING UNIT (-5°C) PUMP N.A. 3

302 6KM- 0201A M REFRIGERATION SYSTEM COMPRESSOR A C 21 109.00 132.00 228.63 0.40 2 0.95 0.88 139.39 75.23 115.10 62.12 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6KM- 0201S M REFRIGERATION SYSTEM COMPRESSOR A R 21 109.00 132.00 228.63 0.40 2 0.95 0.88 139.39 75.23 115.10 62.12 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0201A M COOLING FLUID CIRCULATION PUMP (PRIMARY) A C 70 3.71 6.30 12.74 0.40 4 0.86 0.83 7.33 4.92 4.31 2.90 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0201S M COOLING FLUID CIRCULATION PUMP (PRIMARY) A R 70 3.71 6.30 12.74 0.40 4 0.86 0.83 7.33 4.92 4.31 2.90 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0205A M COOLING FLUID CIRCULATION PUMP (PRIMARY) A C 36 2.50 3.40 8.39 0.40 6 0.78 0.75 4.36 3.84 3.21 2.83 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0205S M COOLING FLUID CIRCULATION PUMP (PRIMARY) A R 36 2.50 3.40 8.39 0.40 6 0.78 0.75 4.36 3.84 3.21 2.83 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6EM- 0202A1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202A2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202B1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202B2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202C1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202C2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202D1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202D2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202E1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202E2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202F1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202F2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202G1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202G2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202H1 M AIR HANDLING UNIT (10°C) FAN A R 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

302 6EM- 0202H2 M AIR HANDLING UNIT (10°C) FAN A R 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X C 3 X 6-SW-614 A 1 IIC T4 6PK-0201 7

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

12/14/2007 6 of 20

Page 52: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

302 6PM- 0202A M COOLING FLUID SUPPLY PUMP (SECONDARY) A C 58 2.91 4.60 9.76 0.40 4 0.83 0.82 5.54 3.87 3.51 2.45 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0202S M COOLING FLUID SUPPLY PUMP (SECONDARY) A R 58 2.91 4.60 9.76 0.40 4 0.83 0.82 5.54 3.87 3.51 2.45 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0203A M COOLING FLUID SUPPLY PUMP (SECONDARY) A C 42 4.44 6.30 12.74 0.40 4 0.86 0.83 7.33 4.92 5.16 3.47 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0203S M COOLING FLUID SUPPLY PUMP (SECONDARY) A R 42 4.44 6.30 12.74 0.40 4 0.86 0.83 7.33 4.92 5.16 3.47 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0204A M DEFROSTING PUMP A C 50 1.73 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 2.22 1.66 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6PM- 0204S M DEFROSTING PUMP A R 50 1.73 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 2.22 1.66 X X X C 3 X 6-SW-614 A SAFE 6PK-0201 5

302 6EH- 0201A Z OIL HEATER A D 2.00 2.89 0.40 1 1 2.00 0.00 2.00 0.00 E 3 6-SW-614 A SAFE 6PK-0201 5

302 6EH- 0201S Z OIL HEATER A R 2.00 2.89 0.40 1 1 2.00 0.00 2.00 0.00 E 3 6-SW-614 A SAFE 6PK-0201 5

302 6EH- 0203 Z BRINE HEATER A D 10.00 14.43 0.40 1 1 10.00 0.00 10.00 0.00 E 3 6-SW-614 A SAFE 6PK-0201 5

210 6PM- 0301A M SOLVENT UNLOADING PUMP A D 45 1.73 2.50 4.77 0.40 4 0.88 0.86 2.84 1.69 1.97 1.17 X X X D 3 X 6-SW-611 A 2 IIB T4 6

210 6PM- 0301S M SOLVENT UNLOADING PUMP A R 45 1.73 2.50 4.77 0.40 4 0.88 0.86 2.84 1.69 1.97 1.17 X X X D 3 X 6-SW-611 B 2 IIB T4 6

302 6MM- 0302A Q PO STORAGE DOOR A C 134 0.64 1.50 3.00 0.40 0.85 0.85 1.76 1.09 0.75 0.47 X X X D 2 X 6-SW-613 A 1 IIC T4 7

210 6PM- 0302A M SOLVENT SUPPLY PUMP A C 25 10.00 12.50 22.56 0.40 2 0.91 0.88 13.75 7.42 11.00 5.94 X X X D 3 X 6-SW-611 A 2 IIB T4 6

210 6PM- 0302S M SOLVENT SUPPLY PUMP A R 25 10.00 12.50 22.56 0.40 2 0.91 0.88 13.75 7.42 11.00 5.94 X X X D 3 X 6-SW-611 B 2 IIB T4 6

210 6KM- 0320A M REFRIGERATION SYSTEM COMPRESSOR A C 82 9.50 17.30 33.01 0.40 4 0.89 0.85 19.44 12.05 10.67 6.62 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6KM- 0320S M REFRIGERATION SYSTEM COMPRESSOR A R 82 9.50 17.30 33.01 0.40 4 0.89 0.85 19.44 12.05 10.67 6.62 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6PM- 0320A M CHILLED WATER SUPPLY PUMP A C 49 1.75 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 2.24 1.68 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6PM- 0320S M CHILLED WATER SUPPLY PUMP A R 49 1.75 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 2.24 1.68 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6EM- 0320A1 M AIR HANDLING UNIT FAN MOTOR A C 94 0.67 1.30 3.47 0.40 6 0.72 0.75 1.81 1.59 0.93 0.82 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6EM- 0320S1 M AIR HANDLING UNIT FAN MOTOR A R 94 0.67 1.30 3.47 0.40 6 0.72 0.75 1.81 1.59 0.93 0.82 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6EM- 0320A2 M AIR HANDLING UNIT FAN MOTOR A C 94 0.67 1.30 3.47 0.40 6 0.72 0.75 1.81 1.59 0.93 0.82 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

210 6EM- 0320S2 M AIR HANDLING UNIT FAN MOTOR A R 94 0.67 1.30 3.47 0.40 6 0.72 0.75 1.81 1.59 0.93 0.82 X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-0320 5

240 6PM- 0340A M MODIFIER TRANSFER PUMP A D 59 0.82 1.30 2.81 0.40 4 0.82 0.81 1.58 1.14 0.99 0.72 X X X D 3 X 6-SW-611 A 2 IIB T4 6

240 6PM- 0340S M MODIFIER TRANSFER PUMP A R 59 0.82 1.30 2.81 0.40 4 0.82 0.81 1.58 1.14 0.99 0.72 X X X D 3 X 6-SW-611 B 2 IIB T4 6

240 6PM- 0341A M MODIFIER(PA) UNLOADING PUMP A D 77 3.55 6.30 12.69 0.40 4 0.89 0.81 7.12 5.15 4.01 2.90 X X X D 3 X 6-SW-611 A 2 IIB T4 6

240 6PM- 0341S M MODIFIER(PA) UNLOADING PUMP A R 77 3.55 6.30 12.69 0.40 4 0.89 0.81 7.12 5.15 4.01 2.90 X X X D 3 X 6-SW-611 B 2 IIB T4 6

230 6EH- 0401 Z ELECTRICAL HEATER FOR 6TK-0401 A D 4.00 17.39 0.23 X 1 1 4.00 0.00 4.00 0.00 D 3 6-SW-611 A 2 IIB T4 6

230 6PM- 0401A M CYLINDER LUBE OIL PUMP(PRIMARY) A D 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 A 2 IIB T4 4

230 6PM- 0401S M CYLINDER LUBE OIL PUMP(PRIMARY) A R 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 B 2 IIB T4 4

230 6EH- 0402 Z ELECTRICAL HEATER FOR 6TK-0402 A D 20.00 28.87 0.40 1 1 20.00 0.00 4.00 0.00 D 3 6-SW-611 B 2 IIB T4 7

230 6PM- 0402A M CYLINDER LUBE OIL PUMP(HYPER) A C 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 A 2 IIB T4 4

230 6PM- 0402S M CYLINDER LUBE OIL PUMP(HYPER) A R 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 B 2 IIB T4 4

230 6EH- 0403 Z ELECTRICAL HEATER FOR 6TK-0403 A D 4.00 17.39 0.23 X 1 1 4.00 0.00 4.00 0.00 D 3 6-SW-611 A 2 IIB T4 7

230 6PM- 0403A M COOLING OIL PUMP(HYPER) A D 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 A 2 IIB T4 4

230 6PM- 0403S M COOLING OIL PUMP(HYPER) A R 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 B 2 IIB T4 4

230 6PM- 0404A M LUBE OIL UNLOADING PUMP A D 150 0.30 0.75 1.75 0.40 2 0.72 0.86 1.04 0.62 0.42 0.25 X X X D 3 X 6-SW-611 A 2 IIB T4 6

230 6PM- 0404B M LUBE OIL UNLOADING PUMP A D 150 0.30 0.75 1.75 0.40 2 0.72 0.86 1.04 0.62 0.42 0.25 X X X D 3 X 6-SW-611 B 2 IIB T4 6

230 6PM- 0404C M LUBE OIL UNLOADING PUMP A D 150 0.30 0.75 1.75 0.40 2 0.72 0.86 1.04 0.62 0.42 0.25 X X X D 3 X 6-SW-611 A 2 IIB T4 6

230 6PM- 0404S Q LUBE OIL UNLOADING PUMP N.A. 5

230 6PM- 0405A M WASTE OIL PUMP A C 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 A 2 IIB T4 4

12/14/2007 7 of 20

Page 53: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

230 6PM- 0405S M WASTE OIL PUMP A R 267 0.30 1.10 2.94 0.40 6 0.72 0.75 1.53 1.35 0.42 0.37 X X X D 3 X 6-SW-611 B 2 IIB T4 4

220 6KM- 0601 M NITROGEN COMPRESSOR A C 25 110.00 138.00 246.16 0.40 4 0.95 0.85 144.96 89.84 115.55 71.61 X X X D 3 X 6-SW-613 A SAFE 6

220 6PM- 0602 M LUBE OIL PUMP A C 46 1.20 1.75 3.95 0.40 0.8 0.8 2.19 1.64 1.50 1.13 X X X D 3 X 6-SW-613 A SAFE 8

50 6EHKM-0601 Z SPACE HEATER FOR NITROGEN COMPRESSORMOTOR N.A. 3

6MM- 0901 M HYDRAULIC TOOLS N.A. 2

6MM- 0902 M HP PRESS. TESTING DEVICE N.A. 2

10 6MM- 0903 Q HP VALVE TESTING STATION 7

200 6KM- 1001A M REFRIGERATION SYSTEM COMPRESSOR A C 77 14.30 25.30 47.11 0.40 4 0.91 0.85 27.74 17.19 15.68 9.72 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1001 7

200 6KM- 1001S M REFRIGERATION SYSTEM COMPRESSOR A R 77 14.30 25.30 47.11 0.40 4 0.91 0.85 27.74 17.19 15.68 9.72 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1001 7

200 6KM- 1101A M REFRIGERATION SYSTEM COMPRESSOR A C 77 14.30 25.30 47.11 0.40 4 0.91 0.85 27.74 17.19 15.68 9.72 X X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1002 5

200 6KM- 1101S M REFRIGERATION SYSTEM COMPRESSOR A R 77 14.30 25.30 47.11 0.40 4 0.91 0.85 27.74 17.19 15.68 9.72 X X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1002 5

6MMX-1001A M STATIC MIXER N.A. 2

6MMX-1001B M STATIC MIXER N.A. 2

6MMX-1001C M STATIC MIXER N.A. 2

60 6PM- 1001A M PEROXIDE DOSING PUMP A C 42 13.00 18.50 36.68 0.40 4 0.91 0.8 20.33 15.25 14.29 10.71 X X X X D 3 X 6-SW-611 A 2 IIC T4 7

60 6PM- 1001S M PEROXIDE DOSING PUMP A R 42 13.00 18.50 36.68 0.40 4 0.91 0.8 20.33 15.25 14.29 10.71 X X X X D 3 X 6-SW-611 B 2 IIC T4 7

200 6EM- 1002A1 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X D 3 X 6-SW-611 A 1 IIC T4 6PK-1001 7

200 6EM- 1002S1 M AIR HANDLING UNIT (10°C) FAN A R 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X D 3 X 6-SW-611 B 1 IIC T4 6PK-1001 7

200 6EM- 1002A2 M AIR HANDLING UNIT (10°C) FAN A C 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X D 3 X 6-SW-611 A 1 IIC T4 6PK-1001 7

200 6EM- 1002S2 M AIR HANDLING UNIT (10°C) FAN A R 71 0.175 0.30 0.98 0.40 6 0.63 0.7 0.48 0.49 0.28 0.28 X X X D 3 X 6-SW-611 B 1 IIC T4 6PK-1001 7

200 6EM- 1002B1 M AIR HANDLING UNIT (10°C) FAN N.A. 3

200 6EM- 1002B2 M AIR HANDLING UNIT (10°C) FAN N.A. 3

200 6EM- 1002B3 M AIR HANDLING UNIT (10°C) FAN N.A. 3

200 6EM- 1002B4 M AIR HANDLING UNIT (10°C) FAN N.A. 3

200 6KM- 1002A M REFRIGERATION SYSTEM COMPRESSOR N..A. 3

200 6KM- 1002S M REFRIGERATION SYSTEM COMPRESSOR N..A. 3

60 6MMX-1002 M STATIC MIXER N.A. 2

60 6PM- 1002A M PEROXIDE DOSING PUMP A C 120 5.00 11.00 22.53 0.40 4 0.87 0.81 12.64 9.15 5.75 4.16 X X X X D 3 X 6-SW-611 A 2 IICT4 7

60 6PM- 1002B M PEROXIDE DOSING PUMP A C 120 5.00 11.00 22.53 0.40 4 0.87 0.81 12.64 9.15 5.75 4.16 X X X X D 3 X 6-SW-611 B 2 IICT4 7

60 6PM- 1002C M PEROXIDE DOSING PUMP A C 120 5.00 11.00 22.53 0.40 4 0.87 0.81 12.64 9.15 5.75 4.16 X X X X D 3 X 6-SW-611 A 2 IICT4 7

200 6E-1003A Q DEFROSTING SYSTEM N.A. 3

200 6EM- 1003A M AIR HANDLING UNIT (-5°C) FAN A C 25 0.480 0.60 1.83 0.40 6 0.64 0.74 0.94 0.85 0.75 0.68 X X X D 3 X 6-SW-611 A 1 IIC T3 6PK-1001 7

200 6EM- 1003S M AIR HANDLING UNIT (-5°C) FAN A R 25 0.480 0.60 1.83 0.40 6 0.64 0.74 0.94 0.85 0.75 0.68 X X X D 3 X 6-SW-611 B 1 IIC T3 6PK-1001 7

200 6EM- 1003S1 M AIR HANDLING UNIT (-5°C) FAN N.A. 5

200 6EM- 1003S2 M AIR HANDLING UNIT (-5°C) FAN N.A. 5

200 6EM- 1003A5 M AIR HANDLING UNIT (-5°C) PUMP N.A. 3

200 6EH- 1004 Z BRINE HEATER A C 10.00 14.43 0.40 1 1 10.00 0.00 4.00 0.00 D 3 6-SW-611 B 2 IIB T3 6PK-1001 7

200 6EM- 1003B1 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

200 6EM- 1003B2 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

200 6EM- 1003B3 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

12/14/2007 8 of 20

Page 54: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

200 6EM- 1003B4 M AIR HANDLING UNIT (-5°C) FAN N.A. 3

200 6EM- 1003B5 M AIR HANDLING UNIT (-5°C) PUMP N.A. 3

200 6PM- 1003A M PEROXIDE FEED PUMP A D 38 0.58 0.80 2.00 0.40 4 0.73 0.79 1.10 0.85 0.79 0.62 X X X D 3 X 6-SW-611 A 1 IIC T4 7

200 6PM- 1003B M PEROXIDE FEED PUMP A R 38 0.58 0.80 2.00 0.40 4 0.73 0.79 1.10 0.85 0.79 0.62 X X X D 3 X 6-SW-611 B 1 IIC T4 7

200 6PM- 1003C M PEROXIDE FEED PUMP A D 38 0.58 0.80 2.00 0.40 4 0.73 0.79 1.10 0.85 0.79 0.62 X X X D 3 X 6-SW-611 A 1 IIC T4 7

200 6PM- 1003D M PEROXIDE FEED PUMP A D 38 0.58 0.80 2.00 0.40 4 0.73 0.79 1.10 0.85 0.79 0.62 X X X D 3 X 6-SW-611 B 1 IIC T4 7

200 6PM- 1003S1 M PEROXIDE FEED PUMP A D 38 0.58 0.80 2.00 0.40 4 0.73 0.79 1.10 0.85 0.79 0.62 X X X D 3 X 6-SW-611 A 1 IIC T4 7

200 6PM- 1003S2 M PEROXIDE FEED PUMP A R 38 0.58 0.80 2.00 0.40 4 0.73 0.79 1.10 0.85 0.79 0.62 X X X D 3 X 6-SW-611 B 1 IIC T4 7

60 6PM- 1004 M SOLVENT FLUSHING PUMP A C 42 13.00 18.50 36.68 0.40 4 0.91 0.8 20.33 15.25 14.29 10.71 X X X D 3 X 6-SW-611 A 2 IIC T4 7

60 6MP- 1005 M SLOP TANK PUMP N.A. 2

200 6PM- 1006A M COOLING FLUID CIRCULATION PUMP (PRIMARY) A C 114 0.84 1.80 4.22 0.40 4 0.77 0.8 2.34 1.75 1.09 0.82 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1001 5

200 6PM- 1006S M COOLING FLUID CIRCULATION PUMP (PRIMARY) A R 114 0.84 1.80 4.22 0.40 4 0.77 0.8 2.34 1.75 1.09 0.82 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1001 5

200 6PM- 1007A M COOLING FLUID SUPPLY PUMP(SECONDARY) A C 93 1.35 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 1.73 1.30 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1001 5

200 6PM- 1007S M COOLING FLUID SUPPLY PUMP (SECONDARY) A R 93 1.35 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 1.73 1.30 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1001 5

200 6PM- 1008A M COOLING FLUID CIRCULATION PUMP (PRIMARY) A C 120 0.82 1.80 4.22 0.40 4 0.77 0.8 2.34 1.75 1.06 0.80 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1002 6

200 6PM- 1008S M COOLING FLUID CIRCULATION PUMP (PRIMARY) A R 120 0.82 1.80 4.22 0.40 4 0.77 0.8 2.34 1.75 1.06 0.80 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1002 6

200 6PM- 1009A M COOLING FLUID SUPPLY PUMP (SECONDARY) A C 28 3.60 4.60 9.76 0.40 4 0.83 0.82 5.54 3.87 4.34 3.03 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1002 5

200 6PM- 1009S M COOLING FLUID SUPPLY PUMP (SECONDARY) A R 28 3.60 4.60 9.76 0.40 4 0.83 0.82 5.54 3.87 4.34 3.03 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1002 5

20 6PM- 1101A M HYDRAULIC OIL CIRCULATION PUMP A C 25 2.40 3.00 6.04 0.40 4 0.85 0.84 3.52 2.27 2.81 1.82 X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1101 7

10 6PM- 1101S M HYDRAULIC OIL CIRCULATION PUMP N.A. 3

20 6EH- 1102 Z ELECTRICAL HEATER FOR 6V-1101 A C 3.00 4.33 0.40 1 1 3.00 0.00 3.00 0.00 x x x E 3 6-SW-612 A 2 IIB T3 6PK-1101 7

20 6PM- 1102A M HYDRAULIC OIL PRESSURE PUMP A C 22 45.00 55.00 97.28 0.40 4 0.94 0.87 58.64 33.23 47.97 27.19 X X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-1101 7

20 6PM- 1102S M HYDRAULIC OIL PRESSURE PUMP A R 22 45.00 55.00 97.28 0.40 4 0.94 0.87 58.64 33.23 47.97 27.19 X X X X C 3 X 6-SW-614 A 2 IIB T3 6PK-1101 7

200 6PM- 1010A M COOLING FLUID SUPPLY PUMP A C 76 1.48 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 1.90 1.42 X X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1001 5

200 6PM- 1010S M COOLING FLUID SUPPLY PUMP A R 76 1.48 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 1.90 1.42 X X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1001 5

200 6PM- 1011A M COOLING FLUID SUPPLY PUMP A C 88 1.38 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 1.77 1.33 X X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1001 5

200 6PM- 1011S M COOLING FLUID SUPPLY PUMP A R 88 1.38 2.60 6.01 0.40 4 0.78 0.8 3.33 2.50 1.77 1.33 X X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1001 5

40 6PM- 1106A M OILY WATER TRANSFER PUMP N.A. 4

40 6PM- 1106S M OILY WATER TRANSFER PUMP N.A. 4

50 6PM- 1106A M WASTE WATER BASIN PUMP A C 51 3.70 5.60 10.57 0.40 2 0.9 0.85 6.22 3.86 4.11 2.55 X X X D 2 X 6-SW-612 A 1 IIB T3 7

50 6PM- 1106S M WASTE WATER BASIN PUMP A R 51 3.70 5.60 10.57 0.40 2 0.9 0.85 6.22 3.86 4.11 2.55 X X X D 2 X 6-SW-612 B 1 IIB T3 7

10 6HO- 1201 Q OVERHEAD TRAVELLING CRANE FOR 6K-1201/1202 A D 22.00 25.00 48.82 0.40 0.88 0.84 28.41 18.35 25.00 16.15 E 2 6-SW-612 B 2 IIB T3 7

10 6GM- 1201 M BARRING GEAR FOR 6K-1201 A R 25 4.00 5.00 8.91 0.40 12 0.9 0.9 5.56 2.69 4.44 2.15 X X X X E 3 X 6-SW-612 A 2 IIB T3 6PK-1201 6

10 6EH- 1203 Z CYLINDER LUBRICATOR HEAT TANK HEATER 6

10 6KM- 1201 M BOOSTER / PRIMARY COMPRESSOR A C 10 6880.00 7600.00 502.63 10.00 20 0.97 0.9 7835.05 3794.69 7092.78 3435.19 X X X X D 3 X 6-SW-600B A 2 IIB T3 6PK-1201 6

10 6EH- 1204 Z SPACE HEATER FOR BOOSTER / PRIMARYCOMPRESSOR MOTOR A D 2.00 2.89 0.40 1 1 2.00 0.00 2.00 0.00 E 3 6-SW-600B A 2 IIB T3 6PK-1201 5

10 6EHKM-1201 B Z SPACE HEATER FOR BOOSTER / PRIMARYCOMPRESSOR MOTOR N.A. 3

10 6MM- 1201 M HYDROCOM HYDRAULIC UNIT A R 11 2.70 3.00 6.68 0.40 4 0.79 0.82 3.80 2.65 3.42 2.39 X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1201 8

10 6PM- 1201A M WASTE OIL PUMP FOR 6K-1201 A C 57 1.40 2.20 5.66 0.40 8 0.8 0.7 2.75 2.80 1.75 1.78 X X X D 3 X 6-SW-612 A 2 IIB T3 7

10 6PM- 1201S M WASTE OIL PUMP FOR 6K-1201 A R 57 1.40 2.20 5.66 0.40 8 0.8 0.7 2.75 2.80 1.75 1.78 X X X D 3 X 6-SW-612 B 2 IIB T3 7

12/14/2007 9 of 20

Page 55: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

10 6GM- 1202 M BARRING GEAR FOR 6K-1202 A C 33 16.00 21.30 40.67 0.40 6 0.9 0.84 23.67 15.29 17.78 11.48 X X X X E 3 X 6-SW-612 A 2 IIB T3 6PK-1202 8

10 6KM- 1202 M HYPER COMPRESSOR A C 11 24810.00 27500.00 1621.16 10.00 36 0.98 1 28078.42 0.00 25331.84 0.00 X X X X D 3 X 6-SW-600B A 2 IIB T3 6PK-1202 6

10 6EH- 1215 Z SPACE HEATER FOR HYPER COMPRESSORMOTOR A D 4.00 1.80 0.40 1 1 4.00 0.00 4.00 0.00 E 3 6-SW-600B A 2 IIB T3 6PK-1202 6

10 6MM- 1202 M JACKING OIL UNIT FOR 6K-1202 A C 14 2.80 3.20 7.43 0.40 6 0.84 0.74 3.81 3.46 3.33 3.03 X X X D 3 X 6-SW-612 B 2 IIB T3 6PK-1202 8

10 6PM- 1202A M WASTE OIL PUMP FOR 6K-1202 A C 57 1.40 2.20 5.66 0.40 8 0.8 0.7 2.75 2.80 1.75 1.78 X X X D 3 X 6-SW-612 A 2 IIB T3 7

10 6PM- 1202S M WASTE OIL PUMP FOR 6K-1202 A R 57 1.40 2.20 5.66 0.40 8 0.8 0.7 2.75 2.80 1.75 1.78 X X X D 3 X 6-SW-612 B 2 IIB T3 7

10 6PM- 1203A M WASTE OIL PUMP FOR 6V-1203 A C 36 1.10 1.50 5.33 0.40 8 0.77 0.53 1.96 3.13 1.43 2.29 X X X D 3 X 6-SW-612 A 2 IIB T3 7

10 6PM- 1203S M WASTE OIL PUMP FOR 6 V 1203 N.A. 4

10 6PM- 1204 M CYLINDER LUBRICATOR CONSOLE A C 25 0.44 0.55 1.27 0.40 4 0.78 0.8 0.71 0.53 0.56 0.42 X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1201 6

10 6PM- 1205A M ELECTRICAL LUBE OIL PUMP A C 25 28.00 35.00 67.70 0.40 6 0.91 0.82 38.46 26.85 30.77 21.48 X X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1201 6

10 6PM- 1205S M ELECTRICAL LUBE OIL PUMP A R 25 28.00 35.00 67.70 0.40 6 0.91 0.82 38.46 26.85 30.77 21.48 X X X X D 3 X 6-SW-612 B 2 IIB T3 6PK-1201 6

10 6PM- 1206 M CYLINDER LUBRICATION PUMP UNIT FOR 6K-1202 A C 42 8.80 12.50 24.12 0.40 4 0.88 0.85 14.20 8.80 10.00 6.20 X X X D 3 X 6-SW-612 B 2 IIB T3 6PK-1202 8

10 6PM- 1207A M LUBE OIL PUMP FOR 6K-1202 A C 15 60.00 69.00 122.95 0.40 6 0.95 0.85 72.40 44.87 62.96 39.02 X X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1202 8

10 6PM- 1207S M LUBE OIL PUMP FOR 6K-1202 A R 15 60.00 69.00 122.95 0.40 6 0.95 0.85 72.40 44.87 62.96 39.02 X X X X D 3 X 6-SW-612 B 2 IIB T3 6PK-1202 8

10 6PM- 1208A M COOLING OIL PUMP FOR 6K-1202 A C 15 31.30 36.00 64.36 0.40 4 0.93 0.87 38.79 21.99 33.73 19.11 X X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1202 8

10 6PM- 1208S M COOLING OIL PUMP FOR 6K-1202 A R 15 31.30 36.00 64.71 0.40 4 0.92 0.87 39.00 22.10 33.91 19.22 X X X X D 3 X 6-SW-612 B 2 IIB T3 6PK-1202 8

10 6PM- 1209 M HYDROJACKING OIL PUMP FOR 6KM-1202 A D 10 2.00 2.20 4.73 0.40 4 0.8 0.84 2.75 1.78 2.50 1.61 X X X 3 X 6-SW-612 A 2 IIB T3 6PK-1202 8

10 6PM- 1210A M MODIFIER (PA) DOSING PUMP A C 45 3.80 5.50 11.12 0.40 4 0.86 0.83 6.40 4.30 4.42 2.97 X X X X D 3 X 6-VFD-612-1 A 2 IIB T4 VFD 5

10 6PM- 1210S M MODIFIER (PA) DOSING PUMP A R 45 3.80 5.50 11.12 0.40 4 0.86 0.83 6.40 4.30 4.42 2.97 X X X X D 3 X 6-VFD-612-2 A 2 IIB T4 VFD 5

10 6PM- 1212 M WASTE OIL DRAIN PUMP A C 56 0.16 0.25 1.00 0.40 8 0.6 0.6 0.42 0.56 0.27 0.36 X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1201 8

10 6PM- 1214 M JACKING OIL PUMP A C 25 1.76 2.20 5.68 0.40 6 0.81 0.69 2.72 2.85 2.17 2.28 X X X D 3 X 6-SW-612 A 2 IIB T3 6PK-1201 8

10 6EH- 1201 Z LUBE OIL ELECTRIC HEATER A C 7.50 10.83 0.40 1 1 7.50 0.00 7.50 0.00 D 3 6-SW-612 A 2 IIB T3 6PK-1201 7

10 6EH- 1203 Z CYLINDER LUBRICATOR DAYTANK ELECTRICHEATER A C 2.00 2.89 0.40 X 1 1 2.00 0.00 2.00 0.00 D 3 6-SW-612 A 2 IIB T3 6PK-1201 7

10 6EH- 1211 Z CYLINDER LUB. OIL ELECTRICAL HEATER A C 2.40 3.46 0.40 1 1 2.40 0.00 2.40 0.00 D 3 6-SW-612 B 2 IIB T3 6PK-1202 7

10 6EH- 1212 Z MOTION WORK COOLING OIL ELECTRICALHEATER A D 9.00 12.99 0.40 1 1 9.00 0.00 9.00 0.00 D 3 6-SW-612 B 2 IIB T3 6PK-1202 7

10 6EH- 1213 Z CYLINDER COOLING & FLUSHING OIL HEATER A D 9.00 12.99 0.40 1 1 9.00 0.00 9.00 0.00 D 3 6-SW-612 B 2 IIB T3 6PK-1202 7

10 6EH- 1214A Z CYLINDER LUBRICATION AIR HEATER A C 1.00 4.35 0.23 X 1 1 1.00 0.00 1.00 0.00 D 3 6-SW-612 A 2 IIB T3 6PK-1202 7

10 6EH- 1214B Z CYLINDER LUBRICATION AIR HEATER A C 1.00 4.35 0.23 X 1 1 1.00 0.00 1.00 0.00 D 3 6-SW-612 B 2 IIB T3 6PK-1202 7

10 6EH- 1215 Z CYLINDER LUBRICATION HEATER 6

10 6EH- 1216 Z HEATER FOR CYLINDER LUBRICATION PIPETRACE A C 3.00 13.00 0.40 1 1 3.00 0.00 3.00 0.00 D 3 6-DB-645 A 2 IIB T3 6PK-1202 7

20 6PM- 1301A M REACTOR BLOW DOWN CIRCULATION PUMP A C 24 72.40 90.00 152.10 0.40 2 0.95 0.9 94.84 45.93 76.29 45.93 X X X D 3 X 6-SW-612 A 2 IIB T3 7

M SAFETY SHOWER PUMP A C 2 IIB T3 3

20 6HO- 1301A Q HOIST FOR T-EMERGENCY VALVE 6

20 6HO- 1301B Q HOIST FOR T-EMERGENCY VALVE 6

20 6HO- 1302 Q CRANE FOR POLYMEIRZATION A D 7.00 11.00 19.60 0.40 0.9 0.9 12.22 5.92 7.78 3.77 E 2 6-SW-612 A 2 IIB T3 7

20 6HO- 1401 Q HOIST FOR XV 40101 6

20 6HO- 1402 Q HOIST FOR XV 40102 6

40 6HO- 1403 Q HOIST FOR XV 40301 6

40 6HO- 1404 Q HOIST FOR XV 50103 6

30 6PM- 1601A M WAXES PUMP A C 120 1.00 2.20 4.35 0.40 4 0.86 0.85 2.56 1.59 1.16 0.72 X X X D 3 X 6-SW-611 A 2 IIB T3 4

12/14/2007 10 of 20

Page 56: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

30 6PM- 1601S M WAXES PUMP N.A. 4

30 6PM- 1602A M OILY WAX BLOW DOWN PUMP A C 88 0.40 0.75 2.85 0.40 8 0.72 0.53 1.05 1.67 0.56 0.89 X X X D 3 X 6-SW-611 A 2 IIB T3 4

30 6PM- 1602S M OILY WAX BLOW DOWN PUMP A R 88 0.40 0.75 2.85 0.40 8 0.72 0.53 1.05 1.67 0.56 0.89 X X X D 3 X 6-SW-611 B 2 IIB T3 4

40 6PM- 1603A M WAXES BLOW DOWN PUMP A C 120 1.00 2.20 4.35 0.40 4 0.86 0.85 2.56 1.59 1.16 0.72 X X X D 3 X 6-SW-612 A 2 IIB T3 4

40 6PM- 1603S M WAXES BLOW DOWN PUMP N.A. 4

30 6ABM-1701 M EXHAUST FAN UNDER 6V-1716 A D 23 0.30 0.37 0.79 0.40 2 0.92 0.74 0.40 0.37 0.33 0.30 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1704 6

30 6EXM-1701 M MAIN EXTRUDER A C 26 3500.00 4400 1013.72 3.10 4 0.94 0.86 4680.85 2777.45 3723.40 2209.34 X X X X D 3 X 6-VFD-602 A 2 IIB T3 6PK-1701, VFD (BYPKG. VENDOR) 6

30 6EH- 1701 Z SPACE HEATER FOR MAIN EXTRUDER MOTOR A D 1.20 5.22 0.23 X 1 1 1.20 0.00 1.20 0.00 E 3 6-DB-631 A 2 IIB T3 6PK-1701 7

30 M MAIN EXTRUDER MOTOR LUB. OIL PUMP 6

30 M MAIN EXTRUDER MOTOR LUB. OIL PUMP 6

30 6HO- 1701 Q HOIST FOR MAIN EXTRUDER GEAR BOX COVER 2 IIB T3 TAG N° CHANGED TO6HO-1704B 7

30 Z GEAR BOX HEATER (RIGHT) N.A. 3

30 6MXM-1701A M ADDITIVE MELT AGITATOR A C 15 1.30 1.50 3.47 0.40 4 0.78 0.8 1.92 1.44 1.67 1.25 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6MXM-1701B M ADDITIVE MELT AGITATOR A C 15 1.30 1.50 3.47 0.40 4 0.78 0.8 1.92 1.44 1.67 1.25 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 6

30 6PM- 1701A M DOSING PUMP A C 111 1.50 3.17 7.15 0.40 4 0.8 0.8 3.96 2.97 1.88 1.41 X X X D 3 X 6-VFD-611-1 A 2 IIB T3 6PK-1701, VFD BYPKG VENDOR 6

30 6PM- 1701B M DOSING PUMP A C 111 1.50 3.17 7.15 0.40 4 0.8 0.8 3.96 2.97 1.88 1.41 X X X D 3 X 6-VFD-611-2 A 2 IIB T3 6PK-1701, VFD BYPKG VENDOR 6

30 6RFM-1701 M ROTARY FEEDER 6Z-1707 A C 17 0.47 0.55 1.13 0.40 0.87 0.81 0.63 0.46 0.54 0.39 X X X D 3 X 6-SW-611 A 2 IIB T3+22 6PK-1701 8

30 6ABM-1702 Q EXHAUST FAN FOR 6Z-1706 A D 23 0.30 0.37 0.82 0.40 4 0.79 0.82 0.47 0.33 0.38 0.27 X X X D 3 X 6-SW-611 B 2 IIB T3 +22 6PK-1701 6

30 6EXM-1702 M SATELLITE EXTRUDER (MASTERBATCH) A C 67 90.00 150 237.56 0.40 4 0.93 0.98 161.29 32.75 96.77 19.65 X X X D 2 X 6-VFD-611-3 A 2 IIB T3 +22

6PK-1701, VFD BYPKG VENDOR 3

30 6HO- 1702 Q HOIST FOR EXTRUDER PELLETIZER A D 10.10 15.00 29.62 0.40 0.86 0.85 17.44 10.81 11.74 7.28 E 2 6-SW-611 B 2 IIB T3 7

30 Q MASTERBATCH DOSING LIFTING DEVICE 6

30 6ABM-1703 M MASTERBATCH DOSING EXHAUST FAN A C 83 0.30 0.55 1.29 0.40 0.75 0.82 0.73 0.51 0.40 0.28 X X X D 2 X 6-SW-611 A 2 IIB T3 +22 6PK-1701 6

30 M MASTERBATCH DOSING SCREW 6

30 6PM- 1702A M LUBRICATING OIL PUMP (MAIN GEAR BOX) A C 85 24.00 44.40 82.93 0.40 4 0.92 0.84 48.26 31.17 26.09 16.85 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6PM- 1702S M LUBRICATING OIL PUMP (MAIN GEAR BOX) A R 85 24.00 44.40 82.93 0.40 4 0.92 0.84 48.26 31.17 26.09 16.85 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 6

30 6PM- 1703A M EXTRUDER DRIVE BEARING OIL LUBRICATIONPUMP-1 A C 25 0.60 0.75 1.92 0.40 4 0.73 0.77 1.02 0.85 0.82 0.68 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6PM- 1703S M EXTRUDER DRIVE BEARING OILLUBRICATIONPUMP-2 A R 25 0.60 0.75 1.92 0.40 4 0.73 0.77 1.02 0.85 0.82 0.68 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 6

30 M FAN MOTOR DOSING SYSTEM 6

30 6EH- 1703 Z HEATING BEARING LUBE OIL UNIT A D 0.80 3.48 0.23 X 1 1 0.00 0.00 0.00 0.00 D 3 6-SW-611 B 2 IIB T3 6PK-1701 6

30 6HO- 1703 Q ELECT. HOIST FOR EXTRUDER SCREW 6EX-1701 A D 5.40 7.00 13.82 0.40 0.86 0.85 8.14 5.04 6.28 3.89 E 2 6-SW-611 A 2 IIB T3 7

30 6HO- 1703B Q ELECT. HOIST FOR EXTRUDER SCREW 6EX-1701 A D N..A. 5

30 6HO- 1703C Q ELECT. HOIST FOR EXTRUDER SCREW 6EX-1701 A D N..A. 5

30 6MM- 1703 M GRANULATOR A C 43 280.00 400 396.20 0.69 4 0.96 0.88 416.67 224.89 291.67 157.42 X X X D 3 X 6-VFD-614 A 2 IIB T3 6PK-1701, VFD (BYPKG. VENDOR) 8

30 6EHMM-1703 Z SPACE HEATER FOR GRANULATOR MOTOR A D 0.70 3.04 0.23 X 1 1 0.70 0.00 0.70 0.00 E 3 6-VFD-614 A 2 IIB T3 6PK-1701 6

30 6ABM-1704 M NOISE HOOD FAN FOR MAIN GEAR A C 80 0.15 0.27 0.84 0.40 4 0.6 0.77 0.45 0.37 0.25 0.21 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 6

30 6EH- 1704A-H Z MAIN GEAR BOX HEATER (LEFT AND RIGHT) A C 16.00 23.09 0.40 1 1 16.00 0.00 16.00 0.00 D 3 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6HO- 1704A Q ELECT. HOIST FOR MOTOR AND GEAR REDUCER6EX-1701 A D 10.10 15.00 29.62 0.40 0.86 0.85 17.44 10.81 11.74 7.28 E 2 6-SW-611 A 2 IIB T3 7

30 6HO- 1704B Q HOIST FOR MAIN EXTRUDER GEAR BOX COVER A D 5.40 7.00 13.82 0.40 0.86 0.85 8.14 5.04 6.28 3.89 E 2 6-SW-611 A 2 IIB T3 7

30 6HO- 1704B Q ELECT. HOIST FOR MOTOR AND GEAR REDUCER6EX-1701 N..A. 5

30 6PM- 1704A M LIQUID RING COMPRESSOR A C 50 26.00 39.10 71.70 0.40 4 0.93 0.85 42.22 26.17 28.08 17.40 X X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1704 6

12/14/2007 11 of 20

Page 57: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

30 6PM- 1704S M LIQUID RING COMPRESSOR A R 50 26.00 39.10 71.70 0.40 4 0.93 0.85 42.22 26.17 28.08 17.40 X X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1704 6

30 6ABM-1705 M NOISE HOOD FAN FOR MAIN GEAR A C 41 0.41 0.58 1.49 0.40 4 0.71 0.79 0.82 0.63 0.58 0.45 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6EH- 1705 Z SATELLITE GEAR BOX HEATER A C 1.05 1.52 0.40 1 1 1.05 0.00 1.05 0.00 D 3 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6HO- 1705A Q ELECTRICAL HOIST ADDITIVES A D 2.75 5.00 11.88 0.40 0.75 0.81 6.67 4.83 3.67 2.65 E 2 6-SW-611 A 2 IIB T3 7

30 6HO- 1705B Q ELECTRICAL HOIST ADDITIVES A D 2.75 5.00 11.88 0.40 0.75 0.81 6.67 4.83 3.67 2.65 E 2 6-SW-611 B 2 IIB T3 7

30 6PM- 1705A M HOT WATER CIRCULATION PUMP A C 13 15.00 17.00 29.63 0.40 2 0.91 0.91 18.68 8.51 16.48 7.51 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 8

30 6PM- 1705S M HOT WATER CIRCULATION PUMP A R 13 15.00 17.00 29.63 0.40 2 0.91 0.91 18.68 8.51 16.48 7.51 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 8

30 6HO- 1706 Q BAG DISCHARGE STATION LIFTING DEVICE A C 2.79 5.00 15.13 0.40 0.53 0.9 0.00 0.00 0.00 0.00 D 3 6-SW-611 A 2 IIB T3 6PK-1701 7

30 6Z-1706B Q BAG DISCHARGE STATION LIFTING DEVICE 6

30 M WATER COOLING UNIT N.A. 3

30 M WATER COOLING UNIT N.A. 3

30 6PM- 1706 M SATELLITE EXTRUDER LUB. OIL PUMP A C 23 2.80 3.45 7.59 0.40 4 0.8 0.82 4.31 3.01 3.50 2.44 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6PM- 1707 M HYDRAULIC DOCKING SYSTEM MOTOR FORGRANULATOR (CLAMPING & MOVING) A C 62 6.80 11.00 20.28 0.40 4 0.87 0.9 12.64 6.12 7.82 3.79 X X X D 3 X 6-SW-611 B 2 IIB T3 +

22 6PK-1701 6

30 6ABM-1707 M FAN FOR EXTRUDER MOTOR A C 25 16.00 20.00 39.22 0.40 4 0.92 0.8 21.74 16.30 17.39 13.04 X X X D 3 X 6-VFD-602 A 2 IIB T3 6PK-1701 8

30 6ZM- 1707 M MOTOR FOR DOSING BAG DISCHARGE STATION A C 35 0.20 0.27 0.53 0.40 4 0.92 0.8 0.29 0.22 0.22 0.16 X X X D 2 X 6-SW-611 B 2 IIB T3 6PK-1701 6

30 6PM- 1709 M HYDRAULIC KNIFE ADJUSTMENT MOTOR FORGRANULATOR A C 43 1.05 1.50 3.51 0.40 4 0.77 0.8 1.95 1.46 1.36 1.02 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 7

30 6WM- 1710B M PADDLE DRIVE A C 120 0.20 0.44 1.13 0.40 4 0.7 0.8 0.63 0.47 0.29 0.21 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 7

30 6WM- 1710A M LOSS IN WEIGHT FEEDER A C 350 0.20 0.90 2.22 0.40 4 0.75 0.78 1.20 0.96 0.27 0.21 X X X D 3 X 6-VFD-611-4 A 2 IIB T3 6PK-1701, VFD BYPKG VENDOR 7

30 M COOLING WATER PUMP N.A. 3

30 M HYDRAULIC UNIT PUMP FOR GRANULATOR 6

30 Q NOISE HOOD LIGHT SUPPLY 6

30 6PM- 1710 M PUMP FOR HYDRAULIC UNIT A C 29 8.50 11.00 20.28 0.40 4 0.87 0.9 12.64 6.12 9.77 4.73 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 7

30 6PM- 1711 M PUMP FOR HYDRAULIC UNIT A C 25 6.00 7.50 14.32 0.40 4 0.84 0.9 8.93 4.32 7.14 3.46 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 7

50 6EM- 1801A M FLASH STEAM CONDENSER A C 60 9.40 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.32 6.12 X X X D 3 X 6-SW-612 A SAFE 4

50 6EM- 1801B M FLASH STEAM CONDENSER A C 60 9.40 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.32 6.12 X X X D 3 X 6-SW-612 B SAFE 4

50 6EM- 1801C M FLASH STEAM CONDENSER A C 60 9.40 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.32 6.12 X X X D 3 X 6-SW-612 A SAFE 4

50 6EM- 1801D M FLASH STEAM CONDENSER A C 60 9.40 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.32 6.12 X X X D 3 X 6-SW-612 B SAFE 4

50 6MMX-1801 M MIXING AGITATOR FOR 6V 1806 N.A. 2

50 6PM- 1801A M LP HOT WATER CIRCULATION PUMP A C 19 1257.00 1500.00 73.84 13.80 4 0.96 0.89 1570.68 804.68 1316.23 674.32 X X X D 3 X 6-SW-600A A SAFE 4

50 6PM- 1801S M LP HOT WATER CIRCULATION PUMP A R 19 1257.00 1500.00 73.84 13.80 4 0.96 0.89 1570.68 804.68 1316.23 674.32 X X X D 3 X 6-SW-600A A SAFE 4

50 6EHPM-1801A Z SPACE HEATER FOR LP HOT WATERCIRCULATION PUMP MOTOR A D 0.546 2.37 0.23 X 1 1 0.55 0.00 0.55 0.00 E 3 6-SW-600A A SAFE 4

50 6EHPM-1801S Z SPACE HEATER FOR LP HOT WATERCIRCULATION PUMP MOTOR A D 0.546 2.37 0.23 X 1 1 0.55 0.00 0.55 0.00 E 3 6-SW-600A A SAFE 4

50 6HO- 1801A Q HOIST FOR MAINTENANCE OF 6P-1801A A D 4.30 7.00 13.82 0.40 0.86 0.85 8.14 5.04 5.00 3.10 E 2 6-SW-612 A 2 IIB T3 7

50 6HO- 1801S Q HOIST FOR MAINTENANCE OF 6P-1801S A D 4.30 7.00 13.82 0.40 0.86 0.85 8.14 5.04 5.00 3.10 E 2 6-SW-612 B 2 IIB T3 7

50 6EM- 1802A M WARM WATER COOLER A C 61 9.30 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.21 6.06 X X X D 3 X 6-SW-612 A SAFE 5

50 6EM- 1802B M WARM WATER COOLER A C 61 9.30 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.21 6.06 X X X D 3 X 6-SW-612 B SAFE 5

50 6EM- 1802C M WARM WATER COOLER A C 61 9.30 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.21 6.06 X X X D 3 X 6-SW-612 A SAFE 5

50 6EM- 1802D M WARM WATER COOLER A C 61 9.30 15.00 27.64 0.40 4 0.91 0.86 16.47 9.77 10.21 6.06 X X X D 3 X 6-SW-612 B SAFE 5

50 6PM- 1802A M MP HOT WATER CIRCULATION PUMP A C 23 974.00 1200.00 59.07 13.80 4 0.96 0.89 1256.54 643.75 1019.90 522.51 X X X D 3 X 6-SW-600A A SAFE 5

50 6EHPM-1802A Z SPACE HEATER FOR MP HOT WATERCIRCULATION PUMP MOTOR A D 0.546 2.37 0.23 X 1 1 0.55 0.00 0.55 0.00 E 3 6-SW-600A A SAFE 4

12/14/2007 12 of 20

Page 58: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

50 6PM- 1802S M MP HOT WATER CIRCULATION PUMP A R 23 974.00 1200.00 59.07 13.80 4 0.96 0.89 1256.54 643.75 1019.90 522.51 X X X D 3 X 6-SW-600A A SAFE 5

50 6EHPM-1802S Z SPACE HEATER FOR MP HOT WATERCIRCULATION PUMP MOTOR A D 0.546 2.37 0.23 X 1 1 0.55 0.00 0.55 0.00 E 3 6-SW-600A A SAFE 4

50 6HO- 1802A Q HOIST FOR MAINTENANCE OF 6P-1802A A D 4.30 7.00 13.82 0.40 0.86 0.85 8.14 5.04 5.00 3.10 E 2 6-SW-612 A SAFE 6

50 6HO- 1802S Q HOIST FOR MAINTENANCE OF 6P-1802S A D 4.30 7.00 13.82 0.40 0.86 0.85 8.14 5.04 5.00 3.10 E 2 6-SW-612 B SAFE 6

50 6HO- 1803 Q CRANE FOR PUMPS 6-SW-612 A DELETED 8

50 6EM- 1803A M LP STEAM CONDENSER FAN A C 45 25.50 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 27.27 18.33 X X X D 3 X 6-SW-612 A SAFE 5

50 6EM- 1803B M LP STEAM CONDENSER FAN A C 45 25.50 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 27.27 18.33 X X X D 3 X 6-SW-612 B SAFE 5

50 6EM- 1803C M LP STEAM CONDENSER FAN A C 45 25.50 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 27.27 18.33 X X X D 3 X 6-VFD-612-3 A SAFE VFD 5

50 6EM- 1803D M LP STEAM CONDENSER FAN A C 45 25.50 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 27.27 18.33 X X X D 3 X 6-VFD-612-4 A SAFE VFD 5

50 6EM- 1803E M LP STEAM CONDENSER FAN A C 45 25.50 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 27.27 18.33 X X X D 3 X 6-VFD-612-5 A SAFE VFD 5

50 6EM- 1803F M LP STEAM CONDENSER FAN A C 45 25.50 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 27.27 18.33 X X X D 3 X 6-VFD-612-6 A SAFE VFD 5

50 6MXM-1802 M MIXING AGITATOR FOR 6V 1809 A C 25 0.44 0.55 1.24 0.40 0.8 0.8 0.69 0.52 0.55 0.41 X X X D 2 X 6-SW-612 A SAFE 6PK-1801 6

50 6PM- 1803A M CONDENSATE FEED PUMP A C 15 80.00 92.00 155.48 0.40 2 0.95 0.9 96.94 46.95 84.30 40.83 X X X D 3 X 6-SW-612 A SAFE 6

50 6PM- 1803S M CONDENSATE FEED PUMP A R 15 80.00 92.00 155.48 0.40 2 0.95 0.9 96.94 46.95 84.30 40.83 X X X D 3 X 6-SW-612 B SAFE 6

50 6EM- 1804A M MP STEAM CONDENSER A C 37 27.00 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 28.88 19.41 X X X D 3 X 6-SW-612 A SAFE 5

50 6EM- 1804B M MP STEAM CONDENSER A C 37 27.00 37.00 68.82 0.40 6 0.94 0.83 39.57 26.59 28.88 19.41 X X X D 3 X 6-VFD-612-7 A SAFE VFD 5

50 6ME- 1804C M MP STEAM CONDENSER X X X N.A.

50 6ME- 1804D M MP STEAM CONDENSER X X X N.A.

50 6PM- 1804A M WARM WATER CIRCULATION PUMP A C 27 158.00 200.00 34.82 4.16 4 0.95 0.84 210.75 136.13 166.49 107.54 X X X D 3 X 6-SW-601 A SAFE 5

50 6EHPM-1804A Z SPACE HEATER FOR WARM WATERCIRCULATION PUMP MOTOR A D 0.12 0.52 0.23 X 1 1 0.12 0.00 0.12 0.00 E 3 6-SW-601 A SAFE 5

50 6PM- 1804S M WARM WATER CIRCULATION PUMP A R 27 158.00 200.00 34.82 4.16 4 0.95 0.84 210.75 136.13 166.49 107.54 X X X D 3 X 6-SW-601 B SAFE 5

50 6EHPM-1804S Z SPACE HEATER FOR WARM WATERCIRCULATION PUMP MOTOR A D 0.12 0.52 0.23 X 1 1 0.12 0.00 0.12 0.00 E 3 6-SW-601 B SAFE 5

50 6PM- 1805A M WARM WATER FEED PUMP N.A. 4

50 6PM- 1805S M WARM WATER FEED PUMP N.A. 4

50 6PM- 1806 M TRANSFER PUMP FOR HYDRAZINE N.A. 3

50 6PM- 1807A M DOSING PUMP FOR HYDRAZINE A C 25 0.60 0.75 2.09 0.40 4 0.69 0.75 1.09 0.96 0.87 0.77 X X X D 2 X 6-SW-612 A SAFE 6PK-1801 3

50 6PM- 1807B M DOSING PUMP FOR HYDRAZINE A C 25 0.60 0.75 2.09 0.40 4 0.69 0.75 1.09 0.96 0.87 0.77 X X X D 2 X 6-SW-612 B SAFE 6PK-1801 3

50 6PM- 1807C M DOSING PUMP FOR HYDRAZINE A C 25 0.60 0.75 2.09 0.40 4 0.69 0.75 1.09 0.96 0.87 0.77 X X X D 2 X 6-SW-612 A SAFE 6PK-1801 3

50 6PM- 1809A M DOSING PUMP FOR PHOSPHATE A C 25 0.88 1.10 3.07 0.40 4 0.69 0.75 1.59 1.41 1.28 1.12 X X X D 2 X 6-SW-612 A SAFE 6PK-1801 3

50 6PM- 1809B M DOSING PUMP FOR PHOSPHATE A C 25 0.88 1.10 3.07 0.40 4 0.69 0.75 1.59 1.41 1.28 1.12 X X X D 2 X 6-SW-612 B SAFE 6PK-1801 3

50 6PM- 1809C M DOSING PUMP FOR PHOSPHATE A C 25 0.88 1.10 3.07 0.40 4 0.69 0.75 1.59 1.41 1.28 1.12 X X X D 2 X 6-SW-612 A SAFE 6PK-1801 3

50 6PM- 1810A M COOLING MEDIUM CIRCULATION PUMP A C 65 80.00 132.00 228.63 0.40 2 0.95 0.88 139.39 75.23 84.48 45.60 X X X D 3 X 6-SW-612 A SAFE 4

50 6PM- 1810S M COOLING MEDIUM CIRCULATION PUMP A R 65 80.00 132.00 228.63 0.40 2 0.95 0.88 139.39 75.23 84.48 45.60 X X X D 3 X 6-SW-612 B SAFE 4

50 6PM- 1811 M DOSING PUMP FOR INHIBITOR A D 100 0.30 0.60 1.60 0.40 4 0.67 0.81 0.90 0.65 0.45 0.32 X X X E 3 X 6-SW-612 A SAFE 5

50 6EM- 1820A M AFTER COOLER HOT WATER COOLER A C 40 13.20 18.50 35.00 0.40 4 0.93 0.86 20.00 11.87 14.27 8.47 X X X D 3 X 6-SW-612 A SAFE 5

50 6EM- 1820B M AFTER COOLER HOT WATER COOLER A C 40 13.20 18.50 35.00 0.40 4 0.93 0.86 20.00 11.87 14.27 8.47 X X X D 3 X 6-SW-612 B SAFE 5

50 6PM- 1820A M AFTER COOLER HOT WATER CIRCULATION PUMP A C 28 117.00 150.00 259.23 0.40 4 0.96 0.87 156.25 88.55 121.88 69.07 X X X D 3 X 6-SW-612 A SAFE 5

50 6PM- 1820S M AFTER COOLER HOT WATER CIRCULATION PUMP A R 28 117.00 150.00 259.23 0.40 4 0.96 0.87 156.25 88.55 121.88 69.07 X X X D 3 X 6-SW-612 B SAFE 5

50 6PM- 1821 M DOSING PUMP FOR INHIBITOR A D 25 0.48 0.60 1.60 0.40 4 0.67 0.81 0.90 0.65 0.72 0.52 X X X E 3 X 6-SW-612 A SAFE 5

30 6ABM-1901A M SUCTION FAN A C 41 142.00 200.00 33.24 4.16 2 0.96 0.87 208.33 118.07 147.92 83.83 X X X D 3 X 6-SW-601 A 2 IIB T3 6PK-1701 8

12/14/2007 13 of 20

Page 59: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

30 6EHABM-1901A Z SPACE HEATER FOR SUCTION FAN MOTOR A D 0.50 2.17 0.23 X 1 1 0.50 0.00 0.50 0.00 E 3 6-SW-601 A 2 IIB T3 6PK-1701 8

30 6ABM-1901S M SUCTION FAN A R 41 142.00 200.00 33.24 4.16 2 0.96 0.87 208.33 118.07 147.92 83.83 X X X D 3 X 6-SW-601 B 2 IIB T3 6PK-1701 8

30 6EHABM-1901S Z SPACE HEATER FOR SUCTION FAN MOTOR A D 0.50 2.17 0.23 X 1 1 0.50 0.00 0.50 0.00 E 3 6-SW-601 B 2 IIB T3 6PK-1701 8

30 6FM- 1901 M PELLET WATER FINE SIEVE N.A. 5

30 6PM- 1901A M TRANSPORT WATER PUMP A C 23 134.00 165.00 275.65 0.40 4 0.96 0.9 171.88 83.24 139.58 67.60 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 6PM- 1901S M TRANSPORT WATER PUMP A R 23 134.00 165.00 275.65 0.40 4 0.96 0.9 171.88 83.24 139.58 67.60 X X X D 3 X 6-SW-611 B 2 IIB T3 6PK-1701 6

30 6SM- 1901 M PELLET DRYER A C 23 30.00 37.00 72.56 0.40 8 0.92 0.8 40.22 30.16 32.61 24.46 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

30 M PELLET DRYER EXHAUST FAN 6

30 Q MELT INDEX RHEOMETER 6

30 6HO- 1901 Q MANUAL HOIST/CHAIN BLOCK FOR GALA DRYERMAINTENANCE N..A. 5

30 6MM- 1902 M SAMPLING DEVICE N.A. 5

30 6PM- 1902 M WATER JET PUMP N.A. 5

30 6HO- 1902 Q MANUAL HOIST/CHAIN BLOCK FOR GENERALPURPOSE PLANT MAINTENANCE N..A. 5

30 6ABM-1903 M VENT GAS FAN FOR TK 1902 N.A. 5

30 6PM- 1910 M PH BUFFERING DOSING PUMP A C 50 0.14 0.21 0.62 0.40 4 0.7 0.7 0.30 0.31 0.20 0.20 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 7

30 6WM- 1910 M WEIGHING DEVICE / CORIOLIS FLOW METER A C 30 2.00 2.60 5.86 0.40 4 0.8 0.8 3.25 2.44 2.50 1.88 X X X D 3 X 6-SW-611 A 2 IIB T3 6PK-1701 6

220 6ABM-4201 M WASTE GAS FAN A C 71 146.60 250.00 432.06 0.40 4 0.96 0.87 260.42 147.58 152.71 86.54 X X X D 3 X 6-VFD-613-1 A 2 IIB T3 6PK-4201,VFD BYPKG. VENDOR 7

220 6EHABM-4201 Z SPACE HEATER FOR WASTE GAS FAN MOTOR N..A. 3

220 SCREW CONVEYOR N.A. 5

220 6RFM-4201 M FILTER ROTORY VALVE A C 23 0.30 0.37 1.08 0.40 4 0.69 0.72 0.54 0.52 0.43 0.42 X X X D 3 X 6-SW-613 B 2 IIB T3 6PK-4201 7

220 6ABM-4202 M COMBUSTION AIR FAN A C 33 16.50 22.00 38.02 0.40 2 0.93 0.9 23.71 11.48 17.78 8.61 X X X D 3 X 6-VFD-613-2 A 2 IIB T3 6PK-4201,VFD BYPKG. VENDOR 7

220 6ABM-4203 M HDPE WASTE GAS FAN A C 53 4.90 7.50 13.52 0.40 2 0.89 0.9 8.43 4.08 5.51 2.67 X X X D 3 X 6-VFD-613-3 A 2 IIB T3 6PK-4201,VFD BYPKG. VENDOR 7

220 6ABM-4204 M PURGE GAS FAN A C 23 15.00 18.50 32.04 0.40 2 0.93 0.9 19.98 9.68 16.20 7.85 X X X D 3 X 6-SW-613 B 2 IIB T3 6PK-4201 7

220 6SFM-4201 M FILTER SCREW CONVEYOR A C 50 0.50 0.75 2.06 0.40 4 0.75 0.7 1.00 1.02 0.67 0.68 X X X D 3 X 6-SW-613 B 2 IIB T3 6PK-4201 7

220 Q PLC CABINET IN FIELD AUXILIARY ROOM 6

220 6-42-TV-94200A/ Q MOTORISED VALVE WASTE GAS TREATMENT A C 4.00 4.00 9.02 0.40 0.8 0.8 5.00 3.75 5.00 3.75 D 1 6-SW-613 A 2 IIB T3 6PK-4201 7

301 6PM- 4901A M STORM/RAIN WATER PUMP A C 51 3.70 5.60 10.57 0.40 0.9 0.85 6.22 3.86 4.11 2.55 X X X D 2 X 6-SW-611 A 1 IIB T3 6

301 6PM- 4901S M STORM/RAIN WATER PUMP A R 51 3.70 5.60 10.57 0.40 0.9 0.85 6.22 3.86 4.11 2.55 X X X D 2 X 6-SW-611 B 1 IIB T3 6

90 6KM- 5101A M CONVEYING AIR COMPRESSOR A C 32 197.00 260.00 43.66 4.16 2 0.95 0.87 273.68 155.10 207.37 117.52 X X X D 3 X 6-SW-601 A SAFE 6PK-5130/31 4

90 6EHKM-5101A Z SPACE HEATER FOR CONVEYING AIRCOMPRESSOR MOTOR A D 0.25 1.09 0.23 X 1 1 0.25 0.00 0.25 0.00 E 3 6-SW-601 A SAFE 6PK-5130/31 4

90 6MKB-5101A1 M NOISE HOOD FAN FOR 6KM-5101A N.A. 4

90 6MKB-5101A2 M NOISE HOOD FAN FOR 6KM-5101A N.A. 4

90 6MKM-5101A M OIL DEMISTOR FOR 6K-5101A A C 83 0.30 0.55 1.53 0.40 2 0.7 0.74 0.79 0.71 0.43 0.39 X X X D 2 X 6-SW-613 A SAFE 6PK-5130/31 5

90 6KM- 5101S M CONVEYING AIR COMPRESSOR A R 32 197.00 260.00 43.66 4.16 2 0.95 0.87 273.68 155.10 207.37 117.52 X X X D 3 X 6-SW-601 B SAFE 6PK-5130/31 4

90 6EHKM-5101S Z SPACE HEATER FOR CONVEYING AIRCOMPRESSOR MOTOR A D 0.25 1.09 0.23 X 1 1 0.25 0.00 0.25 0.00 E 3 6-SW-601 B SAFE 6PK-5130/31 4

90 6MKB-5101S1 M NOISE HOOD FAN FOR 6KM-5101S N.A. 4

90 6MKB-5101S2 M NOISE HOOD FAN FOR 6KM-5101S N.A. 4

90 6MKM-5101S M OIL DEMISTOR FOR 6K-5101S A R 83 0.30 0.55 1.53 0.40 0.7 0.74 0.79 0.71 0.43 0.39 X X X D 2 X 6-SW-613 B SAFE 6PK-5130/31 7

90 6PM- 5101A M PUMP FOR WASHING WATER A C 12 9.80 11.00 21.73 0.40 4 0.87 0.84 12.64 8.17 11.26 7.28 X X X E 3 X 6-SW-613 A SAFE 8

90 6PM- 5101S M PUMP FOR WASHING WATER A R 12 9.80 11.00 21.73 0.40 4 0.87 0.84 12.64 8.17 11.26 7.28 X X X E 3 X 6-SW-613 B SAFE 8

12/14/2007 14 of 20

Page 60: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

30 6RFM-5101A M ROTARY FEEDER A C 26 1.90 2.40 5.57 0.40 4 0.8 0.78 3.01 2.41 2.38 1.91 X X X D 3 X 6-SW-611 A SAFE 6PK-5130/31 6

30 6RFM-5101S M ROTARY FEEDER 7

90 6KM- 5102A M DEGASSING AIR COMPRESSOR A C 20 125.00 150.00 265.01 0.40 4 0.95 0.86 157.89 93.69 131.58 78.07 X X X X X D 3 X 6-SW-613 A SAFE 6PK-5130/31 4

90 6KBM-5102A1 M NOISE HOOD FAN FOR 6KM-5102A N.A. 4

90 6KBM-5102A2 M NOISE HOOD FAN FOR 6KM-5102A N.A. 4

90 6EHKM-5102A Z SPACE HEATER FOR DEGASSING AIRCOMPRESSOR N.A. 4

90 6KM- 5102B M DEGASSING AIR COMPRESSOR A C 20 125.00 150.00 265.01 0.40 4 0.95 0.86 157.89 93.69 131.58 78.07 X X X X X D 3 X 6-SW-613 B SAFE 6PK-5130/31 4

90 6KBM-5102B1 M NOISE HOOD FAN FOR 6KM-5102B N.A. 4

90 6KBM-5102B2 M NOISE HOOD FAN FOR 6KM-5102B N.A. 4

90 6EHKM-5102B Z SPACE HEATER FOR DEGASSING AIRCOMPRESSOR N.A. 4

90 6KM- 5102C M DEGASSING AIR COMPRESSOR A C 20 125.00 150.00 265.01 0.40 4 0.95 0.86 157.89 93.69 131.58 78.07 X X X X X D 3 X 6-SW-613 A SAFE 6PK-5130/31 4

90 6KBM-5102C1 M NOISE HOOD FAN FOR 6KM-5102C N.A. 4

90 6KBM-5102C2 M NOISE HOOD FAN FOR 6KM-5102C N.A. 4

90 6EHKM-5102C Z SPACE HEATER FOR DEGASSING AIRCOMPRESSOR N.A. 4

90 6KM- 5102S M DEGASSING AIR COMPRESSOR A R 20 125.00 150.00 265.01 0.40 4 0.95 0.86 157.89 93.69 131.58 78.07 X X X X X D 3 X 6-SW-613 B SAFE 6PK-5130/31 5

90 6KBM-5102S1 M NOISE HOOD FAN FOR 6KM-5102S N.A. 4

90 6KBM-5102S2 M NOISE HOOD FAN FOR 6KM-5102S N.A. 4

90 6EHKM-5102S Z SPACE HEATER FOR DEGASSING AIRCOMPRESSOR N.A. 4

30 6ABM-5103 M AIR BLOWER A C 62 2.60 4.20 8.12 0.40 4 0.83 0.9 5.06 2.45 3.13 1.52 X X X X D 3 X 6-SW-611 A SAFE 6PK-5130/31 8

90 6RFM-5103 M ROTARY FEEDER A C 25 0.60 0.75 2.10 0.40 4 0.71 0.73 1.06 0.99 0.85 0.79 X X X D 3 X 6-SW-613 A SAFE 6PK-5130/31 6

90 6ABM-5104A M WASTE AIR BLOWER A C 54 130.00 200.00 33.20 4.16 4 0.95 0.88 210.53 113.63 136.84 73.86 X X X D 2 X 6-SW-601 A SAFE 6PK-5130/31 4

90 6EHABM-5104A Z SPACE HEATER FOR WASTE AIR BLOWERMOTOR A D 0.25 1.09 0.23 X 1 1 0.25 0.00 0.25 0.00 E 3 6-SW-601 A SAFE 6PK-5130/31 4

90 6ABM-5104S M WASTE AIR BLOWER A R 54 130.00 200.00 33.20 4.16 4 0.95 0.88 210.53 113.63 136.84 73.86 X X X D 2 X 6-SW-601 B SAFE 6PK-5130/31 4

90 6EHABM-5104S Z SPACE HEATER FOR WASTE AIR BLOWERMOTOR A D 0.25 1.09 0.23 X 1 1 0.25 0.00 0.25 0.00 3 6-SW-601 B SAFE 6PK-5130/31 4

90 6M-5130 Q SAMPLER A D N.A. 6PK-5130/31 2

90 6KM- 9001A M TRANSPORT COMPRESSOR FROM DEGASSINGTO ELUTRIATOR A C 28 327.00 420.00 77.93 4.16 2 0.88 0.85 477.27 295.79 371.59 230.29 X X X D 3 X 6-SW-601 A 2 IIB T3 6PK-9003 4

90 6EHKM-9001A Z SPACE HEATER FOR TRANSPORT COMPRESSORMOTOR A D 0.50 2.17 0.23 X 1 1 0.50 0.00 0.50 0.00 E 3 6-SW-601 A 2 IIB T3 6PK-9003 4

90 6KBM-9001A1 M NOISE HOOD FAN FOR SCREW COMPRESSOR N.A. 4

90 6KBM-9001A2 M NOISE HOOD FAN FOR SCREW COMPRESSOR N.A. 4

90 6MKM-9001A M OIL DEMISTOR FOR 6K-9001A A C 83 0.30 0.55 1.53 0.40 0.7 0.74 0.79 0.71 0.43 0.39 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 8

90 6KM- 9001B M TRANSPORT COMPRESSOR FROM DEGASSINGTO ELUTRIATOR A C 28 327.00 420.00 69.00 4.16 2 0.96 0.88 437.50 236.14 340.63 183.85 X X X D 3 X 6-SW-601 B 2 IIB T3 6PK-9003 4

90 6EHKM-9001B Z SPACE HEATER FOR TRANSPORT COMPRESSORMOTOR A D 0.50 2.17 0.23 X 1 1 0.50 0.00 0.50 0.00 E 3 6-SW-601 B 2 IIB T3 6PK-9003 4

90 6KBM-9001B1 M NOISE HOOD FAN FOR SCREW COMPRESSOR A C N.A. 4

90 6KBM-9001B2 M NOISE HOOD FAN FOR SCREW COMPRESSOR A C N.A. 4

90 6MKM-9001B M OIL DEMISTOR FOR 6K-9001B A C 83 0.30 0.55 1.53 0.40 0.7 0.74 0.79 0.71 0.43 0.39 X X X D 3 X 6-SW-613 B 2 IIB T3 6PK-9003 8

LOG M RADIAL FAN (FOR ACCELERATION GAS) N.A. 5

LOG M RADIAL FAN (FOR ACCELERATION GAS) N.A. 3

LOG M RADIAL FAN N.A. 3

LOG M RADIAL FAN N.A. 3

90 6RFM-9001A M DEGASSING ROTARY FEEDER SILOS OUTLET A C 38 2.90 4.00 8.74 0.40 4 0.79 0.84 5.09 3.29 3.69 2.38 X X X X D 3 X 6-VFD-612-8 A 2 IIB T3 6PK-9003 VFD 6

12/14/2007 15 of 20

Page 61: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

90 6RFM-9001B M DEGASSING ROTARY FEEDER SILOS OUTLET A C 38 2.90 4.00 8.74 0.40 4 0.79 0.84 5.09 3.29 3.69 2.38 X X X X D 3 X 6-VFD-612-9 A 2 IIB T3 6PK-9003 VFD 6

LOG 6HO- 9001 Q LOGISTIC HOIST FOR BAGS ROLL(LDPE) N.A. 5

LOG 6ABM-9004A M ELUTRIATOR BLOWER A C 33 57.90 77.28 133.43 0.40 2 0.95 0.88 81.35 43.91 60.95 32.90 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 8

LOG 6ABM-9004B M ELUTRIATOR BLOWER A C 33 57.90 77.28 133.43 0.40 2 0.95 0.88 81.35 43.91 60.95 32.90 X X X D 3 X 6-SW-613 B 2 IIB T3 6PK-9003 8

LOG M BLOWER (STORAGE SILO) A R N.A. 4

90 6RFM-9002 M ROTARY FEEDER SILOS OUTLET A C 38 2.90 4.00 8.74 0.40 4 0.79 0.84 5.09 3.29 3.69 2.38 X X X x D 3 X 6-VFD-612-10 A 2 IIB T3 6PK-9003 VFD 6

LOG 6RFM-9004 M 6V-9004 OUTLET ROTARY FEEDER A C 30 2.30 3.00 6.32 0.40 4 0.83 0.83 3.64 2.44 2.79 1.87 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 6

LOG 6RFM-9005 M 6V-9004 OUTLET ROTARY FEEDER A C 34 0.56 0.75 2.10 0.40 4 0.71 0.73 1.06 0.99 0.79 0.74 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 6

LOG 6RFM-9006 M 6V-9005 OUTLET ROTARY FEEDER A C 30 2.30 3.00 6.32 0.40 4 0.83 0.83 3.64 2.44 2.79 1.87 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 6

LOG 6RFM-9007 M 6V-9005 OUTLET ROTARY FEEDER A C 34 0.56 0.75 2.10 0.40 4 0.71 0.73 1.06 0.99 0.79 0.74 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 6

LOG. 6KM- 9003A M TRANSPORT COMPRESSOR FROM DEGASSINGTO STORAGE SILOS A C 33 75.46 100.00 179.51 0.40 4 0.95 0.85 105.71 65.51 79.77 49.44 X X X D 3 X 6-SW-613 A 2 IIB T3 6PK-9003 4

LOG 6EHKM-9003A Z SPACE HEATER FOR TRANSPORT COMPRESSORMOTOR N.A. 4

LOG 6KBM-9003A1 M NOISE HOOD FAN FOR SCREW COMPRESSOR N.A. 4

LOG 6KBM-9003A2 M NOISE HOOD FAN FOR SCREW COMPRESSOR N.A. 4

LOG. 6KM- 9003B M TRANSPORT COMPRESSOR FROM DEGASSINGTO STORAGE SILOS A C 33 75.46 100.00 179.51 0.40 4 0.95 0.85 105.71 65.51 79.77 49.44 X X X D 3 X 6-SW-613 B 2 IIB T3 6PK-9003 4

LOG 6EHKM-9003B Z SPACE HEATER FOR TRANSPORT COMPRESSORMOTOR N.A. 4

LOG 6KBM-9003B1 M NOISE HOOD FAN FOR SCREW COMPRESSOR N.A. 4

LOG 6KBM-9003B2 M NOISE HOOD FAN FOR SCREW COMPRESSOR N.A. 4

LOG 5KM- 9005A M INSTRUMENT AIR COMPRESSOR A C 25 417.60 522.00 89.16 4.16 0.956 0.85 546.03 338.40 436.82 270.72 X X X X B 3 X 6-SW-601 A 2 IIB T3 5PK-9005 5

LOG 5EHKM-9005A Z SPACE HEATER FOR INSTRUMENT AIRCOMPRESSOR MOTOR A D 0.50 2.17 0.23 X 1.00 1.00 0.50 0.00 0.50 0.00 D 2 6-SW-601 A 2 IIB T3 5PK-9005 6

LOG 5KM- 9005S M INSTRUMENT AIR COMPRESSOR A R 25 417.60 522.00 89.16 4.16 0.956 0.85 546.03 338.40 436.82 270.72 X X X X B 3 X 6-SW-601 B 2 IIB T3 5PK-9005 5

LOG 5EHKM-9005S Z SPACE HEATER FOR INSTRUMENT AIRCOMPRESSOR MOTOR A D 0.50 2.17 0.23 X 1.00 1.00 0.50 0.00 0.50 0.00 D 2 6-SW-601 B 2 IIB T3 5PK-9005 6

402 56PM-9801A M OIL SEPARATOR PUMP TO OSBL A C 13 15.00 17.00 32.05 0.40 0.88 0.87 19.32 10.95 17.05 10.95 X X X D 3 X 6-SW-612 A 2 IIB T3 56-PK-980 7

402 56PM-9801S M OIL SEPARATOR PUMP TO OSBL A R 13 15.00 17.00 32.05 0.40 0.88 0.87 19.32 10.95 17.05 10.95 X X X D 3 X 6-SW-612 B 2 IIB T3 56-PK-980 7

SS 6-BC-651A Q 110 V DC SYSTEM A C 36.00 36.00 64.95 0.40 1 0.8 36.00 27.00 36.00 27.00 C 3 6-SW-614 A SAFE 4

SS 6-BC-651B Q 110 V DC SYSTEM A R 36.00 36.00 64.95 0.40 1 0.8 36.00 27.00 36.00 27.00 C 3 6-SW-614 A SAFE 4

SS 6-CP-602 Q AUXILIARY POWER SUPPLY A C 10.00 10.00 17.82 0.40 0.9 0.9 11.11 5.38 11.11 5.38 D 3 6-SW-611 A SAFE 6PK-1701 7

SS 6-CP-614 Q AUXILIARY POWER SUPPLY FOR DG CONTROLPANEL A C 15.00 15.00 26.73 0.40 0.9 0.9 16.67 8.07 16.67 8.07 D 3 6-SW-613 A SAFE 7

SS 6-DB-611A Q LIGHTING PANEL -SUBSTATION A C 39.00 39.00 69.50 0.40 0.9 0.9 43.33 20.99 43.33 20.99 D 3 6-SW-613 A SAFE 7

SS 6-DB-611B Q LIGHTING PANEL -SUBSTATION A R 39.00 39.00 69.50 0.40 0.9 0.9 43.33 20.99 43.33 20.99 D 3 6-SW-613 B SAFE 7

SS 6-DB-612A Q LIGHTING PANEL - PROCESS AREAS A C 39.00 39.00 69.50 0.40 0.9 0.9 43.33 20.99 43.33 20.99 D 3 6-SW-612 A SAFE 7

SS 6-DB-612B Q LIGHTING PANEL - PROCESS AREAS A R 39.00 39.00 69.50 0.40 0.9 0.9 43.33 20.99 43.33 20.99 D 3 6-SW-612 B SAFE 7

SS 6-DB-613A Q LIGHTING PANEL - EXTRUSION AREA A C 66.00 66.00 117.61 0.40 0.9 0.9 73.33 35.52 73.33 35.52 D 3 6-SW-611 A SAFE 7

SS 6-DB-613B Q LIGHTING PANEL - EXTRUSION AREA A R 66.00 66.00 117.61 0.40 0.9 0.9 73.33 35.52 73.33 35.52 D 3 6-SW-611 B SAFE 7

SS 6-DB-614A Q LIGHTING PANEL - ROAD & AREA LIGHTING A C 42.00 42.00 74.84 0.40 0.9 0.9 46.67 22.60 46.67 22.60 D 3 6-SW-613 A SAFE 7

SS 6-DB-614B Q LIGHTING PANEL - ROAD & AREA LIGHTING A R 42.00 42.00 74.84 0.40 0.9 0.9 46.67 22.60 46.67 22.60 D 3 6-SW-613 B SAFE 7

SS 6-DB-621A Q EMERG. LIGHTING PANEL-SUBSTATION A C 48.00 48.00 85.54 0.40 0.9 0.9 53.33 25.83 53.33 25.83 D 3 6-SW-613 A SAFE 7

SS 6-DB-621B Q EMERG. LIGHTING PANEL-SUBSTATION A R 48.00 48.00 85.54 0.40 0.9 0.9 53.33 25.83 53.33 25.83 C 3 6-SW-614 A SAFE 7

SS 6-DB-622A Q EMERG. LIGHTING PANEL-PROCESS AREA A C 51.00 51.00 90.88 0.40 0.9 0.9 56.67 27.44 56.67 27.44 D 3 6-SW-613 A SAFE 7

SS 6-DB-622B Q EMERG. LIGHTING PANEL-PROCESS AREA A R 51.00 51.00 90.88 0.40 0.9 0.9 56.67 27.44 56.67 27.44 C 3 6-SW-614 A SAFE 7

12/14/2007 16 of 20

Page 62: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

SS 6-DB-631 Q SOCKET AND SPACE HEATER PANEL A C 55.00 55.00 98.01 0.40 0.9 0.9 61.11 29.60 61.11 29.60 D 3 6-SW-613 B SAFE 4

SS 6-DB-641 Q CATHODIC PROTECTION SYSTEM A C 2.00 2.00 6.20 0.23 X 0.9 0.9 2.22 1.08 2.22 1.08 D 3 6-SW-613 B SAFE 4

SS 6-DB-645 Q ELECTRICAL HEAT TRACING PANEL A C 50.00 50.00 89.10 0.40 0.9 0.9 55.56 26.91 55.56 26.91 C 2 6-SW-614 A SAFE 7

SS 6-ECP-604 Q EXCITATION PANEL FOR 6KM-1201 A C 78.30 87.00 155.03 0.40 0.9 0.9 96.67 46.82 87.00 42.14 D 3 6-SW-612 B SAFE 6PK1201 6

SS 6-ECP-603 Q EXCITATION PANEL FOR 6KM-1202 A C 225.00 250.00 445.50 0.40 0.9 0.9 277.78 134.53 250.00 121.08 D 3 6-SW-612 B SAFE 6PK1202 6

302 56-HVAC-611 Q HVAC PEROXIDE STORAGE N.A. 4

SS 6-HVAC-611 Q HVAC FOR LDPE SUBSTATION A C 94.00 103.00 183.55 0.40 0.9 0.9 114.44 55.43 104.44 50.58 D 3 6-SW-613 B SAFE 8

SS 6-HVAC-612 Q HVAC - INSTRUMENT RACK ROOM A C 59.00 72.00 128.30 0.40 0.9 0.9 80.00 38.75 65.56 31.75 C 3 6-SW-614 A SAFE 6

10 6-HVAC-613-1 Q HVAC ANALYSER HOUSE AS-L01 A C 6.00 10.00 17.82 0.40 0.9 0.9 11.11 5.38 6.67 3.23 C 3 6-SW-614 A 2 IIB T3 7

10 6-HVAC-613-2 Q HVAC ANALYSER HOUSE AS-L01 A R 6.00 10.00 17.82 0.40 0.9 0.9 11.11 5.38 6.67 3.23 C 3 6-SW-614 A 2 IIB T3 7

30 6-HVAC-614 Q HVAC EXTRUSION BUILDING N.A. 4

303 6-HVAC-615 Q HVAC OPERATOR SHELTER (LDPE) A C 43.00 65.00 115.83 0.40 0.9 0.9 72.22 34.98 47.78 23.14 D 3 6-SW-613 B SAFE 7

401 6-HVAC-616 Q HVAC IN A ROOM IN CHEMICAL STORAGE(WAREHOUSE) SHIFTED TO HDPE 6

220 6-HVAC-617 Q HVAC FOR LAB EXTRUDER A C 10.00 10.00 17.82 0.40 0.9 0.9 11.11 5.38 11.11 5.38 C 3 6-SW-614 A SAFE 6PK-5101 ( 20ASUPPLY REQUIRED) 6

401 56-HVAC-619 Q HVAC IN A ROOM IN CHEMICAL STORAGE(WAREHOUSE) A C 43.65 64.70 115.30 0.40 0.9 0.9 71.89 34.82 48.50 23.49 D 2 6-SW-613 B SAFE

TAG CHANGED,RATING HOLD,

FEEDING SHIFTEDFROM 5 SW 614 TO 6

7

SS 6-HVAC-618 Q HVAC MAIN SUBSTATION (CHILLERS) SHIFTED TO HDPE 7

60 6-LP-1000-01 Q PEROXIDE DOSING PUMP POWER SUPPLYDISTRIBUTION PANEL DELETED 7

60 6-LP-1000-01-1 Q PEROXIDE DOSING PUMP POWER SUPPLYDISTRIBUTION PANEL INCOMER-1 A C 8.00 8.00 14.26 0.40 0.9 0.9 8.89 4.31 8.89 4.31 D 3 6-SW-611 A SAFE 7

60 6-LP-1000-01-2 Q PEROXIDE DOSING PUMP POWER SUPPLYDISTRIBUTION PANEL INCOMER-2 A C 20.00 20.00 35.64 0.40 0.9 0.9 22.22 10.76 22.22 10.76 D 3 6-SW-611 A SAFE 7

220 6-PK5101 Q SOCKET FEEDER FOR LAB EXTRUDER A C 20.00 25.00 56.38 0.40 0.8 0.8 31.25 23.44 25.00 18.75 D 3 6-SW-613 A SAFE 6PK-5101(63ASUPPLY REQUIRED) 6

SS 6-SW-600B Q PANEL HEATER A D 1.05 1.52 0.40 1 1 1.05 0.00 1.05 0.00 E 2 6-DB-631 A SAFE 7

SS 6-SW-614A Q EMERGENCY DISTRIBUTION BOARD A C 710.00 1023.00 1822.98 0.40 0.9 0.9 1136.67 550.51 788.89 382.08 D 3 6-SW-611 B SAFE 7

SS 6-SW-614B Q EMERGENCY DISTRIBUTION BOARD A R 940.00 1023.00 1822.98 0.40 0.9 0.9 1136.67 550.51 1044.44 505.85 C 3 6-DEG-614 SAFE 5

LOG 56-SW-613B Q EMERGENCY DISTRIBUTION BOARD INLOGISTICS SS A R 100.00 100.00 178.20 0.40 0.9 0.9 111.11 53.81 111.11 53.81 C 2 6-SW-614 A SAFE 7

SS 6-TR-600A-1 Q LDPE POWER TRANSFORMER COOLING FANSUPPLY A C 6.00 7.50 13.36 0.40 0.90 0.90 8.33 4.04 6.67 3.23 C 3 6-SW-614 A SAFE 6

SS 6-TR-600A-2 Q LDPE POWER TRANSFORMER OLTC SUPPLY A R 0.90 1.50 2.67 0.40 0.90 0.90 1.67 0.81 1.00 0.48 C 3 6-SW-614 A SAFE 6

SS 6-TR-601A Q LDPE POWER TRANSFORMER A C 6300.00 295.83 13.80 0.99 0.90 6363.64 3082.05 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-601B Q LDPE POWER TRANSFORMER A R 6300.00 295.83 13.80 0.99 0.90 6363.64 3082.05 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-602 Q TRANSFORMER FOR 6-VFD-602 A C 3500.00 5200.00 236.09 13.80 0.97 0.95 5360.82 1762.02 3608.25 1185.97 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-611A Q LDPE DISTRIBUTION TRANSFORMER A C 2500.00 117.39 13.80 0.99 0.90 2525.25 1223.04 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-611B Q LDPE DISTRIBUTION TRANSFORMER A R 2500.00 117.39 13.80 0.99 0.90 2525.25 1223.04 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-612A Q LDPE DISTRIBUTION TRANSFORMER A C 2500.00 117.39 13.80 0.99 0.90 2525.25 1223.04 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-612B Q LDPE DISTRIBUTION TRANSFORMER A R 2500.00 117.39 13.80 0.99 0.90 2525.25 1223.04 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-613A Q LDPE DISTRIBUTION TRANSFORMER A C 2500.00 117.39 13.80 0.99 0.90 2525.25 1223.04 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-613B Q LDPE DISTRIBUTION TRANSFORMER A R 2500.00 117.39 13.80 0.99 0.90 2525.25 1223.04 0.00 0.00 D 3 6-SW-600A A SAFE COLUMN 8 KVA RATING 5

SS 6-TR-614 Q TRANSFORMER FOR 6-VFD-614 A C 280.00 630.00 91.98 4.16 0.97 0.98 649.48 131.88 288.66 58.61 D 3 6-SW-601 B SAFE COLUMN 8 KVA RATING 5

LOG 56-TR-614A Q LOGISTICS SUBSTATION A C 1412.00 2000.00 98.91 13.80 0.94 0.9 2127.66 1030.47 1502.13 727.51 D 3 6-SW-600A A SAFE 5

LOG 56-TR-614B Q LOGISTICS SUBSTATION A R 1412.00 2000.00 98.91 13.80 0.94 0.9 2127.66 1030.47 1502.13 727.51 D 3 6-SW-600A A SAFE 5

SS 6-UP-611A Q UPS FOR INSTRUMENT(INCOMER A) A C 147.00 147.00 265.23 0.40 1 0.8 147.00 110.25 147.00 110.25 C 3 6-SW-614 A SAFE 5

12/14/2007 17 of 20

Page 63: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

SS 6-UP-611 B Q UPS FOR INSTRUMENT(INCOMER B) A R 147.00 147.00 265.23 0.40 1 0.8 147.00 110.25 147.00 110.25 C 3 6-SW-614 A SAFE 5

SS 6-UP-611 C Q UPS FOR INSTRUMENT(BYPASS) A R 147.00 147.00 265.23 0.40 1 0.8 147.00 110.25 147.00 110.25 C 3 6-SW-614 A SAFE 5

SS 6-UP-612A Q UPS SYSTEM (TELECOM) N.A. 3

SS 5-UP-612B Q UPS FOR TELECOM(INCOMER B) A R 76.00 76.00 137.12 0.40 1 0.8 76.00 57.00 76.00 57.00 C 3 6-SW-614 A SAFE 5

SS 5-UP-612C Q UPS FOR TELECOM(BYPASS) A R 76.00 76.00 137.12 0.40 1 0.8 76.00 57.00 76.00 57.00 C 3 6-SW-614 A SAFE 5

SS 6-UP-621A Q UPS SYSTEM (SAFETY LIGHTING) N.A. 3

SS 6-UP-621 B Q UPS SYSTEM (SAFETY LIGHTING) N.A. 3

SS 6-SS-603 Q SOFT STARTER POWER FANS A C 15.00 15.00 27.00 0.40 0.8 0.8 18.75 14.06 18.75 14.06 D 3 6-SW-612 B SAFE6PK-1202/SOFTSTARTER BYPACKAGE VENDOR

7

SS 6-SS-603 Q DEMAGNETISATION CUBICLE A C 15.00 15.00 37.00 0.40 1 1 15.00 0.00 15.00 0.00 D 3 6-SW-612 B SAFE 6PK-1202 7

Z HEATER 6

SS 6-VFD-602 Q VFD FOR MAIN EXTRUDER A C 3500.00 4400.00 1598.68 1.725 0.94 0.98 4680.85 950.49 3723.40 756.07 D 3 6-TR-602 A SAFE 6PK-1701/VFD BYPACKAGE VENDOR 5

SS 6-VFD-602 Q VFD FOR MAIN EXTRUDER AUXILIARY SUPPLY A C 30.00 30.00 53.46 0.40 0.9 0.9 33.33 16.14 33.33 16.14 D 3 6-SW-611 A SAFE 6PK-1701, NEWADDITION 8

SS 6-VFD-614 Q VFD FOR GRANULATOR A C 280.00 400.00 683.44 0.40 0.96 0.88 416.67 224.89 291.67 157.42 D 3 X 6-TR-614 B SAFE 6PK-1701/VFD BYPACKAGE VENDOR 5

12/14/2007 18 of 20

Page 64: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

HDPE 400 KT/YLDPE 400 KT/Y

Uni

tUser Item

Use

r Typ

e Description

Inst

alla

tion

Ope

ratio

n

Des

ign

mar

gin

for

mot

or

Mac

hine

Abs

orbe

d P o

wer

(kW

)

Mot

or R

ated

Pow

er

(kW

)

Mot

or R

ated

C

urre

nt (A

)

S tat

ic L

oad

Rat

ed

Pow

er (k

W)

Stat

ic L

oad

Rat

ed

Cur

rent

(A)

Rat

ed V

olta

ge (

kV)

S ing

le P

hase

Loa

d

Num

ber o

f Pol

es

E ffic

ienc

y

@

Ope

ratin

g

Pow

er F

acto

r

@

Ope

ratin

g

Rat

ed A

ctiv

e Lo

ad

(kW

)

Rat

ed R

eact

ive

Load

(kVA

R)

Con

sum

ed A

ctiv

e Lo

ad (k

W)

Con

sum

ed

Rea

ctiv

e Lo

ad

( kVA

R)

Run

/Rev

ersa

lC

ontr

ol fr

om

P roc

ess

Boa

rdIn

terlo

ck fr

om

P roc

ess

Boa

rdSi

gnal

Lig

ht o

n P r

oces

s B

oard

ESD

Shu

t Dow

nA

uto-

Star

ting

of

Stan

dby

Mot

orC

ontin

ous

Dut

y R

equi

red

P ack

age

Pow

er

Boa

rdD

ata

Acc

urac

y

Loca

l Am

met

er

F ed

From

Bus

-sec

tion

Inst

alle

d in

Zon

e

Not

es

Rev

isio

n

1 2 3 4 5 6 7A 7B 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

Client Ref.: TASNEE Issue 08Sheet SeeFooter

Tasnee Identification Code

Plant:

3276-NN-LN-002001

AA-BBBBBB-CC-DD-EEEFF

Tecnimont Identification CodeELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

AL JUBAIL - KSALocation:

SS 6-VFD-611 M VFD FOR 6PK-1701 N.A. 3

SS 6-VFD-611-1 Q VFD FOR DOSING PUMP 6PM-1701A A C 1.00 5.50 8.71 0.40 0.98 0.93 5.61 2.22 1.02 0.40 D 3 6-SW-611 A SAFE 6PK-1701/VFD BYPACKAGE VENDOR 6

SS 6-VFD-611-2 Q VFD FOR DOSING PUMP 6PM-1701B A C 1.00 5.50 8.71 0.40 0.98 0.93 5.61 2.22 1.02 0.40 D 3 6-SW-611 B SAFE 6PK-1701/VFD BYPACKAGE VENDOR 6

SS 6-VFD-611-3 Q VFD FOR SATELLITE EXTRUDER(MASTERBATCH) 6EXM-1702 A C 110.00 260.00 411.77 0.40 0.98 0.93 265.31 104.86 112.24 44.36 D 2 6-SW-611 A SAFE 6PK-1701/VFD BY

PACKAGE VENDOR 6

SS 6-VFD-611-4 Q VFD FOR LOSS IN WEIGHT FEEDER 6WM-1710 A C 0.30 1.00 1.58 0.40 0.98 0.93 1.02 0.40 0.31 0.12 D 2 6-SW-611 B SAFE 6PK-1701/VFD BYPACKAGE VENDOR 6

SS 6-VFD-611-5 Q VFD FOR PH BUFFERING DOSING PUMP 6PM-1910 7

SS 6-VFD-612 Q VFD FOR DOSING PUMPS AND STEAMCONDENSOR FANS N.A. 3

SS 6-VFD-612-1 Q VFD FOR MODIFIER (PA) DOSING PUMP 6PM-1210A A C 5.00 7.50 11.88 0.40 0.98 0.93 7.65 3.02 5.10 2.02 D 3 6-SW-612 A SAFE 5

SS 6-VFD-612-2 Q VFD FOR MODIFIER (PA) DOSING PUMP 6PM-1210S A R 5.00 7.50 11.88 0.40 0.98 0.93 7.65 3.02 5.10 2.02 D 3 6-SW-612 B SAFE 5

SS 6-VFD-612-3 Q VFD FOR LP STEAM CONDENSER FAN 6EM-1803C A C 30.00 55.00 87.11 0.40 0.98 0.93 56.12 22.18 30.61 12.10 D 3 6-SW-612 A SAFE 5

SS 6-VFD-612-4 Q VFD FOR LP STEAM CONDENSER FAN 6EM-1803D A C 30.00 55.00 87.11 0.40 0.98 0.93 56.12 22.18 30.61 12.10 D 3 6-SW-612 A SAFE 5

SS 6-VFD-612-5 Q VFD FOR LP STEAM CONDENSER FAN 6EM-1803E A C 30.00 55.00 87.11 0.40 0.98 0.93 56.12 22.18 30.61 12.10 D 3 6-SW-612 A SAFE 5

SS 6-VFD-612-6 Q VFD FOR LP STEAM CONDENSER FAN 6EM-1803F A C 30.00 55.00 87.11 0.40 0.98 0.93 56.12 22.18 30.61 12.10 D 3 6-SW-612 B SAFE 5

SS 6-VFD-612-7 Q VFD FOR MP STEAM CONDENSER FAN 6EM-1804B A C 30.00 55.00 87.11 0.40 0.98 0.93 56.12 22.18 30.61 12.10 D 3 6-SW-612 B SAFE 5

SS 6-VFD-612-8 Q VFD FOR DEGASSING SILO OUTLET ROTARYFEEDER - 6RFM-9001A A C 3.50 5.50 8.71 0.40 0.98 0.93 5.61 2.22 3.57 1.41 D 3 6-SW-613 A SAFE 5

SS 6-VFD-612-9 Q VFD FOR DEGASSING SILO OUTLET ROTARYFEEDER - 6RFM-9001B A C 3.50 5.50 8.71 0.40 0.98 0.93 5.61 2.22 3.57 1.41 D 3 6-SW-613 B SAFE 5

SS 6-VFD-612-10 Q VFD FOR OFF SPEC SILO OUTLET ROTARYFEEDER - 6RFM-9002 A C 3.50 5.50 8.71 0.40 0.98 0.93 5.61 2.22 3.57 1.41 D 3 6-SW-613 B SAFE 5

SS 6-VFD-613-1 Q VFD FOR WASTE GAS FAN 6ABM-4201 A C 150.00 260.00 411.77 0.40 0.98 0.93 265.31 104.86 153.06 60.49 D 3 6-SW-613 A SAFE 6PK-4201, BY PACKAGEVENDOR 6

SS 6-VFD-613-2 Q VFD FOR COMBUSTION AIR FAN 6ABM-4202 A C 18.00 25.00 39.59 0.40 0.98 0.93 25.51 10.08 18.37 7.26 D 3 6-SW-613 B SAFE 6PK-4201, BY PACKAGEVENDOR 6

SS 6-VFD-613-3 Q VFD FOR HDPE WASTE GAS FAN A C 7.00 11.00 17.42 0.40 0.98 0.93 11.22 4.44 7.14 2.82 D 3 6-SW-613 B SAFE 6PK-4201, BY PACKAGEVENDOR 6

20 6-WP-611 Q WELDING RECEPTACLE POLYMER AREA A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-612 A 1 IIB T3 7

20 6-WP-612 Q WELDING RECEPTACLE POLYMER AREA N.A.

10 6-WP-613 Q WELDING RECEPTACLE COMPRESSION A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-612 A 2 IIB T3 7

10 6-WP-614 Q WELDING RECEPTACLE COMPRESSION A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-612 B 2 IIB T3 7

30 6-WP-615 Q WELDING RECEPTACLE EXTRUSION A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-611 A 2 IIB T3 7

90 6-WP-616 Q WELDING RECEPTACLE DEGASSING A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-613 A SAFE 6

50 6-WP-617 Q WELDING RECEPTACLE HOT WATER HANDLING A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-612 A SAFE 6

SS 6-WP-618 Q WELDING RECEPTACLE FOR SUBSTATION A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-613 A SAFE 6

302 6-WP-619 Q WELDING RECEPTACLE FOR PEROXIDESTORAGE AREA A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-614 A SAFE 6

303 6-WP-620 Q WELDING RECEPTACLE FOR CHEMICALSTORAGE AREA A R 45.00 45.00 101.49 0.40 0.80 0.80 56.25 42.19 56.25 42.19 3 6-SW-613 A SAFE 6

SS 56-DB-621B Q EMERGENCY DISTRIBUTION BOARD INLOGISTICS SS A R N.A. 2

10 6ZM- 11- 001 Q FIRE FIGHTING MONITORS A D 1.00 1.00 6.79 0.23 X 0.80 0.80 1.25 0.94 1.25 0.94 C 3 6-SW-614 A 2 IIB T3 7

10 6ZM- 11- 002 Q FIRE FIGHTING MONITORS A D 1.00 1.00 6.79 0.23 X 0.80 0.80 1.25 0.94 1.25 0.94 C 3 6-SW-614 A 2 IIB T3 7

10 6ZM- 11- 003 Q FIRE FIGHTING MONITORS A D 1.00 1.00 6.79 0.23 X 0.80 0.80 1.25 0.94 1.25 0.94 C 3 6-SW-614 A 2 IIB T3 7

SS HOLD Q FIRE & GAS SYSTEM PANEL N.A. 3

SS HOLD Q TELECOM SYSTEM PANEL N.A. 3

CR 6-PDC-611 Q INSTRUMENT NORMAL POWER SUPPLYAUXILIARY PANEL A D 2.00 2.00 4.51 0.40 0.80 0.80 2.50 1.88 2.50 1.88 D 3 6-SW-613 B SAFE 8

SS 6-PDC-612 Q INSTRUMENT NORMAL POWER SUPPLYAUXILIARY PANEL A C 30.00 30.00 67.66 0.40 0.80 0.80 37.50 28.13 37.50 28.13 D 3 6-SW-613 B SAFE 8

12/14/2007 19 of 20

Page 65: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

.

ELECTRICAL USER LIST AND LOAD SUMMARY- LDPE

LOAD SUMMARY

648.6 820.0 56.3 369.1 336.1 397.1 42.2 202.5 730.5 911.1 70.3 421.0 0.89 0.90 1641.41

815.3 533.4 176.6 547.6 451.5 263.8 131.1 317.5 932.0 595.1 220.0 633.0 0.87 0.90 1526.71

940.1 624.2 168.8 233.3 511.4 338.7 126.6 129.3 1070.2 710.2 210.9 266.7 0.88 0.88 1780.35

529.4 0.0 967.3 0.0 325.0 0.0 629.0 0.0 621.2 0.0 1153.8 0.0 0.85 621.21

2404.0 1977.6 401.6 1150.0 1299.0 999.5 299.9 649.3 2732.5 2215.9 501.2 1320.7 0.88 0.89

4947.93

1467.0 629.3 0.0 1095.4 883.8 242.5 0.0 653.5 1712.7 674.4 0.0 1275.5 0.86 0.93 2379.69

32424.6 0.0 0.0 0.0 3435.2 0.0 0.0 0.0 32606.1 0.0 0.0 0.0 0.99 32606.08

7446.5 0.0 3838.3 0.0 3110.3 0.0 1924.3 0.0 8070.0 0.0 4293.6 0.0 0.92

8069.97

0.98 47409.31

7446.5 3110.3 8070.0

1126.2 2379.7

4381.6 1551.6

Tasnee Identification Code

AA-BBBBBB-CC-DD-EEEFF

3276-NN-LN-002001

Sheet Seefooter Issue 08

Tecnimont Identification Code

Plant: HDPE/LDPE 400 KT/Y Client Ref.: TASNEE Location: AL JUBAIL - KSA

S PAR

EK V

A BU

S A

S PAR

EK V

AR B

US

A

SPAR

EKV

AR B

US

B

POW

ER F

ACTO

R

OPE

RAT

ING

BU

S B

TOTA

L R

UN

NIN

G-

kVA

6-SW-600A 13.8 KV(MOTOR +

EXTRUDER)EXCLUDING MV

FEEDERS TO SS#4SWITCHBOARDS

6-SW-601 4.16 KV

2096.3

6-SW-600B 10 KV

32424.6

6-SW-613 0.4 KV

Total L.V (LOAD OF 6-SW-614 ALREADY

INCLUDED IN 6-SW-611)

6-SW-611 0.4 KV

6-SW-612 0.4 KV

6-SW-614 0.4 KVEMERGENCY

SUPPLY

SWITCHGEARS

SPAR

EK V

A BU

S B

INPU

TKV

AR B

US

B

INPU

TKW

BU

S A

INPU

TKW

BU

S B

SPAR

EKW

BU

S A

SPAR

EKW

BU

S B

INPU

TKV

AR B

US

A

INPU

TKV

A BU

S A

INPU

TKV

A BU

S B

46349 9970Grand total L.V +M.V 47409.36485 3527 7382.3

949.2 1818.9

POW

ER F

ACTO

R

OPE

RAT

ING

BU

S A

1275.5

2298.5 4947.9

1095.4 653.5

3838.3 1924.3 4293.6

0.0 3435.2 0.0 32606.1 0.0

Sheet 20 of 20

Page 66: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

EIA TASNEE Annex 5 to Attachment 6 Data for noise model used for the calculation

Page 67: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Work area

from ... to ... Dimensions area

x /m 4000.00 14000.00 10000.00 100.00 km²

y /m -2000.00 8000.00 10000.00

z /m 0.00 100.00 100.00

Terrain height in the corners

xmin / ymax (z4) 0.00 xmax / ymax (z3) 0.00

xmin / ymin (z1) 0.00 xmax / ymin (z2) 0.00

Attribution of element groups to variants

Element group Variant 0 Variant 1

Group 0 + +

Group 1 +

Available grids

Name x min /m

x max /m

y min /m

y max /m

dx /m

dy /m

nx

ny

Referenc

Height/m

Range

Grid 0 4000.00 14000.00 0.00 10000.00 25.00 25.00 401 401 absolute 1.50 Rectangle

Grid 1 4000.00 14000.00 -2000.00 8000.00 25.00 25.00 401 401 relative 1.50 Rectangle

Grid 2 7272.00 7458.00 5832.00 6180.00 2.00 2.00 94 175 relative 0.00 Rectangle

Calculation model

Adapt assessment area seamlessly to the receiver position

...for single points No

...for grid calculation No

Take selected elements into account no matter where receivers are located: No

Free field in front of refl. surfaces/m 1.00

House: white border in grid No

Frequency

Type of Spectrum Octave bands (linear)

First frequency band /Hz 16.00

Last frequency band /Hz 8000.00

Calculation of receiver "reference settings"

Caculation of grid "reference settings"

Optimised setting: Optimised setting:

Parameter "reference settings" Receiver calculation (OFF) Grid calculation (OFF)

Projection of line sound sources Yes Yes Yes

Projection of area sound sources Yes Yes Yes

Minimum length for sections /m 1.00 1.00 1.00

Add. factor for distance criterion 1.00 1.00 1.00

Limiting range of sound sources No No Yes

minimum level difference /dB No No 30.00

Cut-off limit for insertion loss Yes Yes Yes

Limit according to regulation Yes Yes Yes

Calculate attenuation forVDI 2720, ISO9613

lateral pathway Yes Yes No

lateral pathway for image sources No No No

Reflection (max. order) 1 1 No reflection

Image source from projection Yes No

No refl. if entirely screened Yes No

Limiting range of reflecting surfaces /m No 200.00

Save rays as help lines No No

Page 68: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Multiple reflections No No No

Angle increments (x-y)°

Angle increments (z)°

maximum reflection pathway length

as a multiple of the direct distance

Ray splitting on refl. area

Global parameters

Pre-setting of G outside of elements DBOD 0.50

temperature /° 25

relative humidity /% 70

Gross living area in m²/inhabitant 40.00

Average floor height in m 2.80

Simplified meteorology (Guideline Int. Comp. Methods): Day Evening Night

C0 /dB (local meteorological influence) 2.00 2.00 2.00

Parameters of library: ISO 9613

down-wind conditions No

Apply flat-rate C0 Yes

Simplified equation (Nr. 7.3.2) for ground effect

for frequency-dependent calculation No

for overall A-weighted calculation Yes

calculate distance attenuation only No

Attenuation due to screening - subtract negative ground effect Yes

Accounts for vegetation Yes

Accounts for housing Yes

Accounts for ground effect Yes

Available co-ordinate systems

Name P1.x /m

P1.y /m

P1.z /m

P2.x /m

P2.y /m

P2.z /m

P3.x /m

P3.y /m

P3.z /m

Global system 0.00 0.00 0.00 1.00 0.00 0.00 1.00 1.00 0.00

Plane XZ/front view 0.00 0.00 0.00 1.00 0.00 0.00 1.00 0.00 1.00

Plane YZ/from right 0.00 0.00 0.00 0.00 1.00 0.00 0.00 1.00 1.00

Symbol (7) Variant 0

SYMB001 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7353.14 6115.89 0.00

SYMB002 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7353.14 6116.87 0.00

SYMB003 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Page 69: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7354.12 6114.92 0.00

SYMB004 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7381.33 5845.74 0.00

SYMB005 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7380.36 6114.92 0.00

SYMB006 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7353.14 6117.84 0.00

SYMB007 Label HPKT Type Bitmap

Group Group 0 Length /m 20.00

Display SYMB Width /m 20.00

Number of nodes 1 Angle /° 0

Length/m --- Framed No

Area /m² --- Keep ratio No

Geometry Nr x/m y/m z (rel) /m

1 7353.14 5845.74 0.00

Reception point (3) Variant 0

IPkt001 Label IPkt Land-use ---

Group Group 0

Display IPkt

Number of nodes 1

Length/m ---

Area /m² ---

Geometry Nr x/m y/m z (rel) /m

1 10289.75 6042.40 1.50

IPkt002 Label RP2 Land-use ---

Group Group 0

Display IPkt

Number of nodes 1

Length/m ---

Area /m² ---

Geometry Nr x/m y/m z (rel) /m

1 7180.21 -1098.94 1.50

Page 70: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

IPkt003 Label RP1 Land-use ---

Group Group 0

Display IPkt

Number of nodes 1

Length/m ---

Area /m² ---

Geometry Nr x/m y/m z (rel) /m

1 10325.09 6021.20 1.50

Building (1) Variant 0

HAUS001 Label Cooling Tower /WÄNDE Constant abs. height /m No

Group Group 0 Reflection Yes

Display HAUS Reflecting side left

Number of nodes 5 Absorption loss /dB 0.00

Length/m 593.20 Number of inhabitants 0.00

Area /m² 6986.64

Geometry Nr x/m y/m z (abs) /m

1 7354.10 5845.10 12.00

2 7354.10 6115.90 12.00

3 7379.90 6115.90 12.00

4 7379.90 5845.10 12.00

5 7354.10 5845.10 12.00

Reflecting element (1) Variant 0

REFL001 Label Cooling Tower /DACH Diffraction none

Group Group 0 Reflection Yes

Display REFL Reflecting side negative side

Number of nodes 5 Absorption loss /dB 0.00

Length/m 594.00

Area /m² 7046.00

Geometry Nr Diffracting edge x/m y/m z (abs) /m

1 --- 7354.00 5845.00 12.00

2 --- 7354.00 6116.00 12.00

3 --- 7380.00 6116.00 12.00

4 --- 7380.00 5845.00 12.00

5 --- 7354.00 5845.00 12.00

Housing/Industry (1) Variant 0

DBeb001 Label industrial area Constant rel. height /m 20.00

Group Group 1 D in dB/100m 2.00

Display DBeb D in %/100m 10.00

Number of nodes 10 Industy quellennah

Length/m 25903.37

Area /m² 41511170.60

Geometry Nr x/m y/m z (rel) /m

1 4088.34 7999.00 20.00

2 9636.04 7999.00 20.00

3 9565.37 6254.42 20.00

4 10378.09 4399.29 20.00

5 10378.09 4363.96 20.00

6 10289.75 1000.00 20.00

7 4123.67 1000.00 20.00

8 4159.01 3515.90 20.00

9 4070.67 7999.00 20.00

10 4088.34 7999.00 20.00

Compass (1) Variant 0

NPfl001 Label NORDPFEIL Width /cm 2.40

Group Group 0 Height /cm 3.00

Display NPfl Angle /° -43

Page 71: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Number of nodes 1 Show Yes

Length/m --- Arrow type 3

Area /m² ---

Geometry Nr x/m y/m z (rel) /m

1 13134.28 7381.63 0.00

Point srce/ISO 9613 (8) Variant 0

EZQi001 Label Others Ethylene Lw (Continuous) /dB(A) 124.1

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 127.1 - - 119.0 119.3 119.5 119.8 118.3 118.0 115.1 105.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 127.1 - - 119.0 119.3 119.5 119.8 118.3 118.0 115.1 105.0

Geometry Nr x/m y/m z (rel) /m

1 7526.32 5969.86 4.00

EZQi014 Label 6k1202-M1 Hyper comp Lw (Continuous) /dB(A) 116.0

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 121.7 - - 113.6 116.6 115.6 113.6 110.6 107.6 103.6 99.6

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 121.7 - - 113.6 116.6 115.6 113.6 110.6 107.6 103.6 99.6

Geometry Nr x/m y/m z (rel) /m

1 7311.50 4955.15 0.00

EZQi015 Label 6 EX 1701 Lw (Continuous) /dB(A) 112.0

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 117.7 - - 109.6 112.6 111.6 109.6 106.6 103.6 99.6 95.6

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 117.7 - - 109.6 112.6 111.6 109.6 106.6 103.6 99.6 95.6

Geometry Nr x/m y/m z (rel) /m

1 7270.47 4991.99 0.00

EZQi017 Label other sources LDPE Lw (Continuous) /dB(A) 113.6

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 119.3 - - 111.2 114.2 113.2 111.2 108.2 105.2 101.2 97.2

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 119.3 - - 111.2 114.2 113.2 111.2 108.2 105.2 101.2 97.2

Page 72: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Geometry Nr x/m y/m z (rel) /m

1 7252.00 4940.12 0.00

EZQi018 Label 3K-3101 Lw (Continuous) /dB(A) 117.8

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 120.6 - - 117.0 106.1 107.1 110.0 112.0 113.0 110.0 98.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 120.6 - - 117.0 106.1 107.1 110.0 112.0 113.0 110.0 98.0

Geometry Nr x/m y/m z (rel) /m

1 7550.00 5940.00 9.00

EZQi019 Label 3K-5001 Lw (Continuous) /dB(A) 114.8

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 117.6 - - 114.0 103.0 104.0 107.0 109.0 110.0 107.0 95.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 117.6 - - 114.0 103.0 104.0 107.0 109.0 110.0 107.0 95.0

Geometry Nr x/m y/m z (rel) /m

1 7562.05 5845.50 9.00

EZQi020 Label 3K-4401 Lw (Continuous) /dB(A) 114.9

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 117.7 - - 114.1 103.1 104.1 107.1 109.1 110.1 107.1 95.1

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 117.7 - - 114.1 103.1 104.1 107.1 109.1 110.1 107.1 95.1

Geometry Nr x/m y/m z (rel) /m

1 7575.00 5853.00 9.00

EZQi021 Label HDPE plant Lw (Continuous) /dB(A) 113.0

Group Group 0 Emission is Sound power level (Lw)

Display EZQi D0 0.0

Number of nodes 1 high noise source No

Length/m ---

Area /m² ---

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 120.4 - - 116.0 115.0 113.0 109.0 107.0 105.0 103.0 101.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw /dB 120.4 - - 116.0 115.0 113.0 109.0 107.0 105.0 103.0 101.0

Geometry Nr x/m y/m z (rel) /m

1 7276.13 5089.69 0.00

Page 73: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Area source/ISO 9613 (11) Variant 0

FLQi001 Label Cooling Tower /WAND1 Lw (Continuous) /dB(A) 74.0

Group Group 0 Lw" (Continuous) /dB(A) 41.9

Display Openings (sources) Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 566.00 high noise source No

Area /m² 3252.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 80.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 44.9 34.9 34.9 34.9 34.9 34.9 34.9 34.9 34.9 34.9 34.9

Geometry Nr x/m y/m z (abs) /m

1 7354.00 5845.00 0.00

2 7354.00 6116.00 0.00

3 7354.00 6116.00 12.00

4 7354.00 5845.00 12.00

5 7354.00 5845.00 0.00

FLQi002 Label Cooling Tower /WAND2 Lw (Continuous) /dB(A) 12.0

Group Group 0 Lw" (Continuous) /dB(A) -12.9

Display FLQi Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 76.00 high noise source No

Area /m² 312.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB(A) 12.0

Insulation /dB(A) -

Penalty /dB(A) -

Lw" /dB(A) -12.9

Geometry Nr x/m y/m z (abs) /m

1 7354.00 6116.00 0.00

2 7380.00 6116.00 0.00

3 7380.00 6116.00 12.00

4 7354.00 6116.00 12.00

5 7354.00 6116.00 0.00

FLQi003 Label Cooling Tower /WAND3 Lw (Continuous) /dB(A) 62.1

Group Group 0 Lw" (Continuous) /dB(A) 30.0

Display Openings (sources) Emission is SPL per unit area (Lw/m²)

Number of nodes 5 D0 0.0

Length/m 566.00 high noise source No

Area /m² 3252.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB(A) 30.0

Insulation /dB(A) -

Penalty /dB(A) -

Lw" /dB(A) 30.0

Geometry Nr x/m y/m z (abs) /m

1 7380.00 6116.00 0.00

2 7380.00 5845.00 0.00

3 7380.00 5845.00 12.00

4 7380.00 6116.00 12.00

5 7380.00 6116.00 0.00

FLQi004 Label Cooling Tower /WAND4 Lw (Continuous) /dB(A) 54.9

Group Group 0 Lw" (Continuous) /dB(A) 30.0

Display FLQi Emission is SPL per unit area (Lw/m²)

Number of nodes 5 D0 0.0

Length/m 76.00 high noise source No

Page 74: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Area /m² 312.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB(A) 30.0

Insulation /dB(A) -

Penalty /dB(A) -

Lw" /dB(A) 30.0

Geometry Nr x/m y/m z (abs) /m

1 7380.00 5845.00 0.00

2 7354.00 5845.00 0.00

3 7354.00 5845.00 12.00

4 7380.00 5845.00 12.00

5 7380.00 5845.00 0.00

FLQi005 Label Cooling Tower /DACH Lw (Continuous) /dB(A) 125.3

Group Group 0 Lw" (Continuous) /dB(A) 86.9

Display FLQi Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 594.00 high noise source No

Area /m² 7046.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 136.0 - - 133.0 130.9 126.0 123.0 120.5 113.7 109.0 106.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 97.5 - - 94.5 92.4 87.5 84.5 82.0 75.2 70.5 67.5

Geometry Nr x/m y/m z (abs) /m

1 7354.00 5845.00 12.00

2 7354.00 6116.00 12.00

3 7380.00 6116.00 12.00

4 7380.00 5845.00 12.00

5 7354.00 5845.00 12.00

FLQi008 Label 3pk-3103 Lw (Continuous) /dB(A) 118.0

Group Group 0 Lw" (Continuous) /dB(A) 84.2

Display FLQi Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 220.00 high noise source No

Area /m² 2400.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 127.9 - - 123.9 122.9 120.9 114.9 110.9 108.9 103.9 97.9

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 94.1 - - 90.1 89.1 87.1 81.1 77.1 75.1 70.1 64.1

Geometry Nr x/m y/m z (rel) /m

1 7620.69 5930.00 20.00

2 7620.69 5900.00 20.00

3 7540.69 5900.00 20.00

4 7540.69 5930.00 20.00

5 7620.69 5930.00 20.00

FLQi011 Label 3pk-4403 Lw (Continuous) /dB(A) 118.0

Group Group 0 Lw" (Continuous) /dB(A) 88.8

Display FLQi Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 118.00 high noise source No

Area /m² 840.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 127.9 - - 123.9 122.9 120.9 114.9 110.9 108.9 103.9 97.9

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 98.7 - - 94.7 93.7 91.7 85.7 81.7 79.7 74.7 68.7

Page 75: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

Geometry Nr x/m y/m z (rel) /m

1 7620.00 5840.00 20.00

2 7620.00 5816.00 20.00

3 7585.00 5816.00 20.00

4 7585.00 5840.00 20.00

5 7620.00 5840.00 20.00

FLQi012 Label 3pk-5003 Lw (Continuous) /dB(A) 115.0

Group Group 0 Lw" (Continuous) /dB(A) 81.8

Display FLQi Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 224.00 high noise source No

Area /m² 2112.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 125.0 - - 121.0 120.0 117.9 111.9 107.9 105.9 100.9 95.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 91.7 - - 87.8 86.8 84.7 78.7 74.7 72.7 67.7 61.8

Geometry Nr x/m y/m z (rel) /m

1 7580.00 5840.00 20.00

2 7580.00 5816.00 20.00

3 7492.00 5816.00 20.00

4 7492.00 5840.00 20.00

5 7580.00 5840.00 20.00

FLQi013 Label EA-2812 Lw (Continuous) /dB(A) 116.0

Group Group 0 Lw" (Continuous) /dB(A) 82.8

Display FLQi Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 224.00 high noise source No

Area /m² 2112.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 125.0 - - 121.0 120.0 117.9 111.9 107.9 105.9 100.9 95.0

Insulation /dB - - - - - - - - - -

Penalty /dB 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0

Lw" /dB 92.7 - - 88.8 87.8 85.7 79.7 75.7 73.7 68.7 62.8

Geometry Nr x/m y/m z (rel) /m

1 7595.18 6062.95 20.00

2 7595.18 6038.95 20.00

3 7507.18 6038.95 20.00

4 7507.18 6062.95 20.00

5 7595.18 6062.95 20.00

FLQi014 Label Opening 1 Lw (Continuous) /dB(A) 115.7

Group Group 0 Lw" (Continuous) /dB(A) 83.6

Display Openings (sources) Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 552.00 high noise source No

Area /m² 1620.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 126.5 - - 124.0 121.0 114.6 112.4 109.6 106.0 105.0 106.0

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 94.4 - - 91.9 88.9 82.5 80.3 77.5 73.9 72.9 73.9

Geometry Nr x/m y/m z (abs) /m

1 7354.00 6116.00 0.00

2 7354.00 5846.00 0.00

3 7354.00 5846.00 6.00

4 7354.00 6116.00 6.00

5 7354.00 6116.00 0.00

Page 76: Environmental Impact Assessment for TASNEE Petrochemicals ... · Calculation Model This document contains proprietary information belonging to Fluor B.V., its parent and/or affiliated

FLQi015 Label Opening 2 Lw (Continuous) /dB(A) 115.8

Group Group 0 Lw" (Continuous) /dB(A) 83.7

Display Openings (sources) Emission is Sound power level (Lw)

Number of nodes 5 D0 0.0

Length/m 552.00 high noise source No

Area /m² 1620.00

Emiss. variant Sum 16 Hz 31.5 Hz 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz

Continuous Emission /dB 126.5 - - 124.0 121.1 114.6 112.4 109.6 105.9 105.0 106.3

Insulation /dB - - - - - - - - - -

Penalty /dB - - - - - - - - - -

Lw" /dB 94.4 - - 91.9 89.0 82.5 80.3 77.5 73.8 72.9 74.2

Geometry Nr x/m y/m z (abs) /m

1 7380.00 5845.00 0.00

2 7380.00 6115.00 0.00

3 7380.00 6115.00 6.00

4 7380.00 5845.00 6.00

5 7380.00 5845.00 0.00

Gradients and gradient correction DStg for roads

Element Name Section s /m ds /m Gradient /% Gradient /% Gradient /% Gradient /%

m m co-ord. for calc. Continuous

*1): The gradient for the calculation has been entered directly.