12
ARCHITECT AND FACILITY MANAGEMENT GUIDE Entrance Systems for Health Care

Entrance Systems for Health Care

Embed Size (px)

DESCRIPTION

A variety of entrance systems available for the Health Care industry.

Citation preview

Page 1: Entrance Systems for Health Care

A R C H I T E C T A N D FAC I L I T Y M A NAG E M E N T G U I D E

Entrance Systemsfor Health Care

Page 2: Entrance Systems for Health Care

Horton Entrance Systemsfor Health Care

The automatic choice for performance,convenience and peace of mindHospitals and medical facilities have highly specialized access needs that

drive some of the toughest building codes in North America. In these

facilities, patients must be moved safely and often swiftly. Extra safeguards

must be in place related to fire, smoke, wind, security and dozens of other

critical considerations. Each facility must also host hundreds and even

thousands of staff and visitors that pass through its doors each day.

And it must do all of that efficiently in a 24/7 environment where

the doors are never closed. That is health care today. And that is

the world of Horton Automatics, the industry leader in door

systems for hospitals, out-patient care clinics, nursing

homes and other medical facilities.

“We are glad to have collaborated with Horton Automatics on the

SouthwestWashington Medical Center project. Not only did Horton meet

stringent time and quality requirements, but they also implemented

aesthetic and superior design that helped us differentiate our offering.”

Leigh Sutphin, PrincipalNBBJ

Client: Southwest Washington Medical Center, Vancouver, Washington(front cover photo)

2

Page 3: Entrance Systems for Health Care

Linear drive operators for slidingdoors provide smooth, quietoperation and long life.

Rugged Corner Block Construction – A Horton Exclusive!Heavy duty rail design with integral corner blocks adds structuralintegrity to all Horton door systems. Mortise-style corner blockconstruction is far superior to mass produced through-bolt panels.

Four #10-24 boltssecure corner blockto horizontal rail

Two Grade 8, 1/4-20bolts secure cornerblock to vertical rail

Concave steel back-up plate engineeredas built-in selflocking device forGrade 8 bolts

Simple adjustments for open-closespeeds and actuation allow Horton swing

door systems to adapt to your facility’schanging needs.

Smooth operatorsPreferred by architects for sleek aesthetics as well as

durability, Horton operators are also the choice of facility

managers for low maintenance. Horton operators meet

virtually any high or low energy access need.

Integrated solutionsCombining Horton doors, controls, sensors and other access

solutions throughout your facility will allow you to reduce

maintenance worries and confusion. Consider an integrated

Horton platform for ultimate continuity in facility design

and management.

Specify Horton quality andreliability for your facilityAmong the top concerns of any health care facility

manager is that a major entrance must be shut down and

traffic re-routed. With Horton long life operators and high

strength doors, you are choosing the most reliable door

systems available. And if service is needed, Horton

distributors are available to fix the problem promptly and

keep your entrances functioning.

Depend on HortonProfessional Service

Did you know that access issues and

properly maintained door systems

are now an important component of

JCAHO* inspections? Ask your Horton

Automatics distributor to provide

regular preventive maintenance that

will help assure swift approval on

this portion of your accreditation.

* Joint Commission on Accreditationof Healthcare Organizations

3

Page 4: Entrance Systems for Health Care

Folding DoorsOur folding doors are used for entrances as

well as corridors that require a wide opening

but cannot accept a conventional door

because of space limitations.

Swing DoorsDesigned for high traffic entrances providing

convenience and reliability. The variety of

header designs will satisfy any architectural

requirement.

Solutionsdesigned tomeet specifichealth careapplicationrequirements.

Main Entrances

Emergency

Administration

Intensive Care

Cardiac Care

Corridors

Department Entrances

Patient Rooms

Pharmacy

Admissions

Accounts Payable

Gift Shop

4

Page 5: Entrance Systems for Health Care

Revolving DoorsTurn an ordinary entrance into an energy-

efficient vestibule system. This large

diameter automatic revolving entrance

easily accommodates mobile beds.

Sliding DoorsOur broad offering of sliding doors gives

you a wide range of choices to meet your

exacting requirements for size, color, and

finish as well as function, grade of

construction and security.

ICU/CCU DoorsPatients are always in full view through

the sliding glass door. The full breakaway

feature allows for all panels to swing out

of the way providing a large opening for

swift removal of patients or equipment.

Fire Rated DoorsOffering the cleanest possible installation

for fire rated applications in hospitals

and other health care facilities requiring

an automated fire door system.

5

Add security plusconvenience for drive-up

or walk-up traffic inpharmacies, labs and

other areas.

Page 6: Entrance Systems for Health Care

Revolving & SlidingDoor Applications

Main Entrances

Emergency

Administration

Grand® large diameter vestibule systemSpacious compartments provide an elegant, energy-efficient entrance up

to 16 ft. in overall diameter to manage high volume traffic needs including

wheel chairs, walkers and even hospital stretchers.

Easily customized with special finishes, metal cladding, roofpanel designs, Segmented® or round wall design as well asextended canopies

Choice of 3- or 4-wing models, all with quiet, smooth operationand emergency egress panels that fold against the core

Constant seal helps control energy costs and eliminates drafts

VistaScan™ electronic sensing system slows or stops the doorwhen objects are within 10" of the wings

Voice messages announce door slowing, resuming speed and“please step forward”

StormLock™ feature for high wind conditions

AutoFlow™ revolving systems rotateon approach, allow reduced speedsetting for wheel chairs

Glass ceilings and other custom touchesadd drama along with function.

Revolving Doors

ARCHITECT TOOLS:Specs - www.hortondoors.com/Specifications/specifications.htmlCAD Files - www.hortondoors.com/Drawing/drawings.html

Selection GuideType Inside Diameter Entry - 3 Wing Entry - 4 Wing

Manual 6' to 8' up to 3' 9 1⁄8" up to 5' 7 15⁄16"

Security 6' to 7' — up to 4' 8 13⁄16"

Automatic 9' to 10' up to 4' 7 3⁄8" up to 6' 9 5⁄16"

Segmented® Drum Round DrumOutside Diameter Entry - 3 Wing Entry - 3 Wing

MiniGrand® 11' to 12' up to 5' 3⁄4" up to 5' 2 3⁄16"

Outside Diameter Entry - 3 Wing Entry - 4 Wing

Grand® 12' to 16' up to 7' 3⁄8" up to 10' 7"

Entry

Outside Diameter

E

Wing

W

3-Wing

4-Wing

6

“Horton Automatics

consistently provides

excellent pre-

construction services.

They understand

our clients’ clinical

requirements and

their local

distributor is also

very responsive after

installation to meet

ongoing needs

of the medical

facilities we build.”

Chad R. PaaschProject ManagerM. A. MortensonCompanyMinneapolis, Minnesotawww.mortenson.com

Entry

Outside Diameter

W

Wing

MiniGrand®

The MiniGrand® offers the drum constructionof a Grand® and the center shaft and doorwing construction of an AutoFlow.®

Page 7: Entrance Systems for Health Care

7

Profiler® 2000 linear drive systemThese automatic sliding door systems are used in a wide range of health care

applications, both interior and exterior. Custom-manufactured to your

specifications, they are ADA compliant when properly specified and meet all

construction, safety and security requirements.

Unlimited custom options for size and finish

High strength corner block construction ensures durability fortrouble-free operation

Door panels break out for emergency egress

Advanced microprocessor controls with built-in diagnostics

Dual safety beams for added threshold protection

Selectable operating modes (day/night, hold open,one-way/two-way, partial opening, off)

Sliding Doors

ProSlide™ telescoping doors increaseclear openings by more than 35% inlimited spaces.

Elegant® all-glass system withheavy-duty belt drive system

Type 110

41 3/4"

Type SX-O(O-SX Reverse)

OptionalMuntinBar

24"

48"

SafetyBeams

8

8' to 16'7' to 9'

Type O-SX-SX-O

7

Type SX-O (O-SX Reverse) Type O-SX-SX-O

48"

24"

SafetyBeams

8' to 14'7' to 9'

4

Type 110

Type 110

SafetyBeams

48"

24"

Type SX-X-O(O-X-SX Reverse)

Optional Muntin Bar

O

7' to 12'

T

Selection Guide Breakout OpeningModel Type Unit Width Max Slide Opening Type 110 Type 310

Profiler® Single Slide 7' to 9' 3' to 4' 3' 31⁄2" to 4' 31⁄2" 6' 3" to 8' 3"Bi-part 8' to 16' 3' to 7' 3' 7" to 7' 7" 6' 91⁄2" to 14' 91⁄2"

Elegant® Single Slide 6' to 8' 2' 71⁄2" to 3' 8" 2' 71⁄2" to 3' 8" —Bi-part 8' to 14' 3' 4" to 6' 4" 3' 4" to 6' 4” —

ProSlide™ Half Telescoping 7' to 12' 3' 71⁄2" to 6' 111⁄2" 2' 1" to 3' 9" 5' 91⁄2" to 10' 91⁄2"Telescoping Bi-part 8' to 16' 3' 51⁄2" to 8' 91⁄2" 2' 3" to 4' 11" 5' 101⁄2" to 13' 101⁄2"

Page 8: Entrance Systems for Health Care

Manual SlidingDoor Applications

Intensive Care

Cardiac Care

Profiler-ICU® manual sliding door systemDesigned and built specifically for the critical care environment of ICU/CCU

operations, these multi-function doors keep patients in full view when closed.

The panels also slide as well as swing out to provide maximum clearance for

beds and equipment.

Choice of 2-, 3- or 4-panel designs as well as custom configurations

Trackless design option for easier installation and a smooth floor surface

Engineered with the same strong corner block design as ourautomatic door systems

Recessed pull handles (standard), optional positive latch sets

Selection Guide Breakout OpeningUnit Width Max Slide Opening Type 110 Type 310

Single Slide 7' to 9' 3' to 4' 3' 31⁄2" to 4' 31⁄2" 6' 3" to 8' 3"

Bi-Part 8' to 16' 3' to 7' 3' 7" to 7' 7" 6' 91⁄2" to 12' 91⁄2"

Half-Telescoping 7' to 12' 4' 2" to 7' 6" — 6' 1" to 11' 1"

Multi-access design allows clearmonitoring of the room (top) plussliding access (middle) as well aseasy breakaway (bottom) to movepatients.

Custom corner configuration shown

ICU/CCU Sliding Doors

Up to 16'

Type SX-SO (SO-SX Reverse)

OptionalMuntin Bar

41 3/4"

7' to 9'

Type SO-SX-SX-SO

7'2

1/2"

Type 310

Type 110

Type 310

48"

24"

Type SX-SX-SO(SO-SX-SX Reverse)

T

SafetyBeams

7' to 12'

S

Optional Muntin Bar

7

Up to 16'

41 3/4"

Type SX-O (O-SX Reverse)

OptionalMuntin Bar

7' to 9'

7'2

1/2"

Type O-SX-SX-O T

8

Page 9: Entrance Systems for Health Care

9

Modified door nosings, bottom railsand interlock seals exceeds smokeinfiltration requirements of UL 1784.

Note: Consult factory fornewest configurations.

Profiler-ICU® Smoke Rated manual entrance solutionsThis door series provides flexible access to ICU/CCU patients along with smoke protection

per UL 1784 and NFPA standard 105.

Concealed high temperature weather-sweep and gasket design

Positive latching handle

Low-profile header for superior aesthetics

Slide doors available in trackless or recessed track configurations

SmokeSwing™ doors available in single, equal or unequal pair

Selection Guide Max Slide Opening Max Slide Opening Breakout OpeningUnit Width Type 110 & 310 Type 310 Trackless Type 110 Type 310

Single Slide 7' to 9' 3' to 4' 2' 9" to 3' 9" 3' 31⁄2" to 4' 31⁄2" 6' 3" to 8' 3"

SmokeSwing™ DimensionsDoor Width

Single up to 48"Equal Pair up to 48"Unequal Pair up to 48"

ARCHITECT TOOLS:Specs - www.hortondoors.com/Specifications/specifications.html

CAD Files - www.hortondoors.com/Drawing/drawings.html

Type SX-SO (SO-SX Reverse)

7' to 9'

"2/12'7

OptionalMuntinBar

Type SX-O (O-SX Reverse)

7' to 9'

"2/12'7

41 3/4"

OptionalMuntinBar

U

Unit width

Unit

heig

ht

Type 310

Type 110

SmokeSwing™ Pair

Page 10: Entrance Systems for Health Care

HD-Swing® fire door packageThe all-in-one fire rated steel door system, Series 4900DP is a popular

choice for hospital corridors where maximum clear opening is important.

It is designed for high traffic use and complies with ANSI requirements

for full energy (automatic) operation.

Swing DoorApplications

Entrances

Corridors

Department Barriers

Patient Rooms

Series 4900DP packages include 18-gauge steel doors, frame,exit device and Series 4000 heavy-duty operator

Push-N-Go® function activates the door when pushed, SoftTouch®

reopens door if obstructed during closing

All hardware is factory installed for accurate alignment and timesaving installation.

Selection GuideDoor Width

Single Doors 3' 6" to 4' 3"

Pair of Doors 7' to 8' 6"

Low-profile push bar protrudes only1/2" for double egress doors in fullopen position, 1-1/16" for single orpairs of doors.

One-source solution incorporates a heavyduty operator concealed in the header.

Swing Doors

ARCHITECT TOOLS:Specs - www.hortondoors.com/Specifications/specifications.htmlCAD Files - www.hortondoors.com/Drawing/drawings.html

Header–Vertical Section

Top View

Door Panel with Power Arm

Operator

Wal

l

Door Panel

Operator

Steel Header

10

Page 11: Entrance Systems for Health Care

EasyAccess® low energy handicap operatorThe Series 7000 operator is ideal for new or converted

barrier-free openings per ANSI A117/156.19, ADA and local

building codes. Standard features include:

Automatic opening with button or push plate activation

Easily adjustable opening and closing speeds

Operator can be surface applied or overhead concealed

Push-N-Go® feature, SoftTouch® reversing and obstruction sensing

FoldingAccess® door system

Ideal for hospital corridors and vestibules that

require wide openings in a limited space, these

automatic folding doors incorporate Vista™

sensing technology.

Selection GuideUnit Width Opening Width

Single (2 door panels) 3' 5" to 4' 2' 811⁄16" to 3' 11⁄16"

Pair (4 door panels) 6' to 8' 4' 47⁄8" to 6' 47⁄8"

Emergency breakout

Finger guard at all hinge points

Accommodates 1-way or 2-way traffic

Also available in manual opening stylesfor ICU applications

Folding Doors

Folding DoorApplications

Corridors

Entrances

ICU

HD-Swing® LE low energy heavy duty handicap operator

Ideal for use with heavy doors, HD-Swing 4000LE series operators

exceed handicap access requirements of ANSI A117/A156.19 as

well as demands of high traffic hospital environments. Standard

features include:

Easy switching to full energy (automatic) operation

Heavy duty for larger doors

Choice of in-swing, out-swing, left or right handed operation

Fold Out-Type LHR-RHRFold In-Type LH-RH

6' to 8'

7'6"

Unit

Ht. Optional

MuntinBar

Fold Out-Type RHR (LHR Opposite)Fold In-Type RH (LH Opposite)

41 3/4"

3' 8" to 4'

X

11

Page 12: Entrance Systems for Health Care

Specified for hospital drive-through pharmacies

plus labs, supply rooms and other secure

interior areas, these windows can be equipped

with transaction drawers, bullet resistant

glass, a choice of counter tops and other

custom features.

Fully assembled for easy installation

Auto-close and reverse-on-contact functions

Maximum security locks

Sensor packages

SecurityWindowsAutomatic and manual systems

Setting The Standards For Professional Installation And Service

Horton Automatics brings you the professional support of factory-authorized distributors located throughout North

America. Whether your application involves a single automatic door or a complete hospital access and security plan,

you can expect all phases of the project to be handled professionally and responsively.

Call your Horton Automatics distributor today

for design, specification and and application

assistance. Visit www.hortondoors.com to find

the nearest distributor in your area.

Exterior view - automatic singleslide, flush mount shown

WinScan™ photoelectric beam HipScan™ activating system

Interior view with projectingpanels and roof

Auxiliary pushbuttonactivation

Specify Horton and demand AAADM certified installation.

Horton AutomaticsWorld Headquarters4242 Baldwin BoulevardCorpus Christi, Texas 78405-3399 USA

Phone: 800-531-3111, 361-888-5591Fax: 361-888-6510www.hortondoors.com

Horton Automatics, Ltd.United KingdomUnit A, Hortonwood 31Telford, Shropshire, England TF1-7YZ

Phone: 01952 670169Fax: 01952 670181

A Division ofOverhead Door CorporationA Sanwa Shutter Company Form No. HC1000 ©2007 Horton Automatics Printed in U.S.A.