Contents

A. Preface ............................................................................................................................ 1-3

1. TGL LINE GENERAL DESCRIPTION ..................................................................... 1-4

1.1 Product Options .................................................................................................... 1-4

1.2 Nameplate Information ........................................................................................ 1-5

1.3 Technical data table .............................................................................................. 1-6

1.4 Bar-code system .................................................................................................... 1-9

2. WIRING & REFRIGERATION CYCLE DIAGRAMS, CAPACITY & PRESSURECHARTS ......................................................................................................................... 2-1

2.1 Using TGL Model Air-Conditioner Cooling and Heating Capacity Curves ... 2-1

2.1.1 Cooling and Heating Capacity Curves TGL-9 / DGL - 9 .......................... 2-2

2.1.2 Cooling and Heating Capacity Curves TGL-11 / DGL - 11 ...................... 2-3

2.1.3 Cooling and Heating Capacity Curves TGL-15 / DGL - 15 ...................... 2-4

2.1.4 Cooling and Heating Capacity Curves TGL-20 / DGL - 20 ...................... 2-5

2.1.5 Cooling and Heating Capacity Curves TGL-25 ........................................ 2-6

2.1.6 Cooling and Heating Capacity Curves TGL-30 ........................................ 2-7

2.1.7 System Performance (Pressure) Charts TGL-9 / DGL - 9 ........................ 2-8

2.1.8 System Performance (Pressure) Charts TGL -11 / DGL - 11 ................... 2-9

2.1.9 System Performance (Pressure) Charts TGL -15 / DGL - 15 ................. 2-10

2.1.10 System Performance (Pressure) Charts TGL -20 / DGL - 20 ................. 2-11

2.1.11 System Performance (Pressure) Charts TGL -25 ................................... 2-12

2.1.12 System Performance (Pressure) Charts TGL -30 ................................... 2-13

2.2 Refrigeration Cycle ............................................................................................. 2-14

2.2.1 Refrigeration Cycle TGL -9 .................................................................... 12-4

2.2.3 Refrigeration Cycle TGL -11 ................................................................... 2-15

2.2.4 Refrigeration Cycle TGL -15 .................................................................. 2-16

2.2.5 Refrigeration Cycle TGL-20 ................................................................... 2-17

2.2.6 Refrigeration Cycle TGL -25 .................................................................. 2-18

2.2.7 Refrigeration Cycle TGL -30 .................................................................. 2-19

2.2.8 Refrigeration Cycle DGL - 9 ................................................................... 2-20

2.2.9 Refrigeration Cycle DGL -11 .................................................................. 2-21

2.2.10 Refrigeration Cycle DGL - 15 ................................................................. 2-22

2.2.11 Refrigeration Cycle DGL - 20 ................................................................. 2-23

2.3 ELECTRICAL & WIRING DIAGRAM .......................................................... 2-24

2.3.1 TGL- 9 / TGL 11 / TGL-15 / TGL-20 ..................................................... 2-24

2.3.2 Electrical & Wiring Diagram for TGL-25 ............................................... 2-25

2.3.3 Electrical & Wiring Diagram for TGL-30 ............................................... 2-26

2.3.4 Electrical & Wiring Diagram for DGL-9 / DGL-11 / DGL-15 / DGL-20 ..... 2-27

Page 3: EN_TGL

TGL

1-2

AU

G.

2000

513

0-26

135-

90

A. Preface

INTRODUCTION

The Service Manual for TGL model split air-conditioners provides comprehensive technical

documentation for the equipment.

This manual contains information intended for a variety of uses and is intended for application

engineers, architects, designers and various level service and installation personnel.

This manual includes information on the optional features offered by the TGL series. In addition, it

includes general information for service personnel on split air-conditioners, electrical wiring

diagrams, refrigeration cycle diagrams and cooling & heating capacity curves for the various series

models.

Tadiran reserves the right to change product specifications without prior notice.

Created by:

Alex LIBERMANTechnical SupportInternational Marketing

[email protected]

Page 4: EN_TGL

TGL

1-3

AU

G.

2000

513

0-26

135-

90

1. TGL LINE GENERAL DESCRIPTION

1.1 Product Options

Line: TGLCharacteristics: High Wall Systems

50Hz Models:

Options50Hz Models H CTGL-9 ✔ ✔

TGL-11 ✔ ✔

TGL-15 ✔ ✔

TGL-20 ✔ ✔

1 PHASE TGL-25 ✔ ✔

DGL-30 ✔ ✔

DGL-9 ✔ ✔

DGL-11 ✔ ✔

DGL-15 ✔ ✔

DGL-20 ✔ ✔

H - Heating and Cooling by heat pump.

C - Cooling only (No heat pump).

Page 5: EN_TGL

TGL

1-4

AU

G.

2000

513

0-26

135-

90

1.2 Nameplate Information

Technical information for a specific unit appears on the unit nameplate, which is attached to

the indoor and/or the outdoor units.

(See Figure 1-1: Typical Technical Data Nameplate for 50Hz models,

The 50Hz models Nameplate includes the following information:

MODEL Air-conditioner (A/C) model name.

CLIMATE CLASS Type of climate for which the unit was designated - classified by:

Class A (standard) or Class B (desert conditions < 52°C.)

VOLT/PHASE/Hz A/C power supply, for example: 230/1/50 = 230V/1ph/50Hz.

COS (ϕ) Power factor for the unit.

FUSE Required fuse size (Amp.)

CAPACITORS µF All capacitor values according to this sequence (Compressor capacitor /

Outdoor motor capacitor / Indoor motor capacitor).

REFRIGERANT R-22 Quantity of reXfrigerant charge (grams).

COMPRESSOR Type and Catalogue No. of compressor.

CAPACITY BTU/H Cooling and Heating capacity in Btu/h according to ISO 5151 standard

(1000Btu/h=293W).

CAPACITY W Cooling and Heating capacity in Watts (1000W=3,413Btu/h).

INPUT POWER Power consumption in cooling and heating modes (Watts).

AMPER Current consumption in cooling and heating modes (Amp.).

SERIAL NO. Unit serial number (normally blank, since Bar Code system is used).

Figure 1-1: Typical Technical Data Nameplate for 50Hz Units (Sample).

Page 6: EN_TGL

TGL

1-5

AU

G.

2000

513

0-26

135-

90

1.3 Technical data table

Specifications for APOLLO - TGL 50Hz Models

Model 50Hz TGL-9 TGL-11 TGL-15 TGL-20

Cooling Capacity Btu/hKcal/h(Watt)

7,5001,890

(2,200)

9,7002,450

(2,840)

12,3003,110

(3,960)

14,5003,660

(4,250)

Heating Capacity Btu/hKcal/h(Watt)

7,7001,940

(2,260)

9,8002,475

(2,870)

13,0003,280

(3,860)

14,5003,660

(4,250)

Power Consumption Cooling Watt 740 1030 1,400 1,710

Power Consumption Heating Watt 730 870 1,310 1,640

Operating Current(Cooling/Heating)

Amp. 3.5 / 3.4 4.7 / 4.1 6.2 / 5.7 8.1 / 7.8

EER – Energy Efficiency Ratio Cool 10.1 9.4 8.8 8.5

COP – Coefficient Of Performance Heat 3.1 3.3 2.95 2.6

Moisture Removal l/h 1.0 1.4 1.7 2.0

Power Supply Volt/Hz/ph 220/240V, 50Hz, 1ph

Power Factor ϕ 0.92 0.95 0.98 0.92

Refrigerant Lines - Liquid- Gas- Drain

φ - in

φ - in

φ - mm

1/4" (insulated)3/8" (insulated)16 (insulated)

1/4" (insulated)1/2" (insulated)16 (insulated)

Maximum Piping Length m (ft.) 15 (49’)

Maximum Height Difference m (ft.) 10 (33’)

Time Delay Fuse Amp. 10

Control Mode I.R. Remote Control / Auto.

Temperature Control Microcomputer

A/C Options: C (Cooling only) / H (Heat pump)

Indoor Unit 50Hz TGL-9 TGL-11 TGL-15 TGL-20

Front Panel/Back Panel Color White/Gray

Air Filter 2 Removable/Washable Filters

Air Direction Control Motorized Louver- Horizontal and Downwards / Manual – Right, Left

Dimensions (LxHxD) mm(in)

815 × 260 × 185

(32 3/32 × 10 15/64 × 7 9/32)

Air Flow (Turbo/High/Low) m3/hcfm

510300

680400

Noise Level (Turbo/High/Low) dBA

Net Weight Kg (Lb.) 8.5 (19)

Indoor Fan Motor: Watt 20 20

Speed (Turbo/High/Low) R.P.M. 930 / 800 / 700 1350 / 1050 / 850

Full Load Amperage Amp. 0.6 0.9

Motor Capacitor µF/Volt 1µF / 400V 1µF / 400V

Blower Wheel Type Tangential & Segmentary

Outdoor Unit 50Hz TGL-9 TGL-11 TGL-15 TGL-20

Casing Color Gray

Dimensions (LxHxD) mmin

730 × 540 × 265

28 3/4 × 21 1/4 × 10 7/16

Air Flow (High/Medium/Low) m3/hcfm

Noise Level High/Medium/Low) dBA

Net Weight Kg (Lb.) 31.5 (69) 33 (73) 35 (77) 37 (81)

Fittings Type Flare

Compressor 2PS164D2BA02 SG633GB1-S SH833KC2-U SHZ33LC2-U

Thermal Protector Overload External Internal

Full Load Amperage Amp. 4.0 4.3 6.1 7.6

Locked Rotor Amperage Amp. 18.9 18.0 21.0 36.0

Compressor Capacitor µF/Volt 30µF/400V 35µF/400V 50µF/400V 50µF/400V

Capillary 1×0.059"×45" 1×0.059"×45" 1×0.064”×28” 1×0.070”×35”

R-22 Freon Gas gr. (Oz.) 710 (25.0) 690 (24.3) 1,030 (36.3) 880 (31.0)

Oil for Compressor Type 4GS or compatible

Outdoor Fan Motor: Watt 30 40

Motor Capacitor µF/Volt 1.5µF / 400V 4µF / 400V

Speed (High/Medium/Low) R.P.M. 850 / 700 / 550 920 / 750 / 600

Motor Full Load Amperage Amp. 0.3 0.5

Specifications and performance data are subject to change without notice.

Page 7: EN_TGL

TGL

1-6

AU

G.

2000

513

0-26

135-

90

Specifications for APOLLO - TGL 50Hz Models

Model 50Hz DGL-9 DGL-11 DGL-15 DGL-11/15 *

TGL-11 TGL-15

Cooling Capacity Btu/hKcal/h(Watt)

2 × 7,5002 × 1,890

(2 × 2,200)

2 × 9,7002 × 2,450

(2 × 2,840)

2 × 12,3002 × 3,110

(2 × 3,960)

9,7002,450

(2,840)

12,3003,110

(3,960)

Heating Capacity Btu/hKcal/h(Watt)

2 × 7,7002 × 1,940

(2 × 2,260)

2 × 9,8002 × 2,475

(2 × 2,870)

2 × 13,0002 × 3,280

(2 × 3,860)

9,8002,475

(2,870)

13,0003,280

(3,860)

Power Consumption Cooling Watt 2 × 740 2 × 1030 2 × 1,400 1030 1,400

Power Consumption Heating Watt 2 × 730 2 × 870 2 × 1,310 870 1,310

Operating Current(Cooling/Heating)

Amp. 2 × (3.5 / 3.4) 2 × (4.7 / 4.1) 2 × (6.2 / 5.7) 4.7 / 4.1 6.2 / 5.7

EER – Energy Efficiency Ratio Cool 2 × 10.1 2 × 9.4 2 × 8.8 9.4 8.8

COP– Coefficient Of Performance Heat 2 × 3.1 2 × 3.3 2 × 2.95 3.3 2.95

Moisture Removal l/h 2 × 1.0 2 × 1.4 2 × 1.7 1.4 1.7

Power Supply Volt/Hz/ph 2 × 220/240V, 50Hz, 1ph 2 × 220/240V, 50Hz, 1ph

Power Factor ϕ 2× 0.96 2× 0.95

Refrigerant Lines - Liquid- Gas- Drain

φ - in

φ - in

φ - mm

2×1/4" (insulated)2×3/8" (insulated)2×16 (insulated)

2×1/4"(insulated)

2×1/2"(insulated)

2×16(insulated)

1/4"(insulated)

3/8"(insulated)

16 (insulated)

1/4" (insulated)1/2" (insulated)16 (insulated)

Maximum Piping Length m (ft.) 2× 15 (2× 49’)

Maximum Height Difference m (ft.) 2× 10 (2× 33’)

Time Delay Fuse Amp. 2× 10 10 10

Control Mode I.R. Remote Control / Auto.

Temperature Control Microcomputer

A/C Options: C (Cooling only) / H (Heat pump)

Indoor Unit 50Hz DGL-9 DGL-11 DGL-15 DGL-11/15 *

Front Panel/Back Panel Color White/Gray

Air Filter 2 Removable/Washable Filters

Air Direction Control Motorized Louver- Horizontal and Downwards / Manual - Right, Left

Dimensions (LxHxD) mm(in)

2 × 815 × 260 × 1852 × (32 3/32 × 10 15/64 × 7 9/32)

Air Flow(Turbo/High/Low)

m3/hcfm

2 ×2 ×

Noise Level(Turbo/High/Low)

dBA 2 ×

Net Weight Kg (Lb.) 2× 8.5 (2× 19)

Indoor Fan Motor: Watt 2 × 20 2 × 20 2 × 20

Speed (Turbo/High/Low) R.P.M. 2 × 930 / 800 / 700 2×1350/1050/850

2 × 930 / 800 / 700

Full Load Amperage Amp. 2 × 0.6 2 × 0.9 2 × 0.6

Motor Capacitor µF/Volt 2 × 1µF / 400V 2 × 1µF /400V

2 × 1µF / 400V

Blower Wheel Type Tangential & Segmentary

Outdoor Unit 50Hz DGL-9 DGL-11 DGL-15 DGL-11/15 *

Casing Color Gray

Dimensions (LxHxD) mmin

1100 × 640 × 32043 5/16 × 25 3/16 × 12 19/32

Air Flow (High/Medium/Low) m3/hcfm

3,910 / 30602,300 / 1,800

Noise Level (High/Medium/Low) dBA 52 / 49

Net Weight Kg (Lb.) 75 (165)

Fittings Type Flare

Compressor 2×SG633GB1-S 2×SG633GB1-S

2×SH833KC2-

U

SG633GB1-S SH833KC2-U

Thermal Protector Internal Overload

Full Load Amperage Amp. 4.3 4.3 6.1 4.3 6.1

Locked Rotor Amperage Amp. 18.0 18.0 21.0 18.0 21.0

Compressor Capacitor µF/Volt 35µF/400V 35µF/400V 50µF/400V 35µF/400V 50µF/400V

Capillary 2× 1×0.059"×45" 2×1×0.059"×45"

2×1×0.064"×32"

R-22 Freon Gas gr. (Oz.) 2×860 (2×30.3) 2×860 (2×30.3) 2×980(2×34.6)

Oil for Compressor Type 4GS or compatible

Outdoor Fan Motor: HP 1/5

Motor Capacitor µF/Volt 5µF / 400V

Speed (High/Medium/Low) R.P.M. 900 / 700 / 500

Motor Full Load Amperage Amp. 1.3

Specifications and performance data are subject to change without notice. * DGL-11/15 is future model only (not exist at the moment).

Page 8: EN_TGL

TGL

1-7

AU

G.

2000

513

0-26

135-

90

Specifications for APOLLO - TGL 50Hz Models

Model 50Hz TGL-25 TGL-30 DGL-20

Cooling Capacity Btu/hKcal/h(Watt)

18,5004,670

(5,420)

24,0006,060

(7,033)

2 × 14,5002 × 3,660

(2 × 4,250)

Heating Capacity Btu/hKcal/h(Watt)

20,0005,050

(5,860)

26,0006,565

(7,620)

2 × 14,5002 × 3,660

(2 × 4,250)

Power Consumption Cooling Watt 2,080 2,670 2 × 1,710

Power Consumption Heating Watt 1,720 2,310 2 × 1,640

Operating Current (Cooling/Heating) Amp. 9.1 / 7.6 11.8 / 10.6 2 × (8.1 / 7.8)

EER – Energy Efficiency Ratio Cool 8.9 9.0 2 × 8.5

COP– Coefficient Of Performance Heat 3.4 3.3 2 × 2.6

Moisture Removal l/h 2.2 2.8 2 × 2.0

Power Supply Volt/Hz/ph 220/240V 50Hz 1ph 2 × 220/240V 50Hz 1ph

Power Factor ϕ 0.98 2 × 0.92

Refrigerant Lines - Drain Liquid/GasLines

φ - mm (in)φ - Inch

16 (5/8)1/4 ;1/2 (insulated)

16 (5/8)3/8 ; 5/8 (insulated)

2 × 16 (5/8)2 × 1/4 ;1/2 (insulated)

Minimal insulation thickness mm (in) 7 (9/32) 7 (9/32) 2 × 7 (9/32)

Maximum Piping Length m (ft) 15 (49’) 2 × 15 (2× 49’)

Maximum Height Difference m (ft) 10 (33’) 2 × 10 (2× 33’)

Time Delay Fuse Amp. 16 20 2 × 10

Control Mode I.R. Remote Control / Auto.

Temperature Control Microcomputer

A/C Options: C (Cooling only) / H (Heat pump)

Indoor Unit 50Hz TGL-25 TGL-30 DGL-20Front Panel/Back Panel Color White/White White/Gray

Air Filter Removable/Washable Filters

Air Direction Control Motorized Louver- Horizontal and Downwards / Manual – Right, Left

Dimensions (LxHxD) mmin

1,080 × 295 × 18542 1/2 × 11 5/8 × 7 9/32

815 × 260 × 185(32 3/32 × 10 15/64 × 7 9/32)

Air Flow (Turbo/High/Low) m3/h

cfm1,020600

1,270750

2 × 6802 × 400

Noise Level (Turbo/High/Low) dBA

Net Weight Kg. (Lb.) 8.5 (19) 12.5 (28) 2 × 8.5 (2 × 19)

Indoor Fan Motor: Watt 2 × 20

Speed (Turbo/High/Low) R.P.M. 2 × 1350 / 1050 / 850

Full Load Amperage Amp. 2 × 0.9

Motor Capacitor µF/Volt µF / 400V µF / 400V 2 × 1µF / 400V

Electric Heater Watt None

Blower Wheel Type Tangential, Segmentary

Outdoor Unit 50Hz TGL-25 TGL-30 DGL-20

Casing Color Gray

Dimensions (LxHxD) Mmin

730 × 540 × 26528 3/4 × 21 1/4 × 10

7/16

900 × 640 × 32035 7/16 × 25 3/16 × 12

19/32

1,100 × 640 × 32043 5/16 × 25 3/16 × 12 19/32

Air Flow (High/Medium/Low) m3/h

cfm

Noise Level (High/Medium/Low) dBA

Net Weight Kg (Lb.) 38.5 (85) 65 (143) 75 (165)

Fittings Type Flare

Compressor SHW33TC4-U H29B32UABKA 2× 2KS252D3BA02

Thermal Protector Internal Overload

Full Load Amperage Amp. 9.3 12.4 2× 6.2

Locked Rotor Amperage Amp. 49.0 76.0 2× 29.0

Compressor Capacitor µF/Volt 50µF/400V 40µF/400V 2× 40µF/400V

Capillary 2× 0.059” ×30” +1 × 0.054” ×10”

2 × 0.064” × 32” 2× 1×0.070"×38"

R-22 Freon Gas gr. (Oz.) 1,300 (45.9) 1,500 (52.9) 2 × 1,180 (2 × 41.6)

Oil for Compressor Type 4GS or Compatible 3GS or Compatible 4GS or Compatible

Outdoor Fan Motor: HP 40 1/5 1/5

Motor Capacitor µF/Volt 4µF / 400V 5µF / 400V 5µF / 400V

Speed (High/Medium/Low) R.P.M. 920 / 750 / 600 900 / 700 / 500 900 / 700 / 500

Motor Full Load Amperage Amp. 0.5 1.3 1.3

Specifications and performance data are subject to change without notice.

Page 9: EN_TGL

TGL

1-8

AU

G.

2000

513

0-26

135-

90

1.4 Bar-code system

Finished goods (packed evaporator or condenser) are labeled by Bar Code for easy identifi-cation of product configuration and storage.Each unit has Bar Code labels as shown below, one on each side of the packed unit andsmall labels (with unit serial number only) are located on each unit (near the nameplate onthe evaporator, beneath the valves and in the connection box of the condenser).The structure of the Bar Code label:A. Complete unit name, for example: GFL-2020C (GFL-2020 model without heat

pump).B. Important components (up to 2 lines) about the specific unit, for example: CARRIER

MEXICO, NEW R.C, TAC-404.C. Unit catalog number/order number, for example: CATALOG NO. 51382057712/

880472 (prefix of 5138 for evaporator and 5139 for condenser).D. Unit serial number, for example: S/N 2248119059 = 22 - for factory use; 48 - 1998;

059185 - running (serial) number.E. Tadiran order number, for example: 880472 = 88 - 1998; 0 group; 472 - order running

number.F. Small S/N cables (X3).An additional Bar Code label displays the PALLET NO. (see next page) and is used forstorage only.

Figure 1-2: Typical Evaporator/Condenser Unit Bar Code Identification Label

A

B

C

D

F

E

Page 10: EN_TGL

TGL

1-9

AU

G.

2000

513

0-26

135-

90

Figure 1-3: Typical Pallet Bar Code Label

Page 11: EN_TGL

TGL

2-1

JULY

200

0 51

30-2

6135

-90

2. WIRING & REFRIGERATION CYCLE DIAGRAMS, CAPACITY &PRESSURE CHARTS

2.1 Using TGL Model Air-Conditioner Cooling and Heating Capacity CurvesUsing the Cooling and Heating Capacity Curves.

The Cooling and Heating Characteristics curves are mainly intented for use by air conditioning

engineers as an aid in designing systems and in determining the capacity and number of units

required at a given site.

The air conditioner capacities were determined in accordance with ISO 5151 and ARI 210/

240 standards operating conditions:

Design parameters for a given site are often different than the standard conditions. Therefore,

the design engineer should use the capacity charts which follow to calculate the capacity of

the air conditioners under the intended working conditions, in order to optimize the selection

of air conditioner units for use at a particular site.

Notes:1) Capacities tested and rated in accordance with ISO-5151 standard.

Cooling Conditions: 35°C (95°F) DB and 24°C (75°F) WB outdoor ;

27°C (81°F) DB and 19°C (66°F) indoor.

2) Capacities tested and rated in accordance with ISO-5151 standard. Heating Conditions: 7°C (45°F) DB and 6°C (43°F) WB outdoor ;

20°C (68°F) DB and 15°C (59°F) WB indoor.

Page 12: EN_TGL

TGL

2-2

JULY

200

0 51

30-2

6135

-90

2.1.1 Cooling and Heating Capacity Curves TGL-9 / DGL - 9

* OUTDOOR R.H. = 70% INDOOR TEMP. = 70 °F AIR SPEED:

* OUTDOOR R.H. = 40% INDOOR R.H. = 51%

INDOOR TEMP. = 80 °F MAX. AIR SPEED: TURBO

TURBO

COOLING CAPACITY

HEATING CAPACITY

OUTDOOR TEMP. [°C]

OUTDOOR TEMP. [°F]

OUTDOOR TEMP. [°C]

OUTDOOR TEMP. [°F]

CA

PAC

ITY

[B

tu/H

]C

APA

CIT

Y [

Btu

/H]

[Btu/H]

[Btu/H]

5000

5500

6000

6500

7000

7500

8000

8500

24 28 32 36 40 44

0

2000

4000

6000

8000

10000

12000

-15 -10 -5 0 5 10 15

Page 13: EN_TGL

TGL

2-3

JULY

200

0 51

30-2

6135

-90

2.1.2 Cooling and Heating Capacity Curves TGL-11 / DGL - 11

* OUTDOOR R.H. = 70% INDOOR TEMP. = 70 °F AIR SPEED:

* OUTDOOR R.H. = 40% INDOOR R.H. = 51%

INDOOR TEMP. = 80 °F MAX. AIR SPEED: TURBO

TURBO

COOLING CAPACITY

HEATING CAPACITY

OUTDOOR TEMP. [°C]

OUTDOOR TEMP. [°F]

OUTDOOR TEMP. [°C]

OUTDOOR TEMP. [°F]

CA

PAC

ITY

[B

tu/H

]C

APA

CIT

Y [

Btu

/H]

[Btu/H]

[Btu/H]

8000

8500

9000

9500

10000

10500

24 28 32 36 40 44

0

2000

4000

6000

8000

10000

12000

14000

-15 -10 -5 0 5 10 15

Page 14: EN_TGL

TGL

2-4

JULY

200

0 51

30-2

6135

-90

2.1.3 Cooling and Heating Capacity Curves TGL-15 / DGL - 15

* OUTDOOR R.H. = 70% INDOOR TEMP. = 70 °F AIR SPEED:

* OUTDOOR R.H. = 40% INDOOR R.H. = 51%

INDOOR TEMP. = 80 °F MAX. AIR SPEED: TURBO

TURBO

COOLING CAPACITY

HEATING CAPACITY

OUTDOOR TEMP. [°C]

OUTDOOR TEMP. [°F]

OUTDOOR TEMP. [°C]

OUTDOOR TEMP. [°F]

CA

PAC

ITY

[B

tu/H

]C

APA

CIT

Y [

Btu

/H]

[Btu/H]

[Btu/H]

10000

10500

11000

11500

12000

12500

13000

13500

24 28 32 36 40 44

0

2000

4000

6000

8000

10000

12000

14000

16000

18000

20000

-15 -10 -5 0 5 10 15

Page 15: EN_TGL

TGL

2-5

JULY

200

0 51

30-2

6135

-90

2.1.4 Cooling and Heating Capacity Curves TGL-20 / DGL - 20

Page 16: EN_TGL

TGL

2-6

JULY

200

0 51

30-2

6135

-90

2.1.5 Cooling and Heating Capacity Curves TGL-25

Page 17: EN_TGL

TGL

2-7

JULY

200

0 51

30-2

6135

-90

2.1.6 Cooling and Heating Capacity Curves TGL-30

Page 18: EN_TGL

TGL

2-8

JULY

200

0 51

30-2

6135

-90

2.1.7 System Performance (Pressure) Charts TGL-9 / DGL - 9

Page 19: EN_TGL

TGL

2-9

JULY

200

0 51

30-2

6135

-90

2.1.8 System Performance (Pressure) Charts TGL -11 / DGL - 11

Page 20: EN_TGL

TGL

2-10

JULY

200

0 51

30-2

6135

-90

2.1.9 System Performance (Pressure) Charts TGL -15 / DGL - 15

COOLING DISCHARGE PRESSURE

OUTDOOR TEMP. [°C]

COOLING SUCTION PRESSURE

OUTDOOR TEMP. [°C]

COOLING INDOOR AIR dT

OUTDOOR TEMP. [°C]

HEATING SUCTION PRESSURE

OUTDOOR TEMP. [°C]

HEATING INDOOR AIR dT

OUTDOOR TEMP. [°C]

HEATING DISCHARGE PRESSURE

OUTDOOR TEMP. [°C]

dT [

°C]

dT [

°C]

PR

ESS

UR

E [

psi]

PR

ESS

UR

E [

psi]

PR

ESS

UR

E [

psi]

PR

ESS

UR

E [

psi]

OUTDOOR R.H. =INDOOR TEMP. =AIR SPEED:

77%20°CTURBO

*OUTDOOR R.H. =INDOOR R.H. =INDOOR TEMP. =AIR SPEED:

40%47%20°CTURBO

*

0

50

100

150

200

250

300

350

400

24 28 32 36 40 44

60

62

64

66

68

70

72

74

24 28 32 36 40 44

12

12.2

12.4

12.6

12.8

13

13.2

13.4

13.6

13.8

24 28 32 36 40 44

0

50

100

150

200

250

300

350

-10 -5 0 5 10 15

0

10

20

30

40

50

60

70

80

-10 -5 0 5 10 15

0

5

10

15

20

25

-10 -5 0 5 10 15

Page 21: EN_TGL

TGL

2-11

JULY

200

0 51

30-2

6135

-90

2.1.10 System Performance (Pressure) Charts TGL -20 / DGL - 20

Page 22: EN_TGL

TGL

2-12

JULY

200

0 51

30-2

6135

-90

2.1.11 System Performance (Pressure) Charts TGL -25

Page 23: EN_TGL

TGL

2-13

JULY

200

0 51

30-2

6135

-90

2.1.12 System Performance (Pressure) Charts TGL -30

Page 24: EN_TGL

TGL

2-14

JULY

200

0 51

30-2

6135

-90

2.2 Refrigeration Cycle

2.2.1 Refrigeration Cycle TGL -9

1 ROWS2 CIRCUITS17 F.P.I.24 PLAIN TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7mm

INDOOR COIL

MOTOR30 Watt850/700/550 RPM

PROPELLERPLASTIC4 BLADES380 mm D. BLOWERS

QTY: 1DIAM. : 100 mmWIDTH : 620 mmBLADES : 35

MOTOR20 Watt930 - 800 -700 RPM

AIR

OUT

AIR

OUT

L L

L'

V

V

V'

AIR

IN

AIR

OUT

MATSUSHITA

2P14C8

7,600 BTU/h1,920 Kcal/h750 WATTS10.1 EER

V

V

D C

S

ERV

V'

3/8"

1/4"

AIR

IN

AIR

IN

1 X 0.059" X 45"

CAPILLARY

2 WASHABLEAIR

FILTERS

MU

FF

LER

Page 25: EN_TGL

TGL

2-15

JULY

200

0 51

30-2

6135

-90

2.2.3 Refrigeration Cycle TGL -11

1 ROWS2 CIRCUITS17 F.P.I.24 PLAIN TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7 mm

INDOOR COIL

MOTOR30 Watt850/700/550 RPM

PROPELLERPLASTIC4 BLADES380 mm D. BLOWERS

QTY: DIAM. : WIDTH : BLADES :

MOTOR20 Watt930 - 800 -700 RPM

AIR

OUT

AIR

OUT

L L

L'

V

V

V'

AIR

IN

AIR

OUT

HITACHI

SG633GB1-S

9,420 BTU/h2,380 Kcal/h920 WATTS10.25 EER

V

V

D C

S

ERV

V'

3/8"

1/4"

AIR

IN

AIR

IN

1 X 0.059" X 45"

CAPILLARY

2 WASHABLEAIR

FILTERS

MU

FF

LER

1100 mm620 mm35

Page 26: EN_TGL

TGL

2-16

JULY

200

0 51

30-2

6135

-90

2.2.4 Refrigeration Cycle TGL -15

2 ROWS3 CIRCUITS17 F.P.I.48 PLAIN TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7mm

INDOOR COIL

MOTOR30 Watt850/700/550 RPM

PROPELLERPLASTIC4 BLADES380 mm D. BLOWERS

QTY: DIAM. : WIDTH : BLADES :

MOTOR20 Watt1350 - 1050 -850 RPM

AIR

OUT

AIR

OUT

L L

L'

V

V

V'

AIR

IN

AIR

OUT

HITACHI

SH833KC2-U

13,240 BTU/h3,345 Kcal/h1,240 WATTS10.65 EER

V

V

D C

S

ERV

V'

1/2"

1/4"

AIR

IN

AIR

IN

1 X 0.064" X 28"

CAPILLARY

2 WASHABLEAIR

FILTERS

MU

FF

LER

1100 mm620 mm35

Page 27: EN_TGL

TGL

2-17

JULY

200

0 51

30-2

6135

-90

2.2.5 Refrigeration Cycle TGL-20

2 ROWS3 CIRCUITS17 F.P.I.48 GROOVED TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7 mm

INDOOR COIL

MOTOR40 Watt920/750/600 RPM

PROPELLERPLASTIC4 BLADES380 mm D. BLOWERS

QTY: DIAM. :WIDTH :BLADES :

MOTOR20 Watt1350 - 1050 -850 RPM

AIR

OUT

AIR

OUT

L L

L'

V

V

V'

AIR

IN

AIR

OUT

HITACHI

SHZ33LC2-U

16,450 BTU/h4,150 Kcal/h1,630 WATTS10.1 EER

V

V

D C

S

ERV

V'

1/2"

1/4"

AIR

IN

AIR

IN

1 X 0.070" X 35"

CAPILLARY

2WASHABLE

AIRFILTERS

MU

FF

LER

1100 mm620 mm35

Page 28: EN_TGL

TGL

2-18

JULY

200

0 51

30-2

6135

-90

2.2.6 Refrigeration Cycle TGL -25

3 ROWS4 CIRCUITS17 F.P.I.72 GROOVED TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 PARTS)5 CIRCUITS17 F.P.I.30 GROOVED TUBES 7 mm

INDOOR COIL

MOTOR1/5 HP920/750/600 RPM

PROPELLERPLASTIC4 BLADES380 mm D. BLOWERS

QTY: DIAM. : WIDTH : BLADES :

MOTOR1100 - 900 -700 RPM

AIR

OUT

AIR

OUT

L L

L'

V

V

V'

AIR

IN

AIR

OUT

HITACHI

SHW33TC4-U

20,440 BTU/h5,160 KCAL/h1,990 WATTS10.3 EER

V

V

D C

S

ERV

V'

MU

FF

LER

1/2"

1/4"

AIR

IN

AIR

IN

2 X 0.059" X 30"

CAPILLARY

3WASHABLE

AIRFILTERS

1x0.064"x10"

1100 mm620 mm35

1 X 0.054" X 10"CAPILLARY

CHECKVALVE

Page 29: EN_TGL

TGL

2-19

JULY

200

0 51

30-2

6135

-90

2.2.7 Refrigeration Cycle TGL -30

2 ROWS4 CIRCUITS17 F.P.I.56 PLAIN TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 PARTS)5 CIRCUITS17 F.P.I.30 GROOVED TUBES 7 mm

INDOOR COIL

MOTOR1/5 HP900/700/500 RPM

PROPELLERPLASTIC6 BLADES500 mm D. BLOWERS

QTY: DIAM. : WIDTH : BLADES :

MOTOR1350 - 1050 -850 RPM

AIR

OUT

AIR

OUT

L

L'

V

V

V'

AIR

IN

AIR

OUT

BRISTOL COMP.

H29B32U

27,500 BTU/h6,945 Kcal/h2,570 WATTS10.7 EER

V

V

D C

S

ERV

V'

MU

FF

LER

5/8"

3/8"

AIR

IN

AIR

IN

L

2 X 0.064" X 32"

CAPILLARY

3WASHABLE

AIRFILTERS

1100 mm620 mm35

Page 30: EN_TGL

TGL

2-20

JULY

200

0 51

30-2

6135

-90

2.2.8 Refrigeration Cycle DGL - 9

1/4"

2 ROWS2 X 3 CIRCUITS17 F.P.I.56 PLAIN TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7 mm

2 X INDOOR COIL

MOTOR1/5 HP900/700/500 RPM

PROPELLERPLASTIC6 BLADES500 mm D.

MOTOR20 Watt930 - 800 -700 RPM

AIR

OUT

AIR

OUT

L

V

V'

AIR

IN

AIR

OUT

V

V

D C

S

ERV

V'

MU

FF

LER

3/8"

1/4"

AIR

IN

AIR

IN

1 X 0.059" X 45"

CAPILLARY BLOWERSQTY: DIAM. : WIDTH : BLADES :

MOTOR20 Watt930 - 800 -700 RPM

AIR

OUT

AIR

OUTV

AIR

IN

AIR

IN

D C

S

E

MU

FF

LER

L

1 X 0.059" X 45"

CAPILLARY

3/8"

2 WASHABLEAIR

FILTERS

2 WASHABLEAIR

FILTERS

HITACHISG633GB1-S

9,420 BTU/h2,380 Kcal/h920 WATTS10.25 EER

HITACHISG633GB1-S

9,420 BTU/h2,380 Kcal/h920 WATTS10.25 EER

1100 mm620 mm35

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

Page 31: EN_TGL

TGL

2-21

JULY

200

0 51

30-2

6135

-90

2.2.9 Refrigeration Cycle DGL -11

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

1/4"

2 ROWS2 X 3 CIRCUITS17 F.P.I.56 PLAIN TUBES 7 mm

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7 mm

2 X INDOOR COIL

MOTOR1/5 HP900/700/500 RPM

PROPELLERPLASTIC6 BLADES500 mm D.

MOTOR20 Watt930 - 800 -700 RPM

AIR

OUT

AIR

OUT

L

V

V'

AIR

IN

AIR

OUT

V

V

D C

S

ERV

V'

MU

FF

LER

3/8"

1/4"

AIR

IN

AIR

IN

1 X 0.059" X 45"

CAPILLARY

MOTOR20 Watt930 - 800 -700 RPM

AIR

OUT

AIR

OUTV

AIR

IN

AIR

IN

D C

S

E

MU

FF

LER

L

1 X 0.059" X 45"

CAPILLARY

3/8"

2 WASHABLEAIR

FILTERS

2 WASHABLEAIR

FILTERS

HITACHISG633GB1-S

9,420 BTU/h2,380 Kcal/h920 WATTS10.25 EER

HITACHISG633GB1-S

9,420 BTU/h2,380 Kcal/h920 WATTS10.25 EER

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

Page 32: EN_TGL

TGL

2-22

JULY

200

0 51

30-2

6135

-90

1/4"

3 ROWS2 X 3 CIRCUITS17 F.P.I.84 PLAIN TUBES

OUTDOOR COIL

2 ROWS (3 Parts)3 CIRCUITS17 F.P.I.24 GROOVED TUBES 7 mm

2 X INDOOR COIL

MOTOR1/5 HP900/700/500 RPM

PROPELLERPLASTIC6 BLADES500 mm D.

MOTOR20 Watt1350 - 1050 -850 RPM

AIR

OUT

AIR

OUT

L

V

V'

AIR

IN

AIR

OUT

V

V

D C

S

ERV

V'

MU

FF

LER

1/2"

1/4"

AIR

IN

AIR

IN

1 X 0.064" X 32"

CAPILLARY

MOTOR20 Watt1350 - 1050 -850 RPM

AIR

OUT

AIR

OUTV

AIR

IN

AIR

IN

D C

S

E

MU

FF

LER

L

1 X 0.064" X 32"

CAPILLARY

1/2"

2WASHABLE

AIRFILTERS

2WASHABLE

AIRFILTERS

HITACHISH833KC2-U

13,240 BTU/h3,345 Kcal/h1,240 WATTS10.65 EER

HITACHISH833KC2-U

13,240 BTU/h3,345 Kcal/h1,240 WATTS10.65 EER

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

2.2.10 Refrigeration Cycle DGL - 15

Page 33: EN_TGL

TGL

2-23

JULY

200

0 51

30-2

6135

-90

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

1/4"

2 ROWS2 X 3 CIRCUITS17 F.P.I.84 PLAIN TUBES

OUTDOOR COIL

2 ROWS3 CIRCUITS17 F.P.I.24 PLAIN TUBES

2 X INDOOR COIL

MOTOR1/5 HP900/700/500 RPM

PROPELLERPLASTIC6 BLADES500 mm D.

MOTOR20 Watt1350 - 1050 -850 RPM

AIR

OUT

AIR

OUT

L

V

V'

AIR

IN

AIR

OUT

MATSUSHITA

2KS252

14,570 BTU/h3,680 Kcal/h1,400 WATTS10.4 EER

V

V

D C

S

ERV

V'

MU

FF

LER

1/2"

1/4"

AIR

IN

AIR

IN

1 X 0.070" X 38"

CAPILLARY

MOTOR20 Watt1350 - 1050 -850 RPM

AIR

OUT

AIR

OUTV

AIR

IN

AIR

IN

MATSUSHITA

2KS252

14,570 BTU/h3,680 Kcal/h1,400 WATTS10.4 EER

D C

S

E

MU

FF

LER

L

1 X 0.070" X 38"

CAPILLARY

1/2"

2 WASHABLEAIR

FILTERS

2 WASHABLEAIR

FILTERS

BLOWERSQTY: DIAM. : WIDTH : BLADES :

1100 mm620 mm35

2.2.11 Refrigeration Cycle DGL - 20

Page 34: EN_TGL

TGL

2-24

JULY

200

0 51

30-2

6135

-90

Important Note: Always refer to specific electrical diagram on the unit.

2.3 ELECTRICAL & WIRING DIAGRAM

2.3.1 TGL- 9 / TGL 11 / TGL-15 / TGL-20

Page 35: EN_TGL

TGL

2-25

JULY

200

0 51

30-2

6135

-90

Important Note: Always refer to specific electrical diagram on the unit.

2.3.2 Electrical & Wiring Diagram for TGL-25

Page 36: EN_TGL

TGL

2-26

JULY

200

0 51

30-2

6135

-90

Important Note: Always refer to specific electrical diagram on the unit.

2.3.3 Electrical & Wiring Diagram for TGL-30

Page 37: EN_TGL

TGL

2-27

JULY

200

0 51

30-2

6135

-90

Important Note: Always refer to specific electrical diagram on the unit.

2.3.4 Electrical & Wiring Diagram for DGL-9 / DGL-11 / DGL-15 / DGL-20