Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Ensure
in your resultswith cost-effective proof of performance and calibration
confidence
Functional Verification Service
Certified functional verification for your Agilent LC, GC, GC/MS and UV-Vis systems Today’s demanding quality standards make it tougher than ever for chemical, food and flavors, forensics, and contract testing labs to provide relevant proof of system performance and calibration – especially those that may be working under ISO 17025 or similar quality management conditions.
Agilent’s Functional Verification Service (FVS) delivers a factory recommended, metrology-based testing suite for your LC, GC, GC/MS and UV-Vis systems. It provides confirmation of the accuracy and calibration of critical system functions, from an industry leader in the regulated pharmaceutical sector – a leader that’s been ranked #1 in compliance services since 1995. In just a few hours, you’ll have full documentation and certification to support your quality initiatives or accreditation status.
ISO/IEC 17025 is used to assess labs that seek accreditation status. Its many guidelines include requirements that equipment be calibrated to establish that it meets the laboratory’s specification requirements.
Functional Verification Service – confidence in the reliability of your resultsMetrology testing of temperature, pressure, flow, wavelength, noise and drift, and other system-specific parameters
Certificate of performance provides evidence that your systems meet the accuracy and calibration specifications of your quality or ISO 17025 accreditation initiatives
Global lab-to-lab consistency thanks to Agilent’s standardized testing protocols and validated methodology
Cost-effective verification to assure confidence in the quality and reliability of your results
Additional optional tests available, increasing the flexibility of testing scope according to your needs
Information, descriptions, and specifications in this publication are subject to change without notice. © Agilent Technologies, Inc. 2013 Printed in the USA March 22, 20135990-3763EN
Learn more about Functional Verification Service at www.agilent.com/chem/functional-verification or talk to your Agilent Representative.
Functional Verification Service for a typical LC with UV detector includes these essential metrology tests: • Record of model, serial number,
and firmware for each module • Detector lamp wavelength
accuracy test• LC Pump flow accuracy and
precision tests • Gradient performance test of binary
& quaternary pumps to provide delay volume information and test of composition accuracy, noise, and drift
• Detector signal noise and drift test • Column compartment temperature
tests for accuracy and stability • Accuracy check of auto sampler
tray temperature • Printing of Verification Certificate
Functional Verification Service for a typical UV-Vis system includes these essential metrology tests: • Record of model, serial number,
and firmware for each module • Wavelength Accuracy – Source Line,
Mercury Line or Holmium Oxide in Perchloric acid (model-specific).
• Wavelength Reproducibility• Photometric Noise• Baseline Flatness• Printing of Verification Certificate
Agilent’s Functional Verification Service is ideal for those who may be working under ISO 17025 or similar quality management conditions. Its traceable tools, validated test equipment and certified reference standards ensure your LC, GC, GC/MS and UV-Vis instruments perform to engineering specification. Additional Preventive Maintenace (PM) is available to ensure they’re maintained according to the manufacturer recommendations.
Support your accreditation status confidently with Agilent’s Functional Verification Service
Functional Verification Service for a typical GC with Flame Ionization Detector (FID) or Thermal Conductivity Detector (TCD) includes these essential metrology tests: • Record of model, serial number,
and firmware for each module • Seven-function check – checking
safety of installation, diagnostic check, hydrogen safety cut-off, oven thermal safety cut-off
• GC oven temperature accuracy and stability test
• Inlet pressure decay and accuracy tests
• GC heated zones temperature accuracy tests (including headspace if present)
• Detector flow accuracy test • Detector signal noise and drift test • Printing of Verification Certificate
Functional Verification Service for a typical GC/MS includes the essential metrology tests for GC (listed above), as well as: • System tune• RFPA (radio frequency power
amplifier) Test• Log Amp test
CONTACT AGILENT SALES AND SERVICE CENTERS
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Australia – Tel: 1-800-802-402
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Brazil – Tel: 0800-7281405
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Canada – Tel: 800-227-9770
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
China – Tel: 800-820-3278 6
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
France – Tel: 0810 446 446FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Germany – Tel: 0800-603 1000
India – Tel: 18001801517FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Italy – Tel: 1-800 012 575FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Japan – Tel: 0120-477-111 or 042-656-7882
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Korea – Tel: 080-004-5090FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Mexico – Tel: (55) 1253 2153 or 01 800 506 4800
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
Spain – Tel: 901 11 68 90
FranceChinaCanada
US
Italy MexicoJapan
Brazil
Spain
Germany
Australia
Korea
United States – Tel: 800-227-9770