MNRE: Guide Lines For Energy Efficiency 2009
2 Environmental Design Solutions
A SET OF CLIMATE ZONEWISE ENERGY
EFFICIENCY GUIDELINES FOR COMERCIAL &
RESIDENTIAL BUILDINGS
SummaryIn India, there are several norms, regulations, codes and standards to establish energy efficient
buildings that have been evolved by various ministries and government bodies. The MNRE invited
consultants to bid for an assignment which shall harmonize various energy efficiency and renewable
energy related codes/standards/ norms and guidelines for buildings and larger habitats.
The aim of this study is to propose a set of climatic zone-wise passive architectural guidelines
including other energy efficiency and renewable measures for buildings both in residential &
commercial sectors to be followed by CPWD and Municipal Corporations all over the country. The
guidelines are in harmonization with ECBC 2007, NBC 2005, EIA notification 2006, other relevant IScodes.
The guidelines have taken into account the provisions of the National Building Code 2005; the Energy
Conservation Building Code 2007 announced by BEE and other IS codes. The guidelines by its
qualitative and quantitative assessment criteria would be able to ensure an optimized green building
design focusing on passive and other energy efficient techniques. It would be applied to new building
stock of varied functions commercial, institutional, and residential.
MethodologyNOTE - National codes/standards referred for this project are duly referenced. In case of absence of a
local code/standard a relevant international Code/standard is referred. However in absence of both
relevant suggestions are proposed by EDS.
By-laws of different regions/states like Delhi, NCR region, Jaipur etc are being reviewed to
understand their respective structure and indentify possibilities of incorporating changes within
these.
To have better understanding of bye-laws and identify areas of synergies among the codes/ norms
of the respective departments detailed discussion with BEE, BIS (Respective NBC 2005
Committee Members), MoEF, MOUD, GRIHA secretariat are being held.
Relevant national codes/standards like ECBC 2007, NBC 2005, GRIHA and LEED etc are then
referred to develop enforceable strategies and options to be incorporated as minimum standards in
By-Laws. A list of all relevant common and congruous requirements of the codes and normsformulate one document that covers all aspects related to passive design, energy efficiency and
renewable energy of above mentioned documents in logical sequence(under relevant sections
within bye-laws) that will be followed by architects /building designers.
Wherever relevant, a set of practically adoptable recommendations (with detailed specification)
that can be used by an architect to design and implement suitable energy efficiency measures
(emphasizing solar passive architectural techniques) in all climate zones are being recommended.
The guidelines are formulated in a way such that the municipalities and development authorities
should be able to incorporate these guidelines to modify building by laws as required.
8/13/2019 Energy Efficiency Guidelines_darft
3/14
MNRE: Guide Lines For Energy Efficiency 2009
3 Environmental Design Solutions
Future methodology to have further necessary discussions with the officials of MNRE and
GRIHA Secretariat during the time of preparing the documents and will incorporate suggestions
made by them in the documents. Draft guidelines prepared may also be discussed by MNRE with
MoUD and some Municipal Corporations and the suggestions made will be incorporated in the final
document.
RecommendationsBased on the above methodology relevant recommendations are being made emphasizing on solar
passive architectural techniques, energy efficiency along with thermal comfort for commercial and
residential buildings under the following sections:
1. Envelope
2. Heating, Ventilation and Air-conditioning
3. Hot water and Pumping
4. Lighting
5. Passive Design
A document is being formulated to explain all the recommendations under the following categories:
Intentof all the recommendations,
Performance requirementswhich includes detail specifications of types of materials (including
their physical properties like u-factor, r-value etc), efficient equipments (cooling, heating and
lighting), design parameters such as orientation, shading devices, faade glazing ratios, thermal
mass etc. These requirements are to be made mandatory under the respective sections as
specified inIncorporated As and Under Section.
Prescriptive requirements furtherelaborate quantitatively/qualitatively on the recommendations
made under the performance requirements section by specifying the current maximum/minimum
requirements taken from above mentioned codes and standards. In some cases where there are
no existing requirements, relevant suggestions have been made by EDS itself.
Reference standard all theNational codes/standards referred for this project are duly referenced
under this section. In case of absence of a local code/standard a relevant international
Code/standard are referred. However in absence of both relevant suggestions is proposed by
EDS.
Incorporated as and under (Only for Delhi Building Bye-Laws) specifies the relevant section
under which all the respective recommendations are suggested to be made mandatory. However,
further suggestions are required fromBEE, BIS, MoEF, MOUD, GRIHA secretariat for further
clarity on incorporating such under respective categories.
Current requirements specify the existing requirements if any under the bye-laws corresponding
to the respective recommendation.
8/13/2019 Energy Efficiency Guidelines_darft
4/14
BUILDING TYPE - Non Residential
CATEGORY Intent PERFORMANCE REQUIREMENTS PRESCIPTIVE REQUIREMENTS
ENVELOPE Reduceinfiltration
1. Air leakage for glazed swinging entrance doorsand revolving doors shall not exceed 5.0 l/s-m2.
Air leakage for other fenestration and doors shallnot exceed 2.0 l/s-m2.
None
4
Heattransferreductionthroughopaqueenvelope
2. The opaque construction shall comply with themaximum assembly U-factor or the minimuminsulation R-value from ECBC Table - 4.2.
Currently these minimum values are as follows:U-factor R-value
Composite 0.440 2.10 (40mm)Hot and Dry 0.440 2.10 (40mm)Warm and Humid 0.440 2.10 (40mm)Moderate 0.440 2.10 (40mm)
Cold 0.352 2.35 (45mm)
4
Heattransferreductionthrough roof
3. The roof construction shall comply with themaximum assembly U-factor or the minimuminsulation R-value from ECBC Table - 4.1.
Currently these minimum values for day-time use buildingsare as follows:
U-factor R-valueComposite 0.409 2.10 (40mm)Hot and Dry 0.409 2.10 (40mm)Warm and Humid 0.409 2.10 (40mm)Moderate 0.409 2.10 (40mm)Cold 0.409 2.10 (40mm)
4
8/13/2019 Energy Efficiency Guidelines_darft
5/14
8/13/2019 Energy Efficiency Guidelines_darft
6/14
8/13/2019 Energy Efficiency Guidelines_darft
7/14
8/13/2019 Energy Efficiency Guidelines_darft
8/14
MNRE: Guide Lines For Energy Efficiency 2009
8 Environmental Design Solutions
Energy &water usereduction ofswimmingpools
4. Heated pools shall be provided with a vaporretardant pool cover on or at the water surface.Pools heated to more than 32C (90F) shall havea pool cover with a minimum insulation value of R-2.1
PASSIVEDESIGN
AdequateDay-lighting
1. If the effective width of the habitable room ismore than 2 to 2.5 times the distance from the floorto the top of the opening a l ight shelves at aminimum height of 7 feet from the floor level shouldbe provided for deeper penetration of diffuse light..
AdequateDay-lighting
2. For room depth greater than 8 mts openings ontwo opposite sides shall be provided to give greateruniformity of internal daylighting. Both the oppositewalls in these cases shall be adjacent to anexternal space or an internal courtyard/atrium.
AdequateDay-lighting
3. In case of multiple blocks within the samecomplex, the relative availability of daylight inmultistoried blocks of different relative orientationsshould be checked from Table 7 of NBC 2005section 4.2.9.
Minimum
Day-lighting
4. Minimum requirement of 10% openings shall be
met for all habitable rooms having a maximumdepth of 7 mts. Beyond that, the percentage willincrease by 10% for every additional 7mts.
Adequatefresh airsupply
5. Fresh air requirements shall comply with thedesign guidelines provided for ventilation in theNational Building Code of India 2005 Part 8, 5.2.2.1
AdequateDay-lighting
6. Broader openings shall have their cills raised by300 mm to 600 mm above the working plane.
Naturalventilation
7. A minimum 4 percent window to floor area ratioshould be provided as a provision for naturalventilation indoor.
8/13/2019 Energy Efficiency Guidelines_darft
9/14
MNRE: Guide Lines For Energy Efficiency 2009
9 Environmental Design Solutions
BUILDING TYPE - Residential
CATEGORY Inten t PERFORMANCE REQUIREMENTS PRESCIPTIVE REQUIREMENTS
ENVELOPE Reduceinfiltration
1. Air leakage for glazed swinging entrance doorsand revolving doors shall not exceed 5.0 l/sm2.
Air leakage for other fenestration and doors shallnot exceed 2.0 l/s-m2.
None S4
Heat transferreductionthroughopaqueenvelope
2. The opaque construction shall comply with themaximum assembly U-factor or the minimuminsulation R-value from ECBC Table - 4.2.
Wall Assembly U ValueClimate Zone Maximum U-Value of the
overall assembly(W/m2K)Composite 1.1
Hot and Dry 1.1Warm and Humid 1.25Moderate 1.25Cold 0.5
S4
Heat transferreductionthrough roof
3. The roof construction shall comply with themaximum assembly U-factor or the minimuminsulation R-value from ECBC Table - 4.1.
Roof Assembly U ValueClimate Zone Maximum U-Value of the
overall assembly(W/m2K)Composite 0.50Hot and Dry 0.50Warm and Humid 0.50Moderate 0.50Cold 0.50
S4
8/13/2019 Energy Efficiency Guidelines_darft
10/14
8/13/2019 Energy Efficiency Guidelines_darft
11/14
8/13/2019 Energy Efficiency Guidelines_darft
12/14
8/13/2019 Energy Efficiency Guidelines_darft
13/14
MNRE: Guide Lines For Energy Efficiency 2009
13 Environmental Design Solutions
Prevent heatloss
Provide solar water heating system to satisfy hotwater requirement for domestic purposes. Theminimum hot water requirement for domesticpurposes should be calculated for 25 liters perperson per day
S5
Energy &water usemeasurementandverification
Provide meters for any four of the following: Energy meter for air-conditioning Energy meter for internal lighting Energy meter for external lighting Energy meter for municipal water pumping Energy meter for water pumping for landscaping
S
PASSIVEDESIGN
AdequateDay-lighting
1. If the effective width of the habitable room ismore than 2 to 2.5 times the distance from the floorto the top of the opening a light shelves at aminimum height of 7 feet from the floor level shouldbe provided for deeper penetration of diffuse light..
a
AdequateDay-lighting
2. For room depth greater than 8 mts openings ontwo opposite sides shall be provided to give greateruniformity of internal daylighting. Both the oppositewalls in these cases shall be adjacent to an
external space or an internal courtyard/atrium.
AdequateDay-lighting
3. In case of multiple blocks within the samecomplex, the relative availability of daylight inmultistoried blocks of different relative orientationsshould be checked from Table 7 of NBC 2005section 4.2.9.
Minimum Day-lighting
4. Minimum requirement of 10% openings shall bemet for all habitable rooms having a maximumdepth of 7 mts. Beyond that, the percentage willincrease by 10% for every additional 7mts.
Adequatefresh airsupply
5. Fresh air requirements shall comply with thedesign guidelines provided for ventilation in theNational Building Code of India 2005 Part 8, 5.2.2.1 a
8/13/2019 Energy Efficiency Guidelines_darft
14/14
References1. ECBC 2007,
2. NBC 2005,3. EIA notification 2006,
4. other relevant IS codes,
5. GRIHA,
6. LEED India NC Version 1.0
7. LEED India CS Version 1.0
8. IGBC Green Homes,
9. Municipal By-Laws (Delhi, NCR, Jaipur),
10. MNRE (Ministry of New & Renewable Energy) Publications,
11. MoEF (Ministry of Environment & Forest) manual etc.