ENDUR� M -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12) INSTALLATION INSTRUCTIONS MALARKEY PROCESS ENGINEER PLEASE SPECIFY PROVIDED DRIP EDGE (12'-0" LENGTHS) DEFLECTOR (12'-0" LENGTHS TYP. BOTH SIDES ONLY REQUIRED IF PITCH IS LESS THAN 4/12) INTERMITTENT SPACER 12" O.C. 3½" WIDE DEFLECTOR BAFFLE AT DEFLECTOR JOINTS ÊUON! INSLLERS SHALL R PROCTIVE E R PRENT INJURY. DO NOT OVERDRIVE úSNERS, AS SIPPING CAN OCCUR AT HIGH DRIVER RQUE RECOMMENDED DRING OL: 600 - 800 rpm 2" OPENING FOR 24 NFA 3" OPENING FOR 36 NFA ("X" DIMENSION) U.S. PATENT# 8,978,323 B1 ACCOMMODATES 6 ° 'TO¾" THICK PLYWOOD OR OSB (BY OTHERS) FOR APPLICATION OF ROOFING MATERIALS (BY OTHERS) .050EXPANDED METAL SUPPORT SCREEN CONTINUOUS 20GA.GALV. Z BRACKET ALL FASTENERS BY OTHERS ELECTRIC DRILL EQUIPPED WITH DEP-SENSING NOSE- PIECE PRENT DRIVING AND SIPOUT DO NOT USE IMCT TYPE OL. IMPORTANT! BE SURE TO REMOVE PROTECTIVE PLASTIC FILM PRIOR TO INSTALLING EACH COVER SECTION. NOTE: ALL FASTENERS MUST MEET MINIMUM 240 LB. PULL-OUT FOR SUBSTRATE. EXAMPLE WITH GABLE ENDS (TOP VIEW) 1. PREPARE RIDGE EXAMPLE WITH HIPPED ENDS (TOP VIEW) 6" CUT OPENING AT RIDGE "X" DIMENSION. END THE OPENING 6 " BEFORE GABLE OR HIPPED END. DATE: 05/17/19 SHT.#_ 1 _ OF PHONE: 800-558-2162 ORN BY: JJC C_K_D_B_Y_:_JA-I DWG# 47124-29051 B #10 x 1" SELF DRILLING PANCAKE HEAD SCREWS #10 x 1-1/2" STAINLESS STEEL FASTENERS

ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDUR�

M

-VENT RIDGE VENT

SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

INSTALLATION INSTRUCTIONS

MALARKEY PROCESS ENGINEER

PLEASE SPECIFY

PROVIDED DRIP EDGE (12'-0" LENGTHS)

DEFLECTOR (12'-0" LENGTHS TYP. BOTH SIDES ONLY REQUIRED IF PITCH IS LESS

THAN 4/12)

INTERMITTENT SPACER 12" O.C.

3½" WIDE DEFLECTOR BAFFLE AT DEFLECTOR JOINTS

CAUTION! INSTALLERS SHALL WEAR PROTECTIVE EYE WEAR TO PREVENT INJURY. DO NOT OVERDRIVE FASTENERS, AS STRIPPING CAN OCCUR AT HIGH DRIVER TORQUE. RECOMMENDED DRIVING TOOL: 600 - 800 rpm

2" OPENING FOR 24 NFA

3" OPENING FOR 36 NFA

("X" DIMENSION)

U.S. PATENT# 8,978,323 B1 ACCOMMODATES 1/, 6° ' TO¾" THICK PLYWOOD OR OSB (BY OTHERS) FOR APPLICATION OF ROOFING MATERIALS (BY OTHERS)

.050 EXPANDED METAL SUPPORT SCREEN

CONTINUOUS 20GA.GALV. Z BRACKET

ALL FASTENERS BY OTHERS

ELECTRIC DRILL EQUIPPED WITH DEPTH-SENSING NOSE­PIECE TO PREVENT DRIVING AND STRIPOUT. DO NOT USE IMPACT TYPE TOOL.

IMPORTANT! BE SURE TO REMOVE PROTECTIVE PLASTIC FILM PRIOR TO INSTALLING EACH COVER SECTION.

NOTE: ALL FASTENERS MUST MEET MINIMUM 240 LB. PULL-OUT FOR SUBSTRATE.

EXAMPLE WITH GABLE ENDS (TOP VIEW)

1. PREPARE RIDGE

EXAMPLE WITH HIPPED ENDS (TOP VIEW)

6"

CUT OPENING AT RIDGE "X" DIMENSION. END THE OPENING 6" BEFORE GABLE OR HIPPED END.

DATE: 05/17 /19 SHT.#_1_ OF _1__ PHONE: 800-558-2162 ORN BY: JJC

1-C_K_D_B_Y_:_JA-I ----IDWG# 47124-29051 B

#10 x 1" SELF DRILLING PANCAKE HEAD SCREWS

#10 x 1-1/2" STAINLESS STEEL FASTENERS

rhayes
Line
rhayes
Line
rhayes
Rectangle
Page 2: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDUR�

M

-VENT RIDGE VENT

SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

INSTALLATION INSTRUCTIONS

2. RIDGE VENT

THE RIDGE VENT IS MANUFACTURED TO BEND TO ACCOMMODATE 3/12 TO 12/12 ROOF PITCHES. SIMPLY SET RIDGE VENT ON ROOF AND BEND SPACERS TO THE CORRECT PITCH.

"Z" BRACKET

� APPLY NON-CURING SEALANT (BY OTHERS) TO BOTTOM OF ENTIRE LENGTH OF "Z" BRACKET

3. "Z" BRACKETS

TO PREVENT MOISTURE ENTRY UNDER THE "Z", APPLY A GENEROUS BEAD OF NON-CURING SEALANT (BY OTHERS) ALONG ENTIRE LENGTH OF BOTTOM OF FLANGE.

INTERMITTENT SPACERS BENT TO ROOF PITCH

APPLY NON-CURING SEALANT (BY OTHERS) TO BOTTOM OF ENTIRE LENGTH OF "Z" BRACKET

DATE: 05/17/19 SHT.#_1__ OF__]_ PHONE: 800-558-2162 DRN BY: JJC

CKD BY: JAi DWG# 47124-29051 B

Page 3: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDUR�

M

-VENT RIDGE VENT

SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

INSTALLATION INSTRUCTIONS

4. RIDGE VENT

SET RIDGE VENT IN PLACE CENTERED OVER RIDGE OPENING. FASTEN BRACKETS AT ROOF AT 6 11 O.C. WITH APPROPRIATE FASTENERS USING PRE-PUNCHED SLOTTED HOLES. LAP "Z'S" 1 ".

INTERMITTENT SPACERS 12" o.c.

5.PLYWOOD

PLACE PLYWOOD ON TOP OF INTERMITTENT SPACER AND FASTEN TO SPACER FLANGE 12" O.C. WITH APPROPRIATE FASTENERS.

/FASTEN PLYWOOD THRU EACH INTERMITTENT SPACER WITH APPROPRIATE FASTENERS

DATE: 05/17 /19 SHT.# _l__ OF _J_ PHONE: 800-558-2162 ORN BY: JJC

CKD BY: JAi DWG# 47124-29051 B

#10 x 1" SELF DRILLING PANCAKE HEAD SCREWS

#10 x 1-1/2" STAINLESS STEEL FASTENERS

Page 4: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDUR�

M

-VENT RIDGE VENT

SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

INSTALLATION INSTRUCTIONS

6.DRIP EDGE

SLIDE DRIP EDGE OVER EXPANDED METAL SUPPORT SCREEN AND PLYWOOD. FASTEN 12" O.C. WITH APPROPRIATE FASTENERS.

7.DRIP EDGE

I

LAP DRIP EDGE 1"�.(_

CONTINUE INSTALLING DRIP EDGE, LAPPING 1" AT JOINTS. NOTE: REMOVE PROTECTIVE FILM IMMEDIATELY.

/

FASTEN THRU PRE-SLOTTED HOLES WITH APPROPRIATE FASTENERS 12" O.C.

DATE: 05/17 /19 SHT.# _!_ OF _J_ PHONE: 800-558-2162 DRN BY: JJC

CKD BY: JAi DWG# 47124-29051 B

#10 x 1" SELF DRILLING PANCAKE HEAD SCREWS

#10 x 1" SELF DRILLING PANCAKE HEAD SCREWS

Page 5: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDURA™

-VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

INSTALLATION INSTRUCTIONS

PART B

8. ENDCAPS

APPLY NON-CURING SEALANT (BY OTHERS)

TO BACKSIDE OF SEAM

BEND TO PROPER \RIDGE PITCH \

' ...

PART B MAY NEED TO BE TRIMMED AT EDGES

\ AFTER ADJUSTING TO PROPER PITCH, FASTEN PARTS TOGETHER AS SHOWN USING APPROPRIATE FASTENERS

FASTEN TOP OF ENDCAP TO PLYWOOD WITH APPROPRIATE

FASTENERS

NON-CURING SEALANT (BY OTHERS) UNDER ROOF FLANGE

FASTEN DRIP EDGE TO ENDCAP

(BOTH SIDES) WITH APPROPRIATE

FASTENERS

FASTEN FLANGE WITH APPROPRIATE FASTENERS

PLACED WHERE CAP SHINGLE WILL CONCEAL THEM

FABRICATE TWO PART ENDCAP AS SHOWN ABOVE. APPLY GENEROUS AMOUNT OF NON-CURING SEALANT (BY OTHERS) TO RIDGE WHERE THE BOTTOM ENDCAP FLANGE WILL SIT. SLIDE ENDCAP BETWEEN PLYWOOD AND DRIP EDGE. REMOVE PROTECTIVE FILM IMMEDIATELY. USING APPROPRIATE FASTENERS, FASTEN BOTH SIDES OF DRIP EDGE TO ENDCAP. FASTEN TOP FLANGE OF ENDCAP TO PLYWOOD AS SHOWN WITH APPROPRIATE FASTENERS. PLACE TWO FASTENERS (BY OTHERS) ON EACH SIDE OF ROOF FLANGE. PLACE THEM CLOSE ENOUGH TO THE RIDGE SO THE CAP SHINGLE WILL CONCEAL THEM. FOLLOW GENERAL RECOMMENDATIONS OF ROOF MEMBRANE MANUFACTURERS APPLICATION FOR STRIPPING IN THE ENDCAP ROOF FLANGE.

DATE: 05/17 /19 SHT.#� OF __J_ PHONE: 800-558-2162 DRN BY: JJC

CKD BY: JAi DWG# 47124-29051 B

(GALV. ZIP SCREWS)

#10 x 1" SELF DRILLING PANCAKE HEAD SCREWS

#10 x 1" SELF DRILLING PANCAKE HEAD SCREWS

(GALV. ZIP SCREWS)

Page 6: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDURft:

M

-VENT RIDGE VENT

SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

INSTALLATION INSTRUCTIONS

100% SILICONE SEALANT (BY OTHERS)

DEFLECTOR (12'-0" LENGTHS) TYPICAL BOTH SIDES

9. DEFLECTOR

PLACE 100% SILICONE SEALANT AT SLOTTED FASTENING HOLES (NOT SHOWN FOR CLARITY)

APPLY 100% SILICONE SEALANT TO DEFLECTOR AS SHOWN ABOVE. START INSTALLING DEFLECTOR AT ENDCAPS. DETERMINE LOCATION BY REFERRING TO DIMENSION GIVEN ON PAGE 1 PLUS INSTRUCTIONS PROVIDED IN APPENDIX "A" ONLINE AT WWW.MALARKEYROOFING.COM. FASTEN 12" O.C. THRU PRE-SLOTTED HOLES WITH APPROPRIATEFASTENERS. CONTINUE INSTALLING, LAPPING 1" AT JOINTSAS SHOWN. LAPPING LEAVES A 1" GAP BETWEEN PIECES.FIELD CUT WHERE NECESSARY USING FINE TOOTHHACKSAW OR SNIPS.

DEFLECTOR

SEE PAGE 1

Tl

FOR DIMENSION �

FASTEN THRU PRE-SLOTTED HOLES 12" O.C. WITH APPROPRIATE FASTENERS

DATE: 05/17 /19 SHT.# _§_ OF _J_ PHONE: 800-558-2162 ORN BY: JJC

CKD BY: JAi DWG# 47124-29051 B

#10 x 1-1/2" STAINLESS STEEL FASTENERS

Page 7: ENDUR -VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ... · if pitch is less than 4/12) intermittent spacer 12" o.c. 3½" wide deflector baffle at deflector joints caution! installers

ENDURA™

-VENT RIDGE VENT SLOPE TO SLOPE, SHINGLED, FIELD ROOFED VERSION WITH DEFLECTORS (ROOF PITCHES 3/12 TO 12/12)

DEFLECTOR BAFFLE 3½"WIDE

FASTEN ONE SIDE WITH APPROPRIATE FASTENERS

10. DEFLECTOR BAFFLE

PLACE 3½" WIDE DEFLECTOR BAFFLE AT ALL DEFLECTOR JOINTS. FASTEN ONE SIDE OF BAFFLE THRU DEFLECTOR INTO EXISTING ROOF WITH APPROPRIATE FASTENER.

DEFLECTOR BAFFLE 3½"WIDE

DATE: 05/17 /19 SHT.#_L_ OF _L_ PHONE: 800-558-2162 DRN BY: JJC

CKD BY: JAi DWG# 47124-29051 B

#10 x 1-1/2" STAINLESS STEEL FASTENERS