32
EndoVue® USER MANUAL ENGLISH

EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

  • Upload
    lamphuc

  • View
    219

  • Download
    1

Embed Size (px)

Citation preview

Page 1: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

EndoVue®

USER MANUALENGLISH

Page 2: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1
Page 3: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

© 2016 NDS Surgical Imaging, LLC. All rights reserved.

Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. NDSsi provides this information as reference only. Reference to products from other vendors does not imply any recommendation or endorsement.

This document contains proprietary information protected by copyright. No part of this manual may be reproduced by any mechanical, electronic, or other means, in any form, without prior written permission of NDSsi.

All trademarks are the property of their respective owners

Page 4: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1
Page 5: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Table of ContentsSafety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii

Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iiiPower Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv

Power Cord. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ivGrounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv

Intended Use and Contraindications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ivSafety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vImage Retention Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vRecycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

Terms and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viDeclarations of Conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viLegal Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .viStandard Warranty and Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii

VESA Compliant Display Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Monitor Stand Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Enclosure Assembly and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Cable Cover Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General maintenance information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Display User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Display Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

INPUT and MENU Buttons: Open OSD Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3SCROLL Button: Vertical Selection Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Left/Right Buttons: Horizontal Selection Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Input Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Display Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Picture Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Color Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Defaults Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Image Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Connector Panel Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

EndoVue Connector Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Connector Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Data Connectors and Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7DVI-I Digital and Analog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7VGA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8S-Video. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Composite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Firmware Connector and Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Mini USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Power Connector and Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 924 VDC Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Electrical Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Optional 5 VDC Fiber Power Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Cable Bend Radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Supported Resolutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

DVI Supported Resolutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11VGA, RGBS, and YPbPr Supported Resolutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

EndoVue Parts List by Region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Table of Contents | i

Page 6: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Electromagnetic Compatibility Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Electromagnetic Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Electromagnetic Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Recommended Separation Distances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

ii | Table of Contents

Page 7: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Safety Information

Warnings and CautionsThis symbol alerts the user that important information regarding the installation and/or operation ofthis equipment follows. Information preceded by this symbol should be read carefully in order to avoiddamaging the equipment.This symbol warns the user that un-insulated voltage within the unit may have sufficient magnitude tocause electrical shock. It is dangerous to make contact with any part inside the unit. To reduce the risk ofelectric shock, DO NOT remove cover (or back).NOTE: There are no user serviceable parts inside. Refer servicing to qualified service personnel.This symbol cautions the user that important information regarding the operation and / or maintenanceof this equipment has been included. Information preceded by this symbol should be read carefully toavoid damage to the equipment.This symbol denotes the manufacturer.

This symbol denotes the manufacturer’s European Community representative.EndoVue series monitors are designed to display high quality video and graphic images for use in a medicalenvironment. They are designed to accept all standard video and graphic signals, and most special timings frommedical equipment. Built-in video controllers convert and format incoming signals of various signal types tomatch the resolution of the LCD panel. The user can make adjustments to video parameters using the frontkeypad of the monitor with the On Screen Display (OSD) interface to optimize the viewing experience fordifferent applications.To prevent fire or shock hazards, do not expose this unit to rain or moisture. Also, do not use this unit's polarizedplug with an extension cord receptacle or other outlets unless the prongs can be fully inserted. The product isdesigned to meet the medical safety requirements for a patient vicinity device.

Warning: To avoid risk of electric shock, this equipment must be only connected to a supply mains withprotective earth.

The installation shall only be carried out by NDS authorized and trained personnel.This device is only intended to be used in professional healthcare environment.This equipment/system is intended for use by healthcare professionals only.This product is a Class I medical device. No modifications are allowed.Monitors are intended for continuous operation.

Safety ComplianceThis product is T.U.V. approved with respect to electric shock, fire and mechanical hazards only inaccordance with CAN/CSA C22.2 No. 60601-1 and ANSI/AAMI ES60601-1.Safety ComplianceThis device meets the requirements of EN60601-1 so as to conform to the Medical Device Directive 93/42/EEC and 2007/47/EC (general safety information).Safety and EMI ComplianceGB9254, GB4943.1 and GB17625.1S&E

Safety Information | iii

Page 8: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Power SupplyFor Customers in North AmericaEndoVue series monitors comply to the above standards only when used with the supplied hospital grade powersupply. Note: This power supply is a part of the medical device.

For Customers in ChinaThis power supply is to be used with this monitor.

Power CordFor Customers in North AmericaUse a hospital grade power cord with the correct plug for your power source.The power cord is the only recognized disconnect device. Disconnect the power cord from the AC mains.MEDICAL EQUIPMENT should be positioned so that the disconnect device is readily accessible.Monitors should be powered from a center tapped circuit when used in the US at voltages over 120 volts.For Customers in ChinaUse China Compulsory Certificate (CCC)-approved power cord.For Customers in JapanThe supplied power cord is for use only with this monitor.

GroundingThis product is energized from an external electrical power source for Class 1 equipment. It is the responsibility ofthe installer to test the product’s earth ground to verify that it complies with the hospital, local and nationalimpedance requirements.A ground post is located on the back of the product to use for grounding the chassis of the unit. Any such groundmust be installed in accordance with applicable electrical codes. The ground post location is shown in theEndoVue Connector Panel diagram on page 7.Grounding reliability can only be achieved when the equipment is connected to an equivalent receptaclemarked “Hospital Only” or “Hospital Grade.”

Intended Use and ContraindicationsIntended UseEndoVue series monitors are intended for use in a medical environment to display high quality video and graphicimages.Contraindications1. Do not use this product in the presence of flammable anesthetics mixture with air, oxygen or nitrous oxide.2. No part of this product may come in contact with a patient. Never touch the product and a patient at the

same time.3. This product is capable of displaying Radiology (PACS) images for reference, not diagnostic, purposes only.4. For mission critical applications, we strongly recommend that a replacement unit be immediately available.

Model BridgePower BM060S24FAC Input 100 - 240 Volts, 50 to 60 Hz

DC Output 24 Volts, 2.7 Amps

Model BridgePower BM060S24FAC Input 100 - 240 Volts, 50 to 60 Hz

DC Output 24 Volts, 2.7 Amps

iv | Safety Information

Page 9: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Safety PrecautionsExternal equipment intended for connection to signal input/output or other connectors shall meet the level ofsafety equivalent to ME equipment complying with the relevant standard. In addition, all such combinations-systems shall comply with the standard. Equipment not complying with UL/EN/IEC 60601-1 shall be kept outsidethe patient environment, as defined in the standard. Any person who connects external equipment to the signalinput, signal output, or other connectors has formed a system and is therefore responsible for the system tocomply with the requirements of IEC or ISO safety standards. If in doubt, speak with a qualified technician.If such equipment and other medical devices are connected to form a medical electrical system(s), a green lightindicator shall be provided on the final ME system(s) to indicate that this equipment is ready for normal use.

Image Retention NoticeWarning: Leaving a fixed (constant) image on the monitor for a long period of time can result in imageretention. Avoid leaving a fixed image on the monitor, or turn the monitor off when it is not in use.

RecyclingFollow local governing ordinances and recycling plans regarding the recycling or disposal of thisequipment.

Safety Information | v

Page 10: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Terms and Conditions

Declarations of ConformityFCC and Council Directives of European StandardsThis device complies with Part 15 of FCC rules and 93/42/EEC and 2007/47/EC of the Council Directives ofEuropean Standards. Operation is subject to the following two conditions: (1) This device may not cause harmfulinterference, and (2) this device must accept any interference received, including interference that may causeundesirable results.1. Use the attached specified cables with the color monitor so as not to interfere with radio and television recep-

tion. Use of other cable and adapters may cause interference with other electronic equipment.2. This equipment has been tested and found to comply with the limits pursuant to FCC part 15 and CISPR 11.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radio communications.

IECThis equipment has been tested and found to comply with the limits for medical devices to the IEC 60601-1-2.These limits are designed to provide reasonable protection against harmful interference in a typical medicalinstallation. This equipment generates, uses and can radiate radio frequency energy and, if not installed andused in accordance with the instructions, may cause harmful interference to other devices in the vicinity.FCC, Council Directives of European Standards, and IEC:There is no guarantee that interference will not occur in a particular installation. If this equipment does causeharmful interference to radio or television reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult your dealer or an experienced radio/TV technician for help.

Accessory equipment connected to this product must be certified according to the respective IEC Standards (i.e.,IEC 60950-1) for data processing equipment and IEC 60601-1 for medical equipment. Furthermore, allconfigurations shall comply with the system standard, IEC 60601-1-1. Anyone who connects additionalequipment to the signal input part or signal output part configures a medical system, and is thereforeresponsible that the system complies with the requirements of system standard IEC 60601-1-1. Whoever isresponsible for securing the unit to a system needs to insure that the mounting equipment used with thisproduct complies to IEC standard 60601-1. If in doubt, consult the technical services department or your localrepresentative.

Legal StatementNDS may sell its products through other medical device manufacturers, distributors and resellers and therefore,purchasers of this NDS product should consult with the entity through which this product was originallypurchased regarding the terms of any applicable product warranties provided by such entity, if any.NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and/orrelated to the sale and/or use of its products. To ensure proper use, handling and care of NDS products,customers should consult the product specific literature, instruction manual, and/or labeling included with theproduct or otherwise available.Customers are cautioned that system configuration, software, the application, customer data and operatorcontrol of the system, among other factors, affect the product’s performance. While NDS products are consideredto be compatible with many systems, specific functional implementation by customers may vary. Therefore,suitability of a product for a specific purpose or application must be determined by the customer and is notwarranted by NDS.NDS SPECIFICALLY DISCLAIMS ALL WARRANTIES OF ANY KIND, WHETHER EXPRESS, IMPLIED AND/ORSTATUTORY, INCLUDING, BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, FITNESS AND/OR OFSUITABILITY FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT WITH RESPECT TO ALL NDS PRODUCTS ORSERVICES. ANY AND ALL OTHER WARRANTIES, REPRESENTATIONS AND/OR GUARANTEES, OF ANY TYPE, NATUREOR EXTENT, BE IT IMPLIED, EXPRESS AND/OR WHETHER ARISING UNDER OR AS A RESULT OF ANY STATUTE, LAW,COMMERCIAL USAGE, CUSTOM, TRADE OR OTHERWISE, ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED.

vi | Terms and Conditions

Page 11: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

NDS, its suppliers and/or distributors are not liable, directly or by way of indemnity for any special, incidental,consequential, punitive, exemplary or indirect damages, including but not limited to alleged damages fordelayed shipment, non-delivery, product failure, product design or production, inability to use such products orservices, loss of future business (lost profits), or from any other cause, whatsoever, in connection with or arisingfrom the purchase, sale, lease, rental, installation or use of such NDS products, these terms and conditions, orwith respect to any the terms of any agreement which incorporates these terms and conditions.SOME JURISDICTIONS DO NOT ALLOW EXCLUSIONS AND DISCLAIMERS OF CERTAIN WARRANTIES ORLIMITATIONS OF LIABILITY, SO THE LIMITATIONS AND/OR EXCLUSIONS, SET FORTH HEREIN, MAY NOT APPLY. INTHAT EVENT LIABILITY WILL BE LIMITED TO THE GREATEST EXTENT PERMITTED BY LAW IN THE SUBJECTJURISDICTION.The information provided in this document, including all designs and related materials, is the valuable propertyof NDS and/or its licensors and, as appropriate, they reserve all patent, copyright, and other proprietary rights tothis document, including all design, manufacturing reproduction, use, and sales rights thereto, except to theextent said rights are expressly granted to others.

Standard Warranty and ServiceCOVERAGE: NDS warrants this product to be in compliance with the specifications provided by NDS and to befree from defects in material and workmanship as defined in such specifications. Subject to the conditions setforth below, NDS agrees to repair or replace any part of the enclosed unit for the length of period indicated onthe chart below:

WARRANTY SERVICE - REPAIR & RETURN1. Our standard warranty service is “Repair and Return.” Repair and Return requires the defective unit to be

returned to our service location for repair.2. Cost of shipment of the defective unit to NDS is the responsibility of the customer. Cost of shipment of the

repaired unit to Customer is the responsibility of NDS.3. NDS reserves the right in its sole discretion to provide Customer with a comparable refurbished replacement

unit in lieu of repair of customer's defective unit.4. If NDS is unable within a reasonable time to repair or replace the defective unit, it shall refund the purchase

price for the product paid by the customer (exclusive of taxes, installation and shipping related fees).

EXCLUSIONS - WHAT IS NOT COVERED1. Any product with a defaced, modified, or removed serial number.2. Damage, deterioration or a malfunction resulting from accident, misuse, neglect, fire, water, lightning, or

other acts of nature, unauthorized product modification, or failure to follow instructions supplied with theproduct.

3. Cosmetic damage including, but not limited to: scratches, cracks, dents, markings, glue and adhesive residue.4. Any damage of the product due to shipment.5. Any damage caused by factors external to the product, such as electric power fluctuation or failure.6. Normal wear and tear.7. Removal, installation, and set-up service charges.8. Failures not reported within the warranty term.9. Any NDS products purchased through a distributor, reseller, or medical device manufacturer other than NDS

(each, an “Intermediary”), where such Intermediary provides direct warranty service to its end-user customersin connection with such product.a. An Intermediary may provide their end-user customers direct warranty support. Please contact NDS

Customer Service to determine if the product that you purchased is covered by this Standard LimitedWarranty or whether you need to contact the Intermediary through which you purchased the product forwarranty service.

NDS Product Standard Warranty Coverage

EndoVue Series 19", 21", 24" and 32" 1 Year from date of shipment by NDS

Terms and Conditions | vii

Page 12: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

CONTACTING NDS CUSTOMER SERVICE

1. Contact NDS Customer Service during the hours listed above. Have your NDS model number and serialnumber available. You may be required to provide proof of purchase as a condition for receiving warrantyservice.

2. Our representative may perform troubleshooting and diagnosis of the problem over the telephone/email. Ifour representative is unable to fix the problem over the phone/email, we will issue a Return MaterialAuthorization (RMA) for the non-functioning unit and provide return instructions.

3. Upon receipt of the returned product, a service technician will evaluate the unit and confirm the failuredescription provided by the customer.a. If the found failure type is covered under warranty, the repair, parts, labor and shipment back to the

customer will be at no charge.b. If the found failure type is not covered under warranty, NDS’s then current evaluation fee will apply in

addition to the cost of parts, labor and the return shipment.c. If the unit is within the warranty period but the customer does not provide a problem description and the

service technician cannot determine the failure (no problem found - “NPF”) NDS’s then current evaluationfee will apply in addition to return shipment.

Payment for Non-Warranty Evaluations and Repairs and other Evaluation Charges: Non-warranty repairsrequested by the customer will be performed at NDS's then current rates for any non-warranty repairs and willinclude applicable evaluation fees and the cost of return shipping (if customer requests that NDS ship therepaired product). NDS further reserves the right, in its sole discretion, to request pre-payment for any non-warranty repairs, NPF evaluations, and return shipping charges prior to return of the product to customer. Anyinvoiced amount not paid when due shall be subject to a service charge equal to the lesser of one and one-halfpercent (1.5%) per month or the maximum rate permitted by law. If NDS undertakes collection or enforcementefforts, customer shall be liable for all costs thereof, including attorney's fees. NDS reserves the right to suspendwarranty coverage to any customer who is in default of payment until such payment has been made.

DISCLAIMERThis limited product warranty sets forth your sole and exclusive remedy and NDS's sole and exclusive liabilityunder the Standard Limited Warranty described herein.There are no warranties, express or implied, which extend beyond the description contained herein including,but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or non-infringement.NDS's liability is limited to the cost of repair or replacement of the product. NDS shall not be liable for:1. Damage to other property caused by any defects in the product, damages based upon inconvenience, loss of

use of the product, loss of time, loss of profits, loss of business opportunity, loss of goodwill, interference withbusiness relationships, or other commercial loss, even if advised of the possibility of such damages.

2. Any other damages, whether incidental, indirect, consequential or otherwise.3. Any claim against the customer by a third party.End-users are cautioned that system configuration, software, the application, customer data and operatorcontrol of the system, among other factors, affect the product performance. While NDS products are consideredto be compatible with many systems, specific functional implementation by the customers of the product mayvary. Therefore, suitability of a product for a specific purpose or application must be determined by consumerand is not warranted by NDS.This warranty gives you specific legal rights. You may have other rights, which may vary from locality to locality.Some localities do not allow limitations on implied warranties and/or do not allow the exclusion of incidental orconsequential damages, so the above limitations might not apply to you.

Country Phone Email Time AvailableUnited States + 408-754-4210 [email protected] 7am to 5pm PST

Europe +420 530 511 900 [email protected] 7am to 5pm CET

China +86 10 8559 7856 [email protected] 9am to 5pm

Japan + 81-3-5753-2466 [email protected] 9am to 5:30pm

viii | Terms and Conditions

Page 13: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

VESA Compliant Display MountingEndoVue series displays are compliant with the VESA Mounting Interface Standard, with MIS hole mountpatterns configured to size and weight of the display, suitable for stand, wall, or armature mounting. MIS-D 100 x100 mm and MIS-E 200 x 100 mm interfaces are shown below.

Monitor Stand InstallationTo install the EndoVue monitor stand (optional for 19", 21", and 24" monitors), place the monitor screen-down ona clean, flat surface and position the four mounting screw holes of the stand mounting bracket over the four-hole attachment interface on the monitor back.Insert one of the four provided cap screws into a screw hole and lightly tighten. Repeat the process with theremaining screws, and then check to confirm that the mounting bracket is flat against the back surface of themonitor before tightening all screws securely.Note: Mounting bracket of the stand can be tilted up to 30°.

Warning: The mounting bracket screws must be securely tightened. Failure to properly secure themounting bracket to the display could be hazardous. Use suitable mounting apparatus to avoid risk ofinjury.

100 mm

200 mm

100 mm

M4 X 0.7Thread

(4x) M4 X 0.7Thread

(4x)

MountingBracket

M4 Cap Screw (4x)

VESA Compliant Display Mounting | 1

Page 14: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Enclosure Assembly and CleaningCable Cover Installation1. Connect power, control, and video cables before installing the cable cover.2. Align the cable cover to the cable well recess on the back of the display.3. Slide the cable cover forward into the recess, with cables positioned under the cut-out.4. Slide the cable cover forward until tabs on the bottom edge click into place.

Cleaning InstructionsGeneral maintenance informationEndoVue series monitors do not require any scheduled maintenance or calibration activities. If any abnormalsituation found, please return the display to our approved maintenance organization. For any questions, pleasecall Customer Service for assistance at (877) 637-1110.

Warning: Prior to cleaning, the display should be turned OFF and disconnected from the power source.• Do not allow liquids to enter the interior of the unit, as severe damage to the unit can result.• Do not use solvents such as benzene or thinner, or any acid, alkaline or abrasive detergents.

Front Glass: Thoroughly wipe the front glass surface with a lint-free cloth. For persistent spots or smudges, use alint-free cloth dampened with distilled water. Do not use any harsh solvents, abrasive detergents or chemicalcleaning cloths.Plastic Enclosure: Wipe all exterior surfaces with a lint-free cloth dampened with distilled water or a mild glasscleaner such as 70% isopropyl alcohol, Vinegar (distilled white vinegar, 5% acidity). If a mild glass cleaner is used,remove any residual cleaning material by wiping all exterior surfaces with a lint-free cloth dampened withdistilled water afterwards. Note: Do not use the following products:• MEK (Methyl Ethyl Ketone)• Toluene• Acetone• Benzene or thinner• Acid• Alkaline or abrasive detergents• Chemical Cleaning cloths

2 | Enclosure Assembly and Cleaning

Page 15: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Display User Interface

Display KeypadThe Display Keypad is centered on the lower front surface of the display enclosure, providing controls foradjustment of display parameters using the On Screen Display (OSD) Menu system.

Menu NavigationINPUT and MENU Buttons: Open OSD Menus

To open the Input Menu, press the INPUT button. To open the Display Menu, press the MENU button.

SCROLL Button: Vertical Selection ControlTo enter a menu and begin a parameter selection process, press the SCROLL button. The top parameterrow is first selected, and the selection moves downward to the next row with each successive press of thebutton.To exit a menu, use the SCROLL button to move the selection to the bottom menu row, and then press the

SCROLL button just once to highlight the menu tab, where you can use the or buttons to select anothermenu tab.

Left/Right Buttons: Horizontal Selection ControlsTo adjust a parameter, select the parameter row using the SCROLL button, then press the or buttons to make the adjustment or to select a setting.

Input MenuTo select or change an input source, press the INPUT button to access the Input Menu. press the SCROLLbutton to highlight the desired input and press the button to select it. A √ symbol in the left columndesignates the active input.

The Input Menu automatically closes 30 seconds after the last action. It can also be closed by pressing the INPUTbutton.

INPUT MENU SCROLL

INPUT MENU

SCROLL

INPUT

Display User Interface | 3

Page 16: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Display MenuTo open the Display Menu, press the MENU button. The Picture Menu displays by default, with details ofthe current video input listed across the top of the menu above the menu tabs.To select other menus, press the or buttons to highlight the menu tab, then press the SCROLLbutton to enter the menu.

To adjust a parameter, press the SCROLL button to move the row selection down to it, and then press the or buttons to adjust the parameter or to select a setting. Parameter adjustments are applied in real time whilechanging values or settings.The Display Menu automatically closes 30 seconds after the last action. It can also be closed by pressing theMENU button.Note: Grayed out descriptions indicate parameters not available for the current signal or input configuration.

Picture MenuNote: Picture Menu display only thoseparameters that apply to specific inputsignals.Horizontal Position (All except DVI-D)

To horizontally center the image, press the or buttons.

Vertical Position (All except DVI-D)To vertically center the image, press the or buttons.

SharpnessTo adjust sharpness (edge enhancement) ofthe displayed image, press the or buttons.

Phase (VGA/RGBS, YPbPr only)To adjust phase of the display pixel clock, press the or buttons.

Frequency (VGA/RGBS, YPbPr only)To adjust frequency of the display pixel clock until the image fills the screen horizontally, first set Scaling to Fill,and press the or buttons.

Overscan (Video)Parameter enabled when the input is 16:9, 480P, 576P, or interlaced. Press the or buttons to select.0: The image is displayed at a size that fills the screen without losing any video information. Image could bedisplayed as letterboxed, with black bars top and bottom or left and right.1, 2, 3, 4, 5 or 6: Incrementally enlarges and crops the centered image. As the image becomes larger, videoinformation is lost on all sides.

Scaling (Graphics)Parameter enabled when input signal is not 16:9, 480P, 576P, or interlaced. Press the or buttons to select.Fill: Expands the video image to fill the entire screen. The aspect ratio may not be accurately displayed.Aspect: Expands the video image until its largest dimension fills the screen while retaining the aspect ratio.The image may be displayed as letterboxed, with black bars top and bottom or left and right.1:1: Displays the video data in its native size and aspect ratio. Image with aspect ratios different from that ofthe display are letterboxed, with black bars top and bottom or left and right.

SmartSync™/Alternative Modes (VGA/RGBS, YPbPr only)NDS proprietary SmartSync technology examines incoming signals to automatically display the video imagein its proper format.Alternative Modes are used to manually distinguish between modes whose timing characteristics are veryclose.SmartSync: To enable SmartSync, press the button.Alternative Modes: To make an Alternative Modes adjustment, press the button. After selecting AlternativeModes. the mode changes incrementally each time the button is pressed until the selected mode equalsthe maximum available. The next press of the button restores the initial mode.

MENU

4 | Display User Interface

Page 17: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Video Format (Composite, SDI, S-Video only)Auto: Examines incoming signals to automatically display the video image in NTSC or PAL format.NTSC/PAL: Press the or buttons to manually select.

Color MenuGamma

To select a gamma setting, press the or buttons..

1.8, 2.0, 2.2, 2.4 or 2.6: Preset gammavaluesVideo: Linear gamma Look Up Table (LUT)PACS: DICOM gamma LUTThis product is capable of displayingRadiology (PACS) images for referencepurposes only.

Color TemperatureTo select a preset color temperature, pressthe or buttons.5500, 6500, 8000, 9300: Preset color temperatures.User: If a preset color temperature is selected, and any other parameter is subsequently changed, the resultingvalues are copied to the Color Correction User presets and User is selected

Red, Green, BlueTo increase or decrease the intensity of the selected color, press the or buttons.

SaturationTo set the saturation (color intensity) of the image, press the or buttons.

HueTo set the hue (color tint) of the image, press the or buttons.

Setup MenuMenu Position:

To select from nine preset screenlocations for display of the OSD menus,press the or buttons.

Language:To select one of 18 languages: Chinese,Danish, Dutch, English, Finnish, French,German, Greek, Italian, Japanese,Korean, Norwegian, Polish, Portuguese,Russian, Spanish, Swedish, and Turkish,press the or buttons.

DPMS EnableTo enable or disable Display Power Management System (DPMS), press the or buttons.Off: Default setting.On: If there is no input signal, a “D.P.M.S” message displays for 10 - 15 seconds before the display goes intoPower Saving mode. The display turns on when the input signal is restored.

Auto Source SelectTo disable or enable Auto Source Select, press the or buttons.Off: Video input is manually selected.On: Searches through all possible input sources until an active video source is found.

Menu LockTo enable Menu Lock, press the button.Off: Default setting.On: Disables access to OSD menus to prevent inadvertent changes to display settings. The OSD closes, and aMENU LOCKED message displays briefly. To unlock OSD access, simultaneously press and hold the MENU andSCROLL buttons until a MENU UNLOCKED message displays.

Display User Interface | 5

Page 18: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Operating HoursDisplays in hours and minutes the accumulated time the monitor has been in use.

FWVersion number of the display firmware.

Defaults MenuFactory Defaults

To return all changed parameter settings to factory preset values, press the button. The “Restoring Factory Defaults” message displays while processing.

User DefaultsTo save changes to default parameters ina User Default profile, press the SCROLLbutton to select a User Defaults profile marked ***EMPTY*** and press the button to save the profile. The“Saving User Defaults” message displays while processing.

To restore a User Defaults profile after changing other parameters, select the saved User Defaults profile andpress the button. The “Restoring User Profile” message displays while processing. To clear a User Defaultsprofile, select the saved User Defaults profile and press the (Brightness/Contrast) button. The “Clearing UserProfile” message displays while processing.

Image AdjustmentBrightness/Contrast ButtonPress the (Brightness/Contrast) button once to access the Brightness control. Press the button twice toaccess the Contrast control, or press it three times to access the Backlight control. Press the or buttons to adjust the controls.

Brightness ControlTo adjust brightness of the designated input, press the or buttons.NOTE: Setting brightness too high or too low reduces the range of shadowand highlight detail of the displayed image.

Contrast ControlTo adjust contrast of the designated input, press the or buttons.Note: Setting contrast too high or too low reduces the range of shadow andhighlight detail of the displayed image, with a negative effect on colorsaturation.

Backlight ControlTo adjust the backlight level of your monitor, press the or buttons.Note: Lower backlight levels increase backlight lifetime.

6 | Display User Interface

Page 19: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Connector Panel OverviewEndoVue Connector Panel

Connector Types

Data Connectors and Pinouts

DVI-I Digital and AnalogDVI-I IN Supports digital and analog (RGBS / YPbPr) signals. Analog data appears on pin 8, and pins C1 - C5.

Notes1. DVI-I/RGBS connector accepts DVI, RGBS or YPbPr signals.2. DVI RE-DRIVE provides Digital output.3. SDI connector is a future option.4. 5VDC / 1A connector provides 5 VDC / 1A output.5. USB connector is used only for installing firmware upgrades.6. VGA/RGBS connector accepts RGBS, YPbPr or VGA signals.

Inputs Connector Types

DVI / RGBS / YPbPr DVI-I, Digital 100 Ohm differential, Analog 75 Ohm terminatedVGA / RGBS / YPbPr HD-15, 75 Ohm terminatedComposite BNC, 75 Ohm terminatedS-Video DIN-4, 75 Ohm terminated

Pin Signal Pin Signal Pin Signal

1 T.M.D.S. DATA 2- 11 T.M.D.S. DATA 1/3 SHIELD 21 N/C

2 T.M.D.S. DATA 2+ 12 N/C 22 T.M.D.S. CLOCK SHIELD

3 T.M.D.S. DATA 2/4 SHIELD 13 N/C 23 T.M.D.S. CLOCK+

4 N/C 14 +5V POWER 24 T.M.D.S. CLOCK-

5 N/C 15 GND DVI-I IN Only

6 DDC CLOCK 16 HOT PLUG DETECT C1 ANALOG RED

7 DDC DATA 17 T.M.D.S. DATA 0- C2 ANALOG GREEN

8 ANALOG VERTICAL SYNC (DVI-I IN Only)

18 T.M.D.S. DATA 0+ C3 ANALOG BLUE

9 T.M.D.S. DATA 1- 19 T.M.D.S. DATA 0/5 SHIELD C4 ANALOG HORIZONTAL SYNC

10 T.M.D.S. DATA 1+ 20 N/C C5 ANALOG GROUND

24 VDC INPUT

GROUNDPOST

COMPOSITEIN

S-VIDEOIN

VGA / RGBSIN

USBIN

SDIIN

5 VDCOUT

DVIRE-DRIVE

DVI / RGBSIN

1 8 C1 C2

C3 C4

9 1617 24

C5C5

Connector Panel Overview | 7

Page 20: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

VGAVGA IN supports RGBS 2, YPbPr signals.

S-Video

Composite

Firmware Connector and Pinout

Mini USBFlash Upgrade Cable, part number 35Z0047, is available from NDS.

Pin Description Pin Description Pin Description

1 RED 6 GND RED 11 N. C.

2 GREEN 7 GND GREEN 12 DDC_SDA

3 BLUE 8 GND BLUE 13 HORIZ SYNC

4 N.C. 9 +5VD 14 VERT SYNC.

5 GND 10 SYNC GND 15 DDC_SCL

Pin Name Description

1 GND Ground (Y)

2 GND Ground (Y)

3 Y Intensity (Luminance)

4 C Intensity (Chrominance)

Pin Name Description

1 DATA Pin

2 GROUND Sleeve

Pin Name Description

1 Vcc +5 VDC

2 D Minus Data Return

3 D Plus Data Transmit

4 ID

5 GND Ground

156

111210

4 32 1

21

1 5

8 | Connector Panel Overview

Page 21: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Power Connector and Pinout

24 VDC Connector

Electrical Symbols

EquipotentialityThis symbol appears next to the display Potential Equalization Conductor (ground post).

Closed (On) SwitchThis symbol appears below the closed, or on, side of the display On/Off switch.Open (Off) SwitchThis symbol appears below the open, or off, side of the display On/Off switch.

Optional 5 VDC Fiber Power Cable

To purchase the optional 5 VDC Fiber Power Cable (P/N 35X0100) contact:

North America and Asia Pacific: [email protected]: [email protected]

Cable Bend RadiusWe recommend that the bend radius of metallic cables be no less than 63 mm (2.5 inches) or 7 timesthe diameter of the cable whichever is greater. The bend radius of Fiber Optic cables should be no lessthan 10 times the diameter of the cable. Sharper bends can damage the cable, and/or degrade thevideo signal.

Pin Name Description

1 +24 VDC Power Input

2 GND Ground

3 Shield Ground

Connector Center (1) Shield (2)

J1 +5 VDC Return

J2 +5 VDC Return

21

3

J2J1

2 1J1 Pinout

5 VDC OUT 5 VDC FIBERNDS 35X0100

1 2J2 Pinout

Connector Panel Overview | 9

Page 22: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

10 | Connector Panel Overview

Page 23: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Specifications

SpecificationsSpecifications are subject to change without notice. Contact factory for current specifications.

Supported Resolutions

DVI Supported Resolutions

EndoVue 19" EndoVue 21" EndoVue 24" EndoVue 32"

Viewing Area (Diagonal) 19.0 (483 mm) 21.5 in. (546 mm) 24.1 in. (612 mm) 31.5 in. (800 mm)

Typical Luminance (cd/m2) 250 250 300 400

Native Resolution 1280 x 1024 1920 x 1080 1920 x 1200 1920 x 1080

Aspect Ratio 5:4 16:9 16:10 16:9

Pixel Pitch (mm) 0.293 0.248 0.270 0.364

Viewing Angle (Horizontal & Vertical) 178° 178° 178° 178°

Contrast Ratio (Nominal) 1000:1 1000:1 1000:1 1000:1

VGA Input Signal Level at 75 Ohms 0.7 V p-p 0.7 V p-p 0.7 V p-p 0.7 V p-p

S-Video Input Signal Level 0.7 V p-p 0.7 V p-p 0.7 V p-p 0.7 V p-p

Composite Input Signal Level 0.7 V p-p 0.7 V p-p 0.7 V p-p 0.7 V p-p

RGBS Input Signal Level 0.7 V p-p 0.7 V p-p 0.7 V p-p 0.7 V p-p

RGBS Input Sync Level 0.4 – 4.0 V p-p 0.4 – 4.0 V p-p 0.4 – 4.0 V p-p 0.4 – 4.0 V p-p

DC Input 24 V (2.7 A) 24 V (2.7 A) 24 V (2.7 A) 24 V (2.7 A)

DC Power Consumption (Nominal)a 26 W 25 W 33 W 52 W

Dimensions (W x H x D) 17.5 x 14.7 x 2.80 in. (445 x 372 x 71 mm)

20.2 x 13.25 x 2.75 in. (513 x 337 x 70 mm)

22.3 x 16.1 x 2.80 in. (566 x 408 x 71 mm)

29.7 x 19.1 x 3.86 in. (753 x 485 x 98 mm)

Display Weightb 10.8 lb (4.9 kg) 12.5 lb. (5.7 kg) 14.8 lb (6.7 kg) 19.4 lb (8.8kg)

Operating Temperature 32 – 95°F (0 – 35°C) 32 – 95°F (0 – 35°C) 32 – 95°F (0 – 35°C) 32 – 95°F (0 – 35°C)

Storage Temperature 4 – 122°F (-20 – 50°C) 4 – 122°F (-20 – 50°C) 4 – 122°F (-20 – 50°C) 4 – 122°F (-20 – 50°C)

Transport Temperature 4 – 122°F (-20 – 50°C) 4 – 122°F (-20 – 50°C) 4 – 122°F (-20 – 50°C) 4 – 122°F (-20 – 50°C)

Operating Humidity (Non-condensing) 20 – 80% 20 – 80% 20 – 80% 20 – 80%

Storage Humidity (Non-condensing) 10 – 90% 10 – 90% 10 – 90% 10 – 90%

Transport Humidity (Non-condensing) 10 – 90% 10 – 90% 10 – 90% 10 – 90%

Operating Altitude (Maximum) 6,600 ft (2,000 m) 6,600 ft (2,000 m) 6,600 ft (2,000 m) 6,600 ft (2,000 m)

Storage Altitude (Maximum) 33,000 ft (10,000 m) 33,000 ft (10,000 m) 33,000 ft (10,000 m) 33,000 ft (10,000 m)

Transport Altitude (Maximum) 33,000 ft (10,000 m) 33,000 ft (10,000 m) 33,000 ft (10,000 m) 33,000 ft (10,000 m)

a. Applies to the BridgePower BM060S24F power supply.b. Monitor only.

Signal Parameter Supported Range

Active Resolution (Horizontal x Vertical) 640 x 480 min to 1920 x 1200 max

Refresh Rate (Vertical Frequency) 23.98 Hz up to 85 HZ

Pixel Clock (Pixel Frequency) 25 MHz up to 165 MHz

The DVI-D input can automatically detect any valid digital DVI signal within the resolution, vertical refresh, and pixel clock ranges specified in the table above. Signals outside of any of the specified ranges may not be supported.

Specifications | 11

Page 24: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

VGA, RGBS, and YPbPr Supported Resolutions

EndoVue Parts List by Region

Horizontal Resolution (pixels)

Vertical Resolution (lines)

Vertical Frequency (Hz)

Horizontal Resolution (pixels)

Vertical Resolution (lines)

Vertical Frequency (Hz)

Horizontal Resolution (pixels)

Vertical Resolution (lines)

Vertical Frequency (Hz)

640 350 50 800 600 85.06 1280 960 60

640 350 60 1024 768i 43.48 1280 960 75

640 350 70 1024 768 50 1280 960 85

640 400 50 1024 768 59.94 1280 1024i 43.44

640 400 70 1024 768 60 1280 1024 60

640 480 50 1024 768 64 1280 1024 60.02

640 480 60 1024 768 70.07 1280 1024 75.02

640 480 67 1024 768 75.03 1280 1024 85.02

640 480 70 1024 768 84.99 1280 480p 59.94

640 480 75 1152 576 50 1280 576p 50

640 480 85.01 1152 864 60.05 1294 960 59.96

720 400 70 1152 864 70.01 1440 900 59.94

720 400 85.04 1152 864 75 1600 1200i 48.04

720 480i 29.97 1152 864 85 1600 1200 60

720 480p 59.94 1152 900 66 1920 1080p 24

720 576i 25 1280 720p 24 1920 1080p 25

720 576p 50 1280 720p 25 1920 1080p 29.97

800 600 56.25 1280 720p 30 1920 1080i 25

800 600 60.32 1280 720p 50 1920 1080i 29.97

800 600 60.38 1280 720p 59.94 1920 1080p 50

800 600 72.19 1280 960i 29.97 1920 1080p 59.94

800 600 75 1280 960 59.94

EndoVue 19" EndoVue 21" EndoVue 24" EndoVue 32"

90K0050 North America 90K0060 North America 90K0070 North America 90K0080 North America

90K0051 South America 90K0061 South America 90K0071 South America 90K0081 South America

90K0052 Japan 90K0062 Japan 90K0072 Japan 90K0082 Japan

90K0053 China 90K0063 China 90K0073 China 90K0083 China

90K0054 Emerging Market 90K0064 Emerging Market 90K0074 Emerging Market 90K0084 Emerging Market

90K0055 Europe 90K0065 Europe 90K0075 Europe 90K0085 Europe

EndoVue Accessory

26B0102 EndoVue Display Stand - 19", 21", 24"

12 | Specifications

Page 25: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Troubleshooting

Image Size is Large for the Screen (VGA, RGBS, YPbPr analog inputs only)If the image does not appear to be the correct format, then SmartSync must be run. To run SmartSync, press theMENU button. In the Picture Menu, press the SCROLL button to highlight SmartSync and press the button.SmartSync will run and optimize the image display properties.

Ghosting in CharactersGhosting in characters is usually attributed to reflections in the video cable or source. Use a high quality cableand, if possible, lower the vertical refresh rate. Lower scan rates can help eliminate reflections. Unlike a CRT, a flat-panel will not flicker at lower refresh rates (60 Hz is optimal), and data will always be frame converted to 60Hz.

Character Jitter (VGA, RGBS, YPbPr analog inputs only)If text characters seem to be “shaky” or bold, then Sharpness, Frequency and/or Phase may require adjusting. See“Setting Frequency, Phase and Sharpness” below.

Character Noise and Vertical Distortion (VGA, RGBS, YPbPr analog inputs only)The Frequency adjustment expands or contracts the horizontal size of the displayed image. The displayed imagemay be too wide or too narrow and vertical banding and pixel jitter may appear in grays and light colors. Adjustthe Frequency until the image just fits the screen. Horizontal position adjustment can be used to verify thatFrequency is set correctly. Line up the image on the left edge of the screen and then shift by one “click” to theright. The image should have one column off the screen on the right side if the Frequency is set correctly.

Testing and Adjusting Frequency (VGA, RGBS, YPbPr analog inputs only)Using a connected laptop, open a blank text file, center the file window in the display, and set the font size andstyle to 8 points Regular. Press the Enter key to move the cursor down to the center of the page, and then pressand hold the Shift and + keys to create a row of + symbols.

Inconsistent lighter or darker display variations of the + symbols is an indication that the Frequency parameterrequires adjustment. Press the MENU button to open the Picture Menu, then press the SCROLL button to select theFrequency parameter. Next, press the or buttons to increase or decrease Frequency until reaching a pointwhere all + symbols display equally.

Note: Sharpness and Phase are subtle adjustments best set using a display calibration program.

Black ScreenPower the monitor Off and On. If the logo screen appears then the display is working properly. Check if thepower management feature (DPMS) is enabled. A “Searching” message appears in the lower right hand cornerwhen a video source is not present.

Troubleshooting | 13

Page 26: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

14 | Troubleshooting

Page 27: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Electromagnetic Compatibility Tables

All medical electronic devices must conform to the requirements of IEC 60601-1-2. Precautions, adherences tothe Electromagnetic Compatibility (EMC) guideline information provided in this manual and verification of allmedical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co-existence of all other medical devices prior to a surgical procedure.

The following EMC tables are provided for your reference:

• “Electromagnetic Emissions” on page 16• “Electromagnetic Immunity” on page 16• “Recommended Separation Distances” on page 17

Electromagnetic Compatibility Tables | 15

Page 28: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Electromagnetic Emissions

Electromagnetic Immunity

Guidance and manufacturer’s declaration; electromagnetic emissions

The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment.

Emissions Compliance Electromagnetic environment-- guidance

RF emissions

CISPR 11

Group 1 The product uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.

RF emissions

CISPR 11

Class B The product is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.

Harmonic emissions

IEC 61000-3-2

Not applicable

Voltage fluctuations/ flicker emissions

IEC 61000-3-3

Not applicable

Guidance and manufacturer’s declaration; electromagnetic immunity

The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment.

Immunity test IEC 60601 test level

Compliance level

Electromagnetic environment - guidance

Electrostatic discharge (ESD)

IEC 61000-4-2

±6 kV contact

±8 kV air

±6 kV contact

±8 kV air

The product uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.

Electrical fast transient/burst

IEC 61000-4-4

±2 kV for power supply lines

±2 kV for power supply lines

The product is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.

Surge

IEC 61000-4-5

±1 kV line(s) and neutral

±1 kV line(s) and neutral

Mains power quality should be that of a typical commercial or hospital environment

Voltage dips, short interruptions and voltage variations on power supply input lines

IEC 61000-4-11

<5% UT (>95% dip in UT) for 0,5 cycle

40% UT (60% dip in UT) for 5 cycles

70% UT(30% dip in UT) for 25 cycles

<5% UT(>95% dip in UT) for 5 sec

<5% UT(>95% dip in UT) for 0,5 cycle

40% UT(60% dip in UT) for 5 cycles

70% UT(30% dip in UT) for 25 cycles)

<5% UT(>95% dip in UT) for 5 sec

Mains power quality should be that of a typical commercial or hospital environment. If a dips or an interruption of mains power occurs, the current of the product may be dropped off from normal level, it may be necessary to use uninterruptible power supply or a battery.

Power frequency (50/60 Hz) magnetic field

IEC 61000-4-8

3 A/m Not applicable Not applicable

NOTE: UT is the AC mains voltage prior to application of the test level

16 | Electromagnetic Compatibility Tables

Page 29: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Recommended Separation Distances

Guidance and manufacturer’s declaration; electromagnetic immunity (continued)

The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment.

Immunity test  IEC 60601 test level  Compliance level Electromagnetic environment - guidance

Portable and mobile RF communications equipment should be used no closer to any part of the product, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.

Recommended separation distance

Conducted RF 3 Vrms 3 Vrms

IEC 61000-4-6 150 kHz to 80 MHz

Radiated RF 3 V/m 3 V/m 80 MHz to 800 MHz

IEC 61000-4-3 80 MHz to 2.5 GHz 800 MHz to 2,5 GHz

Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer, and d is the recommended separation distance in meters (m).

Field strengths from fixed RF transmitters, as determined by an  electromagnetic site surveya should be less than the compliance level in each frequency rangeb.

Interference may occur in the vicinity of equipment marked with this symbol.

NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and

reflection from structures, objects and people.

a. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the product is used exceeds the applicable RF compliance level above, the product should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the product.

b. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.

Recommended separation distances between portable and mobile RF communications equipment and the product

The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the product can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the product as recommended below, according to the maximum output power of the communications equipment.

Rated maximum output power (W) of transmitter

Separation distance, in meters according to frequency of transmitter 

150 kHz to 80 MHz 80 MHz to 800 MHz  800 MHz to 2.5 GHz 

0.01 0.12 0.12 0.23

0.10 0.38 0.38 0.73

1.00 1.20 1.20 2.30

10.00 3.80 3.80 7.30

100.00 12.00 12.00 23.00

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and

reflection from structures, objects and people.

d 1 2 P,=

d 1 2 P,=

d 2 3 P,=

Electromagnetic Compatibility Tables | 17

Page 30: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

18 | Electromagnetic Compatibility Tables

Page 31: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1
Page 32: EndoVue User Manual - NDS Surgical Imagingndssi.com/data/uploads/endovue-user-manual-60a0585-c-english.pdfEndoVue® USER MANUAL ENGLISH ... accordance with CAN/CSA C22.2 No. 60601-1

Contact

60A0585 Rev C

Global Headquarters

www.ndssi.com

5750 Hellyer Ave

San Jose, CA 95138

USA

+1 408 776 0085

[email protected]

Europe

Novanta Europe GmbH

Münchner Strasse 2A

82152 Planegg

Germany

+49 89 31 707 100

[email protected]

Asia Pacific

Novanta Japan

East Square Omori

6-20-14 Minamioi, Shinagawa-ku

Tokyo 140-0013

Japan

+81 3 5753 2466

[email protected]

Oriental Media Center

Suite 2302, Tower C

No.4, Guang Hua Road

Chao Yang District

Beijing, 100026

China

+86 10 8559 7859

[email protected]

NDS Quality System

ISO 9001:2008 and ISO 13485:2003

FDA Registration #2954921