Upload
dhdgdgd
View
159
Download
0
Embed Size (px)
Citation preview
ENDOPORE®, ENDOPORE® Hybrid & ENTEGRA™ Implant Systems
Product Catalog & Prosthetic Procedures
Welcome to the latest edition of the ENDOPORE®, ENDOPORE® HYBRID & ENTEGRA™ Product Catalog. This catalog contains items for implant surgery and prosthetic procedures. Innova, the implant platform of Sybron Dental Specialties, is dedicated to providing innovative solutions to dental professionals and to excellence in customer service.
Contents
Endopore Implants with Internal Connection
6 EndoporeImplantswithInternalConnectionforOne-StageSurgery
7 CasePlanningChart
Crown and Bridge Restorations 9 CoverScrews/HealingAbutments 9 CementableAbutments 9 ECOAbutmentSystem10 OctabutmentSystem
Overdenture Restorations 11 LocatorSystem12 O-RingAbutmentSystem12 DallaBonaAbutmentSystem
Endopore, Endopore Hybrid Implants with Internal Hex
13 EndoporeandEndoporeHybridInternalHexImplantsforTwo-StageSurgery
14 CasePlanningChart
Crown and Bridge Restorations 16 CoverScrews 16 HealingAbutments17 TransferCopings17 ImplantAnalogs17 RetainingScrews18 HexedAbutments18 AngledAbutments 19 UCLAAbutments
Overdenture Restorations 20 LocatorSystem 21 O-RingAbutmentSystem21 DallaBonaAbutmentSystem22 UMASystem
Endopore, Endopore Hybrid and Entegra Implants with External Hex
23 Endopore,EndoporeHybridandEntegraExternalHeximplantsforTwo-StageSurgery
24 Endopore25 EndoporeHybrid26 Entegra29 CasePlanningChart
Crown and Bridge Restorations32 CoverScrews32 HealingAbutments 33 TransferCopings34 ImplantAnalogs34 RetainingScrews35 HexedAbutments36 AngledAbutments36 TemporaryTitaniumAbutments37 UCLAAbutments
Overdenture Restorations 38 LocatorSystem38 O-RingAbutmentSystem39 DallaBonaAbutmentSystem40 OverdentureAbutmentSystem41 UMASystem
43 Prosthetic Instrumentation45 Prosthetic Procedures
Surgical64 EndoporeSurgicalKits65 EndoporeSurgicalInstrumentation68 EndoporeHybridSurgicalKits69 EndoporeHybridSurgicalInstrumentation72 EntegraSurgicalKit73 EntegraSurgicalInstrumentation75 SurgicalMotors&Equipment76 RegenerationProducts
78 OrderForm
3
Table of Contents ENDOPORE®
Note:Productspecificationsaresubjecttochangewithoutnotice.Notallitemsillustratedatactualsize.
Quality Assurance GuaranteeInnovamanufacturingfacilitiesareISOcertifiedandproductsinthiscatalogarelabeledwiththeCElogo,thesymbolofapprovalbytheEuropeanEconomicCommunity.
Implant GuaranteeInNorthAmerica,Innovaguaranteesallimplantsforthelifetimeofthepatient.Ifanimplantshouldfailatanytime,InnovawillreplacethefailedimplantandcomponentsfromInnovaatnochargetothepractitioner.Tomakeaclaim,pleasecontacttheInnovaCustomerServiceCentertoobtainaguaranteequestionnaire.
Continuing EducationInnovaisactivelyinvolvedinresearchanddevelopmentofnewtechnologiestoincreasetreatmentalternativesforyouandyourpatients.Newtechnologiesrequireeducation,therefore,Innovaispleasedtosponsorbothintroductoryandadvancedcontinuingeducationcoursesgivenbyworldrenownedclinicians.
InNorthAmerica,InnovaisarecognizedprogramproviderbytheAcademyofGeneralDentistryundertheProgramApprovalforContinuingEducation(PACE).CanadiancoursesareeligiblefortheRoyalCollegeofDentalSurgeons(RCDS)accreditation.
Toinquireaboutourwiderangeofeducationalproductsandservicestoassistinsurgicalandprosthetictreatments,pleasecontactInnova’sDepartmentofContinuingEducationat800.718.5157orseminars@innovalife.com.
Innova’s Commitment
4
ENDOPORE® Innova’s Commitment
International OrdersForordersoutsideofNorthAmerica,pleasecontactInnovaforyourlocaldealer.
North American OrdersInnova North American Customer Service CenterTollFree:800.898.6261 E-mail:[email protected]:416.340.8818 Web:www.innovalife.comFax:416.340.0415
To Place An OrderOrdersmaybeplacedbytelephone,fax,e-mail,throughtheorderformonInnova’swebsite(www.innovalife.com)orwithanInnovaRepresentative.Foryourconveniencewehaveincludedanorderforminthiscatalog,whichmaybephotocopiedandusedforfutureorders.All orders placed before 2:00 pm EST will be processed for shipment the same day.
BillingMasterCard,AmericanExpressandVisacreditcardsareaccepted.Allinvoicesarepayablenet30days.Pastduebalanceswillbesubjecttoa1.5%financechargepermonth,anamountequalto18%perannum.
ShippingUnlessotherwisespecified,ordersareshippedFOB,Tonawanda,NY(U.S.A.orders)orFOB,Toronto,Canada(Canadian&Internationalorders),freightcollectorprepaidwiththeshippingcostaddedtotheinvoice.Allinternalandexternalpackagingiscarefullyinspectedpriortoshipment.Ifyourpackageisreceiveddamaged,donotacceptitandimmediatelycalltheInnovaCustomerServiceCenter.Ifthereareanyshortagesorquestions,pleasenotifytheInnovaCustomerServiceCenterwithin10daysofreceipt.
Return PolicyPleasecontacttheInnovaCustomerServiceCenterforaMaterialReturnAuthorizationNumberandshippinginstructionspriortoreturninganyproduct.Productreturnedmustbeunopenedandundamagedandmustbereceivedwithin90daysoftheinvoicedateforreplacementorcredit.All returned products are subject to our standard 15% handling and restocking charges. No product will be accepted for return after 90 days from the invoice date.
Ordering Procedures
5
Ordering Procedures ENDOPORE®
Endopore Implants with Internal Connection for One-Stage Surgery
TheEndoporeimplantshaveastandardMorseTaperimplant-to-abutmentinterfaceandaresuppliedinboth4.1mmand5.0mmimplantdiameters,eachhavinga4.8mmabutmentplatformdiameter.Thisallowsboth
AP – Abutment Platform Ø
TC – Transgingival Collar
Length
TC
4.8 mm AP
Diameter
the4.1mmand5.0mmdiameterimplantstoacceptthesameprostheticcomponents.Eachimplantdiameterisavailablewitha1.8mmor2.8mmtransgingivalcollar.A1mmlowprofilecoverscrewispackagedwitheachimplant.
AP TC Length Item-No.
Implant Ø 4.1 mm4.8mm 1.8mm 7mm 01S-7I1.84.8mm 2.8mm 7mm 01S-7I2.8
4.8mm 1.8mm 9mm 01S-9I1.84.8mm 2.8mm 9mm 01S-9I2.8
4.8mm 1.8mm 12mm 01S-12I1.84.8mm 2.8mm 12mm 01S-12I2.8
Implant Ø 5.0 mm4.8mm 1.8mm 5mm 01WS-5I1.84.8mm 2.8mm 5mm 01WS-5I2.8
4.8mm 1.8mm 7mm 01WS-7I1.84.8mm 2.8mm 7mm 01WS-7I2.8
4.8mm 1.8mm 9mm 01WS-9I1.84.8mm 2.8mm 9mm 01WS-9I2.8
4.8mm 1.8mm 12mm 01WS-12I1.84.8mm 2.8mm 12mm 01WS-12I2.8
6
ENDOPORE® One-Stage: Internal Connection
Case Planning Chart
StraightCementable
ECO Abutment Octabutment
Crown Bridge
BridgeCrown Bar
Locking Non-Locking
AngledCementable
One-Stage Surgery
Coping Coping/I
Crown Bridge
7
One-Stage: Internal Connection ENDOPORE®
Case Planning Chart
O-RingSystem
Dalla Bona System
Overdenture
One-Stage Surgery
Laboratory Processing
Final Restoration
Locator System
Impression Stage
8
ENDOPORE® One-Stage: Internal Connection
Crown and Bridge Restorations
Cover Screw/Healing AbutmentsA1mmcoverscrewispackagedwitheachimplant.
1mm 02S-1HS2mm 02S-2HS3mm 02S-3HS4mm 02S-4HS
Cover Screws /Healing Abutments Length Item-No.
Cementable Abutments Length Item-No.
Straight Cementable Abutments
Angled Cementable AbutmentsAngle15°Angle25°
4.0mm 05S-4.0FS5.5mm 05S-5.5FS7.0mm 05S-7.0FS
05S-15FA 05S-25FA
ECO Abutment System Item-No.
ECO Abutment and CapLength5.0mm(7.0mmwithcap)
ECO Analog
ECO Coping – Indexed
ECO Coping – Non Indexed
05S-5ABUT/WC
06S-ANALOG
06S-COPING/I
06S-COPING
5.0 mm
7.0 mm
ECO Coping – Indexed
ECO Coping – Non Indexed
ECO Abutment ECO Analog
15°
9
One-Stage: Internal Connection ENDOPORE®
Octabutment System Item-No.
Octabutment
Octabutment Cap with Screw
Octabutment Transfer Coping WithGuidePin
Octabutment Analog
Temporary Abutment for Octabutment Locking
Temporary Abutment for Octabutment Non-locking
Note:Temporaryabutmentsincludeanoctabutmentretainingscrew.
Plastic Coping for Octabutment Locking
Plastic Coping for Octabutment Non-locking
Note:Plasticcopingsincludeanoctabutmentretainingscrew.
Octabutment Retaining Screw
Insertion Tip FortheECOandCementableAbutment
Insertion Tip for Octabutment
Driver Housing
0.05“ Hex Tip
07S-0010
07S-2100
07S-0090
07S-0015
07S-0303
07S-0353
07S-0203
07S-0253
07S-0053
07S-0176
07S-0175
07-0190 06-TWHT
Hex Tip12.5 mm
locking non-locking
locking non-locking
Octabutment Cap with screw
Transfer Coping Analog
Insertion Tip Insertion Tip for
Octabutment
Driver Housing 0.05“ Hex Tip
TheOctabutmentSystemisusedforallprocedureswhereascrew-retainedprosthesisisrequired,orwhereaworkingmodelincorporatinganabutmentanalogisdesired.
Accessories
10
ENDOPORE® One-Stage: Internal Connection
Overdenture Restorations
LOCATOR® Abutments Impl. Ø mm Collar Item-No.
TheLocatorabutmentisanattachmentwithaself-aligningfeature.Thisfeaturewillaidpatientsinseatingtheirdentureandeliminateadditionalwearfromimproperseating.
WiththeLocator’sminimalverticalheight,itisidealwhereinterocclusalspaceislimited.Thisabutmentcanalsoaccommodateupto40°betweenimplants.
*NotavailableintheUSA.
4.1/5.0mm 0.73mm 08-8950*4.1/5.0mm 2mm 08-8951*4.1/5.0mm 3mm 08-8952*4.1/5.0mm 4mm 08-8953*4.1/5.0mm 5mm 08-8954*
Locator Parallel Post4Pack
Locator Impression Coping 4Pack
Locator Female Analog5mmDiameter.4Pack
Locator Core Tool
Locator Abutment Driver15mm
21mm
Abutment DriverForlatch,23mm
08-8517
08-8505
08-8516
08-8393
08-8926
08-8927
08-8913
Female AnalogØ 5 mm
Locator Impression Coping
Locator Parallel Post
LOCATOR® Attachments Item-No.
Locator Male Processing Package, 10 setsLocator Male Processing Package, 2 setsEachsetincludes:1processingReplacementMale08-8515,1ReplacementMale08-8524/08-8527/08-8529,1WhiteBlockOutRing08-8514,1FinalCap
Locator Replacement MaleClear,4Pack
Locator Light Retention Replacement MalePink,4Pack
Locator Extra Light Retention Replacement MaleBlue,4Pack
08-8519-1008-8519-2
08-8524
08-8527
08-8529
LOCATOR® Attachments Item-No.
Locator Extended Range Replacement MaleGreen,4Pack
Locator Extra Light Extended Range MaleRed,4Pack
Locator Black Processing Replacement Male4Pack
White Black Out Ring 20Pack
Angle Measurement Guide
08-8547
08-8548
08-8515
08-8514
08-9530
4.8 mmAbutment Platform
11
One-Stage: Internal Connection ENDOPORE®
O-Ring Abutment and Dalla Bona Systems Item-No.
TheORSandtheDallaBonaabutmentslieflushwiththetopoftheimplantwhentheabutmentsareinsertedintotheEndoporeOne-Stageimplants.
O-Ring Abutment System EachO-RingSystemincludesatitaniummaleabutmentandanORSlabkitwhichincludesabrassabutmentanalog,metalhousing,3redO-Ringsand3whiteO-Rings.
Dalla Bona Abutment System EachDallaBonaSystemincludesatitaniummaleabutment,abrassabutmentanalog,atitaniumfemalewithaPVCringandaspacer.
Driver Housing
ORS and Dalla Bona Abutment Driver
Dalla Bona Activating ToolAninstrumentusedtoincreasetheretentionofanattachment
Dalla Bona Deactivating Tool Aninstrumentusedtoreducetheretentionofanattachment
Overdenture Restorations
07S-4000
07S-3000
07-0190
07-0140
07-1017
07-1018
Accessories Item-No.
NotePleaserefertopages38–39forDallaBonaAbutmentSystemandO-RingAbutmentSystem.
NoteTheredO-Ringisusedforlaboratoryset-upandthewhiteO-Ringisusedforthefinishedoverdenture.
12
ENDOPORE® One-Stage: Internal connection
Endopore and Endopore Hybrid Implants with Internal Hexfor Two-Stage Surgery
SCR – Smooth Coronal Region
Implant Ø 4.1 mm 2mm 7mm 01l-7I22mm 9mm 01l-9I22mm 12mm 01l-12I2
Implant Ø 5.0 mm 2mm 7mm 01Wl-7I22mm 9mm 01Wl-9I22mm 12mm 01Wl-12I2
SCR Length Item-No.
EndoporeandEndoporeHybridImplantswithInternalHexaresuppliedinboth4.1mmand5.0mmimplantplatforms.Alowprofilecoverscrewispackagedwitheachimplant.
Length
SCR
Diameter
AP – Abutment Platform
Implant Ø 4.0 mm 4.1mm 9.5mm 01l-9.5HYB4.1mm 11mm 01l-11HYB
Implant Ø 4.75 mm 5.0mm 7.5mm 01Wl-7.5HYB5.0mm 9.5mm 01Wl-9.5HYB
AP Length Item-No.
Length
Diameter
AP
13
Two-Stage: Internal Hex ENDOPORE®/ENDOPORE® Hybrid
Case Planning Chart
15° 25°
BridgeCrown
One- and Two-Stage Surgery
Impression Stage
Laboratory Processing
Final Restoration
Flared Healing
Abutment
Straight Healing
Abutment
Flared Transfer
Coping Assembly
Straight Transfer
Coping Assembly
Flared Hexed
Abutment
Angled Hexed
Abutment
Angled Hexed
Abutment
Straight Hexed
Abutment
Hexed UCLA
Abutment
Non-Hexed UCLA
Abutment
14
Two-Stage: Internal HexENDOPORE®/ENDOPORE® Hybrid Two-Stage: Internal Hex
Case Planning Chart
Overdenture
Impression Stage
Laboratory Processing
Final Restoration
Straight Healing
Abutment
Dalla Bona
System
O-Ring
System (ORS)
Locator
System
One- and Two-Stage Surgery
15
Two-Stage: Internal Hex ENDOPORE®/ENDOPORE® Hybrid
Crown and Bridge Restorations
Cover Screws Impl. Ø mm Item-No.
Cover Screw (replacement)Alowprofilecoverscrewispackagedwitheachimplant.
4.1mm 02I-CS5.0mm 02WI-CS
Healing Abutments Impl. Ø mm Length Width Item-No.
Straight Healing AbutmentsThestraighthealingabutmentisusedinallsituationsexceptwhereanexpandedgingivalcuffisdesired.
Flared Healing AbutmentsTheuseofaflaredhealingabutmentallowsthegingivatohealaroundthisexpandedprofile,whereamorenaturalemergenceprofileispreferred.
4.1mm 3mm 4.1mm 02B-3HS4.1mm 5mm 4.1mm 02B-5HS4.1mm 7mm 4.1mm 02B-7HS
5.0mm 3mm 5.0mm 02WB-3HS5.0mm 5mm 5.0mm 02WB-5HS5.0mm 7mm 5.0mm 02WB-7HS
4.1mm 4mm 5.3mm 02B-4H4.1mm 6.5mm 5.3mm 02B-6.5H
5.0mm 4mm 6.8mm 02WB-4H5.0mm 6.5mm 6.8mm 02WB-6.5H
Length
Width
Length
Width
Flared Healing
Abutment
Straight Healing
Abutment
16
ENDOPORE®/ENDOPORE® Hybrid Two-Stage: Internal Hex
Transfer Copings Impl. Ø mm Length Item-No.
Straight Transfer CopingsForusewithstraighthealingabutments
Flared Transfer CopingsForusewithflaredhealingabutments
Transfer Coping Screw, LongForoptionalusewithtransfercopings,whenan“opentray”techniqueisused
4.1mm 11mm 06I-CTCA/S5.0mm 11mm 06WI-CTCA/S
4.1mm 11mm 06I-CTCA/F5.0mm 11mm 06WI-CTCA/F
4.1/5.0mm 16mm 06B-TC/SL
Implant Analogs Impl. Ø mm Length Qty. Item-No.
Implant AnalogsMaterial:StainlessSteel
Implant AnalogsMaterial:AluminumColor:gold
Implant AnalogsMaterial:AluminumColor:silver
4.1mm 9mm 1 06I-PIA4.1mm 9mm 5 06I-PIA/55.0mm 9mm 1 06WI-PIA5.0mm 9mm 5 06WI-PIA/5
4.1mm 9mm 1 06I-IA/14.1mm 9mm 5 06I-IA
5.0mm 9mm 1 06WI-IA/15.0mm 9mm 5 06WI-IA
Retaining Screws (replacement) Impl. Ø mm Item-No.
ForusewithhexedandUCLAabutments
Titanium Alloy Replacement Screw
Gold Alloy Replacement Screw
Allabutmentsarepackagedwithatitaniumretainingscrew.
4.1/5.0mm 05B-2RS
4.1/5.0mm 05B-2RS/G
Straight Transfer
Coping
Flared Transfer
Coping
Transfer Coping
Screw, Long
Theshapeofthetransfercopingmatchestheshapeofthecorrespondinghealingabutmentandthisallowstheprofileofthegingivalcufftobeaccuratelyreproducedintheworkingmodel.
17
Two-Stage: Internal Hex ENDOPORE®/ENDOPORE® Hybrid
4.1mm 7mm 1.5mm 05I-7FN4.1mm 9mm 3.5mm 05I-9FN4.1mm 11mm 5.5mm 05I-11FN
5.0mm 7mm 1.5mm 05WI-7FN5.0mm 9mm 3.5mm 05WI-9FN5.0mm 11mm 5.5mm 05WI-11FN
4.1mm 8.5mm 2mm 05I-8.5UN
5.0mm 8.5mm 2mm 05WI-8.5UN
Hexed Abutments Impl. Ø mm Length Collar Item-No.
Theseabutmentsareusedforcementretainedcrownorbridgerestorations.
Straight Hexed AbutmentsRetainingscrewincludedThestraighthexedabutmenthasaparallelsidedtransgingivalcollar.
Flared Hexed AbutmentsRetainingscrewincludedTheflaredhexedabutmentisdesignedforrestorationsrequiringanaturalemergenceprofile.
Length
Collar
Length
Collar
Angled Abutments Impl. Ø mm Length Angle Item-No.
Angled Hexed AbutmentsRetainingscrewincludedAngledabutmentscompensateforlargedivergencesinimplantalignment.AngledguidepinsareavailableintheProstheticInstrumentationsection(pg.43-44)ofthiscatalog.
4.1mm 11mm 15° 05I-15FA4.1mm 11mm 25° 05I-25FA
5.0mm 11mm 15° 05WI-15FA5.0mm 11mm 25° 05WI-25FA
15° 25°
18
ENDOPORE®/ENDOPORE® Hybrid Two-Stage: Internal Hex
UCLA Abutments Impl. Ø mm Item-No.
UCLA Abutments
UCLAabutmentsprovideafoundationtowhichwaxcanbeaddedtoshapeascrew-retainedcrownorbridgeoracustomabut-ment.Areamerisavailabletocleanouttheretainingscrewholeinthecasting.Goldbaseabutmentshavemachinedsurfaces.
UCLA Plastic Abutments RetainingscrewincludedHexed
Non-Hexed
UCLA Gold Base AbutmentsNon-Ceramic AlloyRetainingscrewincludedHexed
Non-Hexed
4.1mm 06I-UCLA/H5.0mm 06WI-UCLA/H
4.1mm 06I-UCLA5.0mm 06WI-UCLA
4.1mm 06I-UCLA/H/GNC5.0mm 06WI-UCLA/H/GNC
4.1mm 06I-UCLA/GNC5.0mm 06WI-UCLA/GNC
UCLA Plastic
Abutment
Hexed
UCLA Plastic
Abutment
Non-Hexed
UCLA Gold Base
Abutment
Hexed
UCLA Gold Base
Abutment
Non-Hexed
ImportantThemeltingrangeis1,400–1,490˚C(2,550–2,710˚F),refertopackageinstructionsforfurtherdetails.
HexedUCLAabutmentsshouldbeusedforcustomabutmentsandforsupportingcrownsastheywillresisttherotationalforcesassociatedwithsingletoothrestorations.
19
Two-Stage: Internal Hex ENDOPORE®/ENDOPORE® Hybrid
Overdenture Restorations
TheLocatorabutmentisanattachmentwithaself-aligningfeature.Thisfeaturewillaidpatientsinseatingtheirdentureandeliminateadditionalwearfromimproperseating.
WiththeLocator’sminimalverticalheight,itisidealwhereinterocclusalspaceislimited.Thisabutmentcanalsoaccommodateupto40°betweenimplants.
LOCATOR® Abutments Impl. Ø mm Collar Item-No.
4.1mm 0.73mm 08-81454.1mm 1mm 08-81464.1mm 2mm 08-81474.1mm 3mm 08-81484.1mm 4mm 08-81494.1mm 5mm 08-8150
5.0mm 1mm 08-81645.0mm 2mm 08-81655.0mm 3mm 08-81665.0mm 4mm 08-81675.0mm 5mm 08-81685.0mm 6mm 08-8169
Locator Parallel Post4Pack
Locator Impression Coping 4Pack
Locator Female Analog4mmDiameter.4Pack5mmDiameter.4Pack
Locator Core Tool
Locator Abutment Driver15mm
21mm
Abutment DriverForlatch,23mm
08-8517
08-8505
08-853008-8516
08-8393
08-8926
08-8927
08-8913
Female AnalogØ 5 mm
Locator Impression Coping
Locator Parallel Post
LOCATOR® Attachments Item-No. LOCATOR® Attachments Item-No.
Locator Male Processing Package, 10 setsLocator Male Processing Package, 2 setsEachsetincludes:1processingReplacementMale08-8515,1ReplacementMale08-8524/08-8527/08-8529,1WhiteBlockOutRing08-8514,1FinalCap
Locator Replacement MaleClear,4Pack
Locator Light Retention Replacement MalePink,4Pack
Locator Extra Light Retention Replacement MaleBlue,4Pack
08-8519-1008-8519-2
08-8524
08-8527
08-8529
Locator Extended Range Replacement MaleGreen,4Pack
Locator Extra Light Extended Range MaleRed,4Pack
Locator Black Processing Replacement Male4Pack
White Black Out Ring, 20Pack
Angle Measurement Guide
08-8547
08-8548
08-8515
08-8514
08-9530
20
ENDOPORE®/ENDOPORE® Hybrid Two-Stage: Internal Hex
O-Ring Abutment System (ORS) Impl. Ø mm Collar Length Item-No.
O-Ring Abutment SystemTheredO-Ringisusedforlaboratoryset-upandthewhiteO-Ringisusedforthefinishedoverdenture.TheO-Ringabutmentsystemcanaccommodateupto5degreesofdivergencebetweenimplants.
EachO-RingSystemincludesatitaniummaleabutmentandanORSlabkitwhichincludesabrassabutmentanalog,metalhousing,3redO-Ringsand3whiteO-Rings.
4.1mm 1mm 4mm 04I-1ORS4.1mm 2mm 5mm 04I-2ORS4.1mm 3mm 6mm 04I-3ORS4.1mm 4mm 7mm 04I-4ORS4.1mm 5mm 8mm 04I-5ORS4.1mm 6mm 9mm 04I-6ORS4.1mm 7mm 10mm 04I-7ORS
5.0mm 1mm 4mm 04WI-1ORS5.0mm 2mm 5mm 04WI-2ORS5.0mm 3mm 6mm 04WI-3ORS5.0mm 4mm 7mm 04WI-4ORS5.0mm 5mm 8mm 04WI-5ORS5.0mm 6mm 9mm 04WI-6ORS
Dalla Bona Abutment System Impl. Ø mm Collar Length Item-No.
Dalla Bona Abutment SystemTheDallaBonaabutmentisaball&sockettypeconnector.Itssphericaldesignallowsupto15degreesdivergencebetweentheabutments.
EachDallaBonaSystemincludesatitaniummaleabutment,abrassabutmentanalog,atitaniumfemalewithaPVCringandaspacer.
4.1mm 1mm 4mm 04I-1DB4.1mm 2mm 5mm 04I-2DB4.1mm 3mm 6mm 04I-3DB4.1mm 4mm 7mm 04I-4DB4.1mm 5mm 8mm 04I-5DB4.1mm 6mm 9mm 04I-6DB4.1mm 7mm 10mm 04I-7DB
5.0mm 1mm 4mm 04WI-1DB5.0mm 2mm 5mm 04WI-2DB5.0mm 3mm 6mm 04WI-3DB5.0mm 4mm 7mm 04WI-4DB5.0mm 5mm 8mm 04WI-5DB5.0mm 6mm 9mm 04WI-6DB5.0mm 7mm 10mm 04WI-7DB
O-Ring Accessories Item-No.
O-Ring Lab Kit
Metal Housing
White O-Rings10pack
06-ORS
07-0044
06-O/ORS
Dalla Bona Plus Accessories Item-No.
Dalla Bona PlusKeepingthesamebenefitsastheDallaBonaSystem,theDallaBonaPlusfemaleattachmentisagoldinsertthatcanbeeasilyreplacedandadjustedwithDallaBonaPlusActivating/DeactivatingTool.
Dalla Bona Plus Activating/Deactivating ToolAninstrumentusedtoincreaseandreducetheretentionofanattachment.
07-0482
07-0489
21
Two-Stage: Internal Hex ENDOPORE®/ENDOPORE® Hybrid
UMA System Impl. Ø mm Collar Item-No.
UMA System AbutmentsTheUMA(UniversalModificationAbutment)systemisusedforscrewretainedrestorationswhereitisdesiredtohavethepointsofattachmentsuperiortothesofttissue.WherethereisinsufficientclearancetouseaUMAorwhenasub-gingivalseparationisdesired,aUCLAabutmentcanbeusedtoachieveseparationoftherestorationattheimplantlevel.
TheUMAisatransmucosalcollarthatshouldbesecuredtotheimplantwith30Ncmoftorque.TheUMAscrewusedtosecuretherestorationtotheabutmentispackagedwitheachUMAplasticcoping.A0.05“hexdriverisusedtosecurethescrewwhichshouldonlybetightenedto20Ncm.
4.1mm 2.0mm 02I-2.0UMA4.1mm 3.0mm 02I-3.0UMA4.1mm 4.0mm 02I-4.0UMA4.1mm 5.0mm 02I-5.0UMA4.1mm 6.0mm 02I-6.0UMA4.1mm 7.0mm 02I-7.0UMA4.1mm 8.0mm 02I-8.0UMA
5.0mm 2.0mm 02WI-2.0UMA5.0mm 3.0mm 02WI-3.0UMA5.0mm 4.0mm 02WI-4.0UMA5.0mm 5.0mm 02WI-5.0UMA5.0mm 6.0mm 02WI-6.0UMA
Pleaserefertopages41–42forUMASystemcomponents.
Dalla Bona Lab KitIncludesabrassabutmentanalog,atitaniumfemalewithaPVCringandaspacer.
Dalla Bona Activating Tool Aninstrumentusedtoincreasetheretentionofanattachment.
Dalla Bona Deactivating Tool Aninstrumentusedtoreducetheretentionofanattachment.
07-1012
07-1017
07-1018
Dalla Bona Accessories Item-No.
22
ENDOPORE®/ENDOPORE® Hybrid Two-Stage: Internal Hex
Endopore, Endopore Hybrid and Entegra Implants with External Hex for Two-Stage Surgery
Endopore,EndoporeHybridandEntegraImplantswithexternalhexarecompatiblewithawidevarietyofprostheticproductsforcrownandbridgeandoverdenturerestorationsincludingUCLA,UMA,DallaBona,Locator,OverdentureandO-RingAbutmentSystems.Allimplantsarepackagedwithcolourcodedlabelsthatidentifytheirdiameters.Allprostheticcomponentsmustbematchedtothediameterofimplanttowhichtheyaretobeconnected.Abutmentlabelshavethesamecolorcodingasthecorrespondingimplants.
23
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Implant Ø 3.5 mm 1mm 9mm 01M-9I1
Implant Ø 4.1 mm 1mm 7mm 01B-7I12mm 7mm 01B-7I2
1mm 9mm 01B-9I12mm 9mm 01B-9I2
1mm 12mm 01B-12I12mm 12mm 01B-12I2
Implant Ø 5.0 mm 1mm 5mm 01WB-5I1
1mm 7mm 01WB-7I12mm 7mm 01WB-7I2
1mm 9mm 01WB-9I12mm 9mm 01WB-9I2
1mm 12mm 01WB-12I12mm 12mm 01WB-12I2
SCR Length Item-No.
Endopore Implants with External Hex
SCR – Smooth Coronal Region
3.5 mm diameter implant
The3.5mmdiameterimplantispackagedinaredlabeledbox(01M-range).Thisimplanthasa0.9mmhighx2.0mmflat-to-flathexandaUNFthread.
4.1 mm diameter implant
The4.1mmdiameterimplantswiththeindustrystandardhexarepackagedingreenlabeledboxes(01B-range).Theseimplantshavea0.7mmhighx2.7mmflat-to-flathexandametricthread.
5.0 mm diameter implant
The5.0mmdiameterimplantsarepackagedinturquoiselabeledboxes(01WB-range).Theseimplantshavea0.9mmhighx2.7mmflat-to-flathexandmetricthread.
TheEndoporeExternalHexConnectionimplantsareavailableinthreediameters:3.5mm,4.1mmand5.0mm.
Alowprofilecoverscrewispackagedwitheachimplant.The4.1mmand5.0mmdiameterareavailablewitha1mmor2mmsmoothcoronalregion.The3.5mmdiameterimplantisavailableina1mmsmoothcoronalregion.
Length
SCR
Diameter
Length
SCR 2 mm
Diameter
Length
SCR 1 mm
Diameter
24
ENDOPORE® Two-Stage: External Hex
Implant Ø 4.0 mm 4.1mm 9.5mm 01B-9.5HYB4.1mm 11mm 01B-11HYB
Implant Ø 4.75 mm 5.0mm 7.5mm 01WB-7.5HYB5.0mm 9.5mm 01WB-9.5HYB
AP – Abutment Platform
Length
Diameter
AP
Endopore Hybrid with External Hex
AP Length Item-No.
TheEndoporeHybridExternalHexConnectionimplantsareavailableintwodiameters:4.0mmand4.75mm.
Theimplantsarepackagedwithcolorcodedlabelsthatidentifytheirdiameters.Theseimplantshavea0.9mmsmoothcoronalregion.Alowprofilecoverscrewispackagedwitheachimplant.
4.1 mm diameter implant
The4.0mmdiameterimplantispackagedinagreenlabeledbox(01B-range).Theseimplantshaveanindustrystandardhex(0.7mmhighx2.7mmflat-to-flathex)andametricthread.
5.0 mm diameter implant
The4.75mmdiameterimplantispackagedinaturquoiselabeledbox(01WB-range).Theseimplantshavea0.9mmhighx2.7mmflat-to-flathexandmetricthread.
25
Two-Stage: External Hex ENDOPORE® Hybrid
Theself-tappingEntegraExternalHexConnectionimplantsareavailableinthreediameters:3.25mm,4.0mmand4.75mm.Theimplantsarepackagedwithauniquenohandling,pre-mounteddeliverysystemandthepackageshavecolorcodedlabelsthatidentifytheirdiameters.Allimplantshaveasmooth,unthreadedcoronalregion(SCR)of1mm,andarepackagedwithalowprofilecoverscrew.
TheEntegraimplantsareavailablewiththefollowingsurfacetreatments;acid-washed(AE),hydroxylapatite(HA)ortitaniumplasmasprayed(TPS).Entegraimplantsof8mmand10mminlengthwithasurfacetreatmenthavethefirsttwocoronalthreadsuntreated.Implantsof13mm,15mmand18mminlengthhavethefirstthreecoronalthreadsuntreated.
3.5 mm diameter abutment platform
Theseimplantshavea3.5mmdiameterabutmentplatformwitha0.9mmhighx2.0mmflat-to-flathexandaUNFthread.Theimplantshavea3.25mmdiameterandarepackagedinredlabeledboxes(03M-range).
4.1 mm diameter abutment platform
Theseimplantshavea4.1mmdiameterabutmentplatformwitha0.7mmhighx2.7mmflat-to-flathexandametricthread.Theimplantsareavailablewitha3.25mmora4.00mmdiameterandarepackagedingreenlabeledboxes(03B-range).
5.0 mm diameter abutment platform
Theseimplantshavea5.0mmdiameterabutmentplatformwitha0.9mmhighx2.7mmflat-to-flathexandametricthread.Theimplantshavea4.75mmdiameterandarepackagedinturquoiselabeledboxes(03WB-range).
Entegra Implants with External Hex
26
ENTEGRATM Two-Stage: External Hex
Length
Platform
Diameter
Abutment Platform Ø 3.5 mm 3.25mm 8mm 03M-8Sx3.25AE3.25mm 10mm 03M-10Sx3.25AE3.25mm 13mm 03M-13Sx3.25AE
Abutment Platform Ø 4.1 mm 3.25mm 8mm 03B-8Sx3.25AE3.25mm 10mm 03B-10Sx3.25AE3.25mm 13mm 03B-13Sx3.25AE4.00mm 8mm 03B-8Sx4.0AE4.00mm 10mm 03B-10Sx4.0AE4.00mm 13mm 03B-13Sx4.0AE4.00mm 15mm 03B-15Sx4.0AE4.00mm 18mm 03B-18Sx4.0AE
Abutment Platform Ø 5.0 mm 4.75mm 8mm 03WB-8Sx4.75AE4.75mm 10mm 03WB-10Sx4.75AE4.75mm 13mm 03WB-13Sx4.75AE4.75mm 15mm 03WB-15Sx4.75AE4.75mm 18mm 03WB-18Sx4.75AE
Acid-Washed (AE) Diameter Length Item-No.
Allimplantsarepackagedwithalowprofilecoverscrew.
Length
Platform
Diameter
Abutment Platform Ø 3.5 mm 3.25mm 8mm 03M-8Sx3.25HA3.25mm 10mm 03M-10Sx3.25HA3.25mm 13mm 03M-13Sx3.25HA
Abutment Platform Ø 4.1 mm 3.25mm 8mm 03B-8Sx3.25HA3.25mm 10mm 03B-10Sx3.25HA3.25mm 13mm 03B-13Sx3.25HA4.00mm 8mm 03B-8Sx4.0HA4.00mm 10mm 03B-10Sx4.0HA4.00mm 13mm 03B-13Sx4.0HA4.00mm 15mm 03B-15Sx4.0HA4.00mm 18mm 03B-18Sx4.0HA
Abutment Platform Ø 5.0 mm 4.75mm 8mm 03WB-8Sx4.75HA4.75mm 10mm 03WB-10Sx4.75HA4.75mm 13mm 03WB-13Sx4.75HA4.75mm 15mm 03WB-15Sx4.75HA4.75mm 18mm 03WB-18Sx4.75HA
Hydroxylapatite (HA) Diameter Length Item-No.
27
Two-Stage: External Hex ENTEGRATM
Length
Platform
Diameter
Abutment Platform Ø 3.5 mm 3.25mm 8mm 03M-8Sx3.25TPS3.25mm 10mm 03M-10Sx3.25TPS3.25mm 13mm 03M-13Sx3.25TPS
Abutment Platform Ø 4.1 mm 3.25mm 8mm 03B-8Sx3.25TPS3.25mm 10mm 03B-10Sx3.25TPS3.25mm 13mm 03B-13Sx3.25TPS4.00mm 8mm 03B-8Sx4.0TPS4.00mm 10mm 03B-10Sx4.0TPS4.00mm 13mm 03B-13Sx4.0TPS4.00mm 15mm 03B-15Sx4.0TPS4.00mm 18mm 03B-18Sx4.0TPS
Abutment Platform Ø 5.0 mm 4.75mm 8mm 03WB-8Sx4.75TPS4.75mm 10mm 03WB-10Sx4.75TPS4.75mm 13mm 03WB-13Sx4.75TPS4.75mm 15mm 03WB-15Sx4.75TPS4.75mm 18mm 03WB-18Sx4.75TPS
Titanium Plasma Sprayed(TPS) Diameter Length Item-No.
Allimplantsarepackagedwithalowprofilecoverscrew.
28
ENTEGRATM Two-Stage: External Hex
Case Planning Chart
15° 25°
BridgeCrown
Impression Stage
Laboratory Processing
Final Restoration
One-and- Two-Stage
Flared Healing
Abutment
Straight Healing
Abutment
Flared Transfer
Coping Assembly
Straight Transfer
Coping Assembly
Flared Hexed
Abutment
Angled Hexed
Abutment
Angled Hexed
Abutment
Straight Hexed
Abutment
Hexed UCLA
Abutment
Non-Hexed UCLA
Abutment
29
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Case Planning Chart
Overdenture
Impression Stage
Laboratory Processing
Final Restoration
Straight Healing
Abutment
O-Ring
System
Dalla Bona
System
Second Surgery
Locator
System
Overdenture
System
30
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
Case Planning Chart
BarCrown OverdentureBridge
Impression Stage
Laboratory Processing
Final Restoration
O-RingBridge, Bar and Clip
Step 1
Step 2
Step 1
Step 2
Standard UMA System Abutment
UMA Healing Cap
Single Crown
SecondSurgery
31
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
3.5mm 3mm 3.5mm 02M-3HS3.5mm 5mm 3.5mm 02M-5HS3.5mm 7mm 3.5mm 02M-7HS
4.1mm 3mm 4.1mm 02B-3HS4.1mm 5mm 4.1mm 02B-5HS4.1mm 7mm 4.1mm 02B-7HS
5.0mm 3mm 5.0mm 02WB-3HS5.0mm 5mm 5.0mm 02WB-5HS5.0mm 7mm 5.0mm 02WB-7HS
3.5mm 4mm 4.5mm 02M-4H3.5mm 6.5mm 4.5mm 02M-6.5H
4.1mm 4mm 5.3mm 02B-4H4.1mm 6.5mm 5.3mm 02B-6.5H
5.0mm 4mm 6.8mm 02WB-4H5.0mm 6.5mm 6.8mm 02WB-6.5H
Crown and Bridge Restorations
Cover Screws Impl. Ø mm Item-No.
Cover Screw (replacement)Alowprofilecoverscrewispackagedwitheachimplant.
3.5mm 02M-CS4.1mm 02B-CS5.0mm 02WB-CS
Healing Abutments Impl. Ø mm Length Width Item-No.
Straight Healing AbutmentsThestraighthealingabutmentisusedinallsituationsexceptwhereanexpandedgingivalcuffisdesired.
Flared Healing AbutmentsTheuseofaflaredhealingabutmentallowsthegingivatohealaroundthisexpandedprofile,whereamorenaturalemergenceprofileispreferred.
Length
Width
Length
Width
Flared Healing
Abutment
Straight Healing
Abutment
32
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
Transfer Copings Impl. Ø mm Length Width Item-No.
Theshapeofthetransfercopingmatchestheshapeofthecorrespondinghealingabutmentandthisallowstheprofileofthegingivalcufftobeaccuratelyreproducedintheworkingmodel.
Straight Transfer CopingsForusewithstraighthealingabutments
Flared Transfer CopingsForusewithflaredhealingabutments
Transfer Coping Screw, longForoptionalusewithtransfercopings,whenan“opentray”techniqueisused
3.5mm 11mm 3.5mm 06M-CTCA/S3.5mm 16mm 3.5mm 06M-CTCA/SL
4.1mm 11mm 4.1mm 06B-CTCA/S4.1mm 16mm 4.1mm 06B-CTCA/SL
5.0mm 11mm 5.0mm 06WB-CTCA/S5.0mm 16mm 5.0mm 06WB-CTCA/SL
3.5mm 11mm 4.5mm 06M-CTCA/F
4.1mm 11mm 5.3mm 06B-CTCA/F4.1mm 16mm 5.3mm 06B-CTCA/FL
5.0mm 11mm 6.1mm 06WB-CTCA/F
3.5mm 16mm 06-TC/SL
4.1/mm 16mm 06B-TC/SL5.0mm
marking
marking
marking
marking
Ø 3.5
Straight Transfer Copings 11 mm Flared Transfer Copings 11 mm
Ø 4.1 Ø 5.0 Ø 3.5 Ø 4.1 Ø 5.0
Transfer Coping Screw for optional use 16 mm
Ø 3.5 Ø 4.1
Ø 5.0
marking marking
marking
Open Impression
Closed Impression
marking marking
33
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Implant Analogs Impl. Ø mm Length Qty. Item-No.
Implant Analogs Material:Aluminum
Implant AnalogsMaterial:StainlessSteel
3.5mm 9mm 1 06M-IA/13.5mm 9mm 5 06M-IA
4.1mm 9mm 1 06B-IA/14.1mm 9mm 5 06B-IA
5.0mm 9mm 1 06WB-IA/15.0mm 9mm 5 06WB-IA
3.5mm 9mm 1 06M-PIA3.5mm 9mm 5 06M-PIA/5
4.1mm 9mm 1 06B-PIA4.1mm 9mm 5 06B-PIA/5
5.0mm 9mm 1 06WB-PIA5.0mm 9mm 5 06WB-PIA/5
Retaining Screws Impl. Ø mm Item-No.
3.5mm 05-2RS
4.1/mm 05B-2RS/G5.0mm
3.5mm 05M-2RS/G
4.1/mm 05B-2RS/G5.0mm
ForusewithhexedandUCLAabutments
Replacement ScrewMaterial:TitaniumAlloy
Replacement ScrewMaterial:GoldAlloy
Aluminum Stainless Steel
Ø 3.5 Ø 4.1 Ø 5.0 Ø 3.5 Ø 4.1 Ø 5.0
Allabutmentsarepackagedwithatitaniumretainingscrew.
34
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
Hexed Abutments Impl. Ø mm Length Collar Item-No.
Straight Hexed Abutments RetainingscrewincludedThestraighthexedabutmenthasaparallelsidedtransgingivalcollar.Theseabutmentsareavailableinbothregular(grooved– FS)andthickwall(notgrooved–FN)versions.
Theseabutmentsareusedforcementretainedcrownorbridgerestorations.
3.5mm 7mm 1.5mm 05M-7FS3.5mm 7mm 1.5mm 05M-7FN3.5mm 9mm 3.5mm 05M-9FN
4.1mm 7mm 1.5mm 05B-7FS4.1mm 7mm 1.5mm 05B-7FN4.1mm 9mm 3.5mm 05B-9FS4.1mm 9mm 3.5mm 05B-9FN4.1mm 11mm 5.5mm 05B-11FS4.1mm 11mm 5.5mm 05B-11FN
5.0mm 7mm 1.5mm 05WB-7FS5.0mm 7mm 1.5mm 05WB-7FN5.0mm 9mm 3.5mm 05WB-9FS5.0mm 9mm 3.5mm 05WB-9FN5.0mm 11mm 5.5mm 05WB-11FS5.0mm 11mm 5.5mm 05WB-11FN
Flared Hexed Abutments RetainingscrewincludedTheflaredhexedabutmentisdesignedforrestorationsrequiringanaturalemergenceprofile.Theseabutmentsareavailableinbothregular(grooved–UF)andthickwall(notgrooved–UN)versions.
3.5mm 8.5mm 2mm 05M-8.5UN3.5mm 9mm 2mm 05M-9UF
4.1mm 8.5mm 2mm 05B-8.5UN4.1mm 10mm 2mm 05B-10UF4.1mm 11.5mm 3.5mm 05B-11.5UN
5.0mm 8.5mm 1.5mm 05WB-8.5UN5.0mm 8mm 1.5mm 05WB-8UF5.0mm 10.5mm 3.5mm 05WB-10.5UN
Length
Collar
Length
Collar
Length
Collar
Length
Collar
UN UF
FN FS
35
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Hexed Abutments Impl. Ø mm Length Angle Item-No.
3.5mm 11mm 15˚ 05M-15FA3.5mm 11mm 25˚ 05M-25FA
4.1mm 11mm 15˚ 05B-15FA4.1mm 11mm 25˚ 05B-25FA
5.0mm 11mm 15˚ 05WB-15FA5.0mm 11mm 25˚ 05WB-25FA
Angled Hexed AbutmentsRetainingscrewincludedAngledabutmentscompensateforlargedivergencesinimplantalignment.AngledguidepinsareavailableintheProstheticInstrumentationsectionofthiscatalog,pages43–44.
15°
Temporary Titanium Abutments Impl. Ø mm Item-No.
Temporary AbutmentsRetainingscrewincluded
HexedTemporaryAbutment
Non-HexedTemporaryAbutment
3.5mm 05M-TEMP/H
4.1mm 05B-TEMP/H
5.0mm 05WB-TEMP/H
3.5mm 05M-TEMP
4.1mm 05B-TEMP
5.0mm 05WB-TEMP
25°
36
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
Crown and Bridge Restorations
UCLA Abutments Impl. Ø mm Item-No.
UCLA Gold Base Abutments Ceramic AlloyRetainingscrewincluded
Hexed
Non-Hexed
UCLA Gold Base AbutmentsNon-Ceramic AlloyRetainingscrewincluded
HexedGoldBaseUCLAAbutment
Non-HexedGoldBaseUCLAAbutment
3.5mm 06M-UCLA/H/G4.1mm 06B-UCLA/H/G5.0mm 06WB-UCLA/H/G
3.5mm 06M-UCLA/G4.1mm 06B-UCLA/G5.0mm 06WB-UCLA/G
3.5mm 06M-UCLA/H/GNC4.1mm 06B-UCLA/H/GNC5.0mm 06WB-UCLA/H/GNC
3.5mm 06M-UCLA/GNC4.1mm 06B-UCLA/GNC5.0mm 06WB-UCLA/GNC
ImportantThemeltingrangeis1400–1490˚C(2550–2710˚F),refertopackageinstructionsforfurtherdetails.
ImportantThemeltingrangeis1232–1260˚C(2250–2300˚F),refertopackageinstructionsforfurtherdetails.
Non-HexedHexed
Non-HexedHexed
UCLAabutmentsprovideafoundationtowhichwaxcanbeaddedtoshapeascrew-retainedcrownorbridgeoracustomabutment.SeetheProstheticInstrumentationsectionforthelappingtoolusedtopolishthecastsurfacethatwillmatewiththeimplant.Areamerisalsoavailabletocleanouttheretainingscrewholeinthecasting.Goldbaseabutmentshave
machinedsurfacesandwillnotrequirefinishingwiththesetools.HexedUCLAabutmentsshouldbeusedforcustomabutmentsandforsupportingcrownsastheywillresisttherotationalforcesassociatedwithsingletoothrestorations.Non-hexedUCLAabutmentsshouldbeusedforsupportingscrewretainedbridges.
UCLA Plastic Abutments Retainingscrewincluded
Hexed,greenHexed,yellowHexed,blue
Non-Hexed,whiteNon-Hexed,whiteNon-Hexed,yellow
3.5mm 06M-UCLA/H4.1mm 06B-UCLA/H5.0mm 06WB-UCLA/H
3.5mm 06M-UCLA4.1mm 06B-UCLA5.0mm 06WB-UCLA
Hexed Non-Hexed
37
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Overdenture Restorations
O-Ring Abutment System (ORS) Impl. Ø mm Collar Length Item-No.
O-Ring Abutment SystemTheO-Ringabutmentsystemcanaccommodateupto5degreesofdivergencebetweenimplants.
EachO-RingSystemincludesatitaniummaleabutmentandanORSlabkitwhichincludesabrassabutmentanalog,metalhousing,3redO-Ringsand3whiteO-Rings.
Note: TheredO-Ringisusedforlaboratoryset-upandthewhiteO-Ringisusedforthefinishedoverdenture.
O-Ring Accessories Item-No.
3.5mm 1mm 4mm 04M-1ORS3.5mm 2mm 5mm 04M-2ORS3.5mm 3mm 6mm 04M-3ORS3.5mm 4mm 7mm 04M-4ORS3.5mm 5mm 8mm 04M-5ORS
4.1mm 1mm 4mm 04B-1ORS4.1mm 2mm 5mm 04B-2ORS4.1mm 3mm 6mm 04B-3ORS4.1mm 4mm 7mm 04B-4ORS4.1mm 5mm 8mm 04B-5ORS4.1mm 6mm 9mm 04B-6ORS4.1mm 7mm 10mm 04B-7ORS
5.0mm 1mm 4mm 04WB-1ORS5.0mm 2mm 5mm 04WB-2ORS5.0mm 3mm 6mm 04WB-3ORS5.0mm 4mm 7mm 04WB-4ORS5.0mm 5mm 8mm 04WB-5ORS5.0mm 6mm 9mm 04WB-6ORS
LengthCollar
TheLocatorabutmentisanattachmentwithaself-aligningfeature.Thisfeaturewillaidpatientsinseatingtheirdentureandeliminateadditionalwearfromimproperseating.
WiththeLocator’sminimalverticalheight,itisidealwhereinterocclusalspaceislimited.Thisabutmentcanalsoaccommodateupto40°betweenimplants.
LOCATOR® Abutments Impl. Ø Collar Item-No.
3.5mm 1mm 08-88513.5mm 2mm 08-88523.5mm 3mm 08-88533.5mm 4mm 08-88543.5mm 5mm 08-88554.1mm 0.73mm 08-8681*4.1mm 2mm 08-8682*4.1mm 3mm 08-8683*4.1mm 4mm 08-8684*4.1mm 5mm 08-8685*4.1mm 6mm 08-8696*5.0mm 1mm 08-86915.0mm 2mm 08-86925.0mm 3mm 08-86935.0mm 4mm 08-86945.0mm 5mm 08-8695
Pleaserefertopages11or20forLocatorAttachments.
*NotavailableintheUSA.
O-Ring Lab Kit
Metal Housing
White O-Rings10pack
06-ORS
07-0044
06-O/ORS
38
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
Dalla Bona Abutment System Impl. Ø mm Collar Length Item-No.
Dalla Bona Abutment SystemTheDallaBonaabutmentisaball&sockettypeconnector.Itssphericaldesignallowsupto15degreesdivergencebetweentheabutments.
EachDallaBonaSystemincludesatitaniummaleabutment,abrassabutmentanalog,atitaniumfemalewithaPVCringandaspacer.
Dalla Bona Plus Accessories Item-No.
Dalla Bona PlusKeepingthesamebenefitsastheDallaBonaSystem,theDallaBonaPlusfemaleattachmentisagoldinsertthatcanbeeasilyreplacedandadjustedwithDallaBonaPlusActivating/DeactivatingTool.
Dalla Bona Plus Activating/Deactivating ToolAninstrumentusedtoincreaseandreducetheretentionofanattachment.
Dalla Bona Lab KitIncludesabrassabutmentanalog,atitaniumfemalewithaPVCringandaspacer.
Dalla Bona Activating Tool Aninstrumentusedtoincreasetheretentionofanattachment.
Dalla Bona Deactivating Tool Aninstrumentusedtoreducetheretentionofanattachment.
07-0482
07-0489
07-1012
07-1017
07-1018
Length
3.5mm 1mm 4mm 04M-1DB3.5mm 2mm 5mm 04M-2DB3.5mm 3mm 6mm 04M-3DB3.5mm 4mm 7mm 04M-4DB3.5mm 5mm 8mm 04M-5DB3.5mm 6mm 9mm 04M-6DB3.5mm 7mm 10mm 04M-7DB
4.1mm 1mm 4mm 04B-1DB4.1mm 2mm 5mm 04B-2DB4.1mm 3mm 6mm 04B-3DB4.1mm 4mm 7mm 04B-4DB4.1mm 5mm 8mm 04B-5DB4.1mm 6mm 9mm 04B-6DB4.1mm 7mm 10mm 04B-7DB
5.0mm 1mm 4mm 04WB-1DB5.0mm 2mm 5mm 04WB-2DB5.0mm 3mm 6mm 04WB-3DB5.0mm 4mm 7mm 04WB-4DB5.0mm 5mm 8mm 04WB-5DB5.0mm 6mm 9mm 04WB-6DB5.0mm 7mm 10mm 04WB-7DB
Collar
Dalla Bona Accessories Item-No.
39
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Overdenture Abutment System Impl. Ø mm Collar Length Item-No.
Overdenture AbutmentsTheOverdentureabutmentoffersasimplesolutionforstabilizinganoverdenturewithimplants.AnO-RingembeddedintheoverdentureacrylicengagestheundercutoftheOverdentureabutment.Alternatively,aninsertofpolysiloxanematerialwithintheoverdentureacrylicengagestheundercutoftheoverdentureabutment.Properpreparationwitheitherarrangementwillprovideresilienceintheconnection.
3.5mm 4mm 6.5mm 04M-4OA3.5mm 6mm 8.5mm 04M-6OA
4.1mm 4mm 6.5mm 04B-4OA4.1mm 6mm 8.5mm 04B-6OA4.1mm 8.5mm 11mm 04B-8.5OA
5.0mm 4mm 6.5mm 04WB-4OA5.0mm 6mm 8.5mm 04WB-6OA5.0mm 8.5mm 11mm 04WB-8.5OA
Overdenture Accessories Item-No.
Forusewithoverdentureabutments
Overdenture Abutment Analog3pack
O-Ring Set10pack
06-OAA
06-O/OA
Collar
40
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
UMA System AbutmentsTheUMA(UniversalModificationAbutment)systemisusedforscrewretainedrestorationswhereitisdesiredtohavethepointsofattachmentsuperiortothesofttissue.WherethereisinsufficientclearancetouseaUMAorwhenasub-gingivalseparationisdesired,aUCLAabutmentcanbeusedtoachieveseparationoftherestorationattheimplantlevel.
TheUMAisatransmucosalcollarthatshouldbesecuredtotheimplantwith30Ncmoftorque.TheUMAscrewusedtosecuretherestorationtotheabutmentispackagedwitheachUMAplasticcoping.A0.05“hexdriverisusedtosecurethescrewwhichshouldonlybetightenedto20Ncm.
Standard UMA System AbutmentTheupperdiameterforallUMASystem
Abutmentsis3.85mm.
UMA System Impl. Ø mm Collar Item-No.
3.5mm 3.5mm 02M-3.5UMA3.5mm 4.5mm 02M-4.5UMA3.5mm 5.5mm 02M-5.5UMA3.5mm 6.5mm 02M-6.5UMA
4.1mm 2.5mm 02B-2.5UMA4.1mm 3.0mm 02B-3.0UMA4.1mm 4.0mm 02B-4.0UMA4.1mm 5.0mm 02B-5.0UMA4.1mm 6.0mm 02B-6.0UMA4.1mm 7.0mm 02B-7.0UMA4.1mm 8.0mm 02B-8.0UMA
5.0mm 3.5mm 02WB-3.5UMA5.0mm 4.5mm 02WB-4.5UMA5.0mm 5.5mm 02WB-5.5UMA5.0mm 6.5mm 02WB-6.5UMA
UMA Healing Cap Item-No.
UMA Healing Cap2mm
07-2120
UMA Transfer Copings Item-No.
UMA Hexed Transfer CopingSingletoothopentray
UMA Guide PinFor07-0090
UMA Non-Hexed Transfer Coping Bridge
07-0090
07-0062
07-0080
Collar
41
Two-Stage: External Hex ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
UMA Analogs Item-No.
Brass
Stainless Steel UMAretainingscrewincluded
07-0015
07-0162
UMA Copings Item-No.
UMA Temporary Non-Hexed Coping UMAretainingscrewincluded
UMA Hexed Plastic CopingUMAretainingscrewincluded
UMA Non-Hexed Plastic CopingUMAretainingscrewincluded
UMA Non-Hexed Gold CopingUMAretainingscrewincluded
07-0352
07-0202
07-0252
07-0252/G
Brass Stainless Steel
UMA Replacement Components Item-No.
UMA Non-Hexed Plastic Coping ForBar
UMA Retaining Screw
Gold Plated Bar ClipCMRider
07-0270
07-0052
07-0120
UMA Bar Kit Item-No.
UMA Bar KitIncludes4bars,aspacerbar,4retainingscrews,4plasticcylinders,and4goldplatedclips
07-5540
Gold Plated
Bar Clip
UMA Non-Hexed
Gold Coping
UMA O-Ring System Item-No.
UMA O-Ring System EachabutmentispackagedwithanORSlabkitthatincludesabrassabutmentanalog,metalhousing,3redO-Ringsand3whiteO-Rings.
07-4400
UMA Hexed
Plastic Coping
UMA Non-Hexed
Plastic Coping
UMA Non-Hexed
Plastic Coping
UMA Temporary
Non-Hexed Coping
UMA
Retaining Srew
NoteTheredO-Ringisusedforlaboratoryset-upandthewhiteO-Ringisusedforthefinishedoverdenture.
42
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Two-Stage: External Hex
13 mm
Prosthetic Instrumentation
Item-No.
Driver TipsFitDriverHousingandTorqueWrenches
0.05“ Hex Tip
0.05“ Hex Tip – Short
UMA Abutment Driver
ORS and Dalla Bona Abutment Driver
06-TWHT
06-TWHTS
07-1150
07-0140
18 mm
9 mm
Hex Drivers, 0.05“Extrashort,9mm
Short,13mm
Long,18mm
06-HDXS
06-HDS
06-HDL
extra short short long
Driver Housing
Driver Extension
07-0190
07-0195
Driver Housing Driver Extension
12.5 mm
Hex Tip
6.5 mm
Hex Tip short UMA Abutment
Driver
ORS and Dalla
Bona Abutment
Driver
30 Ncm Torque Wrench
20 Ncm Torque WrenchForusewithUMASystem
Ncm–Newtoncentimeters
06-TW30
06-TW20
43
Prosthetic ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Latch Driver0.05“HexLatchTypeDriver
07-0125
UMA Friction Grip DriverFrictiondriverforUMAnon-hexedtransfercopingandUMAO-RingAbutment
07-0004
Guide PinForangledabutmentselection15°angled
25°angled
06-15AAGP
06-25AAGP
Reamer ForusewithUMAabutmentcastings
ForusewithUCLAabutmentcastings
07-0150
06-REM
Lapping Tool with guide pin ForusewithUMAandUCLAabutmentcastingsandallplatforms
07-0155WP
Waxing Sleeve 06-WS
Prosthetic Instrumentation Item-No.
15° 25°44
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic
Prosthetic Procedures
ThefollowingprostheticproceduresareexamplesofthemostfrequentlyappliedprostheticrestorationsfortheEndopore,EndoporeHybridandEntegraDentalImplantSystems.Thecasepresentationsareshownwithexternalhexcomponents,howevertheprincipalconceptsarealsousedforinternalhexcomponents.
Theproceduresdiscussedareonlyguidelines.Manyalternativesexistforthecompletionofasuccessfulimplantrestoration.
Case Presentations
Single Tooth RestorationsSingle,CementedUnitUsingHexedTitaniumAbutmentSingle,ScrewRetainedUnitHexedUCLAAbutment
Multiple Tooth RestorationsMultiple,CementedUnitsUsingHexedTitaniumAbutmentsMultiple,ScrewRetainedUnitsUsingNon-HexedUCLAAbutmentsMultiple,ScrewRetainedUnitsUsingNon-HexedUMAAbutments
Overdenture RestorationsOverdenturewithScrewRetainedBarUsingNon-HexedUMAAbutmentsOverdentureUsingO-RingSystemAbutmentsOverdentureUsingDallaBonaAbutmentsOverdentureUsingOverdentureAbutments
Note
Theprostheticrestorationofdentalimplantsrequiresspecialtraining.Therestorativecliniciandetermineswhetheraproductissuitablefortheparticularapplication.Improperrestorationchoiceortechniquecanresultinimplantand/orrestorationfailure.Forprostheticcourses,contactInnova’sDepartmentofContinuingEducationat800.718.5157orseminars@innovalife.com.
45
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
1
2
3
4
5
6
78 9
1011
12
13
14
15
16LR
Maxilla
46
Exposetheimplantbyremovingtheflaredhealingabutmentwitha0.05“hexdriverandrinsewithanair-watersyringe.Note: Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
Engagethehexportionoftheflaredtransfercopingontothehexportionoftheimplantusinga0.05“hexdriverandtightenwithfingerpressure(leftgraphic).Note: ItisimportanttotakeaperiapicalX-raytoverifythefitbetweenthetransfercopingandtheimplant(rightgraphic).Note:Alongtransfercopingscrewisavailableforan“opentray”technique.
Block-outthetransfercopinghexopeningwithacottonpelletorsoftwaxtofacilitateaccessaftertheimpression.Injectimpressionmaterialaroundthetransfercoping(leftgraphic).Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpressionremovethetransfercopingandattachittotheimplantanalog.Placethetransfercopingbackintotheimpression,aligningtheflatsurfaceofthetransfercopingwiththeflatsurfaceintheimpression(rightgraphic).Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarchandaproperbiteregistration.Note:Aftertheimpressionhasbeentaken,replacethehealingabutmentoruseatemporarycrownfabricatedchairsideorsuppliedbythelaboratory.
Single, Cemented UnitUsing Hexed Titanium Abutment
Temporary crown:Shortenthetemporaryabutmenttoappropriateocclusalscheme.Attachthehexedtemporarytitaniumabutmentontotheimplantandtorqueto20N/cm.
Attachthecrownformorshapetheresintothetemporaryabutmentusingself-curingresin.Allowforsetting,removeandtrimacrylicaccess.
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
47
Removethetransfercopingandplacetheflaredhexedtitaniumabutmentontotheimplantanaloginthestonemodel.Thetitaniumabutmentcanbeshortenedandmodifiedinpreparationforthecementedcrown.Thetitaniumabutmentmarginsmaybepreparedsubgingival.Tofacilitatetheprocess,thetitaniumabutmentcanberemovedandmodifiedasdesiredbyattachingittoanextraimplantanalog(leftgraphic).Note:Thicknessonthetitaniumabutmenttoprotectthehexaccesshole.
Laboratory Steps
Clinical Steps
Stone Master Model:Softtissuematerialisinjectedaroundthetransfercopingbeforepouringthestonemastermodel.Ifrequestedbytheclinicianthelaboratorycancreateatemporarycrownusingatemporaryabutment.
Waxacopingoverthepreparedtitaniumabutment.Castthecopinginpreciousorsemipreciousceramicalloy.Finishthecopingandseatpassivelyontotheabutment.
Applyporcelainorotherveneermaterialandreturnthecrowntotheclinician.Amarkcanbeplacedatthebuccalsurfaceofthetitaniumabutmenttofacilitatetheorientationforthedentist.
Removethehealingabutmentortemporarycrown.Insertthetitaniumabutmentwitha0.05“hexdrivertipandtightenwithfingerpressure.TakeanX-ray.Torqueto30N/cm.Retighten in 10 minutes.Try-inthecrown,evaluateocclusionandesthetics.Block-outthescrewaccessholewithacottonpelletandcementthefinalsingleunitontothetitaniumabutment.Equilibrateocclusionasnecessary.PatientFollow-Up:Afterreceivingthecrown,thepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
48
1
2
3
4
5
6
78 9
1011
12
13
14
15
16LR
Maxilla
Exposetheimplantbyremovingtheflaredhealingabutmentwitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
Engagethehexportionoftheflaredtransfercopingontothehexportionoftheimplantusinga0.05“hexdriverandtightenwithfingerpressure(leftgraphic).Note: ItisimportanttotakeaperiapicalX-raytoverifythefitbetweenthetransfercopingandtheimplant(rightgraphic).Note:Alongtransfercopingscrewisavailableforan“opentray”technique.
Block-outthetransfercopinghexopeningwithacottonpelletorsoftwaxtofacilitateaccessaftertheimpression.Injectimpressionmaterialaroundthetransfercoping(leftgraphic).Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpressionremovethetransfercopingandattachittotheimplantanalog.Placethetransfercopingbackintotheimpression,aligningtheflatsurfaceofthetransfercopingwiththeflatsurfaceintheimpression(rightgraphic).Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarchandaproperbiteregistration.Note:Aftertheimpressionhasbeentaken,replacethehealingabutmentoruseatemporarycrownfabricatedchairsideorsuppliedbythelaboratory.
Single, Screw Retained UnitUsing Hexed UCLA Abutment
Temporary crown:Shortenthetemporaryabutmenttoappropriateocclusalscheme.Attachthehexedtemporarytitaniumabutmentontotheimplantandtorqueto20N/cm.
Attachthecrownformorshapetheresintothetemporaryabutmentusingself-curingresin.Allowforsetting,removeandtrimacrylicaccess.
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
49
Laboratory Steps
Clinical Steps
Stone Master Model:Softtissuematerialisinjectedaroundthetransfercopingbeforepouringthestonemastermodel.Ifrequestedbytheclinicianthelaboratorycancreateatemporarycrownusingatemporaryabutment.
RemovethetransfercopingandattachthehexedgoldbaseUCLAabutmenttotheanaloginthestonemodelusingtheretainingscrew(leftgraphic).ShortenthehexedUCLAabutmentasnecessaryforascrewretainedcrown.Note: ThehexedUCLAabutmentisrecommendedforscrewretainedsinglecrownstoprovideanti-rotation.UCLAabutmentsareavailablewitheitheragoldorplasticbase.The machined gold-based surface provides a more accurate fit than a cast plastic component.
ContourwaxaroundthehexedUCLAabutmentasdesired.Sprue,invest,castandfinishthehexedUCLAabutmentwithanaccesshole.Note:WhenusingoneofInnova’sgoldbaseUCLAabutmentsfollowthecastingandprocessingrecommendationssuppliedwiththeabutment.
Applyporcelainorotherveneermaterialwhilemaintainingtheaccessholeandreturntotheclinician.
Removethehealingabutmentortemporarycrown.Insertthecrownbyengagingtheretainingscrew(rightgraphic)witha0.05“hexdrivertipandtightenwithfingerpressure.Takeanx-ray.Torqueto30N/cm.Retighten in 10 minutes.Placeacottonpelletinthescrewaccessopeningbeforesealingwithacompositeresin.Equilibratetheocclusionasnecessary.PatientFollow-Up:Afterreceivingthecrown,thepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
50
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
Engagethehexportionofthestraighttransfercopingsontothehexportionoftheimplantsusinga0.05“hexdriverandtightenwithfingerpressure(leftgraphic).Note:Itisimportanttotakeaperiapicalx-raytoverifythefitbetweenthetransfercopingsandtheimplants(rightgraphic).Alongtransfercopingscrewisoptionalforan“opentray”technique.
Blocks-outthetransfercopinghexopeningswithcottonpelletorsoftwaxtofacilitateaccessaftertheimpression.Injectimpressionmaterialaroundthetransfercopings(leftgraphic).Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpressionremovethetransfercopingsandattachthemtotheimplantanalogs.Placethetransfercopingsbackintotheimpression,aligningtheflatsurfaceofthetransfercopingwiththeflatsurfaceintheimpression(rightgraphic).Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarchandaproperbiteregistration.Note:Aftertheimpressionhasbeentaken,replacethehealingabutmentsoruseatemporarycrownfabricatedchairsideorsuppliedbythelaboratory.
Multiple, Cemented UnitsUsing Hexed Titanium Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
51
Laboratory Steps
Clinical Steps
Stone Master Model:Softtissuematerialisinjectedaroundthetransfercopingsbeforepouringthestonemastermodel.Ifrequestedbytheclinicianthelaboratorycancreateanon-hexedtemporarybridgeusingtemporaryabutments.
Removethetransfercopingsandplacethestraighthexedabutmentsontotheimplantanalogs.Thetitaniumabutmentscanbeshortenedandmodifiedinpreparationforthecementedbridge.Tofacilitatetheprocess,thetitaniumabutmentsmayberemovedandmodifiedasdesiredbyattachingthemtoextraimplantanalogs(leftgraphic).Note:Careshouldbetakenintheselectionofabutmentsaseachimplantdiameterusesamatchingabutmentwiththesamediameter.Itisimportanttoleaveenoughheightandthicknessontheabutmentstoensurehexengagement.
Waxthecopingsoverthepreparedabutments.Sprue,invest,castandfinishtheframeworkfortheceramics.Finishtheframeworkandseatovertheabutments.An intraoral try-in is recommended for passive fit verification before applying ceramics.Aresinjigmaybefabricatedtoaidtheclinicianwiththeorientationofthepreparedabutmentsoralternativelybymarkingthebuccalareaoftheabutments.
Applyporcelainorotherveneermaterialtothebridgeframework.Thefinalbridgeissentbacktotheclinician.
Removethehealingabutmentsortemporarybridge.Inserttheabutmentswitha0.05“hexdrivertipandtightenwithfingerpressure.TakeanX-ray.Torqueto30N/cm.Retighten in 10 minutes.Try-inthebridge,evaluateandadjustocclusionasnecessary.Block-outthescrewaccessholeswithcottonpelletsbeforecementingthebridgeintoplace.Equilibrateocclusionasnecessary.PatientFollow-Up:Afterreceivingthefinalrestorationthepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
52
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
Engagethehexportionofthetransfercopingsontothehexportionoftheimplantsusinga0.05“hexdriverandtightenwithfingerpressure(leftgraphic).Note:Itisimportanttotakeaperiapicalx-raytoverifythefitbetweenthetransfercopingsandtheimplants(rightgraphic).Alongtransfercopingscrewisoptionalforan“opentray”technique.
Block-outthetransfercopinghexopeningwithcottonpelletsorsoftwaxtofacilitateaccessaftertheimpression.Injectimpressionmaterialaroundthetransfercopings(leftgraphic).Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpressionremovethetransfercopingsandattachthemtotheimplantanalogs.Placethetransfercopingsbackintotheimpression,aligningtheflatsurfaceofthetransfercopingswiththeflatsurfaceintheimpression(rightgraphic).Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarchandaproperbiteregistration.Note:Aftertheimpressionhasbeentaken,replacethehealingabutmentsoruseatemporarybridgefabricatedchairsideorsuppliedbythelaboratory.
Multiple, Screw Retained UnitsUsing Non-Hexed UCLA Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
53
Laboratory Steps
Clinical Steps
Stone Master Model:Softtissuematerialisinjectedaroundthetransfercopingsbeforepouringthestonemastermodel.Ifrequestedbytheclinician,thelaboratorycancreateatemporarybridgeusingthetemporaryabutments.
Removethetransfercopingsandscrewthenon-hexedgoldbaseUCLAabutmentsintothestonemodelusingtheretainingscrews.Shortenthenon-hexedUCLAabutmentsasnecessary.Note:Thenon-hexedUCLAabutmentsarerecommendedforbridgerestorationstofacilitatethepathofinsertion.UCLAabutmentsareavailablewitheitheragoldorplasticbase.The machined gold-based surface provides a more accurate fit than a cast plastic component.
Contourwaxaroundthenon-hexedUCLAabutmentsasdesired.Sprue,invest,castandfinishthemetalsubstructurewithaccessholes.Applyporcelainorotherveneermaterial.Anintraoraltry-inisrecommendedforpassivefitverification.Note:WhenusingoneofInnova’sgoldbaseUCLAabutmentsfollowthecastingandprocessingrecommendationssuppliedwiththeabutment.Porcelaincanbefireddirectlytothegoldbase.
Thefinalbridgeissentbacktotheclinician.
Removethehealingabutmentsorthetemporarybridge.Screwthefinalrestorationintoplacewitha0.05“hexdrivertipandtightenwithfingerpressure.TakeanX-ray.Torqueto30N/cm.Retighten in 10 minutes.Placecottonpelletsinthescrewaccessopeningsbeforesealingwithcompositeresin.Equilibrateocclusion.PatientFollow-Up:Afterreceivingthefinalrestorationthepatientisgivenoralhygieneinstructions.Recallinstructionsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
54
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
MeasurethetissueabovetheimplantstodeterminetheappropriateheightoftheUMAabutments.TheUMAabutmentsshouldbeslightlysubgingivalforesthetics.InserttheselectedUMAabutmentswithanUMAabutmentdriverandtorqueto30N/cm(rightgraphic).Note:Itisimportanttotakeaperiapicalx-raytoverifythefitbetweentheUMAabutmentandtheimplant.
EngagetheUMAtransfercopingsontotheUMAabutmentsandtightenwithlight finger pressure,usingtheUMAfrictiongripdriver.
InjectimpressionmaterialaroundtheUMAtransfercopings.Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
AftertakingtheimpressionremovetheUMAtransfercopingsandattachthemtotheUMAanalogs.PlacetheUMAtransfercopingsbackintotheimpression.Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarchandproperbiteregistration.Note:PlacetheUMAhealingcapsontotheUMAabutmentswitha0.05”hexdriverwithfingerpressureonly.
Multiple, Screw Retained UnitsUsing Non-Hexed UMA Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
55
Laboratory Steps
Clinical Steps
Stone Master Model:SofttissuematerialisinjectedaroundtheUMAtransfercopingsbeforepouringthestonemastermodel.
Engagethenon-hexedUMAplasticorgoldbridgecopingstotheUMAanalogsinthestonemastermodelwitha0.05“hexdriver.Note:Thenon-hexedUMAcopingsarerecommendedforbridgerestorationstofacilitatethepathofinsertion.
ContourthewaxaroundtheUMAcopings.Sprue,invest,castandtrimtheUMAcopingframeworkmaintainingtheaccessholes.Note:WhenusingagoldbaseUMAfollowthecastingandprocessingrecommendationssuppliedwiththecoping.Porcelaincanbefireddirectlytothegoldbase.Anintraoraltry-inisrecommendedforpassivefitverificationbeforeapplyingtheceramics.
Applyporcelainorotherveneermaterialsandmaintaintheaccessholes.Sendthefinalrestorationtotheclinician.
Applyporcelainorotherveneermaterialsandmaintaintheaccessholes.Sendthefinalrestorationtotheclinician.RemovetheUMAhealingcapsorthetemporarybridge.Screwthefinalrestorationintoplacewitha0.05“hexdrivertipandtightenwithfingerpressure.Takeanx-ray.Torqueto20N/cm.Retighten in 10 minutes.Block-outthescrewaccessholesbeforesealingwithcompositeresin.Equilibrateocclusionasnecessary.PatientFollow-Up:Afterreceivingthefinalrestorationthepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
56
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
MeasurethetissueabovetheimplantstodeterminetheappropriateheightoftheUMAabutments.TheUMAabutmentsshouldbeslightlysubgingivalforesthetics.InserttheselectedUMAabutmentswithanUMAabutmentdriverandtorqueto30N/cm(rightgraphic).Takeanx-ray.
EngagetheUMAtransfercopingsontotheUMAabutmentsandtightenwithlight finger pressure,usingtheUMAfrictiongripdriver.
ApplyimpressionmaterialaroundtheUMAtransfercopings(leftgraphic).Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
AftertakingtheimpressionremovetheUMAtransfercopingsandattachthemtotheUMAanalogs.PlacetheUMAtransfercopingsbackintotheimpression.Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarch.Note:PlacetheUMAhealingcapsontotheUMAabutmentswitha0.05“hexdriverwithfingerpressureonly.
Overdenture with Screw Retained BarUsing Non-Hexed UMA Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
Oncethecastbarisavailablefromthelaboratory,itspassivefitshouldbeconfirmedthroughpatienttry-inandx-ray.
57
Laboratory Steps
Clinical Steps
Stone Master Model:Thetechnicianpoursthestonemastermodel.Abaseplateandbiterimarefabricatedandsenttotheclinicianforintraoralregistration.Afterthebiteregistrationisreturned,thecastsaremountedandadenturetoothsetupiscompletedandreturnedforanintraoraltry-in.Oncethetry-inisreturnedtothelaboratory,asiliconmatrixisfabricatedtoaidintheproperbarpositioning.
Engagethenon-hexedUMAplasticorgoldbridgecopingstotheUMAanalogsinthestonemastermodelwitha0.05”hexdriver.
UsethesiliconmatrixtodeterminethebarpositionbetweentheUMAbridgecopings.Thebarshouldbepositionedapproximately1mmabovetheridgeforhygienepurposes.
Sprue,invest,castandfinishthebarframework.Thebarshouldbecastwithhardpreciousorsemipreciousalloy.(Donotusenon-preciousalloys).Uponcompletionsendthebarframeworktotheclinicianforanintraoraltry-intoverifypassivefit.Aftertheregistrationisreturned,placethespacerandclipoverthebar.Block-outthebargingivallywithplasterandathincopingoflatexmaterialbeforethepolymerizationprocessandfinishtheacrylic.Note:Thefinalbarandoverdenturearereturnedtotheclinicianforinsertion.
RemovetheUMAhealingabutmentsandscrewthebarintoplacewitha0.05”hexdriverandtightenwithfingerpressure.TakeanX-ray.Torqueto20N/cm.Retighten in 10 minutes.Placefinishedprosthesisoverbarandequilibrateifnecessary.PatientFollow-Up:Afterreceivingtheoverdenture,thepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
58
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
MeasurethetissuedepthabovetheimplantstodeterminetheappropriateheightoftheO-Ringmaleabutmentstobeused.Theshoulderoftheabutmentsshouldbeslightlyabovethetissue(approximately2mm).PlacetheO-Ringabutmentsontotheimplantswiththeabutmentdriverandtorqueto30N/cm(leftgraphic).Note:TightentheO-Ringabutmentswithfingerpressureonlyifthehealingabutmentswillbere-insertedaftertheimpressionstage.
InjectaimpressionmaterialaroundtheO-Ringabutments.Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpression,insertO-Ringanalogsintotheimpression.Theanalogsmaybesecuredwithwaxoradhesive.Sendtheimpressiontothelaboratoryandincludethehousingsandredprocessingringsforfabricationofthemastercast.Note:KeepthewhiteO-Ringsforfinalinsertionorsendtothelaboratoryforcompletion.Theexistingdenturecanserveasatemporaryrestoration.
OverdentureUsing O-Ring System Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
59
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Laboratory Steps
Clinical Steps
Stone Master Model:ThetechnicianpoursthestonemastermodelincorporatingtheO-Ringanalogs.Abiterimisfabricatedforproperregistrationandsentbacktotheclinician.Thebiteregistrationisthenmountedwiththemastercastontothearticulator.A base plate bite rim provided by the laboratory is used to determine the proper vertical dimension.
Completethepreliminarywax-upontheprocessingmodel.Anintraoraltry-inisrecommendedforverificationoffitandesthetics.
InserttheredrubberO-Ringsintothemetalhousings.PlaceontotheO-Ringanalogs.Thesmalleropeningofthehousingispositionedocclusally.Thehousingsareblockedoutgingivallyandocclusallywithlatexmaterial.
Theacrylicisinjected/packedinonestepandshouldbesoftbeforepacking,thenpolymerizethedenture.Theacrylicisprocessedandtheoverdentureistrimmedandfinished.Sendtheoverdenturebacktotheclinicianforinsertion.
InsertthewhiteO-RingsifnotalreadyinthehousinganddeliverthefinalO-Ringoverdenture.Equilibrateasnecessary.Note:Ifusinganexistingdenture,thehousinginthedenturemaybecuredchairside.PatientFollow-Up:Afterreceivingthefinaloverdenture,thepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
60
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note: Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
MeasurethetissuedepthabovetheimplantstodeterminetheappropriateheightoftheDallaBonamaleabutments.TheshoulderoftheDallaBonaabutmentsshouldbeslightlyabovethetissue(approximately2mm).PlacetheDallaBonaabutmentsontotheimplantswiththeabutmentdriverandtorqueto30N/cm(leftgraphic).Takeanx-ray.Note:TightentheDallaBonaabutmentswithfingerpressureonlyifthehealingabutmentswillbere-insertedaftertheimpressionstage.
InjectimpressionmaterialaroundtheDallaBonaabutments.Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpression,inserttheDallaBonabrassanalogsontotheimpression.Theanalogsmaybesecuredwithwaxoradhesive.SendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarchandtheDallaBonatitaniumfemalewiththePVCringandspacer.Theexistingdenturecanserveasatemporaryrestoration.
OverdentureUsing Dalla Bona Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
61
Laboratory Steps
Clinical Steps
Stone Master Model:ThetechnicianpoursthestonemastermodelincorporatingtheDallaBonaanalogs.Abiterimisfabricatedforproperregistrationandsentbacktotheclinician.Thebiteregistrationisthenmountedwiththemastercastontothearticulator.A base plate bite rim provided by the laboratory is used to determine the proper vertical dimension.
Completethewax-upontheprocessingmodel.An intraoral try-in is recommended for verification of fit and esthetics.
PlacetheDallaBonaspacerandthetitaniumfemaleontotheDallaBonaanalogs.Note:Donotremovetherubbercoatingaroundthetitaniumfemale,asitisusedtoallowadjustments.Thegingivalmarginofthemastercastmaybeblockedoutwithlatexmaterialifneeded.
Theacrylicispacked/injectedinonestepandshouldbesoftbeforepackingandcuring.Theacrylicisprocessedandtheoverdentureistrimmedandfinished.Sendtheoverdenturebacktotheclinicianforinsertion.
ThefinalDallaBonaoverdentureisdeliveredandadjustedasnecessary.Note:Ifusinganexistingdenture,thehousinginthedenturemaybecuredchairside.TheDallaBonaactivatinganddeactivatingtoolswillberequiredforfutureadjustmentsoftheretentivetitaniumfemale.PatientFollow-Up:Afterreceivingthefinaloverdenture,thepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
62
17
18
19
20
21
2223 24 25
2627
28
29
30
31
32L RMandible
Exposetheimplantsbyremovingthestraighthealingabutmentswitha0.05“hexdriverandrinsewithanair-watersyringe.Note:Ifwaterpurityisnotconfirmed,sterilesalineorsterilewaterisrecommended.
Clinical Steps
Measurethetissueabovetheimplantstodeterminetheappropriateheightoftheoverdentureabutments.Placetheoverdentureabutmentsontotheimplantsusinga0.05“hexdrivertorqueto30N/cm.Note: Tightentheoverdentureabutmentswithfingerpressureonly,iftheabutmentswillbereinsertedaftertheimpressionstage.
Usesoftwaxorcottonpelletstoblock-outtheholesintheoverdentureabutment.Injectimpressionmaterialaroundtheoverdentureabutments.Generouslyfillthecustomizedimpressiontraywithaheavybodyimpressionmaterialandseattheimpressiontraytotaketheimpression.
Aftertakingtheimpression,inserttheoverdentureabutmentanalogsintotheimpression.Sendtheimpressiontothelaboratoryandincludetheimpressionoftheopposingarch.
OverdentureUsing Overdenture Abutments
1
2
3
4
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Prosthetic Procedures
63
Laboratory Steps
Clinical Steps
Stone Master Model:Thetechnicianpoursthestonemastermodelincorporatingtheoverdentureabutmentanalogs.Abiterimisfabricatedforproperregistrationandsentbacktotheclinician.Thebiteregistrationisthenmountedwiththemastercastontothearticulator.
TheO-ringsareblockedoutgingivallyandocclusallywithlatexmaterial.Option:Silconelinermaterialmaybeprocessedaroundtheoverdentureabutments.Properfabricationwitheitherprocessprovidesresilientfunction.
Completethepreliminarywax-upontheprocessingmodel.An intraoral try-in is recommended for passive fit verification and esthetics.
Theacrylicshouldbesoftbeforepacking,thenpolymerizethedenture.Option: Insertasiliconlinermaterialwithintheoverdentureacrylictoengagetheundercutoftheoverdentureabutment.Properfabricationwitheitherprocessprovidesresilientfunction.
Deliverthefinaloverdentureandequilibrateocclusionasnecessary.Note:Ifusinganexistingdenture,thehousinginthedenturemaybecuredchairside.PatientFollow-Up:Afterreceivingthefinaloverdenture,thepatientisgivenoralhygieneinstructions.Recallappointmentsarerecommended.
8
7
6
5
9
Prosthetic Procedures ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Surgical
2.3mmRoundBur 06-RB
2.5mmTwistDrill–short 06-2.5TDS2.5mmTwistDrill–long 06-2.5TDL
3.5mmImplantBur, 9mm 06M-9IB4.1mmImplantBur, 7mm 06-7IB4.1mmImplantBur, 9mm 06-9IB4.1mmImplantBur, 12mm 06-12IB5.0mmImplantBur, 5mm 06W-5IB5.0mmImplantBur, 7mm 06W-7IB5.0mmImplantBur, 9mm 06W-9IB5.0mmImplantBur, 12mm 06W-12IB
DrillExtension 06-DE
3.5mmTrialFitGage, 9mm 06M-9TFG/O4.1mmTrialFitGage, 7mm 06-7TFG/O4.1mmTrialFitGage, 9mm 06-9TFG/O4.1mmTrialFitGage,12mm 06-12TFG/O5.0mmTrialFitGage, 5mm 06W-5TFG/O5.0mmTrialFitGage, 7mm 06W-7TFG/O5.0mmTrialFitGage, 9mm 06W-9TFG/O5.0mmTrialFitGage,12mm 06W-12TFG/O
ParallelingPins.Packof4 06-PPMallet 06-M/LPunchHandle,straight 06-HPunchHandle,offset 06-HOSStainlessSteelPunchTip 06-PTMTipWrench 06-TWHexDriver0.05“–short 06-HDSRadiographicOverlays,Packof2 06-RO
SterilizationChart,SurgicalVideoandManual 06-SV
SurgicalInstrumentTray,empty 06-ITM/S1
Comprehensive Surgical Kit Item-No. Endopore Osteotome Kit Item-No.
OsteotomeTip#1OsteotomeTip#2OsteotomeTip#3
StainlessSteelPunchTipPunchHandle,straight,Packof4PunchHandle,offsetMallet
OsteotomeInstrumentTray,empty
06-OT106-OT206-OT3
06-PTM06-H06-HOS06-M/L
06-ITM/S2
Endopore Surgical Kits
forusewithallEndoporeImplantswithInternalConnection,InternalHexandExternalHex.
64
ENDOPORE® Surgical
Endopore Surgical Instrumentation
Implant Burs Length Item-No.
9mm 06M-9IB
7mm 06-7IB
9mm 06-9IB
12mm 06-12IB
5mm 06W-5IB
7mm 06W-7IB
9mm 06W-9IB
12mm 06W-12IB
Implant Burs
ForimplantØ3.5mm
ForimplantØ4.1mm
ForimplantØ5.0mm
Burs and Drills Item-No.
CrestotomForsmoothingandlevellingofthealveolarcrest
Initial Perforation (IP) Drill Forinitialperforationofthecompactcorticalbone,Ø2.00
Round Bur Ø2.3mm
Twist DrillShort,Ø2.5mm,totallength30mmLong,Ø2.5mm,totallength39mm
1452
90024
06-RB
06-2.5TDS
06-2.5TDL
65
Surgical ENDOPORE®
Drill Extension Item-No.
Drill Extension 06-DE
Trial Fit Gages/Osteotome Final Tips Length Item-No.
Trial Fit Gages/Osteotome Final TipsThetrialfitgagesarethreadedtoconnecttothepunchhandles.Thetrialfitgagecorrespondingtothesizeoftheimplanttobeplaced,actsasthefinalosteotometip.
ImplantØ3.5mm
ImplantØ4.1mm
ImplantØ5.0mm
9mm 06M-9TFG/O
7mm 06-7TFG/O
9mm 06-9TFG/O
12mm 06-12TFG/O
5mm 06W-5TFG/O
7mm 06W-7TFG/O
9mm 06W-9TFG/O
12mm 06W-12TFG/O
Paralleling PinForusewith2.5mmtwistdrill
06-PP
Mallet and Punch Handles Item-No.
Mallet 06-M/L
Punch HandlesForuseinconjunctionwithosteotometipsandtrialfitgagesforosteotometechnique
straight
offset
06-H
06-HOS
straight offset
Paralleling Pin Item-No.
66
ENDOPORE® Surgical
Tissue Punch Item-No.
Tissue PunchThemetaltissuepunchattachestothedrillhandpieceandwillcleanlysectiona4.3mmdiameterflapoftissueovertheimplant.
06-TP
Punch Tips Item-No.
Stainless Steel Punch TipStainlesssteelpunchtipforimplantplacement.Forusewithalldiameters.Connectstopunchhandle.
06-PTM
Osteotome Punch TipsOsteotomepunchtipsconnecttothepunchhandles.
OsteotomeTip#1OsteotomeTip#2OsteotomeTip#3
06-OT106-OT206-OT3
Wrench and driver Item-No.
Tip WrenchThetipwrenchisusedfortighteningorlooseningtrialfitgages,punchtipandosteotometipstothepunchhandles.
06-TW
Hex Driver 0.05” – short 06-HDS
Cover Screw Trephines Item-No.
Cover Screw TrephinesForimplantØ3.5mm
ForimplantØ4.1mm
ForimplantØ5.0mm
06M-3.5TR/CS
06-4.1TR/CS
06W-5.0TR/CS
Tip #1 Tip #2 Tip #3
13 mm
for Ø 3.5 mm for Ø 4.1 mm for Ø 5.0 mm
67
Surgical ENDOPORE®
Endopore Hybrid Surgical Kits
Comprehensive Surgical Kit Item-No.
ForusewithallEndoporeHybridExternal&EndoporeHybridInternalHexImplants.
SurgicalInstrumentTray 06H-IT/S
RoundBur 06-RB
2.5mmTwistDrill–short 06H-2.5TDS2.5mmTwistDrill–long 06H-2.5TDL4.0mmImplantBur,9.5mm 06H-9.5IB4.0mmlmplantBur,11mm 06H-11IB4.75mmlmplantBur,7.5mm 06WH-7.5IB4.75mmImplantBur,9.5mm 06WH-9.5IB
DrillExtension 06-DE4.0mmTrialFitGage,9.5mm 06H-9.5TFG/O4.0mmTrialFitGage,11mm 06H-11TFG/O4.75mmTrialFitGage,7.5mm 06WH-7.5TFG/O4.75mmTrialFitGage,9.5mm 06WH-9.5TFG/OParallelingPin 06-PP
4.0mmBoneTap 06H-4.0TAP4.75mmBoneTap 06H-4.75TAP
DriverHousing 07-0190HexDriver0.05“–short 06-HDSDriverExtension 07-0195DrillDriver 03-DDHRatchetWrench 03-RWTipWrench 06-TWDriverBody–long 03-DBLRadiographOverlays,Packof2 06H-RO
SurgicalManualandVideoonDVD 06H-SV
Hybrid Osteotome Kit Item-No.
OsteotomeTip#1 06H-OT1OsteotomeTip#2 06H-OT2OsteotomeTip#3 06H-OT3
PunchHandle,straight 06-H
PunchHandle,offset 06-HOS
Mallet 06-M/L
OsteotomeInstrumentTray,empty 06-ITM/S2
68
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Surgical
Endopore Hybrid Surgical Instrumentation
Endopore Hybrid Instrument Trays Item-No.
CrestotomForsmoothingandlevellingofthealveolarcrest
Initial Perforation (IP) Drill forinitialperforationofthecompactcorticalbone,Ø2.00
1452
90024
Round Bur Item-No.
Round Bur Ø2.3mm
06-RB
Implant Burs Length Item-No.
9.5mm 06H-9.5IB
11mm 06H-11IB
7.5mm 06WH-7.5IB
9.5mm 06WH-9.5IB
Implant BursForimplantØ4.0mm
ForimplantØ4.75mm
Twist Drills Item-No.
Twist Drill – shortØ2.5mm,totallength30mm
Twist Drill – long
06H-2.5TDS
06H-2.5TDL
Trial Fit Gages Length Item-No.
9.5mm 06H-9.5TFG
11mm 06H-11TFG
7.5mm 06WH-7.5TFG
9.5mm 06WH-9.5TFG
Trial Fit GagesForimplantØ4.0mm
ForimplantØ4.75mm
69
Surgical ENDOPORE® Hybrid
Paralleling Pin Item-No.
Paralleling PinForusewith2.5mmtwistdrill
06-PP
Osteotome Hybrid Punch Tips Item-No.
Osteotome Hybrid Punch TipsOsteotomepunchtipsconnecttothepunchhandles.
OsteotomeTip#1OsteotomeTip#2OsteotomeTip#3
06H-OT106H-OT206H-OT3
Tip Wrench and Driver Item-No.
Tip WrenchThetipwrenchisusedfortighteningorlooseningtrialfitgages,punchtipandosteotometipstothepunchhandles.
06-TW
Hex Driver 0.05” – short 06-HDS
13mm
Driver Housing and Extension Item-No.
Bone Taps Item-No.
Bone TapsForimplantØ4.0mm
ForimplantØ4.75mm
06H-4.0TAP
06H-4.75TAP
Tip #1 Tip #2 Tip #3
Driver Housing
Driver Extension
07-0190
07-0195
Driver Housing Driver Extension
70
ENDOPORE® Hybrid Surgical
Ratchet Wrench Item-No.
Ratchet Wrench 06-RW
Drill Extension and Driver Item-No.
Drill Extension 06-DE
Drill Driver 03-DDH
Driver Body, long 03-DBL
Driver Extension 07-0195
71
Surgical ENDOPORE® Hybrid
2.3mmRoundBur 06-RB
2.0mmTwistDrill 03-2.0TD2.6mmTwistDrill,Short 03-2.6TDS2.6mmTwistDrill,Long 03-2.6TDL3.0mmTwistDrill 03-3.0TDX3.25mmTwistDrill,Short 03-3.25TDS3.25mmTwistDrill,Long 03-3.25TDL3.75mmTwistDrill 03-3.75TDX4.0mmTwistDrill,Short 03-4.0TDS4.0mmTwistDrill,Long 03-4.0TDL4.5mmTwistDrill 03-4.5TDX
2.6mmParallelingPins,Packof5 03-2.6PP
3.25mmCountersink(3.5mmplatform) 03M-3.25CSK3.25mmCountersink(4.1mmplatform) 03-3.25CSK4.75mmCountersink(5.0mmplatform) 03-4.75CSK
3.25mmBoneTap 03-3.25TAP4.0mmBoneTap 03-4.0TAP4.75mmBoneTap 03-4.75TAP
DrillExtension 06-DE
DepthGage#1(8,10,18,21mm) 03-DG1
Comprehensive Surgical Kit Item-No.
DepthGage#2(13,15mm) 03-DG2
DrillDriver 03-DDH
RatchetWrench 03-RW
DriverHousing 07-0190DriverExtension 07-0195DriverBody,Long 03-DBL3.5mmDriverBody,Long 03M-DBLHexDriver0.05“ 03-HD50
RadiographicOverlay,Packof2 03-RO
SterilizationChart,SurgicalVideoandManual 03-SV
Entegra™SurgicalInstrumentTray,Empty 03-IT/S
Item-No.
Entegra Surgical Kit
72
ENTEGRATM Surgical
Entegra Surgical Instrumentation
Item-No.
CrestotomFortheremovalofsofttissue,forsmoothingandlevellingofthealveolarcrest
Initial Perforation (IP) Drill forinitialperforationofthecompactcorticalbone,Ø2.00
Round Bur Ø2.3mm
Implant Twist DrillsDrillsequencebyimplantdiameter2.0mmTwistDrill
2.6mmTwistDrill,short
2.6mmTwistDrill,long
3.0mm*TwistDrill
3.25mmTwistDrill,short
3.25mmTwistDrilll,long
3.75mm*TwistDrill
4.0mmTwistDrill,short
4.0mmTwistDrilll,long
4.5mm*TwistDrill
Note:Shorttwistdrillshaveanoveralllengthof29mmandthelongtwistdrillsare38mm.
Paralleling Pin2.6mm(Forusewiththe2.6mmtwistdrill)
Countersinks3.25mm(Forusewith3.25mmimplantwith3.5mmplatform)
3.25mm(Forusewith3.25mmimplantwith4.1mmplatform)
4.75mm(Forusewith4.75mmimplantwith5.0mmplatform)
Bone Taps3.25mm(Forusewiththe3.25mmimplant)
4.0mm(Forusewiththe4.0mmimplant)
4.75mm(Forusewiththe4.75mmimplant)
1452
90024
06-RB
03-2.0TD
03-2.6TDS
03-2.6TDL
03-3.0TDX*
03-3.25TDS
03-3.25TDL
03-3.75TDX*
03-4.0TDS
03-4.0TDL
03-4.5TDX*
03-2.6PP
03M-3.25CSK03-3.25CSK03-4.75CSK
03-3.25TAP03-4.0TAP03-4.75TAP
*OversizeddrillsaresuppliedforuseinType1bone,when
necessarytoexpandtheosteotomyforeaseofinsertion.
73
Surgical ENTEGRATM
Drill Extension 06-DE
Entegra Surgical Instrumentation
Item-No.
Depth Gage DepthGage#1(Forusewiththe8,10,and18mmimplants)
DepthGage#2(Forusewiththe13and15mmimplants)
03-DG1
03-DG2
Drill Driver 03-DDH
Ratchet Wrench 03-RW
Driver Body, LongDriverBody,Long(Extensionforinsertionofthe3.25[withthe4.1mmplatform],4.0and4.75mmimplants)
3.5mmDriverBody,Long(Extensionforinsertionofthe3.25mmimplantwiththe3.5mmplatform)
03-DBL
03M-DBL
Hex Driver 0.05“ 03-HD50
Driver Housing
Driver Extension
07-0190
07-0195
Driver Housing Driver Extension
74
ENTEGRATM Surgical
Surgical Motors and Equipment
Item-No.
W&H Motors and AccessoriesElcomedSA200-CSurgicalMotor 09-ELCO200-CElcomedSA200SurgicalMotor 09-ELCO200ImplantMedSurgicalMotor 09-ISMElcomed200&ImplantMedTravelCase 09-IMPCC20:1SurgicalContra-AngleHandpiece 09-EMHP(WI-75E)20:1SurgicalContra-AngleHandpiece 09-EMHP(WS-75E)1:2,7SurgicalContra-AngleHandpiece 09-EMHP(1:2,7)1:1SurgicalStraightHandpiece 09-EMHP(S11)1:2SurgicalAngledHandpiece 09-EMHP(S12)SterileSalineTubing(Packof10) 09-EMSTElcomedSA200/100TubeClamps(Packof10) 09-EMTCImplantMedTubeClamps(Packof5) 09-IMTCElcomedSA200/100IrrigationSpikeAssembly 09-EMISISM/ImplantMedIrrigationSpikew/RollerClamp 09-EMIS/CElcomedSA200FeedTubew/Connectors 09-SAFT/CElcomed100FeedTubew/Connectors 09-EMFT/CISM/ImplantMedFeedTubew/Connectors 09-IMFT/CElcomedSA200FeedTubes(Packof3) 09-SAFTElcomed100FeedTubes(Packof5) 09-EMFTISM/ImplantMedFeedTubes(Packof3) 09-IMFTInternalBurCoolantTube 09-EMIBSterilizingProtector 09-EMSPIrrigationSpikeTube 09-EMIS/TY-Connector 09-EMYCSlow-Blow4AFuse115V 09-EMFUSEY-ConnectorTubeAssembly(Packof2) 09-EMYCT
Split-Control Bone Spreading and Condensing SystemCompleteSystem INN-SC0I
InitialBur,1.8mm 186RFInitialBur,1.0mm 859FOsteotomyDisk 231DCPilotBurs A1001/D1001ExpansionBurs A1003/D1003Spreaders A1005toF1005Wrench CA00SCarriers CAOKG/CAOOG
Ratchet System CompleteSystem CA3900RA
Adapter 39CA2RATorqueRatchetHandle CA0RAShortRAAdapter 39CA2RALongRAAdapter 39CA3RA
75
Surgical ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM
Regeneration Products
CytoplastTM Non Resorbable Membranes Size Qty. Item-No.
Cytoplast™ GBR-200AhighdensityPTFEmembraneprotectsagainstbiomaterialcenteredinfections.
Cytoplast™ TXT-200MicromachineduppersurfaceareaofthehighdensityPTFEmembraneallowsforadditionalcelladhesion.
Cytoplast™ TI-250AhighdensityPTFEmembranewithatitaniumreinforcement.
CytoplastTM Resorbable Membranes Size Qty. Item-No.
Cytoplast™ RTMCytoplast™RTMisatype1bovinecollagenmatrixandisindicatedforuseinguidedtissueregenerationprocedurestoenhancewoundhealing.Cytoplast™RTMoffersthefollowingbenefits:•Optimizedflexibilityandrigidity
forbetterspacemaintenance•Highermechanicalstrengthfor
membranestabilizationinsitu•Predictableresorptiontimeof26to38weeks
15x20mm 1 RTM152020x30mm 1 RTM203030x40mm 1 RTM3040
25mmx30mm 4 GBR-20012mmx20mm 10 GBR-200SINGLES
25mmx30mm 4 TXT-20012mmx20mm 10 TXT-200SINGLES
25mmx30mm 2 Ti-25012mmx20mm 4 Ti-250SINGLES
76
ENDOPORE®/ENDOPORE® Hybrid/ENTEGRATM Surgical
5.0cc 02-2010-050
2.5cc 02-2010-0251.0cc 02-2010-010
5.0cc 02-2000-0501.0cc 02-2000-0100.5cc 02-2000-005
DynaGraft®IIPuttyandGelarepowerfulmixturesofdemineralizedbonematrix(DBM)inareversephasemediumwhichthickensatbodytemperaturetokeeptheDBMatthesurgicalsite.DynaGraft®IIholdsuptoirrigationandremainswherethepatientneedsitmost.EverylotofDBMusedinDynaGraft®IIistestedinavalidatedinvitroassaytoensureitisosteoinductive.
DynaGraft® II Putty
DynaGraft® II Gel
DynaGraft® II Qty. per box Item-No.
Cytoplast® PTFE Sutures Compares in Diameter Needle Compare Point Description
CS-04 USP2-0 C-6 FS-2 18.7mm3/8Circle ReverseCuttingCS-05 USP3-0 C-22 FS-3 16.3mm3/8Circle ReverseCuttingCS-06 USP4-0 C-22 FS-3 16.3mm3/8Circle ReverseCuttingCS-06Perio USP4-0 T-22 TF 12.7mm1/2Circle TaperPointCS-06Premium USP4-0 C-3 P-3 13.1mm3/8Circle PremiumReverse Cutting
77
Alphabetical order ENDOPORE®
Order Form
Billing Information
Shipping Information
Shipping Method
Payment Method
Product Order
Please fax completed form to Innova Customer Service at 416.340.0415
CustomerName AccountNo.
OrderDate OrderPlacedBy P.O.No.
Street City Province/State Postal/ZipCode
Telephone Fax E-mail
Name Telephone
Street
City Province/State Postal/ZipCode
United States Canada8am(whereavailable) 2Days(before5pm) 9a.m.(whereavailable) 2Days(before5pm)Priority(10:30am) 3Days(before5pm) Priority(10:30amornoon)StandardOvernight(before5pm) Saturday(before5pm) Standard(5pm)
COD BillNet30 CreditCard: Visa Mastercard Amex
CreditCardNo. ExpiryDate
NameofCardholder Signature
CatalogNumber Quantity Description
78
Innova Implant Systems Order Form
Endopore®
is still the world’s shortest implant with 16 years of proven clinical success!
Endopore® Hybrid® PITT-EASY® Anatomic®
A World of Implant SolutionsInnovahasbeenaleadinginnovatorinthedevelopmentofdentalimplantsfornearlytwodecades.Ourcompletelineofimplantsystems–includingEndopore®,stilltheworld’sshortestimplant–isusedwithgreatsuccessbypractitionersaroundtheglobe.
Products – ourcomprehensivecatalogofimplantsystemsprovidesworld-classsolutionsforeverypatient’sneeds.
Education – wearededicatedtoadvancingyourskillsandknowledgebyprovidingafullrangeofeducationalprogramsandseminars.Foracompletelistingofourworldwideeducationalofferingsvisitwww.innovalife.com
Innovation.It’s in our name. In our products. In your future!
Innova CorporationCorporateOffice522UniversityAve,Suite1200Toronto,ONM5G1W7Canada+1.416.340.8818Tollfree800.898.6261
06/11 PC 001 EN
Service – we’realwaysthereforyou,withpersonal,professionalsupportrightinyouroffice.
Future-driven – wearecontinuouslydevelopingthepracticalanduniqueimplantsolutionsyouneedtodayandwillneedtomorrow.
Guaranteed success – everyInnovaimplantandcomponentisguaranteedforthelifetimeofthepatient.
Regional Offices:
Sydney, Australia+61.2.9363.0224
Bremen, Germany+49.421.43939.0
www.innovalife.com