Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
Affiliate with the N.V. KEMA in The Netherlands
CERTIFICATECertificate Number: 510040.001 The Quality System of: Thomson Inc, and its wor dwide Grass Valley division affiliates DBA GRASS VALLEY
Headquarters 400 Providence Mine Rd Nevada City, CA 95959 United States
15655 SW Greystone Ct. Beaverton, OR 97006 United States
10 Presidential Way Suite 300 Woburn, MA 01801 United States
Kapittelweg 10 4827 HG Breda The Nederlands
7140 Baymeadows Way Ste 101 Jacksonville, FL 32256 United States
2300 So. Decker Lake Blvd. Salt Lake City, UT 84119 United States
Rue du Clos Courtel CS 31719 35517 Cesson-Sevigné Cedex France
1 rue de l’Hautil Z.I. des Boutries BP 150 78702 Conflans-Sainte Honorine Cedex France
Technopole Brest-Iroise Site de la Pointe du Diable CS 73808 29238 Brest Cedex 3 France
40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France
Spinnereistrasse 5 CH-5300 Turgi Switzerland
Brunnenweg 9 D-64331 Weiterstadt Germany
Carl-Benz-Strasse 6-8 67105 Schifferstadt Germany
Including its implementation, meets the requirements of the standard:
ISO 9001:2008 Scope:The design, manufacture and support of video and audio hardware and software products and related systems.
This Certificate is valid until: June 14, 2012 This Certificate is valid as of: June 14, 2009 Certified for the first time: June 14, 2000
H. Pierre Sallé President KEMA-Registered Quality
The method of operation for quality certification is defined in the KEMA General Terms And Conditions For Quality And Environmental Management Systems Certifications. Integral publication of this certificate is allowed.
KEMA-Registered Quality, Inc.4377 County Line Road Chalfont, PA 18914 Ph: (215)997-4519 Fax: (215)997-3809 CRT 001 073004
Accredited By:ANAB
4 Encore — Control Panels Operation Manual
Contacting Grass ValleyInternational
Support CentersFrance24 x 7 +800 8080 2020 or +33 1 48 25 20 20 United States/Canada
24 x 7 +1 800 547 8949 or +1 530 478 4148
Local Support Centers
(available during normal
business hours)
AsiaHong Kong, Taiwan, Korea, Macau: +852 2531 3058 Indian Subcontinent: +91 22 24933476Southeast Asia/Malaysia: +603 7805 3884 Southeast Asia/Singapore: +65 6379 1313China: +861 0660 159 450 Japan: +81 3 5484 6868
Australia and New Zealand: +61 1300 721 495 Central/South America: +55 11 5509 3443
Middle East: +971 4 299 64 40 Near East and Africa: +800 8080 2020 or +33 1 48 25 20 20
Europe
Belarus, Russia, Tadzikistan, Ukraine, Uzbekistan: +7 095 2580924 225 Switzerland: +41 1 487 80 02S. Europe/Italy-Roma: +39 06 87 20 35 28 -Milan: +39 02 48 41 46 58 S. Europe/Spain: +34 91 512 03 50Benelux/Belgium: +32 (0) 2 334 90 30 Benelux/Netherlands: +31 (0) 35 62 38 42 1 N. Europe: +45 45 96 88 70Germany, Austria, Eastern Europe: +49 6150 104 444 UK, Ireland, Israel: +44 118 923 0499
Copyright © Grass Valley, Inc. All rights reserved.This product may be covered by one or more U.S. and foreign patents.
Grass Valley Web Site The www.grassvalley.com web site offers the following:
Online User Documentation — Current versions of product catalogs, brochures, data sheets, ordering guides, planning guides, manuals, and release notes in .pdf format can be downloaded.
FAQ Database — Solutions to problems and troubleshooting efforts can be found by searching our Frequently Asked Questions (FAQ) database.
Software Downloads — Download software updates, drivers, and patches.
ContentsPreface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Documentation Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Section 1 — Encore System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Controlled Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Encore System Controller Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Encore System Control Fundamentals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Distributed Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Encore Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Sharer Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Configuration PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Sharer PC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Routing Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Matrix Crosspoints and Levels Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Sources and Destinations Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Multi-Level Switching Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
All Level Take. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Breakaway Take . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Tie-Line Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Section 2 — Control Panels Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Control Panel Hardware Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Encore Control Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23SMS 7000 Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Kalypso Remote Aux Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Acappella Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Soft Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Control Panel Communications Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Control Panel Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Control Panel Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Control Panel Defaults (Factory and Facility) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Factory Default Templates and Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Control Panel Sign On Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Control Panel Basic Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Protect and Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Salvos Excluded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Chop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Chop Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Encore — Control Panels Operation Manual 5
Contents
Control Panel Chop Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Chop Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Chop Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Control Panel Shift Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Shift Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Shift Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Destination Ganging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Destination Ganging Configuration for v1.8.0 Software. . . . . . . . . . . . . . . . . 30Destination Ganging Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Breakaway Takes and Ganging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Protect and Ganging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Section 3 — Encore Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Panel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
PMB Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PMB Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PMB Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PMB Panel Default Button Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Taking a Source to a Destination (PMB Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . 35Breakaway Take (PMB Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Level Tally (PMB Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Protect (PMB Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
To Protect a Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38To Unprotect a Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Salvo (PMB Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Dynamic Page Set Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Dynamic Page Set Panel Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Dynamic Page Set Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
XY Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40XY Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40XY Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40XY Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Status Display Reporting of Source and Destination . . . . . . . . . . . . . . . . . . . . . 41Taking a Source to a Destination (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Using Dedicated Destination and Source Buttons . . . . . . . . . . . . . . . . . . . . . . 41Switching Non-Dedicated Sources to Destinations . . . . . . . . . . . . . . . . . . . . . 41
Breakaway Take (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Protect (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Salvo (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
BPS Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44BPS Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44BPS Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44BPS Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Default BPS Single Destination Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Taking a Source to a Destination (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Breakaway Take (BPS Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Protect (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Salvo (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Self Configuration (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Source Self Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
6 Encore — Control Panels Operation Manual
Contents
Level Self Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Salvo Self Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
48B Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4748B Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4748B Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4748B Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Taking a Source to a Destination (48B Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Breakaway Take (48B Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Auto Tally and the Tally Level Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Tally Level Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Protect (48B Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Salvo (48B Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Universal Control Panel (ENC-UCP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UCP Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UCP Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UPC Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UCP Standalone Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Client Control Panel (ENC-CLNT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52ENC-CLNT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52ENC-CLNT Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Changing Destinations on a Client Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Identifying Assigned Client Panel Destinations . . . . . . . . . . . . . . . . . . . . . . . . 53Assigning Sources to Client Panel Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Identifying Client Panel Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Taking a Source to a Destination (CLNT Panel) . . . . . . . . . . . . . . . . . . . . . . . . 53Quick Take Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Section 4 — SMS7000 GSC Control Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55UCP Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
UCP Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56UCP Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56UCP Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Taking a Source to a Destination (UCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Breakaway Take (UCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Protect (UCP Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Salvo (UCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
CLNT Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59P32 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
P32 Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59P32 Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59P32 Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Taking a Source to a Destination (P32 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Breakaway Take (P32 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Protect (P32 Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
MB8 Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Default Button Configuration (MB8 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61MB8 Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
MB4 Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62MB4 Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Default Button Configuration (MB4 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63MB4 Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Hold Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Encore — Control Panels Operation Manual 7
Contents
Load Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64EDP Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
EDP Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Default Button Configuration (EDP Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
P48 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65P48 Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Default Button Configuration (P48 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
PXY Panel Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66PXY Panel Set Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66PXY Panel Set Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66PXY Group Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
PXS Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67PXD Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67PXYE Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
PXS Source/Level Mode Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Taking a Source to a Destination (PXS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Taking a Source to a Destination (PXY Panel Group) . . . . . . . . . . . . . . . . . . . . . 68Breakaway Take (PXS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Protect (PXS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
SCP - Simple Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68SCP Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Default Button Configuration (SCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69SCP Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Section 5 — Kalypso Remote Aux Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Remote Aux Panel Model Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
KMD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72KMD Panel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Default Button Configuration (KMD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73KMD Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
KSD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Default Button Configuration (KSD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74KSD Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Section 6 — Acappella Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Acappella Remote Panel Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Acappella Local Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Default Button Configuration (Acappella Remote Panel) . . . . . . . . . . . . . . . . . . . 77Acappella Remote Panel Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Section 7 — JEP-100 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
JEP-100 Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
JEP-100 Panel Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80JEP-100 Default Button Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
JEP-100 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
8 Encore — Control Panels Operation Manual
Contents
Selecting a Destination to Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Taking a Source to a Destination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Using Assigned Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Using Scrolling Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Breakaway Take (JEP-100 Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Using Assigned Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Using Level Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Locking or Protecting a Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Salvos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Front Panel Button Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Front Panel Menu Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Section 8 — Panel Operation Variations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Button Functions and Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Exclusion Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Keypad Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Page Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Dynamic Audio Attribute Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Dynamic Audio Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Dynamic Audio Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Attributes and Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88General Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Auto Tally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Auto Level Latching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Default Tally Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Display Alias Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Dst Change Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Level Change Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Protect and Lock Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Hard Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Soft Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Lock/Protect Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Force Unlock/Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Salvo Editor Lock/Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Control Panel Grouping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Joystick Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Joystick Override Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Joystick Override Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Encore — Control Panels Operation Manual 9
Preface
About This ManualThis Encore Control Panels Operation Manual is designed for operators of a Grass Valley Encore control system who are not involved in Encore system configuration or servicing.
Documentation SetThe basic Encore documentation set consists of:
• Installation and Service Manual,
• Configuration Manual,
• Control Panels Operation Manual, and
• Release Notes.
The Installation and Service Manual contains information about installing Encore system hardware, maintaining Encore system components, and configuring network communications used by the system.
The Configuration Manual contains information about configuring an Encore system to meet the needs of your facility. Background information about Encore system design is included, and a description of the Encore Operator User Interface (OUI); which is used to configure, test, and operate the system; is also provided.
The Control Panels Operation Manual provides operating information for the control panels used with the Encore Control System.
The Release Notes contain information about new features and system enhancements for a specific software version. Software installation proce-dures are also provided. Always review the Release Notes for your current system software before you begin working with your Encore system.
Encore — Control Panels Operation Manual 11
Preface
Additional DocumentationDocumentation for various Encore system options is also available:
• Encore Salvo Editor Instruction Manual,
• Soft Panels Instruction Manual, and
• Visual Status Display Instruction Manual.
The NetConfig utility program is used to configure your Encore network and install software:
• NetConfig Instruction Manual
Software engineering documentation, intended for third-party developers and in-house software engineers, is also available:
• Routing Products Protocols Manual.
12 Encore — Control Panels Operation Manual
Section 1Encore System Overview
Note This same Overview section is included in several Encore manuals. If you are familiar with this material you can skip to the next section.
IntroductionThe Encore system is an open, scalable platform for full router and facility control. Featuring tight integration with Grass Valley router matrices, third-party routers, automation systems, and other equipment, the Encore system can consolidate media assets under a single, unified control system.
Figure 1. Encore Facility Control System
Encore SystemController(s)
EncoreSerial Controller
VTRs
Profile VDRs
Acts AsGatewayBetweenEN 1 and
EN 2
Encore OperatorWorkstation(s)
Notification viaPager, E-mail
or Phone
Trinix Digital VideoRouting Matrix
Apex Digital AudioRouting Matrix
AcappellaRemote Panels
AcappellaRouting Matrices
Encore EthernetControl Panels
PMB
48BEDP
P32
UCP
MB8
P48
XY
BPS
Series 7000Routing Matrices
SMS 7000Control System
ConcertoMulti-Format
Routing Matrix
7500 WB Digital Video Routing Matrix
7500 NB Digital AudioRouting Matrix
NetCentralSNMP Manager
Distributed Applications:
Serial Interface Options:
• System Manager• Router Control• Panel Servers• Tie-Line Manager
Encore EngineeringWorkstation
Windows GUI Applications:
Windows GUI Applications:
• Configuration• Local Router Panel• Local Machine Control Panel• Router Status
• Local Router Panel• Local Machine Control Panel
• Automation• ES Switch/Jupiter• 3rd Party Matrix/Tally• Horizon Matrix
RS-4
22
Cros
spoi
nt B
us
8053
_00r
0
Encore Controllerwith GSC Option
Encore Controller withRS-422 Serial Option
75 Ω
Coa
x Series 7000Control Panels
EN 1 Ethernet (Facility LAN) EN 2 Ethernet (Panel/Matrix LAN)
RS-4
22
Encore — Control Panels Operation Manual 13
Section 1 — Encore System Overview
The Encore system modular design lets broadcasters and other high-quality content creators select just the level of control they need. At its most basic, the Encore system can configure and control the crosspoints of a single routing matrix, but it can be expanded to control multiple matrices.
Controlled HardwareEncore can control a wide range of Grass Valley routers including Trinix, Apex, Concerto, Acappella, 7500 WB, and 7500 NB using Ethernet. Legacy 7000 Series and Horizon routers can be serially controlled. In addition, Encore can control the popular Grass Valley Venus routers with a serial interface to a VM-3000 protocol translator. A wide range of third party routers can also be controlled through a number of supported serial inter-faces. Users can also add tally and machine control via Ethernet or serial interfaces.
Encore System Controller FrameThe two rack-unit Encore System Controller Frame supports up to two System Controller Board (SCB) modules and two power supply modules for redundancy. A standard Encore System Controller Frame is equipped with one SCB and one power supply. All modules are front removable and hot pluggable. Cooling is built into the frame so no external cooling units are required.
Figure 2. Encore System Controller Frame
8053_09r0
14 Encore — Control Panels Operation Manual
Introduction
The System Controller Frame has two slots for SCBs and two slots for Power Supply modules, located behind the front cover/air filter. Status indicator LEDs and a reset button are located on each SCB (Figure 3).
Figure 3. System Controller and Power Supply Modules
Power Supply Modules
Reset Buttons
System Controller Modules
8053
_36r
0
Slot 1Slot 2
Slot 1Slot 2
Cabling and power connectors are located on the rear of the System Con-troller Frame (Figure 4).
Figure 4. System Controller Frame Rear View
8053_37_r0
J31USB J19J20J21J29J30
GPIIN
GPIOUT J5J6J7
GSC 4 GSC 3 GSC 2 GSC 1 REF OUT SYNC 2 SYNC 1
CONSOLECONSOLE
J1J2J3J4
J16
J35
J51
COM1
COM2
J52J53
EN1
EN2
J54
J36J37J38J39SIO 45678 3 2 1
J40J41J42J43J44J45J46J47J48J49J50
J17J18 J15J26J27J28J32J33
GPIIN
GPIOUT J12J13J14
GSC 4 GSC 3 GSC 2 GSC 1 REF OUT SYNC 2 SYNC 1
J8J9J10J11
J23J24J25 J22J34USBPS1
PS2
COL LNKLNK COL COL LNKLNK COL
J55
+
J56
COM1
COM2
J57J58
EN1
EN2
J59
SIO 45678 3 2 1
30-60V130W; 3.7A
Serial In/OutConnectors (8)
Com 1Console Port
EN1Ethernet Port
EN2Ethernet Port
SCB Slot 2 Connectors
DCPower
GPI In/OutConnectors (2)
GSC BNCs (8) Sync BNCs (4)
Com 2Port
SCB Slot 1 Connectors
GPI In/OutConnectors (2)
GSC BNCs (8) Sync BNCs (4)
Serial In/OutConnectors (8)
Com 1Console Port
EN1Ethernet Port
EN2Ethernet PortAC
Power
Com 2Port
Multiple Encore System Controller Frames can be used to support large systems and to increase throughput by dividing tasks among the control-lers. SCBs in the same frame can be configured to control different hard-ware or to operate redundantly. An SCB in one frame can even operate redundantly with an SCB in a different frame.
Encore — Control Panels Operation Manual 15
Section 1 — Encore System Overview
Control PanelsA wide variety of hardware control panels are available that can work across the room or across the country via IP LAN/WAN connections. Many Grass Valley legacy hardware control panels can also be used with optional serial interfaces. Optional PC control panel software is also available that emulates many of these hardware panels.
The control panel operator views and selects Sources and Destinations by name and does not need to be concerned with the actual physical cabling or numbers of inputs and outputs.
Two representative Encore control panels are illustrated below.
Figure 5. Encore Paging Multi Bus (PMB) Control Panel
Status 1
Des t inat ion 1
P reset
Leve l
Status 2
Des t inat ion 2
Status 3
Des t inat ion 3
Status 4
Des t inat ion 4
Status 5
Des t inat ion 5
Status 6
Des t inat ion 6
Status 7
Des t inat ion 7
Status 8
Des t inat ion 8
DestDest
IDID
LevelLevel SrcSrc
DestDestPagePage
LevelLevelPagePage
SrcSrcPagePage
SalvoSalvoPagePage
ChopChop
CECE
ClearClear
ShiftShiftA
PrevPrev NextNext
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
8053_03r0
Figure 6. Encore Button Per Source (BPS) Control Panel
Des t inat ion Status
ProtProt
Lvl 1Lvl 1
ChopChop
Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 5Lvl 5
NextNext
Lvl 6Lvl 6Lvl 4Lvl 4
PrevPrev
All LvlsAll Lvls
ConfigConfig
TallyTally
IDID
8053_04r0
An Acappella control panel and an SMS7000 control panel, both originally developed for other routing systems but able to be configured to work with Encore, are illustrated below.
Figure 7. Acappella 16x16 Remote Panel
8053_05r0
Figure 8. SMS7000 P48 Control Panel
Grass ValleyGrass Valley
PROT CHOPID
TALLYLEVEL
ALLLVLS
LVL1
LVL2
LVL3
LVL4
LVL6
LVL5
8053_08r0
16 Encore — Control Panels Operation Manual
Introduction
Encore System Control Fundamentals
Distributed Control System
The Encore system uses a distributed control networked architecture. Various Encore software components are installed on different hardware locations to perform different tasks. This design provides extraordinary system power and flexibility. Configuration files are downloaded over the network to target devices, permitting rapid configuration changes while the Encore system remains operational. User-specific system-wide access privileges can also be established to restrict system control as appropriate.
Encore Database
Information vital to Encore system operation resides in a collection of data files, collectively called the Encore database. These files model the routing matrix hardware being controlled, name input Sources and output Destina-tions, determine matrix Levels, and specify the operational capabilities of the control panels. The Encore database is created when the system is com-missioned and is typically maintained by facility engineering staff. The Encore database resides on the same PC as the Sharer.
Sharer Application
The Sharer application automatically downloads configuration informa-tion to Encore system components when they are power up or reboot. The Sharer application runs on a PC, and must be running when the Encore system is configured. The Sharer does not need to be running to sustain control panel operation. However, we recommend the Sharer application run at all times, as this makes it easier to resume configuration procedures.
CAUTION An Encore system can have only one Sharer application running on the network at any time. This is important to remember during software installa-tion, or if a notebook PC with the Sharer is moved to different locations.
Configuration PC
An Encore system is configured using a standard PC installed with the appropriate Encore software. Once configured, Encore control panels will be able to switch crosspoints on routing matrices even if the configuration PC is turned off or disconnected from the network. Typically the configu-ration PC also has the Encore Sharer application installed, but this applica-tion can reside on any PC on the network.
Encore — Control Panels Operation Manual 17
Section 1 — Encore System Overview
Sharer PC
The Sharer PC is the PC on which the Sharer is installed. Typically the con-figuration PC and Sharer PC are the same, but separate PCs can be used.
Routing Basics
TerminologyArea - An Area is a defined group of Sources and Destinations. Takes are restricted to connecting Sources and Destinations within the same Area (unless Tie-Lines are used). Defining multiple Areas makes it possible to assign the same easily identifiable Source and Destination names (like VTR_1, VTR_2) for use by different devices at different locations in the facility.
Breakaway - A Take operation that switches a Source on at least one Level that is different from the Sources selected on the other Levels.
Channel - The communication path used to control the crosspoint group by the Router Control Engine over a selected protocol such as Serial or Ethernet paths.
Chop - A variation of a Take command that alternately connects each of two different Sources to a single Destination (flip-flopping) at a designated switching rate (the chop rate).
Note Encore 1.7.4 and earlier software does not support the Chop feature.
Crosspoint - An electronic switch that allows a signal to pass from an input to an output when the switch is closed.
Destination - The location to which Source signals are routed. A Destination may include one or more outputs across multiple Levels.
Exclusion Set - User-determined set of items excluded from control by a par-ticular control panel. Exclusion sets can be created for Areas, Destinations, Levels, or Salvos. An exclusion set may be shared by more than one panel.
Flag - A parameter that can be set in a control panel template to control how a panel operates.
Level - A grouping of signals of a particular type, such as digital video, audio right, audio left, Red, Green, or Blue, etc. This grouping becomes an independently controllable stratum of signals within a routing system.
Matrix - A configuration of potentially intersecting inputs and outputs. In routing switchers, a matrix is signal switching hardware configured such that any input may be switched to any output.
18 Encore — Control Panels Operation Manual
Routing Basics
Preset - Selecting an item (for example a Source or Destination) in prepara-tion for an action.
Protect - A control function that prevents control panels or devices from changing the current Source selection for the specified Destination.
Salvo - A named, system-wide preset which, when executed, can change crosspoints on multiple Destinations at the same time.
Source - An input signal or collection of input signals generally associated with a particular device (like a VTR or DDR). A Source may contain signals from multiple Levels.
Take - The direct, immediate switching of a different Source to a Destination. The Take occurs during the vertical interval for a clean transition.
Template - A set of parameters that can be applied to a control panel’s con-figuration. The same template can be applied to multiple panels.
Tally - A status acknowledgment returned to a control panel or terminal that an operation has been executed. Typically this will light up a button, but a Tally may report text (for example a Source name).
Tie-Line - A system tie-line is a physical connection used to give a Destina-tion connected to the output of one matrix access to Sources connected to the input of another matrix. A signal which passes through two or more matrices; more specifically the path (consisting of one or more Tie Wires) which links a Destination of one matrix to a Source of another matrix. A local tie-line is a special type that has Sources and Destinations in the same matrix, usually sending the signal out of the matrix for external processing.
Matrix Crosspoints and Levels DescriptionEach router matrix can be broken down into a number of switching matrices. A single switching matrix controls the switching (or routing) of a particular type of electrical signal (e.g. digital video, analog video, audio, data, etc.). These different signal formats are referred to as Levels. When a connection is made, a path is formed between a unique Source (logical grouping of physical inputs) and a unique Destination (logical grouping of physical outputs). The physical connection is accomplished using cros-spoint circuitry. Figure 9 illustrates how a single switching matrix operates.
Encore — Control Panels Operation Manual 19
Section 1 — Encore System Overview
Figure 9. A Single Switching Matrix
Outputs
8053
_15_
r0
Inputs0 1 2 3 4 5 6 7 8 9
0123456789
Any of the 10 inputs (numbered 0 to 9) can be routed to any of the 10 outputs (numbered 0 to 9). One input can also be routed to more than one output. All the possible routes are represented by the intersections of the horizontal and vertical lines in the illustration. The points where the lines meet (crosspoints) can be thought of as switches that allow the inputs to be connected to the outputs. In this example, three crosspoints are on (as indi-cated by the X symbols), and the following routes are made:
• Input 2 is routed to Output 1 and Output 4.
• Input 7 is routed to Output 6.
Sources and Destinations DescriptionSources consist of input signals to the router, and Destinations are output signals from the router. An individual Source or Destination may contain more than one signal. For example, a Source may consist of a video and a key signal; be separate Red, Green, and Blue video signals; or have a video signal and several associated audio signals. Each signal type is considered a Level. In general, a Source and Destination need to be configured with same number and type of Levels in order for Takes connecting them to be successful.
20 Encore — Control Panels Operation Manual
Routing Basics
Multi-Level Switching Description
All Level Take
An all Level Take switches the same input number on all Levels, to the con-trolled Destination, as shown in Figure 10.
Figure 10. Traditional All Level Take
Video Source A (VSA)
Audio Left Source A (ALSA)
Audio Right Source A (ARSA)
DVTR 1Source Devices Routing Matrix
Destination Device
Video Source B (VSB)
Audio Left Source B (ALSB)
Audio Right Source B (ARSB)
DVTR 2
Video Destination
Audio Left Destination
Audio Right Destination
DVTR 3
Audio Level
Video Level
VSA
ALSA
ARSA
VSB
ALSB
ARSB
VSA
ALSA
ARSA
8053
_06_
r0
Breakaway Take
A Breakaway Take is performed by selecting a Source different from the others (on at least one Level) to the controlled Destination. Breakaways allow a Destination to use different Sources (Figure 11).
Figure 11. Breakaway Take
Video Source A (VSA)
Audio Left Source A (ALSA)
Audio Right Source A (ARSA)
DVTR 1
Video Source B (VSB)
Audio Left Source B (ALSB)
Audio Right Source B (ARSB)
DVTR 2
Video Destination
Audio Left Destination
Audio Right Destination
DVTR 3
Audio Level
Video Level
VSA
ALSA
ARSA
VSB
ALSB
ARSB
VSA
ALSB
ARSB
8053
_07_
r0
Source Devices Routing Matrix
Destination Device
Encore — Control Panels Operation Manual 21
Section 1 — Encore System Overview
Tie-Line DescriptionTie-lines can be used to link different matrices, allowing Sources in one matrix to be routed to Destinations in another matrix. Each tie-line has a Source Name and a Destination Name that defines the signal path. A tie-line Source is actually a Destination of the first matrix, and the tie-line Des-tination is a Source of the second matrix. Routes that employ more than one tie-line are called multi-hop tie-lines (Figure 12).
Figure 12. Tie-Lines
Matrix 1Sources
8053
_42_
r0
Routing Matrix 1 Matrix 1Destinations
Tie-Line
Tie-Line
Tie-Line Source Name
Tie-LineSourceName
Tie-Line Source NameTie-Line Destination Name
Tie-Line Destination Name
Tie-LineDestinationName
Matrix 2Sources
(One Hop)
(Second Hop)(First Hop)Tie-Line
Routing Matrix 2 Matrix 2Destinations
Matrix 3Sources
Routing Matrix 3 Matrix 3Destinations
Once configured on an Encore system, actual tie-line operation is trans-parent to the operator. The Tie-Line Manager application automatically creates and releases tie-line paths as needed.
22 Encore — Control Panels Operation Manual
Section 2Control Panels Overview
Control Panel Hardware TypesAn Encore system supports many types of hardware control panels, several of which were originally developed for other routing systems.
Encore Control Panels• Paging Multi-Bus (PMB)
• Forty-Eight Button (48B)
• Button-Per-Source (BPS)
• XY Panel (XY)
• Universal Control Panel (ENC-UCP)
• Client Control Panel (ENC-CLNT)
SMS 7000 Control Panels• Eight Destination Paging (EDP)
• 48 Button-Per-Source (P48)
• Universal (UCP)
• Programmable Multibus 8 (MB8)
• Programmable Multibus 4 (MB4)
• 32 Button-Per-Source (P32)
• PXY Panel Group (PXS, PXD, PXYE)
• Simple Control Panel (SCP)
Note Legacy MCO and COS panels and a custom RIB interface are also supported by Encore 1.7.3 and newer software. These are not widely used and are not described in this manual.
Encore — Control Panels Operation Manual 23
Section 2 — Control Panels Overview
Kalypso Remote Aux Panels• KAL-32AUX1
• KAL-32AUX2
Acappella Control Panels• Several different hardware models, ranging from 16x16 to 8x1
Soft PanelsBesides hardware control panels, software emulations of control panels are also available. Soft Panels are virtual versions of physical control panels that can run on PCs connected to an Encore network. Soft Panels feature a Graphical User Interface (GUI) that represents the various specific panel types supported. Once configured, each Soft Panel type operates the same as the corresponding hardware panel. Soft Panels are sold separately from the Encore system and are individually licensed.
See the separate Encore Soft Panels Instruction Manual for more information.
Control Panel Communications InterfacesEncore, Acappella, and Kalypso panels use Ethernet and require the use of Ethernet switches and Cat 5 Ethernet cabling.
SMS 7000 control panels use Global Serial Channel (GSC) communications, and require installation of a GSC mezzanine in the Encore System Con-troller and 75 Ohm coaxial cabling for operation.
Refer to the separate Encore Installation and Service Manual for more infor-mation.
Control Panel SoftwareEncore control panels ship from the factory with Encore software installed and will be ready for network and operational configuration. You may need to update Encore control panel software to the latest version, how-ever, particularly if you use previously purchased Encore panels with your Encore system.
24 Encore — Control Panels Operation Manual
Control Panel Configuration
Control panels developed for other systems will need to have their soft-ware updated for use with Encore. These panels can then be configured using the Encore system OUI.
This manual, intended for operators, assumes the control panels being used have already been updated with the correct software and configured for operation. Software installation and upgrade procedures for specific Encore software releases are covered in the separate Encore Release Notes. Control panel configuration procedures are covered in the separate Encore Configuration Manual.
Control Panel ConfigurationThe configuration of a particular control panel defines how that panel behaves. For example, the panel configuration determines which Destina-tions and Levels a panel can control, which buttons perform which func-tions, and how the control panel accomplishes other operations.
Template files are available that can be used as a starting point for panel configuration. When a new control panel is added to an Encore system, it automatically receives configuration information from a default template for that type of panel. This configuration can then be saved with the name of that panel, and be modified to change the behavior of that panel. That configuration is then used by that control panel, unless it is modified or a different template file is loaded to that panel.
Some operations described in this manual may be limited by system or panel configuration constraints. Refer to the Encore Configuration Manual for system and control panel configuration instructions.
Control Panel Defaults (Factory and Facility)Encore systems ship with factory default control panel templates. This allows a control panel to be taken out of its box and used immediately.
Encore systems support different control panel default templates. The factory defaults cannot be edited by the user. Custom templates can be created for each type of panel, and you can specify these defaults are to be used when a new panel of that type is added to the Encore system.
Note Different Encore software versions may have factory panel default files with different settings, resulting in different behavior for new panels added to a system, depending on the version of Encore software being run.
Encore — Control Panels Operation Manual 25
Section 2 — Control Panels Overview
Factory Default Templates and AreasControl panel factory defaults are based upon the default Area (Area 1) configuration. Areas create hierarchies within the Encore Control System which makes it easier to group Sources and Destinations in a large system. The default Area is where control panels find their defaults. If Area 1 has been configured with Sources, Destinations, and Levels, then the control panels will operate using the Area 1 defaults. Once an Area is defined, an Area prefix is automatically assigned to each Source and Destination in the Area by the router engine. The Area prefix is part of the system name and can be displayed on certain panels. Typically, in most installations, a single Area is used.
If multiple Areas are used at a facility, some or all of the control panels may need to be re-configured before they can be used.
Control Panel Sign On Error MessagesAn Encore system Control Panel displays an error message if it fails to sign on to the Panel Server. These messages include:
• DUP_NAME - Duplicate name
• MAX_PNLS - Panel exceeds the maximum number
• UNKN_PNL - Unknown panel type
• SERV_ERR - Internal Server Error. The Panel Server failed to register the panel.
• OUI_EDIT - Same panel name is being edited in OUI
• PNL_NAME – Panel name length more than 8 characters
• NO_LICNS – None or insufficient licenses (Soft Panel only)
Control Panel Basic Functions
Protect and LockIn general, the Protect function (enabled/disabled during panel configura-tion) locks the Source selections for all the Levels of a Destination. When a Destination has been Protected by a panel, other panels in the facility will not be able to change that Destination’s Source selections (unless that other panel has been configured with a Protect Override). The panel which initi-ated the Protect can still be used to change Sources for a Destination that panel has protected, and that panel can also remove the protection from that Destination.
26 Encore — Control Panels Operation Manual
Control Panel Basic Functions
There are actually several different Protect and related Lock parameters that provide different capabilities that interact with each other. These include Hard Lock, Soft Lock, and Lock/Protect Override. The actual behavior of a specific panel depends on the setting of these parameters.
Refer to Section 8-Panel Operation Variations and the separate Encore Config-uration Manual for more information.
Salvos ExcludedSalvos can switch multiple Sources to multiple Destinations with a single button press. Default Encore panel configurations exclude all Salvos, to prevent accidentally changing multiple crosspoints on an existing Encore system when a new panel is installed.
The default setting for Encore control system panels excludes all Salvos. To use Salvos with a control panel, its configuration must be edited and re-loaded to that panel.
An AllSvos Salvo Set is available with v1.8.0 and newer Encore software that can make all Salvos available on a panel (hardware, Soft Panels, or RCL Cli-ents). With this setting selected, newly created Salvos are automatically added to this list, so a panel with this setting will always be able to execute any system Salvo.
Refer to the separate Encore Configuration Manual for specific instructions.
CAUTION Be sure you understand what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destinations with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.
ChopThe Chop feature allows two sources to be switched rapidly on a Destina-tion. The switching occurs between the current Source taken to that Desti-nation and a new Source selected for the Chop. This feature is useful for signal timing, camera matching etc.
The following matrices support the Encore Chop feature:
• Concerto (video only)
• Trinix (video only)
• Acappella (video only)
• 7500WB
Encore — Control Panels Operation Manual 27
Section 2 — Control Panels Overview
Chop is performed on a Level by Level basis, which means Breakaway Chop is available. Encore Level formats that support Chop for the above matrices are:
• Any (*)
• Composite (V)
• Component (C)
• Dig Video (D)
• SDi+Audio (E)
• Key (K)
Note Audio, Timecode, Data, and Other Levels do not support Chop.
All Encore system Control Panels support Chop except the CLNT/SVR and MCO/COS custom panels.
Chop Configuration
Encore system Control Panels need to be configured with Chop function-ality, using the Encore Control Panel Server OUI. Chop is activated on a Control Panel by making sure the Chop Lock flag is OFF (indicator is gray) in the Configuration Attributes and Flags menu and saving that configura-tion.
The rate at which the Sources will be switched during Chop is specified using the Encore Router Controller Application, by going to the Options menu and clicking on Chop Switch Rate. The valid range is 15 - 100 frames.
Refer to the separate Encore Configuration Manual for specific information.
Control Panel Chop Operation
1. Select the Destination for control that you wish to Chop. It cannot be Protected.
2. Press the Chop button so it illuminates.
3. Select an alternate Source from the same Area. That new Source and the original Source will be switched to that Destination at the specified switch rate, and CHOPPING will be reported on panels equipped with displays. On panels with dedicated Source buttons the button of the original Source will be high tally and the button of the chopping Source will blink (if the Flashing LED Indication flag is applied to the panel).
Note When Chop is active, selecting a different Source for that Destination on that Control Panel will Chop between that new Source and the original Source.
28 Encore — Control Panels Operation Manual
Control Panel Basic Functions
4. Press the illuminated Chop button to stop the Chop function. The original Source will be restored.
Take commands issued to a currently chopping Destination from any Panel stops the Chop function, and Takes that new Source to that Destination.
Chop Protect
A chopping Destination can be protected. Once protected, a chopping Des-tination must be unprotected before the Chop can be stopped.
Chop Limitations
The Chop feature Control Panel button tally correctly identifies the sources only on the local panel that initiated the Chop. The button for the original source will be high tally and the alternate chopping Source will blink (if the Flashing LED Indication flag is on that panel). A different Control Panel assigned to that Destination will report Chopping on its menu (if present) but will not blink the alternate Source’s button.
Changes made to Chop activity are not propagated across the Encore system. An unprotected chopping Destination can be altered to Chop to another source by a different Control Panel. If this occurs, the buttons on the panel that initiated the changed chopping Source will tally correctly, but the original panel will continue to blink the previous chopping Source (it will not change its tally status to reflect the new Source).
Control Panel Shift FunctionsShifted button functionality is available on all Encore system Control Panels except ENC-CLNT, SMS-CLNT, SMS-COS, SMS-MCO, and SMS-SVR. This feature allows a doubling of the number of functions available on a panel. For example, a BPS32 panel can be configured to access 64 Sources.
Shift Configuration
You will need to define the shifted button functions and add a Shift button to the panel’s configuration, using the Control Panel Server. Once config-ured, the Shift button goes high tally when the panel is in the shifted oper-ating mode.
Shift Operation
1. Press the Shift button on the panel so it is illuminated.
2. Press any button configured with a Shifted function. That function will immediately be performed.
Encore — Control Panels Operation Manual 29
Section 2 — Control Panels Overview
Destination Ganging
Background
Destination Ganging has been available for Encore 48B and JEP-100 Control Panels, as briefly described below.
• On 48B panels, holding down one Destination button and pressing and releasing others would Gang those Destinations, allowing Takes of the same Source to multiple Destinations with one button press. Selecting a Destination without holding down a button cancelled the Gang. This method can be considered Dest Ganging Option 1.
• On the JEP-100 Control panel, a front panel configuration setting could be used to activate Destination Ganging, at which time Destination buttons could be toggled on and off to add or remove them from a Gang. This can be considered Dest Ganging Option 2.
Destination Ganging Configuration for v1.8.0 Software
With Encore v1.8.0 and newer software, Destination Ganging functionality is added to the Encore BPS, SMS P32, P48, & PXS, and KMD & KSD Control Panels. Ganging Option 1 and Option 2 are both available on all these Control Panels, and on the Encore 48B panel. Option 2 Ganging becomes available on the Soft Panel equivalents for these panels, and continues to be available on the JEP-100 Control Panel.
If a hardware panel is configured with a Shift button, Ganging Option 1 is automatically disabled and only Ganging Option 2 will be supported. Because both the Shift and Ganging Option 1 features employ a button hold-down technique, they cannot both be active at the same time
Control panels that support both Destination Ganging options are config-ured with the Dest Ganging Option 2 flag, using the Encore Control Panel Server OUI. Refer to the separate Encore Configuration Manual for specific information.
Destination Ganging Operation
Ganging Option 1
1. Press and hold down a Destination button on the Control Panel.
2. Press and release other Destination buttons. They will illuminate, indicating they are included in the Gang. These buttons will blink if the Ganged Destinations currently route different Sources, and will be high tally if they all currently route the same Source.
3. Choose a Source. That source will be Taken to all the Destinations in the Gang.
30 Encore — Control Panels Operation Manual
Control Panel Basic Functions
Ganging Option 2
1. Toggle on the Destination buttons you wish to have in the Gang. Touching a Ganged Destination button removes it from the Gang.
2. Choose a Source. That source will be Taken to all the Destinations in the Gang.
Breakaway Takes and Ganging
Destination Ganging operations are applied to the currently enabled Levels, so breakaway Ganged Takes are supported.
Protect and Ganging• If a Protect or Lock is active on the primary ganged Destination,
attempts to create a Destination Gang will be ignored.
• If a Protect or Lock is active on an additional Destination, that destina-tion will not be added to the Gang.
• Protect or Lock conditions can also be applied (or removed) to all the destinations in a Gang.
Encore — Control Panels Operation Manual 31
Section 3Encore Control Panels
Introduction
Key Features• Web browser-based setup,
• 10/100Base-T Ethernet RJ-45 control interface, includes active and col-lision indication,
• Internal auto-ranging AC mains power supply,
• Back-lit buttons for use in low-light conditions with display intensity adjustments,
• Simple name-based identification, and.
• Chop (all Encore system Control Panels support Chop except the CLNT/SVR and MCO/COS custom panels).
Panel IDEncore panels equipped with alphanumeric displays can report the fol-lowing information for that panel (as appropriate).
• Panel IP Address
• Panel Name
• Controlled Destination Area Name
• Controlled Destination Name
• Name of the Current Active Level
• Protect Override, if set
• Tieline Name, if used
With default panel configurations, pressing the Dest/ID button on PMB and XY panels when these buttons are already illuminated, or holding down
Encore — Control Panels Operation Manual 33
Section 3 — Encore Control Panels
the TallyLvl/ID button on BPS panels, will activate the panel ID mode. On PMB and XY panels, pressing the Src button when it is illuminated reports additional information in the various displays on the panel.
You can interrupt the ID display sequence at any time by pressing a dif-ferent mode button. It is not necessary to let the identification routine finish. Pressing a button during the ID display does not execute that button’s function, but instead cancels the ID reporting.
PMB Panel
PMB Panel Features• 2RU rack mount,
• Multi bus display of both Source and Destination,
• Individual Protects per Destination,
• Paging mode offers the ability to scroll through pages of Sources, Des-tinations, Levels, and Salvos,
• Previous / Next scrolling within prefix group,
• 30 user-defined programmable buttons,
• 16 button user-defined prefix /suffix keypad, with shift capability to support up to 32 prefixes and suffixes,
• Dynamic page set creation, and
• Panel grouping, with the PMB acting as master panel with Encore 48B and/or Kalypso KSD expansion panels.
PMB Panel DescriptionThe PMB (Paging Multi-Bus) panel has a group of programmable buttons and a display for Preset and Level on the left, a programmable keypad in the center, and eight Status and Destination displays on the right (Figure 13).
34 Encore — Control Panels Operation Manual
PMB Panel
Figure 13. PMB Panel
Status 1
Des t inat ion 1
P reset
Leve l
Status 2
Des t inat ion 2
Status 3
Des t inat ion 3
Status 4
Des t inat ion 4
Status 5
Des t inat ion 5
Status 6
Des t inat ion 6
Status 7
Des t inat ion 7
Status 8
Des t inat ion 8
DestDest
IDID
LevelLevel SrcSrc
DestDestPagePage
LevelLevelPagePage
SrcSrcPagePage
SalvoSalvoPagePage
ChopChop
CECE
ClearClear
ShiftShiftA
PrevPrev NextNext
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
ProtProt
HoldHold
TakeTake
LoadLoad
Keypad Buttons (16)
Programmable Buttons (30)
Prev Next Prot/Hold (8) Take/Load (8)
Status and Destination Displays (8)Preset and Level Display
8053_02r1
PMB Panel Default Button AssignmentsThe default button configuration for the PMB panel is shown in Figure 14.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 14. PMB Panel, Default Button Configuration and Keypad Sets
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
PDR9PDR9
I
VTR1VTR1
J
VTR2VTR2
K
VTR3VTR3
L
VTR4VTR4
M
VTR5VTR5
N
VTR6VTR6
O
VTR7VTR7
P
DestDest
IDID
LevelLevel SrcSrc
DestDestPagePage
LevelLevelPagePage
SrcSrcPagePage
SalvoSalvoPagePage
ChopChop
CECE
ClearClear
ShiftShift
8053
_10r
0
Primary Keypad SetNotAssigned
ProgrammableFunction Buttons
Secondary Keypad Set
The Keypad is initially assigned the Default Keypad Sets, with the Primary keypad set active. To access the Secondary keypad set, press the Shift func-tion button.
Default panel configurations have the Chop feature inactive.
Taking a Source to a Destination (PMB Panel)The Take operation connects an incoming Source to an outgoing Destina-tion. The PMB panel is able to control multiple Destinations (statuses for
Encore — Control Panels Operation Manual 35
Section 3 — Encore Control Panels
eight Destinations are displayed simultaneously). You will choose which Destination you wish to change, preset the desired Source, and then perform the Take.
1. If the desired Destination is not already shown in one of the eight Status displays on the right, load that Destination to a status display.
a. Press the Dest/ID button to enter Destination mode.
b. Assign the desired Destination to the Preset display. You can either:
• Use the Prev or Next buttons (holding down the button to scroll), or,
• Enter the prefix and suffix with the keypad (if the panel config-uration supports this operation). With a prefix selected, you can use the Prev and Next buttons to scroll through the available items with that prefix, or you can use the keypad to enter suffix num-bers. The CE/Clear button is used to incrementally clear keypad entries.
c. Load that preset Destination to one of the Status displays on the right by pressing the Take/Load button for that display. These buttons are illuminated (and active) only when Preset has a valid item.
Note A panel’s configuration may exclude control of some Destinations or Levels. Excluded items will not be selectable in the Preset display.
2. Select the desired Source in the Preset display.
a. Press the Src button to enter Source mode.
b. Assign the desired Source to the Preset display (use the same procedure as Step b of Taking a Source to a Destination (PMB Panel) on page 35).
3. Press the Take/Load button on the Status display on the right for that Destination to take that preset Source. The name of the new Source will be displayed in that Destination’s status display.
Note If Destination and/or Source pages have been configured, the Dest Page and Src Page buttons can be used to browse successive groups of eight items.
Breakaway Take (PMB Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will preset the Destination, examine the status for that Destination’s Levels, select the Level(s) to be changed, select the Source, and then Take that Source to only those Destination’s Levels.
36 Encore — Control Panels Operation Manual
PMB Panel
Note Destinations with active breakaways display an asterisk (*) in their Destina-tion Status displays.
1. Assign the Destination on which you wish to perform a breakaway Take to the Preset display.
a. Press the Dest/ID button to enter Destination mode.
b. Assign the desired Destination in the Preset display (use the same procedure as Step b on page 36).
2. Press the Level Page button to enter Level mode. In this mode the Status displays on the right show the status of only the preset Destination (not eight different Destinations). The current Sources of each Level for that Destination are shown.
3. Illuminate the Take/Load buttons for only the Destination Levels you wish to change by toggling these buttons on or off. At least one Level must be selected.
4. Press the Src button to enter Source mode.
5. Assign the desired Source to the Preset display (use the same procedure as Step b on page 36).
6. Press the Take/Load button on the Status display on the right for the desired Destination. The name of the new Source will be displayed in that Destination’s status display and an asterisk will indicate it has a breakaway.
Note After setting up Levels for a breakaway, subsequent Take operations will change only those Levels for any currently selected Destination, not just the preset Destination.
Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations, until the Level selections are changed or a different Destination is selected.
Level Tally (PMB Panel)When a PMB panel displays the status of eight Destinations, each Destina-tion reports only one Source. When Destinations have multiple Levels and breakaways are active, you may wish to choose which Level’s Source will be reported for each Destination.
1. Press the Level button to go to Level status selection mode.
2. Use the Prev and Next buttons to cycle through the available Levels and leave the name of the desired Level displayed.
Note If ALLLVL is selected the panel will report the Default Tally Level configured for that panel.
Encore — Control Panels Operation Manual 37
Section 3 — Encore Control Panels
3. Press the Src button to return to Source mode. Now Sources for the Level you selected will be reported on the Destination Status displays.
Protect (PMB Panel)
Note With default panel configurations, only the control panel that set the Protect can unprotect that Destination. When a Protect has been set, the Prot button on the panel that set the Protect will blink, and the Prot buttons on other panels accessing that Destination will be illuminated without blinking.
Note Pressing and holding a steadily illuminated Prot button on a panel with a text display will report the name of the panel that set the Protect.
To Protect a Destination
1. If the desired Destination is not already shown in one of the eight Status displays on the right, load that Destination to a status display (use the same procedure as Step 1 on page 36).
2. Press the Prot button located to the right of the Status display for the Destination you wish to Protect. The Prot button will blink on that panel. The Prot buttons will also illuminate steadily on all other Encore panels in your system with that Destination selected, indicating it is protected.
To Unprotect a Destination
1. If the desired Destination is not already shown in one of the eight Status displays on the right, load that Destination to a status display (use the same procedure as Step 1 on page 36).
2. Toggle the blinking Prot button so it is no longer illuminated.
Note PMB panels do not report Protects for Destinations not currently assigned to the Status displays. Care should be taken to relinquish all unneeded Protects before changing Destinations on these panels. You should also remember to free up all Destinations no longer requiring protection before you leave the vicinity of the PMB panel.
Salvo (PMB Panel)When a PMB panel has been configured with Salvo capabilities, you will be able to select a Salvo and execute it.
38 Encore — Control Panels Operation Manual
PMB Panel
CAUTION Be sure you understand exactly what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destina-tions with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.
1. Press the Salvo Pg button to enter Salvo mode. The first page of available Salvos will be displayed in the Status displays on the right.
2. If multiple pages of Salvos have been configured, use the Prev and Next buttons to move through the available pages of Salvos.
3. When the desired Salvo is displayed, press the Take/Load button on that Status display to execute the Salvo.
4. Press the Src button to return to Source mode. If Destinations involved in that Salvo are displayed, their Status displays will report their new Sources.
Dynamic Page Set CreationEncore PMB Control Panels (and also SMS EDP, MB8, and MB4 Control Panels) support Dynamic Destination Page Creation. This feature allows the user to create a new Destination Page Set using the Control Panel front panel buttons.
Dynamic Page Set Panel Configuration
The panel needs to have a Store button configured as one of its program-mable buttons. The Encore Panel Server OUI is used for panel configura-tion. Refer to the separate Encore Configuration Manual for specific instructions.
Dynamic Page Set Operation
1. Place the Control Panel in Destination Mode (by pressing the Dest button), preset a Destination you wish to use in the new Page Set (by scrolling, and assign it to a Status and Destination display on the right. The Store button will illuminate.
2. Repeat Step 1 above for all the Destinations you wish to change in that Page Set.
3. Press the Store button. A new Destination Page named DynPG(n) will be created and a new Page Set named PgSet(n) is also created that includes that new Destination Page. The new Destination Page and Page Set are also available for use on any other Control Panel supporting this feature, by configuring that panel with the Panel Server OUI.
Encore — Control Panels Operation Manual 39
Section 3 — Encore Control Panels
XY Panel
XY Panel Features• 1RU rack mount,
• Status, Preset, and Level display with three 8-character readouts,
• 16 button programmable keypad (2 rows of eight), and
• 18 programmable buttons, 10 on the left and 8 on the right.
XY Panel DescriptionThe XY panel’s name represents the fact that all inputs (X) mapped to the panel are available to all outputs (Y) mapped to that panel. The XY panel has a display for Status, Preset and Level, a programmable keypad, and two groups of programmable buttons on the far left and right (Figure 15).
Figure 15. XY Control Panel
Status
Preset
Leve l
DestDest
IDID
ChopChop
SrcSrc
CECE
ClearClear
SalvoSalvo
PrevPrev
LevelLevel
NextNext
ProtProt
TakeTake
8053_12r1
Programmable Keypad Buttons (16)
Programmable Buttons (10) Programmable Buttons (8)Status, Preset, and Level Display
XY Panel Default Button AssignmentsThe default function and selection button configuration for the XY panel is shown in Figure 16.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 16. XY Default Button Configuration
8053
_13r
0
DestDest
IDID
ChopChop
SrcSrc
CECE
ClearClear
SalvoSalvo
PrevPrev
LevelLevel
NextNext
ProtProt
TakeTake Destination 1 toDestination 4
Source 1 toSource 4
Default Function Buttons(10 Buttons on Left)
Default Selection Buttons(8 Buttons on Right)
40 Encore — Control Panels Operation Manual
XY Panel
The default Keypad set for the XY panel is shown in Figure 17.
Figure 17.
AUXAUX
9
BARSBARS STUSTU
0
BLACKBLACK
8
CAMCAM
CARTCART
CGCG
4
FSFS
NETNET
3
PDRPDR
2
REMREM ENGENG
5
VCRVCR
6
EDITEDIT
7
testtest
VTRVTR
1
8053
_14r
0
XY Default Keypad Configuration
Status Display Reporting of Source and DestinationThe state of one Destination at a time can be reported in the XY panel status display. The display can also report Source and Destination names for the dedicated XY panel buttons.
• When a dedicated Destination selection button is pressed and released so it is illuminated, the name of the current Source for that Destination is shown in the status display.
• Holding down a dedicated Destination button displays the name of that Destination. This lets you confirm the panel’s Destination button configuration before use.
• When a non-dedicated Destination has been loaded to the Preset dis-play, pressing the Src button to go to Source mode will make the Status display report the name of the current Source for that Destination.
Taking a Source to a Destination (XY Panel)The Take operation connects an incoming Source to an outgoing Destina-tion. An XY panel can switch any Source to any Destination (provided the panel’s configuration has not excluded them from control). XY panels can also be configured with dedicated Source and Destination buttons.
Using Dedicated Destination and Source Buttons
If the XY panel has buttons dedicated for the Destination and Source you wish to connect, simply touch the Destination button so it is illuminated, then touch the desired Source button. The name of the new Source will be reported in the status display.
Switching Non-Dedicated Sources to Destinations
Destinations not mapped to XY panel buttons will need to be loaded to the preset display. You then select a Source and perform the Take.
Encore — Control Panels Operation Manual 41
Section 3 — Encore Control Panels
Note A panel’s configuration may exclude control of some Destinations and Levels. Excluded items will not be selectable in the Preset display.
1. Press the Dest/ID button to enter Destination mode.
2. Assign the desired item to the Preset display. You can either:
• Use the Prev or Next buttons (holding down the button to scroll), or,
• Enter the prefix and suffix with the keypad (if the panel configura-tion supports this operation). With a prefix selected, you can use the Prev and Next buttons to scroll through the available items with that prefix, or you can use the keypad to enter suffix numbers. The CE/Clear button is used to incrementally clear keypad entries.
3. Load that Destination to preset by pressing the Take button. The name of that Destination will be reported in the display.
4. Press the Src button to enter Source mode.
5. Select the desired Source on the preset display (use the same procedure as Step 2 above).
6. With the name of the desired Source displayed, press the Take button. The connection will be made and the name of the new Source will be reported in the status display.
Note If the desired Source is mapped to an XY panel button, pressing that button in Source mode with the Destination preset will simultaneously select that Source and perform the Take.
Breakaway Take (XY Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will preset the Destination, select the Level(s) to be changed, select the Source, and then Take that Source to only those Destination’s Levels.
Note A Destination with an active breakaway displays an asterisk (*) in the Status display.
1. Assign the Destination on which you wish to perform a breakaway Take to the Preset display (see Step 1 through Step 3 of Switching Non-Dedicated Sources to Destinations on page 42).
2. Press the Level button to enter Level mode. In this mode you use the Prev and Next buttons to cycle through the available Levels for that Destination.
3. Illuminate the Take button for only the Destination Levels you wish to change by toggling the button on or off as you cycle through the Levels with the Prev and Next buttons. At least one Level must be selected.
42 Encore — Control Panels Operation Manual
XY Panel
4. Press the Src button to enter Source mode.
5. Select the Source for the breakaway Take, using the same procedure as Step 2 of Switching Non-Dedicated Sources to Destinations on page 41).
6. Press the Take button. The new Source will be connected to only the selected Levels and an asterisk will appear in the Status display to indicate it has a breakaway.
Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations, until the Level selections are changed or a different Destination is selected.
Protect (XY Panel)
Note With default panel configurations, only the control panel that set the Protect can unprotect that Destination. When a Protect has been set, the Prot button on the panel that set the Protect will blink, and the Prot buttons on other panels accessing that Destination will be illuminated without blinking.
Note Pressing and holding a steadily illuminated Prot button on a panel with a text display will report the name of the panel that set the Protect.
With the desired Destination selected, either by pressing its dedicated Des-tination button or assigning it to the Preset display, toggle the Prot button to turn Protect On (illuminated) or Off for that Destination.
Note XY panels do not report Protects for Destinations not currently assigned to the Status display. Relinquish all unneeded Protects before changing Desti-nations on these panels. Also remember to free up all Destinations no longer requiring protection before you leave the vicinity of the XY panel.
Salvo (XY Panel)When an XY panel has been configured with Salvo capabilities you will be able to select a Salvo and execute it.
CAUTION Be sure you understand exactly what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destina-tions with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.
1. Press the Salvo button to enter Salvo mode.
2. Use the Prev and Next buttons to move through the available pages of Salvos.
3. When the desired Salvo is displayed, press the Take button on that Status display to execute the Salvo.
Encore — Control Panels Operation Manual 43
Section 3 — Encore Control Panels
BPS Panel
BPS Panel Features• 1RU rack mount,
• Eight character Destination Status display,
• 42 user-defined programmable buttons, and
• Panel self configuration for alternative Source selection.
BPS Panel DescriptionThe BPS panel has a Destination Status Display on the left and two groups of programmable buttons (Figure 18).
Figure 18. BPS Control Panel
Des t inat ion Status
ProtProt
Lvl 1Lvl 1
ChopChop
Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 6Lvl 6Lvl 4Lvl 4
PrevPrev
All LvlsAll Lvls
ConfigConfig
TallyTally
IDID
Lvl 5Lvl 5
NextNext
Selection Buttons (32)Function Buttons (10)All Buttons Programmable
(typical configuration shown)
Destination Status Display
8053_16r0
BPS Panel Default Button AssignmentsThe default function and selection button configuration for the BPS panel is shown in Figure 19.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 19. BPS Default Button Configuration
ProtProt
Lvl 1Lvl 1
ChopChop
Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 6Lvl 6Lvl 4Lvl 4
PrevPrev
All LvlsAll Lvls
ConfigConfig
TallyTally
IDID
Lvl 5Lvl 5
NextNext
Right 32 Buttons Default Configuration Top Row: Source 1 - 16
Bottom Row: Source 17 - 32
8053
_17r
0
44 Encore — Control Panels Operation Manual
BPS Panel
Default BPS Single Destination OperationThe default configuration for a BPS panel limits the scope of its control to a single Destination. For example, this panel can be dedicated to control inputs to a particular VTR. Operating procedures for the default single Des-tination configuration are be described in this section.
BPS panels are not limited to single Destination control, however. All of the buttons on the BPS panel can actually be programmed for any function or Source selection (except these panels do not support keypads). This makes it possible to configure a BPS panel with capabilities similar to an XY panel, except it will lack a keypad and have limited status reporting.
Taking a Source to a Destination (BPS Panel)On a default single Destination BPS, Sources are selected by pressing the desired Source selection button on the right. The Source is immediately taken to that Destination and the name of that Source is reported in the Des-tination Status display.
Breakaway Take (BPS Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will select the Level(s) to be changed, then Take that Source to only those Destination’s Levels.
Note A Destination with an active breakaways displays an asterisk (*) in the Status display.
1. Toggle the Lvl buttons to illuminate the Levels of that Destination you wish to change.
2. Press the desired Source selection button. That Source will be taken to only the selected Levels, and an asterisk will appear in the Status display to indicate it has a breakaway.
Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations until the Level selections are changed or a different Destination is selected.
Protect (BPS Panel)
Note With default panel configurations only the control panel that set the Protect can unprotect that Destination. When a Protect has been set the Prot button on the panel that set the Protect will blink, and the Prot buttons on other panels accessing that Destination will be illuminated without blinking.
Encore — Control Panels Operation Manual 45
Section 3 — Encore Control Panels
Note Pressing and holding a steadily illuminated Prot button on a panel with a text display will report the name of the panel that set the Protect.
Toggle the Prot button to turn Protect On (illuminated) or Off for that Des-tination.
Salvo (BPS Panel)The default configuration for a BPS panel does not include any Salvo but-tons. If your panel has been configured for this feature a Salvo is fired simply by pressing the Salvo button configured for this purpose.
Self Configuration (BPS Panel)More than 32 Sources can be accessed by the BPS panel using the Self Con-figuration feature. This features allows BPS panel buttons to be remapped using the panel itself. BPS panel Level and Salvo buttons can also be self configured.
The normal reconfiguration process (using the Encore Panel Server appli-cation running on a PC to edit that panel’s configuration file) is not required to make these changes. The changes made with the Self Configu-ration are saved to that panel’s configuration file when the mode is exited and are persistent. Resetting a BPS panel after a Self Configuration will not change those settings.
The BPS panel default has the Self Configuration feature enabled. This feature can be disabled and so may not be available on a specific BPS panel.
Source Self Configuration
1. Press and hold down the All Lvls/Config button for five seconds. The panel will enter Self Configuration mode and all the Source selection and Level buttons will be illuminated.
2. Press an illuminated Source button. That button will blink.
3. Use the Prev and Next buttons to select a different Source for that button.
4. Press the blinking Source button to assign it that new Source.
5. Press the All Lvls/Config button to exit Self Configuration mode.
Level Self Configuration
Use the procedure above, but press an illuminated Lvl button and then choose an alternative Level with the Prev and Next buttons.
46 Encore — Control Panels Operation Manual
48B Panel
Salvo Self Configuration
If your panel is configured with Salvo selection buttons use the procedure above, but select an illuminated Salvo button and then choose an alterna-tive Salvo with the Prev and Next buttons.
48B Panel
48B Panel Features• 1RU rack mount,
• 48 user defined buttons,
• Default X-Y functionality, program row of Sources and row of Destina-tions,
• Allows Destination ganging (ideal for tape duplication), and
• Grouping with other panels to expand functionality.
48B Panel DescriptionThe 48B (Forty-Eight Button) panel only has programmable buttons and does not have an alphanumeric display (Figure 20).
Figure 20. 48B Control Panel and Default Button Configuration
Source 1 to Source 24
Tally Level
8103_00_38r0
Destination 1 to Destination 19 Level 1 to Level 4
48B Panel Default Button AssignmentsThe default function and selection button configuration for the 48B panel is shown in Figure 20.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Encore — Control Panels Operation Manual 47
Section 3 — Encore Control Panels
Taking a Source to a Destination (48B Panel)1. Press the desired Destination button so it is illuminated.
2. Press the desired Source button. That Source will be immediately taken to that Destination.
Breakaway Take (48B Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will select the Level(s) to be changed, then Take that Source to only those Destination’s Levels.
1. Press the desired Destination button so it is illuminated.
2. Toggle the Lvl buttons to illuminate the Levels you wish to change.
3. Press the desired Source button. That Source will be immediately taken only to the selected Levels of that Destination.
Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations until the Level selections are changed or a different Destination is selected.
Auto Tally and the Tally Level ButtonThe Auto Tally feature automatically tallies the first valid and enabled Level for a Destination. This is useful for breakaway Takes on panels lacking alphanumeric displays, since only one Source button is illuminated at a time. The Auto Tally configuration flag can be turned on and off, and the factory default setting for this feature is ON for 48B panels. When Auto Tally is ON, the Tally Level button, if present on a panel, is disabled.
You can Tally the Source for each Level of a Destination when Auto Tally is ON by disabling the other Levels. The Source button for that remaining enabled Level will be illuminated on the panel.
The priority order of Tally Level reporting when multiple Levels are active is the top down order of Levels in the router configuration. Typically this top down priority order corresponds to a left right order of Level buttons on a panel (Level 1, Level 2, Level 3, etc.). So, for example, if only Levels 2 and 3 are enabled and they are listed in that top down order, Auto Tally would illuminate the Source button for Level 2. Disabling Level 2 in this sit-uation would make the Source button for Level 3 illuminate.
48 Encore — Control Panels Operation Manual
48B Panel
Tally Level Button
The Tally Level button is used to change the Tally Level for the panel. Only the currently selected Level will be tallied.
Note On 48B panels the default setting for Auto Tally flag is ON, which disables the Tally Level button. Make sure Auto Tally is OFF on the configuration being used by the panel if you wish to use the Tally Level button.
Turning the Auto Tally flag OFF activates the Tally Level button, which is assigned to the lower right button by the factory default configuration (see Figure 20 on page 47).
To change the Tally Level of the panel, hold down the Tally Level button and press the Level button of the desired Level. The panel will use that Level for button tally until another Level is selected (or the Auto Tally flag is enabled).
Protect (48B Panel)The default configuration for a 48B panel does not include a Protect button. If your panel has been configured for this feature you can protect and unprotect the currently selected Destination by toggling the Prot button On or Off. The button is illuminated when a Protect is active on the selected Destination.
Salvo (48B Panel)The default configuration for a 48B panel does not include any Salvo but-tons. If your panel has been configured for this feature a Salvo is fired simply by pressing the Salvo button configured for this purpose. Salvo pages are not supported on 48B panels. A separate Salvo button is config-ured for each specific Salvo.
Encore — Control Panels Operation Manual 49
Section 3 — Encore Control Panels
Universal Control Panel (ENC-UCP)
ENC-UCP Panel Features• 2RU half-rack mount,
• Status, Preset, and Level display with three 8-character readouts,
• 16 button programmable keypad (4 rows of four),
• Prev and Next buttons,
• 12 programmable buttons on the left,
• Two looping RS-485 ports with RJ-45 connectors (for Jupiter control using MPK protocol), and
• Server panel operation with Encore Client control panels (see page 52).
ENC-UCP Panel DescriptionThe ENC-UCP panel functions the same as the Encore XY panel, except for fewer programmable buttons, different button locations, and a different half-rack form factor (Figure 15).
Figure 21. ENC-UCP Control Panel
NextNextPrevPrev
SRCSRC
LocalLocal
ChopChop
TakeTakeAllAl l
LevelLevel
Fi l terFi l ter
ProtProt
TakeTake
SalvoSalvo
ShiftShift
DestDest
IDID
CE CE
ClearClear
UNIVERSAL CPUNIVERSAL CP ENCORE/PRELUDE ENCORE/PRELUDEStatusStatus
PresetPreset
Dest /Leve l /AreaDest /Leve l /Area
8053_40r2
Keypad Buttons (16)
Status, Preset, and Level Displays
2-RU Rack Mount Frame (holds two half-rack units)
Programmable Buttons (30)
ENC-UPC Panel Default Button AssignmentsThe default function and selection button configuration for the ENC-UCP panel is shown in Figure 16. The Prev and Next buttons have fixed functions not configurable by the user.
50 Encore — Control Panels Operation Manual
Universal Control Panel (ENC-UCP)
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 22. ENC-UCP Default Button Configuration
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
PDR9PDR9
I
VTR1VTR1
J
VTR2VTR2
K
VTR3VTR3
L
VTR4VTR4
M
VTR5VTR5
N
VTR6VTR6
O
VTR7VTR7
P
DestDest
IDIDLevelLevel SRCSRC
SalvoSalvo
ShiftShift
FilterFilter LocalLocal
ProtProt
CECE
ClearClearTakeTake
8053
_41r
1
Primary Keypad SetProgrammableFunction Buttons
Secondary Keypad SetNotAssigned
ENC-UCP Standalone OperationWhen not configured as a Server/Client group, the ENC-UCP panel oper-ates the same as the Encore XY panel, but with relocated buttons. Refer to XY Panel on page 40 for operating instructions.
Encore — Control Panels Operation Manual 51
Section 3 — Encore Control Panels
Client Control Panel (ENC-CLNT)
Figure 23. ENC-UCP (Left) and ENC-CLNT (Right) Control
NextNextPrevPrev
SRCSRC
LocalLocal
ChopChop
TakeTakeAllAl l
LevelLevel
Fi l terFi l ter
ProtProt
TakeTake
SalvoSalvo
ShiftShift
DestDest
IDID
CE CE
ClearClear
UNIVERSAL CPUNIVERSAL CP ENCORE/PRELUDE ENCORE/PRELUDEStatusStatus
PresetPreset
Dest /Leve l /AreaDest /Leve l /Area
LoadLoad
ProtProt
TakeTake
1
2
2
CLIENT CONTROL PANELCLIENT CONTROL PANEL ENCORE/PRELUDE ENCORE/PRELUDE
3
4
5
6
LoadLoad
ProtProt
TakeTake
1
2
23
4
5
6
LoadLoad
ProtProt
TakeTake
1
2
23
4
5
6
8053_46
UCP Panel Configured as ServerClient Panel
Destination Displays & Keypads (3)
2-RU Rack Mount Frame (holds two half-rack units)
Panels
The ENC-UCP panel can be configured to act as a Server panel. Server and Client Control Panels fill a unique operational niche. The panels are com-plementary. The Server Panel provides quick keypad access to as many as 32 Source and Destination prefixes and suffixes, and Prev/Next scrolling access to all non-excluded system Sources and Destinations. Preset Source names are sent to Client Panels and stored in registers for convenient one-button recall or immediate use. A single Server Panel can be associated with up to 15 Client Panels within a single Client Server Group. Each Client Panel controls three Destinations. Thus, a single Server Panel can be used to set up six Source presets, each for up to forty-five router Destinations. Each preset could include Sources on up to 32 control Levels.
ENC-CLNT ConfigurationTo configure Encore Server Client control panels, the Server is identified as a Master panel, and each Client panel is configured as a member of that master panel’s group. Default Destinations are then assigned to the three Client panel sections using the Default Dst/Page flag.
See the separate Encore Installation & Service Manual for specific configura-tion instructions.
ENC-CLNT Operation
Note If the Client panel is reset, any assigned Destinations are replaced by default Dest/ Page settings, and all Sources are cleared from the numbered buttons.
52 Encore — Control Panels Operation Manual
Client Control Panel (ENC-CLNT)
Changing Destinations on a Client Panel
If you do not want to use a Client panel’s default Destinations, they can be changed with the Server panel.
1. Push Dest/ID on the Server panel to put it into Destination mode.
2. Preset a Destination on the Server panel, using the keypad or the Prev and Next buttons.
3. Press the Load button of the Client panel section you wish to assign that Destination to.
Identifying Assigned Client Panel Destinations
When the Server panel is in Destination mode, pressing the CE/Clear button clears the preset. The three currently assigned Destinations will be reported on those displays.
Assigning Sources to Client Panel Buttons
Once a Server Client panel group is configured, you can preset a Sources on the Server panel and assign them to buttons on the Client panel.
1. Push SRC on the Server panel to put it into Source mode.
2. Preset a Source on the Server panel, using the keypad or the Prev and Next buttons.
3. Press a Client panel section’s Load button, and then press a numbered button (1 - 6). Up to six Sources can be dynamically associated with those buttons for each Client Destination keypad.
Identifying Client Panel Sources
When the Server panel is in Source mode, pressing the CE/Clear button clears the preset. The three Sources for the currently assigned Destinations will be reported on those displays.
Taking a Source to a Destination (CLNT Panel)
To Take a Source to a Destination, touch the numbered register button (1-6), and then touch the blinking Take button on that Destination’s Client panel keypad.
Note Single button Takes is also available on Client panels (see Quick Take Mode below).
Encore — Control Panels Operation Manual 53
Section 3 — Encore Control Panels
Quick Take Mode
A Client panel can be configured for Quick Take mode, by checking this box in the Encore Panel Server Flags and Parameters page for that Client panel. In this mode, pressing a numbered Source button will immediately perform a Take of that Source to that Client panel sections’s Destination.
In this mode, the Protect button changes its function. Pressing this button allows identification of the Source on each keypad button (by pressing that button). Once you have confirmed it is the correct Source, press the Protect button to exit the identification mode, and then press Take or press the blinking button to take that Source to that Destination.
Because the Client panel’s Protect button is unavailable in this mode, Take performed by the Client panel is automatically protected. If you wish to unprotect one of these Destinations, you can use the Encore OUI, or use another panel configured for Protect override.
54 Encore — Control Panels Operation Manual
Section 4SMS7000 GSC Control Panels
IntroductionSMS7000 Global Serial Channel (GSC) control panels can be used with an Encore version 1.7 or higher system. The control panel’s internal software needs to updated for use with Encore and a GSC mezzanine must be installed in the Encore System Controller. SMS7000 GSC control panels connect to Encore via the GSC BNC connectors on the rear panel of the Encore System Controller frame. Each of the four GSC busses support up to 16 SMS7000 control panels for a total of 64 per Encore System Controller.
Because the GSC panels do not use Ethernet these panels are not visible to the Grass Valley NetConfig application. GSC panel software cannot be updated using NetConfig, but instead a PC and a direct serial connection are used. See the Encore Release Notes for the latest installation and software update procedures.
Once installed with the Encore software, GSC panels are configured the same as other Encore panels, using the Encore Panel Server application. See the Encore Configuration Manual for additional information.
In general, SMS7000 panel functionality under Encore does not mimic func-tionality under SMS7000 control; rather it is based on the existing function-ality of the equivalent Encore control panel type.
All Encore system Control Panels support Chop except the CLNT/SVR and MCO/COS custom panels.
Because the GSC panels use older hardware and communication methods, their operating response will be slower than newer Encore control panels.
Encore — Control Panels Operation Manual 55
Section 4 — SMS7000 GSC Control Panels
UCP Panel
UCP Panel Features• 2RU half-width rack mount,
• Status, Preset, and Level alphanumeric displays,
• Access to all Destinations and Sources,
• 26 programmable buttons,
• 16 button user-defined prefix /suffix keypad, and
• Previous / Next scrolling within prefix group.
UCP Panel DescriptionThe UCP (Universal Control Panel) has a group of programmable buttons on the left, three alphanumeric displays in the center, and a programmable keypad on the right (Figure 24).
Figure 24. UCP - Universal Control Panel
8053_20r0
STATUSRemt 3
PRESETRemt 3
LEVELRemt 3
DESTID
LEVEL SRC
PREVSALVO NEXT
CECLEAR
PROT
TAKE
CHOP
UCP Panel Default Button AssignmentsThe default button configuration for the UCP panel is shown in Figure 25.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
56 Encore — Control Panels Operation Manual
UCP Panel
Figure 25. UCP Panel, Default Button Configuration and Keypad Sets
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
PDR9PDR9
I
VTR1VTR1
J
VTR2VTR2
K
VTR3VTR3
L
VTR4VTR4
M
VTR5VTR5
N
VTR6VTR6
O
VTR7VTR7
P
DESTDESTIDID
LEVELLEVEL SRCSRC
SALVOSALVO PREVPREV NEXTNEXT
PROTPROT CHOPCHOP
TAKETAKE
CECECLEARCLEAR
8053
_21r
0
Primary Keypad SetProgrammableFunction Buttons
Secondary Keypad Set
The Secondary Keypad set will only be available on the panel if the default configuration is changed to include a Shift button.
Note The PREV and NEXT buttons are not equipped with LEDs and so will not tally if programmed for a different function.
Taking a Source to a Destination (UCP Panel)1. Press the DEST/ID button to enter Destination mode.
2. Use the PREV and NEXT buttons to show the desired Destination on the Preset display.
3. Press the TAKE button to assign that Destination to the Status display.
4. Press the SRC button to enter Source mode.
5. Use the PREV and NEXT buttons to show the desired Source on the Preset display.
6. Press the TAKE button. The new Source is taken to that Destination and that Source’s name is reported in the status display.
Note A panel’s configuration may exclude control of some Sources, Destinations, and Levels. Excluded items will not be selectable in the Preset display.
Breakaway Take (UCP Panel)1. Press the DEST/ID button to enter Destination mode.
2. Use the PREV and NEXT buttons to show the desired Destination on the Preset display.
3. Press the TAKE button to assign that Destination to the Status display.
Encore — Control Panels Operation Manual 57
Section 4 — SMS7000 GSC Control Panels
4. Press the LEVEL button to enter Level mode.
5. Use the PREV and NEXT buttons to show each Level in turn on the Level display. Press the TAKE button so it is illuminated to select the Levels you wish to change for that Destination. At least one Level must be selected.
6. Press the SRC button to enter Source mode.
7. Use the PREV and NEXT buttons to show the desired Source on the Preset display.
8. Press the TAKE button. The new Source is taken only on the selected Levels of that Destination.
Protect (UCP Panel)
Note With default panel configurations, only the control panel that set the Protect can unprotect that Destination. When a Protect has been set, the PROT button on the panel that set the Protect will blink, and the PROT buttons on other panels accessing that Destination will be illuminated without blinking.
Note Pressing and holding a steadily illuminated PROT button on a panel with a text display will report the name of the panel that set the Protect.
1. Press the DEST/ID button to enter Destination mode.
2. Use the PREV and NEXT buttons to show the desired Destination on the Preset display.
3. Toggle the PROT button to turn Protect On (illuminated) or Off for that Destination.
Note UCP panels do not report Protects for Destinations not currently assigned to the Status display. Care should be taken to relinquish all unneeded Protects before changing Destinations on these panels. You should also remember to free up all Destinations no longer requiring protection before you leave the vicinity of the panel.
Salvo (UCP Panel)When a UCP panel has been configured with Salvo capabilities, you will be able to select a Salvo and execute it.
CAUTION Be sure you understand exactly what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destina-tions with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.
1. Press the SALVO button to enter Salvo mode.
58 Encore — Control Panels Operation Manual
CLNT Panel
2. Use the PREV and NEXT buttons to show the desired Salvo on the Preset display.
3. Press the TAKE button to fire the selected Salvo.
CLNT PanelThe SMS-7000 Client panel is available for use as a member of a group with an SMS-7000 UCP configured as a Server (Figure 26).
Figure 26. UCP and CLNT Control Panel Group
8053_55r0
Grass Valley
PRESETRemt 3
LEVELRemt 3
DESTID
LEVEL SRC
PREVSALVO NEXT
CECLEAR
SHIFT
TAKEALL
CHOP
Grass Valley
Remt 3
LOAD 4
PROT 5
TAKE 6
1
2
3
LOAD 4
PROT 5
TAKE 6
1
2
3
LOAD 4
PROT 5
TAKE 6
1
2
3
Remt 3 Remt 3
Series 7000
Series 7000
The configuration and operation of this panel is similar to the Encore UCP/CLNT group. Refer to Client Control Panel (ENC-CLNT) on page 52.
P32 Panel
P32 Panel Features• 1RU rack mount,
• Alphanumeric status display, and
• 36 user-defined programmable buttons.
P32 Panel DescriptionThe P32 (Programmable 32 button) panel was originally designed to control the routing of a limited number of Sources to a single Destination with a single button press. The default configuration has a minimal number of function buttons on the left, a single alphanumeric display, and Source selection buttons on the right (Figure 27).
Encore — Control Panels Operation Manual 59
Section 4 — SMS7000 GSC Control Panels
Figure 27. P32 - Programmable Button-Per-Source Control Panel
8053_24r0
Bobs Cam
SRCID
LEVELINV
PROT
CHOP
Under Encore control all the P32 panel buttons can be programmed for dif-ferent functions or Source selections, including the selection of Destina-tions. This section describes only the panel’s default behavior of controlling a single Destination.
P32 Panel Default Button AssignmentsThe default button configuration for the P32 panel is shown in Figure 28.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 28. P32 Panel, Default Button Configuration and Keypad Sets
SRCSRCIDID
PROTPROT
CHOPCHOP LEVELLEVELINVINV
8053
_25r
0
Right 32 Buttons Default ConfigurationTop Row: Source 1-16
Bottom Row: Source 17-32
ProgrammableFunction Buttons
Taking a Source to a Destination (P32 Panel)Press the button for the desired Source. It will immediately be taken to the Destination and the name of the Source appears in the status display.
Breakaway Take (P32 Panel)1. Press the LEVEL/INV button to enter Level mode. In this mode the buttons
on the right no longer select Sources. The first upper row buttons now correspond to the Levels available and will be illuminated when they have been selected.
2. Press the selection buttons to toggle the desired Levels On or Off.
Note Pressing the LEVEL/INV button when it is illuminated will swap the Level selections (On Levels go Off, and Off Levels go On).
60 Encore — Control Panels Operation Manual
MB8 Panel
3. Press the SRC/ID button to enter Source mode.
4. Press the desired Source button. The new Source is taken only to the selected Levels of that Destination.
Protect (P32 Panel)Toggle the PROT button to turn Protect On (illuminated) or Off for that Des-tination.
Note With default panel configurations only the control panel that set the Protect can unprotect that Destination. When a Protect has been set the PROT button on the panel that set the Protect will blink, and the PROT buttons on other panels accessing that Destination will be illuminated without blinking.
Note Pressing and holding a steadily illuminated PROT button on a panel with a text display will report the name of the panel that set the Protect.
MB8 Panel
Figure 29. MB8 - Programmable Multibus 8 Control Panel
8053_21r0
PRESET
Remt 3
LEVEL
DigVideo
DESTID
LEVEL SRC
PREVSALVO NEXT
CECLEAR
STO
RCL
CHOP
STATUS 1
VTR 12
PROT
TAKE
STATUS 5
Black
PROT
TAKE
STATUS 2
PROT
TAKE
STATUS 6
PROT
TAKE
STATUS 3
PROT
TAKE
STATUS 7
PROT
TAKE
STATUS 4
PROT
TAKE
STATUS 8
PROT
TAKE
VTR 6
Netwk
Remt 7
DVE 2
DiskRcdr
CGEN 4
The SMS7000 MB8 (Multi-Bus 8) panel operates essentially the same as an Encore PMB panel, except it has two fewer programmable buttons on the left and the default button configuration is slightly different.
Default Button Configuration (MB8 Panel)The default button configuration for the MB8 panel is shown in Figure 30.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Encore — Control Panels Operation Manual 61
Section 4 — SMS7000 GSC Control Panels
Figure 30. MB8 Panel, Default Button Configuration and Keypad Sets
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
PDR9PDR9
I
VTR1VTR1
J
VTR2VTR2
K
VTR3VTR3
L
VTR4VTR4
M
VTR5VTR5
N
VTR6VTR6
O
VTR7VTR7
P
DESTDESTIDID
LEVELLEVEL SRCSRC
SALVOSALVO PREVPREV NEXTNEXT
SHIFTSHIFT
CECECLEARCLEAR
DESTDESTPAGEPAGE
LEVELLEVELPAGEPAGE
8053
_23r
0
Primary Keypad SetProgrammableFunction Buttons
Secondary Keypad Set
The Secondary Keypad set will only be available on the panel if the default configuration is changed to include a Shift button.
Note The PREV and NEXT buttons are not equipped with LEDs and so will not tally if programmed for a different function.
MB8 Panel OperationThe procedures for Takes, Protects, and Salvos are the same as those used on an Encore PMB panel. See PMB Panel on page 34 for operational infor-mation.
MB4 Panel
MB4 Panel DescriptionThe Multibus 4 Control Panel (MB4) controls four assigned output busses (Destinations). Status information and destination names are simultane-ously displayed, eliminating much mode switching. Destinations are typi-cally front-panel selectable so the MB4 can switch any Source to any Destination, depending on configuration.
A 16-button configurable keypad provides prefix/suffix access to fre-quently used sources and destinations. You can also scroll through com-plete name lists using the PREV and NEXT buttons. Destination Page Mode is also available for scrolling through Destination Pages applied to that panel.
62 Encore — Control Panels Operation Manual
MB4 Panel
Figure 31. MB4 - Programmable Mulitbus 4 Control Panel
Grass Valley
PRESET
Remt 3
LEVEL
DigVideo
DESTID
LEVEL SRC
PREVSALVO NEXT
CECLEAR DST PG
DST PG
CHOP
STATUS 1
VTR 12
PROT
TAKE
DEST 1
Black
HOLD
LOAD
STATUS 2
PROT
TAKE
DEST 2
HOLD
LOAD
STATUS 3
PROT
TAKE
DEST 3
HOLD
LOAD
STATUS 4
PROT
TAKE
DEST 4
HOLD
LOAD
VTR 6
Netwk
Remt 7
DVE 2
DiskRcdr
CGEN 4
Series 7000
8053_47r0
Default Button Configuration (MB4 Panel)The default button configuration for the MB4 panel is shown in Figure 30.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration.
Figure 32. MB4 Panel, Default Button Configuration and Keypad Sets
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
PDR9PDR9
I
VTR1VTR1
J
VTR2VTR2
K
VTR3VTR3
L
VTR4VTR4
M
VTR5VTR5
N
VTR6VTR6
O
VTR7VTR7
P
DESTDESTIDID
LEVELLEVEL SRCSRC
SALVOSALVO PREVPREV NEXTNEXT
SHIFTSHIFT
CECECLEARCLEAR
DESTDESTPAGEPAGE
LEVELLEVELPAGEPAGE
8053
_23r
0
Primary Keypad SetProgrammableFunction Buttons
Secondary Keypad Set
MB4 Panel OperationThe MB4 Control Panel operates similar to the MB8 Control Panel, except four Destinations are accessible at a time, status is available for both Desti-nations and Sources, and the addition of Hold and Load buttons for each Des-tination.
Hold Button
Press the Hold button so it is illuminated to keep that Destination assigned to that display area. Selecting new pages of Destinations will not change panel control of held destinations.
Encore — Control Panels Operation Manual 63
Section 4 — SMS7000 GSC Control Panels
Load Button
Pressing the Load button loads the currently preset Destination to that Control Panel display, provided a Hold is not active.
The Dest Page down button is not available. Destinations are chosen via paging using the upper Dest button, or via keypad, using the Prev/Next but-tons, or with assigned Destination buttons.
EDP Panel
Figure 33. EDP -Eight Destination Paging Control Panel
PRESET
LEVEL
Satt13
NTSC Vid
DESTID
LEVEL SRC
LEVELPAGE
DESTPAGE
STORE
SRCPAGE
SALVOPAGE
SHIFTA
CHOP
CECLEAR
SHIFTB
STATUS 1
DEST 1
CAMERA1
DVTR1
PROTHOLD
TAKELOAD
STATUS 2
DEST 2
CAMERA2
DVTR2
PROTHOLD
TAKELOAD
STATUS 3
DEST 3
CAMERA3
DVTR3
PROTHOLD
TAKELOAD
STATUS 4
DEST 4
CAMERA5
DVTR4
PROTHOLD
TAKELOAD
STATUS 5
DEST 5
CAMERA8
DVTR5
PROTHOLD
TAKELOAD
STATUS 6
DEST 6
DiskRcdr
DVTR6
PROTHOLD
TAKELOAD
STATUS 7
DEST 7
netwk144
DVTR7
PROTHOLD
TAKELOAD
STATUS 8
DEST 8
Remote21
DVTR8
PROTHOLD
TAKELOAD
PREV NEXT
8053_26r0
EDP Panel OperationThe SMS7000 EDP (Eight Destination Paging) panel operates essentially the same as an Encore PMB panel. The same default button configuration is used (Figure 34), and the procedures for Takes, Protects, and Salvos are the same, with one exception. The EDP panel uses a knob instead of Prev or Next buttons to scroll through the available items.
See PMB Panel on page 34 for operational information.
64 Encore — Control Panels Operation Manual
P48 Panel
Default Button Configuration (EDP Panel)
Figure 34.
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
PDR9PDR9
I
VTR1VTR1
J
VTR2VTR2
K
VTR3VTR3
L
VTR4VTR4
M
VTR5VTR5
N
VTR6VTR6
O
VTR7VTR7
P
DestDest
IDID
LevelLevel SrcSrc
DestDestPagePage
LevelLevelPagePage
SrcSrcPagePage
SalvoSalvoPagePage
ChopChop
CECE
ClearClear
ShiftShift
8053
_10r
0
Primary Keypad SetNotAssigned
ProgrammableFunction Buttons
Secondary Keypad Set
EDP Panel Button Defaults (Same as Encore PMB Panel)
P48 Panel
Figure 35. P48 - 48 Button-Per-Source Control Panel
PROT CHOPID
TALLYLEVEL
ALLLVLS
LVL1
LVL2
LVL3
LVL4
LVL6
LVL5
8053_33r0
P48 Panel OperationThe SMS7000 P48 (Programmable 48 button) panel operates the same as an Encore BPS panel. The same default button configuration is used (Figure 36), and the procedures for Takes, Protects, and Salvos are the same.
See BPS Panel on page 44 for operational information.
Default Button Configuration (P48 Panel)
Figure 36.
ProtProt
Lvl 1Lvl 1
ChopChop
Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 6Lvl 6Lvl 4Lvl 4
PrevPrev
All LvlsAll Lvls
ConfigConfig
TallyTally
IDID
Lvl 5Lvl 5
NextNext
Right 48 Buttons Default Configuration Top Row: Source 1 - 24
Bottom Row: Source 25 - 48
8053
_19r
0
P48 Panel Button Defaults (Same as Encore BPS Panel)
Encore — Control Panels Operation Manual 65
Section 4 — SMS7000 GSC Control Panels
PXY Panel SetThe PXY Panel Set consists of:
• PXS Master panel (typically configured with sources)
• PXD Expansion panel (typically configured with destinations)
• PXYE panel for Source, Salvo, or Destination Expansion
Figure 37. PXY Control Panel Group
8053_48r0
Bobs CamDESTINATION
Grass Valley
Series 7000
Bobs CamSOURCE
Grass ValleyNEXTSRC
NEXTDST
PREVSRC
PREVDST
SRCID
LEVELINV
PROT
CHOP
Series 7000
Bobs CamDESTINATION
Grass Valley
ID
Series 7000
PXS
PXYE
PXD
PXY Panel Set Features• The PXS can function alone or can work with one or more PXYE panels
and/or a single PXD panel. PXD and PXYE panels will not function without a PXS panel.
• All Control Panel buttons are programmable.
PXY Panel Set ConfigurationTo configure a PXY Panel set, the PXS panel is identified as a Master panel, and each PXD/PXYE panel is configured as a member of that Master panel’s group. See the separate Encore Installation & Service Manual for spe-cific panel group configuration instructions.
PXY Group Default Button Assignments
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration.
66 Encore — Control Panels Operation Manual
PXY Panel Set
PXS Default Button Assignments
Figure 38. PXS Panel, Default Button Configuration
SRCSRCIDID
PROTPROT
CHOPCHOP LEVELLEVELINVINV
PrevPrevSRCSRC
NextNextSRCSRC
PrevPrevDSTDST
NextNextDSTDST
8053
_52r
0
Right 32 Buttons Default ConfigurationTop Row: Source 1-16
Bottom Row: Source 17-32
With LEVEL selected:Levels 1-32
PXD Default Button Assignments
The Left eight buttons by default are configured as Level Select 1 - 8. The remaining buttons by default are configured as Destination 1-32.
PXYE Default Button Assignments
The isolated button on the left by default is configured as an ID button. The remaining buttons by default are configured as Destination 1-32.
PXS Source/Level Mode SelectionThe PXS panel typically has two modes of operation (Source mode and Level mode), selected with the SRC/ID and LVL/INV buttons.
• When SRC/ID is illuminated, the buttons on the right select Sources, Des-tinations, or Salvos, as configured.
• When LVL/INV is illuminated, the buttons on the right select Levels.
Taking a Source to a Destination (PXS Panel)1. Press the SRC/ID button, if necessary, to enter Source mode.
2. Press and hold the Prev DST or Next DST button until the name of the desired Destination is shown on the display.
3. Release the button to select that Destination for control.
4. Select the Source:
• Press a Source button on the right. That Source will immediately switch to the selected Destination.
- or -
a. Press and hold the Prev SRC or Next SRC button until the name of the desired Source appears on the display.
b. Release the button to Take that Source to the selected Destination.
Encore — Control Panels Operation Manual 67
Section 4 — SMS7000 GSC Control Panels
Taking a Source to a Destination (PXY Panel Group)Typically additional Destinations are configured on the PXD panel. Pressing a Destination button on the PXD panel in the group selects that Destination for control.
Typically additional Sources are configured on the PXYE panel. Pressing one if those buttons will Take that Source to the selected Destination.
Breakaway Take (PXS Panel)Breakaway Takes are performed the same as on a P32 Control Panel.
1. Press the LEVEL/INV button to enter Level mode. In this mode the buttons on the right no longer select Sources. The buttons now correspond to the Levels available and will be illuminated when they have been selected.
2. Press the selection buttons to toggle the desired Levels On or Off.
Note Pressing the LEVEL/INV button when it is illuminated will swap the Level selections (On Levels go Off, and Off Levels go On), provided the Level Inverse Lock flag is turned off in that panel’s configuration.
3. Press the SRC/ID button to enter Source mode.
4. Press the desired Source button, or scroll through the available Sources. The new Source is taken only to the selected Levels of that Destination.
Protect (PXS Panel)Toggle the PROT button to turn Protect On (illuminated) or Off for that Des-tination.
SCP - Simple Control Panel
SCP Panel DescriptionThe Simple Control Panel (SCP) is a hybrid mode panel that supports both keypad access of Sources and button-per-item access of Sources, Destina-tions, Salvos or Levels in any combination. The panel may control a single Destination, multiple Destinations, and from one to all system Levels (defined by the user during system configuration). The SCP also offers Protect and other functions.
68 Encore — Control Panels Operation Manual
SCP - Simple Control Panel
Figure 39. SCP - Simple Control Panel
8053_49r1
ON = PRESETOFF = STATUS
Bobs Cam
Grass Valley
ID
CLEARPROT
TAKE
Series 7000
Default Button Configuration (SCP Panel)The default button configuration for the SCP panel is shown in Figure 30.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration.
Figure 40. SCP Panel, Default Button Configuration and Keypad Sets
AUXAUX
9
BLACKBLACK
8
BARSBARSEDITEDIT
7
CARTCARTSTUSTU
0
testtestFSFS
VCRVCR
6
ENGENG
5
CAMCAMCGCG
4
NETNET
3
PDRPDR
2
REMREMVTRVTR
1
PDR1PDR1
A
PDR2PDR2
B
PDR3PDR3
C
PDR4PDR4
D
PDR5PDR5
E
PDR6PDR6
F
PDR7PDR7
G
PDR8PDR8
H
IDID
CLEARCLEARPROTPROT
TAKETAKE
SRCSRC1
DSTDST1
SRCSRC2
DSTDST2
SRCSRC3
DSTDST3
SRCSRC4
DSTDST4
8053
_53r
1
Keypad Set (or Programmable Buttons)
ProgrammableButtons
ProgrammableButtons
Status Display
SCP Panel OperationThe SCP operates similar to other SMS7000 model Control Panels, with the following differences:
• The Keypad Set consists of the Primary set (left 16 buttons) and half of the Secondary set (right 8 buttons). Shift functionality is not supported.
• Only Source selections can be preset using the keypad, for subsequent activation with the Take button.
• Destination and Salvo selections are always immediately executed.
• Shift Latching is not supported.
Encore — Control Panels Operation Manual 69
Section 5Kalypso Remote Aux Panels
IntroductionKalypso 32 button Remote Aux Panels can be used with an Encore version 1.7 or higher system. Older model Kalypso Aux Panels may need to have their software updated in order to work on an Encore system. See the Encore Release Notes for the latest installation and software update proce-dures. Once installed with the Encore software, Kalypso Remote Aux panels are configured the same as other Encore panels, using the Encore Panel Server application. See the Encore Configuration Manual for additional information.
Key Features• Web browser-based setup,
• 10Base-T Ethernet RJ-45 control interface, includes active and collision indication,
• Internal auto-ranging AC mains power supply,
• Back-lit buttons with display intensity adjustments,
• All buttons programmable, and
• Simple name-based identification.
Encore — Control Panels Operation Manual 71
Section 5 — Kalypso Remote Aux Panels
Remote Aux Panel Model TypesTwo different Remote Aux Panel models exist. Different names have been used for the documentation of these panels, depending on whether they are part of a Kalypso system or an Encore system.
• KAL-32AUX1, the original model name used for the 1RU Kalypso Remote Aux Panel, corresponds to the KSD (Kalypso Single Destina-tion) panel when used with Encore.
• KAL-32AUX2, the original model name used for the 2RU Kalypso Remote Aux Panel, corresponds to the KMD (Kalypso Multi Destina-tion) panel when used with Encore.
Note Because all the buttons on the KSD and KMD panels are programmable, it is possible to configure either panel for either single or multiple Destination control.
The Encore Panel Server OUI identifies Kalypso panels as KSD or KMD, and these terms are used in this section.
KMD PanelThe KMD panel has a group of 48 programmable buttons on the left (typi-cally used for selections), and a status display and ten programmable buttons on the right (typically used for functions). See Figure 41.
Figure 41. KMD Remote Aux Panel
KALYPSO REMOTE AUX PANEL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 M/E1
M/E2
M/E3
PgmPst
Hold
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Un-Shift
Shift KeySplit
NearSide
FarSide
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
AUX7
AUX8
AUX9
AUX10
AUX11
AUX12
AUX13
AUX14
AUX15
AUX16
Display Functionalityof BPS32
Function Buttons (10)Selection Buttons (48)
8053_27r0
The control panel button and display functionality of the KMD panel is modeled on the Encore BPS panel.
72 Encore — Control Panels Operation Manual
KMD Panel
KMD Panel IDThe KMD panel alphanumeric displays can report the following informa-tion for that panel.
• Panel IP Address
• Panel Name
• Controlled Destination Area
• Controlled Destination Name
• Name of the Panel Destination
• Name of the Current Tally Level
• Protect Override, if set
Holding down the Tally/ID button activates the panel ID mode.
You can interrupt the ID display sequence at any time by pressing any button to resume normal operation. It is not necessary to let the identifica-tion routine finish.
Default Button Configuration (KMD)The default button configuration for the KMD panel is shown in Figure 42.
Note Button assignments for a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Configuration Manual for more information.
Figure 42. KMD Default Button Configuration
ProtProt
Lvl 1Lvl 1
ChopChop
Lvl 2Lvl 2 Lvl 4Lvl 4
PrevPrev
All LvlsAll Lvls
ConfigConfig
TallyTally
IDID
Lvl 5Lvl 5
NextNext
Left Buttons Default Configuration Top Row: Source 1 - 16
Middle Row: Source 17 - 32Bottom Row: Source 33 - 48
8053
_30r
0
Not Assigned
KMD Panel OperationThe procedures for Takes, Protects, and Salvos are the same as those used on an Encore BPS panel. See BPS Panel on page 44 for operational informa-tion.
Encore — Control Panels Operation Manual 73
Section 5 — Kalypso Remote Aux Panels
KSD PanelThe KSD panel has 42 programmable buttons. The 32 on the left are typi-cally used for selections and the ten on the right are typically used for func-tions (Figure 43).
Figure 43. KSD Remote Aux Panel
KALYPSO REMOTE AUX PANEL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 M/E1
M/E2
M/E3
PgmPst
Hold
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Un-Shift
Shift KeySplit
NearSide
FarSide
8053_28r0
Function Buttons (10)Selection Buttons (32)
The control panel button functionality for the KSD panel is modelled on the Encore 48B panel except it has six fewer buttons.
Default Button Configuration (KSD)The default button configuration for the KSD panel is shown in Figure 44.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 44. KSD Default Button Configuration
SrcSrc
1717
SrcSrc
1818
SrcSrc
1919
SrcSrc
2020
SrcSrc
1 1
Lvl 1Lvl 1 Lvl 2Lvl 2 Lvl 3Lvl 3 TallyTallyLevelLevel
Left Buttons Default Configuration Top Row: Source 1 - 16
Bottom Row: Destination 1 - 16 80
53_3
1r0
Not Assigned
KSD Panel OperationThe KSD operating procedures are the same as those used on an Encore 48B panel. See 48B Panel on page 47 for operational information.
74 Encore — Control Panels Operation Manual
Section 6Acappella Control Panels
IntroductionAcappella remote panels can be used with an Encore systems. Older remote panels may need to have their software updated in order to work on an Encore system. See the Encore Release Notes for the latest installation and software update procedures. Once installed with the Encore software, Aca-ppella remote panels are handled by the Encore system the same as Encore 48B panels. See the Encore Configuration Manual for additional information.
Key Features• Web browser-based setup,
• 10Base-T Ethernet RJ-45 control interface, includes active and collision indication,
• Back-lit buttons with display intensity adjustments,
• All buttons programmable, and
• Simple name-based identification.
Acappella Remote Panel TypesSeveral different types of Acappella remote panels exist that are equipped with different sets of Source and Destination buttons. All Acappella remote panels have four Level buttons, a green Enable button, a red Protect button. Three representative panels are shown below. Figure 45 is a panel with 16
Encore — Control Panels Operation Manual 75
Section 6 — Acappella Control Panels
Sources and 16 Destinations. Note that under Encore control all buttons are configurable, and so may perform different functions.
Figure 45. 16x16 Remote Panel
8053_05r0
Figure 46 is a panel with 16 Sources and 8 Destinations.
Figure 46. 16x8 Remote
8053_34r0
Panel
Figure 47 is a panel with 8 Sources and 1 Destination.
Figure 47. 8x1 Single Destination Remote Panel
8053_34r0
Acappella remote panels are treated as ENC-48B panels by the Encore system. On-line Acappella remote panels are listed in the Panel Server GUI as ENC-48B panel types. The existing 48B panel configuration editor graphics and templates are used to program these panels, which display the maximum number of buttons.
Acappella Local PanelsAn Acappella matrix may be equipped with a local panel. Local panel buttons are incorporated into the front of the Acappella matrix frame.
Though the button layout and appearance of an Acappella local panel is similar to the Acappella remote panels described in this section, they are fundamentally different. Local panels are dedicated to only the Acappella matrix frame they are incorporated into and cannot be configured (except to support Level operation in conjunction with other Acappella matrix frames).
76 Encore — Control Panels Operation Manual
Default Button Configuration (Acappella Remote Panel)
Acappella local panel selection buttons are dedicated to specific Source and Destination connectors on that Acappella matrix, and cannot be used to switch crosspoints on other Encore system matrices.
If an Acappella matrix equipped with a local panel is part of an Encore system, the buttons on the local panel will be functional and can be used to change that matrix’s crosspoints. The status of these changes will also be reported on other Encore system panels configured to control the Sources and Destinations of that Acappella matrix.
Refer to the separate Acappella Instruction Manual for more information about Acappella matrix frames and local panels.
Default Button Configuration (Acappella Remote Panel)The default button configuration for all Acappella Remote Panels is the same as the Encore 48B panel, as is shown in Figure 48.
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 48. Acappella Remote Panel Default Button Configuration
8053_32r0
Source 1 to Source 16 Sources 17 through 24, Destination 17, Level 3 configured but no buttons exist
Tally Level
Dest 18
Dest 19
Level 1
Level 2
Level 4Destination 1 to Destination 16
Buttons not present on a given Acappella panel can be programmed but obviously will not be usable since the buttons don’t actually exist. Knowing which buttons are available on a particular Acappella remote panel type is required when these panels are programmed.
Note It may be useful to create control panel templates (from the basic 48B tem-plate) for each type of Acappella panel used. The appropriate functions can be assigned to buttons present on the panel, and buttons that do not exist could be configured as Not Assigned.
Encore — Control Panels Operation Manual 77
Section 6 — Acappella Control Panels
Acappella Remote Panel OperationThe procedures for Takes, Protects, and Salvos are the same as those used on an Encore 48B panel. See 48B Panel on page 47 for operational informa-tion.
78 Encore — Control Panels Operation Manual
Section 7JEP-100 Panel
IntroductionThe JEP-100 control panel is a locally-programmable, eight-character dis-play, full-matrix control, multiple Level break away panel. It was designed to operate with either Encore or Jupiter control systems.
The JEP-100 panel includes a fully-enclosed auto-sensing power supply. The panel has no power switch (the AC cord is disconnected to power down the panel).
JEP-100 Panel Features• 2 RU rack mount,
• Four alpha-numeric displays for status reporting,
• 96 programmable buttons, typically used for Source, Destination, and Level selection, and 12 additional programmable buttons, typically used for functions, and
• Joystick override.
SpecificationsPhysical Dimensions: 2 RU rack mount: 19 in. W x 3.5 in. H x approx. 4 in. D (483 mm W x 89 mm H x 102 mm D)
Weight: 2.25 lb. (1.02 kg.)
Operating voltage: 90 to 260 VAC
Operating current: 0.4 A @ 240 VAC or 0.65 A @ 120 VAC
Inrush current rating: 7.9 A
Power consumption: <100 W
Joystick override: Connector, 15-pin D, female.
Encore — Control Panels Operation Manual 79
Section 7 — JEP-100 Panel
Wiring between rear-panel connector and customer-supplied contact closure device: minimum 22 AWG (American Wire Gauge); maximum length, 30 feet (10 meters).
JEP-100 Panel DescriptionThe 96 buttons on the left of the panel can be programmed for any function. Typically the majority of these buttons are used for Source selection, but they may be assigned to control Destinations, Levels, or Salvos. The four displays report the names of the current Destination, Status (current Source routed to that Destination), Preset, Level, and menu information (Figure 49).
Figure 49. JEP-100 Control Panel
Destination
Status
Preset
Level
8053_44r0
Level Salvo Pst
Lock Dest Src
Down Clear Take
Up MenuAssignand
Select
1 2 3 4 5 6 7 8 9 10 11 12 13 14 21 22 23 24
45 46 47 48
15 16 17 18 19 20
71 7269 70
25 26 27 28 29 30 31 32 33 34 41 42 43 44
95 9693 94
35 36 37 38 39 40
91 9289 9085 86 87 8873 74 81 82 83 8475 76 77 78 79 80
65 66 67 6849 50 51 52 53 54 61 62 63 6455 56 57 58 19 60
Function Buttons (12)Programmable Buttons (96)
Destination, Status, Preset, and Level Displays
Note The JEP-100 panel can also be configured to display Level tally on the dis-plays. See the separate Encore Configuration Manual for specific information.
JEP-100 Default Button ConfigurationThe panel ships from the factory with numbered buttons installed on the left, and buttons on the right have legends showing default panel func-tions. All buttons are programmable.
80 Encore — Control Panels Operation Manual
JEP-100 Operation
Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.
Figure 50. JEP-100 Default Button Legends
46
COLORBAR
VTR001
VTR002
VIDEO
8053
_45r
0
24 Level Salvo Pst
Lock Dest Src
UpAssign
andSelect
Menu
Down Clear Take
23
4847
7271
9695
22
70
94
Destination
Status
Preset
Level
JEP-100 Operation
Selecting a Destination to ControlIf the desired Destination button is assigned, press the button of the Desti-nation you wish to control so it is illuminated.
If the Destination you wish to control is not assigned to a button, you can select it from a list of available Destinations.
1. Press Dest.
2. Use the Up and Down buttons to scroll to the desired Destination reported in the Preset window.
3. Press Take. The panel can now be used to control that Destination.
Encore — Control Panels Operation Manual 81
Section 7 — JEP-100 Panel
Taking a Source to a Destination
Using Assigned Buttons
1. Press the assigned button of the desired Destination. It’s name will be reported in the Destination window.
2. Press the assigned button of the desired Source. It will immediately be routed to that Destination and its name will appear in the Source window.
Using Scrolling Lists
1. Press the Dest button so it is illuminated.
2. Use the Up and Down buttons to scroll through the list of available Destinations, stopping when the desired one appears in the Destination window.
3. Press Take to select that Destination for control.
4. Press the Src button.
5. Use the Up and Down buttons to select the desired Source (its name will appear in the Source window).
6. Press Take. That Source will be routed to the selected Destination.
Breakaway Take (JEP-100 Panel)
Using Assigned Buttons
1. Select a Destination to control (see above).
2. Press the assigned buttons for the Levels you wish to change so only those buttons are illuminated.
3. Select a Source (see above). Only the selected Level’s Sources will switch.
Using Level Mode
1. Select a Destination to control (see above).
2. Press Level to enter Level mode.
3. Use the Up and Down buttons to scroll through the available Levels. When the Level name is shown in the Level window, press the Take button so that button illuminates. This selects that Level for control.
82 Encore — Control Panels Operation Manual
JEP-100 Operation
4. Confirm only the desired Levels have been selected, by scrolling through Scrolling through the list of Levels. The Take button will go on and off as each Level is selected.
5. Press Src to exit Level mode and enter Source Selection mode.
6. Select the desired Source, using an assigned button or by scrolling through the list of available Sources (see above). Only the selected Levels will change to the new Source.
Locking or Protecting a DestinationThe JEP-100 panel can be configured for Protect, Soft Lock, or Hard Lock capabilities (see the Encore Configuration Manual). One form of Destination lock or Protect can be enabled at a time. Protect is the default setting.
To Protect or lock a Destination, select the Destination for control and press press the Lock button so it is illuminated. Other panels (without override capabilities) will not be able to change that Destination.
To unlock or unprotect the Destination, press the Lock button again so it turns off.
SalvosButtons on the JEP-100 can be assigned to execute a Salvo.
Salvos that are not assigned can also be executed by selecting them from a list.
1. Press the Salvo button so it is illuminated.
2. Use the Up and Down buttons to scroll through the list of available Salvos and select the one desired.
3. Press Take to execute the Salvo.
Front Panel Button AssignmentButtons can be assigned using the JEP-100 front panel controls (provided the Panel Server Self Config Lock flag is turned off). These configuration changes are saved to that panel’s configuration stored on the Encore Panel Server.
1. Press Assign and Select to enter assignment mode.
2. Press the button type you wish to assign (Dest, Src, Level, or Salvo).
3. Use the Up and Down buttons to choose the desired item.
Encore — Control Panels Operation Manual 83
Section 7 — JEP-100 Panel
4. With the item displayed in the Preset window, press the physical button on the front panel to which you wish to assign that item.
5. Press Assign and Select to exit assign mode.
Front Panel Menu ProgrammingSome features can be configured on the JEP-100 from the front panel (pro-vided the Panel Server Self Config Lock flag is turned off):
• Destination Ganging - Allows simultaneous selection of multiple Des-tination for control.
• Alias Names - Displays Alias names in the windows.
• Brightness - Adjusts the intensity of the Display window text.
• ID - Reports the IP address and name of the panel.
• Sticky Levels - Retains the last selected Levels for breakaway Takes.
To access these features, press the Menu button, then use the Up and Down buttons to scroll through the list of options.
For features simply turned on or off, press the Take button to toggle the state.
Note The window reports the potential state, not the current state. For example, DstGng-N indicates Destination Ganging is ON. Pressing the Take button will change the indicator to DstGng-Y and turn OFF Destination Ganging.
84 Encore — Control Panels Operation Manual
Section 8Panel Operation Variations
IntroductionThe previous sections described basic operating procedures for the factory default configurations of various Encore system control panels. Control panels at most facilities are probably configured with different function-ality. This section lists some of the more important configuration variations available and briefly describes how they affect control panel operation.
For a complete listing of all the panel configuration parameters, refer to the separate Encore Configuration Manual.
Note If you have questions about the operation of a specific Encore control panel at your facility, contact the on-site engineer responsible for configuring and maintaining your Encore system.
Button Functions and SelectionsDifferent functions can be assigned to programmable panel buttons, including Source Selection, Destination Selection, Level Selection, Protect/Lock, Salvo, Previous, Next, and others.
If a control panel button is assigned a selection function, the specific item (a particular Source, Destination, Level, or Salvo) is configured to be selected by pressing that button.
Exclusion SetsSets of items (Area, Destination, Level, Salvo) can be programmed to be unavailable for control by a particular control panel. In larger facilities, lim-iting the control of some items (on-air Destinations, for example) to only some panels at selected locations can prevent important signals from being changed accidentally by some distant control panel.
Encore — Control Panels Operation Manual 85
Section 8 — Panel Operation Variations
Keypad SetsAlternative keypad sets can be created that change, for example, which pre-fixes and suffixes are entered for item names. Keypad sets can be shared with multiple panels. Typically the same keypads sets are used throughout a facility so the various panels operate the same, but this is not required.
Page SetsPanels with multiple displays support page sets, which group items together so they can be called up simultaneously. Page sets exist for Desti-nations and Salvos.
Dynamic Audio Attribute ControlAudio attributes on Concerto audio routers can now be dynamically con-trolled using Encore system Control Panels, or from an RCL Client (for example, an automation system). The audio attributes are: Stereo (Normal), Left Only, Right Only, Swap, Sum, Invert Left, Invert Right, and Mute. Five attributes are mutually exclusive and three are independent (Figure 51).
Figure 51. Dynamic Audio Attributes
CH1 CH1
CH2 CH2
Stereo (Default Normal)
Left Channel
Right Channel
CH1
CH2
Left Only
Right
Left CH1
CH2Left
CH1
CH2
Right Only
RightLeft CH1
CH2Right
CH1
CH2CH2
CH1
Swap
Right
RightLeft
Left
CH1
CH2
Sum
Right
Left CH1
CH2Left & Right
Left & Right
8153
_50r
0
Left Invert
CH1 CH1
CH2 CH2Right Channel
Right Invert
CHA CH1
CHB CH2
Left Channel
Mutally Exclusive Attributes (5)
Independent Attributes (3)
CH2
CH1
Mute
Right
Left
Any one of the five mutually exclusive attributes can be enabled at a time. One or more of the three independent attributes can be activated in combi-
86 Encore — Control Panels Operation Manual
Button Functions and Selections
nation with any other attributes. For example, you can Swap the channels and also invert the Left channel. Incoming (upstream) signals are inverted, so in this example the Left channel is inverted and that inverted signal is passed to the right channel (Figure 52).
Figure 52. Applying Multiple Dynamic Audio Attributes
CH1
CH2CH2
CH1
Swap
Right
RightLeft
Left
8153
_51r
0
Left Invert
CH1 CH1
CH2 CH2Right Channel
Mutally Exclusive Attributes (downstream)Independent Attribute (upstream)
Applying Mute silences both channels. If a Mute is applied in conjunction with any other attributes and the Mute is then released, the audio attributes previously set remain in force and are restored when Mute ends.
Dynamic audio attributes control are supported by the following matrices:
• Concerto (Analog and AES/EBU Digital Audio).
Note On Concerto Analog Audio matrices, matrix outputs must be wired as left-right channel pairs.
Multiple bus panels (PMB, EDP, MB8, MB4) do not support dynamic audio attribute control.
Dynamic Audio Configuration
Control Panels are configured for dynamic audio control by assigning these functions to buttons, using the standard Encore configuration procedures. Refer to the separate Encore Configuration Manual for details.
Dynamic Audio Operation
Once audio functions have been assigned to Control Panel buttons, they will behave as follows:
• Multiple destination Control Panels must be in Source mode to access the dynamic audio features.
• Pressing an unilluminated Audio Left Only, Audio Right Only, Audio Swap, or Audio Sum button lights that button, activates that audio attribute, and deactivates any of the other attributes in this group (they are mutually exclusive). Pressing one of these buttons when it is illuminated deacti-vates that attribute and restores the normal Stereo audio attribute.
Encore — Control Panels Operation Manual 87
Section 8 — Panel Operation Variations
• If an Audio Stereo button is configured on the Control Panel, it illumi-nates when no other mutually exclusive attribute is enabled. Pressing this button when it is not illuminated selects normal Stereo operation, disabling any other mutually exclusive audio attribute.
• The independent audio attributes buttons (Audio Invert Left, Audio Invert Right, Audio Mute) are enabled and disabled individually by pressing those buttons. These buttons illuminate when that attribute is active and go off when inactive.
• Salvos can be created to control dynamic audio attributes (on a salvo element by salvo element basis).
Attributes and FlagsSome control panel behavior not related to a particular button function or selection can be changed by setting control panel attributes and/or flags during panel configuration. Some of the control panel attributes and flags that significantly affect panel operation are described below.
General Settings
Auto Tally
Sets the Source Tally to the first active and enabled Level of the active Des-tination.
Note Turning Auto Tally ON disables Tally Level button functionality.
Auto Level Latching
When doing breakaway takes on panels without dedicated Level buttons, the selected breakaway Levels can be persistent (remain in force for subse-quent takes), or can be cleared automatically (revert to all Levels after per-forming a take).
• When the Auto Level Latching flag is on, the current enabled/disabled Levels state is applied to subsequent Takes for that active Destination. Selecting a different Destination cancels the breakaway.
• When the Auto Level Latching flag is off, all Levels of the current active Destination are enabled after a take or change of active Destination, regardless of the previous Level enable states(s).
88 Encore — Control Panels Operation Manual
Attributes and Flags
Default Tally Level
Specifies the Level that will Tally by default in panel displays if a Level has not been specifically selected for Tally on that panel.
Display Alias Names
Alternative, or Alias, names can be configured for Sources and Destina-tions. Setting this flag on will display alias names on control panels with displays.
Dst Change Lock
When on, Dst Change Lock disables the panel’s ability to change Destina-tions.
Level Change Lock
When on, Level Change Lock disables the panel’s ability to select indi-vidual Levels to perform a breakaway Take.
Protect and Lock SettingsBecause the Encore control system uses multiple points of control (various control panels, Encore OUI, automation interfaces) some flags affect how different control panels interact. Specifically, the Protect and Lock features determine how changing Sources to Destinations can be restricted. This is useful if, for example, a VTR operator needs to ensure that the incoming Source remains present for the duration of a recording, and is not switched to another Source by some other panel in the facility.
The Protect, Hard Lock, and Soft Lock flags are mutually exclusive. For example, setting a Hard Lock on a panel automatically clears a Protect or Soft Lock flag for that panel, if set.
Protect
The Protect flag allows a control panel to set Protects on Destinations. Once a Protect is set, other panels cannot change the Source to that Destination, but the panel that had set the Protect is able to change that Destination’s Source, with some exceptions. Other panels with Lock/Protect Override or Force Unlock/Protect flags set can change Sources on Protected Destina-tions.
Encore — Control Panels Operation Manual 89
Section 8 — Panel Operation Variations
Hard Lock
The Hard Lock flag acts like Protect, except even the panel that set the Lock also cannot change a locked Destination’s Source. That panel must first remove the lock before the Destination can be switched. Other panels with Lock/Protect Override or Force Unlock/Protect flags set can change Sources on Locked Destinations.
Soft Lock
The Soft Lock flag acts like Protect, except any other panel can also remove the Protect from a Destination.
Lock/Protect Override
Lock/Protect Override allows a panel to temporarily remove a Lock or Protect from a Destination, and change the Source to that Destination. The Lock or Protect remains in force after the change to the new Source.
Force Unlock/Protect
Force Unlock/Protect allows a panel to remove a Lock or Protect from a Destination.
Salvo Editor Lock/Protect
The separate Salvo Editor application supports creating Salvos with Lock-Protect/Unlock-Unprotect capabilities. Executing a Salvo with this setting ON can, for example, lock one or more Destinations. A Salvo can also created to unlock one or more Destinations, perform Takes, and then either leave the Destinations unlocked or restore the Lock. Some limitations exist, including the inability to override some Protects, depending on the device issuing the Salvo. See the separate Salvo Editor Instruction Manual for spe-cific information.
Control Panel GroupingSome control panels can be configured to act together as a single larger control panel. Typically a 48B panel is grouped with a panel that has control functions and displays, and the 48B panel is configured with additional Sources and/or Destinations. See the separate Encore Configuration Manual for specific information.
90 Encore — Control Panels Operation Manual
Attributes and Flags
Joystick OverrideSome control panels have GPI connectors that can be used for Joystick over-ride. Joystick override permits switching the displayed video to another Source, and then either returning to the previously selected Source or keeping the Override Source displayed. This feature is typically used for camera matching.
Joystick Override Configuration
Joystick override has two operating modes, latching and non-latching. The mode is selected by assigning either the Source or Source (non-latching) func-tion to the Joystick Source button.
The following control panels support Joystick override:
Table 1. Joystick Override Panel
Encore panels BPS, 48B
Kalypso panels KMD, KSD
SMS panels P48, P32
Note On grouped control panels only the master panel’s joystick override can be used.
See the separate Encore Configuration Manual and Encore Installation and Service Manual for information about setting up panels for Joystick over-ride.
Joystick Override Operation
Activating a non-latching Joystick override (typically done by pressing a button on a camera remote control unit) switches to that Source, and releasing the button restores the last Source. A latching override keeps the override Source displayed until another Source is selected.
If multiple non-latching overrides are active, releasing overrides steps back through previous overrides in the reverse order of their selection. The last selected override will be restored when another override is released. For example, suppose Source A is selected for a non-latching override and held, then Source B is selected for override and held, and then Source C is selected for override and held. In this case, releasing Source C override restores Source B override, and then releasing Source B override restores Source A override.
Encore — Control Panels Operation Manual 91
Index
Numerics48B panel 47
Auto Tally feature 48breakaway Take procedure 48default button assignments 47features 47general description 47Protect procedure 49Salvo procedure 49Take procedure 48Tally Level procedure 49
7500 control by Encore 14
AAcappella control by Encore 14Acappella local panel 76Acappella panel
buttons not present 77control panel templates 77default button assignments 77general description 75local 76operation 78software 75types 75
all level Take 21illustration 21
AllSvos 27Apex
control by Encore 14Area
definition 18Auto Level Latching flag 88Auto Tally feature 48Auto Tally flag 88
BBPS panel 44
breakaway Take procedure 45
default button assignments 44features 44general description 44Protect procedure 45Salvo procedure 46self configuration 46single destination default 45Take procedure 45
breakawaydefinition 18
breakaway Take 21illustration 21
breakaway Take procedureEncore 48B panel 48Encore BPS panel 45Encore PMB panel 36Encore XY panel 42JEP-100 panel 82SMS7000 P32 panel 60SMS7000 P3XS panel 68SMS7000 UCP panel 57
button assignmentJEP-100 panel 83
button selectionsavailable for panel buttons 85
Cchannel definition 18Chop
configuration 28definition 18general description 27limitations 29operation 28protect 29
Chop Lock 28Chop Switch Rate 28CLNT panel (Encore) 52
configuration 52Destination assignment 53Destination identification 53
Encore — Control Panels Operation Manual 93
Index
operation 52Source assignment 53Source identification 53Take procedure 53
CLNT panel (SMS7000) 59Concerto control by Encore 14configuration
control panel 25configuration PC
general description 17control panel
Acappella features 75Acappella types 24, 75communications interfaces 25configuration 25Encore 48B 47Encore 48B features 47Encore BPS features 44Encore Client 52Encore defaults 25Encore features 33Encore PMB 34Encore types 23Encore UCP 50Encore XY 40Encore XY features 40Encore XY general description 40general description 16grouping 90hardware types 23JEP-100 features 79Kalypso KMD 72Kalypso KSD 74Kalypso remote aux types 24, 72operation with non-default settings 85SMS7000 CLNT 59SMS7000 EDP 64SMS7000 MB4 62SMS7000 MB8 61SMS7000 P32 59SMS7000 P48 65SMS7000 PXY panel set 66SMS7000 SCP panel 68SMS7000 types 23SMS7000 UCP 56software 24software update 25
control panel buttonsavailable functions 85
available selections 85crosspoint
definition 18
Ddatabase
general description 17default button assignments
Acappella panel 77Encore 48B panel 47Encore BPS panel 44Encore PMB panel 35Encore UCP panel 50Encore XY panel 40JEP-100 panel 80Kalypso KMD panel 73Kalypso KSD panel 74SMS7000 EDP panel 65SMS7000 MB4 panel 63SMS7000 MB8 panel 61SMS7000 P32 panel 60SMS7000 P48 panel 65SMS7000 PXD panel 67SMS7000 PXS panel 67SMS7000 PXY panel set 66SMS7000 PXYE panel 67SMS7000 SCP panel 69SMS7000 UCP panel 56
DefaultTally Level flag 89Dest Ganging Option 1 30Dest Ganging Option 2 30Destination
definition 18general description 20
Destination assignmentEncore CLNT panel 53
Destination Ganging 30Breakaway Take 31configuration 30operation 30Protect 31
Destination identificationEncore CLNT panel 53
Destination name reportingEncore XY panel 41
Destination selectionJEP-100 panel 81
94 Encore — Control Panels Operation Manual
Index
Display Alias Names flag 89distributed control 17documentation online 4documentation set 11Dst Change Lock flag 89Dynamic Audio
configuration 87operation 87
Dynamic Audio Attribute Control 86Dynamic Page Set
configuration 39creation 39operation 39
EEDP panel 64
default button assignments 65general description 64operation 64
ENC UCP paneldefault button assignments 50operation 51
Encoredatabase 17distributed control 17documentation set 11general description 13system diagram 13
Encore 48B panelgeneral description 47
Encore BPS panel 44general description 44
Encore CLNT panel 52configuration 52Destination assignment 53Destination identification 53operation 52Source assignment procedure 53Source identification 53
Encore control panelPanel ID 33
Encore PMBfeatures 34general description 34
Encore System Controllerconnectors 15
general description 14multiple 15rear view 15
Encore system diagram 13Encore UCP panel 50
configuration as Server 52features 50general description 50
Encore XY panelstatus reporting 41
error messagespanel sign on 26
Ethernet 24exclusion set
definition 18types of 85
FFAQ database 4flag
Auto Level Latching 88Auto Tally 88Default Tally Level 89definition 18Display Alias Names 89Dst Change Lock 89Force Unlock/Protect 90Hard Lock 90Level Change Lock 89Lock/Protect Override 90Protect 89Soft Lock 90
Force Unlock/Protectflag 90
frequently asked questions 4Front
16x16 7616x8 768x1 76
functionsavailable for panel buttons 85
GGlobal Serial Channel (GSC) 24
general description 55
Encore — Control Panels Operation Manual 95
Index
Grass Valley web site 4grouping
control panel 90GSC (Global Serial Channel) 24GUI
Soft Panels 24
HHard Lock
flag 90hardware
controlled by Encore 14Hold button
MB4 panel 63Horizon control by Encore 14
JJEP-100 panel
breakaway Take procedure 82button assignment 83default button assignments 80Destination selection 81general description 80menu programming 84operation 81power supply 79Protect procedure 83Salvo procedure 83specifications 79Take procedure 82
Joystick override 91configuration 91latching 91non-latching 91operation 91
KKalypso KMD
panel operation 73Kalypso KSD
panel operation 74Kalypso remote aux panel
features 71general description 71
Panel ID 73software 71types 72
keypad setalternative 86
KMD control panel 72KMD panel
default button assignments 73operation 73
KSD control panel 74KSD panel
default button assignments 74operation 74
LLevel
definition 18general description 19
Level Change Lock flag 89licensing 24Load button
MB4 panel 64Lock
configuration 89relationship to Protect 89
Lock/Protectusing Salvos 90
Lock/Protect Overrideflag 90
Mmatrix
definition 18matrix crosspoints
general description 19MB4 panel 62
default button assignments 63general description 62Hold button 63Load button 64operation 63
MB8 panel 61default button assignments 61general description 61operation 62
96 Encore — Control Panels Operation Manual
Index
menu programmingJEP-100 panel 84
multi-level switchinggeneral description 21
NNetConfig
and SMS7000 panels 55
Oonline documentation 4
PP32 panel 59
breakaway Take procedure 60default button assignments 60features 59general description 59Protect procedure 61Take procedure 60
P48 panel 65default button assignments 65general description 65operation 65
page settypes of 86
Panel IDEncore control panel 33Kalypso remote aux panel 73
PMB panel 34breakaway Take procedure 36default button assignments 35features 34general description 34Protect procedure 38Salvo procedure 38Take procedure 35Tally Level procedure 37
presetdefinition 19
Protectand Quick Take mode 54configuration 89definition 19flag 89
general description 26relationship to Lock 89
Protect procedureEncore 48B panel 49Encore BPS panel 45Encore PMB panel 38Encore XY panel 43JEP-100 panel 83SMS7000 P32 panel 61SMS7000 PXS panel 68SMS7000 UCP panel 58
PXD paneldefault button assignments 67
PXS panelbreakaway Take procedure 68default button assignments 67Protect procedure 68Source/Level selection 67Take procedure 67
PXS panel groupTake procedure 68
PXY panel set 66configuration 66default button assignments 66features 66general description 66
PXYE paneldefault button assignments 67
QQuick Take mode 54
Rremote aux panel
features 71routing terminology 18
SSalvo
definition 19general description 27
Salvo Editor application 90Salvo Editor Lock/Protect 90Salvo procedure
Encore — Control Panels Operation Manual 97
Index
Encore 48B panel 49Encore BPS panel 46Encore PMB panel 38Encore XY panel 43JEP-100 panel 83SMS7000 UCP panel 58
SalvosAll Salvos 27
SCP panel 68default button assignments 69general description 68operation 69
self configurationEncore BPS panel 46
Sharergeneral description 17
Sharer PCgeneral descripion 18
Shiftconfiguration 29operation 29
Shift functionsControl Panel
Shift 29sign on error message 26SMS7000
Global Serial Channel 24SMS7000 control by Encore 14SMS7000 control panel
general description 55SMS7000 EDP
general description 64panel operation 64
SMS7000 MB4general description 62panel operation 63
SMS7000 MB8general description 61panel operation 62
SMS7000 P32features 59general description 59
SMS7000 P48general description 65panel operation 65
SMS7000 paneland NetConfig 55
software 55SMS7000 PXY panel set
configuration 66features 66general description 66
SMS7000 SCPpanel operation 69
SMS7000 SCP panelgeneral description 68
SMS7000 UCPfeatures 56general description 56
Soft Lockflag 90
Soft Panels 24general description 24GUI 24licensing 24
softwarecontrol panel 24control panel update 25
software download from web 4Source
definition 19general description 20
Source assignment procedureEncore CLNT panel 53
Source identificationEncore CLNT panel 53
Source name reportingEncore XY panel 41
status reportingEncore XY panel 41
System Controllergeneral description 14power supply module 15reset button 15
System Controller Frameslots 15
TTake
all level 21all level illustration 21breakaway 21breakaway iIlustration 21
98 Encore — Control Panels Operation Manual
Index
definition 19Take procedure
Encore 48B panel 48Encore BPS panel 45Encore CLNT panel 53Encore PMB panel 35Encore XY panel 41JEP-100 panel 82SMS7000 P32 panel 60SMS7000 PXS panel 67SMS7000 PXS panel group 68SMS7000 UCP panel 57
tallydefinition 19
Tally Level procedureEncore 48B panel 49Encore PMB panel 37
templatedefinition 19
terminology 18tie-line
definition 19general description 22
Trinixcontrol by Encore 14
UUCP panel (Encore) 50
configuration as Server 52default button assignments 50features 50general description 50operation 51
UCP panel (SM7000) 56breakaway Take procedure 57default button assignments 56features 56general description 56Protect procedure 58Salvo procedure 58Take procedure 57
Unlock/Unprotectusing Salvos 90
Vvirtual control panel 24
Wweb site documentation 4web site FAQ database 4web site Grass Valley 4web site software download 4
XXY panel 40
breakaway Take procedure 42default button assignments 40features 40general description 40Protect procedure 43Salvo procedure 43status reporting 41Take procedure 41
Encore — Control Panels Operation Manual 99