100
Encore CONTROL SYSTEM Control Panels Operation Manual Software Version 1.8.0 071805305 AUGUST 2010

Encore Control Panels Operation Manual, version 1.8

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

EncoreCONTROL SYSTEM

Control Panels Operation ManualSoftware Version 1.8.0

071805305AUGUST 2010

Affiliate with the N.V. KEMA in The Netherlands

CERTIFICATECertificate Number: 510040.001 The Quality System of: Thomson Inc, and its wor dwide Grass Valley division affiliates DBA GRASS VALLEY

Headquarters 400 Providence Mine Rd Nevada City, CA 95959 United States

15655 SW Greystone Ct. Beaverton, OR 97006 United States

10 Presidential Way Suite 300 Woburn, MA 01801 United States

Kapittelweg 10 4827 HG Breda The Nederlands

7140 Baymeadows Way Ste 101 Jacksonville, FL 32256 United States

2300 So. Decker Lake Blvd. Salt Lake City, UT 84119 United States

Rue du Clos Courtel CS 31719 35517 Cesson-Sevigné Cedex France

1 rue de l’Hautil Z.I. des Boutries BP 150 78702 Conflans-Sainte Honorine Cedex France

Technopole Brest-Iroise Site de la Pointe du Diable CS 73808 29238 Brest Cedex 3 France

40 Rue de Bray 2 Rue des Landelles 35510 Cesson Sevigné France

Spinnereistrasse 5 CH-5300 Turgi Switzerland

Brunnenweg 9 D-64331 Weiterstadt Germany

Carl-Benz-Strasse 6-8 67105 Schifferstadt Germany

Including its implementation, meets the requirements of the standard:

ISO 9001:2008 Scope:The design, manufacture and support of video and audio hardware and software products and related systems.

This Certificate is valid until: June 14, 2012 This Certificate is valid as of: June 14, 2009 Certified for the first time: June 14, 2000

H. Pierre Sallé President KEMA-Registered Quality

The method of operation for quality certification is defined in the KEMA General Terms And Conditions For Quality And Environmental Management Systems Certifications. Integral publication of this certificate is allowed.

KEMA-Registered Quality, Inc.4377 County Line Road Chalfont, PA 18914 Ph: (215)997-4519 Fax: (215)997-3809 CRT 001 073004

Accredited By:ANAB

EncoreCONTROL SYSTEM

Control Panels Operation ManualSoftware Version 1.8.0

071805305AUGUST 2010

4 Encore — Control Panels Operation Manual

Contacting Grass ValleyInternational

Support CentersFrance24 x 7 +800 8080 2020 or +33 1 48 25 20 20 United States/Canada

24 x 7 +1 800 547 8949 or +1 530 478 4148

Local Support Centers

(available during normal

business hours)

AsiaHong Kong, Taiwan, Korea, Macau: +852 2531 3058 Indian Subcontinent: +91 22 24933476Southeast Asia/Malaysia: +603 7805 3884 Southeast Asia/Singapore: +65 6379 1313China: +861 0660 159 450 Japan: +81 3 5484 6868

Australia and New Zealand: +61 1300 721 495 Central/South America: +55 11 5509 3443

Middle East: +971 4 299 64 40 Near East and Africa: +800 8080 2020 or +33 1 48 25 20 20

Europe

Belarus, Russia, Tadzikistan, Ukraine, Uzbekistan: +7 095 2580924 225 Switzerland: +41 1 487 80 02S. Europe/Italy-Roma: +39 06 87 20 35 28 -Milan: +39 02 48 41 46 58 S. Europe/Spain: +34 91 512 03 50Benelux/Belgium: +32 (0) 2 334 90 30 Benelux/Netherlands: +31 (0) 35 62 38 42 1 N. Europe: +45 45 96 88 70Germany, Austria, Eastern Europe: +49 6150 104 444 UK, Ireland, Israel: +44 118 923 0499

Copyright © Grass Valley, Inc. All rights reserved.This product may be covered by one or more U.S. and foreign patents.

Grass Valley Web Site The www.grassvalley.com web site offers the following:

Online User Documentation — Current versions of product catalogs, brochures, data sheets, ordering guides, planning guides, manuals, and release notes in .pdf format can be downloaded.

FAQ Database — Solutions to problems and troubleshooting efforts can be found by searching our Frequently Asked Questions (FAQ) database.

Software Downloads — Download software updates, drivers, and patches.

ContentsPreface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Documentation Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Section 1 — Encore System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Controlled Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Encore System Controller Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Encore System Control Fundamentals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Distributed Control System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Encore Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Sharer Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Configuration PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Sharer PC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Routing Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Matrix Crosspoints and Levels Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Sources and Destinations Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Multi-Level Switching Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

All Level Take. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Breakaway Take . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Tie-Line Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Section 2 — Control Panels Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Control Panel Hardware Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Encore Control Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23SMS 7000 Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Kalypso Remote Aux Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Acappella Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Soft Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Control Panel Communications Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Control Panel Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Control Panel Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Control Panel Defaults (Factory and Facility) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Factory Default Templates and Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Control Panel Sign On Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Control Panel Basic Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Protect and Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Salvos Excluded . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Chop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Chop Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Encore — Control Panels Operation Manual 5

Contents

Control Panel Chop Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Chop Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Chop Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Control Panel Shift Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Shift Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Shift Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Destination Ganging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Destination Ganging Configuration for v1.8.0 Software. . . . . . . . . . . . . . . . . 30Destination Ganging Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Breakaway Takes and Ganging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Protect and Ganging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Section 3 — Encore Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Panel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

PMB Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PMB Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PMB Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34PMB Panel Default Button Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Taking a Source to a Destination (PMB Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . 35Breakaway Take (PMB Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Level Tally (PMB Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Protect (PMB Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

To Protect a Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38To Unprotect a Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Salvo (PMB Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Dynamic Page Set Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Dynamic Page Set Panel Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Dynamic Page Set Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

XY Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40XY Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40XY Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40XY Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Status Display Reporting of Source and Destination . . . . . . . . . . . . . . . . . . . . . 41Taking a Source to a Destination (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Using Dedicated Destination and Source Buttons . . . . . . . . . . . . . . . . . . . . . . 41Switching Non-Dedicated Sources to Destinations . . . . . . . . . . . . . . . . . . . . . 41

Breakaway Take (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Protect (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Salvo (XY Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

BPS Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44BPS Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44BPS Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44BPS Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Default BPS Single Destination Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Taking a Source to a Destination (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Breakaway Take (BPS Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Protect (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Salvo (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Self Configuration (BPS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Source Self Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

6 Encore — Control Panels Operation Manual

Contents

Level Self Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Salvo Self Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

48B Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4748B Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4748B Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4748B Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Taking a Source to a Destination (48B Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Breakaway Take (48B Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Auto Tally and the Tally Level Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Tally Level Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Protect (48B Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Salvo (48B Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Universal Control Panel (ENC-UCP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UCP Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UCP Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UPC Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ENC-UCP Standalone Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Client Control Panel (ENC-CLNT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52ENC-CLNT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52ENC-CLNT Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

Changing Destinations on a Client Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Identifying Assigned Client Panel Destinations . . . . . . . . . . . . . . . . . . . . . . . . 53Assigning Sources to Client Panel Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Identifying Client Panel Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Taking a Source to a Destination (CLNT Panel) . . . . . . . . . . . . . . . . . . . . . . . . 53Quick Take Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Section 4 — SMS7000 GSC Control Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55UCP Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

UCP Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56UCP Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56UCP Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Taking a Source to a Destination (UCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Breakaway Take (UCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Protect (UCP Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Salvo (UCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

CLNT Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59P32 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

P32 Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59P32 Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59P32 Panel Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Taking a Source to a Destination (P32 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Breakaway Take (P32 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Protect (P32 Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

MB8 Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Default Button Configuration (MB8 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61MB8 Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

MB4 Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62MB4 Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62Default Button Configuration (MB4 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63MB4 Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Hold Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Encore — Control Panels Operation Manual 7

Contents

Load Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64EDP Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

EDP Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Default Button Configuration (EDP Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

P48 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65P48 Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Default Button Configuration (P48 Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

PXY Panel Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66PXY Panel Set Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66PXY Panel Set Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66PXY Group Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

PXS Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67PXD Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67PXYE Default Button Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

PXS Source/Level Mode Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Taking a Source to a Destination (PXS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . 67Taking a Source to a Destination (PXY Panel Group) . . . . . . . . . . . . . . . . . . . . . 68Breakaway Take (PXS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Protect (PXS Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

SCP - Simple Control Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68SCP Panel Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Default Button Configuration (SCP Panel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69SCP Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Section 5 — Kalypso Remote Aux Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71Remote Aux Panel Model Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

KMD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72KMD Panel ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Default Button Configuration (KMD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73KMD Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

KSD Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Default Button Configuration (KSD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74KSD Panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74

Section 6 — Acappella Control Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Acappella Remote Panel Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Acappella Local Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

Default Button Configuration (Acappella Remote Panel) . . . . . . . . . . . . . . . . . . . 77Acappella Remote Panel Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

Section 7 — JEP-100 Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

JEP-100 Panel Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79

JEP-100 Panel Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80JEP-100 Default Button Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

JEP-100 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

8 Encore — Control Panels Operation Manual

Contents

Selecting a Destination to Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Taking a Source to a Destination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Using Assigned Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Using Scrolling Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Breakaway Take (JEP-100 Panel). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Using Assigned Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Using Level Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

Locking or Protecting a Destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Salvos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Front Panel Button Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Front Panel Menu Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84

Section 8 — Panel Operation Variations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Button Functions and Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Exclusion Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85Keypad Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Page Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86Dynamic Audio Attribute Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

Dynamic Audio Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Dynamic Audio Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

Attributes and Flags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88General Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88

Auto Tally . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Auto Level Latching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Default Tally Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Display Alias Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Dst Change Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Level Change Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

Protect and Lock Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89Hard Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Soft Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Lock/Protect Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Force Unlock/Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Salvo Editor Lock/Protect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

Control Panel Grouping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90Joystick Override . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Joystick Override Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Joystick Override Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Encore — Control Panels Operation Manual 9

Contents

10 Encore — Control Panels Operation Manual

Preface

About This ManualThis Encore Control Panels Operation Manual is designed for operators of a Grass Valley Encore control system who are not involved in Encore system configuration or servicing.

Documentation SetThe basic Encore documentation set consists of:

• Installation and Service Manual,

• Configuration Manual,

• Control Panels Operation Manual, and

• Release Notes.

The Installation and Service Manual contains information about installing Encore system hardware, maintaining Encore system components, and configuring network communications used by the system.

The Configuration Manual contains information about configuring an Encore system to meet the needs of your facility. Background information about Encore system design is included, and a description of the Encore Operator User Interface (OUI); which is used to configure, test, and operate the system; is also provided.

The Control Panels Operation Manual provides operating information for the control panels used with the Encore Control System.

The Release Notes contain information about new features and system enhancements for a specific software version. Software installation proce-dures are also provided. Always review the Release Notes for your current system software before you begin working with your Encore system.

Encore — Control Panels Operation Manual 11

Preface

Additional DocumentationDocumentation for various Encore system options is also available:

• Encore Salvo Editor Instruction Manual,

• Soft Panels Instruction Manual, and

• Visual Status Display Instruction Manual.

The NetConfig utility program is used to configure your Encore network and install software:

• NetConfig Instruction Manual

Software engineering documentation, intended for third-party developers and in-house software engineers, is also available:

• Routing Products Protocols Manual.

12 Encore — Control Panels Operation Manual

Section 1Encore System Overview

Note This same Overview section is included in several Encore manuals. If you are familiar with this material you can skip to the next section.

IntroductionThe Encore system is an open, scalable platform for full router and facility control. Featuring tight integration with Grass Valley router matrices, third-party routers, automation systems, and other equipment, the Encore system can consolidate media assets under a single, unified control system.

Figure 1. Encore Facility Control System

Encore SystemController(s)

EncoreSerial Controller

VTRs

Profile VDRs

Acts AsGatewayBetweenEN 1 and

EN 2

Encore OperatorWorkstation(s)

Notification viaPager, E-mail

or Phone

Trinix Digital VideoRouting Matrix

Apex Digital AudioRouting Matrix

AcappellaRemote Panels

AcappellaRouting Matrices

Encore EthernetControl Panels

PMB

48BEDP

P32

UCP

MB8

P48

XY

BPS

Series 7000Routing Matrices

SMS 7000Control System

ConcertoMulti-Format

Routing Matrix

7500 WB Digital Video Routing Matrix

7500 NB Digital AudioRouting Matrix

NetCentralSNMP Manager

Distributed Applications:

Serial Interface Options:

• System Manager• Router Control• Panel Servers• Tie-Line Manager

Encore EngineeringWorkstation

Windows GUI Applications:

Windows GUI Applications:

• Configuration• Local Router Panel• Local Machine Control Panel• Router Status

• Local Router Panel• Local Machine Control Panel

• Automation• ES Switch/Jupiter• 3rd Party Matrix/Tally• Horizon Matrix

RS-4

22

Cros

spoi

nt B

us

8053

_00r

0

Encore Controllerwith GSC Option

Encore Controller withRS-422 Serial Option

75 Ω

Coa

x Series 7000Control Panels

EN 1 Ethernet (Facility LAN) EN 2 Ethernet (Panel/Matrix LAN)

RS-4

22

Encore — Control Panels Operation Manual 13

Section 1 — Encore System Overview

The Encore system modular design lets broadcasters and other high-quality content creators select just the level of control they need. At its most basic, the Encore system can configure and control the crosspoints of a single routing matrix, but it can be expanded to control multiple matrices.

Controlled HardwareEncore can control a wide range of Grass Valley routers including Trinix, Apex, Concerto, Acappella, 7500 WB, and 7500 NB using Ethernet. Legacy 7000 Series and Horizon routers can be serially controlled. In addition, Encore can control the popular Grass Valley Venus routers with a serial interface to a VM-3000 protocol translator. A wide range of third party routers can also be controlled through a number of supported serial inter-faces. Users can also add tally and machine control via Ethernet or serial interfaces.

Encore System Controller FrameThe two rack-unit Encore System Controller Frame supports up to two System Controller Board (SCB) modules and two power supply modules for redundancy. A standard Encore System Controller Frame is equipped with one SCB and one power supply. All modules are front removable and hot pluggable. Cooling is built into the frame so no external cooling units are required.

Figure 2. Encore System Controller Frame

8053_09r0

14 Encore — Control Panels Operation Manual

Introduction

The System Controller Frame has two slots for SCBs and two slots for Power Supply modules, located behind the front cover/air filter. Status indicator LEDs and a reset button are located on each SCB (Figure 3).

Figure 3. System Controller and Power Supply Modules

Power Supply Modules

Reset Buttons

System Controller Modules

8053

_36r

0

Slot 1Slot 2

Slot 1Slot 2

Cabling and power connectors are located on the rear of the System Con-troller Frame (Figure 4).

Figure 4. System Controller Frame Rear View

8053_37_r0

J31USB J19J20J21J29J30

GPIIN

GPIOUT J5J6J7

GSC 4 GSC 3 GSC 2 GSC 1 REF OUT SYNC 2 SYNC 1

CONSOLECONSOLE

J1J2J3J4

J16

J35

J51

COM1

COM2

J52J53

EN1

EN2

J54

J36J37J38J39SIO 45678 3 2 1

J40J41J42J43J44J45J46J47J48J49J50

J17J18 J15J26J27J28J32J33

GPIIN

GPIOUT J12J13J14

GSC 4 GSC 3 GSC 2 GSC 1 REF OUT SYNC 2 SYNC 1

J8J9J10J11

J23J24J25 J22J34USBPS1

PS2

COL LNKLNK COL COL LNKLNK COL

J55

+

J56

COM1

COM2

J57J58

EN1

EN2

J59

SIO 45678 3 2 1

30-60V130W; 3.7A

Serial In/OutConnectors (8)

Com 1Console Port

EN1Ethernet Port

EN2Ethernet Port

SCB Slot 2 Connectors

DCPower

GPI In/OutConnectors (2)

GSC BNCs (8) Sync BNCs (4)

Com 2Port

SCB Slot 1 Connectors

GPI In/OutConnectors (2)

GSC BNCs (8) Sync BNCs (4)

Serial In/OutConnectors (8)

Com 1Console Port

EN1Ethernet Port

EN2Ethernet PortAC

Power

Com 2Port

Multiple Encore System Controller Frames can be used to support large systems and to increase throughput by dividing tasks among the control-lers. SCBs in the same frame can be configured to control different hard-ware or to operate redundantly. An SCB in one frame can even operate redundantly with an SCB in a different frame.

Encore — Control Panels Operation Manual 15

Section 1 — Encore System Overview

Control PanelsA wide variety of hardware control panels are available that can work across the room or across the country via IP LAN/WAN connections. Many Grass Valley legacy hardware control panels can also be used with optional serial interfaces. Optional PC control panel software is also available that emulates many of these hardware panels.

The control panel operator views and selects Sources and Destinations by name and does not need to be concerned with the actual physical cabling or numbers of inputs and outputs.

Two representative Encore control panels are illustrated below.

Figure 5. Encore Paging Multi Bus (PMB) Control Panel

Status 1

Des t inat ion 1

P reset

Leve l

Status 2

Des t inat ion 2

Status 3

Des t inat ion 3

Status 4

Des t inat ion 4

Status 5

Des t inat ion 5

Status 6

Des t inat ion 6

Status 7

Des t inat ion 7

Status 8

Des t inat ion 8

DestDest

IDID

LevelLevel SrcSrc

DestDestPagePage

LevelLevelPagePage

SrcSrcPagePage

SalvoSalvoPagePage

ChopChop

CECE

ClearClear

ShiftShiftA

PrevPrev NextNext

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

8053_03r0

Figure 6. Encore Button Per Source (BPS) Control Panel

Des t inat ion Status

ProtProt

Lvl 1Lvl 1

ChopChop

Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 5Lvl 5

NextNext

Lvl 6Lvl 6Lvl 4Lvl 4

PrevPrev

All LvlsAll Lvls

ConfigConfig

TallyTally

IDID

8053_04r0

An Acappella control panel and an SMS7000 control panel, both originally developed for other routing systems but able to be configured to work with Encore, are illustrated below.

Figure 7. Acappella 16x16 Remote Panel

8053_05r0

Figure 8. SMS7000 P48 Control Panel

Grass ValleyGrass Valley

PROT CHOPID

TALLYLEVEL

ALLLVLS

LVL1

LVL2

LVL3

LVL4

LVL6

LVL5

8053_08r0

16 Encore — Control Panels Operation Manual

Introduction

Encore System Control Fundamentals

Distributed Control System

The Encore system uses a distributed control networked architecture. Various Encore software components are installed on different hardware locations to perform different tasks. This design provides extraordinary system power and flexibility. Configuration files are downloaded over the network to target devices, permitting rapid configuration changes while the Encore system remains operational. User-specific system-wide access privileges can also be established to restrict system control as appropriate.

Encore Database

Information vital to Encore system operation resides in a collection of data files, collectively called the Encore database. These files model the routing matrix hardware being controlled, name input Sources and output Destina-tions, determine matrix Levels, and specify the operational capabilities of the control panels. The Encore database is created when the system is com-missioned and is typically maintained by facility engineering staff. The Encore database resides on the same PC as the Sharer.

Sharer Application

The Sharer application automatically downloads configuration informa-tion to Encore system components when they are power up or reboot. The Sharer application runs on a PC, and must be running when the Encore system is configured. The Sharer does not need to be running to sustain control panel operation. However, we recommend the Sharer application run at all times, as this makes it easier to resume configuration procedures.

CAUTION An Encore system can have only one Sharer application running on the network at any time. This is important to remember during software installa-tion, or if a notebook PC with the Sharer is moved to different locations.

Configuration PC

An Encore system is configured using a standard PC installed with the appropriate Encore software. Once configured, Encore control panels will be able to switch crosspoints on routing matrices even if the configuration PC is turned off or disconnected from the network. Typically the configu-ration PC also has the Encore Sharer application installed, but this applica-tion can reside on any PC on the network.

Encore — Control Panels Operation Manual 17

Section 1 — Encore System Overview

Sharer PC

The Sharer PC is the PC on which the Sharer is installed. Typically the con-figuration PC and Sharer PC are the same, but separate PCs can be used.

Routing Basics

TerminologyArea - An Area is a defined group of Sources and Destinations. Takes are restricted to connecting Sources and Destinations within the same Area (unless Tie-Lines are used). Defining multiple Areas makes it possible to assign the same easily identifiable Source and Destination names (like VTR_1, VTR_2) for use by different devices at different locations in the facility.

Breakaway - A Take operation that switches a Source on at least one Level that is different from the Sources selected on the other Levels.

Channel - The communication path used to control the crosspoint group by the Router Control Engine over a selected protocol such as Serial or Ethernet paths.

Chop - A variation of a Take command that alternately connects each of two different Sources to a single Destination (flip-flopping) at a designated switching rate (the chop rate).

Note Encore 1.7.4 and earlier software does not support the Chop feature.

Crosspoint - An electronic switch that allows a signal to pass from an input to an output when the switch is closed.

Destination - The location to which Source signals are routed. A Destination may include one or more outputs across multiple Levels.

Exclusion Set - User-determined set of items excluded from control by a par-ticular control panel. Exclusion sets can be created for Areas, Destinations, Levels, or Salvos. An exclusion set may be shared by more than one panel.

Flag - A parameter that can be set in a control panel template to control how a panel operates.

Level - A grouping of signals of a particular type, such as digital video, audio right, audio left, Red, Green, or Blue, etc. This grouping becomes an independently controllable stratum of signals within a routing system.

Matrix - A configuration of potentially intersecting inputs and outputs. In routing switchers, a matrix is signal switching hardware configured such that any input may be switched to any output.

18 Encore — Control Panels Operation Manual

Routing Basics

Preset - Selecting an item (for example a Source or Destination) in prepara-tion for an action.

Protect - A control function that prevents control panels or devices from changing the current Source selection for the specified Destination.

Salvo - A named, system-wide preset which, when executed, can change crosspoints on multiple Destinations at the same time.

Source - An input signal or collection of input signals generally associated with a particular device (like a VTR or DDR). A Source may contain signals from multiple Levels.

Take - The direct, immediate switching of a different Source to a Destination. The Take occurs during the vertical interval for a clean transition.

Template - A set of parameters that can be applied to a control panel’s con-figuration. The same template can be applied to multiple panels.

Tally - A status acknowledgment returned to a control panel or terminal that an operation has been executed. Typically this will light up a button, but a Tally may report text (for example a Source name).

Tie-Line - A system tie-line is a physical connection used to give a Destina-tion connected to the output of one matrix access to Sources connected to the input of another matrix. A signal which passes through two or more matrices; more specifically the path (consisting of one or more Tie Wires) which links a Destination of one matrix to a Source of another matrix. A local tie-line is a special type that has Sources and Destinations in the same matrix, usually sending the signal out of the matrix for external processing.

Matrix Crosspoints and Levels DescriptionEach router matrix can be broken down into a number of switching matrices. A single switching matrix controls the switching (or routing) of a particular type of electrical signal (e.g. digital video, analog video, audio, data, etc.). These different signal formats are referred to as Levels. When a connection is made, a path is formed between a unique Source (logical grouping of physical inputs) and a unique Destination (logical grouping of physical outputs). The physical connection is accomplished using cros-spoint circuitry. Figure 9 illustrates how a single switching matrix operates.

Encore — Control Panels Operation Manual 19

Section 1 — Encore System Overview

Figure 9. A Single Switching Matrix

Outputs

8053

_15_

r0

Inputs0 1 2 3 4 5 6 7 8 9

0123456789

Any of the 10 inputs (numbered 0 to 9) can be routed to any of the 10 outputs (numbered 0 to 9). One input can also be routed to more than one output. All the possible routes are represented by the intersections of the horizontal and vertical lines in the illustration. The points where the lines meet (crosspoints) can be thought of as switches that allow the inputs to be connected to the outputs. In this example, three crosspoints are on (as indi-cated by the X symbols), and the following routes are made:

• Input 2 is routed to Output 1 and Output 4.

• Input 7 is routed to Output 6.

Sources and Destinations DescriptionSources consist of input signals to the router, and Destinations are output signals from the router. An individual Source or Destination may contain more than one signal. For example, a Source may consist of a video and a key signal; be separate Red, Green, and Blue video signals; or have a video signal and several associated audio signals. Each signal type is considered a Level. In general, a Source and Destination need to be configured with same number and type of Levels in order for Takes connecting them to be successful.

20 Encore — Control Panels Operation Manual

Routing Basics

Multi-Level Switching Description

All Level Take

An all Level Take switches the same input number on all Levels, to the con-trolled Destination, as shown in Figure 10.

Figure 10. Traditional All Level Take

Video Source A (VSA)

Audio Left Source A (ALSA)

Audio Right Source A (ARSA)

DVTR 1Source Devices Routing Matrix

Destination Device

Video Source B (VSB)

Audio Left Source B (ALSB)

Audio Right Source B (ARSB)

DVTR 2

Video Destination

Audio Left Destination

Audio Right Destination

DVTR 3

Audio Level

Video Level

VSA

ALSA

ARSA

VSB

ALSB

ARSB

VSA

ALSA

ARSA

8053

_06_

r0

Breakaway Take

A Breakaway Take is performed by selecting a Source different from the others (on at least one Level) to the controlled Destination. Breakaways allow a Destination to use different Sources (Figure 11).

Figure 11. Breakaway Take

Video Source A (VSA)

Audio Left Source A (ALSA)

Audio Right Source A (ARSA)

DVTR 1

Video Source B (VSB)

Audio Left Source B (ALSB)

Audio Right Source B (ARSB)

DVTR 2

Video Destination

Audio Left Destination

Audio Right Destination

DVTR 3

Audio Level

Video Level

VSA

ALSA

ARSA

VSB

ALSB

ARSB

VSA

ALSB

ARSB

8053

_07_

r0

Source Devices Routing Matrix

Destination Device

Encore — Control Panels Operation Manual 21

Section 1 — Encore System Overview

Tie-Line DescriptionTie-lines can be used to link different matrices, allowing Sources in one matrix to be routed to Destinations in another matrix. Each tie-line has a Source Name and a Destination Name that defines the signal path. A tie-line Source is actually a Destination of the first matrix, and the tie-line Des-tination is a Source of the second matrix. Routes that employ more than one tie-line are called multi-hop tie-lines (Figure 12).

Figure 12. Tie-Lines

Matrix 1Sources

8053

_42_

r0

Routing Matrix 1 Matrix 1Destinations

Tie-Line

Tie-Line

Tie-Line Source Name

Tie-LineSourceName

Tie-Line Source NameTie-Line Destination Name

Tie-Line Destination Name

Tie-LineDestinationName

Matrix 2Sources

(One Hop)

(Second Hop)(First Hop)Tie-Line

Routing Matrix 2 Matrix 2Destinations

Matrix 3Sources

Routing Matrix 3 Matrix 3Destinations

Once configured on an Encore system, actual tie-line operation is trans-parent to the operator. The Tie-Line Manager application automatically creates and releases tie-line paths as needed.

22 Encore — Control Panels Operation Manual

Section 2Control Panels Overview

Control Panel Hardware TypesAn Encore system supports many types of hardware control panels, several of which were originally developed for other routing systems.

Encore Control Panels• Paging Multi-Bus (PMB)

• Forty-Eight Button (48B)

• Button-Per-Source (BPS)

• XY Panel (XY)

• Universal Control Panel (ENC-UCP)

• Client Control Panel (ENC-CLNT)

SMS 7000 Control Panels• Eight Destination Paging (EDP)

• 48 Button-Per-Source (P48)

• Universal (UCP)

• Programmable Multibus 8 (MB8)

• Programmable Multibus 4 (MB4)

• 32 Button-Per-Source (P32)

• PXY Panel Group (PXS, PXD, PXYE)

• Simple Control Panel (SCP)

Note Legacy MCO and COS panels and a custom RIB interface are also supported by Encore 1.7.3 and newer software. These are not widely used and are not described in this manual.

Encore — Control Panels Operation Manual 23

Section 2 — Control Panels Overview

Kalypso Remote Aux Panels• KAL-32AUX1

• KAL-32AUX2

Acappella Control Panels• Several different hardware models, ranging from 16x16 to 8x1

Soft PanelsBesides hardware control panels, software emulations of control panels are also available. Soft Panels are virtual versions of physical control panels that can run on PCs connected to an Encore network. Soft Panels feature a Graphical User Interface (GUI) that represents the various specific panel types supported. Once configured, each Soft Panel type operates the same as the corresponding hardware panel. Soft Panels are sold separately from the Encore system and are individually licensed.

See the separate Encore Soft Panels Instruction Manual for more information.

Control Panel Communications InterfacesEncore, Acappella, and Kalypso panels use Ethernet and require the use of Ethernet switches and Cat 5 Ethernet cabling.

SMS 7000 control panels use Global Serial Channel (GSC) communications, and require installation of a GSC mezzanine in the Encore System Con-troller and 75 Ohm coaxial cabling for operation.

Refer to the separate Encore Installation and Service Manual for more infor-mation.

Control Panel SoftwareEncore control panels ship from the factory with Encore software installed and will be ready for network and operational configuration. You may need to update Encore control panel software to the latest version, how-ever, particularly if you use previously purchased Encore panels with your Encore system.

24 Encore — Control Panels Operation Manual

Control Panel Configuration

Control panels developed for other systems will need to have their soft-ware updated for use with Encore. These panels can then be configured using the Encore system OUI.

This manual, intended for operators, assumes the control panels being used have already been updated with the correct software and configured for operation. Software installation and upgrade procedures for specific Encore software releases are covered in the separate Encore Release Notes. Control panel configuration procedures are covered in the separate Encore Configuration Manual.

Control Panel ConfigurationThe configuration of a particular control panel defines how that panel behaves. For example, the panel configuration determines which Destina-tions and Levels a panel can control, which buttons perform which func-tions, and how the control panel accomplishes other operations.

Template files are available that can be used as a starting point for panel configuration. When a new control panel is added to an Encore system, it automatically receives configuration information from a default template for that type of panel. This configuration can then be saved with the name of that panel, and be modified to change the behavior of that panel. That configuration is then used by that control panel, unless it is modified or a different template file is loaded to that panel.

Some operations described in this manual may be limited by system or panel configuration constraints. Refer to the Encore Configuration Manual for system and control panel configuration instructions.

Control Panel Defaults (Factory and Facility)Encore systems ship with factory default control panel templates. This allows a control panel to be taken out of its box and used immediately.

Encore systems support different control panel default templates. The factory defaults cannot be edited by the user. Custom templates can be created for each type of panel, and you can specify these defaults are to be used when a new panel of that type is added to the Encore system.

Note Different Encore software versions may have factory panel default files with different settings, resulting in different behavior for new panels added to a system, depending on the version of Encore software being run.

Encore — Control Panels Operation Manual 25

Section 2 — Control Panels Overview

Factory Default Templates and AreasControl panel factory defaults are based upon the default Area (Area 1) configuration. Areas create hierarchies within the Encore Control System which makes it easier to group Sources and Destinations in a large system. The default Area is where control panels find their defaults. If Area 1 has been configured with Sources, Destinations, and Levels, then the control panels will operate using the Area 1 defaults. Once an Area is defined, an Area prefix is automatically assigned to each Source and Destination in the Area by the router engine. The Area prefix is part of the system name and can be displayed on certain panels. Typically, in most installations, a single Area is used.

If multiple Areas are used at a facility, some or all of the control panels may need to be re-configured before they can be used.

Control Panel Sign On Error MessagesAn Encore system Control Panel displays an error message if it fails to sign on to the Panel Server. These messages include:

• DUP_NAME - Duplicate name

• MAX_PNLS - Panel exceeds the maximum number

• UNKN_PNL - Unknown panel type

• SERV_ERR - Internal Server Error. The Panel Server failed to register the panel.

• OUI_EDIT - Same panel name is being edited in OUI

• PNL_NAME – Panel name length more than 8 characters

• NO_LICNS – None or insufficient licenses (Soft Panel only)

Control Panel Basic Functions

Protect and LockIn general, the Protect function (enabled/disabled during panel configura-tion) locks the Source selections for all the Levels of a Destination. When a Destination has been Protected by a panel, other panels in the facility will not be able to change that Destination’s Source selections (unless that other panel has been configured with a Protect Override). The panel which initi-ated the Protect can still be used to change Sources for a Destination that panel has protected, and that panel can also remove the protection from that Destination.

26 Encore — Control Panels Operation Manual

Control Panel Basic Functions

There are actually several different Protect and related Lock parameters that provide different capabilities that interact with each other. These include Hard Lock, Soft Lock, and Lock/Protect Override. The actual behavior of a specific panel depends on the setting of these parameters.

Refer to Section 8-Panel Operation Variations and the separate Encore Config-uration Manual for more information.

Salvos ExcludedSalvos can switch multiple Sources to multiple Destinations with a single button press. Default Encore panel configurations exclude all Salvos, to prevent accidentally changing multiple crosspoints on an existing Encore system when a new panel is installed.

The default setting for Encore control system panels excludes all Salvos. To use Salvos with a control panel, its configuration must be edited and re-loaded to that panel.

An AllSvos Salvo Set is available with v1.8.0 and newer Encore software that can make all Salvos available on a panel (hardware, Soft Panels, or RCL Cli-ents). With this setting selected, newly created Salvos are automatically added to this list, so a panel with this setting will always be able to execute any system Salvo.

Refer to the separate Encore Configuration Manual for specific instructions.

CAUTION Be sure you understand what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destinations with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.

ChopThe Chop feature allows two sources to be switched rapidly on a Destina-tion. The switching occurs between the current Source taken to that Desti-nation and a new Source selected for the Chop. This feature is useful for signal timing, camera matching etc.

The following matrices support the Encore Chop feature:

• Concerto (video only)

• Trinix (video only)

• Acappella (video only)

• 7500WB

Encore — Control Panels Operation Manual 27

Section 2 — Control Panels Overview

Chop is performed on a Level by Level basis, which means Breakaway Chop is available. Encore Level formats that support Chop for the above matrices are:

• Any (*)

• Composite (V)

• Component (C)

• Dig Video (D)

• SDi+Audio (E)

• Key (K)

Note Audio, Timecode, Data, and Other Levels do not support Chop.

All Encore system Control Panels support Chop except the CLNT/SVR and MCO/COS custom panels.

Chop Configuration

Encore system Control Panels need to be configured with Chop function-ality, using the Encore Control Panel Server OUI. Chop is activated on a Control Panel by making sure the Chop Lock flag is OFF (indicator is gray) in the Configuration Attributes and Flags menu and saving that configura-tion.

The rate at which the Sources will be switched during Chop is specified using the Encore Router Controller Application, by going to the Options menu and clicking on Chop Switch Rate. The valid range is 15 - 100 frames.

Refer to the separate Encore Configuration Manual for specific information.

Control Panel Chop Operation

1. Select the Destination for control that you wish to Chop. It cannot be Protected.

2. Press the Chop button so it illuminates.

3. Select an alternate Source from the same Area. That new Source and the original Source will be switched to that Destination at the specified switch rate, and CHOPPING will be reported on panels equipped with displays. On panels with dedicated Source buttons the button of the original Source will be high tally and the button of the chopping Source will blink (if the Flashing LED Indication flag is applied to the panel).

Note When Chop is active, selecting a different Source for that Destination on that Control Panel will Chop between that new Source and the original Source.

28 Encore — Control Panels Operation Manual

Control Panel Basic Functions

4. Press the illuminated Chop button to stop the Chop function. The original Source will be restored.

Take commands issued to a currently chopping Destination from any Panel stops the Chop function, and Takes that new Source to that Destination.

Chop Protect

A chopping Destination can be protected. Once protected, a chopping Des-tination must be unprotected before the Chop can be stopped.

Chop Limitations

The Chop feature Control Panel button tally correctly identifies the sources only on the local panel that initiated the Chop. The button for the original source will be high tally and the alternate chopping Source will blink (if the Flashing LED Indication flag is on that panel). A different Control Panel assigned to that Destination will report Chopping on its menu (if present) but will not blink the alternate Source’s button.

Changes made to Chop activity are not propagated across the Encore system. An unprotected chopping Destination can be altered to Chop to another source by a different Control Panel. If this occurs, the buttons on the panel that initiated the changed chopping Source will tally correctly, but the original panel will continue to blink the previous chopping Source (it will not change its tally status to reflect the new Source).

Control Panel Shift FunctionsShifted button functionality is available on all Encore system Control Panels except ENC-CLNT, SMS-CLNT, SMS-COS, SMS-MCO, and SMS-SVR. This feature allows a doubling of the number of functions available on a panel. For example, a BPS32 panel can be configured to access 64 Sources.

Shift Configuration

You will need to define the shifted button functions and add a Shift button to the panel’s configuration, using the Control Panel Server. Once config-ured, the Shift button goes high tally when the panel is in the shifted oper-ating mode.

Shift Operation

1. Press the Shift button on the panel so it is illuminated.

2. Press any button configured with a Shifted function. That function will immediately be performed.

Encore — Control Panels Operation Manual 29

Section 2 — Control Panels Overview

Destination Ganging

Background

Destination Ganging has been available for Encore 48B and JEP-100 Control Panels, as briefly described below.

• On 48B panels, holding down one Destination button and pressing and releasing others would Gang those Destinations, allowing Takes of the same Source to multiple Destinations with one button press. Selecting a Destination without holding down a button cancelled the Gang. This method can be considered Dest Ganging Option 1.

• On the JEP-100 Control panel, a front panel configuration setting could be used to activate Destination Ganging, at which time Destination buttons could be toggled on and off to add or remove them from a Gang. This can be considered Dest Ganging Option 2.

Destination Ganging Configuration for v1.8.0 Software

With Encore v1.8.0 and newer software, Destination Ganging functionality is added to the Encore BPS, SMS P32, P48, & PXS, and KMD & KSD Control Panels. Ganging Option 1 and Option 2 are both available on all these Control Panels, and on the Encore 48B panel. Option 2 Ganging becomes available on the Soft Panel equivalents for these panels, and continues to be available on the JEP-100 Control Panel.

If a hardware panel is configured with a Shift button, Ganging Option 1 is automatically disabled and only Ganging Option 2 will be supported. Because both the Shift and Ganging Option 1 features employ a button hold-down technique, they cannot both be active at the same time

Control panels that support both Destination Ganging options are config-ured with the Dest Ganging Option 2 flag, using the Encore Control Panel Server OUI. Refer to the separate Encore Configuration Manual for specific information.

Destination Ganging Operation

Ganging Option 1

1. Press and hold down a Destination button on the Control Panel.

2. Press and release other Destination buttons. They will illuminate, indicating they are included in the Gang. These buttons will blink if the Ganged Destinations currently route different Sources, and will be high tally if they all currently route the same Source.

3. Choose a Source. That source will be Taken to all the Destinations in the Gang.

30 Encore — Control Panels Operation Manual

Control Panel Basic Functions

Ganging Option 2

1. Toggle on the Destination buttons you wish to have in the Gang. Touching a Ganged Destination button removes it from the Gang.

2. Choose a Source. That source will be Taken to all the Destinations in the Gang.

Breakaway Takes and Ganging

Destination Ganging operations are applied to the currently enabled Levels, so breakaway Ganged Takes are supported.

Protect and Ganging• If a Protect or Lock is active on the primary ganged Destination,

attempts to create a Destination Gang will be ignored.

• If a Protect or Lock is active on an additional Destination, that destina-tion will not be added to the Gang.

• Protect or Lock conditions can also be applied (or removed) to all the destinations in a Gang.

Encore — Control Panels Operation Manual 31

Section 2 — Control Panels Overview

32 Encore — Control Panels Operation Manual

Section 3Encore Control Panels

Introduction

Key Features• Web browser-based setup,

• 10/100Base-T Ethernet RJ-45 control interface, includes active and col-lision indication,

• Internal auto-ranging AC mains power supply,

• Back-lit buttons for use in low-light conditions with display intensity adjustments,

• Simple name-based identification, and.

• Chop (all Encore system Control Panels support Chop except the CLNT/SVR and MCO/COS custom panels).

Panel IDEncore panels equipped with alphanumeric displays can report the fol-lowing information for that panel (as appropriate).

• Panel IP Address

• Panel Name

• Controlled Destination Area Name

• Controlled Destination Name

• Name of the Current Active Level

• Protect Override, if set

• Tieline Name, if used

With default panel configurations, pressing the Dest/ID button on PMB and XY panels when these buttons are already illuminated, or holding down

Encore — Control Panels Operation Manual 33

Section 3 — Encore Control Panels

the TallyLvl/ID button on BPS panels, will activate the panel ID mode. On PMB and XY panels, pressing the Src button when it is illuminated reports additional information in the various displays on the panel.

You can interrupt the ID display sequence at any time by pressing a dif-ferent mode button. It is not necessary to let the identification routine finish. Pressing a button during the ID display does not execute that button’s function, but instead cancels the ID reporting.

PMB Panel

PMB Panel Features• 2RU rack mount,

• Multi bus display of both Source and Destination,

• Individual Protects per Destination,

• Paging mode offers the ability to scroll through pages of Sources, Des-tinations, Levels, and Salvos,

• Previous / Next scrolling within prefix group,

• 30 user-defined programmable buttons,

• 16 button user-defined prefix /suffix keypad, with shift capability to support up to 32 prefixes and suffixes,

• Dynamic page set creation, and

• Panel grouping, with the PMB acting as master panel with Encore 48B and/or Kalypso KSD expansion panels.

PMB Panel DescriptionThe PMB (Paging Multi-Bus) panel has a group of programmable buttons and a display for Preset and Level on the left, a programmable keypad in the center, and eight Status and Destination displays on the right (Figure 13).

34 Encore — Control Panels Operation Manual

PMB Panel

Figure 13. PMB Panel

Status 1

Des t inat ion 1

P reset

Leve l

Status 2

Des t inat ion 2

Status 3

Des t inat ion 3

Status 4

Des t inat ion 4

Status 5

Des t inat ion 5

Status 6

Des t inat ion 6

Status 7

Des t inat ion 7

Status 8

Des t inat ion 8

DestDest

IDID

LevelLevel SrcSrc

DestDestPagePage

LevelLevelPagePage

SrcSrcPagePage

SalvoSalvoPagePage

ChopChop

CECE

ClearClear

ShiftShiftA

PrevPrev NextNext

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

ProtProt

HoldHold

TakeTake

LoadLoad

Keypad Buttons (16)

Programmable Buttons (30)

Prev Next Prot/Hold (8) Take/Load (8)

Status and Destination Displays (8)Preset and Level Display

8053_02r1

PMB Panel Default Button AssignmentsThe default button configuration for the PMB panel is shown in Figure 14.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 14. PMB Panel, Default Button Configuration and Keypad Sets

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

PDR9PDR9

I

VTR1VTR1

J

VTR2VTR2

K

VTR3VTR3

L

VTR4VTR4

M

VTR5VTR5

N

VTR6VTR6

O

VTR7VTR7

P

DestDest

IDID

LevelLevel SrcSrc

DestDestPagePage

LevelLevelPagePage

SrcSrcPagePage

SalvoSalvoPagePage

ChopChop

CECE

ClearClear

ShiftShift

8053

_10r

0

Primary Keypad SetNotAssigned

ProgrammableFunction Buttons

Secondary Keypad Set

The Keypad is initially assigned the Default Keypad Sets, with the Primary keypad set active. To access the Secondary keypad set, press the Shift func-tion button.

Default panel configurations have the Chop feature inactive.

Taking a Source to a Destination (PMB Panel)The Take operation connects an incoming Source to an outgoing Destina-tion. The PMB panel is able to control multiple Destinations (statuses for

Encore — Control Panels Operation Manual 35

Section 3 — Encore Control Panels

eight Destinations are displayed simultaneously). You will choose which Destination you wish to change, preset the desired Source, and then perform the Take.

1. If the desired Destination is not already shown in one of the eight Status displays on the right, load that Destination to a status display.

a. Press the Dest/ID button to enter Destination mode.

b. Assign the desired Destination to the Preset display. You can either:

• Use the Prev or Next buttons (holding down the button to scroll), or,

• Enter the prefix and suffix with the keypad (if the panel config-uration supports this operation). With a prefix selected, you can use the Prev and Next buttons to scroll through the available items with that prefix, or you can use the keypad to enter suffix num-bers. The CE/Clear button is used to incrementally clear keypad entries.

c. Load that preset Destination to one of the Status displays on the right by pressing the Take/Load button for that display. These buttons are illuminated (and active) only when Preset has a valid item.

Note A panel’s configuration may exclude control of some Destinations or Levels. Excluded items will not be selectable in the Preset display.

2. Select the desired Source in the Preset display.

a. Press the Src button to enter Source mode.

b. Assign the desired Source to the Preset display (use the same procedure as Step b of Taking a Source to a Destination (PMB Panel) on page 35).

3. Press the Take/Load button on the Status display on the right for that Destination to take that preset Source. The name of the new Source will be displayed in that Destination’s status display.

Note If Destination and/or Source pages have been configured, the Dest Page and Src Page buttons can be used to browse successive groups of eight items.

Breakaway Take (PMB Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will preset the Destination, examine the status for that Destination’s Levels, select the Level(s) to be changed, select the Source, and then Take that Source to only those Destination’s Levels.

36 Encore — Control Panels Operation Manual

PMB Panel

Note Destinations with active breakaways display an asterisk (*) in their Destina-tion Status displays.

1. Assign the Destination on which you wish to perform a breakaway Take to the Preset display.

a. Press the Dest/ID button to enter Destination mode.

b. Assign the desired Destination in the Preset display (use the same procedure as Step b on page 36).

2. Press the Level Page button to enter Level mode. In this mode the Status displays on the right show the status of only the preset Destination (not eight different Destinations). The current Sources of each Level for that Destination are shown.

3. Illuminate the Take/Load buttons for only the Destination Levels you wish to change by toggling these buttons on or off. At least one Level must be selected.

4. Press the Src button to enter Source mode.

5. Assign the desired Source to the Preset display (use the same procedure as Step b on page 36).

6. Press the Take/Load button on the Status display on the right for the desired Destination. The name of the new Source will be displayed in that Destination’s status display and an asterisk will indicate it has a breakaway.

Note After setting up Levels for a breakaway, subsequent Take operations will change only those Levels for any currently selected Destination, not just the preset Destination.

Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations, until the Level selections are changed or a different Destination is selected.

Level Tally (PMB Panel)When a PMB panel displays the status of eight Destinations, each Destina-tion reports only one Source. When Destinations have multiple Levels and breakaways are active, you may wish to choose which Level’s Source will be reported for each Destination.

1. Press the Level button to go to Level status selection mode.

2. Use the Prev and Next buttons to cycle through the available Levels and leave the name of the desired Level displayed.

Note If ALLLVL is selected the panel will report the Default Tally Level configured for that panel.

Encore — Control Panels Operation Manual 37

Section 3 — Encore Control Panels

3. Press the Src button to return to Source mode. Now Sources for the Level you selected will be reported on the Destination Status displays.

Protect (PMB Panel)

Note With default panel configurations, only the control panel that set the Protect can unprotect that Destination. When a Protect has been set, the Prot button on the panel that set the Protect will blink, and the Prot buttons on other panels accessing that Destination will be illuminated without blinking.

Note Pressing and holding a steadily illuminated Prot button on a panel with a text display will report the name of the panel that set the Protect.

To Protect a Destination

1. If the desired Destination is not already shown in one of the eight Status displays on the right, load that Destination to a status display (use the same procedure as Step 1 on page 36).

2. Press the Prot button located to the right of the Status display for the Destination you wish to Protect. The Prot button will blink on that panel. The Prot buttons will also illuminate steadily on all other Encore panels in your system with that Destination selected, indicating it is protected.

To Unprotect a Destination

1. If the desired Destination is not already shown in one of the eight Status displays on the right, load that Destination to a status display (use the same procedure as Step 1 on page 36).

2. Toggle the blinking Prot button so it is no longer illuminated.

Note PMB panels do not report Protects for Destinations not currently assigned to the Status displays. Care should be taken to relinquish all unneeded Protects before changing Destinations on these panels. You should also remember to free up all Destinations no longer requiring protection before you leave the vicinity of the PMB panel.

Salvo (PMB Panel)When a PMB panel has been configured with Salvo capabilities, you will be able to select a Salvo and execute it.

38 Encore — Control Panels Operation Manual

PMB Panel

CAUTION Be sure you understand exactly what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destina-tions with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.

1. Press the Salvo Pg button to enter Salvo mode. The first page of available Salvos will be displayed in the Status displays on the right.

2. If multiple pages of Salvos have been configured, use the Prev and Next buttons to move through the available pages of Salvos.

3. When the desired Salvo is displayed, press the Take/Load button on that Status display to execute the Salvo.

4. Press the Src button to return to Source mode. If Destinations involved in that Salvo are displayed, their Status displays will report their new Sources.

Dynamic Page Set CreationEncore PMB Control Panels (and also SMS EDP, MB8, and MB4 Control Panels) support Dynamic Destination Page Creation. This feature allows the user to create a new Destination Page Set using the Control Panel front panel buttons.

Dynamic Page Set Panel Configuration

The panel needs to have a Store button configured as one of its program-mable buttons. The Encore Panel Server OUI is used for panel configura-tion. Refer to the separate Encore Configuration Manual for specific instructions.

Dynamic Page Set Operation

1. Place the Control Panel in Destination Mode (by pressing the Dest button), preset a Destination you wish to use in the new Page Set (by scrolling, and assign it to a Status and Destination display on the right. The Store button will illuminate.

2. Repeat Step 1 above for all the Destinations you wish to change in that Page Set.

3. Press the Store button. A new Destination Page named DynPG(n) will be created and a new Page Set named PgSet(n) is also created that includes that new Destination Page. The new Destination Page and Page Set are also available for use on any other Control Panel supporting this feature, by configuring that panel with the Panel Server OUI.

Encore — Control Panels Operation Manual 39

Section 3 — Encore Control Panels

XY Panel

XY Panel Features• 1RU rack mount,

• Status, Preset, and Level display with three 8-character readouts,

• 16 button programmable keypad (2 rows of eight), and

• 18 programmable buttons, 10 on the left and 8 on the right.

XY Panel DescriptionThe XY panel’s name represents the fact that all inputs (X) mapped to the panel are available to all outputs (Y) mapped to that panel. The XY panel has a display for Status, Preset and Level, a programmable keypad, and two groups of programmable buttons on the far left and right (Figure 15).

Figure 15. XY Control Panel

Status

Preset

Leve l

DestDest

IDID

ChopChop

SrcSrc

CECE

ClearClear

SalvoSalvo

PrevPrev

LevelLevel

NextNext

ProtProt

TakeTake

8053_12r1

Programmable Keypad Buttons (16)

Programmable Buttons (10) Programmable Buttons (8)Status, Preset, and Level Display

XY Panel Default Button AssignmentsThe default function and selection button configuration for the XY panel is shown in Figure 16.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 16. XY Default Button Configuration

8053

_13r

0

DestDest

IDID

ChopChop

SrcSrc

CECE

ClearClear

SalvoSalvo

PrevPrev

LevelLevel

NextNext

ProtProt

TakeTake Destination 1 toDestination 4

Source 1 toSource 4

Default Function Buttons(10 Buttons on Left)

Default Selection Buttons(8 Buttons on Right)

40 Encore — Control Panels Operation Manual

XY Panel

The default Keypad set for the XY panel is shown in Figure 17.

Figure 17.

AUXAUX

9

BARSBARS STUSTU

0

BLACKBLACK

8

CAMCAM

CARTCART

CGCG

4

FSFS

NETNET

3

PDRPDR

2

REMREM ENGENG

5

VCRVCR

6

EDITEDIT

7

testtest

VTRVTR

1

8053

_14r

0

XY Default Keypad Configuration

Status Display Reporting of Source and DestinationThe state of one Destination at a time can be reported in the XY panel status display. The display can also report Source and Destination names for the dedicated XY panel buttons.

• When a dedicated Destination selection button is pressed and released so it is illuminated, the name of the current Source for that Destination is shown in the status display.

• Holding down a dedicated Destination button displays the name of that Destination. This lets you confirm the panel’s Destination button configuration before use.

• When a non-dedicated Destination has been loaded to the Preset dis-play, pressing the Src button to go to Source mode will make the Status display report the name of the current Source for that Destination.

Taking a Source to a Destination (XY Panel)The Take operation connects an incoming Source to an outgoing Destina-tion. An XY panel can switch any Source to any Destination (provided the panel’s configuration has not excluded them from control). XY panels can also be configured with dedicated Source and Destination buttons.

Using Dedicated Destination and Source Buttons

If the XY panel has buttons dedicated for the Destination and Source you wish to connect, simply touch the Destination button so it is illuminated, then touch the desired Source button. The name of the new Source will be reported in the status display.

Switching Non-Dedicated Sources to Destinations

Destinations not mapped to XY panel buttons will need to be loaded to the preset display. You then select a Source and perform the Take.

Encore — Control Panels Operation Manual 41

Section 3 — Encore Control Panels

Note A panel’s configuration may exclude control of some Destinations and Levels. Excluded items will not be selectable in the Preset display.

1. Press the Dest/ID button to enter Destination mode.

2. Assign the desired item to the Preset display. You can either:

• Use the Prev or Next buttons (holding down the button to scroll), or,

• Enter the prefix and suffix with the keypad (if the panel configura-tion supports this operation). With a prefix selected, you can use the Prev and Next buttons to scroll through the available items with that prefix, or you can use the keypad to enter suffix numbers. The CE/Clear button is used to incrementally clear keypad entries.

3. Load that Destination to preset by pressing the Take button. The name of that Destination will be reported in the display.

4. Press the Src button to enter Source mode.

5. Select the desired Source on the preset display (use the same procedure as Step 2 above).

6. With the name of the desired Source displayed, press the Take button. The connection will be made and the name of the new Source will be reported in the status display.

Note If the desired Source is mapped to an XY panel button, pressing that button in Source mode with the Destination preset will simultaneously select that Source and perform the Take.

Breakaway Take (XY Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will preset the Destination, select the Level(s) to be changed, select the Source, and then Take that Source to only those Destination’s Levels.

Note A Destination with an active breakaway displays an asterisk (*) in the Status display.

1. Assign the Destination on which you wish to perform a breakaway Take to the Preset display (see Step 1 through Step 3 of Switching Non-Dedicated Sources to Destinations on page 42).

2. Press the Level button to enter Level mode. In this mode you use the Prev and Next buttons to cycle through the available Levels for that Destination.

3. Illuminate the Take button for only the Destination Levels you wish to change by toggling the button on or off as you cycle through the Levels with the Prev and Next buttons. At least one Level must be selected.

42 Encore — Control Panels Operation Manual

XY Panel

4. Press the Src button to enter Source mode.

5. Select the Source for the breakaway Take, using the same procedure as Step 2 of Switching Non-Dedicated Sources to Destinations on page 41).

6. Press the Take button. The new Source will be connected to only the selected Levels and an asterisk will appear in the Status display to indicate it has a breakaway.

Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations, until the Level selections are changed or a different Destination is selected.

Protect (XY Panel)

Note With default panel configurations, only the control panel that set the Protect can unprotect that Destination. When a Protect has been set, the Prot button on the panel that set the Protect will blink, and the Prot buttons on other panels accessing that Destination will be illuminated without blinking.

Note Pressing and holding a steadily illuminated Prot button on a panel with a text display will report the name of the panel that set the Protect.

With the desired Destination selected, either by pressing its dedicated Des-tination button or assigning it to the Preset display, toggle the Prot button to turn Protect On (illuminated) or Off for that Destination.

Note XY panels do not report Protects for Destinations not currently assigned to the Status display. Relinquish all unneeded Protects before changing Desti-nations on these panels. Also remember to free up all Destinations no longer requiring protection before you leave the vicinity of the XY panel.

Salvo (XY Panel)When an XY panel has been configured with Salvo capabilities you will be able to select a Salvo and execute it.

CAUTION Be sure you understand exactly what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destina-tions with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.

1. Press the Salvo button to enter Salvo mode.

2. Use the Prev and Next buttons to move through the available pages of Salvos.

3. When the desired Salvo is displayed, press the Take button on that Status display to execute the Salvo.

Encore — Control Panels Operation Manual 43

Section 3 — Encore Control Panels

BPS Panel

BPS Panel Features• 1RU rack mount,

• Eight character Destination Status display,

• 42 user-defined programmable buttons, and

• Panel self configuration for alternative Source selection.

BPS Panel DescriptionThe BPS panel has a Destination Status Display on the left and two groups of programmable buttons (Figure 18).

Figure 18. BPS Control Panel

Des t inat ion Status

ProtProt

Lvl 1Lvl 1

ChopChop

Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 6Lvl 6Lvl 4Lvl 4

PrevPrev

All LvlsAll Lvls

ConfigConfig

TallyTally

IDID

Lvl 5Lvl 5

NextNext

Selection Buttons (32)Function Buttons (10)All Buttons Programmable

(typical configuration shown)

Destination Status Display

8053_16r0

BPS Panel Default Button AssignmentsThe default function and selection button configuration for the BPS panel is shown in Figure 19.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 19. BPS Default Button Configuration

ProtProt

Lvl 1Lvl 1

ChopChop

Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 6Lvl 6Lvl 4Lvl 4

PrevPrev

All LvlsAll Lvls

ConfigConfig

TallyTally

IDID

Lvl 5Lvl 5

NextNext

Right 32 Buttons Default Configuration Top Row: Source 1 - 16

Bottom Row: Source 17 - 32

8053

_17r

0

44 Encore — Control Panels Operation Manual

BPS Panel

Default BPS Single Destination OperationThe default configuration for a BPS panel limits the scope of its control to a single Destination. For example, this panel can be dedicated to control inputs to a particular VTR. Operating procedures for the default single Des-tination configuration are be described in this section.

BPS panels are not limited to single Destination control, however. All of the buttons on the BPS panel can actually be programmed for any function or Source selection (except these panels do not support keypads). This makes it possible to configure a BPS panel with capabilities similar to an XY panel, except it will lack a keypad and have limited status reporting.

Taking a Source to a Destination (BPS Panel)On a default single Destination BPS, Sources are selected by pressing the desired Source selection button on the right. The Source is immediately taken to that Destination and the name of that Source is reported in the Des-tination Status display.

Breakaway Take (BPS Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will select the Level(s) to be changed, then Take that Source to only those Destination’s Levels.

Note A Destination with an active breakaways displays an asterisk (*) in the Status display.

1. Toggle the Lvl buttons to illuminate the Levels of that Destination you wish to change.

2. Press the desired Source selection button. That Source will be taken to only the selected Levels, and an asterisk will appear in the Status display to indicate it has a breakaway.

Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations until the Level selections are changed or a different Destination is selected.

Protect (BPS Panel)

Note With default panel configurations only the control panel that set the Protect can unprotect that Destination. When a Protect has been set the Prot button on the panel that set the Protect will blink, and the Prot buttons on other panels accessing that Destination will be illuminated without blinking.

Encore — Control Panels Operation Manual 45

Section 3 — Encore Control Panels

Note Pressing and holding a steadily illuminated Prot button on a panel with a text display will report the name of the panel that set the Protect.

Toggle the Prot button to turn Protect On (illuminated) or Off for that Des-tination.

Salvo (BPS Panel)The default configuration for a BPS panel does not include any Salvo but-tons. If your panel has been configured for this feature a Salvo is fired simply by pressing the Salvo button configured for this purpose.

Self Configuration (BPS Panel)More than 32 Sources can be accessed by the BPS panel using the Self Con-figuration feature. This features allows BPS panel buttons to be remapped using the panel itself. BPS panel Level and Salvo buttons can also be self configured.

The normal reconfiguration process (using the Encore Panel Server appli-cation running on a PC to edit that panel’s configuration file) is not required to make these changes. The changes made with the Self Configu-ration are saved to that panel’s configuration file when the mode is exited and are persistent. Resetting a BPS panel after a Self Configuration will not change those settings.

The BPS panel default has the Self Configuration feature enabled. This feature can be disabled and so may not be available on a specific BPS panel.

Source Self Configuration

1. Press and hold down the All Lvls/Config button for five seconds. The panel will enter Self Configuration mode and all the Source selection and Level buttons will be illuminated.

2. Press an illuminated Source button. That button will blink.

3. Use the Prev and Next buttons to select a different Source for that button.

4. Press the blinking Source button to assign it that new Source.

5. Press the All Lvls/Config button to exit Self Configuration mode.

Level Self Configuration

Use the procedure above, but press an illuminated Lvl button and then choose an alternative Level with the Prev and Next buttons.

46 Encore — Control Panels Operation Manual

48B Panel

Salvo Self Configuration

If your panel is configured with Salvo selection buttons use the procedure above, but select an illuminated Salvo button and then choose an alterna-tive Salvo with the Prev and Next buttons.

48B Panel

48B Panel Features• 1RU rack mount,

• 48 user defined buttons,

• Default X-Y functionality, program row of Sources and row of Destina-tions,

• Allows Destination ganging (ideal for tape duplication), and

• Grouping with other panels to expand functionality.

48B Panel DescriptionThe 48B (Forty-Eight Button) panel only has programmable buttons and does not have an alphanumeric display (Figure 20).

Figure 20. 48B Control Panel and Default Button Configuration

Source 1 to Source 24

Tally Level

8103_00_38r0

Destination 1 to Destination 19 Level 1 to Level 4

48B Panel Default Button AssignmentsThe default function and selection button configuration for the 48B panel is shown in Figure 20.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Encore — Control Panels Operation Manual 47

Section 3 — Encore Control Panels

Taking a Source to a Destination (48B Panel)1. Press the desired Destination button so it is illuminated.

2. Press the desired Source button. That Source will be immediately taken to that Destination.

Breakaway Take (48B Panel)A breakaway Take switches Sources on only some Destination Levels, leaving the other Levels for that Destination unchanged. You will select the Level(s) to be changed, then Take that Source to only those Destination’s Levels.

1. Press the desired Destination button so it is illuminated.

2. Toggle the Lvl buttons to illuminate the Levels you wish to change.

3. Press the desired Source button. That Source will be immediately taken only to the selected Levels of that Destination.

Note The default panel configuration retains the Levels selected for a breakaway Take for all subsequent Take operations until the Level selections are changed or a different Destination is selected.

Auto Tally and the Tally Level ButtonThe Auto Tally feature automatically tallies the first valid and enabled Level for a Destination. This is useful for breakaway Takes on panels lacking alphanumeric displays, since only one Source button is illuminated at a time. The Auto Tally configuration flag can be turned on and off, and the factory default setting for this feature is ON for 48B panels. When Auto Tally is ON, the Tally Level button, if present on a panel, is disabled.

You can Tally the Source for each Level of a Destination when Auto Tally is ON by disabling the other Levels. The Source button for that remaining enabled Level will be illuminated on the panel.

The priority order of Tally Level reporting when multiple Levels are active is the top down order of Levels in the router configuration. Typically this top down priority order corresponds to a left right order of Level buttons on a panel (Level 1, Level 2, Level 3, etc.). So, for example, if only Levels 2 and 3 are enabled and they are listed in that top down order, Auto Tally would illuminate the Source button for Level 2. Disabling Level 2 in this sit-uation would make the Source button for Level 3 illuminate.

48 Encore — Control Panels Operation Manual

48B Panel

Tally Level Button

The Tally Level button is used to change the Tally Level for the panel. Only the currently selected Level will be tallied.

Note On 48B panels the default setting for Auto Tally flag is ON, which disables the Tally Level button. Make sure Auto Tally is OFF on the configuration being used by the panel if you wish to use the Tally Level button.

Turning the Auto Tally flag OFF activates the Tally Level button, which is assigned to the lower right button by the factory default configuration (see Figure 20 on page 47).

To change the Tally Level of the panel, hold down the Tally Level button and press the Level button of the desired Level. The panel will use that Level for button tally until another Level is selected (or the Auto Tally flag is enabled).

Protect (48B Panel)The default configuration for a 48B panel does not include a Protect button. If your panel has been configured for this feature you can protect and unprotect the currently selected Destination by toggling the Prot button On or Off. The button is illuminated when a Protect is active on the selected Destination.

Salvo (48B Panel)The default configuration for a 48B panel does not include any Salvo but-tons. If your panel has been configured for this feature a Salvo is fired simply by pressing the Salvo button configured for this purpose. Salvo pages are not supported on 48B panels. A separate Salvo button is config-ured for each specific Salvo.

Encore — Control Panels Operation Manual 49

Section 3 — Encore Control Panels

Universal Control Panel (ENC-UCP)

ENC-UCP Panel Features• 2RU half-rack mount,

• Status, Preset, and Level display with three 8-character readouts,

• 16 button programmable keypad (4 rows of four),

• Prev and Next buttons,

• 12 programmable buttons on the left,

• Two looping RS-485 ports with RJ-45 connectors (for Jupiter control using MPK protocol), and

• Server panel operation with Encore Client control panels (see page 52).

ENC-UCP Panel DescriptionThe ENC-UCP panel functions the same as the Encore XY panel, except for fewer programmable buttons, different button locations, and a different half-rack form factor (Figure 15).

Figure 21. ENC-UCP Control Panel

NextNextPrevPrev

SRCSRC

LocalLocal

ChopChop

TakeTakeAllAl l

LevelLevel

Fi l terFi l ter

ProtProt

TakeTake

SalvoSalvo

ShiftShift

DestDest

IDID

CE CE

ClearClear

UNIVERSAL CPUNIVERSAL CP ENCORE/PRELUDE ENCORE/PRELUDEStatusStatus

PresetPreset

Dest /Leve l /AreaDest /Leve l /Area

8053_40r2

Keypad Buttons (16)

Status, Preset, and Level Displays

2-RU Rack Mount Frame (holds two half-rack units)

Programmable Buttons (30)

ENC-UPC Panel Default Button AssignmentsThe default function and selection button configuration for the ENC-UCP panel is shown in Figure 16. The Prev and Next buttons have fixed functions not configurable by the user.

50 Encore — Control Panels Operation Manual

Universal Control Panel (ENC-UCP)

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 22. ENC-UCP Default Button Configuration

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

PDR9PDR9

I

VTR1VTR1

J

VTR2VTR2

K

VTR3VTR3

L

VTR4VTR4

M

VTR5VTR5

N

VTR6VTR6

O

VTR7VTR7

P

DestDest

IDIDLevelLevel SRCSRC

SalvoSalvo

ShiftShift

FilterFilter LocalLocal

ProtProt

CECE

ClearClearTakeTake

8053

_41r

1

Primary Keypad SetProgrammableFunction Buttons

Secondary Keypad SetNotAssigned

ENC-UCP Standalone OperationWhen not configured as a Server/Client group, the ENC-UCP panel oper-ates the same as the Encore XY panel, but with relocated buttons. Refer to XY Panel on page 40 for operating instructions.

Encore — Control Panels Operation Manual 51

Section 3 — Encore Control Panels

Client Control Panel (ENC-CLNT)

Figure 23. ENC-UCP (Left) and ENC-CLNT (Right) Control

NextNextPrevPrev

SRCSRC

LocalLocal

ChopChop

TakeTakeAllAl l

LevelLevel

Fi l terFi l ter

ProtProt

TakeTake

SalvoSalvo

ShiftShift

DestDest

IDID

CE CE

ClearClear

UNIVERSAL CPUNIVERSAL CP ENCORE/PRELUDE ENCORE/PRELUDEStatusStatus

PresetPreset

Dest /Leve l /AreaDest /Leve l /Area

LoadLoad

ProtProt

TakeTake

1

2

2

CLIENT CONTROL PANELCLIENT CONTROL PANEL ENCORE/PRELUDE ENCORE/PRELUDE

3

4

5

6

LoadLoad

ProtProt

TakeTake

1

2

23

4

5

6

LoadLoad

ProtProt

TakeTake

1

2

23

4

5

6

8053_46

UCP Panel Configured as ServerClient Panel

Destination Displays & Keypads (3)

2-RU Rack Mount Frame (holds two half-rack units)

Panels

The ENC-UCP panel can be configured to act as a Server panel. Server and Client Control Panels fill a unique operational niche. The panels are com-plementary. The Server Panel provides quick keypad access to as many as 32 Source and Destination prefixes and suffixes, and Prev/Next scrolling access to all non-excluded system Sources and Destinations. Preset Source names are sent to Client Panels and stored in registers for convenient one-button recall or immediate use. A single Server Panel can be associated with up to 15 Client Panels within a single Client Server Group. Each Client Panel controls three Destinations. Thus, a single Server Panel can be used to set up six Source presets, each for up to forty-five router Destinations. Each preset could include Sources on up to 32 control Levels.

ENC-CLNT ConfigurationTo configure Encore Server Client control panels, the Server is identified as a Master panel, and each Client panel is configured as a member of that master panel’s group. Default Destinations are then assigned to the three Client panel sections using the Default Dst/Page flag.

See the separate Encore Installation & Service Manual for specific configura-tion instructions.

ENC-CLNT Operation

Note If the Client panel is reset, any assigned Destinations are replaced by default Dest/ Page settings, and all Sources are cleared from the numbered buttons.

52 Encore — Control Panels Operation Manual

Client Control Panel (ENC-CLNT)

Changing Destinations on a Client Panel

If you do not want to use a Client panel’s default Destinations, they can be changed with the Server panel.

1. Push Dest/ID on the Server panel to put it into Destination mode.

2. Preset a Destination on the Server panel, using the keypad or the Prev and Next buttons.

3. Press the Load button of the Client panel section you wish to assign that Destination to.

Identifying Assigned Client Panel Destinations

When the Server panel is in Destination mode, pressing the CE/Clear button clears the preset. The three currently assigned Destinations will be reported on those displays.

Assigning Sources to Client Panel Buttons

Once a Server Client panel group is configured, you can preset a Sources on the Server panel and assign them to buttons on the Client panel.

1. Push SRC on the Server panel to put it into Source mode.

2. Preset a Source on the Server panel, using the keypad or the Prev and Next buttons.

3. Press a Client panel section’s Load button, and then press a numbered button (1 - 6). Up to six Sources can be dynamically associated with those buttons for each Client Destination keypad.

Identifying Client Panel Sources

When the Server panel is in Source mode, pressing the CE/Clear button clears the preset. The three Sources for the currently assigned Destinations will be reported on those displays.

Taking a Source to a Destination (CLNT Panel)

To Take a Source to a Destination, touch the numbered register button (1-6), and then touch the blinking Take button on that Destination’s Client panel keypad.

Note Single button Takes is also available on Client panels (see Quick Take Mode below).

Encore — Control Panels Operation Manual 53

Section 3 — Encore Control Panels

Quick Take Mode

A Client panel can be configured for Quick Take mode, by checking this box in the Encore Panel Server Flags and Parameters page for that Client panel. In this mode, pressing a numbered Source button will immediately perform a Take of that Source to that Client panel sections’s Destination.

In this mode, the Protect button changes its function. Pressing this button allows identification of the Source on each keypad button (by pressing that button). Once you have confirmed it is the correct Source, press the Protect button to exit the identification mode, and then press Take or press the blinking button to take that Source to that Destination.

Because the Client panel’s Protect button is unavailable in this mode, Take performed by the Client panel is automatically protected. If you wish to unprotect one of these Destinations, you can use the Encore OUI, or use another panel configured for Protect override.

54 Encore — Control Panels Operation Manual

Section 4SMS7000 GSC Control Panels

IntroductionSMS7000 Global Serial Channel (GSC) control panels can be used with an Encore version 1.7 or higher system. The control panel’s internal software needs to updated for use with Encore and a GSC mezzanine must be installed in the Encore System Controller. SMS7000 GSC control panels connect to Encore via the GSC BNC connectors on the rear panel of the Encore System Controller frame. Each of the four GSC busses support up to 16 SMS7000 control panels for a total of 64 per Encore System Controller.

Because the GSC panels do not use Ethernet these panels are not visible to the Grass Valley NetConfig application. GSC panel software cannot be updated using NetConfig, but instead a PC and a direct serial connection are used. See the Encore Release Notes for the latest installation and software update procedures.

Once installed with the Encore software, GSC panels are configured the same as other Encore panels, using the Encore Panel Server application. See the Encore Configuration Manual for additional information.

In general, SMS7000 panel functionality under Encore does not mimic func-tionality under SMS7000 control; rather it is based on the existing function-ality of the equivalent Encore control panel type.

All Encore system Control Panels support Chop except the CLNT/SVR and MCO/COS custom panels.

Because the GSC panels use older hardware and communication methods, their operating response will be slower than newer Encore control panels.

Encore — Control Panels Operation Manual 55

Section 4 — SMS7000 GSC Control Panels

UCP Panel

UCP Panel Features• 2RU half-width rack mount,

• Status, Preset, and Level alphanumeric displays,

• Access to all Destinations and Sources,

• 26 programmable buttons,

• 16 button user-defined prefix /suffix keypad, and

• Previous / Next scrolling within prefix group.

UCP Panel DescriptionThe UCP (Universal Control Panel) has a group of programmable buttons on the left, three alphanumeric displays in the center, and a programmable keypad on the right (Figure 24).

Figure 24. UCP - Universal Control Panel

8053_20r0

STATUSRemt 3

PRESETRemt 3

LEVELRemt 3

DESTID

LEVEL SRC

PREVSALVO NEXT

CECLEAR

PROT

TAKE

CHOP

UCP Panel Default Button AssignmentsThe default button configuration for the UCP panel is shown in Figure 25.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

56 Encore — Control Panels Operation Manual

UCP Panel

Figure 25. UCP Panel, Default Button Configuration and Keypad Sets

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

PDR9PDR9

I

VTR1VTR1

J

VTR2VTR2

K

VTR3VTR3

L

VTR4VTR4

M

VTR5VTR5

N

VTR6VTR6

O

VTR7VTR7

P

DESTDESTIDID

LEVELLEVEL SRCSRC

SALVOSALVO PREVPREV NEXTNEXT

PROTPROT CHOPCHOP

TAKETAKE

CECECLEARCLEAR

8053

_21r

0

Primary Keypad SetProgrammableFunction Buttons

Secondary Keypad Set

The Secondary Keypad set will only be available on the panel if the default configuration is changed to include a Shift button.

Note The PREV and NEXT buttons are not equipped with LEDs and so will not tally if programmed for a different function.

Taking a Source to a Destination (UCP Panel)1. Press the DEST/ID button to enter Destination mode.

2. Use the PREV and NEXT buttons to show the desired Destination on the Preset display.

3. Press the TAKE button to assign that Destination to the Status display.

4. Press the SRC button to enter Source mode.

5. Use the PREV and NEXT buttons to show the desired Source on the Preset display.

6. Press the TAKE button. The new Source is taken to that Destination and that Source’s name is reported in the status display.

Note A panel’s configuration may exclude control of some Sources, Destinations, and Levels. Excluded items will not be selectable in the Preset display.

Breakaway Take (UCP Panel)1. Press the DEST/ID button to enter Destination mode.

2. Use the PREV and NEXT buttons to show the desired Destination on the Preset display.

3. Press the TAKE button to assign that Destination to the Status display.

Encore — Control Panels Operation Manual 57

Section 4 — SMS7000 GSC Control Panels

4. Press the LEVEL button to enter Level mode.

5. Use the PREV and NEXT buttons to show each Level in turn on the Level display. Press the TAKE button so it is illuminated to select the Levels you wish to change for that Destination. At least one Level must be selected.

6. Press the SRC button to enter Source mode.

7. Use the PREV and NEXT buttons to show the desired Source on the Preset display.

8. Press the TAKE button. The new Source is taken only on the selected Levels of that Destination.

Protect (UCP Panel)

Note With default panel configurations, only the control panel that set the Protect can unprotect that Destination. When a Protect has been set, the PROT button on the panel that set the Protect will blink, and the PROT buttons on other panels accessing that Destination will be illuminated without blinking.

Note Pressing and holding a steadily illuminated PROT button on a panel with a text display will report the name of the panel that set the Protect.

1. Press the DEST/ID button to enter Destination mode.

2. Use the PREV and NEXT buttons to show the desired Destination on the Preset display.

3. Toggle the PROT button to turn Protect On (illuminated) or Off for that Destination.

Note UCP panels do not report Protects for Destinations not currently assigned to the Status display. Care should be taken to relinquish all unneeded Protects before changing Destinations on these panels. You should also remember to free up all Destinations no longer requiring protection before you leave the vicinity of the panel.

Salvo (UCP Panel)When a UCP panel has been configured with Salvo capabilities, you will be able to select a Salvo and execute it.

CAUTION Be sure you understand exactly what a Salvo will do before you use it, and only fire a Salvo when it is appropriate to do so. Changing multiple Destina-tions with a Salvo can have far-reaching consequences, including possibly disrupting on-air operations.

1. Press the SALVO button to enter Salvo mode.

58 Encore — Control Panels Operation Manual

CLNT Panel

2. Use the PREV and NEXT buttons to show the desired Salvo on the Preset display.

3. Press the TAKE button to fire the selected Salvo.

CLNT PanelThe SMS-7000 Client panel is available for use as a member of a group with an SMS-7000 UCP configured as a Server (Figure 26).

Figure 26. UCP and CLNT Control Panel Group

8053_55r0

Grass Valley

PRESETRemt 3

LEVELRemt 3

DESTID

LEVEL SRC

PREVSALVO NEXT

CECLEAR

SHIFT

TAKEALL

CHOP

Grass Valley

Remt 3

LOAD 4

PROT 5

TAKE 6

1

2

3

LOAD 4

PROT 5

TAKE 6

1

2

3

LOAD 4

PROT 5

TAKE 6

1

2

3

Remt 3 Remt 3

Series 7000

Series 7000

The configuration and operation of this panel is similar to the Encore UCP/CLNT group. Refer to Client Control Panel (ENC-CLNT) on page 52.

P32 Panel

P32 Panel Features• 1RU rack mount,

• Alphanumeric status display, and

• 36 user-defined programmable buttons.

P32 Panel DescriptionThe P32 (Programmable 32 button) panel was originally designed to control the routing of a limited number of Sources to a single Destination with a single button press. The default configuration has a minimal number of function buttons on the left, a single alphanumeric display, and Source selection buttons on the right (Figure 27).

Encore — Control Panels Operation Manual 59

Section 4 — SMS7000 GSC Control Panels

Figure 27. P32 - Programmable Button-Per-Source Control Panel

8053_24r0

Bobs Cam

SRCID

LEVELINV

PROT

CHOP

Under Encore control all the P32 panel buttons can be programmed for dif-ferent functions or Source selections, including the selection of Destina-tions. This section describes only the panel’s default behavior of controlling a single Destination.

P32 Panel Default Button AssignmentsThe default button configuration for the P32 panel is shown in Figure 28.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 28. P32 Panel, Default Button Configuration and Keypad Sets

SRCSRCIDID

PROTPROT

CHOPCHOP LEVELLEVELINVINV

8053

_25r

0

Right 32 Buttons Default ConfigurationTop Row: Source 1-16

Bottom Row: Source 17-32

ProgrammableFunction Buttons

Taking a Source to a Destination (P32 Panel)Press the button for the desired Source. It will immediately be taken to the Destination and the name of the Source appears in the status display.

Breakaway Take (P32 Panel)1. Press the LEVEL/INV button to enter Level mode. In this mode the buttons

on the right no longer select Sources. The first upper row buttons now correspond to the Levels available and will be illuminated when they have been selected.

2. Press the selection buttons to toggle the desired Levels On or Off.

Note Pressing the LEVEL/INV button when it is illuminated will swap the Level selections (On Levels go Off, and Off Levels go On).

60 Encore — Control Panels Operation Manual

MB8 Panel

3. Press the SRC/ID button to enter Source mode.

4. Press the desired Source button. The new Source is taken only to the selected Levels of that Destination.

Protect (P32 Panel)Toggle the PROT button to turn Protect On (illuminated) or Off for that Des-tination.

Note With default panel configurations only the control panel that set the Protect can unprotect that Destination. When a Protect has been set the PROT button on the panel that set the Protect will blink, and the PROT buttons on other panels accessing that Destination will be illuminated without blinking.

Note Pressing and holding a steadily illuminated PROT button on a panel with a text display will report the name of the panel that set the Protect.

MB8 Panel

Figure 29. MB8 - Programmable Multibus 8 Control Panel

8053_21r0

PRESET

Remt 3

LEVEL

DigVideo

DESTID

LEVEL SRC

PREVSALVO NEXT

CECLEAR

STO

RCL

CHOP

STATUS 1

VTR 12

PROT

TAKE

STATUS 5

Black

PROT

TAKE

STATUS 2

PROT

TAKE

STATUS 6

PROT

TAKE

STATUS 3

PROT

TAKE

STATUS 7

PROT

TAKE

STATUS 4

PROT

TAKE

STATUS 8

PROT

TAKE

VTR 6

Netwk

Remt 7

DVE 2

DiskRcdr

CGEN 4

The SMS7000 MB8 (Multi-Bus 8) panel operates essentially the same as an Encore PMB panel, except it has two fewer programmable buttons on the left and the default button configuration is slightly different.

Default Button Configuration (MB8 Panel)The default button configuration for the MB8 panel is shown in Figure 30.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Encore — Control Panels Operation Manual 61

Section 4 — SMS7000 GSC Control Panels

Figure 30. MB8 Panel, Default Button Configuration and Keypad Sets

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

PDR9PDR9

I

VTR1VTR1

J

VTR2VTR2

K

VTR3VTR3

L

VTR4VTR4

M

VTR5VTR5

N

VTR6VTR6

O

VTR7VTR7

P

DESTDESTIDID

LEVELLEVEL SRCSRC

SALVOSALVO PREVPREV NEXTNEXT

SHIFTSHIFT

CECECLEARCLEAR

DESTDESTPAGEPAGE

LEVELLEVELPAGEPAGE

8053

_23r

0

Primary Keypad SetProgrammableFunction Buttons

Secondary Keypad Set

The Secondary Keypad set will only be available on the panel if the default configuration is changed to include a Shift button.

Note The PREV and NEXT buttons are not equipped with LEDs and so will not tally if programmed for a different function.

MB8 Panel OperationThe procedures for Takes, Protects, and Salvos are the same as those used on an Encore PMB panel. See PMB Panel on page 34 for operational infor-mation.

MB4 Panel

MB4 Panel DescriptionThe Multibus 4 Control Panel (MB4) controls four assigned output busses (Destinations). Status information and destination names are simultane-ously displayed, eliminating much mode switching. Destinations are typi-cally front-panel selectable so the MB4 can switch any Source to any Destination, depending on configuration.

A 16-button configurable keypad provides prefix/suffix access to fre-quently used sources and destinations. You can also scroll through com-plete name lists using the PREV and NEXT buttons. Destination Page Mode is also available for scrolling through Destination Pages applied to that panel.

62 Encore — Control Panels Operation Manual

MB4 Panel

Figure 31. MB4 - Programmable Mulitbus 4 Control Panel

Grass Valley

PRESET

Remt 3

LEVEL

DigVideo

DESTID

LEVEL SRC

PREVSALVO NEXT

CECLEAR DST PG

DST PG

CHOP

STATUS 1

VTR 12

PROT

TAKE

DEST 1

Black

HOLD

LOAD

STATUS 2

PROT

TAKE

DEST 2

HOLD

LOAD

STATUS 3

PROT

TAKE

DEST 3

HOLD

LOAD

STATUS 4

PROT

TAKE

DEST 4

HOLD

LOAD

VTR 6

Netwk

Remt 7

DVE 2

DiskRcdr

CGEN 4

Series 7000

8053_47r0

Default Button Configuration (MB4 Panel)The default button configuration for the MB4 panel is shown in Figure 30.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration.

Figure 32. MB4 Panel, Default Button Configuration and Keypad Sets

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

PDR9PDR9

I

VTR1VTR1

J

VTR2VTR2

K

VTR3VTR3

L

VTR4VTR4

M

VTR5VTR5

N

VTR6VTR6

O

VTR7VTR7

P

DESTDESTIDID

LEVELLEVEL SRCSRC

SALVOSALVO PREVPREV NEXTNEXT

SHIFTSHIFT

CECECLEARCLEAR

DESTDESTPAGEPAGE

LEVELLEVELPAGEPAGE

8053

_23r

0

Primary Keypad SetProgrammableFunction Buttons

Secondary Keypad Set

MB4 Panel OperationThe MB4 Control Panel operates similar to the MB8 Control Panel, except four Destinations are accessible at a time, status is available for both Desti-nations and Sources, and the addition of Hold and Load buttons for each Des-tination.

Hold Button

Press the Hold button so it is illuminated to keep that Destination assigned to that display area. Selecting new pages of Destinations will not change panel control of held destinations.

Encore — Control Panels Operation Manual 63

Section 4 — SMS7000 GSC Control Panels

Load Button

Pressing the Load button loads the currently preset Destination to that Control Panel display, provided a Hold is not active.

The Dest Page down button is not available. Destinations are chosen via paging using the upper Dest button, or via keypad, using the Prev/Next but-tons, or with assigned Destination buttons.

EDP Panel

Figure 33. EDP -Eight Destination Paging Control Panel

PRESET

LEVEL

Satt13

NTSC Vid

DESTID

LEVEL SRC

LEVELPAGE

DESTPAGE

STORE

SRCPAGE

SALVOPAGE

SHIFTA

CHOP

CECLEAR

SHIFTB

STATUS 1

DEST 1

CAMERA1

DVTR1

PROTHOLD

TAKELOAD

STATUS 2

DEST 2

CAMERA2

DVTR2

PROTHOLD

TAKELOAD

STATUS 3

DEST 3

CAMERA3

DVTR3

PROTHOLD

TAKELOAD

STATUS 4

DEST 4

CAMERA5

DVTR4

PROTHOLD

TAKELOAD

STATUS 5

DEST 5

CAMERA8

DVTR5

PROTHOLD

TAKELOAD

STATUS 6

DEST 6

DiskRcdr

DVTR6

PROTHOLD

TAKELOAD

STATUS 7

DEST 7

netwk144

DVTR7

PROTHOLD

TAKELOAD

STATUS 8

DEST 8

Remote21

DVTR8

PROTHOLD

TAKELOAD

PREV NEXT

8053_26r0

EDP Panel OperationThe SMS7000 EDP (Eight Destination Paging) panel operates essentially the same as an Encore PMB panel. The same default button configuration is used (Figure 34), and the procedures for Takes, Protects, and Salvos are the same, with one exception. The EDP panel uses a knob instead of Prev or Next buttons to scroll through the available items.

See PMB Panel on page 34 for operational information.

64 Encore — Control Panels Operation Manual

P48 Panel

Default Button Configuration (EDP Panel)

Figure 34.

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

PDR9PDR9

I

VTR1VTR1

J

VTR2VTR2

K

VTR3VTR3

L

VTR4VTR4

M

VTR5VTR5

N

VTR6VTR6

O

VTR7VTR7

P

DestDest

IDID

LevelLevel SrcSrc

DestDestPagePage

LevelLevelPagePage

SrcSrcPagePage

SalvoSalvoPagePage

ChopChop

CECE

ClearClear

ShiftShift

8053

_10r

0

Primary Keypad SetNotAssigned

ProgrammableFunction Buttons

Secondary Keypad Set

EDP Panel Button Defaults (Same as Encore PMB Panel)

P48 Panel

Figure 35. P48 - 48 Button-Per-Source Control Panel

PROT CHOPID

TALLYLEVEL

ALLLVLS

LVL1

LVL2

LVL3

LVL4

LVL6

LVL5

8053_33r0

P48 Panel OperationThe SMS7000 P48 (Programmable 48 button) panel operates the same as an Encore BPS panel. The same default button configuration is used (Figure 36), and the procedures for Takes, Protects, and Salvos are the same.

See BPS Panel on page 44 for operational information.

Default Button Configuration (P48 Panel)

Figure 36.

ProtProt

Lvl 1Lvl 1

ChopChop

Lvl 2Lvl 2 Lvl 3Lvl 3 Lvl 6Lvl 6Lvl 4Lvl 4

PrevPrev

All LvlsAll Lvls

ConfigConfig

TallyTally

IDID

Lvl 5Lvl 5

NextNext

Right 48 Buttons Default Configuration Top Row: Source 1 - 24

Bottom Row: Source 25 - 48

8053

_19r

0

P48 Panel Button Defaults (Same as Encore BPS Panel)

Encore — Control Panels Operation Manual 65

Section 4 — SMS7000 GSC Control Panels

PXY Panel SetThe PXY Panel Set consists of:

• PXS Master panel (typically configured with sources)

• PXD Expansion panel (typically configured with destinations)

• PXYE panel for Source, Salvo, or Destination Expansion

Figure 37. PXY Control Panel Group

8053_48r0

Bobs CamDESTINATION

Grass Valley

Series 7000

Bobs CamSOURCE

Grass ValleyNEXTSRC

NEXTDST

PREVSRC

PREVDST

SRCID

LEVELINV

PROT

CHOP

Series 7000

Bobs CamDESTINATION

Grass Valley

ID

Series 7000

PXS

PXYE

PXD

PXY Panel Set Features• The PXS can function alone or can work with one or more PXYE panels

and/or a single PXD panel. PXD and PXYE panels will not function without a PXS panel.

• All Control Panel buttons are programmable.

PXY Panel Set ConfigurationTo configure a PXY Panel set, the PXS panel is identified as a Master panel, and each PXD/PXYE panel is configured as a member of that Master panel’s group. See the separate Encore Installation & Service Manual for spe-cific panel group configuration instructions.

PXY Group Default Button Assignments

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration.

66 Encore — Control Panels Operation Manual

PXY Panel Set

PXS Default Button Assignments

Figure 38. PXS Panel, Default Button Configuration

SRCSRCIDID

PROTPROT

CHOPCHOP LEVELLEVELINVINV

PrevPrevSRCSRC

NextNextSRCSRC

PrevPrevDSTDST

NextNextDSTDST

8053

_52r

0

Right 32 Buttons Default ConfigurationTop Row: Source 1-16

Bottom Row: Source 17-32

With LEVEL selected:Levels 1-32

PXD Default Button Assignments

The Left eight buttons by default are configured as Level Select 1 - 8. The remaining buttons by default are configured as Destination 1-32.

PXYE Default Button Assignments

The isolated button on the left by default is configured as an ID button. The remaining buttons by default are configured as Destination 1-32.

PXS Source/Level Mode SelectionThe PXS panel typically has two modes of operation (Source mode and Level mode), selected with the SRC/ID and LVL/INV buttons.

• When SRC/ID is illuminated, the buttons on the right select Sources, Des-tinations, or Salvos, as configured.

• When LVL/INV is illuminated, the buttons on the right select Levels.

Taking a Source to a Destination (PXS Panel)1. Press the SRC/ID button, if necessary, to enter Source mode.

2. Press and hold the Prev DST or Next DST button until the name of the desired Destination is shown on the display.

3. Release the button to select that Destination for control.

4. Select the Source:

• Press a Source button on the right. That Source will immediately switch to the selected Destination.

- or -

a. Press and hold the Prev SRC or Next SRC button until the name of the desired Source appears on the display.

b. Release the button to Take that Source to the selected Destination.

Encore — Control Panels Operation Manual 67

Section 4 — SMS7000 GSC Control Panels

Taking a Source to a Destination (PXY Panel Group)Typically additional Destinations are configured on the PXD panel. Pressing a Destination button on the PXD panel in the group selects that Destination for control.

Typically additional Sources are configured on the PXYE panel. Pressing one if those buttons will Take that Source to the selected Destination.

Breakaway Take (PXS Panel)Breakaway Takes are performed the same as on a P32 Control Panel.

1. Press the LEVEL/INV button to enter Level mode. In this mode the buttons on the right no longer select Sources. The buttons now correspond to the Levels available and will be illuminated when they have been selected.

2. Press the selection buttons to toggle the desired Levels On or Off.

Note Pressing the LEVEL/INV button when it is illuminated will swap the Level selections (On Levels go Off, and Off Levels go On), provided the Level Inverse Lock flag is turned off in that panel’s configuration.

3. Press the SRC/ID button to enter Source mode.

4. Press the desired Source button, or scroll through the available Sources. The new Source is taken only to the selected Levels of that Destination.

Protect (PXS Panel)Toggle the PROT button to turn Protect On (illuminated) or Off for that Des-tination.

SCP - Simple Control Panel

SCP Panel DescriptionThe Simple Control Panel (SCP) is a hybrid mode panel that supports both keypad access of Sources and button-per-item access of Sources, Destina-tions, Salvos or Levels in any combination. The panel may control a single Destination, multiple Destinations, and from one to all system Levels (defined by the user during system configuration). The SCP also offers Protect and other functions.

68 Encore — Control Panels Operation Manual

SCP - Simple Control Panel

Figure 39. SCP - Simple Control Panel

8053_49r1

ON = PRESETOFF = STATUS

Bobs Cam

Grass Valley

ID

CLEARPROT

TAKE

Series 7000

Default Button Configuration (SCP Panel)The default button configuration for the SCP panel is shown in Figure 30.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration.

Figure 40. SCP Panel, Default Button Configuration and Keypad Sets

AUXAUX

9

BLACKBLACK

8

BARSBARSEDITEDIT

7

CARTCARTSTUSTU

0

testtestFSFS

VCRVCR

6

ENGENG

5

CAMCAMCGCG

4

NETNET

3

PDRPDR

2

REMREMVTRVTR

1

PDR1PDR1

A

PDR2PDR2

B

PDR3PDR3

C

PDR4PDR4

D

PDR5PDR5

E

PDR6PDR6

F

PDR7PDR7

G

PDR8PDR8

H

IDID

CLEARCLEARPROTPROT

TAKETAKE

SRCSRC1

DSTDST1

SRCSRC2

DSTDST2

SRCSRC3

DSTDST3

SRCSRC4

DSTDST4

8053

_53r

1

Keypad Set (or Programmable Buttons)

ProgrammableButtons

ProgrammableButtons

Status Display

SCP Panel OperationThe SCP operates similar to other SMS7000 model Control Panels, with the following differences:

• The Keypad Set consists of the Primary set (left 16 buttons) and half of the Secondary set (right 8 buttons). Shift functionality is not supported.

• Only Source selections can be preset using the keypad, for subsequent activation with the Take button.

• Destination and Salvo selections are always immediately executed.

• Shift Latching is not supported.

Encore — Control Panels Operation Manual 69

Section 4 — SMS7000 GSC Control Panels

70 Encore — Control Panels Operation Manual

Section 5Kalypso Remote Aux Panels

IntroductionKalypso 32 button Remote Aux Panels can be used with an Encore version 1.7 or higher system. Older model Kalypso Aux Panels may need to have their software updated in order to work on an Encore system. See the Encore Release Notes for the latest installation and software update proce-dures. Once installed with the Encore software, Kalypso Remote Aux panels are configured the same as other Encore panels, using the Encore Panel Server application. See the Encore Configuration Manual for additional information.

Key Features• Web browser-based setup,

• 10Base-T Ethernet RJ-45 control interface, includes active and collision indication,

• Internal auto-ranging AC mains power supply,

• Back-lit buttons with display intensity adjustments,

• All buttons programmable, and

• Simple name-based identification.

Encore — Control Panels Operation Manual 71

Section 5 — Kalypso Remote Aux Panels

Remote Aux Panel Model TypesTwo different Remote Aux Panel models exist. Different names have been used for the documentation of these panels, depending on whether they are part of a Kalypso system or an Encore system.

• KAL-32AUX1, the original model name used for the 1RU Kalypso Remote Aux Panel, corresponds to the KSD (Kalypso Single Destina-tion) panel when used with Encore.

• KAL-32AUX2, the original model name used for the 2RU Kalypso Remote Aux Panel, corresponds to the KMD (Kalypso Multi Destina-tion) panel when used with Encore.

Note Because all the buttons on the KSD and KMD panels are programmable, it is possible to configure either panel for either single or multiple Destination control.

The Encore Panel Server OUI identifies Kalypso panels as KSD or KMD, and these terms are used in this section.

KMD PanelThe KMD panel has a group of 48 programmable buttons on the left (typi-cally used for selections), and a status display and ten programmable buttons on the right (typically used for functions). See Figure 41.

Figure 41. KMD Remote Aux Panel

KALYPSO REMOTE AUX PANEL

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 M/E1

M/E2

M/E3

PgmPst

Hold

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Un-Shift

Shift KeySplit

NearSide

FarSide

AUX1

AUX2

AUX3

AUX4

AUX5

AUX6

AUX7

AUX8

AUX9

AUX10

AUX11

AUX12

AUX13

AUX14

AUX15

AUX16

Display Functionalityof BPS32

Function Buttons (10)Selection Buttons (48)

8053_27r0

The control panel button and display functionality of the KMD panel is modeled on the Encore BPS panel.

72 Encore — Control Panels Operation Manual

KMD Panel

KMD Panel IDThe KMD panel alphanumeric displays can report the following informa-tion for that panel.

• Panel IP Address

• Panel Name

• Controlled Destination Area

• Controlled Destination Name

• Name of the Panel Destination

• Name of the Current Tally Level

• Protect Override, if set

Holding down the Tally/ID button activates the panel ID mode.

You can interrupt the ID display sequence at any time by pressing any button to resume normal operation. It is not necessary to let the identifica-tion routine finish.

Default Button Configuration (KMD)The default button configuration for the KMD panel is shown in Figure 42.

Note Button assignments for a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Configuration Manual for more information.

Figure 42. KMD Default Button Configuration

ProtProt

Lvl 1Lvl 1

ChopChop

Lvl 2Lvl 2 Lvl 4Lvl 4

PrevPrev

All LvlsAll Lvls

ConfigConfig

TallyTally

IDID

Lvl 5Lvl 5

NextNext

Left Buttons Default Configuration Top Row: Source 1 - 16

Middle Row: Source 17 - 32Bottom Row: Source 33 - 48

8053

_30r

0

Not Assigned

KMD Panel OperationThe procedures for Takes, Protects, and Salvos are the same as those used on an Encore BPS panel. See BPS Panel on page 44 for operational informa-tion.

Encore — Control Panels Operation Manual 73

Section 5 — Kalypso Remote Aux Panels

KSD PanelThe KSD panel has 42 programmable buttons. The 32 on the left are typi-cally used for selections and the ten on the right are typically used for func-tions (Figure 43).

Figure 43. KSD Remote Aux Panel

KALYPSO REMOTE AUX PANEL

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 M/E1

M/E2

M/E3

PgmPst

Hold

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Un-Shift

Shift KeySplit

NearSide

FarSide

8053_28r0

Function Buttons (10)Selection Buttons (32)

The control panel button functionality for the KSD panel is modelled on the Encore 48B panel except it has six fewer buttons.

Default Button Configuration (KSD)The default button configuration for the KSD panel is shown in Figure 44.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 44. KSD Default Button Configuration

SrcSrc

1717

SrcSrc

1818

SrcSrc

1919

SrcSrc

2020

SrcSrc

1 1

Lvl 1Lvl 1 Lvl 2Lvl 2 Lvl 3Lvl 3 TallyTallyLevelLevel

Left Buttons Default Configuration Top Row: Source 1 - 16

Bottom Row: Destination 1 - 16 80

53_3

1r0

Not Assigned

KSD Panel OperationThe KSD operating procedures are the same as those used on an Encore 48B panel. See 48B Panel on page 47 for operational information.

74 Encore — Control Panels Operation Manual

Section 6Acappella Control Panels

IntroductionAcappella remote panels can be used with an Encore systems. Older remote panels may need to have their software updated in order to work on an Encore system. See the Encore Release Notes for the latest installation and software update procedures. Once installed with the Encore software, Aca-ppella remote panels are handled by the Encore system the same as Encore 48B panels. See the Encore Configuration Manual for additional information.

Key Features• Web browser-based setup,

• 10Base-T Ethernet RJ-45 control interface, includes active and collision indication,

• Back-lit buttons with display intensity adjustments,

• All buttons programmable, and

• Simple name-based identification.

Acappella Remote Panel TypesSeveral different types of Acappella remote panels exist that are equipped with different sets of Source and Destination buttons. All Acappella remote panels have four Level buttons, a green Enable button, a red Protect button. Three representative panels are shown below. Figure 45 is a panel with 16

Encore — Control Panels Operation Manual 75

Section 6 — Acappella Control Panels

Sources and 16 Destinations. Note that under Encore control all buttons are configurable, and so may perform different functions.

Figure 45. 16x16 Remote Panel

8053_05r0

Figure 46 is a panel with 16 Sources and 8 Destinations.

Figure 46. 16x8 Remote

8053_34r0

Panel

Figure 47 is a panel with 8 Sources and 1 Destination.

Figure 47. 8x1 Single Destination Remote Panel

8053_34r0

Acappella remote panels are treated as ENC-48B panels by the Encore system. On-line Acappella remote panels are listed in the Panel Server GUI as ENC-48B panel types. The existing 48B panel configuration editor graphics and templates are used to program these panels, which display the maximum number of buttons.

Acappella Local PanelsAn Acappella matrix may be equipped with a local panel. Local panel buttons are incorporated into the front of the Acappella matrix frame.

Though the button layout and appearance of an Acappella local panel is similar to the Acappella remote panels described in this section, they are fundamentally different. Local panels are dedicated to only the Acappella matrix frame they are incorporated into and cannot be configured (except to support Level operation in conjunction with other Acappella matrix frames).

76 Encore — Control Panels Operation Manual

Default Button Configuration (Acappella Remote Panel)

Acappella local panel selection buttons are dedicated to specific Source and Destination connectors on that Acappella matrix, and cannot be used to switch crosspoints on other Encore system matrices.

If an Acappella matrix equipped with a local panel is part of an Encore system, the buttons on the local panel will be functional and can be used to change that matrix’s crosspoints. The status of these changes will also be reported on other Encore system panels configured to control the Sources and Destinations of that Acappella matrix.

Refer to the separate Acappella Instruction Manual for more information about Acappella matrix frames and local panels.

Default Button Configuration (Acappella Remote Panel)The default button configuration for all Acappella Remote Panels is the same as the Encore 48B panel, as is shown in Figure 48.

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 48. Acappella Remote Panel Default Button Configuration

8053_32r0

Source 1 to Source 16 Sources 17 through 24, Destination 17, Level 3 configured but no buttons exist

Tally Level

Dest 18

Dest 19

Level 1

Level 2

Level 4Destination 1 to Destination 16

Buttons not present on a given Acappella panel can be programmed but obviously will not be usable since the buttons don’t actually exist. Knowing which buttons are available on a particular Acappella remote panel type is required when these panels are programmed.

Note It may be useful to create control panel templates (from the basic 48B tem-plate) for each type of Acappella panel used. The appropriate functions can be assigned to buttons present on the panel, and buttons that do not exist could be configured as Not Assigned.

Encore — Control Panels Operation Manual 77

Section 6 — Acappella Control Panels

Acappella Remote Panel OperationThe procedures for Takes, Protects, and Salvos are the same as those used on an Encore 48B panel. See 48B Panel on page 47 for operational informa-tion.

78 Encore — Control Panels Operation Manual

Section 7JEP-100 Panel

IntroductionThe JEP-100 control panel is a locally-programmable, eight-character dis-play, full-matrix control, multiple Level break away panel. It was designed to operate with either Encore or Jupiter control systems.

The JEP-100 panel includes a fully-enclosed auto-sensing power supply. The panel has no power switch (the AC cord is disconnected to power down the panel).

JEP-100 Panel Features• 2 RU rack mount,

• Four alpha-numeric displays for status reporting,

• 96 programmable buttons, typically used for Source, Destination, and Level selection, and 12 additional programmable buttons, typically used for functions, and

• Joystick override.

SpecificationsPhysical Dimensions: 2 RU rack mount: 19 in. W x 3.5 in. H x approx. 4 in. D (483 mm W x 89 mm H x 102 mm D)

Weight: 2.25 lb. (1.02 kg.)

Operating voltage: 90 to 260 VAC

Operating current: 0.4 A @ 240 VAC or 0.65 A @ 120 VAC

Inrush current rating: 7.9 A

Power consumption: <100 W

Joystick override: Connector, 15-pin D, female.

Encore — Control Panels Operation Manual 79

Section 7 — JEP-100 Panel

Wiring between rear-panel connector and customer-supplied contact closure device: minimum 22 AWG (American Wire Gauge); maximum length, 30 feet (10 meters).

JEP-100 Panel DescriptionThe 96 buttons on the left of the panel can be programmed for any function. Typically the majority of these buttons are used for Source selection, but they may be assigned to control Destinations, Levels, or Salvos. The four displays report the names of the current Destination, Status (current Source routed to that Destination), Preset, Level, and menu information (Figure 49).

Figure 49. JEP-100 Control Panel

Destination

Status

Preset

Level

8053_44r0

Level Salvo Pst

Lock Dest Src

Down Clear Take

Up MenuAssignand

Select

1 2 3 4 5 6 7 8 9 10 11 12 13 14 21 22 23 24

45 46 47 48

15 16 17 18 19 20

71 7269 70

25 26 27 28 29 30 31 32 33 34 41 42 43 44

95 9693 94

35 36 37 38 39 40

91 9289 9085 86 87 8873 74 81 82 83 8475 76 77 78 79 80

65 66 67 6849 50 51 52 53 54 61 62 63 6455 56 57 58 19 60

Function Buttons (12)Programmable Buttons (96)

Destination, Status, Preset, and Level Displays

Note The JEP-100 panel can also be configured to display Level tally on the dis-plays. See the separate Encore Configuration Manual for specific information.

JEP-100 Default Button ConfigurationThe panel ships from the factory with numbered buttons installed on the left, and buttons on the right have legends showing default panel func-tions. All buttons are programmable.

80 Encore — Control Panels Operation Manual

JEP-100 Operation

Note Button assignments of a particular control panel may be different because the defaults can be changed during configuration. See the separate Encore Con-figuration Manual for more information.

Figure 50. JEP-100 Default Button Legends

46

COLORBAR

VTR001

VTR002

VIDEO

8053

_45r

0

24 Level Salvo Pst

Lock Dest Src

UpAssign

andSelect

Menu

Down Clear Take

23

4847

7271

9695

22

70

94

Destination

Status

Preset

Level

JEP-100 Operation

Selecting a Destination to ControlIf the desired Destination button is assigned, press the button of the Desti-nation you wish to control so it is illuminated.

If the Destination you wish to control is not assigned to a button, you can select it from a list of available Destinations.

1. Press Dest.

2. Use the Up and Down buttons to scroll to the desired Destination reported in the Preset window.

3. Press Take. The panel can now be used to control that Destination.

Encore — Control Panels Operation Manual 81

Section 7 — JEP-100 Panel

Taking a Source to a Destination

Using Assigned Buttons

1. Press the assigned button of the desired Destination. It’s name will be reported in the Destination window.

2. Press the assigned button of the desired Source. It will immediately be routed to that Destination and its name will appear in the Source window.

Using Scrolling Lists

1. Press the Dest button so it is illuminated.

2. Use the Up and Down buttons to scroll through the list of available Destinations, stopping when the desired one appears in the Destination window.

3. Press Take to select that Destination for control.

4. Press the Src button.

5. Use the Up and Down buttons to select the desired Source (its name will appear in the Source window).

6. Press Take. That Source will be routed to the selected Destination.

Breakaway Take (JEP-100 Panel)

Using Assigned Buttons

1. Select a Destination to control (see above).

2. Press the assigned buttons for the Levels you wish to change so only those buttons are illuminated.

3. Select a Source (see above). Only the selected Level’s Sources will switch.

Using Level Mode

1. Select a Destination to control (see above).

2. Press Level to enter Level mode.

3. Use the Up and Down buttons to scroll through the available Levels. When the Level name is shown in the Level window, press the Take button so that button illuminates. This selects that Level for control.

82 Encore — Control Panels Operation Manual

JEP-100 Operation

4. Confirm only the desired Levels have been selected, by scrolling through Scrolling through the list of Levels. The Take button will go on and off as each Level is selected.

5. Press Src to exit Level mode and enter Source Selection mode.

6. Select the desired Source, using an assigned button or by scrolling through the list of available Sources (see above). Only the selected Levels will change to the new Source.

Locking or Protecting a DestinationThe JEP-100 panel can be configured for Protect, Soft Lock, or Hard Lock capabilities (see the Encore Configuration Manual). One form of Destination lock or Protect can be enabled at a time. Protect is the default setting.

To Protect or lock a Destination, select the Destination for control and press press the Lock button so it is illuminated. Other panels (without override capabilities) will not be able to change that Destination.

To unlock or unprotect the Destination, press the Lock button again so it turns off.

SalvosButtons on the JEP-100 can be assigned to execute a Salvo.

Salvos that are not assigned can also be executed by selecting them from a list.

1. Press the Salvo button so it is illuminated.

2. Use the Up and Down buttons to scroll through the list of available Salvos and select the one desired.

3. Press Take to execute the Salvo.

Front Panel Button AssignmentButtons can be assigned using the JEP-100 front panel controls (provided the Panel Server Self Config Lock flag is turned off). These configuration changes are saved to that panel’s configuration stored on the Encore Panel Server.

1. Press Assign and Select to enter assignment mode.

2. Press the button type you wish to assign (Dest, Src, Level, or Salvo).

3. Use the Up and Down buttons to choose the desired item.

Encore — Control Panels Operation Manual 83

Section 7 — JEP-100 Panel

4. With the item displayed in the Preset window, press the physical button on the front panel to which you wish to assign that item.

5. Press Assign and Select to exit assign mode.

Front Panel Menu ProgrammingSome features can be configured on the JEP-100 from the front panel (pro-vided the Panel Server Self Config Lock flag is turned off):

• Destination Ganging - Allows simultaneous selection of multiple Des-tination for control.

• Alias Names - Displays Alias names in the windows.

• Brightness - Adjusts the intensity of the Display window text.

• ID - Reports the IP address and name of the panel.

• Sticky Levels - Retains the last selected Levels for breakaway Takes.

To access these features, press the Menu button, then use the Up and Down buttons to scroll through the list of options.

For features simply turned on or off, press the Take button to toggle the state.

Note The window reports the potential state, not the current state. For example, DstGng-N indicates Destination Ganging is ON. Pressing the Take button will change the indicator to DstGng-Y and turn OFF Destination Ganging.

84 Encore — Control Panels Operation Manual

Section 8Panel Operation Variations

IntroductionThe previous sections described basic operating procedures for the factory default configurations of various Encore system control panels. Control panels at most facilities are probably configured with different function-ality. This section lists some of the more important configuration variations available and briefly describes how they affect control panel operation.

For a complete listing of all the panel configuration parameters, refer to the separate Encore Configuration Manual.

Note If you have questions about the operation of a specific Encore control panel at your facility, contact the on-site engineer responsible for configuring and maintaining your Encore system.

Button Functions and SelectionsDifferent functions can be assigned to programmable panel buttons, including Source Selection, Destination Selection, Level Selection, Protect/Lock, Salvo, Previous, Next, and others.

If a control panel button is assigned a selection function, the specific item (a particular Source, Destination, Level, or Salvo) is configured to be selected by pressing that button.

Exclusion SetsSets of items (Area, Destination, Level, Salvo) can be programmed to be unavailable for control by a particular control panel. In larger facilities, lim-iting the control of some items (on-air Destinations, for example) to only some panels at selected locations can prevent important signals from being changed accidentally by some distant control panel.

Encore — Control Panels Operation Manual 85

Section 8 — Panel Operation Variations

Keypad SetsAlternative keypad sets can be created that change, for example, which pre-fixes and suffixes are entered for item names. Keypad sets can be shared with multiple panels. Typically the same keypads sets are used throughout a facility so the various panels operate the same, but this is not required.

Page SetsPanels with multiple displays support page sets, which group items together so they can be called up simultaneously. Page sets exist for Desti-nations and Salvos.

Dynamic Audio Attribute ControlAudio attributes on Concerto audio routers can now be dynamically con-trolled using Encore system Control Panels, or from an RCL Client (for example, an automation system). The audio attributes are: Stereo (Normal), Left Only, Right Only, Swap, Sum, Invert Left, Invert Right, and Mute. Five attributes are mutually exclusive and three are independent (Figure 51).

Figure 51. Dynamic Audio Attributes

CH1 CH1

CH2 CH2

Stereo (Default Normal)

Left Channel

Right Channel

CH1

CH2

Left Only

Right

Left CH1

CH2Left

CH1

CH2

Right Only

RightLeft CH1

CH2Right

CH1

CH2CH2

CH1

Swap

Right

RightLeft

Left

CH1

CH2

Sum

Right

Left CH1

CH2Left & Right

Left & Right

8153

_50r

0

Left Invert

CH1 CH1

CH2 CH2Right Channel

Right Invert

CHA CH1

CHB CH2

Left Channel

Mutally Exclusive Attributes (5)

Independent Attributes (3)

CH2

CH1

Mute

Right

Left

Any one of the five mutually exclusive attributes can be enabled at a time. One or more of the three independent attributes can be activated in combi-

86 Encore — Control Panels Operation Manual

Button Functions and Selections

nation with any other attributes. For example, you can Swap the channels and also invert the Left channel. Incoming (upstream) signals are inverted, so in this example the Left channel is inverted and that inverted signal is passed to the right channel (Figure 52).

Figure 52. Applying Multiple Dynamic Audio Attributes

CH1

CH2CH2

CH1

Swap

Right

RightLeft

Left

8153

_51r

0

Left Invert

CH1 CH1

CH2 CH2Right Channel

Mutally Exclusive Attributes (downstream)Independent Attribute (upstream)

Applying Mute silences both channels. If a Mute is applied in conjunction with any other attributes and the Mute is then released, the audio attributes previously set remain in force and are restored when Mute ends.

Dynamic audio attributes control are supported by the following matrices:

• Concerto (Analog and AES/EBU Digital Audio).

Note On Concerto Analog Audio matrices, matrix outputs must be wired as left-right channel pairs.

Multiple bus panels (PMB, EDP, MB8, MB4) do not support dynamic audio attribute control.

Dynamic Audio Configuration

Control Panels are configured for dynamic audio control by assigning these functions to buttons, using the standard Encore configuration procedures. Refer to the separate Encore Configuration Manual for details.

Dynamic Audio Operation

Once audio functions have been assigned to Control Panel buttons, they will behave as follows:

• Multiple destination Control Panels must be in Source mode to access the dynamic audio features.

• Pressing an unilluminated Audio Left Only, Audio Right Only, Audio Swap, or Audio Sum button lights that button, activates that audio attribute, and deactivates any of the other attributes in this group (they are mutually exclusive). Pressing one of these buttons when it is illuminated deacti-vates that attribute and restores the normal Stereo audio attribute.

Encore — Control Panels Operation Manual 87

Section 8 — Panel Operation Variations

• If an Audio Stereo button is configured on the Control Panel, it illumi-nates when no other mutually exclusive attribute is enabled. Pressing this button when it is not illuminated selects normal Stereo operation, disabling any other mutually exclusive audio attribute.

• The independent audio attributes buttons (Audio Invert Left, Audio Invert Right, Audio Mute) are enabled and disabled individually by pressing those buttons. These buttons illuminate when that attribute is active and go off when inactive.

• Salvos can be created to control dynamic audio attributes (on a salvo element by salvo element basis).

Attributes and FlagsSome control panel behavior not related to a particular button function or selection can be changed by setting control panel attributes and/or flags during panel configuration. Some of the control panel attributes and flags that significantly affect panel operation are described below.

General Settings

Auto Tally

Sets the Source Tally to the first active and enabled Level of the active Des-tination.

Note Turning Auto Tally ON disables Tally Level button functionality.

Auto Level Latching

When doing breakaway takes on panels without dedicated Level buttons, the selected breakaway Levels can be persistent (remain in force for subse-quent takes), or can be cleared automatically (revert to all Levels after per-forming a take).

• When the Auto Level Latching flag is on, the current enabled/disabled Levels state is applied to subsequent Takes for that active Destination. Selecting a different Destination cancels the breakaway.

• When the Auto Level Latching flag is off, all Levels of the current active Destination are enabled after a take or change of active Destination, regardless of the previous Level enable states(s).

88 Encore — Control Panels Operation Manual

Attributes and Flags

Default Tally Level

Specifies the Level that will Tally by default in panel displays if a Level has not been specifically selected for Tally on that panel.

Display Alias Names

Alternative, or Alias, names can be configured for Sources and Destina-tions. Setting this flag on will display alias names on control panels with displays.

Dst Change Lock

When on, Dst Change Lock disables the panel’s ability to change Destina-tions.

Level Change Lock

When on, Level Change Lock disables the panel’s ability to select indi-vidual Levels to perform a breakaway Take.

Protect and Lock SettingsBecause the Encore control system uses multiple points of control (various control panels, Encore OUI, automation interfaces) some flags affect how different control panels interact. Specifically, the Protect and Lock features determine how changing Sources to Destinations can be restricted. This is useful if, for example, a VTR operator needs to ensure that the incoming Source remains present for the duration of a recording, and is not switched to another Source by some other panel in the facility.

The Protect, Hard Lock, and Soft Lock flags are mutually exclusive. For example, setting a Hard Lock on a panel automatically clears a Protect or Soft Lock flag for that panel, if set.

Protect

The Protect flag allows a control panel to set Protects on Destinations. Once a Protect is set, other panels cannot change the Source to that Destination, but the panel that had set the Protect is able to change that Destination’s Source, with some exceptions. Other panels with Lock/Protect Override or Force Unlock/Protect flags set can change Sources on Protected Destina-tions.

Encore — Control Panels Operation Manual 89

Section 8 — Panel Operation Variations

Hard Lock

The Hard Lock flag acts like Protect, except even the panel that set the Lock also cannot change a locked Destination’s Source. That panel must first remove the lock before the Destination can be switched. Other panels with Lock/Protect Override or Force Unlock/Protect flags set can change Sources on Locked Destinations.

Soft Lock

The Soft Lock flag acts like Protect, except any other panel can also remove the Protect from a Destination.

Lock/Protect Override

Lock/Protect Override allows a panel to temporarily remove a Lock or Protect from a Destination, and change the Source to that Destination. The Lock or Protect remains in force after the change to the new Source.

Force Unlock/Protect

Force Unlock/Protect allows a panel to remove a Lock or Protect from a Destination.

Salvo Editor Lock/Protect

The separate Salvo Editor application supports creating Salvos with Lock-Protect/Unlock-Unprotect capabilities. Executing a Salvo with this setting ON can, for example, lock one or more Destinations. A Salvo can also created to unlock one or more Destinations, perform Takes, and then either leave the Destinations unlocked or restore the Lock. Some limitations exist, including the inability to override some Protects, depending on the device issuing the Salvo. See the separate Salvo Editor Instruction Manual for spe-cific information.

Control Panel GroupingSome control panels can be configured to act together as a single larger control panel. Typically a 48B panel is grouped with a panel that has control functions and displays, and the 48B panel is configured with additional Sources and/or Destinations. See the separate Encore Configuration Manual for specific information.

90 Encore — Control Panels Operation Manual

Attributes and Flags

Joystick OverrideSome control panels have GPI connectors that can be used for Joystick over-ride. Joystick override permits switching the displayed video to another Source, and then either returning to the previously selected Source or keeping the Override Source displayed. This feature is typically used for camera matching.

Joystick Override Configuration

Joystick override has two operating modes, latching and non-latching. The mode is selected by assigning either the Source or Source (non-latching) func-tion to the Joystick Source button.

The following control panels support Joystick override:

Table 1. Joystick Override Panel

Encore panels BPS, 48B

Kalypso panels KMD, KSD

SMS panels P48, P32

Note On grouped control panels only the master panel’s joystick override can be used.

See the separate Encore Configuration Manual and Encore Installation and Service Manual for information about setting up panels for Joystick over-ride.

Joystick Override Operation

Activating a non-latching Joystick override (typically done by pressing a button on a camera remote control unit) switches to that Source, and releasing the button restores the last Source. A latching override keeps the override Source displayed until another Source is selected.

If multiple non-latching overrides are active, releasing overrides steps back through previous overrides in the reverse order of their selection. The last selected override will be restored when another override is released. For example, suppose Source A is selected for a non-latching override and held, then Source B is selected for override and held, and then Source C is selected for override and held. In this case, releasing Source C override restores Source B override, and then releasing Source B override restores Source A override.

Encore — Control Panels Operation Manual 91

Section 8 — Panel Operation Variations

92 Encore — Control Panels Operation Manual

Index

Numerics48B panel 47

Auto Tally feature 48breakaway Take procedure 48default button assignments 47features 47general description 47Protect procedure 49Salvo procedure 49Take procedure 48Tally Level procedure 49

7500 control by Encore 14

AAcappella control by Encore 14Acappella local panel 76Acappella panel

buttons not present 77control panel templates 77default button assignments 77general description 75local 76operation 78software 75types 75

all level Take 21illustration 21

AllSvos 27Apex

control by Encore 14Area

definition 18Auto Level Latching flag 88Auto Tally feature 48Auto Tally flag 88

BBPS panel 44

breakaway Take procedure 45

default button assignments 44features 44general description 44Protect procedure 45Salvo procedure 46self configuration 46single destination default 45Take procedure 45

breakawaydefinition 18

breakaway Take 21illustration 21

breakaway Take procedureEncore 48B panel 48Encore BPS panel 45Encore PMB panel 36Encore XY panel 42JEP-100 panel 82SMS7000 P32 panel 60SMS7000 P3XS panel 68SMS7000 UCP panel 57

button assignmentJEP-100 panel 83

button selectionsavailable for panel buttons 85

Cchannel definition 18Chop

configuration 28definition 18general description 27limitations 29operation 28protect 29

Chop Lock 28Chop Switch Rate 28CLNT panel (Encore) 52

configuration 52Destination assignment 53Destination identification 53

Encore — Control Panels Operation Manual 93

Index

operation 52Source assignment 53Source identification 53Take procedure 53

CLNT panel (SMS7000) 59Concerto control by Encore 14configuration

control panel 25configuration PC

general description 17control panel

Acappella features 75Acappella types 24, 75communications interfaces 25configuration 25Encore 48B 47Encore 48B features 47Encore BPS features 44Encore Client 52Encore defaults 25Encore features 33Encore PMB 34Encore types 23Encore UCP 50Encore XY 40Encore XY features 40Encore XY general description 40general description 16grouping 90hardware types 23JEP-100 features 79Kalypso KMD 72Kalypso KSD 74Kalypso remote aux types 24, 72operation with non-default settings 85SMS7000 CLNT 59SMS7000 EDP 64SMS7000 MB4 62SMS7000 MB8 61SMS7000 P32 59SMS7000 P48 65SMS7000 PXY panel set 66SMS7000 SCP panel 68SMS7000 types 23SMS7000 UCP 56software 24software update 25

control panel buttonsavailable functions 85

available selections 85crosspoint

definition 18

Ddatabase

general description 17default button assignments

Acappella panel 77Encore 48B panel 47Encore BPS panel 44Encore PMB panel 35Encore UCP panel 50Encore XY panel 40JEP-100 panel 80Kalypso KMD panel 73Kalypso KSD panel 74SMS7000 EDP panel 65SMS7000 MB4 panel 63SMS7000 MB8 panel 61SMS7000 P32 panel 60SMS7000 P48 panel 65SMS7000 PXD panel 67SMS7000 PXS panel 67SMS7000 PXY panel set 66SMS7000 PXYE panel 67SMS7000 SCP panel 69SMS7000 UCP panel 56

DefaultTally Level flag 89Dest Ganging Option 1 30Dest Ganging Option 2 30Destination

definition 18general description 20

Destination assignmentEncore CLNT panel 53

Destination Ganging 30Breakaway Take 31configuration 30operation 30Protect 31

Destination identificationEncore CLNT panel 53

Destination name reportingEncore XY panel 41

Destination selectionJEP-100 panel 81

94 Encore — Control Panels Operation Manual

Index

Display Alias Names flag 89distributed control 17documentation online 4documentation set 11Dst Change Lock flag 89Dynamic Audio

configuration 87operation 87

Dynamic Audio Attribute Control 86Dynamic Page Set

configuration 39creation 39operation 39

EEDP panel 64

default button assignments 65general description 64operation 64

ENC UCP paneldefault button assignments 50operation 51

Encoredatabase 17distributed control 17documentation set 11general description 13system diagram 13

Encore 48B panelgeneral description 47

Encore BPS panel 44general description 44

Encore CLNT panel 52configuration 52Destination assignment 53Destination identification 53operation 52Source assignment procedure 53Source identification 53

Encore control panelPanel ID 33

Encore PMBfeatures 34general description 34

Encore System Controllerconnectors 15

general description 14multiple 15rear view 15

Encore system diagram 13Encore UCP panel 50

configuration as Server 52features 50general description 50

Encore XY panelstatus reporting 41

error messagespanel sign on 26

Ethernet 24exclusion set

definition 18types of 85

FFAQ database 4flag

Auto Level Latching 88Auto Tally 88Default Tally Level 89definition 18Display Alias Names 89Dst Change Lock 89Force Unlock/Protect 90Hard Lock 90Level Change Lock 89Lock/Protect Override 90Protect 89Soft Lock 90

Force Unlock/Protectflag 90

frequently asked questions 4Front

16x16 7616x8 768x1 76

functionsavailable for panel buttons 85

GGlobal Serial Channel (GSC) 24

general description 55

Encore — Control Panels Operation Manual 95

Index

Grass Valley web site 4grouping

control panel 90GSC (Global Serial Channel) 24GUI

Soft Panels 24

HHard Lock

flag 90hardware

controlled by Encore 14Hold button

MB4 panel 63Horizon control by Encore 14

JJEP-100 panel

breakaway Take procedure 82button assignment 83default button assignments 80Destination selection 81general description 80menu programming 84operation 81power supply 79Protect procedure 83Salvo procedure 83specifications 79Take procedure 82

Joystick override 91configuration 91latching 91non-latching 91operation 91

KKalypso KMD

panel operation 73Kalypso KSD

panel operation 74Kalypso remote aux panel

features 71general description 71

Panel ID 73software 71types 72

keypad setalternative 86

KMD control panel 72KMD panel

default button assignments 73operation 73

KSD control panel 74KSD panel

default button assignments 74operation 74

LLevel

definition 18general description 19

Level Change Lock flag 89licensing 24Load button

MB4 panel 64Lock

configuration 89relationship to Protect 89

Lock/Protectusing Salvos 90

Lock/Protect Overrideflag 90

Mmatrix

definition 18matrix crosspoints

general description 19MB4 panel 62

default button assignments 63general description 62Hold button 63Load button 64operation 63

MB8 panel 61default button assignments 61general description 61operation 62

96 Encore — Control Panels Operation Manual

Index

menu programmingJEP-100 panel 84

multi-level switchinggeneral description 21

NNetConfig

and SMS7000 panels 55

Oonline documentation 4

PP32 panel 59

breakaway Take procedure 60default button assignments 60features 59general description 59Protect procedure 61Take procedure 60

P48 panel 65default button assignments 65general description 65operation 65

page settypes of 86

Panel IDEncore control panel 33Kalypso remote aux panel 73

PMB panel 34breakaway Take procedure 36default button assignments 35features 34general description 34Protect procedure 38Salvo procedure 38Take procedure 35Tally Level procedure 37

presetdefinition 19

Protectand Quick Take mode 54configuration 89definition 19flag 89

general description 26relationship to Lock 89

Protect procedureEncore 48B panel 49Encore BPS panel 45Encore PMB panel 38Encore XY panel 43JEP-100 panel 83SMS7000 P32 panel 61SMS7000 PXS panel 68SMS7000 UCP panel 58

PXD paneldefault button assignments 67

PXS panelbreakaway Take procedure 68default button assignments 67Protect procedure 68Source/Level selection 67Take procedure 67

PXS panel groupTake procedure 68

PXY panel set 66configuration 66default button assignments 66features 66general description 66

PXYE paneldefault button assignments 67

QQuick Take mode 54

Rremote aux panel

features 71routing terminology 18

SSalvo

definition 19general description 27

Salvo Editor application 90Salvo Editor Lock/Protect 90Salvo procedure

Encore — Control Panels Operation Manual 97

Index

Encore 48B panel 49Encore BPS panel 46Encore PMB panel 38Encore XY panel 43JEP-100 panel 83SMS7000 UCP panel 58

SalvosAll Salvos 27

SCP panel 68default button assignments 69general description 68operation 69

self configurationEncore BPS panel 46

Sharergeneral description 17

Sharer PCgeneral descripion 18

Shiftconfiguration 29operation 29

Shift functionsControl Panel

Shift 29sign on error message 26SMS7000

Global Serial Channel 24SMS7000 control by Encore 14SMS7000 control panel

general description 55SMS7000 EDP

general description 64panel operation 64

SMS7000 MB4general description 62panel operation 63

SMS7000 MB8general description 61panel operation 62

SMS7000 P32features 59general description 59

SMS7000 P48general description 65panel operation 65

SMS7000 paneland NetConfig 55

software 55SMS7000 PXY panel set

configuration 66features 66general description 66

SMS7000 SCPpanel operation 69

SMS7000 SCP panelgeneral description 68

SMS7000 UCPfeatures 56general description 56

Soft Lockflag 90

Soft Panels 24general description 24GUI 24licensing 24

softwarecontrol panel 24control panel update 25

software download from web 4Source

definition 19general description 20

Source assignment procedureEncore CLNT panel 53

Source identificationEncore CLNT panel 53

Source name reportingEncore XY panel 41

status reportingEncore XY panel 41

System Controllergeneral description 14power supply module 15reset button 15

System Controller Frameslots 15

TTake

all level 21all level illustration 21breakaway 21breakaway iIlustration 21

98 Encore — Control Panels Operation Manual

Index

definition 19Take procedure

Encore 48B panel 48Encore BPS panel 45Encore CLNT panel 53Encore PMB panel 35Encore XY panel 41JEP-100 panel 82SMS7000 P32 panel 60SMS7000 PXS panel 67SMS7000 PXS panel group 68SMS7000 UCP panel 57

tallydefinition 19

Tally Level procedureEncore 48B panel 49Encore PMB panel 37

templatedefinition 19

terminology 18tie-line

definition 19general description 22

Trinixcontrol by Encore 14

UUCP panel (Encore) 50

configuration as Server 52default button assignments 50features 50general description 50operation 51

UCP panel (SM7000) 56breakaway Take procedure 57default button assignments 56features 56general description 56Protect procedure 58Salvo procedure 58Take procedure 57

Unlock/Unprotectusing Salvos 90

Vvirtual control panel 24

Wweb site documentation 4web site FAQ database 4web site Grass Valley 4web site software download 4

XXY panel 40

breakaway Take procedure 42default button assignments 40features 40general description 40Protect procedure 43Salvo procedure 43status reporting 41Take procedure 41

Encore — Control Panels Operation Manual 99

Index

100 Encore — Control Panels Operation Manual