Upload
achuthkumar
View
9
Download
0
Embed Size (px)
DESCRIPTION
gruner
Citation preview
Relay 733
Description
Polarized latching relay for 100 A
The relays are designed and manufactured in accord- ance to the Standards of IEC 61810, Part 1-00/VDE 0435, Part 201, which are also in accordance to the Low Voltage Directive (LVD).
The advantage of the polarized latching relays is the pulse driv en operation of 30 miliseconds. Therefore there is a low need of setting power and the coil heating can be neglected. Relay can be set by manual operation.
The relays are designed and manufactured in accordance to international standards of IEC 61810 part 1/VDE 0435 part 201 as well as they meet overload and short circuit requirements of IEC 62053/62054/62055(UC3).
1/2
Technical data
Coil data Rated voltage 6 – 48 VDC
Rated power 16 W
Operating power to set 10.25 W
Pulse to set 30 ms
Action time < 15 ms
Contact data Max. contact arrangement 3 a
Contact material AgSnO2
Max. switching power 25,000 VA
Max. switching voltage 440 VAC
Max. switching current 100 A
Mechanical life 106
Insulation Creepage and clearance distance coil – contact
8 mm
Test voltage coil – contact
4,000 V eff.
Test voltage contact – contact
–
Test voltage open contact
1,000 V eff.
Dielectric strength coil – contact
12 kV / 1.2 / 50 µs
General data Ambient temperature -40 … +85 °C
Weight 300 g
Conform to VDE, UL, CSA, SEV, SEMKO
2011
-12-
13 ·
Cop
yrig
ht b
y G
RUN
ER A
G ·
Subj
ect t
o te
chni
cal c
hang
es a
nd d
esig
n m
odific
atio
ns
Re lays
Technical Data
Relay 733
2/2
Technical drawing
01
45,645,6
41
45,33 45,33
45,3345,33
05,601
353252
5,32 8
8,65 8
02231
00,84
2
52,6 59,05
67,05
69,00
77,00
7,31
optional: manual override
20,50
240,50
4
30,00
ribbon cable or flying leeds tbd
switching positioncontacts
1/2(+)
2/3(+)
Terminal pinarrangement
1 2 3
1 2 3
The power terminals can be modified according to customer specification.
733 D
Identification
Example for ordering
Further versions
on request
Identification code
Type 733
Version D = see dim. drawing
Contact material R = AgSnO2
Contact arrangement 3A = 3 normally open
Terminal-grid B
Winding No. see coil table
733 R BD - -3A 9R0
Standard windings
Contact position
Terminal-grid B 2/3 (+) 1/2 (+)
The relay can also be used with a single
winding (lower operating power to set) if
the middle pin of coil is not used.
Standard winding No.
Nominal coil voltage
Operating voltage of the coil
Coil resistance Tolerance
Double winding (VDC) U1 – U2 (VDC) (Ohm) (± %)
2R2 6 4.8 – 7.8 2 x 2.2 10
9R0 12 9.6 – 15.6 2 x 9 10
035 24 19.2 – 31.2 2 x 35 10
140 48 38.4 – 62.4 2 x 140 10
Relays >> Technica l Data
GRUNER AG D-78564 Wehingen · Germany
Phone +49 7426 948-0 · Fax +49 7426 948-200 · www.gruner.de · [email protected]