9
Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 1 Description how to download the firmware and parameters to the Breuer inverter (Ecowin version 1.0.1.13) Date : 21.04.06 Update : 03.08.06 1. step: Connect the PC with the inverter via the interface cable (1 to 1 Refu extension cable). 2. step: Start software „eco Win”. If the communication between the PC and the converter could be established, the program starts up and shows the online status (see picture 1, online status has been established here). picture 1

En How to Program Air Cooled Breuer Inverter 3-08-06

Embed Size (px)

Citation preview

Page 1: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 1

Description how to download the firmware and parameters to the Breuer

inverter

(Ecowin version 1.0.1.13)

Date : 21.04.06

Update : 03.08.06

1. step: Connect the PC with the inverter via the interface cable (1 to 1 Refu extension

cable).

2. step: Start software „eco Win”. If the communication between the PC and the converter

could be established, the program starts up and shows the online status (see picture

1, online status has been established here).

picture 1

Page 2: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 2

Programming of the firmware

3. step: Over “Extras” select, “Flash Hit” (see picture 2).

picture 2

4. step: A window will show up and ask for the password.

The password is: “0000”.Confirm with “OK” (see picture 3).

picture 3

5. step: Confirm the safety inquiry question with “Yes” (see picture 4).

Page 3: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 3

picture 4

6. step: Select “Open hexfile” (see picture 5).

picture 5

7 step: Select the parameter set to be transferred with “Open” (see picture 6).

Page 4: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 4

picture 6

8. step: The firmware will be transferred automaticly (see picture 7 ).

Without a message the program “FLASHHit” ends after the transmission.

picture 7

Page 5: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 5

Programming of the parameters

9. step: Establish the communication between the PC and the inverter.

(Select „Online“, see picture 8 ).

picture 8

Page 6: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 6

10. step: Under the menu “File / Parameter set / Transfer / select Parameter

file → Converter” (see picture 9).

picture 9

Page 7: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 7

11. step: Select parameter set and “Open” (see picture 10 ).

picture 10

12. step: Confirm the “parameter set inquiry question” with “Yes” (see picture 11).

picture 11

13. step: Confirm the “device-specific parameters inquiry question” with “Yes” (see

picture 12 ).

picture 12

Page 8: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 8

14. step: Confirm “device-specific parameters” with “OK” (see picture 13 ).

picture 13

15. step: Parameters get transferred (see bar in picture 14).

picture 14

Page 9: En How to Program Air Cooled Breuer Inverter 3-08-06

Erstellt von Johannes Weberbauer 03.08.2006 ©J. Weberbauer 9

16. step: Confirm information window with “OK” and reset the converter (switch off- and

on). The transmission of the parameters is finished. (see picture 15).

picture 15