EN 2 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P200YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 22.40 kW
Seasonal space
cooling energy
efficiency
ηs,c 309 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC (dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given outdoor temperatures Tj
Tj = +35 ºC Pdc 22.40 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 5.05 %
Tj = + 30 ºC Pdc 16.51 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 6.11 %
Tj = + 25 ºC Pdc 10.61 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 11.11 %
Tj = + 20 ºC Pdc 10.15 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 16.21 %
Degradation co-efficient air
conditioners** Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater mode PCK 0.044 kW
Thermostat-off mode PTO 0.089 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 10200 m³/h
Sound power level,
outdoor LWA 76.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 3 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P200YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of heat pump: [select which: air]
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 25.00 kW
Seasonal space
heating energy
efficiency
ηs,h 174 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 21.09 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.50 %
Tj = + 2 ºC Pdh 13.45 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.96 %
Tj = + 7 ºC Pdh 8.65 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 7.22 %
Tj = + 12 ºC Pdh 5.64 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 10.07 %
Tj = bivalent
temperature Pdh 22.12 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.61 %
Tj = operation limit Pdh 15.13 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
1.99 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -7.0 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.089 kW Type of energy input
Crankcase heater mode PCK 0.044 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 10200 m³/h
Sound power level, indoor / outdoor
measured
LWA 78.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 4 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P250YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 28.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 316 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC (dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given outdoor temperatures Tj
Tj = +35 ºC Pdc 28.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.69 %
Tj = + 30 ºC Pdc 20.63 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.84 %
Tj = + 25 ºC Pdc 13.26 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 10.90 %
Tj = + 20 ºC Pdc 8.93 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 17.30 %
Degradation co-
efficient air
conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater mode PCK 0.044 kW
Thermostat-off mode PTO 0.089 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 11100 m³/h
Sound power level,
outdoor LWA 78.5 dB
if engine driven: Emissions of nitrogen
oxides
NOx -
mg/kWh fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 5 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P250YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 31.50 kW
Seasonal space
heating energy
efficiency
ηs,h 172 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 23.01 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.69 %
Tj = + 2 ºC Pdh 16.96 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.87 %
Tj = + 7 ºC Pdh 10.90 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.96 %
Tj = + 12 ºC Pdh 5.87 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 11.55 %
Tj = bivalent
temperature Pdh 25.71 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.95 %
Tj = operation limit Pdh 15.35 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.00 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -5.2 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.089 kW Type of energy input
Crankcase heater mode PCK 0.044 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 11100 m³/h
Sound power level, indoor / outdoor
measured
LWA 80.0 dB For water-/brine-to-
air heat pumps: Rated brine or water flow
rate, outdoor heat
exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 6 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P300YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×6units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 33.50 kW
Seasonal space
cooling energy
efficiency
ηs,c 297 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 33.50 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.44 %
Tj = + 30 ºC Pdc 24.68 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.46 %
Tj = + 25 ºC Pdc 15.87 kW Tj = + 25 ºC EERd or GUEc,bin/AEFc,bin
9.35 %
Tj = + 20 ºC Pdc 11.25 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 16.84 %
Degradation co-
efficient air
conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater mode PCK 0.043 kW
Thermostat-off mode PTO 0.090 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 12000 m³/h
Sound power level,
outdoor LWA 80.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq
(100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 7 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P300YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×6units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 37.50 kW
Seasonal space
heating energy
efficiency
ηs,h 167 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 29.42 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.58 %
Tj = + 2 ºC Pdh 20.19 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.72 %
Tj = + 7 ºC Pdh 12.98 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.89 %
Tj = + 12 ºC Pdh 7.45 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 10.68 %
Tj = bivalent
temperature Pdh 31.80 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.69 %
Tj = operation limit Pdh 19.93 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
1.87 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -6.1 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.0 kW
Thermostat-off mode PTO 0.090 kW Type of energy input
Crankcase heater mode PCK 0.043 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 14400 m³/h
Sound power level, indoor / outdoor
measured
LWA 86.5 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 8 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P350YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×2units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 40.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 298 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 40.00 kW Tj = +35 ºC EERd or GUEc,bin/AEFc,bin
3.98 %
Tj = + 30 ºC Pdc 29.47 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.94 %
Tj = + 25 ºC Pdc 18.95 kW Tj = + 25 ºC EERd or GUEc,bin/AEFc,bin
9.66 %
Tj = + 20 ºC Pdc 11.34 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 13.39 %
Degradation co-efficient air
conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater mode PCK 0.051 kW
Thermostat-off mode PTO 0.081 kW Standby mode PSB 0.076 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air conditioner: Nominal
air flow rate, outdoor
measured
- 15000 m³/h
Sound power level,
outdoor LWA 81.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 9 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P350YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×2units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 45.00 kW
Seasonal space
heating energy
efficiency
ηs,h 155 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 31.14 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.46 %
Tj = + 2 ºC Pdh 24.23 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.48 %
Tj = + 7 ºC Pdh 15.58 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.30 %
Tj = + 12 ºC Pdh 8.05 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 8.87 %
Tj = bivalent
temperature Pdh 35.11 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.96 %
Tj = operation limit Pdh 23.98 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.37 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -4.3 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.081 kW Type of energy input
Crankcase heater mode PCK 0.051 kW Standby mode PSB 0.076 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 15000 m³/h
Sound power level, indoor / outdoor
measured
LWA 83.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 10 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P400YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×5units , PEFY-P50VMHS2-E×1unit
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 45.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 283 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 45.00 kW Tj = +35 ºC EERd or GUEc,bin/AEFc,bin
3.88 %
Tj = + 30 ºC Pdc 33.16 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.34 %
Tj = + 25 ºC Pdc 21.32 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 8.47 %
Tj = + 20 ºC Pdc 12.41 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 14.79 %
Degradation co-efficient air
conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater mode PCK 0.054 kW
Thermostat-off mode PTO 0.078 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 16200 m³/h
Sound power level,
outdoor LWA 83.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 11 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P400YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×5units , PEFY-P50VMHS2-E×1unit
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 50.00 kW
Seasonal space
heating energy
efficiency
ηs,h 147 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 35.14 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.65 %
Tj = + 2 ºC Pdh 26.92 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.25 %
Tj = + 7 ºC Pdh 17.31 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 5.98 %
Tj = + 12 ºC Pdh 9.27 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 7.70 %
Tj = bivalent
temperature Pdh 38.54 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.97 %
Tj = operation limit Pdh 24.28 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.15 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -4.0 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.078 kW Type of energy input
Crankcase heater mode PCK 0.054 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 18900 m³/h
Sound power level, indoor / outdoor
measured
LWA 88.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 12 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P450YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 50.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 288 %
Declared cooling capacity for part load at given outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 50.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.04 %
Tj = + 30 ºC Pdc 36.84 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.32 %
Tj = + 25 ºC Pdc 23.68 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 8.58 %
Tj = + 20 ºC Pdc 16.33 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 15.50 %
Degradation co-
efficient air
conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater mode PCK 0.054 kW
Thermostat-off mode PTO 0.084 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal air flow rate, outdoor
measured
- 16200 m³/h
Sound power level,
outdoor LWA 83.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25. Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 13 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P450YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 56.00 kW
Seasonal space
heating energy
efficiency
ηs,h 143 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 35.68 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.67 %
Tj = + 2 ºC Pdh 30.15 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.13 %
Tj = + 7 ºC Pdh 19.38 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 5.64 %
Tj = + 12 ºC Pdh 8.63 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 6.73 %
Tj = bivalent
temperature Pdh 41.55 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 3.22 %
Tj = operation limit Pdh 24.52 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.22 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -3.3 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.084 kW Type of energy input
Crankcase heater mode PCK 0.054 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 18900 m³/h
Sound power level, indoor / outdoor
measured
LWA 89.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 14 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P500YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×8units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 56.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 277 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 56.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.40 %
Tj = + 30 ºC Pdc 41.26 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 4.42 %
Tj = + 25 ºC Pdc 26.53 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 8.29 %
Tj = + 20 ºC Pdc 17.46 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 16.32 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.047 kW
Thermostat-off mode PTO 0.091 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 17700 m³/h
Sound power level,
outdoor LWA 82.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 15 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P500YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×8units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 63.00 kW
Seasonal space
heating energy
efficiency
ηs,h 144 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 39.42 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.47 %
Tj = + 2 ºC Pdh 33.92 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.21 %
Tj = + 7 ºC Pdh 21.81 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 5.89 %
Tj = + 12 ºC Pdh 10.45 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 7.70 %
Tj = bivalent
temperature Pdh 45.62 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 3.08 %
Tj = operation limit Pdh 27.60 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.26 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -2.8 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.091 kW Type of energy input
Crankcase heater mode PCK 0.047 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 17700 m³/h
Sound power level, indoor / outdoor
measured
LWA 84.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 16 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-P550YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×8units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 63.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 265 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 63.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 3.93 %
Tj = + 30 ºC Pdc 46.42 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 4.12 %
Tj = + 25 ºC Pdc 29.84 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 7.95 %
Tj = + 20 ºC Pdc 17.34 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 16.00 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.047 kW
Thermostat-off mode PTO 0.091 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 19500 m³/h
Sound power level,
outdoor LWA 83.5 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 17 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-P550YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×8units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 69.00 kW
Seasonal space
heating energy
efficiency
ηs,h 138 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 42.25 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.51 %
Tj = + 2 ºC Pdh 37.15 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.00 %
Tj = + 7 ºC Pdh 23.88 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 5.82 %
Tj = + 12 ºC Pdh 10.62 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 8.58 %
Tj = bivalent
temperature Pdh 48.77 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.95 %
Tj = operation limit Pdh 29.53 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.12 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -2.4 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.091 kW Type of energy input
Crankcase heater mode PCK 0.047 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 24600 m³/h
Sound power level, indoor / outdoor
measured
LWA 89.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 18 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP200YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 22.40 kW
Seasonal space
cooling energy
efficiency
ηs,c 335 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 22.40 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 5.29 %
Tj = + 30 ºC Pdc 16.51 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 7.99 %
Tj = + 25 ºC Pdc 10.61 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 12.28 %
Tj = + 20 ºC Pdc 7.40 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 13.56 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.044 kW
Thermostat-off mode PTO 0.089 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 10200 m³/h
Sound power level,
outdoor LWA 76.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 19 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP200YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of heat pump: [select which: air]
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 25.00 kW
Seasonal space
heating energy
efficiency
ηs,h 184 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 22.20 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.88 %
Tj = + 2 ºC Pdh 13.45 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 4.27 %
Tj = + 7 ºC Pdh 8.65 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 7.24 %
Tj = + 12 ºC Pdh 5.40 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 7.93 %
Tj = bivalent
temperature Pdh 23.20 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.72 %
Tj = operation limit Pdh 14.90 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
1.71 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -8.1 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.089 kW Type of energy input
Crankcase heater mode PCK 0.044 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 10200 m³/h
Sound power level, indoor / outdoor
measured
LWA 78.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 20 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP250YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 28.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 344 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 28.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.98 %
Tj = + 30 ºC Pdc 20.63 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 8.01 %
Tj = + 25 ºC Pdc 13.26 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 12.31 %
Tj = + 20 ºC Pdc 10.00 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 13.60 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.044 kW
Thermostat-off mode PTO 0.089 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 11100 m³/h
Sound power level,
outdoor LWA 78.5 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 21 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP250YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 31.50 kW
Seasonal space
heating energy
efficiency
ηs,h 177 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 22.20 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.94 %
Tj = + 2 ºC Pdh 16.96 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 4.36 %
Tj = + 7 ºC Pdh 10.90 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 7.38 %
Tj = + 12 ºC Pdh 5.40 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 8.08 %
Tj = bivalent
temperature Pdh 25.25 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.72 %
Tj = operation limit Pdh 14.90 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
1.71 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -4.8 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.089 kW Type of energy input
Crankcase heater mode PCK 0.044 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 11100 m³/h
Sound power level, indoor / outdoor
measured
LWA 80.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 22 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP300YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×6units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 33.50 kW
Seasonal space
cooling energy
efficiency
ηs,c 323 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 33.50 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.53 %
Tj = + 30 ºC Pdc 24.68 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 6.26 %
Tj = + 25 ºC Pdc 15.87 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 10.63 %
Tj = + 20 ºC Pdc 11.97 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 17.10 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.043 kW
Thermostat-off mode PTO 0.090 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 12000 m³/h
Sound power level,
outdoor LWA 80.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 23 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP300YNW-A (-BS) Indoor : PEFY-P50VMHS2-E×6units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 37.50 kW
Seasonal space
heating energy
efficiency
ηs,h 166 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 27.52 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.23 %
Tj = + 2 ºC Pdh 20.19 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.97 %
Tj = + 7 ºC Pdh 12.98 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.15 %
Tj = + 12 ºC Pdh 7.29 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 9.12 %
Tj = bivalent
temperature Pdh 31.45 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.85 %
Tj = operation limit Pdh 11.93 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
1.94 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -5.8 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.090 kW Type of energy input
Crankcase heater mode PCK 0.043 kW Standby mode PSB 0.084 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 14400 m³/h
Sound power level, indoor / outdoor
measured
LWA 86.5 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 24 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP350YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×2units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 40.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 333 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 40.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.54 %
Tj = + 30 ºC Pdc 29.47 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 6.31 %
Tj = + 25 ºC Pdc 18.95 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 11.27 %
Tj = + 20 ºC Pdc 13.82 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 15.91 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.051 kW
Thermostat-off mode PTO 0.081 kW Standby mode PSB 0.076 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 15000 m³/h
Sound power level,
outdoor LWA 81.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 25 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP350YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×2units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 45.00 kW
Seasonal space
heating energy
efficiency
ηs,h 161 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 32.24 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.46 %
Tj = + 2 ºC Pdh 24.23 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.49 %
Tj = + 7 ºC Pdh 15.58 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.50 %
Tj = + 12 ºC Pdh 8.34 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 10.28 %
Tj = bivalent
temperature Pdh 35.96 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 3.12 %
Tj = operation limit Pdh 23.10 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.24 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -4.8 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.081 kW Type of energy input
Crankcase heater mode PCK 0.051 kW Standby mode PSB 0.076 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 15000 m³/h
Sound power level, indoor / outdoor
measured
LWA 83.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 26 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP400YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×5units , PEFY-P50VMHS2-E×1unit
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 45.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 311 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 45.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 3.97 %
Tj = + 30 ºC Pdc 33.16 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 6.12 %
Tj = + 25 ºC Pdc 21.32 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 9.23 %
Tj = + 20 ºC Pdc 15.47 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 17.67 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.054 kW
Thermostat-off mode PTO 0.078 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 16200 m³/h
Sound power level,
outdoor LWA 83.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 27 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP400YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×5units , PEFY-P50VMHS2-E×1unit
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 50.00 kW
Seasonal space
heating energy
efficiency
ηs,h 159 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 37.26 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.82 %
Tj = + 2 ºC Pdh 26.92 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.60 %
Tj = + 7 ºC Pdh 17.31 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 5.94 %
Tj = + 12 ºC Pdh 8.27 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 7.10 %
Tj = bivalent
temperature Pdh 40.71 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 3.11 %
Tj = operation limit Pdh 24.87 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.21 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -5.2 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.078 kW Type of energy input
Crankcase heater mode PCK 0.054 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 18900 m³/h
Sound power level, indoor / outdoor
measured
LWA 88.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 28 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP450YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 50.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 307 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 50.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.66 %
Tj = + 30 ºC Pdc 36.84 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.76 %
Tj = + 25 ºC Pdc 23.68 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 9.00 %
Tj = + 20 ºC Pdc 15.81 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 16.07 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.054 kW
Thermostat-off mode PTO 0.084 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 16200 m³/h
Sound power level,
outdoor LWA 83.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 29 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP450YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×4units , PEFY-P50VMHS2-E×4units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 56.00 kW
Seasonal space
heating energy
efficiency
ηs,h 151 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 37.35 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.96 %
Tj = + 2 ºC Pdh 30.15 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.52 %
Tj = + 7 ºC Pdh 19.38 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.12 %
Tj = + 12 ºC Pdh 8.63 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 7.31 %
Tj = bivalent
temperature Pdh 41.12 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.95 %
Tj = operation limit Pdh 24.28 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.08 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -3.1 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.084 kW Type of energy input
Crankcase heater mode PCK 0.054 kW Standby mode PSB 0.073 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 18900 m³/h
Sound power level, indoor / outdoor
measured
LWA 89.0 dB For water-/brine-to-
air heat pumps: Rated brine or water
flow rate, outdoor
heat exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 30 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP500YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×8units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 56.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 301 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 56.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 4.41 %
Tj = + 30 ºC Pdc 41.26 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 5.12 %
Tj = + 25 ºC Pdc 26.53 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 9.02 %
Tj = + 20 ºC Pdc 18.30 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 17.52 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.047 kW
Thermostat-off mode PTO 0.091 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 17700 m³/h
Sound power level,
outdoor LWA 82.0 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 31 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP500YNW-A (-BS) Indoor : PEFY-P63VMHS2-E×8units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 63.00 kW
Seasonal space
heating energy
efficiency
ηs,h 148 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 39.57 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.47 %
Tj = + 2 ºC Pdh 33.92 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.23 %
Tj = + 7 ºC Pdh 21.81 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.11 %
Tj = + 12 ºC Pdh 10.93 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 10.04 %
Tj = bivalent
temperature Pdh 45.88 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 3.12 %
Tj = operation limit Pdh 27.00 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.25 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -2.9 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.091 kW Type of energy input
Crankcase heater mode PCK 0.047 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 17700 m³/h
Sound power level, indoor / outdoor
measured
LWA 84.0 dB For water-/brine-to-
air heat pumps: Rated brine or water flow
rate, outdoor heat
exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 32 EN
PRODUCT INFORMATION(1)
Model(s): Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP550YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×8units
Outdoor heat exchanger of air conditioner: [default: air]
Indoor heat exchanger of air conditioner: [default: air]
Type: compressor driven vapour compression or sorption process
if applicable: driver of compressor: [electric motor or internal combustion]
Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 63.00 kW
Seasonal space
cooling energy
efficiency
ηs,c 289 %
Declared cooling capacity for part load at given
outdoor temperatures Tj and indoor 27º/19ºC
(dry/wet bulb)
Declared energy efficiency ratio or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = +35 ºC Pdc 63.00 kW Tj = +35 ºC EERd or
GUEc,bin/AEFc,bin 3.94 %
Tj = + 30 ºC Pdc 46.42 kW Tj = + 30 ºC EERd or
GUEc,bin/AEFc,bin 4.82 %
Tj = + 25 ºC Pdc 29.84 kW Tj = + 25 ºC EERd or
GUEc,bin/AEFc,bin 8.87 %
Tj = + 20 ºC Pdc 19.31 kW Tj = + 20 ºC EERd or
GUEc,bin/AEFc,bin 16.28 %
Degradation co-
efficient air conditioners**
Cd 0.25 -
Power consumption in modes other than 'active
mode'
Off mode POFF 0.000 kW Crankcase heater
mode PCK 0.047 kW
Thermostat-off mode PTO 0.091 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air air
conditioner: Nominal
air flow rate, outdoor
measured
- 19500 m³/h
Sound power level,
outdoor LWA 83.5 dB
if engine driven:
Emissions of nitrogen
oxides
NOx -
mg/kWh
fuel input
GCV
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient air conditioners shall be 0.25.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on
the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281
EN 33 EN
PRODUCT INFORMATION(1)
Information to identify the model(s) to which the information relates :
Outdoor : PURY-EP550YNW-A (-BS) Indoor : PEFY-P71VMHS2-E×8units
Outdoor heat exchanger of heat pump: [select which: air
Indoor heat exchanger of heat pump: [select which: air]
Indication if the heater is equipped with a supplementary heater: no
Parameters shall be declared for the average heating season, parameters for the warmer and colder heating seasons
are optional.
Item Symbol Value Unit Item Symbol Value Unit
Rated heating capacity Prated,h 69.00 kW
Seasonal space
heating energy
efficiency
ηs,h 141 %
Declared heating capacity for part load at indoor
temperature 20 °C and outdoor temperature Tj
Declared coefficient of performance or gas utilization
efficiency / auxiliary energy factor for part load at given
outdoor temperatures Tj
Tj = - 7 ºC Pdh 41.19 kW Tj = - 7 ºC COPd or
GUEh,bin/AEFh,bin 2.51 %
Tj = + 2 ºC Pdh 37.15 kW Tj = + 2 ºC COPd or
GUEh,bin/AEFh,bin 3.03 %
Tj = + 7 ºC Pdh 23.88 kW Tj = + 7 ºC COPd or
GUEh,bin/AEFh,bin 6.24 %
Tj = + 12 ºC Pdh 11.00 kW Tj = + 12 ºC COPd or
GUEh,bin/AEFh,bin 11.14 %
Tj = bivalent
temperature Pdh 47.78 kW
Tj = bivalent
temperature
COPd or
GUEh,bin/AEFh,bin 2.95 %
Tj = operation limit Pdh 27.92 kW Tj = operation limit COPd or GUEh,bin/AEFh,bin
2.06 %
For air-to-water heat
pumps: Tj = - 15 ºC (if
TOL < - 20 ºC)
Pdh - kW
For water-to-air heat
pumps: Tj = - 15 ºC
(if TOL < -20 ºC)
COPd or
GUEh,bin/AEFh,bin - %
Bivalent temperature Tbiv -2.0 ºC
For water-to-air heat
pumps: Operation
limit temperature
Tol - ºC
Degradation co-
efficient heat pumps** Cdh 0.25 -
Power consumption in modes other than 'active
mode' Supplementary heater
Off mode POFF 0.000 kW Electric back-up
heating capacity * elbu 0.000 kW
Thermostat-off mode PTO 0.091 kW Type of energy input
Crankcase heater mode PCK 0.047 kW Standby mode PSB 0.080 kW
Other items
Capacity control fixed/staged/variable
For air-to-air heat
pumps: Nominal air
flow rate, outdoor
measured
- 24600 m³/h
Sound power level, indoor / outdoor
measured
LWA 89.0 dB For water-/brine-to-
air heat pumps: Rated brine or water flow
rate, outdoor heat
exchanger
- - m³/h
Emissions of nitrogen
oxides (if applicable) NOx - mg/kWh
GWP of the refrigerant 2088 kg CO2 eq (100 years)
Contact details Name and address of the manufacturer or of its authorised representative.
** If Cd is not determined by measurement then the default degradation coefficient of heat pumps shall be 0.25.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the
manufacturer or importer.
(1) This information is based on COMMISSION REGULATION(EU)2016/2281