ऺेत्रीय कायााऱय / R e g i o n a l o f f i c e 46, ई.सी.रोड, आई.डी.ए.टावर / 46,E.C.Road,IDA Tower, 1
st फ्ऱोर, निकट द्वारका स्टोर / 1
st Floor, Near Dwarka Store,
देहरादिू / Dehradun-248001 उत्तराखंड / Uttrakhand ।
दरूभाष/Telephone:0135-2716903,04,05
फैक्सष/Fax: 0135-2716901
( सुरक्षा कक्ष / SECURITY CELL )
Ref. No.10/RODDN/SEC/2018/HS/S-02 ददिांक / Date: 06.01.2018
Empanelment of Venders for Supply/Installation& AMC of Security & Fire
Safety Gadget for branches under RO:Dehradun for 2018-2019 and 2019-2020.
1. Applications are invited from reputed agencies for empanelment of Security Vendors for
Supply/Installation / AMC of Security & Fire Related Equipments/Gadgets of various
categories for branches/ATMs of our Bank in under RO Dehradun. The jurisdiction of RO
Dehradun includes all districts of Uttarakhand state and 04 districts of Uttar Pradesh (Bijnor,
Muzaffarnagar, Shamli, Saharanpur) .
NO
DESCRIPTION OF STORES / SERVICES
I. Empanelment of Security Vendors for Supply/Installation / AMC of Security & Fire safety Related
Equipments/Gadgets for Branches/ ATMs/ Administrative Offices under RO: Dehradun). The
details of Category / Item or System / Equipments are as under.
CATEGORY – SUPPLY&INSTALLATION OF SECURITY GADGETS
a. SECURITY ALARM SYSTEM
b. DVR BASED CCTV SYSTEM
c. STAND ALONE BURGLAR ALARM SYSTEM FOR ATMS. d. ACCESS CONTROL SYSTEM
e. AUTOMATIC FIRE DETECTION AND ALARM SYSTEM
CATEGORY - AMC
f. AMC OF ABOVE ITEMS (a to e)
CATEGORY - FIRE EXTINGUISHERS
g. SUPPLY / REFILLING OF FIRE EXTINGUISHERS
i. Modular Fire Extinguishers
ii . Portable Fire Extinguishers
2
II AIM OF EMPANELMENT:
To create and have a pool of readily available Security Vendors capable of supplying the required
system, equipment / components, or services of the laid down specifications, at competitive rate
without loss of time and are also able to provide the after sales service for at least 5-8 years to
ensure all time serviceability thereby prolonging the life of the security equipment.
II. a Empanelment will be for two separate groups
i. Empanelment for Supply / AMC of Security Equipments: -Services specified in items (a) to (e)
of Para, I i.e
CATEGORY – SUPPLY&INSTALLATION OF SECURITY GADGETS
a. SECURITY ALARM SYSTEM
b. DVR BASED CCTV SYSTEM
c. STAND ALONE BURGLAR ALARM SYSTEM FOR ATMS.
d. ACCESS CONTROL SYSTEM
e. AUTOMATIC FIRE DETECTION AND ALARM SYSTEM
CATEGORY - AMC
f. AMC OF ABOVE ITEMS (a to e)
ii. Empanelment for Supply & Installation of Fire Related Equipments/Gadgets (FEs):- Services
specified in item (g) of Para I, i.e
CATEGORY - FIRE EXTINGUISHERS
g. SUPPLY / REFILLING OF FIRE EXTINGUISHERS
i.Modular Fire Extinguishers
ii.Portable Fire Extinguishers
iii. Bids/Offers shall be submitted as per above classification / grouping. i.e The bidder may submit
the Bid for
x. Empanelment for Supply / AMC of Security Eqpts: -Services specified in items (a) to (f) of
Para I
or
3
y. Empanelment for Supply & Installation of Fire Related Equipments/Gadgets (FEs):-
Services specified in item (g) of Para I
or
z. For both Empanelment as shown in x & y
iv. If bids are not submitted as per above classification / grouping, it will be considered as
incomplete bids and will be rejected.
v. Bids if submitted for individual item/items other than specified in above grouping shall not be
entertained.
2. Interested Venders /suppliers available/ operating in the area within the stipulated time
should send their information as follows :
a) Introductory letter as per APPENDIX-“A” along with documentary proof.
b) Documents as mentioned in PQC (Pre-Qualification Criteria) at Para IV duly attested
with sign and seal of authorized signatory.
3. Venders /suppliers should ensure that their Security gadgets are as per the Technical
specifications / Data mentioned in APPENDIX-“B”.
4. Our officer/s shall visit the premises /office / manufacturing facility of each firm/vender and
verify the documents forwarded with the originals held by firms / suppliers.
5. The firms /suppliers will be rated as per procedure existing in our Bank.
6. Venders / Suppliers who fulfill the laid down criteria shall be requested to give
demonstration of the equipment before the empanelment committee so as to ascertain
the suitability and its conformity with laid down Technical specifications. The
committee shall shortlist the suppliers accordingly.
7. Firms / Suppliers/Venders selected will be requested to submit the sealed quotations for each
equipment to submit their financial bids in sealed covers.
8. Financial bids submitted by the short listed firms shall be opened by the empowered
committee as per the laid down procedure to ascertain the market rates. The rates will also be
standardized at our end in order to ensure common minimum rates for each equipment /
accessories.
9. Efforts will be made to empanel minimum of 3-5 venders.
10. The details should reach our Office at above mentioned address latest by 24 January
2018 by 03.00 PM positively.
GENERAL TERMS & CONDITIONS
II. a. incomplete offers, offers not confirming fully to the requirements specified in this letter or with vague
4
replies will not be considered.
b. Any conditional bids/applications shall not be considered and will be out rightly rejected in the very first instance.
III. Definitions: The definitions in this Letter to be understood subject to exceptions.
a) Security Vendor: The word Security Vendor means any original manufacturer / authorized Supplier or Dealer or AMC provider of any of the Security & Safety or Fire related equipment, who will be submitting their offer /bid.
b) Equipment: The word equipment means any System/ Gadget/Components used for installing in the branches / offices etc for the purpose of Security, surveillance & Fire Safety etc.
c) Items: The items shall be the equipments shown in Para 1(i) from ‘a’ to ‘g’ including its sub-categories unless specified different.
IV. PRE-QUALIFICATION CRITERIA
a. Qualification criteria given below specify minimum Qualification criteria in various areas to
ensure that Security Vendor / his partner has necessary experience, expertise, financial strength
and skilled human resource to provide quality service to the Bank.
b. Documents are not transferable.
c. Provide documentary details wherever necessary.
d. Following are the mandatory requirements (Details of documentary proof required is
specified in brackets/ Italics)
1. Turnover should be over and above Rs 25 Lakhs per year during last 3 years. (Audited
Balance Sheet for (FY; 2016-17, 2015-16 & 2014-15)
2. Should have a presence & continuous experience in the market from the past 5 years with
experience in offering similar solutions. (Copies of work orders & value of work done)
3. Should be a registered firm
a. (Company – Registration Certificate, MoA & Board Resolution authorizing authority
to Authorised Signatory;)
b. Partership – Partnership deed and PoA authorizing authority to Authorised Signatory.
c. Proprietorship - letter of Proprietorship, ID Proof and Address Proof of Proprietor.)
4. Should be registered with authorities of GST(Copy of certificate)
5. Should have valid PAN Card(Copy of PAN)
a. Should be financially strong to undertake such kind of projects and should furnish (Bank
Solvency Certificate of minimum Rs. 5 Lakhs to establish the financial soundness of
the Company. (The Solvency Certificate shall be the latest i.e Not issued before 01/06/2017
)
6. Should be empanelled for similar services with PSBs / PSUs/Central/State Govt.
undertaking in Uttarakhand & UP. (Copies of work orders & Value of work done)
7. Should have effective infrastructure /workshop for undertaking repair of equipments in the
area of service required. (Proof of having the facility – Any legal document with certificate
issued by Govt. authority, lease deed etc which is in force).
8. Should must be an income tax assesses and should have filed IT return for the last three
Assessment Year.(ITR Acknowledgement for FY; 2016-17, 2015-16 & 2014-15)
5
e. Additional requirements, which may give weightage to the bidder in the evaluation process
1. ISO or other relevant Certifications
2. OEM certification exclusively in the name of Security Vendor, specifying maintenance
support.
V. SERVICES FROM SECURITY VENDOR – EMPANELMENT & SUPPORT
a. The Bank reserves the right for selection and finalization of empanelment as per laid on
procedures. The Security Vendors will be considered for empanelment only if it meets all
conditions specified in this letter and screening being done by the Bank.
b. Empanelment would be done for a period of 02 years from the date of finalization of the process /
approved date. The extension of empanelment for 02 more years may be done after carrying out
the yearly review by the Bank with regards to the performance & services of Security Vendors.
Technical as well as other Specification of various Items of all Categories shall be as specified in Appendix “B’’ (These are the minimum specification required).
Fresh Installation / New Equipment (items a-e)
c. After successful empanelment of Security Vendors, during the event of a new installation of any
system, either for a branch or for an independent ATM, the requirements of the individual items
may vary case to case and Quotation will be obtained from the empanelled Sec Vendors in sealed
envelopes and supply order will be given to the (L1) for supply/installation.
d. On the basis of costs specified above, the firm who stands L1 shall be awarded the project for
that particular case, which will not only reduce the time frame for installation but also gives a
transparent system of awarding the project.
e. Rates for passive components like wire & conduits shall not be taken in the price comparison as
the payment of those items will be made on actual only. Applicable taxes will also be extra.
f. Installation of each item shall be completed within 10 days of release of order which will be
intimated to the registered email id of the Security Vendor. In case of delay, due to any genuine
cause, Security Vendor may submit representation to RO within 4 days of issue of the order for
approval. RO reserves the right to accept the representation of not based on merit.
AMC of items (item –f)
g. After successful empanelment of Sec Vendors, AMC Quote will be asked for Annual AMC rate
from the empanelled Security Vendors in sealed envelope which will be scrutinized and rate of
AMC will be finalized by the Bank after taking account of Market value as well as related
aspects. Security Vendors who accepts the rate finalized by the Bank will be awarded with AMC
of various Branches. The Bank will take all possible steps to distribute Branches evenly to all
qualified Security Vendors, however, RO shall also consider factors like equal opportunities,
level of service and other aspects which are is in the interest of the Bank in addition to the price
factor, and shall reserves the right of awarding the job in each case. The region has the
jurisdiction of whole Uttarakhand and 04 districts of Uttar Pradesh. The sec vendor must
have to accept the A.M.C of districts of UP branches/ATMs along with main land.
h. This rate once accepted will be valid till completion of the empanelment.
i. In the case of additional installation / augmentation of equipments in an existing location, the
work may be awarded to the Security Vendor who is already providing AMC support for said
category for that Office, so that the compatibility and continuity in the support can be ensured,
however, rates will be that of approved rate chart.
6
j. Items under warranty:- Equipments already under warranty shall not be included in the AMC
charges. However, if the warranty expires during the currency of the AMC period, the cost of the
equipment may also be included on pro-rata basis for calculating AMC charges from the date of
expiry of warranty.
Scope and Coverage of the AMC:
The contract will be for a period of two years
During the visit the technician should check the systems thoroughly from all the points, regarding its
functioning and maintenance.
Date of servicing shall be noted on the control panel. Service technician should make an entry in the
alarm register at the branch mentioning the date of servicing, repairs carried out, battery/ cells
replaced.
Service technician should be in possession of valid Identity Card with photograph.
In case of any modification in the system or change of wiring or any major work, including running
wires through conduit etc, is suggested by the technician, an estimate of the expenditure involved to
be submitted to the Branch.
The servicing shall be carried out once in a quarter without fail and the period between mandatory
services shall not be less than 70 days & more than 90 days.
If any repair work is to be carried out, prior permission should be sought from controlling office.
The Service Charges exclude the cost of components required to be replaced.
In case the Security/Fire/CCTV systems is replaced with a new system and is under warranty, the
AMC would be applicable only after expiry of the warranty period.
All the staff members are to be made familiar with the operation, location of switches and
maintenance of alarm system.
If the system is beyond in-situ repairs, a standby system will be provided by the agency and the unit so taken
will be installed back duly repaired. Major repairs involving heavy expenditure will be done only after being approved by this office. Replacement of system will be recommended only if the system is beyond economic repairs.
k. Site response time: The AMC Security Vendor shall turn up for attending the problem within a
time period of 24 hours from the time of registering of the complaint, failing which may attract
penalty. This would not include bank holidays
l. Turn-around time: The AMC Security Vendor shall repair / replace/ provide solution within a
time period of 48 hours from the time of registering of the complaint. This would not include
bank holidays. In case the equipment could not be brought into working conditions within the
time specified above, the Security Vendor shall provide a substitute so that the working of the
system should continue, failing which may attract penalty. m. Preventive Maintenance visit by AMC Security Vendor (mandatory visit once in a quarter even
if the branch has not called):- At least one mandatory preventive Maintenance visit shall be
arranged by AMC provider once in each quarter even if there is no complaint from the branch.
Details of the visit shall be recorded in the equipment register and a copy in detail shall be
forwarded to RO.
n. Procedure for „On Call Visits‟, whenever required by branches to attend any complaint or
7
repairs: - ■ The branch will be making the telephone calls to register the complaint (on telephone
number of the AMC provider or by email, fax or letter).
■ While registering the complaint, a complaint number shall be generated, by service provider,
with date and time and inform branch as well as Security Cell RO.
■ Likely time of deputing the technician shall be informed to the branch by the Security
Vendor.
■ The branch shall make note of the complaint number (With date and time) in the security
equipment checking register.
■ When the technician from the AMC provider visits the branch / repairs the system, he shall
make entry against the complaint in the register with details of the defects, its rectification as
well as present status.
■ The Officer in charge of the branch shall endorse his remarks against rectification of each
and every complaint.
■ Maintenance / Repair log for each equipment shall be recorded and shall be kept updated in
the register.
■ Branch officials to ensure that the system is working fine before giving the sign off.
o. Service Report: The repairs shall be carried out at the branch itself (on site). In case the
equipment is required to be taken to the workshop for repairs, the replacement / stand by system
shall be provided by the AMC provider. Service report shall be duly completed after the closure
of the complaint which shall be signed by the technician and officer in charge. ■ First copy shall be handed over to the Branch.
■ Second copy shall be sent to RO security cell on weekly basis by the Security Vendor.
■ Third copy may be retained by the AMC provider as record.
■ Consolidated summary of branch visits shall be sent once in a quarter to Security Cell / RO;
eg first week of July, October, January and April. This shall include details of both
“Preventive Maintenance visits” as well as “On call visits”.
p. FE Fresh Installation / Re-filling.(item-g) Aspects specified in Para V d-f & Para V j,k will be
followed in the case of fresh installation.
q. In the case of re-filling, the Security Vendors who becomes L1 based on refilling charges of FEs
for a particular branch as specified in the approved rate list will be awarded with Re-filling job.
General:
r. RO will be considering factors like equal opportunities, level of service and other aspects
which are is in the interest of the Bank in addition to the price factor, and shall reserves the
right of awarding the job in each case for each category.
s. RO shall be intimating the minimum requirements of equipments in a standardized
manner and the Security Vendor shall ensure installation of the same within three months
in all Branches under AMC. No deviation in this shall be accepted. If found any deviation
after completion of a quarter, penalty clause shall be invoked.
VI. OTHER CONDITIONS
a. All entries in the Bids form should be legible and filled clearly.
b. If the space for furnishing information is insufficient, a separate sheet duly signed by the
authorized signatory may be attached.
8
c. No overwriting or cutting is permitted. However, the cuttings, if any, in the Letter / Application
must be initialed by the person authorized to sign the bids.
d. No costs incurred by the applicant in applying, in providing necessary clarifications or attending
discussions, conferences or site visits will be reimbursed by the Bank.
e. If the application is made by a partnership firm, it shall be signed by all the partners of the firm
with their full names and current addresses, or by a partner holding the power of attorney for the
firm for signing the application, in which case a certified copy of the power of attorney shall
accompany the application. A certified copy of the partnership deed, current address of the firm
and the full names and current addresses of all the partners of the firm shall also accompany the
application.
f. If the application is made by a limited company, it shall be signed by a duly authorized person
holding the power of attorney for signing the application in which case a certified copy of the
power of attorney shall accompany the application. The information furnished must be sufficient
to show that the applicant is capable in all respects to successfully complete the envisaged work
in respective category. Attested Board Resolution in this regard can also be attached in place of
PoA.
g. The evaluation will be based on the experience of the agencies and their financial capabilities and
may also include inspecting the works carried out by the agency for which necessary co-
ordination shall be made by the agencies. Based on the details furnished and inspection of works,
eligibility criteria, the agency shall be empanelled. Decision of the Bank regarding selection /
rejection for empanelment will be final and binding and no further correspondence will be
entertained. The empanelled agencies will only be informed by post /email.
h. If, information and details furnished by applicants are found to be false at any time in future or
any information withheld, which comes to the notice of the Bank at a later date, the empanelment
of such applicant will be cancelled immediately.
i. Bank reserves its right to reject any / or all the applications without assigning any reasons
whatsoever.
j. The Bank will not be responsible for the Bids received late on account of any reason.
Authorized Signatory
9
APPENDIX- “A”
To,
The Asstt. General Manager,
Security Cell
Syndicate Bank, Regional office,
46, E.C Road, IDA Tower
Dwarka Store
Dehradun-248001
Dear Sir,
Sub: Application for empanelment of Security & Fire Safety Gadgets.
1. Refer to your advertisement appeared in …………………………………….
dated……………………2017.
2. I / we hereby forward our application for empanelment of Security & Fire Safety gadgets in your bank /
RO as per the given Performa. I / We also hereby declare that the information furnished in the
application and in the supplementary sheets from pages …..…..to ……….are correct to the best of my /
our knowledge and belief.
Signature ______________________________
Name ____________________________________
Designation________________________________
Address __________________________________
__________________________________
Place:
Date:
Seal of Applicant:
1. Name of the Organization. :
2. Address. :
10
3. Year of Establishment :
4. Status of Firm :
(Whether Company/ Firm/ Proprietary)
(Enclose relevant document /deed)
5. Name of the Directors/Partners/Proprietor. :
i)
ii)
iii)
( Enclose relevant document / deed)
6. Whether registered with the Registrar of companies / :
Registrar of Firms. If so mention number and date.
7. a) Name & Address of the Bankers.
i) ii)
iii) iv)
b) Enclose the Solvency certificate from the Bankers :
( Give details)
c) Whether able to furnish performance guarantee for :
full cost of work if entrusted.
8. Whether registered for sales tax purpose if so mention :
number & date. Also furnish copies of sales Tax clearance
certificate.
9. Whether an assessment of Income Tax. If so, mention
permanent account number. Furnish copies of income tax
clearance certificate.
10. Furnish copies of audited balance sheet & profit & loss Account audited)
For the last 3 years.
11. If you are registered in the panel of other organizations/ statutory bodies such as CPWD, PWD, MES,
Banks etc. Furnish their names and date of registration.
i) ii)
11
iii) iv)
12. What is your field of activities? Mention the fields on preference basis:
i) ii)
iii) iv)
v) vi)
13. Whether willing to work anywhere in India or mention :
The place where you are willing to work.
14. i) Detailed description and value of work done for others in the past:
ii) Detailed description and value of work done for the Bank:
15. Specify the maximum value of work executed in a year.
16. Furnish the names of three responsible persons who will be in a position to certify about the quality as
well as past performance of your organization.
i)
ii)
iii)
Note: Where copies are required to be furnished, these are to be certified copies preferably by the concerned
agencies or a Govt Office
12
Proforma – 1
Particulars in respect of work executed.
SI.
No.
Name of work
project with
address
Short
description of
work executed
Name &
address
of owner
Value of
work
executed
Stipulated
time of
completion
Actual
time of
completion
Name &
address of
Architect
consulting
engineer.
1 2 3 4 5 6 7 8
Proforma – 2
Key Personnel Permanently employed.
SI.
No.
Name Designation Qualification Experience Years with the
firm
Any other
1 2 3 4 5 6 7
13
Proforma – 3
Other relevant Information
I. Work Force
Permanently employed No. Any other Years with Firm
a) Executives
b) Managers
c) Technicians
d) Others
II. Workshop Facilities
Location Land Area Type of Structure Type of facilities
a)
b)
14
“Appendix-B”
SPECIFICATION AND QUALITATIVE REQUIREMENTS OF SECURITY AND FIRE SAFETY
EQUIPMENTS
(No Conditional acceptance / Compliance will be entertained)
I.Security Alarm System for Branch/Office/attached ATMs
Depending upon the ambience and technical feasibility, the security alarm system can be wireless operating
within the permissible frequency bands or wired system as may be decided by us. The system shall have following
broad specifications:
S No
Tech Specifications / Requirements Complied / Not Complied
1. The Control Panel should operate on 180 - 240V mains supply via step-down transformer. Zone indicator facility for 4-10 switches with provisions to extend the same as per requirement with display on the control panel shall be available.
2. Control panel/ unit should have Maintenance free automatic re-chargeable 12VDC x l.3 - 7 AH MF Battery backup. System should automatically change over to battery on power failure and to mains when the power is restored. The Control Panel should be PCB based modular circuitry and have Low Power consumption.
3. The System should have following sensors or should be compatible to provide interface without any additional modifications.
Magnetic sensors
Passive Infra Red sensors (Min 25 feet range) Model DSC-CL-100 or
higher
Light detection sensors
Auto Dialer
Shutter magnetic switch
Pressure mats sensors
Glass break detector
Central Monitoring System (CMS)
4. The System operating frequency should have immunity to external Radio Frequency interference.
5. The following Visual indications on the control panel shall be provided:
System on
Battery charging
Battery Low
Battery indication when system under Battery backup.
Indications on tamper condition of external speaker, wire or Control
panel.
Night mode functional indicator
Day mode functional indicator
Each of channels to be provided
15
6. Compatible for provision of Night mode functional indicator at the entrance.
7. Built-in speaker in control unit (25 Watt).
8. Unit body fabrication to be of combination minimum 18 SWG and 14 SWG, with no screws accessible from outside including mounting screws. Front cover to be lockable and designed to be wall-mounted. Corrosion-proof steel metallic body having tamper-proof locking arrangements.
9. Automatic faulty zone/switch isolation should be available in the control panel.
10. Key and lock for ON and OFF function of the system and also for unit locking should be provided.
11. Automatic shut off of alarm after a preset time. Also the siren should be switched off by turning the key switch to armed position.
12. Entry and Exit Delay (adjustable). The Exit/entry time duration should be indicated by the buzzing of the buzzer.
13. Audio-visual testing facility of Alarm System without activating the main speaker should be available (Test button and indication).
14. Miniature Circuit Breaker (MCB) safety device to be provided to prevent damage to the Alarm System due to high/low voltage, surge/fluctuation.
15. Full tamper-proof circuit, wiring and system. On tampering of any part, the siren should sound.
16. ISI approved wiring and 1 inch ISI marked white PVC conduit. All wiring should be concealed in conduit.
17. External wiring: For panic switch: - Super annealed solid copper wire 0.5 mm diameter insulated to withstand minimum 1100V. For speakers: twin 25 strand copper wire of minimum 36 SWG twisted, flexible and insulated.
18. Operating temperature: -10° C to +55° C. Humidity: 10% to 90% non-condensing. Vibration, Tremors and normally applied jerks resistant.
19. Immunity to static lightning. Minimum 40 Watt (main) external speaker.
20. System should have warranty for minimum one year.
21. Control panel should have lockable strong metal case and it should be installed in a place away from customer service area in a concealed manner.
22. All cabling should in concealed manner
23. The Auto Dialer shall have the following basic features:
Minimum 08 telephone numbers feeding facility
Able to feed minimum 16 Digit telephone number (each)
Message shall pass on to the next telephone number automatically in case of no response in a sequential manner (as fed in the memory).
24. Training to be provided to selected branch personnel / guard of the Branch / Office to operate the system
25. The Security Alarm System should be subjected to Performance test and certified by Regional Electronics Test Laboratory or Electronics Test and Development Centre (ET & DC) of Ministry of Information Technology, Govt. of India.
26. Panic button to be positioned inside ATM room and magnetic sensor to be positioned on the bottom side of the ATM machines Vault door. Alarm should activate two Hooters of 10W each positioned inside and outside ATM room when either of this buttons is activated.
27. Self-Test facility
28. Power connectivity shall be from UPS
29. Sensors, switches and other accessories should be tamper proof and should be installed in sufficient height where ever required
30. In attached ATMs; Panic button to be positioned inside ATM room and magnetic sensor to be positioned on the bottom side of the ATM machines Vault door. Alarm should activate two Hooters of 10W each positioned inside and outside ATM room when either of this buttons is activated.
16
31. Panic button inside the ATM room shall be placed in the center of white acrylic board with inscription in red as shown below.
II. SPECIFICATIONS/ FEATURES FOR DVR BASED CCTV SYSTEM
The DVR shall of REPUTED MAKE LIKE- SAMSUNG, BOSCH, DEDICATED MICROS (UK), HIKVISION, DAHUA,
ETC.
Make for all types of Camera - Reputed Make Like Samsung, Bosch, Dedicated Micros (Uk), Hikvision, Dahua,
etc which are (CE/FCC certified).
S No
Tech Specifications / Requirements Complied / Not Complied
1. Digital Video Recorder(DVR) 04/08/16 channel – stand alone (UL/FCC/CE approved)
2. Stand alone Digital Video Recorder (DVR) 1.5 U, H.264 compression algorithm for standalone DVR
3. Real time Live display with 4/8/16 cameras 720P high definition.
4. Remote and live display for 4/8/16 cameras,
5. 480 fps recording for CIF and D1 (4ClF) function;
6. Live, recording, playback, backup and network and Mobile access, multi/upto 4 Hard Disc drives (HDDs) and DVD-RW supported, all channels simultaneous playback.
7. Multiple control methods; front panel, IR remote controller, USB mouse, network keyboard Smart video detection: motion detection, camera blank, video loss.
8. Smart camera settings privacy masking, camera lock, color setting and title display.
9. Pan Tilt Zoom and Speed Dome Control; multi protocols supported, preset, scan, auto pan, auto tour, pattern, auxiliary function supported.
10. 8 channels and audio inputs- bidirectional talk supported.
11. Back-up methods: USB devices, DVD-RW and network download.
12. Alarm triggers screen tips; boozer, PTZ movement supporting, e-mail and FTP upload.
13. Smart HDD management: non working HDD hibernation faulty alarm,
14. multi DVR client CMS network access for remote viewing, recording, playback, setting, system status event log, email and FTP Function (UL CEFCC certified).
15. Multi password protection.
16. Maximum record rate upto 50 pps(PAL),
17. Built in Activity/Motion detection,
18. Schedule recording, 10/100 base – T network interface capability,
19. Virtual Keyboard
20. HDD capacity to accommodate 90 days recording for Branches / ATMs and 180 days for CC.
21. Dual Stream facility (masking of some cameras),
22. Powerful network software: Remote viewing with PC connectivity, built-in web server, multi-DVR client & CMS. Network access for remote live viewing, recording,
Emergency Call
(Panic Switch)
Police 100
17
playback setting, system, status, event log, e-mail & FTP function (UL / CE/ FCC certified).
23. Monitor – Minimum 19” TFT/ Flat screen/LCD, CE/FCC certified (Samsung/ LG/ Sony) Make.
Cameras:
24. DOME – Make-(Sony/Samsung/ Dahua) (CE/FCC certified)
a. Sensor-1/3” Sony chip super HAD CCD with 3.6mm lens with 12 V regulated power supply.
b. Video Processing – DSP
c. Effective Pixels -752(H) x 582(V)
d. Sensitivity – 0.7 lux for usable picture(40% video) with IRE AGC on
e. Resolution- 700 TVL
f. Video output- 1.0 Vpp, 75 ohm unbalanced
g. S/N ratio – 50 db
h. White balance- ATW
i. AGC – Yes
j. Gamma Correction – 0.45
25. DOME (IRLED/ Night Camera)- Make-( (Sony/Samsung/Dahua)) CE/FCC certified.
a. Sensor – 1/3” Sony chip Super HAD CCD with 3.6mm lens
with 12V regulated Power supply.
b. Video Processing – DSP
c. Effective Pixels -752(H) x 582(V)
d. Sensitivity – 0.7 lux for usable picture(40% video) with IRE
AGC on
e. Resolution- 700 TVL
f. Video output- 1.0 Vpp, 75 ohm unbalanced
g. S/N ratio – 50 db
h. White balance- ATW
i. AGC – Yes
j. Gamma correction – 0.45
26. “C” Mount – make – ((Sony/Samsung/Dahua)) CE/FCC certified.
a. Sensor – 1/3” Sony chip Super HAD CCD with 3.6mm lens
with 12V regulated Power supply.
b. Video Processing – DSP
c. Effective Pixels -752(H) x 582(V)
d. Sensitivity – 0.7 lux for usable picture (40% video) with IRE
AGC on
e. Resolution- 700 TVL
f. Video output- 1.0 Vpp, 75 ohm unbalanced
g. S/N ratio – 50 db
h. White balance- ATW
i. AGC – Yes
j. Gamma correction – 0.45
27. Bullet Body IR camera – make – (Sony/Samsung/Dahua) CE/FCC certified
a. 750 TVL,
b. Minimum luminance less than 1.0 Lux (F2.0),
c. S/N Ratio More than 48dB,
d. Internal Sync System,
e. Aesthetic design,
f. Automatic electronic shutter system,
18
g. Low Light Surveillance Support
h. Automatic Gain Control,
i. Mounting Bracket Included
j. Compact Design
28. Pin Hole camera – make – (Sony/Samsung/Dahua) CE/FCC certified
a. Pick Up Device - 1/3" Pixim DPS Sensor
b. Horizontal Resolution - 700 TVL
c. View Angle (Horizontal) - Min 66º
d. Dynamic Range - Typical: 102dB / Max: 120dB ( Off / Standard / High )
e. Min. Illumination 0.8 Lux / F1.2
f. Electronic Shutter Control - Built-in
g. Back Light Compensation On / Off selectable
h. S/N Ratio More than 50dB ( AGC off )
i. White Balance
j. Video Output
k. Auto Gain Control
l. Noise Reduction Auto
m. Protective Housing – Metal Cabinet
29. Cable – RG 6 / RG 59 multi core coaxial cable for connecting cameras to the DVR & for connecting the power supply to the cameras of reputed branch/make.
Other CCTV system requirements:
30. Required latest Software (licensed) for complete system. System & software warranty of 12 months from the date of installation/commissioning.
31. Inbuilt Motion Detection Device – In tandem with CCTV cameras, of reputed brand/make.
32. 90 days recording facility.
33. All Cabling should in concealed manner.
34. Any electrical wiring that may be required for specifications & of reputed brand/ make (ISI marked).
35. Able to provide facility to preview, record & play back the events at a time and should be highly secure & temper proof and easy to trace.
36. Easy system to playback / copy the recording into CD or Pen Drive without disruption of the recording process.
37. Redundant power supply to the CCTV system
38. System should have warranty for minimum one year.
39. Cameras to be placed to cover all access points /parking area /outer periphery of the premises, other activity area inside the bank and other vulnerable points of the branch / ATM in addition to strong room /safe room and cash handling area of the branch.
40. CCTV System should have Night/Low Light Intensity Mode facility and automatic change-over to the same.
41. Control Panel/ DVR System/monitor should be placed so that it is not visible for general public
42. The system should be compatible/ able to configurative multiple cameras which should be above to capture real-time video images & provided video output to view & record the events.
43. Training to be provided to selected branch personnel / guard to operate the system
44. Vandal proof facility should be available for all camera meant for ATMs.
45. Metal covering / Housing for pin hole camera / DVR for ATM should be included.
19
46. Camera Mount should be included.
47. Audio interface card should be included in Camera
48. DVR system should be able to perform the following functions:
Display the images in the monitor
Record the events & store in the hard disc
Provide replay of the events(smart search)
Event recording through Motion Detection, scheduling, alarms trigger & continuous recording & time lapse modes.
Multiple password authorization for high degree of security.
Event logging for video loss, motion detection, power on/off,
user login etc.
49. Software requirements:
Browsing mode – Multi/single channel. Camera images outputs in digital format to be displaced as single/multiple channels on monitor screen.
Video Recording Mode – Manual/ continuous / scheduled/ event based Record digital images on local hard disc via manual selection or continuously (24x7) or scheduled for day & time or if motion is detected.
Video play back at variable speed
Image compression – Latest digital compression technique.
Multi level password protection
Motion sensitivity levels
Motion detection
III. ACCESS CONTROL SYSTEM
The proximity card based access control system for designated entrances that are in use at present shall
have following basic technical specifications:
S No
Tech Specifications / Requirements Complied / Not Complied
1. Work in two-factor identifications (Proximity Card and PIN)
2. Single Door Controller model with built in Reader, built-in key board.
3. Electromagnetic lock with fail-safe holding force of minimum 600lb (300kg).
4. Regulated Power Supply 12 V, 500 MA.
5. Four Digit PIN number.
6. Exit Push Button.
7. Proximity Cards.
8. Preferably, the controller shall have compatibility with Window based software for
In and out record data memory of up to 2000 records.
Support the Alarm System with various functions such as distressed
alarm, night/ day alarm.
Group Management.
9. The basic feature of Biometric (finger print) access control system:
Finger print capacity of 1900
20
Should be capable of integrated with computer and Soft/Hard copy of
all the entry data can be generated.
Electromagnetic lock 600 lb capacity
IV. AUTOMATIC FIRE DETECTION AND ALARM SYSTEM (AFDAS)
All fully computerized Branches (TBM), CBS Branches and IT Cells should be installed with Automatic Fire
Detection and Alarm System (AFDAS).
S No
Tech Specifications / Requirements Complied / Not Complied
1. AFDAS should be selected, maintained and installed in terms of guidelines laid down in Indian Standard:2189:1988. Should have been certified by the Regional Electronic Test & Development Centre, Dept of Electronics, Govt of India for fulfilling technical specifications given as per IS:2189.
2. Electrical installation pertaining to the entire Fire Alarm System should be independent of other systems. Standby power supply like battery supply with automatic changeover or UPS should be available and must be capable of maintaining the system in normal operation for a period of not less than 48 hours after the failure of main power supply.
3. The recommended scale of installation in TBM branches/ EDP centres is as follows:
Type Area
Smoke Detector Units
(ionization type)
At the rate of one unit per area of 15'x15' or
fraction thereof equally distributed in the cabins
where computer servers/ UPS are located
Smoke Detector Units In general areas at the rate of one unit per area of
20'x20' where PCs are kept in general work area of
the branch/ office.
4. A minimum distance of 1.5 Meter should be maintained between air diffusers (if centralized air conditioning is provided) and detector point.
5. Detectors should not be mounted within 500 mm from walls or partitions or any obstruction. In case of minor obstruction like light fitting, a clearance of 250 mm should be maintained.
6. A mimic panel or drawing which has a plan of floor reduced to scale to identify the zone of fire should be provided near alarm control panel.
7. Miniature Circuit Breaker (MCB) safety device to be provided to prevent damage to the Alarm System due to high/low voltage, surge/fluctuation.
8. Manual Call Points (MCPs) should be fixed at a height of 1.4 meter from the floor level. Such MCPs should preferably be located near the entry to the stair case/ door.
9. Two Zones control panel (with the facility for incorporating auto dialer) will be sufficient for normal size CBS Branches. The Zones may be increased depending upon the size of the CBS/ Offices. Incorporation of Auto dialers in the AFDAS is a mandatory requirement. The telephone numbers of Branch Head, Dy Branch Manager, other staff, Fire Brigade and local Police Station may be programmed into the Auto dialer.
10. Control Panel should have Specification as below (should also comply points specified in 4(i) to 4(ix):
21
a) Operation on 230 V AC supply with solid state electronic circuitry with built in electronic hooter.
b) Visual Zone indicators.
c) Audio alarm device incorporating the acknowledge indicators for Fire Condition, Fault Condition, AC Battery Failure indicators, Low Battery indicators, Blown Fuse indicators, AC pilot indicators, Open and short circuit fault, Push buttons to disable audio alarm/ testing each zone, reset and acknowledge reset and test device should be provided.
d) Modular design using electric plug-in printed circuit board.
e) 2 Zone control panel with 7 AH, 2x12 Volt DC Battery back-up and Battery Rechargeable system (needed by an average sized branch).
f) Panel fabricated from mild steel (MS) Sheet with front acrylic sheet door with built in Buzzer. Provided with Main operating controls such as isolation, test, fault, AC failure, Battery Charger indicator and voltmeter.
g) The Auto Dialer shall have the following basic features:
Minimum 08 telephone numbers feeding facility
Able to feed minimum 16 Digit telephone number (each)
Message shall pass on to the next telephone number automatically in case of no response in a sequential manner (as fed in the memory).
11. Detectors:
· Ionization Smoke detector Apollo make Series 65
· Optical Smoke detector -do-
· Heat detector -do-
12. Cable: Two core 1.5 sq mm PVC insulated armored copper conductor cable ISI:1554 (Part I): 1998 marked.
13. Other Accessories Electronic hooter complete with diaphragm type speaker of 6 watts.
Remote Response Indicator (RI).
Manual Call Point (MCP) button (pill box) with Mild Steel Body.
V. Integrated Fire & Security Alarm System for ATMs
Depending upon the ambience and technical feasibility, the security alarm system can be wireless operating
within the permissible frequency bands or wired system as may be decided by us. The system shall have following
broad specifications:
S No
Tech Specifications / Requirements Complied / Not Complied
1. The Control Panel should operate on 180 - 240V mains supply via step-down transformer. Zone indicator facility for 4-10 switches with provisions to extend the same as per requirement with display on the control panel shall be available.
2. IC based control circuitry only, containing relay switch 12 V, capacitor minimum 3 numbers transistors and resistors with Diode (12 numbers)
22
3. The control unit should cater for future requirements such as GSM, CMS etc.
4. Control panel/ unit should have Maintenance free automatic re-chargeable 12VDC x l.3 - 7 AH MF Battery backup. System should automatically change over to battery on power failure and to mains when the power is restored. The Control Panel should be PCB based modular circuitry and have Low Power consumption.
5. The System should have following sensors or should be compatible to provide interface without any additional modifications.
Magnetic sensors
Passive Infra Red sensors (Min 25 feet range) Model DSC-CL-100 or higher
Light detection sensors
Auto Dialer
Shutter magnetic switch
Pressure mats sensors
Glass break detector
Central Monitoring System (CMS)
Smoke detection
Fire detection
6. The System operating frequency should have immunity to external Radio Frequency interference.
7. The following Visual indications on the control panel shall be provided:
System on
Battery charging
Battery Low
Battery indication when system under Battery backup.
Indications on tamper condition of external speaker, wire or Control panel.
Night mode functional indicator
Day mode functional indicator
Each of channels to be provided
8. Compatible for provision of Night mode functional indicator at the entrance.
9. Built-in speaker in control unit (25 Watt).
10. Unit body fabrication to be of combination minimum 18 SWG and 14 SWG, with no screws accessible from outside including mounting screws. Front cover to be lockable and designed to be wall-mounted. Corrosion-proof steel metallic body having tamper-proof locking arrangements.
11. Automatic faulty zone/switch isolation should be available in the control panel.
12. Key and lock for ON and OFF function of the system and also for unit locking should be provided.
13. Automatic shut off of alarm after a preset time. Also the siren should be switched off by turning the key switch to armed position.
14. Entry and Exit Delay (adjustable). The Exit/entry time duration should be indicated by the buzzing of the buzzer.
15. Audio-visual testing facility of Alarm System without activating the main speaker should be available (Test button and indication).
16. Miniature Circuit Breaker (MCB) safety device to be provided to prevent damage to
23
the Alarm System due to high/low voltage, surge/fluctuation.
17. Full tamper-proof circuit, wiring and system. On tampering of any part, the siren should sound.
18. ISI approved wiring and 1 inch ISI marked white PVC conduit. All wiring should be concealed in conduit.
19. External wiring: For panic switch: - Super annealed solid copper wire 0.5 mm diameter insulated to withstand minimum 1100V. For speakers: twin 25 strand copper wire of minimum 36 SWG twisted, flexible and insulated.
20. Operating temperature: -10° C to +55° C. Humidity: 10% to 90% non-condensing. Vibration, Tremors and normally applied jerks resistant.
21. Immunity to static lightning. Minimum 40 Watt (main) external speaker.
22. System should have warranty for minimum one year.
23. Control panel should be housed in lockable strong metal case of 22 gauge metal box and should be installed in the UPS Box of ATM Room away from customer service area.
24. All cabling should in concealed manner
25. The Auto Dialer shall have the following basic features:
26. Minimum 08 telephone numbers feeding facility
27. Able to feed minimum 16 Digit telephone number (each)
28. Message shall pass on to the next telephone number automatically in case of no response in a sequential manner (as fed in the memory).
29. Training to be provided to selected branch personnel / guard to operate the system
30. The Security Alarm System should be subjected to Performance test and certified by Regional Electronics Test Laboratory or Electronics Test and Development Centre (ET & DC) of Ministry of Information Technology, Govt. of India.
31. Panic button to be positioned inside ATM room and magnetic sensor to be positioned on the bottom side of the ATM machines Vault door. Alarm should activate two Hooters of 10W each positioned inside and outside ATM room when either of this buttons is activated.
32. Panic button inside the ATM room shall be placed in the center of white acrylic board with inscription in red as shown below.
33. Time with 5 minute auto cut. Reset the switch to cut off the hooter & rest the circuit.
34. Self-Test facility
35. General aspects of Alarm specified in Para I shall be undertaken
36. Power connectivity shall be from UPS
Emergency Call
(Panic Switch)
Police 100
24
VI. SPECIFICATIONS/ FEATURES FOR DVR BASED CCTV SYSTEM –
The DVR (ATM Specific with in-built Monitor) shall of REPUTED MAKE LIKE- SAMSUNG, BOSCH, DEDICATED MICROS
(UK), HIKVISION, DAHUA, ETC.
S No
Tech Specifications / Requirements Complied / Not Complied
1. Stand alone Digital Video Recorder (DVR) 1.5 U, H.264 compression algorithm for standalone DVR
2. In built Monitor (5.56 Inch)
3. Real time Live display ; 720P high definition.
4. Remote and live display,
5. 480 fps recording for CIF and D1 (4ClF) function;
6. Live, recording, playback, backup and network and Mobile access, multi/upto 2 Hard Disc drives (HDDs) and DVD-RW supported, all channels simultaneous playback.
7. Multiple control methods; front panel, IR remote controller, USB mouse, network keyboard Smart video detection: motion detection, camera blank, video loss.
8. Smart camera settings privacy masking, camera lock, color setting and title display.
9. Pan Tilt Zoom and Speed Dome Control; multi protocols supported, preset, scan, auto pan, auto tour, pattern, auxiliary function supported.
10. 4 channels and audio inputs- bidirectional talk supported.
11. Back-up methods: USB devices, DVD-RW and network download.
12. Alarm triggers screen tips; boozer, PTZ movement supporting, e-mail and FTP upload.
13. Smart HDD management: non working HDD hibernation faulty alarm,
14. multi DVR client CMS network access for remote viewing, recording, playback, setting, system status event log, email and FTP Function (UL CEFCC certified).
15. Multi password protection.
16. Maximum record rate upto 50 pps(PAL),
17. Built in Activity/Motion detection,
18. Schedule recording, 10/100 base – T network interface capability,
19. Virtual Keyboard
20. HDD capacity to accommodate 90 days recording for Branches / ATMs and 180 days for CC.
21. Dual Stream facility (masking of some cameras),
22. Powerful network software: Remote viewing with PC connectivity, built-in web server, multi-DVR client & CMS. Network access for remote live viewing, recording, playback setting, system, status, event log, e-mail & FTP function (UL / CE/ FCC certified).
23. Cable – RG 6 / RG 59 multi core coaxial cable for connecting cameras to the DVR & for connecting the power supply to the cameras of reputed branch/make.
Other CCTV system requirements:
24. Required latest Software (licensed) for complete system. System & software warranty of 12 months from the date of installation/commissioning.
25
25. Inbuilt Motion Detection Device – In tandem with CCTV cameras, of reputed brand/make.
26. 90 days recording facility.
27. All Cabling should in concealed manner.
28. Any electrical wiring that may be required for specifications & of reputed brand/ make (ISI marked).
29. Able to provide facility to preview, record & play back the events at a time and should be highly secure & temper proof and easy to trace.
30. Easy system to playback / copy the recording into CD or Pen Drive without disruption of the recording process.
31. Redundant power supply to the CCTV system
32. System should have warranty for minimum one year.
33. Cameras to be placed to cover all access points /parking area /outer periphery of the premises, other activity area inside the bank and other vulnerable points of the branch / ATM in addition to strong room /safe room and cash handling area of the branch.
34. CCTV System should have Night/Low Light Intensity Mode facility and automatic change-over to the same.
35. Control Panel/ DVR System/monitor should be placed so that it is not visible for general public
36. The system should be compatible/ able to configurative multiple cameras which should be above to capture real-time video images & provided video output to view & record the events.
37. Training to be provided to selected branch personnel / guard to operate the system
38. Vandal proof facility should be available for all camera meant for ATMs.
39. Metal covering / Housing for pin hole camera / DVR for ATM should be included.
40. Camera Mount should be included.
41. General aspects of CCTV System specified in Para II shall be undertaken
42. The DVR shall be kept in UPS Box in case of ATM away from the Branch. If ATM is adjacent to the Branch, DVR may be kept inside the Branch and the wiring to the Camera may be in concealed manner.
43. Power shall be from UPS
44. Audio interface card should be included in Camera
45. DVR system should be able to perform the following functions:
46. Display the images in the monitor
47. Record the events & store in the hard disc
48. Provide replay of the events(smart search)
49. Event recording through Motion Detection, scheduling, alarms trigger & continuous recording & time lapse modes.
50. Multiple password authorization for high degree of security.
51. Event logging for video loss, motion detection, power on/off, user login etc.
Software requirements:
52. Browsing mode – Multi/single channel. Camera images outputs in digital format to be displaced as single/multiple channels on monitor screen.
53. Video Recording Mode – Manual/ continuous / scheduled/ event based Record digital images on local hard disc via manual selection or continuously
26
(24x7) or scheduled for day & time or if motion is detected.
54. Video play back at variable speed
55. Image compression – Latest digital compression technique.
56. Multi level password protection
57. Motion sensitivity levels
58. Motion detection
59. Video Analytic Software
VII. Other Terms and Conditions:
S No
Tech Specifications / Requirements Complied / Not Complied
1. The FEs should comply to latest BIS standards i.e BIS Specification IS: 15683 or latest.
2. All new equipments shall contain minimum 1 year warrantee.
3. All equipments whenever being placed outside the building should be self protective and housed in tamper proof / whether proof casing / housing.
4. No separate installation charges / Refilling Charges / Freight Charges shall be permitted.
5. In the case of refilling, the old FE may be used for Demonstration purpose for branch staff as well as Guard.
6. A slip indicating the name, address and telephone number of the vendor, date of refilling and next refilling due date (as specified above) should be pasted on each Fire Extinguisher
7. Periodicity of Refilling
Type of FE Periodi
city
Remarks
DCP 2 Yrs Drying of DCP Powder once a year (where
applicable) so that it does not become cake / solid
Water CO2 9ltrs 2 Yrs Replacement / filling of clean water once in 6
months so that water do not become rusty
ABC powder
pressure stored
2 Yrs
CO2 stored Gas 1 Yrs As soon as the fire extinguisher is used or gas is
leaked or pressure is less than installed on
pressure guage.
8. No separate installation charge shall be paid
9. Applicable Taxes may be extra
10. This quote shall be valid for present empanelment period i.e upto 31 Dec 2015.
11. All new equipments shall contain minimum 1 year guarantee.
12. All equipments being placed outside the building should be self protective and housed in tamper proof / whether proof casing / housing.
13. Cameras, sensors, witches should be tamper proof and should be installed in sufficient height where ever required.
27
14. The prices shall be quoted as per the given price bid format only.
15. Work order shall be placed for individual Branches / nodes separately.
16. You may undertake the site survey and provide the bill of material as well as installation plan within 3 days to the RO.
17. The BoM and installation plan will be finalized by RO.
18. Installation of each location should be completed within 7 days of receipt of approval from RO.
19. Bills may be raised based on number of equipments / passive components installed in each site. Payment for each Branch / Off-Site ATM may be done as per actual only.
************