EMISSION PROBE PARTS TUBE: 3/8” OD x 0.049 wall Stainless Steel Length determined by pipe diameter and placement of connecting end to allow easy connection of the heated sample line. Long tubes may be bent to place connection end in desirable location. 3/8 Nut-Ferrule sets (Swagelok SS-600-NFSET) Probe Adapter: Swagelok fitting SS-600-1-4BT (3/8 NPT to 3/8 Tube, Bored Through) Cap Tube with Swagelok Cap SS- 600-C (if keeping probe installed) Or Plug Adapter with Swagelok Plug SS-600-P (if probe is removed) 45 o Mitered End

EMISSION PROBE PARTS

  • Upload
    nyla

  • View
    26

  • Download
    0

Embed Size (px)

DESCRIPTION

EMISSION PROBE PARTS. Cap Tube with Swagelok Cap SS-600-C (if keeping probe installed) Or Plug Adapter with Swagelok Plug SS-600-P (if probe is removed). 3/8 Nut-Ferrule sets (Swagelok SS-600-NFSET). TUBE: 3/8” OD x 0.049 wall Stainless Steel - PowerPoint PPT Presentation

Citation preview

EMISSION PROBE PARTS

TUBE:

3/8” OD x 0.049 wall Stainless Steel

Length determined by pipe diameter and placement of connecting end to allow easy connection of the heated sample line. Long tubes may be bent to place connection end in desirable location.

3/8 Nut-Ferrule sets(Swagelok SS-600-NFSET)

Probe Adapter: Swagelok fitting SS-600-1-4BT(3/8 NPT to 3/8 Tube, Bored Through)

Cap Tube with Swagelok Cap SS-600-C (if keeping probe installed)

Or

Plug Adapter with Swagelok Plug SS-600-P (if probe is removed)

45o Mitered End

EMISSION PROBE INSTALLATION

Scribe Line to Identify

45o Mitered Face

Weld/braze adapter fitting to exhaust pipe

(Do NOT use epoxy as shown in this mock-up)

Mitered face in center of pipe and facing upstream

Check the rules regarding probe locations. The probe can NOT be located near the end of the pipe as shown in this mock-up

COUPLER ORIENTATIONFor all Quick Disconnect couplers (fuel, coolant, supply, return);

Flow is out of the male coupler and into the female coupler.

NOTE: Contact [email protected] to request couplers (provided free of charge to registered teams).

FLOW

FLOW

FLOW

FLOW

COOLANT COUPLERS

The black, Coolant Couplers shown above have been discontinued. New couplers, white, slightly smaller, and also with a ¾” hose barb, MUST BE USED. The new couplers will not mate with the old style couplers. For information on the new HFC couplers: http://www.colder.com/Products/tabid/693/Default.aspx?ProductId=14

Hot Coolant from Engine into Heat Exchanger

Cooled Coolant into Engine

Inlet line and Outlet line are each 80” long

Closed Loop Engine Cooling SystemUtilizing a brazed plate Heat Exchanger

(Closed Loop = Pressure can build up to radiator cap’s relief pressure)

Cold Side of Heat Exchanger

Temperature Regulating Valve opens based on the temperature of the coolant returning to the engine

Engine

Colder Male Quick DisconnectOPTIONAL

Colder Female

Quick Disconnect

Participant’s Responsibility

Test Facility Responsibility

FUEL SYSTEM for EMISSION TESTINGThe sled’s fuel tank must be disconnected so that the test facility’s fuel measuring system supplies all the fuel. The test facility will supply a low pressure fuel. Teams need to supply their own external fuel pump and regulator to ensure that the engine receives fuel at the correct pressure.

Teams must have the Colder Quick Disconnects installed for both emission events. For the in-service emission event, take into consideration accessibility of the QD’s and routing of the external fuel line(s). The QD’s are not required during the other events in the competition.

Questions regarding the emission fuel system requirements should be directed to [email protected].

Fuel Tank

Fuel Return Line

Colder Female Quick DisconnectOPTIONAL Colder Male Quick Disconnect

(if have a return line)

MassFlow Meter

FuelSupply

FuelCooler

Fuel Supply

Regulator

Low Pressure1-5 psi

Low Pressure Fuel Feed to Engine

Fuel Supplied at Low Pressure

High Pressure

PUMP

Filter TransferPump

Fuel Return line

(if required)

High Pressure Fuel to Regulator/engine

Facility FUEL SystemMust measure all fuel consumed during the emission events

External Fuel Pump

Must be supplied by teams needing Fuel Pressure greater than 3-5 psi

Facility

Fuel Return line

Facility

Fuel Supply line

3 -5 psi

During the In-Service Emission Event The facility's fuel lines must run from the engine to the emission test sleigh

Fuel Couplers should be located to provide easy access and allow the cowling to be closed during the In-Service emission test.