10
EMISSION CONTROL ENGLISH

EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

EMISSION CONTROL ENGLISH

Page 2: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

2

Exhaust gas analysis module with infrared rays, to link up to the PC’s serial port.

Its small size and 12 V d.c power supply mean it can be used as a portable tool in situations where this is necessary.

Equipped with proprietary software OMNIBUS 800 Brain Bee, for installation on PC, carries out various operations that help the operator to fine tune the vehicle’s anti-pollution devices:

OFFICIAL VEHICLE INSPECTION TESTS AND FOR BLUE QUALITY-GUARANTEE STICKERIn accordance with Decreto DM/628 and successive circulars, AGS-200 enables you to carry out the official test in the vehicle inspection procedure.

CARBURATION CURVE It automatically memorises the value of the gases at different engine revolutions and displays the carburation curve. Particularly recommended for road tests or tests with power test bench.

AUTOMATIC DIAGNOSISThe software compares the gas values and provides the operator with a list of possible causes of the engine’s poor functioning.

CATALYTIC CONVERTER EFFICIENCY The software guides the operator through the test and provides the catalytic converter’s percentage efficiency each gas analysed both before and after the said converter.

DOUBLE LAMBDA SENSOR TESTUsing the oscilloscope function it analyses the variations in the signal and provides an operating efficiency value.

CYLINDER-HEAD TIGHTNESS TESTThe software guides the operator through the test and by analysing the gases inside the cooling liquid bottle is able to establish whether there are any infiltrations from the cylinder-head gasket.

HEATING EFFICIENCY TESTBy memorising the values of the gases for 30 minutes, the software is able to establish whether the auxiliary starter elements and temperature elements are working correctly.

FUNCTIONS

AGS-200EXHAUST GAS ANALYSER

AGS-200: MORE INFORMATIONS ON WWW.BRAINBEE.COM

EMISSION CONTROL

ACCESSORIES EMISSION CONTROL (*)

COMPLETE SOLUTIONS FOR BRAIN BEE INSTRUMENTS

The Brain Bee Chassis, Supports and Accessories line is designed to guarantee the utmost flexibility and versatility of the solutions the garage owner gradually adopts.

Designed in a modular way, it allows garage professionals to complement their own tools as they see fit, without having to worry about any sunk investments.

(*) ACCESSORIES line for: AGS-200; AGS-688; AGS-690; OPA-100; OPA-300; MGT-300

Page 3: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

3

The device samples the exhaust gas by means of its probe, supplied as a standard.By means of its simple keyboard, it is possibile to perform all of the analyser’s functions, and easily switch from the free measurement mode to the official exhaust test.

The AGS-688 comes with 6 backlighted LCD units, where test data are displayed.At the end of the exhaust gas test, it is possible to directly print the test results, or send them to a PC connected to the gas analyser.Connections to power supply, to RPM and temperature probes (with cable or wireless) to an external PC (via cable or wireless), are also present on the rear of the device.

AGS-688 OPERATING MODES

AGS-688: MORE INFORMATIONS ON WWW.BRAINBEE.COM

GAS ANALySER used to measure gas concentrations in the exhaust of petrol engines.

It can be used both for exhaust check in FORiodic mandatory tests and for ordinary service and maintenance operations on petrol engines.

AGS-688EXHAUST GAS ANALYSER

The AGS-688 was designed as a basic exhaust gas analyser; nevertheless, its wide range of optional accessories allows for a rich set of additional functions: • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT-

300.• By adding a radio module in AGS-688 expansion slot it is possible to connect the wireless MGT-300/R RPM meter.• It is possible AGS-688 to connect to a PC via RS232, USB or with a BT-100 Bluetooth ® module.• AGS-688 allows for connection to the smokemeter through the omniBUS port: in this case the analyser behaves like a

terminal to the smokemeter, where opacity of diesel exhaust can be displayed.

CO................................................................. 0 ÷ 9.99 %vol Res. 0.01 CO2............................................................... 0 ÷ 19.9 %vol Res. 0.1 HC HEXANE................................................... 0 ÷ 9999 ppmvol Res. 1 02.................................................................. 0 ÷ 25 %vol Res. 0.01 NoX................................................................ 0 ÷ 5000 ppmvol Res. 1 Lambda........................................................... 0.5 ÷ 5 Res. 0.001 RPM (INDUCTIVE/CAPACITIVE CLAMP)............. 300 ÷ 9990 RPM Res. 10 OIL TEMPERATURE........................................... 20 ÷ 150 °C Res. 1

AGS-688 PLUS FEATURES

MEASURING RANGE:

ACCESSORIESCODE DESCRIPTION1010750037XX TRO-050 TROLLEY

1010750038XX TRO-060 TROLLEY

1010750081XX TRO-220 TROLLEY

1010750063XX COVER TRO-220

1010750072XX LONG COVER TRO-220

1010750071XX COVER TRO-050/TRO-060

1010750083XX TRO-8250 MENSOLA TRO-220

1010750068XX TRO-8700 SUPPORT MGT-300 TRO-220/TRO-060/TRO-050

1010750067XX TRO-8795 PROBE HOLDER TRO-220/TRO-060/TRO-050

1010750077XX TRO-8830 SUPPORT TRO 060

1010750078XX TRO-8840 SUPPORT TRO 060

AGS-690 OPA-100 OPA-300 MGT-300AGS-688AGS-200

Page 4: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

4

The operating principle is based on the measurement of the absorption degree by infrared rays of gases which are present in the sample during the analysis. AGS-690 – thanks to its high accuracy technology – is able to assess absorption on the several frequency bands of the components - CO, CO2, HC – thus obtaining the associated concentration values. Concentrations of Oxygen and NO (optional) are measured by electrochemical sensors.Les mesures des concentrations d’Oxygène et NO (en option) sont relevées par des capteurs électrochimiques.

AGS-690 OFORATION MODE

AGS-690: MORE INFORMATIONS ON WWW.BRAINBEE.COM

Essential and user-friendly GAS ANALySER.

AGS-690 can be used for both exhaust check in mandatory inspections and for routine service and repair operations on vehicles.

AGS-690EXHAUST GAS ANALYSER

The completely new WATER SEPARATOR GROuP is injection moulded, in order to reduce the gas path’s length and maintenance times.

The separation filter consists of two sections: a mechanical filter and a coalescent (condensation) one.A single axis, dual-head pump allows for continuous removal of the water which condenses into the separator.

AGS-690 has exhaust gas and fresh air (autozero) inputs, and also a dedicated inlet for calibration with reference gases.

PNEUMATIC UNIT

CO................................................................. 0 ÷ 9.99 %vol Res. 0.01 CO2............................................................... 0 ÷ 19.9 %vol Res. 0.1 HC HEXANE................................................... 0 ÷ 9999 ppmvol Res. 1 02.................................................................. 0 ÷ 25 %vol Res. 0.01 NoX................................................................ 0 ÷ 5000 ppmvol Res. 1 Lambda........................................................... 0.5 ÷ 5 Res. 0.001 RPM (INDUCTIVE/CAPACITIVE CLAMP)............. 300 ÷ 9990 RPM Res. 10 OIL TEMPERATURE........................................... 20 ÷ 150 °C Res. 1

MEASURING RANGE:

EMISSION CONTROL

ACCESSORIES

CODE DESCRIPTION1010100002XX PSI-20 POWER SUPPLIER12V

1010100014XX PSI-50USB POWER SUPPLIER 13,5V@150W RAL7042

1010100016XX PSI-40 POWER SUPPLIER 12V@40W FOR AGS-688/AGS-690

1010100017XX PSI-51 POWER SUPPLIER 13,5V@150W FOR KOMBI

1010700096XX PSI-70 POWER SUPPLIER BLUETOOTH

1010700025XX OMNI-010 CABLE COMM./POWER SUPP. 0.4M

1010700065XX OMNI-011 CABLE COMM./POWER SUPP. 0.75M

1010700026XX OMNI-015 CABLE COMM./POWER SUPP. 2M

1010700027XX OMNI-020 CABLE COMM./POWER SUPP. 4M

1010700028XX OMNI-030 CABLE COMM./POWER SUPP. 6M

1010700135XX OMNI-050 POWER SUPP. CABLE AGS-688/AGS-690 2M

AGS-690 OPA-100 OPA-300 MGT-300AGS-688AGS-200

Page 5: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

5

OMNIBUS 800, the specific proprietary software developed by Brain Bee, allows for the management, with OPA-100, of different vehicle’s diagnostic and maintenance operations.

In compliance with the ministerial decree DM/628 and subsequent circulars, OPA-100 allows to perform the official test during the overhaul procedure.

Conforms to the MCTCNET communication protocolMetrological books coming with the tool

• ISO 11614• DM 628/96 and following circular letters• AU 4 (Germany)• MOT (England)• Austria • PCT-Gosstandart of Russia (Russia)

• BRML (Rumania)• OMH (Hungary)• Bulgaria• CEM (Spain)• Czech Rep • ARAI (India)

OPA-100 OPERATION MODE

OPA-100: MORE INFO ON WWW.BRAINBEE.COM

SMOkEMETER MODuLE to be connected to the serial port of any personal Computer

The small size and the 12V dc power supply allows using it as portable tool wherever required.

OPA-100SMOKEMETER FOR DIESEL ENGINES

OPACITY....................................................... 0 ÷ 99.9 % Res. 0.1 OPACITY....................................................... 0 ÷ 9.99 m-1 Res. 0.01 RPM counter.................................................. 300 ÷ 9990 rpm Res. 10 OIL TEMP...................................................... 20 ÷ 150 °C Res. 1 SMOKE TEMP............................................... 20 ÷ 400 °C Res. 1

MEASURE RANGE:

HOMOLOGATIONS

ACCESSORIES

CODE DESCRIPTION1010700136XX OMNI-060 POWER SUPP. CABLE AGS-688/AGS-690 6M

1010700030XX IF-010 SERIAL CONN. CABLE OPA/AGS-PC

1010700139XX IF-021 SERIAL CONN. CABLE MGT -> AGS-688/AGS-690 6M

1010700029XX IF-030 SERIAL CONN. CABLE PSI-PC 2M

1010700034XX ST-020 TEMP. PROBE OPA/AGS 6M

1010700134XX ST-050 SON.TEMP. -> AGS-688/AGS-690/OPA-300 6M

1010500004XX RPM-010 CABLE AGS-MOTO

1010400002XX RPM-020 CABLE OPA-PIEZO 6M

1010400013XX RPM-030 CABLE OPA-300 -> PIEZO 6M

1010400003XX TSD-010 CABLE FOR PIEZO 6MM

1010400004XX CA-020 CABLE OPA/AGS/BATT.

AGS-690 OPA-100 OPA-300 MGT-300AGS-688AGS-200

Page 6: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

6

Like other tools of the line, the OPA-300 opacimeter can be integrated in the different BRAIN BEE emissions control configurations, providing the end user with his own control station to meet his every requirement.

It can also be integrated in existing stations (on a Brain Bee trolley) demonstrating that restyling will not affect the performance of stations of those already working with Brain Bee tools.

In accordance with Decreto DM/628 and successive circulars, OPA-300 enables you to carry out the official test in the vehicle inspection procedure.

Conforms to the MCTCNET communication protocol

GUARANTEED MODULARITY

OPA-300: MORE INFORMATIONS ON WWW.BRAINBEE.COM

OPA-300 is the latest OPACIMETER MODuLE in the family of gas and fume analysis and control tools.

Easy to use and designed to ensure operational flexibility, OPA-300 is linked to the normal serial port of any PC (RS232 or RS485) and using the OMNIBUS800 proprietary software included, also guides the most inexpert operatore in his fume control operations.

OPA-300OPACIMETER FOR DIESEL ENGINES

OPACITY....................................................... 0 ÷ 99.9 % Res. 0.1 OPACITY....................................................... 0 ÷ 9.99 m-1 Res. 0.01 RPM counter.................................................. 300 ÷ 9990 rpm Res. 10 OIL TEMP...................................................... 20 ÷ 150 °C Res. 1 SMOKE TEMP............................................... 20 ÷ 400 °C Res. 1

MEASURE RANGE:

OFFICIAL VEHICLE INSPECTION TESTS

EMISSION CONTROL

ACCESSORIES

CODE DESCRIPTION1010500001XX NOX-010 SENSOR NO FOR AGS

1010500006XX CPI-020 INDUCTION CLAMP FOR AGS 2,5MT

1010500009XX CPI-030 INDUCTION CLAMP FOR AGS-688/AGS-690 2,5MT

1010700077XX SCU-900

1020500025XX SGM-010 MOTORCYCLE GAS PROBE

1010500008XX AQUASTOP FOR ANALIZERS R1/8

1021020009XX EOBD-300

1010601134XX BT-100 KIT BLUETOOTH

1010601163XX BT-100USB KIT BLUETOOTH

1010601137XX BT-200 KIT 2 BT100+CABLE BT011

AGS-690 OPA-100 OPA-300 MGT-300AGS-688AGS-200

Page 7: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

7

MGT-300/R, radio version, enables totally automatic wireless connection to all BRAIN BEE analysers and opacimeters.

It can also be combined with analysers of other brands by means of a special accessory (MGT-310)

Designed in conformity with Decreto DM/628 and successive circulars, it can be used alongside Brain Bee tools in official vehicle inspection tests.

MGT-300MGT-300 ST - without sensorMGT-300 R - via radioMGT-300 BLuE - bluetooth

WIRELESS, WHERE APPROPRIATE

MGT-300: MORE INFORMATIONS ON WWW.BRAINBEE.COM

Brain Bee’s REv COuNTER, which detects in a simple but extremely precise way the number of revs on all vehicles, both petrol and diesel.

The sophisticated software that drives it and the combined use of several acquisition systems mean that the MGT-300 covers almost all vehicles on the road.

MGT-300UNIVERSAL REV COUNTER FOR PETROL AND DIESEL ENGINES

REVS.............................................................. 200 ÷ 19990 rpm Res. 10TEMPERATURE.............................................. 0 ÷ 200 °C Res. 1

MEASURE RANGE:

OFFICIAL VEHICLE INSPECTION TESTS

AVAILABLE MODEL:

ACCESSORIES

CODE DESCRIPTION1010700142XX BT-022 SERIAL CONN. CABLE BT-100 -> AGS-688/AGS-690

1010601138XX BT-210 CABLE BT100<>AGS/OPA

1010601139XX BT-220 CABLE BT100<>PSI50/450

1010601141XX BT-240 CABLE KIT BT-PROG

AGS-690 OPA-100 OPA-300 MGT-300AGS-688AGS-200

Page 8: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

BRAIN BEE SpAvia Quasimodo, 4/A43126 PARMA - ITALYtel +39 0521 954411fax +39 0521 [email protected]

BRAIN BEE IBÉRICA S.A.Carrer de Saturn, 3308228 TERRASSA (BCN) - SPAINtel +34 93 731 3802fax +34 93 786 [email protected]

BRAIN BEE ASIA Pte Ltd36, Carpenter street059915 SINGAPOREtel +62 818946471 +65 [email protected]

BRAIN BEE ENGINEERING Srlvia Quasimodo, 443126 PARMA - ITALY

ÎCS “BRAIN BEE ENGINEERING GROUP” SrlStr. Academiei, 11/2 - MD. Chisinau 2028REPUBLICA MOLDOVA

TECHMESS ELEKTRONIK GMBHmember of Brain Bee GroupGewerbestr. 10-1678594 GUNNINGEN - GERMANYtel +49 7424 982320fax +49 7424 [email protected]

Brain Bee S.p.A. Via Quasimodo, 4/A - 43126 Parma - Italia - Tel. +39.0521.954411 - Fax +39.0521.954490 - [email protected] - www.brainbee.com Prog

etto

real

izzat

o in

col

labo

razio

ne c

on

COD.

8410

9009

1200

Page 9: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

TECHNICAL DATA

gAS ANALYSERS MEASURING BENCH AMB2 Sensors AMB2 Sensors AMB2 Sensors

MEASURING GAS SUCTION 4 l/min. 4 l/min. 4 l/min.

CONDENSED WATER PURGE Automatic and continuous Automatic and continuous Automatic and continuous

TIGHTNESS TEST Semiautomatic Semiautomatic Semiautomatic

FLOW CONTROL automatic automatic with minimum flow alarm

automatic with minimum flow alarm

CONTROL OF SPENT O2 SENSOR automatic (< 5mV) automatic (< 5mV) automatic (< 5mV)

PROTECTIVE FILTERS FOR GAS/WATER PUMP HEADS,

internal externally mounted for easy ser-vice, without removal of official seals

externally mounted for easy ser-vice, without removal of official seals

AUTOMATIC COMPENSATION OF AMBIENT PRESSURE

850 ÷ 1060 KPa 850 ÷ 1060 KPa 850 ÷ 1060 KPa

CALIBRATION with sample gas bottle with sample gas bottle with sample gas bottle

AUTOZERO automatic automatic automatic

HEATING TIME TO 20 °C 10 min. max 10 min. max 10 min. max

CO, CO2 E HC RESPONSE TIME < 10 sec. < 10 sec. < 10 sec.

O2 RESPONSE TIME < 60 sec. < 60 sec. < 60 sec.

PRINTER no Integrated 24-column ethermal printer

no

DISPLAY no 6 backlighted LCD units no

CONNECTIONS RPM reading via inductive or capacitive clamp

RPM reading via inductive or capacitive clamp

RPM reading via inductive or capacitive clamp

PT100 (DIN43760) oil tempera-ture probe input

PT100 (DIN43760) oil tempera-ture probe input

PT100 (DIN43760) oil tempera-ture probe input

RPM/oil temperature reading via 433 MHz radio receiver

RPM/oil temperature reading via 433 MHz radio receiver (optional)

RPM/oil temperature reading via 433 MHz radio receiver (optional)

Serial network link RS 485 Serial connections: PC via USB B (slave mode); PC via RS-232 (9600,N, 8,1); PC via RS-485 network (9600,N, 8,1)

Serial connections: PC via USB B (slave mode); PC via RS-232 (9600,N, 8,1); PC via RS-485 network (9600,N, 8,1)

Software programming/update via RS-232

Software programming/update via RS-232

Software programming/update via RS-232

Combi mode available with OPA-100 smokemeter

POWER SUPPLY 12 VDC typ (11-15VDC) 12 VDC typ (11-15VDC) 12 VDC typ (11-15VDC)

POWER CONSUMPTION 1.5A 1.5A DC (3A when printing) 1.5A

OPERATING TEMPERATURE 5 ÷ 40°C 5 ÷ 40°C 5 ÷ 40°C

DIMENSIONS 220 x 140 x 430 mm 434 x 190 x 291 mm 360 x 280 x 288 mm

WEIGHT 5Kg 5Kg 5Kg

AGS-690AGS-688AGS-200

Page 10: EMISSION CONTROL - dijagnostika-vozila.rs · • An integrated RPM meter is available, which can support any of these choices: induction clamp, capacitive clamp or MGT- ... The completely

TECHNICAL DATA

SMOKEMETERS

LIGHT SOURCE Green LED Green LED

LIGHT RECEIVER Photodiode Photodiode

MEASUREMENT CHAMBER PRESSURE CONTROL automatic automatic

STABILISING OF MEASURING CHAMBER AT 90°C yes yes

GLASSES CLEANING SYSTEM AUTOMATIC CONTROL automatic automatic

AUTOZERO automatic automatic

HEATING TIME TO 20 °C 10 minutes 10 minutes

RPM AND TEMPERATURE RECEPTION via cable or radio via cable or radio

CONNECTIONS RS 232 serial connection RS 232 serial connection

RS 485 network serial connection RS 485 network serial connection

POWER SUPPLY 12 VDC typ (11-15VDC) 12 VDC typ (11-15VDC)

POWER CONSUMPTION 1A DC, 5A DC with heating ON 1A DC, 5A DC with heating ON

OPERATING TEMPERATURE 0 ÷ 40°C 0 ÷ 40°C

DIMENSIONS 200 x140 x 430 mm 360 x 280 x 288 mm

WEIGHT 5 Kg 5 Kg

OPA-300OPA-100

RPM

VIEWER 4-figure display

POWER SUPPLY from 10 to 16 Vdc ; from 10 to 34 Vdc (if high voltage)

INPUTS magnetic sensor;

PT100 temperature sensor

RPM and temperature recep-tion through EOBD port (with EOBD-300 accessory)

Terminal for induction clip (for link to any gas analyser)

OUTPUTS Impulse output (for direct link to gas analyser and opacimeters)

SELECTION Number of cylinders;

Number of strokes

COMMUNICATIONS Data transmission via serial inter-face RS232/RS485

Data transmission via Radio interface (if MGT-300/R)

DIMENSIONS 200 x 100 x 45 mm

WEIGHT 500g

MGT-300