EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 10-03 Revisions: 8-14-02 - Changed EM170/240HZ dwg 3-11-03 - Changed HZ dwg to field convertible 5-02-03 EM360 coil area to 27.00 ft sq 5-12-03 Guide Specification updated 7-01-03 Removed EM051 and EM061 9-4-03 Reinstated EM051 and EM061 9-11-03 Updated HZ drawing 9-22-03 EM012 WL COP changed 10-21-03 Corrected EM144-360 filter rack dimensions

EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

EMIP60 ISO

EM Series, Inch Pounds - 60 HzEM007-360 (iso)

Spec GuidesDrawings

Spec SheetsExtended Range Ratings

Low Temp Heating

Rev 10-03Revisions:

8-14-02 - Changed EM170/240HZ dwg3-11-03 - Changed HZ dwg to field convertible

5-02-03 EM360 coil area to 27.00 ft sq5-12-03 Guide Specification updated

7-01-03 Removed EM051 and EM0619-4-03 Reinstated EM051 and EM061

9-11-03 Updated HZ drawing9-22-03 EM012 WL COP changed

10-21-03 Corrected EM144-360 filter rack dimensions

Page 2: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

GENERALUnits shall be performance certified to ISO standard13256-1 for Water Loop Heat Pump, Ground Water Heat Pump andGround Loop Heat Pump applications. Units intended for use onground loop applications shall have an optional extended range pack-age installed. Units shall be Underwriter Laboratories (UL and cUL)listed for safety on all models. Each unit shall be run tested at thefactory. Each unit shall be pallet mounted and stretch wrapped.

The units shall be warranted by the manufacturer against defects inmaterials and workmanship for a period of one year on all parts,and 5 years on the compressor.

The units shall be designed to operate with entering fluid tempera-tures between 50OF (10OC) and 100OF (38OC) in cooling and be-tween 50OF (10OC) and 80OF (27OC) in heating. With the optionalfactory installed extended range package units shall operate withentering fluid temperatures between 500F (10OC) and 110OF (43.3OC)in cooling and between 25OF (-3.9OC) and 80OF (27OC) inheating.

CASING & CABINETThe cabinet shall be fabricated from heavy-gauge steel finishedwith Galvalume® plus, an aluminum-zinc alloy with a clear acryliccoating for additional corrosion protection. The interior shall beinsulated with ½” (12.7mm) thick, multi density, coated, glass fi-ber. All units shall allow sufficient service access to replace thecompressor without unit removal. One blower and two compres-sor compartment access panels shall be removable with supply andreturn ductwork in place. A duct collar shall be provided on thesupply air opening. A 2" (50.8mm) return air filter rack/duct collarwith 1" (25.4mm) thick filters shall be provided with each unit.The units shall have an insulated divider panel between the airhandling section and the compressor section to minimize the trans-mission of compressor noise, and to permit service testing withoutair bypass. Units shall have a stainless steel condensate drain pan.

REFRIGERATION CIRCUITSAll units shall contain a sealed refrigerant circuit including a her-metic compressor, capillary tube metering device with strainer orbalance port expansion valve, finned tube air-to-refrigerant heatexchanger, refrigerant reversing valve and service ports. Compres-sor shall be high efficiency, designed for heat pump duty, internallyspring isolated (if reciprocating type) for maximum sound attenua-tion and mounted on rubber vibration isolators. Compressor mo-tors shall be equipped with overload protection. Refrigerant re-versing valves shall be pilot operated sliding piston type with re-placeable encapsulated magnetic coils energized only during thecooling cycle. The finned tube coil shall be constructed of lancedaluminum fins not exceeding fourteen fins per inch bonded to rifledcopper tubes in a staggered pattern not less than three rows deepand have a 450 PSIG (3100 kPa) working pressure. Coils shall beepoxy coated using an electro coating process for protection againstmost airbourn chemicals.The coil shall have aluminum end sheets.The coaxial water-to-refrigerant heat exchanger shall be constructedof a convoluted copper (optional cupronickel) inner tube and steelouter tube with a designed refrigerant working pressure of 450

PSIG (3100 kPa) and designed water side working pressure of noless than 400 PSIG (2750 kPa).

EXTENDED RANGE PACKAGEAn optional extended range package shall include a bi-flow bal-anced port expansion valve metering device in place of capillarytubes and insulated water to refrigerant heat exchanger.

FAN MOTOR & ASSEMBLYThe fan shall be direct drive centrifugal forward curved type with adynamically balanced wheel. The housing and wheel shall be de-signed for quiet low velocity operation. The fan housing shall beremovable from the unit without disconnecting the supply airductwork for servicing of the fan motor. The fan motor shall bethree speed PSC type for direct drive units and single speed for beltdrive units. The motor shall be permanently lubricated and havethermal overload protection.

ELECTRICALControls and safety devices will be factory wired and mountedwithin the unit. Controls shall include fan relay, compressorcontactor, 24V transformer, reversing valve coil and solid statelockout controller (UPM) The UPM controller shall include thefollowing features: Anti-short cycle time delay, random start, brownout/surge/power interruption protection, 90 second low pressure switchbypass timer, shutdown on high or low refrigerant pressure safetyswitch inputs, shutdown for the optional freezestat or high levelcondensate sensors, 24 VAC alarm output for remote fault indication,unit reset at thermostat or disconnect, ability to defeat time delays forservicing and automatic intelligent reset. The UPM shall automati-cally reset after a safety shut down and restart the unit, if the cause ofthe shut down no longer exists, after the anti-short cycle and randomstart timers expire. Should a fault re-occur within 10 minutes afterreset, then a permanent lockout will occur. A light emitting diode(LED) shall annunciate the following alarms: high refrigerant pressure,low refrigerant pressure, low water temperature and a high level ofcondensate in the drain pan (when equipped with the optional lowwater temperature and high level condensate sensors). The LED willdisplay each fault condition as soon as the fault occurs. If a permanentlockout occurs, then the fault LED will display the type of fault untilthe unit is reset.Safety devices include a low pressure cutout set a 20 PSIG (140kPa) for loss of charge protection (freezestat and/or high dischargegas temperature sensor is not acceptable) and a high pressure cut-out control set at 380 PSIG (2600 kPa). An optional energy man-agement relay that allows unit control by an external source shall befactory installed.A terminal block with screw terminals shall be provided for controlwiring.

PIPINGSupply, return water and condensate drain connections shall bebrass female pipe thread fittings and mounted flush to cabinet exte-rior with optional stainless steel, Braided hose kit with swivelconnectors.

EMSPECS.P65 REV: 9-03

GUIDESPECIFICATIONS

EM Series 1/2-6 Ton

Page 3: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

GENERALUnits shall be performance certif ied to ISO standard13256-1 for Water Loop Heat Pump, Ground Water Heat Pumpand Ground Loop Heat Pump applications for units up to 10 tons.Units intended for use on ground loop applications shall have anoptional extended range package installed which consists of an in-sulated water to refrigerant heat exchanger. Units shall be Under-writer Laboratories (UL and cUL) listed for safety on all models.Each unit shall be run tested at the factory. Each unit shall be palletmounted and stretch wrapped.

The units shall be warranted by the manufacturer against defects inmaterials and workmanship for a period of one year on all parts,and 5 years on the compressor.

The units shall be designed to operate with entering fluid tempera-tures between 50oF (10oC) and 100oF (38oC) in cooling and be-tween 50oF (10oC) and 80oF (27oC) in heating. With the optionalfactory installed extended range package units shall operate withentering fluid temperatures between 50oF (10oC) and 110oF (43.3oC)in cooling and between 25oF (-3.9oC) and 80oF (27oC) inheating.

CASING & CABINETThe cabinet shall be fabricated from heavy-gauge galvanized steel.The interior shall be insulated with ½” (12.7mm) thick, multi den-sity, coated, glass fiber. All units shall allow sufficient service ac-cess to replace the compressors without unit removal. Two blowerand two compressor compartment access panels shall be remov-able with supply and return ductwork in place. A duct collar shallbe provided on the supply air opening of all vertical units. A 2"(50.8mm) return air filter rack/duct collar with 1" (25.4mm) thickfilters shall be provided with each unit. Vertical units shall have aninsulated divider panel between the air handling section and thecompressor section to minimize the transmission of compressornoise, and to permit operational service testing without air bypass.Units shall have stainless steel condensate drain pan(s).

REFRIGERATION CIRCUITSAll units shall contain sealed refrigerant circuits including her-metic compressors, thermal expansion valve metering devices,finned tube air-to-refrigerant heat exchangers, refrigerant reversingvalves and service ports. Compressors shall be high efficiency,designed for heat pump duty, internally spring isolated (except forscroll type compressors) for maximum sound attenuation andmounted on rubber vibration isolators. Compressor motors shallbe equipped with overload protection. Refrigerant reversing valvesshall be pilot operated sl iding piston type withreplaceable encapsulated magnetic coils energized only during thecooling cycle. The finned tube coil shall be constructed of lancedaluminum fins not exceeding fourteen fins per inch bonded to rifledcopper tubes in a staggered pattern not less than three rows deepand have a 450 PSIG (3100 kPa) working pressure. Coils shall beepoxy coated using an electro coating process for protection againstmost airbourn chemicals.Coils shall have aluminum end sheets. The

coaxial water-to-refrigerant heat exchangers shall be constructed ofa convoluted copper (optional cupro-nickel) inner tube and steelouter tube with a designed refrigerant working pressure of 450PSIG (3100 kPa) and a designed water side working pressure of noless than 400 PSIG (2750 kPa).

FAN MOTOR & ASSEMBLY(S)The fan(s) shall be belt driven DWDI forward curved type withdynamically balanced wheel(s). The housing(s) and wheel(s) shallbe designed for quiet low velocity operation. The fan housing(s)shall be removable from the unit without disconnecting the supplyair ductwork for servicing of the fan motor(s). The fan motor(s)shall be 1725 or 3450 RPM 56 frame sealed ball bearing type. Themotor(s) shall be permanently lubricated and have thermal over-load protection.

ELECTRICALControls and safety devices will be factory wired and mountedwithin the unit . Controls shall include fan relay(s),compressor contactors, 24V transformer, reversing valve coils anda solid state lock-out control circuit (UPM). The UPM controllershall include the following features: Anti-short cycle time delay,random start, interstage delay, brown out/surge/power interruptionprotection, 90 second low pressure switch bypass timer, shutdown onhigh or low refrigerant pressure safety switch inputs, shutdown forthe optional freezestat or high level condensate sensors, 24 VAC alarmoutput for remote fault indication, unit reset at thermostat or discon-nect, ability to defeat time delays for servicing, time delay betweenstages and automatic intelligent reset. The UPM shall automaticallyreset after a safety shut down and restart the unit, if the cause of theshut down no longer exists, after the anti-short cycle and random starttimers expire. Should a fault re-occur within 10 minutes after reset,then a permanent lockout will occur. A light emitting diode (LED) shallannunciate the following alarms for each refrigerant circuit: high refrig-erant pressure, low refrigerant pressure, low water temperature and ahigh level of condensate in the drain pan (when equipped with theoptional low water temperature and high level condensate sensors).The LED will display each fault condition as soon as the fault occurs.If a permanent lockout occurs, then the fault LED will display thetype of fault until the unit is reset. Safety devices include a lowpressure cutout set at 20 PSIG (140 kPa) for loss of charge protec-tion (a freezestat used for loss of charge protection is not accept-able) and a high pressure cutout control set at 380 PSIG (2600kPa). An optional energy management relay to allow unit controlby an external source shall be factory installed.

PIPINGSupply, return water and condensate drain connections shall becopper or brass female pipe thread fittings and mounted flush tocabinet exterior.

LEMSPECS.P65 Rev: 9-03

GUIDESPECIFICATIONS

EM Series 6-30 Large Commercial

Page 4: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

AB

CD

EF

GH

JK

MN

PQ

Con

dens

erR

ecom

men

ded

MO

DEL

R/A

Duct

R/A

Duct

Filter

Rac

kW

ater

Rep

lace

men

tW

idth

Dep

thH

eigh

tFlg

Widt

hFlg

Heig

htH

eigh

tC

onne

ctio

nsNo

mina

l Filte

r Size

EM

007,

009

19.0

019

.00

24.2

511

.75

7.75

3.50

8.25

2.38

4.88

7.38

15.0

08.

0010

.00

8.25

3/4"

F.P

.T.

10 X

16

X 1

EM01

219

.00

19.0

024

.25

11.7

57.

753.

509.

752.

384.

887.

3815

.00

8.00

10.0

05.

003/

4" F

.P.T

.10

X 1

6 X

1EM

015

21.5

021

.50

32.2

511

.75

9.75

5.88

7.88

2.38

7.38

13.2

517

.50

14.0

016

.00

7.88

3/4"

F.P

.T.

16 X

20

X 1

EM01

821

.50

21.5

032

.25

13.7

511

.75

2.75

6.75

2.38

7.38

13.2

517

.50

14.0

016

.00

6.75

3/4"

F.P

.T.

16 X

20

X 1

EM02

421

.50

21.5

036

.25

13.7

511

.75

2.75

6.75

2.38

7.38

12.5

017

.50

16.0

018

.00

6.75

3/4"

F.P

.T.

18 X

20

X 1

EM02

821

.50

21.5

039

.25

15.7

513

.75

2.75

5.75

2.38

7.38

12.5

017

.50

18.0

020

.00

5.75

3/4"

F.P

.T.

20 X

20

X 1

EM03

121

.50

21.5

039

.25

15.7

513

.75

2.75

5.75

2.38

7.38

13.5

017

.50

18.0

020

.00

5.75

3/4"

F.P

.T.

20 X

20

X 1

EM03

621

.50

26.0

043

.25

15.7

515

.75

4.75

5.50

2.38

8.38

14.7

522

.00

22.0

024

.00

5.50

3/4"

F.P

.T.

24 X

24

X 1

EM04

121

.50

21.5

039

.25

15.7

513

.75

3.00

5.50

2.38

8.38

14.7

517

.50

18.0

020

.00

5.50

3/4"

F.P

.T.

20 X

20

X 1

EM04

221

.50

26.0

043

.25

15.7

515

.75

4.75

5.50

2.38

8.38

14.7

522

.00

22.0

024

.00

5.50

3/4"

F.P

.T.

24 X

24

X 1

EM04

824

.00

32.5

045

.25

15.7

515

.75

10.7

56.

502.

638.

3814

.75

28.0

022

.00

24.0

06.

501"

F.P

.T.

24 X

30

X 1

EM05

126

.00

26.0

043

.25

15.7

515

.75

5.13

5.13

2.38

6.25

9.75

22.0

028

.00

30.0

05.

131"

F.P

.T.

24 X

30

X 1

EM06

024

.00

32.5

045

.25

17.7

517

.75

10.0

05.

133.

009.

6316

.63

28.0

022

.00

24.0

05.

131"

F.P

.T.

24 X

30

X 1

EM06

126

.00

26.0

043

.25

17.7

517

.75

4.13

4.13

2.38

6.25

9.75

22.0

028

.00

30.0

05.

131"

F.P

.T.

24 X

30

X 1

EM07

026

.00

33.2

558

.25

17.7

517

.75

9.50

6.50

3.38

8.38

17.3

828

.00

30.0

032

.00

6.50

1" F

.P.T

.16

X 3

0 X

1 (2

)

Left

Han

dR

etur

n(F

LT)

EMVT

GD

IP F

LA.P

65R

EV: 0

9-03

NO

TES:

All

dim

ensi

ons

with

in +

/- 0.

125"

.A

ll co

nden

sate

dra

in c

onne

ctio

ns a

re 3

/4"

FPT.

EM

051

and

061

only

ava

ilabl

e in

ver

tical

con

figur

atio

n.Sp

ecifi

catio

ns s

ubje

ct to

cha

nge

with

out n

otic

e.

Rig

ht H

and

Ret

urn

(FR

T)

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

EM S

erie

s EM

Ser

ies

EM S

erie

s EM

Ser

ies

EM S

erie

s VVVV V e

rererer ertic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

s

Page 5: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

AB

CD

EF

GH

JK

MN

PQ

RT

Con

dens

erRe

comm

ende

dM

OD

ELR/

A Du

ctFil

ter R

ack

R/A

Duct

Wat

erRe

place

ment

Wid

thD

epth

Hei

ght

Flg W

idth

Hei

ght

Flg H

eight

Conn

ectio

nsNo

m. Fi

lter S

izeE

M00

7, 0

0919

.00

31.0

011

.25

2.00

15.0

014

.00

2.38

7.38

2.25

11.7

51.

257.

752.

251.

8810

.00

8.00

3/4"

F.P

.T.

10 X

16

X 1

EM01

219

.00

31.0

011

.25

2.00

15.0

014

.00

2.38

7.38

2.50

11.7

51.

257.

752.

251.

8810

.00

8.00

3/4"

F.P

.T.

10 X

16

X 1

EM01

521

.50

43.0

017

.00

2.00

17.5

023

.50

2.38

13.2

54.

0011

.75

1.25

9.75

2.25

1.88

16.0

014

.00

3/4"

F.P

.T.

16 X

20

X 1

EM01

821

.50

43.0

017

.00

2.00

17.5

023

.50

2.38

13.2

53.

5011

.75

1.25

13.7

53.

501.

7516

.00

14.0

03/

4" F

.P.T

.16

X 2

0 X

1EM

024

21.5

043

.00

19.0

02.

0017

.50

23.5

02.

3812

.50

3.25

11.7

53.

2513

.75

3.25

1.75

18.0

016

.00

3/4"

F.P

.T.

18 X

20

X 1

EM02

822

.00

45.0

019

.00

2.00

19.5

023

.50

2.38

12.5

02.

5013

.75

1.50

15.7

52.

501.

5018

.00

16.0

03/

4" F

.P.T

.18

X 2

0 X

1EM

031

22.0

045

.00

19.0

02.

0019

.50

23.5

02.

3813

.50

2.50

13.7

51.

5015

.75

2.50

1.50

18.0

016

.00

3/4"

F.P

.T.

18 X

20

X 1

EM03

622

.00

54.5

019

.00

2.00

29.0

023

.50

2.38

14.7

52.

5013

.75

1.50

15.7

52.

501.

5018

.00

16.0

03/

4" F

.P.T

.18

X 3

0 X

1EM

041

21.5

043

.00

22.0

02.

0017

.50

23.5

02.

3814

.75

2.50

13.7

53.

0015

.75

3.25

3.00

20.0

018

.00

3/4"

F.P

.T.

20 X

20

X 1

EM04

222

.00

54.5

019

.00

2.00

29.0

023

.50

2.38

14.7

52.

5013

.75

1.50

15.7

52.

501.

5018

.00

16.0

03/

4" F

.P.T

.18

X 3

0 X

1EM

048

36.0

043

.00

21.0

02.

2533

.75

7.00

2.63

14.7

510

.13

15.7

52.

5015

.75

3.00

2.50

20.0

018

.00

1" F

.P.T

.18

X 20

X 1

(2)

EM06

036

.00

43.0

021

.00

2.25

33.7

57.

003.

0016

.63

10.1

315

.75

1.50

17.7

53.

251.

5020

.00

18.0

01"

F.P

.T.

18 X

20 X

1 (2

)EM

070

26.0

078

.00

21.5

02.

5044

.00

31.5

03.

1218

.50

2.75

17.7

52.

7517

.75

2.75

1.25

20.5

018

.50

1" F

.P.T

.20

X 24

X 1

(2)

EMH

ZDG

IP.P

65c

FH

P M

anuf

actu

ring

Com

pany

R

EV:9

-11-

03

NO

TES:

All

dim

ensi

ons

with

in +

/- 0.

125"

. A

ll co

nden

sate

dra

in c

onne

ctio

ns a

re 3

/4"

FPT.

Spec

ifica

tions

sub

ject

to c

hang

e w

ithou

t not

ice.

E

M01

5-07

0 ca

n be

fiel

dco

nver

ted

betw

een

end

blow

and

stra

ight

thro

ugh

supp

ly a

ir co

nfig

urat

ions

Rig

ht H

and

Ret

urn

Stra

ight

Thr

ough

(FR

S)

Rig

ht H

and

Ret

urn

End

Blo

w (F

RE

)

Left

Han

d R

etur

nE

nd B

low

(FLE

)Le

ft H

and

Ret

urn

Stra

ight

Thr

ough

(FLS

)

Left

Han

d R

etur

n(N

ote:

Mod

els

EM

048

& 0

60 L

eft H

and

Ret

urn

units

hav

e co

nden

ser

wat

erco

nnec

tions

on

the

front

righ

t and

ele

c-tri

cal k

nock

outs

on

the

front

left.

)

Rig

ht H

and

Ret

urn

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

EM S

erie

s Ho

rizon

tal D

imen

sion

sEM

Ser

ies

Horiz

onta

l Dim

ensi

ons

EM S

erie

s Ho

rizon

tal D

imen

sion

sEM

Ser

ies

Horiz

onta

l Dim

ensi

ons

EM S

erie

s Ho

rizon

tal D

imen

sion

s

Page 6: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

AB

CD

EF

GH

JK

MN

PC

onde

nser

Rec

omm

ende

dM

OD

ELB

low

erB

low

erR/

A Du

ctR/

A Du

ctFil

ter R

ack

Wat

erR

epla

cem

ent

Wid

thD

epth

Hei

ght

Ope

ning

Ope

ning

Flg W

idth

Flg H

eight

Hei

ght

Con

nect

ions

Nom

inal F

ilter S

izeE

M00

7, 0

0919

.00

19.0

024

.25

6.25

4.25

6.00

10.2

55.

0010

.00

10.2

515

.00

8.00

10.0

03/

4" F

.P.T

.10

X 1

6 X

1EM

012

19.0

019

.00

24.2

55.

254.

007.

0012

.38

5.00

10.0

07.

7515

.00

8.00

10.0

03/

4" F

.P.T

.10

X 1

6 X

1EM

015

21.5

021

.50

32.2

56.

254.

256.

5012

.00

5.88

16.7

512

.00

17.5

014

.00

16.0

03/

4" F

.P.T

.16

X 2

0 X

1EM

018

21.5

021

.50

32.2

59.

639.

258.

138.

005.

8816

.75

8.00

17.5

014

.00

16.0

03/

4" F

.P.T

.16

X 2

0 X

1EM

024

21.5

021

.50

36.2

59.

639.

258.

138.

005.

8816

.00

8.00

17.5

016

.00

18.0

03/

4" F

.P.T

.18

X 2

0 X

1EM

028

21.5

021

.50

39.2

59.

639.

258.

138.

005.

8816

.00

8.00

17.5

018

.00

20.0

03/

4" F

.P.T

.20

X 2

0 X

1EM

031

21.5

021

.50

39.2

59.

639.

258.

138.

004.

8816

.00

8.00

17.5

018

.00

20.0

03/

4" F

.P.T

.20

X 2

0 X

1EM

036

21.5

026

.00

43.2

510

.25

9.25

10.0

08.

754.

3816

.75

8.75

22.0

022

.00

24.0

03/

4" F

.P.T

.24

X 2

4 X

1EM

041

21.5

021

.50

39.2

510

.25

9.25

7.25

7.75

4.38

16.7

57.

7517

.50

18.0

020

.00

3/4"

F.P

.T.

20 X

20

X 1

EM04

221

.50

26.0

043

.25

10.2

59.

2510

.00

8.75

4.38

16.7

58.

7522

.00

22.0

024

.00

3/4"

F.P

.T.

24 X

24

X 1

EM04

824

.00

32.5

045

.25

11.7

510

.75

9.25

9.00

6.00

18.2

59.

0028

.00

22.0

024

.00

1" F

.P.T

.24

X 3

0 X

1EM

060

24.0

032

.50

45.2

512

.50

12.0

09.

008.

004.

2517

.75

8.00

28.0

022

.00

24.0

01"

F.P

.T.

24 X

30

X 1

EM07

026

.00

33.2

558

.25

12.0

012

.50

10.6

35.

003.

0018

.50

5.00

28.0

030

.00

32.0

01"

F.P

.T.

16 X

30

X 1

(2)

EMC

FDG

IP.P

65R

EV: 6

-28-

99

NO

TES:

All

dim

ensi

ons

with

in +

/- 0.

125"

.A

ll co

nden

sate

dra

in c

onne

ctio

ns a

re 3

/4"

FPT.

Spec

ifica

tions

sub

ject

to c

hang

e w

ithou

t not

ice.

Left

Han

dR

etur

n(F

LB)

Rig

htH

and

Ret

urn

(FR

B)

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

EM S

erie

s Co

unte

rflow

Dim

ensi

ons

EM S

erie

s Co

unte

rflow

Dim

ensi

ons

EM S

erie

s Co

unte

rflow

Dim

ensi

ons

EM S

erie

s Co

unte

rflow

Dim

ensi

ons

EM S

erie

s Co

unte

rflow

Dim

ensi

ons

Page 7: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Dim

ensi

ons

All

Dim

ensi

ons

+/- 0

.125

"

Dim

ensi

onM

odel

-072

-096

-120

-150

-180

Hei

ght

62.0

062

.00

62.0

066

.50

86.5

0W

idth

42.0

042

.00

42.0

042

.00

42.0

0D

epth

32.0

032

.00

32.0

032

.00

32.0

0

Con

dens

er C

onne

ctio

nsA

14.7

514

.75

15.0

015

.00

15.0

0B

8.50

8.50

9.00

9.00

9.00

C2.

752.

753.

003.

003.

00D

ia. (

FPT)

1.00

"1.

00"

1.50

"2.

00"

2.00

"

Ret

urn

Air

Ope

ning

D(D

uct F

lang

e)38

.00

38.0

038

.00

38.0

058

.00

E(F

ilter

Rac

k)40

.00

40.0

040

.00

40.0

060

.00

Rep

lace

men

t Filt

er S

ize

-072

thro

ugh

-150

20 x

34-

1/2

x 1

(2 p

er u

nit)

-180

30 x

34-

1/2

x 1

(2 p

er u

nit)

Serv

ice

Acc

ess

Pane

l #A

cces

s To

:1

Con

trols

, C

ompr

esso

rs,

Ref

riger

atio

n C

ompo

nent

s2

Blo

wer

& M

otor

3B

low

er

Fron

t R

etur

nSt

anda

rdB

low

erO

rient

atio

n

Opt

iona

lB

low

erO

rient

atio

n(9

79-0

32)

Not

es:

Con

dens

ate

conn

ectio

ns a

re 0

.75"

FP

T on

-072

thro

ugh

-120

and

1.2

5" F

PT

on -1

50 a

nd -1

80.

Due

to c

ontin

uing

res

earc

h an

d de

velo

pmen

t, sp

ecifi

catio

ns a

re s

ubje

ct to

cha

nge

with

out n

otic

e.EM

SVD

GIP

.P65

Rev

. 2-0

5-01

Top

Supp

ly(F

BT)

Fron

t Sup

ply

(FB

F)

Opt

iona

lB

low

erO

rient

atio

n(9

79-0

32)

Rea

r R

etur

nSt

anda

rdB

low

erO

rient

atio

n

Top

Supp

ly (F

FT)

Rea

r Sup

ply

(FFR

)

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

EM07

2-18

0 EM

072-

180

EM07

2-18

0 EM

072-

180

EM07

2-18

0 VVVV V e

rererer ertic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

sSi

ngle

Blo

wer

Lar

ge C

omm

erci

al U

nits

Page 8: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Dim

ensi

ons

All

Dim

ensi

ons

+/- 0

.125

"D

imen

sion

Mod

el-0

72-0

96-1

20-1

40H

eigh

t21

.50

21.5

021

.50

25.5

0W

idth

38.0

038

.00

38.0

042

.00

Dep

th78

.00

78.0

078

.00

82.0

0

Ret

urn

Air

Dim

ensi

ons

A2.

002.

002.

002.

00B

20.5

020

.50

20.5

024

.00

C18

.50

18.5

018

.50

22.0

0

Con

dens

er C

onne

ctio

nsE

26.2

526

.25

27.5

022

.50

F2.

752.

753.

382.

75G

37.5

037

.50

38.2

530

.75

H14

.50

19.2

516

.75

18.2

5D

iam

eter

1"FP

T1"

FPT

1.25

"FPT

1.50

"FPT

Supp

ly A

ir D

imen

sion

s (B

low

er O

utle

t)J

15.5

015

.50

12.5

018

.50

K13

.50

13.5

013

.50

16.0

0L

10.5

010

.50

5.25

14.0

0

Rep

lace

men

t Filt

er S

ize

072-

120

20 x

34-

1/2

x 1

(2 p

er u

nit)

140

24 x

34

x 1

(2 p

er u

nit)

Serv

ice

Acc

ess

Pane

l#A

cces

s To

:1

Con

trols

, C

ompr

esso

rs2

Blo

wer

& M

otor

3C

ompr

esso

rs,

Ref

riger

atio

n C

ompo

nent

s

Not

es:

All

cond

ensa

te c

onne

ctio

ns a

re 0

.75"

FP

T.D

ue to

con

tinui

ng r

esea

rch

and

deve

lopm

ent,

spec

ifica

tions

are

sub

ject

to c

hang

e w

ithou

t not

ice.

EMLH

DG

IP.P

65R

ev. 4

-01

072,

096

& 1

40 (-

SLS

Onl

y)12

0 (-S

LS O

nly)

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

EM07

2-14

0 Ho

rizon

tal D

imen

sions

EM07

2-14

0 Ho

rizon

tal D

imen

sions

EM07

2-14

0 Ho

rizon

tal D

imen

sions

EM07

2-14

0 Ho

rizon

tal D

imen

sions

EM07

2-14

0 Ho

rizon

tal D

imen

sions

Page 9: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Dim

ensi

ons

Con

dens

er C

onne

ctio

nsEM

170

1.50

"FPT

EM24

02.

00"F

PT

Rep

lace

men

t Filt

er S

ize

EM

170

24 x

34

x 1

(2)

EM

240

20 x

34-

1/2

x 1

(4)

Serv

ice

Acc

ess

Pane

l#A

cces

s To

:1

Con

trols

,C

ompr

esso

rs,

Ref

riger

atio

nC

ompo

nent

s2

Blo

wer

s &

Mot

ors

3C

ompr

esso

rs,

Ref

riger

atio

nC

ompo

nent

sN

otes

:A

ll di

men

sion

s +/

- 0.1

25".

All

cond

ensa

te c

onne

ctio

ns a

re 1

.25"

FP

T.D

ue to

con

tinui

ng r

esea

rch

and

deve

lopm

ent,

spec

ifica

tions

are

sub

ject

to c

hang

e w

ithou

t not

ice.

EM17

0240

HZI

P.P6

5R

ev.8

-02

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

EM17

0-24

0 Ho

rizon

tal D

imen

sion

sEM

170-

240

Horiz

onta

l Dim

ensi

ons

EM17

0-24

0 Ho

rizon

tal D

imen

sion

sEM

170-

240

Horiz

onta

l Dim

ensi

ons

EM17

0-24

0 Ho

rizon

tal D

imen

sion

s

EM24

0 S

LSC

ON

FIG

UR

ATIO

NO

NLY

EM17

0 S

LSC

ON

FIG

UR

ATIO

NO

NLY

Page 10: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

EM14

4-36

0 EM

144-

360

EM14

4-36

0 EM

144-

360

EM14

4-36

0 VVVV V e

rererer ertic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

stic

al D

imen

sion

sD

ual B

low

er L

arge

Com

mer

cial

Uni

ts

Dim

ensi

ons

All

Dim

ensi

ons

+/- 0

.125

"

Mod

elH

eigh

tA

BC

DE

144

62.0

017

.00

10.5

03.

0040

.00

38.0

016

862

.00

17.0

010

.50

3.00

40.0

038

.00

210

62.0

014

.75

8.50

2.75

40.0

038

.00

240

66.5

014

.75

8.75

2.75

40.0

038

.00

300

66.5

014

.75

8.75

2.75

40.0

038

.00

360

86.5

015

.00

9.00

3.50

60.0

058

.00

Mod

elC

onde

nser

Con

dens

ate

Con

nect

ion

Dra

inD

iam

eter

Dia

met

er14

41.

50"F

PT1.

25"F

PT16

81.

50"F

PT1.

25"F

PT21

02.

00"F

PT1.

25"F

PT24

02.

00"F

PT1.

25"F

PT30

02.

00"F

PT1.

25"F

PT36

02.

00"F

PT1.

25"F

PT

Rec

omm

ende

d R

epla

cem

ent

Filte

r Siz

e (N

omin

al)

20 x

34-

1/2

x 1

(4 p

er u

nit,

144-

300)

30 x

34-

1/2

x 1

(4 p

er u

nit,

360)

Serv

ice

Acc

ess

Pane

l #A

cces

s To

:1

Con

trols

, C

ompr

esso

rs,

Ref

riger

atio

n C

ompo

nent

s2

Blo

wer

& M

otor

3B

low

er

Rea

r R

etur

nFr

ont S

uppl

y(F

BF)

Rea

r R

etur

nTo

p Su

pply

(FB

T)

Stan

dard

Blo

wer

Orie

ntat

ion

Due

to c

ontin

uing

res

earc

h an

d de

velo

pmen

t, sp

ecifi

catio

ns a

re s

ubje

ct to

cha

nge

with

out

not

ice.

EMD

VDG

IP.P

65R

ev:

10-2

1-03

Stan

dard

Blo

wer

Orie

ntat

ion

Opt

iona

l Blo

wer

Orie

ntat

ion

(979

-033

)

Opt

iona

l Blo

wer

Orie

ntat

ion

(979

-033

)Fr

ont R

etur

nTo

p Su

pply

(FFT

)

Fron

t Ret

urn

Rea

r Su

pply

(FFR

)

FHP

Man

ufac

turin

g C

o.60

1 N

.W. 6

5th

Cou

rtFo

rt La

uder

dale

, FL

3330

9P

hone

: (9

54)

776-

5471

Fax:

(80

0) 7

76-5

529

http

://w

ww

.fhp-

mfg

.com

Page 11: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 410 380 350 315 280 210 - - - - - -

Medium 390 360 330 300 260 - - - - - - -Low 370 340 295 250 - - - - - - - -

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 300 CFM and 1.9 GPM

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM007IP6ISO.P65 Rev:11-3-99

115-1-60 -0 6.6 29.8 2.20 0.10 10.5 15208/230-1-60 -1 3.1 15.9 0.96 0.10 4.8 15

265-1-60 -2 2.9 12.3 0.85 0.10 4.5 15

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch0.90 3 3/8 12

Blower WeightSize Net Ship4x6 119 128

Water Flow (GPM) Press. Drop (FOH)0.9 0.71.2 1.21.4 1.81.6 2.51.9 3.72.1 4.7

8309 445 9828 6323 7586 8309 18.78711 455 10264 5915 7509 8328 19.19121 465 10708 5445 7114 8209 19.69537 475 11158 4540 6276 8164 20.19961 485 11616 - 5349 7331 20.57869 485 9525 5988 7184 7869 16.28250 496 9943 5602 7112 7887 16.68638 507 10368 5157 6738 7774 17.09032 518 10799 4299 5943 7732 17.49433 529 11238 - 5066 6943 17.87442 525 9232 5664 6795 7442 14.27803 536 9633 5298 6726 7460 14.68170 548 10040 4877 6373 7353 14.98543 560 10453 4066 5621 7313 15.38922 572 10872 - 4791 6567 15.66832 584 8825 5199 6238 6832 11.77163 597 9200 4864 6175 6848 12.07500 610 9581 4478 5850 6750 12.37842 623 9968 3733 5160 6713 12.68190 636 10361 - 4398 6028 12.96244 646 8449 4751 5700 6244 9.76546 661 8800 4445 5643 6258 9.96854 675 9157 4092 5346 6169 10.27167 690 9520 3411 4716 6135 10.47485 704 9887 - 4019 5509 10.6

8427 6491 567 4.47993 6021 578 4.17483 5470 590 3.79484 7438 600 4.68996 6911 611 4.38422 6294 624 4.0

10543 8383 633 4.910000 7799 645 4.5

9362 7115 658 4.211546 9263 669 5.110952 8625 682 4.710253 7878 696 4.3

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM007ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance7300 12.3 10000 4.7 8500 17.3 7500 3.8 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 300 CFM and 2.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Page 12: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 350 CFM and 2.4 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM009IP6ISO.P65 Rev: 11-3-99

115-1-60 -0 8.3 40.0 2.20 0.10 12.6 20208/230-1-60 -1 4.0 20.0 0.96 0.10 6.0 15

265-1-60 -2 3.3 16.0 0.85 0.10 5.0 15

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch0.90 3 3/8 12

Blower WeightSize Net Ship4x6 120 129

Water Flow (GPM) Press. Drop (FOH)1.2 1.21.5 2.11.8 3.32.1 4.72.4 6.82.7 8.4

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 410 380 350 315 280 210 - - - - - -

Medium 390 360 330 300 260 - - - - - - -Low 370 340 295 250 - - - - - - - -

10525 552 12410 8009 9609 10525 19.111035 565 12962 7493 9512 10550 19.511554 577 13523 6898 9012 10399 20.012081 589 14092 5751 7950 10342 20.512617 602 14671 - 6776 9286 21.0

9967 602 12022 7585 9100 9967 16.610451 616 12551 7096 9008 9991 17.010942 629 13088 6532 8535 9848 17.411441 643 13634 5446 7529 9794 17.811949 656 14188 - 6417 8795 18.29427 651 11649 7174 8607 9427 14.59884 665 12155 6711 8520 9449 14.9

10349 680 12669 6178 8072 9314 15.210821 695 13191 5151 7120 9263 15.611302 709 13722 - 6069 8318 15.98654 726 11130 6586 7901 8654 11.99073 742 11604 6161 7821 8674 12.29500 758 12086 5672 7410 8550 12.59934 774 12576 4728 6536 8503 12.8

10374 791 13072 - 5571 7636 13.17908 803 10649 6018 7220 7908 9.88291 821 11093 5630 7147 7926 10.18681 839 11544 5183 6771 7813 10.39077 857 12002 4321 5973 7770 10.69480 875 12466 - 5091 6977 10.8

10955 8440 737 4.410391 7829 751 4.1

9728 7112 767 3.712331 9672 779 4.611696 8987 794 4.310950 8184 811 4.013706 10899 822 4.913000 10141 838 4.512171 9252 856 4.215010 12039 871 5.114237 11211 887 4.713329 10239 906 4.3

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM009ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance9800 12.0 13000 4.6 11400 17.2 9800 3.7 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 350 CFM and 3.0 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 13: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 400 CFM and 3.0 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM012IP6ISO.P65 Rev:9-22-03

115-1-60 -0 8.9 50.0 2.20 0.10 13.0 20208/230-1-60 -1 5.0 31.0 0.96 0.10 7.2 15

265-1-60 -2 4.0 22.9 0.85 0.10 5.9 15

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch0.97 4 3/8 14

Blower WeightSize Net Ship4x7 122 132

Water Flow (GPM) Press. Drop (FOH)1.5 2.11.8 3.32.2 5.12.6 7.43.0 11.03.4 13.5

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 425 410 390 371 350 325 300 - - - - -

Medium 410 395 375 355 330 305 - - - - - -Low 385 370 350 330 305 - - - - - - -

12740 724 15210 9695 11632 12740 17.613358 740 15882 9070 11515 12770 18.113986 756 16565 8350 10909 12587 18.514624 772 17259 6961 9623 12519 18.915273 789 17964 - 8202 11241 19.412066 791 14764 9182 11016 12066 15.312651 808 15409 8590 10905 12095 15.713246 826 16064 7908 10332 11921 16.013851 844 16730 6593 9114 11856 16.414465 862 17405 - 7768 10646 16.811412 859 14342 8685 10419 11412 13.311965 878 14961 8125 10314 11439 13.612528 897 15589 7479 9772 11275 14.013100 916 16226 6236 8620 11214 14.313681 936 16874 - 7347 10069 14.610476 963 13760 7972 9564 10476 10.910984 984 14341 7458 9468 10500 11.211500 1006 14931 6866 8970 10350 11.412025 1027 15530 5724 7912 10293 11.712558 1049 16137 - 6744 9243 12.0

9572 1069 13221 7284 8739 9572 9.010036 1093 13766 6815 8651 9595 9.210508 1117 14319 6273 8196 9457 9.410988 1141 14881 5230 7230 9405 9.611475 1165 15451 - 6162 8446 9.8

12305 9073 947 3.811671 8378 965 3.510926 7565 985 3.313849 10430 1002 4.113136 9652 1021 3.812298 8741 1042 3.515393 11783 1058 4.314600 10922 1078 4.013668 9914 1101 3.616857 13039 1119 4.415989 12099 1140 4.114969 10998 1164 3.8

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM012ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance11500 11.1 14500 4.2 13000 15.7 11000 3.2 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 400 CFM and 3.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 14: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 500 CFM and 3.8 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM015IP6ISO.P65 Rev:11-3-99

208/230-1-60 -1 6.8 31.2 0.96 0.10 9.5 15265-1-60 -2 5.8 27.0 0.85 0.10 8.1 15

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch1.42 3 3/8 14

Blower WeightSize Net Ship4x7 139 150

Water Flow (GPM) Press. Drop (FOH)1.9 3.02.3 4.42.8 6.83.3 9.43.8 12.54.3 16.0

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 540 515 490 460 430 390 340 - - - - -

Medium 410 400 390 380 360 330 - - - - - -Low 300 290 280 - - - - - - - - -

16397 917 19526 12478 14970 16397 17.917192 938 20391 11673 14819 16435 18.318000 958 21269 10746 14040 16200 18.818822 979 22161 8959 12385 16111 19.219657 999 23067 - 10556 14467 19.715529 1001 18946 11817 14178 15529 15.516281 1024 19774 11055 14035 15565 15.917047 1046 20616 10177 13297 15342 16.317825 1068 21471 8485 11729 15258 16.718616 1091 22339 - 9997 13701 17.114688 1088 18399 11177 13410 14688 13.515400 1112 19193 10457 13275 14722 13.916124 1136 20000 9626 12577 14512 14.216860 1160 20819 8025 11094 14432 14.517608 1185 21651 - 9456 12960 14.913482 1220 17644 10260 12309 13482 11.114135 1247 18389 9598 12185 13513 11.314800 1274 19147 8836 11544 13320 11.615476 1301 19916 7366 10183 13247 11.916162 1329 20697 - 8679 11895 12.212319 1355 16941 9374 11247 12319 9.112916 1385 17641 8770 11133 12347 9.313523 1415 18351 8073 10548 12171 9.614140 1445 19072 6731 9304 12104 9.814768 1476 19804 - 7930 10869 10.0

16855 12545 1263 3.915987 11596 1287 3.614967 10484 1314 3.318972 14411 1337 4.217995 13348 1362 3.916847 12103 1390 3.621086 16274 1410 4.420000 15097 1437 4.118724 13718 1467 3.723093 18003 1492 4.521904 16718 1520 4.220506 15212 1552 3.9

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM015ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance14500 11.5 20000 4.2 16500 16.5 15000 3.4 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 500 CFM and 4.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 15: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 650 CFM and 4.7 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM018IP6ISO.P65 Rev 11-3-99

208/230-1-60 -1 9.0 48.0 1.8 0.25 13.1 20265-1-60 -2 7.7 42.0 1.6 0.25 11.2 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 770 700 680 650 610 570 530 - - - - -

Medium 670 650 615 570 530 - - - - - - -Low 560 520 510 - - - - - - - - -

20496 985 23857 15597 18713 20496 20.821490 1007 24926 14591 18524 20544 21.322500 1029 26011 13433 17550 20250 21.923527 1051 27114 11199 15481 20139 22.424571 1073 28233 - 13195 18084 22.919411 1076 23083 14772 17722 19411 18.020352 1100 24105 13819 17544 19457 18.521309 1124 25144 12721 16621 19178 19.022282 1148 26199 10606 14661 19073 19.423270 1173 27271 - 12496 17127 19.818360 1168 22345 13972 16763 18360 15.719250 1194 23324 13071 16593 18403 16.120155 1220 24318 12033 15721 18140 16.521075 1246 25327 10032 13867 18040 16.922010 1273 26352 - 11819 16199 17.316852 1310 21323 12825 15386 16852 12.917669 1339 22239 11997 15231 16892 13.218500 1369 23169 11045 14430 16650 13.519345 1398 24114 9208 12729 16559 13.820203 1428 25074 - 10849 14869 14.215398 1455 20364 11718 14059 15398 10.616145 1488 21220 10962 13917 15435 10.916904 1520 22090 10092 13185 15214 11.117676 1553 22973 8414 11631 15130 11.418460 1586 23870 - 9913 13586 11.6

21020 16489 1328 4.619938 15322 1353 4.318666 13953 1381 4.023715 18920 1405 4.922494 17608 1432 4.621059 16071 1462 4.226357 21297 1483 5.225000 19844 1511 4.823405 18142 1543 4.428867 23516 1568 5.427381 21929 1598 5.025634 20068 1631 4.6

Water Flow (GPM) Press. Drop (FOH)2.3 4.42.9 7.23.5 10.74.1 14.84.7 19.45.3 24.9

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch1.88 3 3/8 14

Blower WeightSize Net Ship9x7 166 177

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM018ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance18000 12.5 22000 4.4 21000 17 17500 3.8 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 650 CFM and 5.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 16: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 850 CFM and 5.8 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM024IP6ISO.P65 Rev:11-3-99

208/230-1-60 -1 9.4 49.0 1.8 0.25 13.6 20265-1-60 -2 8.2 44.0 1.6 0.25 11.9 20

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 900 850 800 760 710 690 680 670 - - - -

Medium 750 720 690 670 - - - - - - - -Low 670 - - - - - - - - - - -

26589 1256 30875 20234 24276 26589 21.227878 1284 32259 18929 24031 26652 21.729189 1312 33666 17426 22767 26270 22.230521 1340 35094 14528 20083 26126 22.831876 1369 36545 - 17117 23460 23.325183 1364 29838 19164 22992 25183 18.526404 1395 31162 17928 22760 25242 18.927645 1425 32507 16504 21563 24881 19.428907 1456 33874 13760 19021 24744 19.930190 1487 35261 - 16212 22219 20.323818 1475 28852 18126 21746 23818 16.124973 1508 30118 16957 21527 23874 16.626147 1541 31405 15610 20395 23532 17.027341 1574 32712 13014 17990 23404 17.428554 1608 34038 - 15333 21015 17.821862 1645 27476 16637 19960 21862 13.322922 1682 28660 15564 19759 21914 13.624000 1719 29864 14328 18720 21600 14.025096 1755 31085 11945 16513 21482 14.326209 1793 32326 - 14074 19290 14.619977 1814 26167 15202 18239 19977 11.020945 1855 27273 14222 18055 20024 11.321930 1895 28396 13092 17105 19737 11.622931 1936 29536 10915 15089 19629 11.823948 1977 30693 - 12860 17626 12.1

25225 19786 1594 4.623926 18385 1624 4.322399 16743 1658 4.028458 22705 1686 4.926993 21131 1718 4.625271 19286 1754 4.231628 25557 1779 5.230000 23814 1813 4.828086 21771 1851 4.434641 28218 1882 5.432857 26313 1918 5.030761 24080 1958 4.6

Water Flow (GPM) Press. Drop (FOH)2.9 2.23.6 3.54.4 5.35.1 7.55.8 10.36.5 11.8

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch2.12 3 3/8 14

Blower WeightSize Net Ship9x7 175 187

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM024ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance23000 14.0 29000 4.9 26000 21.0 23000 4.2 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 850 CFM and 6.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 17: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 950 CFM and 7.0 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM028IP6ISO.P65 Rev:11-3-99

208/230-1-60 -1 12.2 56.0 1.8 0.25 17.1 25265-1-60 -2 10.2 55.0 1.6 0.25 14.4 25

208/230-3-60 -3 8.6 51.0 1.8 0.25 12.6 20460-3-60 -4 4.3 25.0 0.9 0.25 6.3 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1250 1170 1120 1070 940 830 740 650 - - - -

Medium 1050 980 920 830 760 700 - - - - - -Low 975 910 870 740 640 - - - - - - -

31015 1441 35932 23603 28317 31015 21.532519 1473 37544 22080 28031 31088 22.134048 1505 39183 20327 26557 30643 22.635602 1537 40848 16947 23426 30476 23.237182 1570 42539 - 19967 27366 23.729379 1566 34724 22358 26823 29379 18.830804 1601 36266 20916 26553 29448 19.232252 1636 37834 19254 25157 29027 19.733724 1671 39426 16053 22191 28868 20.235221 1707 41044 - 18913 25922 20.627779 1693 33554 21140 25362 27779 16.429126 1730 35029 19776 25106 27844 16.830495 1768 36527 18206 23786 27446 17.231887 1806 38049 15178 20982 27295 17.733302 1844 39595 - 17883 24510 18.125506 1888 31948 19410 23287 25506 13.526743 1930 33327 18158 23052 25566 13.928000 1972 34728 16716 21840 25200 14.229278 2014 36151 13936 19265 25062 14.530577 2057 37596 - 16420 22505 14.923306 2082 30411 17736 21279 23306 11.224436 2129 31699 16592 21064 23361 11.525585 2175 33006 15274 19956 23027 11.826753 2222 34334 12734 17603 22901 12.027940 2269 35681 - 15004 20564 12.3

28084 21557 1913 4.326638 19988 1949 4.024938 18150 1990 3.731648 24747 2023 4.630019 22987 2061 4.328104 20925 2104 3.935213 27930 2135 4.833400 25979 2175 4.531269 23693 2220 4.138567 30861 2258 5.036581 28730 2301 4.734247 26232 2349 4.3

Water Flow (GPM) Press. Drop (FOH)3.5 3.44.4 5.35.0 7.45.8 10.37.0 13.68.8 21.4

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch2.29 3 3/8 14

Blower WeightSize Net Ship9x7 203 220

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM028ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance28000 13.1 32000 4.7 32000 18.9 26000 4.0 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 950 CFM and 7.0 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 18: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1000 CFM and 8.1 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM031IP6ISO.P65 Rev:11-5-99

208/230-1-60 -1 14.7 81.0 1.8 0.25 20.2 35265-1-60 -2 12.8 72.0 1.6 0.25 17.6 30

208/230-3-60 -3 10.7 70.0 1.8 0.25 15.2 25460-3-60 -4 5.1 36.0 0.9 0.25 7.3 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1250 1170 1120 1070 940 830 740 650 - - - -

Medium 1050 980 920 830 760 700 - - - - - -Low 975 910 870 740 640 - - - - - - -

35446 1659 41107 26975 32362 35446 21.437165 1696 42951 25235 32036 35529 21.938912 1733 44825 23230 30351 35021 22.540688 1770 46728 19368 26773 34829 23.042494 1808 48662 - 22819 31275 23.533576 1815 39770 25551 30655 33576 18.535204 1855 41535 23903 30346 33655 19.036859 1896 43328 22005 28750 33173 19.438542 1937 45150 18346 25360 32992 19.940252 1978 47000 - 21615 29625 20.431748 1966 38454 24160 28986 31748 16.233287 2009 40142 22602 28693 31822 16.634852 2053 41857 20807 27185 31367 17.036443 2097 43598 17347 23979 31195 17.438060 2142 45367 - 20438 28012 17.829150 2192 36631 22183 26614 29150 13.330563 2241 38210 20752 26345 29218 13.632000 2290 39813 19104 24960 28800 14.033461 2339 41442 15927 22017 28642 14.334945 2389 43096 - 18766 25720 14.626636 2420 34894 20270 24318 26636 11.027927 2474 36368 18962 24073 26698 11.329240 2528 37866 17456 22807 26316 11.630575 2582 39386 14554 20118 26172 11.831931 2637 40929 - 17147 23501 12.1

35059 26784 2425 4.233254 24823 2471 3.931132 22525 2523 3.639566 30843 2557 4.537529 28641 2605 4.235134 26061 2659 3.944280 35124 2683 4.842000 32672 2734 4.539320 29797 2791 4.149490 39842 2828 5.146942 37112 2881 4.843947 33912 2941 4.4

Water Flow (GPM) Press. Drop (FOH)4.0 2.15.1 3.35.8 4.06.8 5.18.1 7.2

10.2 10.6

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch2.29 3 3/8 14

Blower WeightSize Net Ship9x7 210 220

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM031ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance32000 13.3 40000 4.7 37000 19.1 31500 3.7 table for GLHP performance

ARI / ISO 13256-1 PERFORMANCE DATA Rated at 1000 CFM and 7.5 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 19: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1200 CFM and 8.6 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM036IP6ISO.P65 Rev:11-3-99

208/230-1-60 -1 14.7 81.0 3.9 0.5 22.3 35265-1-60 -2 12.8 72.0 2.3 0.5 18.3 30

208/230-3-60 -3 10.1 70.0 3.9 0.5 16.5 25460-3-60 -4 5.0 36.0 2.0 0.5 8.3 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1500 1440 1370 1290 1210 1120 1000 900 - - - -

Medium 1410 1350 1290 1220 1150 1060 900 - - - - -Low 1290 1250 1200 1150 1080 1000 - - - - - -

38770 1814 44961 29504 35397 38770 21.440650 1855 46977 27601 35040 38861 21.942561 1895 49027 25409 33198 38305 22.544504 1936 51109 21184 29284 38095 23.046478 1977 53223 - 24959 34208 23.536724 1986 43499 27947 33529 36724 18.538505 2030 45430 26145 33191 36810 19.040315 2074 47391 24068 31446 36284 19.442155 2119 49384 20066 27738 36085 19.944026 2164 51408 - 23642 32403 20.334724 2149 42058 26425 31703 34724 16.236407 2197 43903 24721 31383 34805 16.638119 2245 45779 22757 29733 34307 17.039859 2293 47684 18973 26227 34119 17.441628 2342 49618 - 22354 30638 17.831883 2398 40066 24263 29109 31883 13.333428 2451 41793 22698 28815 31957 13.635000 2505 43547 20895 27300 31500 14.036598 2559 45329 17421 24081 31328 14.338221 2613 47137 - 20525 28131 14.629133 2647 38165 22170 26598 29133 11.030545 2706 39777 20740 26330 29201 11.331981 2765 41415 19093 24945 28783 11.633441 2824 43078 15918 22004 28625 11.834925 2884 44766 - 18755 25705 12.1

35056 26791 2422 4.233251 24830 2468 3.931129 22533 2520 3.639560 30850 2553 4.537523 28648 2601 4.235129 26069 2655 3.944280 35118 2685 4.842000 32665 2736 4.539320 29790 2793 4.149500 39859 2826 5.146951 37128 2879 4.843955 33927 2939 4.4

Water Flow (GPM) Press. Drop (FOH)4.3 2.45.3 4.06.1 4.77.1 6.38.6 9.5

10.6 14.5

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch3.5 3 3/8 14

Blower WeightSize Net Ship9x7 240 260

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM036ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance34000 14.0 40000 4.7 38000 20.1 31500 4.0 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 1200 CFM and 9.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 20: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1150 CFM and 9.8 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM041IP6ISO.P65 Rev:12-1-99

208/230-1-60 -1 18.9 96.0 3.9 0.5 27.5 45208/230-3-60 -3 12.2 75.0 3.9 0.5 19.2 30

460-3-60 -4 6.2 40.0 2.0 0.5 9.8 15575-3-60 -5 4.9 31.0 2.6 0.75 8.7 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1260 1180 1100 1030 960 870 810 620 - - - -

Medium 1210 1150 1070 1010 940 850 750 - - - - -Low 1160 1100 1040 980 910 830 - - - - - -

41886 2117 49109 31876 38242 41886 19.843917 2164 51300 29820 37857 41985 20.345982 2211 53526 27451 35866 41384 20.848081 2259 55787 22887 31637 41157 21.350214 2306 58084 - 26965 36958 21.840223 2328 48168 30610 36724 40223 17.342173 2380 50294 28636 36353 40318 17.744156 2432 52454 26361 34442 39740 18.246172 2484 54648 21978 30381 39523 18.648220 2537 56876 - 25894 35490 19.038554 2542 47227 29340 35200 38554 15.240423 2598 49289 27447 34845 38645 15.642324 2655 51383 25267 33013 38092 15.944256 2712 53510 21066 29120 37883 16.346220 2770 55669 - 24820 34018 16.735982 2867 45764 27382 32851 35982 12.637726 2931 47725 25616 32520 36066 12.939500 2995 49717 23582 30810 35550 13.241303 3059 51740 19660 27177 35355 13.543136 3124 53794 - 23164 31748 13.833150 3198 44060 25227 30266 33150 10.434757 3269 45909 23600 29960 33228 10.636391 3340 47787 21725 28385 32752 10.938052 3412 49693 18113 25038 32573 11.239741 3484 51628 - 21341 29249 11.4

41555 31006 3092 3.939415 28667 3150 3.736900 25928 3216 3.447096 36028 3244 4.344671 33394 3305 4.041821 30309 3374 3.652714 41124 3397 4.550000 38191 3461 4.246810 34754 3533 3.958544 46388 3563 4.855530 43144 3630 4.551987 39343 3706 4.1

Water Flow (GPM) Press. Drop (FOH)4.9 3.16.1 4.77.0 6.28.2 8.69.8 12.4

12.2 19.1

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch2.29 4 3/8 14

Blower WeightSize Net Ship9x7 235 245

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM041ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance38500 12.5 49000 4.3 41000 16.1 39000 3.8 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 1150 CFM and 9.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 21: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1500 CFM and 10.4 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM042IP6ISO.P65 Rev:12-1-99

208/230-1-60 -1 17.1 96.0 3.9 0.5 25.3 40208/230-3-60 -3 11.1 75.0 3.9 0.5 17.8 25

460-3-60 -4 5.6 40.0 2.0 0.5 9.0 15575-3-60 -5 4.4 31.0 2.6 0.75 8.1 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1560 1500 1420 1340 1260 1170 1070 950 - - - -

Medium 1470 1410 1340 1270 1200 1110 1010 - - - - -Low 1340 1300 1250 1200 1130 1050 - - - - - -

44537 2226 52132 33893 40663 44537 20.046696 2275 54460 31707 40252 44642 20.548892 2325 56825 29189 38136 44003 21.051124 2375 59227 24335 33640 43762 21.553392 2425 61667 - 28672 39297 22.042769 2450 51129 32547 39048 42769 17.544843 2504 53387 30448 38654 42870 17.946951 2559 55682 28030 36622 42256 18.349094 2614 58013 23369 32304 42025 18.851272 2669 60381 - 27533 37737 19.240995 2682 50145 31197 37428 40995 15.342982 2741 52335 29185 37051 41091 15.745003 2801 54560 26867 35102 40503 16.147057 2861 56820 22399 30964 40281 16.449145 2922 59115 - 26391 36171 16.838259 3048 48660 29115 34931 38259 12.640114 3116 50746 27237 34578 38349 12.942000 3184 52864 25074 32760 37800 13.243917 3252 55015 20905 28898 37593 13.545866 3321 57198 - 24630 33757 13.835248 3438 46978 26823 32181 35248 10.336956 3514 48947 25093 31856 35330 10.538694 3591 50946 23100 30181 34825 10.840460 3668 52976 19259 26623 34634 11.042255 3746 55037 - 22691 31100 11.3

42723 32134 3103 4.040523 29734 3162 3.837937 26923 3228 3.448256 37144 3256 4.345771 34450 3318 4.042851 31293 3387 3.753768 42128 3412 4.651000 39140 3476 4.347746 35638 3549 3.959595 47419 3569 4.956527 44121 3636 4.652920 40255 3712 4.2

Water Flow (GPM) Press. Drop (FOH)5.2 3.96.5 5.37.4 6.98.7 9.4

10.4 14.013.0 21.7

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch3.5 3 3/8 14

Blower WeightSize Net Ship9x7 267 287

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM042ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance41500 12.8 50500 4.3 44000 16.9 40000 3.9 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 1500 CFM and 10.0 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 22: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1600 CFM and 12.3 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM048IP6ISO.P65 Rev:11-4-99

208/230-1-60 -1 19.3 102.0 5.2 0.75 29.3 45208/230-3-60 -3 12.9 91.0 5.2 0.75 21.3 30

460-3-60 -4 6.4 42.0 2.5 0.75 10.5 15575-3-60 -5 5.2 39.0 2.6 0.75 9.1 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1980 1960 1930 1840 1800 1730 1680 1610 1500 - - -

Medium 1940 1910 1850 1770 1740 1690 1660 1530 - - - -Low 1900 1870 1810 1730 1710 1600 - - - - - -

51822 2718 61096 39437 47313 51822 19.154334 2778 63814 36893 46836 51944 19.656889 2839 66576 33963 44373 51200 20.059486 2900 69381 28315 39142 50920 20.562125 2962 72230 - 33361 45724 21.049769 3010 60039 37874 45439 49769 16.552182 3077 62680 35431 44981 49886 17.054635 3144 65362 32617 42615 49172 17.457129 3212 68087 27193 37591 48902 17.859664 3280 70854 - 32039 43912 18.247716 3308 59002 36312 43564 47716 14.450029 3381 61565 33970 43125 47828 14.852381 3455 64169 31271 40857 47143 15.254772 3529 66814 26072 36040 46885 15.557202 3604 69500 - 30718 42101 15.944636 3753 57441 33968 40752 44636 11.946800 3836 59889 31777 40341 44740 12.249000 3920 62375 29253 38220 44100 12.551237 4004 64900 24389 33714 43859 12.853510 4089 67462 - 28735 39383 13.141283 4198 55607 31416 37691 41283 9.843284 4291 57926 29390 37311 41379 10.145319 4385 60281 27055 35349 40787 10.347388 4479 62671 22557 31181 40564 10.649490 4574 65098 - 26576 36425 10.8

49919 38128 3456 4.247349 35335 3521 3.944328 32063 3595 3.655533 43217 3610 4.552674 40125 3678 4.249313 36502 3755 3.861148 48299 3766 4.858000 44908 3837 4.454299 40934 3917 4.166763 53382 3922 5.063326 49692 3996 4.659286 45366 4079 4.3

Water Flow (GPM) Press. Drop (FOH)6.2 2.77.7 4.28.8 5.5

10.3 7.512.3 10.715.4 16.8

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch4.5 3 3/8 14

Blower WeightSize Net Ship10x8 310 334

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM048ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance48000 12.2 61000 4.6 58000 18.0 49000 4.0 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 1600 CFM and 12.0 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 23: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1500 CFM and 12.0 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM051IP6ISO.P65 Rev:11-01

208/230-1-60 -1 19.3 102.0 5.2 0.75 29.3 45208/230-3-60 -3 12.9 91.0 5.2 0.75 21.3 30

460-3-60 -4 6.4 42.0 2.5 0.75 10.5 15575-3-60 -5 5.2 39.0 2.6 0.75 9.1 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 1649 1633 1608 1533 1499 1441 1399 1341 1250 - - -

Medium 1616 1591 1541 1474 1449 1408 1383 1274 - - - -Low 1583 1558 1508 1441 1424 1333 - - - - - -

51524 2856 61270 39210 47041 51524 18.054022 2920 63984 36681 46567 51645 18.556562 2983 66741 33767 44118 50906 19.059144 3048 69542 28152 38917 50627 19.461768 3112 72387 - 33169 45461 19.849529 3118 60168 37692 45220 49529 15.951930 3187 62805 35261 44764 49645 16.354372 3257 65484 32460 42410 48935 16.756854 3327 68205 27062 37410 48667 17.159376 3397 70968 - 31885 43701 17.547534 3380 59066 36173 43399 47534 14.149838 3455 61627 33840 42961 47646 14.452182 3530 64227 31153 40702 46964 14.854564 3606 66868 25972 35903 46707 15.156985 3683 69550 - 30601 41941 15.544542 3773 57414 33896 40666 44542 11.846701 3856 59859 31710 40256 44646 12.148897 3941 62342 29191 38139 44007 12.451129 4025 64863 24337 33643 43766 12.753397 4111 67423 - 28674 39300 13.041549 4165 55762 31619 37934 41549 10.043564 4258 58091 29580 37552 41647 10.245612 4351 60456 27230 35577 41051 10.547694 4444 62858 22702 31383 40826 10.749810 4539 65295 - 26748 36660 11.0

50861 38793 3537 4.248242 35946 3604 3.945164 32611 3679 3.656520 43821 3722 4.553610 40671 3792 4.150189 36980 3871 3.862178 48849 3907 4.758977 45395 3981 4.355214 41349 4064 4.067837 53877 4092 4.964345 50120 4169 4.560239 45718 4256 4.1

Water Flow (GPM) Press. Drop (FOH)6.2 2.77.7 4.28.8 5.5

10.3 7.512.3 10.715.4 16.8

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch4.1 3 3/8 14

Blower WeightSize Net Ship10x8 310 334

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM051ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance47500 12.8 62000 4.6 54000 18.0 49500 4.0 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 1500 CFM and 12.0 GPM

For extended range performance beyond the ranges shownon the tables below, the extended range option must be

installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 24: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 2000 CFM and 14.6 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM060IP6ISO.P65 Rev:9-30-00

208/230-1-60 -1 25.6 169.0 5.2 3/4 37.2 60208/230-3-60 -3 17.7 123.0 5.2 3/4 27.3 45

460-3-60 -4 9.0 49.5 2.5 3/4 13.8 20575-3-60 -5 7.2 40.0 2.6 3/4 11.6 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 2160 2090 2030 1960 1870 1800 1730 1680 1640 1600 1550 1500

Medium 2110 2040 1990 1910 1820 1760 1690 1630 1600 - - -Low 2060 1990 1950 1860 1760 1710 1640 - - - - -

65018 3298 76271 49479 59361 65018 19.768170 3371 79673 46287 58762 65170 20.271375 3445 83129 42611 55673 64238 20.774633 3519 86640 35525 49109 63886 21.277944 3594 90206 - 41856 57367 21.762057 3585 74291 47226 56658 62057 17.365066 3665 77571 44180 56087 62203 17.868125 3745 80903 40671 53138 61313 18.271235 3826 84288 33908 46873 60977 18.674395 3907 87725 - 39950 54755 19.059097 3901 72408 44973 53955 59097 15.161962 3988 75569 42072 53411 59235 15.564875 4075 78779 38730 50603 58388 15.967836 4163 82039 32290 44636 58068 16.370846 4251 85350 - 38044 52143 16.754656 4425 69753 41593 49901 54656 12.457306 4523 72737 38911 49397 54784 12.760000 4622 75769 35820 46800 54000 13.062739 4721 78847 29864 41282 53705 13.365523 4821 81972 - 35186 48225 13.650215 4916 66990 38214 45846 50215 10.252650 5025 69796 35749 45384 50333 10.555125 5135 72646 32910 42998 49613 10.757641 5245 75539 27437 37928 49341 11.060199 5357 78476 - 32327 44306 11.2

68853 52605 4762 4.265308 48753 4852 3.961141 44240 4953 3.676598 59613 4978 4.572654 55348 5072 4.268018 50351 5178 3.984343 66621 5194 4.880000 61944 5292 4.474896 56462 5403 4.192087 73629 5410 5.087346 68539 5512 4.681773 62573 5627 4.3

Water Flow (GPM) Press. Drop (FOH)7.2 2.59.1 4.0

10.4 5.212.2 7.114.6 10.219.5 18.2

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch4.5 3 3/8 14

Blower WeightSize Net Ship11x9 336 356

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM060ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance60000 12.5 77000 4.5 65000 17.5 60000 4.0 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 2000 CFM and 15.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 25: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 1800 CFM and 15.0 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM061IP6ISO.P65 Rev:11-01

208/230-1-60 -1 25.6 169.0 5.2 0.75 37.2 60208/230-3-60 -3 17.7 123.0 5.2 0.75 27.3 45

460-3-60 -4 9.0 49.5 2.5 0.75 13.8 20575-3-60 -5 7.2 40.0 2.6 0.75 11.6 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerSpeedHigh 2160 2090 2030 1960 1870 1800 1730 1680 1640 1600 1550 1500

Medium 2110 2040 1990 1910 1820 1760 1690 1630 1600 - - -Low 2060 1990 1950 1860 1760 1710 1640 - - - - -

59093 3111 69709 44970 53952 59093 19.061958 3180 72809 42069 53407 59231 19.564871 3250 75959 38728 50599 58384 20.067832 3320 79159 32288 44633 58064 20.470842 3390 82409 - 38042 52139 20.957345 3445 69101 43640 52356 57345 16.660125 3522 72142 40825 51828 57480 17.162952 3599 75231 37583 49103 56657 17.565826 3676 78369 31333 43314 56347 17.968747 3754 81555 - 36917 50598 18.355598 3779 68493 42310 50761 55598 14.758293 3863 71474 39581 50249 55728 15.161034 3947 74503 36437 47607 54931 15.563820 4032 77579 30378 41994 54630 15.866652 4118 80702 - 35792 49056 16.252977 4280 67581 40315 48368 52977 12.455545 4375 70473 37715 47880 53101 12.758157 4471 73411 34719 45362 52341 13.060811 4567 76393 28946 40014 52054 13.363509 4664 79422 - 34105 46743 13.650355 4781 66669 38320 45975 50355 10.552797 4887 69472 35849 45511 50474 10.855279 4994 72318 33002 43118 49751 11.157802 5101 75208 27514 38034 49479 11.360367 5209 78142 - 32417 44430 11.6

62811 47648 4444 4.159577 44127 4528 3.955776 40003 4623 3.569890 54104 4627 4.466292 50207 4714 4.162062 45642 4813 3.876970 60560 4809 4.773007 56287 4900 4.468349 51280 5003 4.084049 67016 4992 4.979722 62367 5086 4.674635 56918 5193 4.2

Water Flow (GPM) Press. Drop (FOH)7.2 2.59.1 4.0

10.4 5.212.2 7.114.6 10.219.5 18.2

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch4.1 3 3/8 14

Blower WeightSize Net Ship11x9 336 356

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM061ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance58000 13.3 70000 4.5 62000 19.0 57000 4.0 table for GLHP performance

ISO 13256-1 PERFORMANCE DATA Rated at 1800 CFM and 15.0 GPM

For extended range performance beyond the ranges shownon the tables below, the extended range option must be

installed.

Units are complete packages containing refrigerationcompressor, reversing valve, capillary tube metering device,and water to refrigerant heat exchanger. Also included aresafety controls: Overload protection for motors, high and lowrefrigerant pressure switches and a lock-out control circuit.

Extended range option includes expansion valve meteringdevice, insulated water coil and solid state lock-out controls.

Page 26: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 2200 CFM and 16.0 GPM

Units are complete packages containing refrigerationcompressor, reversing valve, expansion valve metering de-vice, and water to refrigerant heat exchanger. Also includedare solid state safety controls: Overload protection for mo-tors, high and low refrigerant pressure switches and a lock-outcontrol circuit.

Extended range option includes insulated water coil.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM070IP6ISO.P65 Rev:9-29-00

208/230-1-60 -1 28.8 169.0 5.2 0.75 43.5 70208/230-3-60 -3 19.1 123.0 5.2 0.75 29.1 45

460-3-60 -4 9.1 62.0 2.5 0.75 13.9 20575-3-60 -5 7.2 50.0 2.6 0.75 11.6 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)MotorSpeedHigh 2260 2229 2202 2177 2139 2093 2040 1977 1917 1855 1790 1729

Medium 1990 1961 1945 1930 1908 1876 1838 1795 1750 1700 1646 -Low 1720 1692 1687 1682 1677 1659 1635 1613 1583 1545 - -

72322 3552 84441 55037 66030 72322 20.475828 3631 88216 51487 65364 72491 20.979393 3710 92052 47398 61927 71454 21.483017 3790 95948 39516 54625 71063 21.986700 3870 99905 - 46558 63812 22.468833 3987 82435 52382 62844 68833 17.372170 4075 86074 49003 62210 68994 17.775563 4164 89771 45111 58939 68007 18.179012 4254 93526 37610 51990 67635 18.682518 4344 97339 - 44312 60733 19.065344 4407 80380 49727 59659 65344 14.868512 4505 83882 46519 59057 65497 15.271733 4603 87438 42825 55952 64560 15.675008 4702 91051 35704 49355 64206 16.078335 4802 94719 - 42066 57655 16.360111 5052 77347 45744 54881 60111 11.963025 5164 80643 42794 54327 60252 12.265988 5277 83991 39395 51471 59389 12.569000 5390 87391 32844 45402 59064 12.872062 5504 90842 - 38697 53037 13.154877 5697 74314 41762 50103 54877 9.657538 5823 77405 39068 49598 55006 9.960243 5950 80544 35965 46990 54219 10.162993 6078 83731 29985 41449 53922 10.465788 6207 86966 - 35328 48420 10.6

71053 53124 5255 4.067395 49127 5354 3.763095 44446 5466 3.479733 61047 5477 4.375628 56589 5580 4.070803 51366 5697 3.688413 68970 5698 4.583861 64051 5806 4.278510 58287 5927 3.997093 76893 5920 4.892094 71513 6032 4.586218 65207 6158 4.1

Water Flow (GPM) Press. Drop (FOH)9.0 4.7

12.5 9.114.2 11.816.0 14.917.8 18.520.0 23.4

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch6.0 3 3/8 14

Blower WeightSize Net Ship

11 x 9 450 495

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM070ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance68000 12.5 82000 4.6 76000 18.7 66000 3.8 table for GLHP performance

ARI / ISO 13256-1 PERFORMANCE DATA Rated at 2200 CFM and 16.0 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 27: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 2300 CFM and 17.3 GPM

Units are complete packages featuring 2 stage operation andcontaining refrigeration compressors, reversing valves,capillary tube metering devices and water to refrigerant heatexchangers. Also included are safety controls: Overloadprotection for motors, high and low refrigerant pressure switchesand a lock-out control circuit.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM072IP6ISO.P65 Rev:11-4-99

208/230-1-60 -1 14.7 74.0 10.2 1 43.3 50208/230-3-60 -3 9.3 68.0 5.0 1 25.9 35

460-3-60 -4 5.0 36.0 2.5 1 13.8 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - 2420 2160 1900 17001/2 Open - - 2980 2800 2610 2400 2100 1800 - - - -Open 2780 2590 2350 2050 1780 - - - - - - -

Water Flow (GPM) Press. Drop (FOH)9.1 4.511.4 7.013.0 9.115.2 12.417.3 16.121.6 25.1

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch7.0 3 3/8 14

Blower WeightSize Net Ship

12x12 590 635

87744 3707 100392 66773 80110 87744 23.791998 3789 104926 62466 79302 87950 24.396323 3872 109534 57505 75132 86691 24.9

100720 3955 114215 47943 66274 86216 25.5105189 4039 118970 - 56486 77419 26.0

81153 3909 94491 61758 74093 81153 20.885087 3996 98721 57774 73345 81344 21.389088 4083 103019 53186 69489 80179 21.893155 4171 107386 44342 61296 79740 22.397288 4259 111820 - 52244 71604 22.874563 4291 89204 56742 68076 74563 17.478177 4386 93143 53082 67389 74738 17.881853 4482 97146 48866 63845 73668 18.385590 4578 101211 40741 56318 73265 18.789387 4675 105340 - 48001 65789 19.164676 4890 81362 49219 59049 64676 13.267812 4999 84868 46044 58454 64828 13.671000 5108 88428 42387 55380 63900 13.974241 5218 92044 35339 48851 63550 14.277535 5328 95716 - 41636 57066 14.654791 5521 73630 41696 50024 54791 9.957447 5644 76704 39007 49519 54919 10.260148 5767 79825 35908 46915 54133 10.462894 5891 82994 29937 41384 53837 10.765684 6016 86210 - 35272 48344 10.9

66474 51424 4411 4.463051 47717 4494 4.159028 43374 4588 3.873300 57668 4581 4.769526 53599 4668 4.465090 48830 4765 4.080125 63907 4753 4.976000 59476 4843 4.671151 54281 4944 4.286952 70148 4925 5.282475 65354 5018 4.877213 59734 5123 4.4

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM072ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance71000 14.0 72000 4.6 81000 18.0 60000 4.1 table for GLHP performance

ARI / ISO 13256-1 PERFORMANCE DATA Rated at 2300 CFM and 16.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Page 28: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Compressor (Ea) Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 2800 CFM and 23.4 GPM

Units are complete packages featuring 2 stage operation andcontaining refrigeration compressors, reversing valves,capillary tube metering devices and water to refrigerant heatexchangers. Also included are safety controls: Overloadprotection for motors, high and low refrigerant pressure switchesand a lock-out control circuit.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM096IP6ISO.P65 Rev:11-4-99

116220 5259 134164 88444 106109 116220 22.1121855 5376 140196 82739 105039 116493 22.7127584 5493 146326 76168 99516 114826 23.2133408 5611 152553 63502 87783 114197 23.8139327 5730 158878 - 74819 102545 24.3109041 5555 127995 82980 99555 109041 19.6114328 5678 133701 77628 98550 109297 20.1119703 5802 139499 71463 93368 107733 20.6125167 5927 145390 59580 82360 107143 21.1130721 6052 151372 - 70197 96210 21.6100950 5909 121112 76823 92168 100950 17.1105844 6040 126453 71868 91238 101187 17.5110821 6172 131880 66160 86440 99739 18.0115880 6305 137392 55159 76249 99193 18.4121021 6438 142989 - 64988 89072 18.8

87449 6808 110678 66549 79841 87449 12.891689 6959 115433 62257 79036 87654 13.296000 7111 120262 57312 74880 86400 13.5

100382 7264 125166 47782 66051 85927 13.8104835 7418 130145 - 56297 77159 14.1

76225 7561 102022 58007 69593 76225 10.179920 7728 106289 54266 68891 76404 10.383678 7897 110623 49956 65269 75310 10.687498 8067 115022 41649 57574 74898 10.891380 8238 119487 - 49071 67256 11.1

94358 73345 6159 4.589500 68090 6275 4.283790 61932 6406 3.8

104637 82918 6366 4.899250 77120 6486 4.592917 70325 6621 4.1

114917 92155 6671 5.0109000 85809 6797 4.7102045 78370 6939 4.3125196 101393 6976 5.3118750 94498 7108 4.9111173 86414 7256 4.5

208/230-1-60 -1 20.5 115.0 12.30 1.5* 58.4 70208/230-3-60 -3 12.4 90.0 6.40 1.5* 34.3 45

460-3-60 -4 6.4 44.0 3.20 1.5* 17.6 20575-3-60 -5 4.8 34.0 2.00 1.5* 12.8 15

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - 2800 2650 2450 2300 22001/2 Open - - 3480 3340 3230 3075 2880 2690 2555 2355 - -Open 3110 2965 2835 2615 2460 2275 - - - - - -

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Water Flow (GPM) Press. Drop (FOH)11.9 4.914.9 7.617.0 9.919.8 13.423.4 18.829.7 30.2

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch9.0 3 3/8 14

Blower WeightSize Net Ship

12x12 660 710

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM096ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance95000 13.2 106000 4.7 100000 18.0 85000 4.1 table for GLHP performance

ARI / ISO 13256-1 PERFORMANCE DATA Rated at 2800 CFM and 21.0 GPM

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

* Vertical configuration shown. Horizontal unit uses one 2.0 Hp motor. All other data remains the same.

Page 29: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 4000 CFM and 30.0 GPM

Units are complete packages featuring 2 stage operation andcontaining refrigeration compressors, reversing valves,capillary tube metering devices and water to refrigerant heatexchangers. Also included are safety controls: Overloadprotection for motors, high and low refrigerant pressure switchesand a lock-out control circuit.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM120IP6ISO.P65 Rev:11-4-99

129544 5877 149594 98583 118273 129544 22.0135824 6007 156319 92224 117080 129848 22.6142210 6138 163153 84899 110924 127989 23.2148702 6270 170095 70782 97846 127289 23.7155299 6403 177146 - 83396 114300 24.3125845 6523 148101 95768 114897 125845 19.3131946 6667 154695 89591 113738 126141 19.8138150 6813 161396 82476 107757 124335 20.3144456 6960 168202 68761 95052 123655 20.8150866 7107 175115 - 81015 111037 21.2120325 7169 144786 91567 109857 120325 16.8126158 7328 151162 85662 108749 120607 17.2132090 7488 157639 78858 103030 118881 17.6138120 7649 164218 65745 90883 118231 18.1144248 7811 170900 - 77461 106166 18.5112045 8234 140140 85266 102297 112045 13.6117477 8417 146194 79767 101265 112308 14.0123000 8601 152345 73431 95940 110700 14.3128615 8785 158591 61221 84629 110094 14.6134321 8972 164933 - 72130 98860 15.0101942 9012 132692 77578 93073 101942 11.3106885 9212 138315 72575 92134 102182 11.6111910 9413 144027 66810 87290 100719 11.9117019 9615 149827 55701 76998 100168 12.2122210 9819 155714 - 65627 89947 12.4

* Vertical configuration shown. Horizontal unit uses two 12x9 blowers and one 3.0 Hp motor. All other data remains the same.

208/230-1-60 -1 27.9 170.0 12.30 2.0* 75.1 100208/230-3-60 -3 17.3 123.0 9.00 2.0* 47.9 60

460-3-60 -4 7.1 49.5 4.50 2.0* 20.5 25575-3-60 -5 5.8 40.0 3.70 2.0* 16.8 20

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - 4400 4150 3830 36001/2 Open - - - 4660 4490 4240 3950 3600 3000 - - -Open 4680 4490 4270 4000 3700 3370 - - - - - -

126988 100332 7812 4.8120450 93290 7960 4.4112765 85038 8126 4.1139982 112426 8076 5.1132775 104698 8229 4.7124303 95640 8401 4.3152871 124410 8341 5.4145000 116001 8499 5.0135748 106144 8677 4.6165970 136609 8605 5.7157425 127509 8768 5.3147381 116839 8951 4.8

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Water Flow (GPM) Press. Drop (FOH)15.7 4.119.6 6.422.4 8.428.0 13.230.0 15.139.2 25.7

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch9.0 3 3/8 14

Blower WeightSize Net Ship

15x15* 725 770

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

PACKAGE UNITS

SPECIFICATION DATA SHEET EM120ENERGY-MISER

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance120000 13.4 142000 5.0 135000 18.0 112000 4.3 table for GLHP performance

ARI / ISO 13256-1 PERFORMANCE DATA Rated at 4000 CFM and 28.0 GPM

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 30: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 5000 CFM and 37.5 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM140IP6ISO.P65 Rev:12-2-99

154357 10479 190111 117466 140928 154357 14.7161841 10711 198387 109890 139507 154720 15.1169450 10945 206794 101162 132171 152505 15.5177185 11180 215333 84340 116588 151671 15.8185047 11417 224003 - 99370 136194 16.2146432 10703 182950 111435 133693 146432 13.7153531 10940 190859 104248 132344 146776 14.0160750 11179 198893 95968 125385 144675 14.4168088 11419 207051 80010 110602 143883 14.7175546 11662 215335 - 94268 129202 15.1138507 11413 177449 105404 126457 138507 12.1145222 11666 185027 98606 125181 138832 12.4152050 11921 192724 90774 118599 136845 12.8158991 12177 200540 75680 104616 136096 13.1166045 12436 208475 - 89166 122209 13.4127530 12527 170272 97051 116435 127530 10.2133713 12804 177402 90791 115261 127830 10.4140000 13084 184643 83580 109200 126000 10.7146391 13365 191994 69682 96325 125311 11.0152886 13649 199455 - 82100 112524 11.2110587 13869 157908 84157 100966 110587 8.0115948 14176 164319 78729 99948 110847 8.2121400 14486 170826 72476 94692 109260 8.4126942 14798 177431 60424 83528 108662 8.6132574 15111 184134 - 71192 97574 8.8

152871 113624 11503 3.9145000 105011 11720 3.6135748 94925 11965 3.3171321 129612 12224 4.1162500 120004 12455 3.8152132 108748 12715 3.5189771 145601 12945 4.3180000 134996 13190 4.0168515 122571 13465 3.7201157 155309 13437 4.4190800 144086 13691 4.1178626 130937 13977 3.7

208/230-3-60 -3 21.4 130.0 9.00 3.0 57.2 70460-3-60 -4 9.6 65.0 4.50 3.0 26.1 35575-3-60 -5 7.9 52.0 3.70 3.0 21.5 25

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - 5300 5020 4750 44101/2 Open - - - 5280 5080 4850 4610 4350 4050 3680 - -Open 5050 4820 4580 4300 4000 3680 - - - - - -

Water Flow (GPM) Press. Drop (FOH)17.5 2.822.4 4.227.0 5.831.9 7.937.5 10.442.4 12.7

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch10.83 3 3/8 14

Blower WeightSize Net Ship

15x15 651 687

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

HORIZONTAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM140ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance140000 11.5 174000 4.2 162000 15.6 142000 3.9 table for GLHP performance

PERFORMANCE DATA Rated at 5000 CFM and 35.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Page 31: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 5000 CFM and 37.5 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM144IP6ISO.P65 Rev:12-2-99

168035 8024 195413 127875 153416 168035 20.9176181 8202 204166 119627 151868 168429 21.5184465 8381 213061 110126 143883 166019 22.0192886 8561 222097 91814 126919 165110 22.5201444 8743 231274 - 108175 148262 23.0158805 8796 188816 120850 144989 158805 18.1166503 8991 197180 113056 143526 159177 18.5174332 9187 205678 104076 135979 156899 19.0182290 9385 214310 86770 119947 156040 19.4190378 9584 223077 - 102233 140118 19.9150485 9567 183129 114519 137393 150485 15.7157781 9779 191148 107133 136007 150838 16.1165199 9993 199295 98624 128855 148679 16.5172740 10208 207570 82224 113663 147866 16.9180404 10424 215972 - 96877 132778 17.3135728 10726 172325 103289 123920 135728 12.7142309 10964 179716 96627 122670 136047 13.0149000 11203 187224 88953 116220 134100 13.3155801 11444 194848 74161 102517 133366 13.6162714 11687 202588 - 87377 119757 13.9120972 11872 161479 92060 110447 120972 10.2126836 12135 168241 86122 109333 121256 10.5132800 12400 175109 79282 103584 119520 10.7138862 12667 182081 66098 91371 118866 11.0145023 12935 189158 - 77877 106737 11.2

151166 118626 9537 4.6143383 110229 9717 4.3134235 100388 9920 4.0171522 137027 10110 5.0162691 127544 10301 4.6152311 116430 10516 4.2191879 155425 10684 5.3182000 144857 10886 4.9170388 132469 11113 4.5212236 173826 11257 5.5201309 162173 11470 5.1188465 148512 11710 4.7

208/230-3-60 -3 17.3 150.0 6.40 1.5 51.7 60460-3-60 -4 9.6 73.0 3.20 1.5 28.0 35575-3-60 -5 7.1 62.0 2.50 1.5 21.0 25

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - 7120 6920 6530 6080 5660 51201/2 Open - - - 6860 6530 6120 5780 5380 4880 4090 - -Open 6670 6300 5880 5430 4970 4340 3750 - - - - -

Water Flow (GPM) Press. Drop (FOH)18.0 3.623.4 6.126.7 7.531.2 9.737.5 13.246.8 19.3

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch14.00 3 3/8 14

Blower WeightSize (Each) Net Ship

12x12 1019 1109

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM144ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance150000 15.3 173000 5.5 177000 23.1 138000 4.9 table for GLHP performance

PERFORMANCE DATA Rated at 5000 CFM and 35.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 32: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 5,000 CFM and 37.5 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM150ENERGY-MISER

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM150IP6ISO.P65 Rev:2-05-01

208/230-3-60 -3 43.0 285.0 9.00 3.0 62.8 100460-3-60 -4 20.5 138.0 4.50 3.0 30.2 50

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - 5000 4825 4650 4475 4300 4100 - -1/2 Open - 5250 5050 4850 4450 4250 4050 - - - - -Open 4950 4550 4350 4150 - - - - - - - -

167,949 9,062 198,868 127,809 153,337 167,949 18.5176,091 9,263 207,695 119,566 151,790 168,343 19.0184,370 9,465 216,665 110,069 143,809 165,933 19.5192,786 9,669 225,776 91,766 126,853 165,025 19.9201,340 9,874 235,028 - 108,119 148,186 20.4158,548 9,729 191,744 120,655 144,754 158,548 16.3166,234 9,945 200,166 112,873 143,294 158,920 16.7174,050 10,162 208,723 103,908 135,759 156,645 17.1181,995 10,381 217,414 86,630 119,753 155,788 17.5190,070 10,601 226,239 - 102,068 139,891 17.9149,602 10,398 185,082 113,847 136,587 149,602 14.4156,855 10,629 193,121 106,505 135,209 149,953 14.8164,230 10,861 201,288 98,045 128,099 147,807 15.1171,727 11,095 209,582 81,742 112,996 146,998 15.5179,346 11,330 218,003 - 96,309 131,999 15.8130,263 11,409 169,191 99,130 118,930 130,263 11.4136,578 11,662 176,369 92,737 117,731 130,569 11.7143,000 11,917 183,659 85,371 111,540 128,700 12.0149,528 12,173 191,061 71,175 98,389 127,996 12.3156,162 12,431 198,576 - 83,859 114,935 12.6110,469 12,532 153,230 84,067 100,858 110,469 8.8115,824 12,810 159,533 78,645 99,841 110,728 9.0121,270 13,090 165,933 72,398 94,591 109,143 9.3126,806 13,372 172,430 60,360 83,438 108,546 9.5132,432 13,655 179,023 - 71,116 97,470 9.7

151,314 111,918 11,546 3.8143,524 103,383 11,765 3.6134,366 93,387 12,010 3.3174,393 132,249 12,352 4.1165,414 122,474 12,585 3.9154,860 111,023 12,848 3.5192,934 148,044 13,156 4.3183,000 137,262 13,405 4.0171,324 124,631 13,685 3.7212,743 165,108 13,961 4.5201,790 153,254 14,225 4.2188,915 139,366 14,522 3.8

Water Flow (GPM) Press. Drop (FOH)19.0 5.522.0 6.925.0 8.830.0 12.837.5 19.542.5 25.0

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch9.0 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 700 750

Units are complete packages featuring 1 stage operation and containingrefrigeration compressor, reversing valve, expansion valve meteringdevice and water to refrigerant heat exchanger. Also included are safety controls:Overload protection for motors, high and low refrigerant pressure switches and asolid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance142,500 12.4 180,000 4.1 175,000 18.1 145,000 3.7 table for GLHP performance

PERFORMANCE DATA Rated at 5,000 CFM and 37.5 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 33: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 6000 CFM and 43.4 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM168IP6ISO.P65 Rev:12-2-99

179044 9414 211165 136252 163467 179044 19.0187724 9623 220557 127464 161818 179464 19.5196550 9833 230100 117340 153309 176895 20.0205522 10044 239794 97829 135234 175927 20.5214641 10257 249639 - 115262 157976 20.9169843 10467 205558 129251 155067 169843 16.2178077 10699 214584 120914 153503 170242 16.6186450 10933 223753 111311 145431 167805 17.1194961 11168 233067 92802 128285 166887 17.5203611 11405 242525 - 109339 149858 17.9164227 11517 203522 124977 149940 164227 14.3172189 11772 212355 116916 148427 164613 14.6180285 12029 221328 107630 140622 162257 15.0188515 12288 230441 89733 124043 161369 15.3196879 12548 239693 - 105724 144903 15.7154858 13229 199997 117847 141386 154858 11.7162366 13523 208506 110247 139959 155222 12.0170000 13818 217147 101490 132600 153000 12.3177760 14115 225921 84614 116966 152163 12.6185647 14414 234829 - 99693 136636 12.9132859 14854 183542 101106 121301 132859 8.9139300 15183 191107 94585 120077 133171 9.2145850 15515 198787 87072 113763 131265 9.4152508 15849 206584 72594 100350 130547 9.6159274 16185 214496 - 85530 117226 9.8

165786 125939 11678 4.2157250 116651 11899 3.9147217 105769 12148 3.6188848 146627 12374 4.5179125 136107 12608 4.2167696 123779 12871 3.8210856 166258 13071 4.7200000 154559 13318 4.4187239 140849 13596 4.0233392 186416 13768 5.0221375 173511 14028 4.6207250 158387 14321 4.2

208/230-3-60 -3 21.8 158.0 9.00 2.0 67.1 80460-3-60 -4 10.3 79.0 4.50 2.0 32.2 40575-3-60 -5 9.0 65.0 3.70 2.0 27.6 35

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - 7200 6840 6460 6050 5610 51401/2 Open - - 7200 6930 6580 6200 5790 5360 4870 - - -Open 6720 6350 5970 5540 5050 4510 - - - - - -

Water Flow (GPM) Press. Drop (FOH)21.7 5.127.1 7.931.0 9.736.2 12.443.4 16.954.3 26.3

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch14.00 3 3/8 14

Blower WeightSize (Each) Net Ship

12x12 1006 1096

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM168ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance174000 13.6 196000 4.8 188000 19.2 150000 4.1 table for GLHP performance

PERFORMANCE DATA Rated at 6000 CFM and 42.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Page 34: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 6000 CFM and 43.4 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCE (AIRFLOW GREATER THAN 6000 CFM IS NOT RECOMMENDED)

CONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM170IP6ISO.P65 Rev:11-01

179044 9414 211165 136252 163467 179044 19.0187724 9623 220557 127464 161818 179464 19.5196550 9833 230100 117340 153309 176895 20.0205522 10044 239794 97829 135234 175927 20.5214641 10257 249639 - 115262 157976 20.9169843 10467 205558 129251 155067 169843 16.2178077 10699 214584 120914 153503 170242 16.6186450 10933 223753 111311 145431 167805 17.1194961 11168 233067 92802 128285 166887 17.5203611 11405 242525 - 109339 149858 17.9164227 11517 203522 124977 149940 164227 14.3172189 11772 212355 116916 148427 164613 14.6180285 12029 221328 107630 140622 162257 15.0188515 12288 230441 89733 124043 161369 15.3196879 12548 239693 - 105724 144903 15.7154858 13229 199997 117847 141386 154858 11.7162366 13523 208506 110247 139959 155222 12.0170000 13818 217147 101490 132600 153000 12.3177760 14115 225921 84614 116966 152163 12.6185647 14414 234829 - 99693 136636 12.9132859 14854 183542 101106 121301 132859 8.9139300 15183 191107 94585 120077 133171 9.2145850 15515 198787 87072 113763 131265 9.4152508 15849 206584 72594 100350 130547 9.6159274 16185 214496 - 85530 117226 9.8

165786 125939 11678 4.2157250 116651 11899 3.9147217 105769 12148 3.6188848 146627 12374 4.5179125 136107 12608 4.2167696 123779 12871 3.8210856 166258 13071 4.7200000 154559 13318 4.4187239 140849 13596 4.0233392 186416 13768 5.0221375 173511 14028 4.6207250 158387 14321 4.2

208/230-3-60 -3 21.8 158.0 9.00 2.0 67.1 80460-3-60 -4 10.3 79.0 4.50 2.0 32.2 40575-3-60 -5 9.0 65.0 3.70 2.0 27.6 35

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - - 5850 5410 49401/2 Open - - - - - 6000 5590 5160 4670 - - -Open - 6050 5770 5340 4850 4310 - - - - - -

Water Flow (GPM) Press. Drop (FOH)21.7 5.127.1 7.931.0 9.736.2 12.443.4 16.954.3 26.3

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch11.00 3 3/8 14

Blower WeightSize (Each) Net Ship

12x12 1520 1620

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

HORIZONTAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM170ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance174000 13.6 196000 4.8 188000 19.2 150000 4.1 table for GLHP performance

PERFORMANCE DATA Rated at 6000 CFM and 42.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 35: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - - - 6450 54001/2 Open - - - - - 6525 5925 5175 3750 - - -Open 6100 5788 5475 4800 3900 - - - - - - -

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

Compressor Blower Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.20 0.30 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 6,000 CFM and 45.0 GPM

Units are complete packages featuring 1 stage operation and containingrefrigeration compressor, reversing valve, expansion valve meteringdevice and water to refrigerant heat exchanger. Also included are safety controls:Overload protection for motors, high and low refrigerant pressure switches and asolid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchanger.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM180ENERGY-MISER

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM180IP6ISO.P65 Rev:2-05-01

208/230-3-60 -3 52.6 425.0 12.20 5.00 78.0 125460-3-60 -4 23.7 187.0 6.10 5.00 35.8 60

213,811 11,401 252,711 162,710 195,210 213,811 18.8224,177 11,654 263,939 152,216 193,240 214,313 19.2234,717 11,908 275,347 140,126 183,079 211,245 19.7245,432 12,164 286,936 116,825 161,494 210,089 20.2256,321 12,422 298,705 - 137,644 188,652 20.6199,570 12,247 241,356 151,873 182,208 199,570 16.3209,245 12,518 251,957 142,078 180,369 200,039 16.7219,084 12,792 262,728 130,793 170,885 197,175 17.1229,084 13,067 273,668 109,044 150,738 196,096 17.5239,248 13,344 284,777 - 128,476 176,087 17.9185,329 13,092 229,999 141,035 169,205 185,329 14.2194,313 13,382 239,974 131,939 167,498 185,764 14.5203,450 13,675 250,107 121,459 158,691 183,105 14.9212,737 13,969 260,398 101,263 139,981 182,103 15.2222,175 14,265 270,847 - 119,308 163,521 15.6163,968 14,361 212,968 124,779 149,702 163,968 11.4171,917 14,679 222,003 116,731 148,192 164,352 11.7180,000 15,000 231,180 107,460 140,400 162,000 12.0188,217 15,323 240,497 89,591 123,846 161,113 12.3196,567 15,647 249,956 - 105,557 144,674 12.6142,605 15,630 195,934 108,523 130,199 142,605 9.1149,519 15,976 204,030 101,523 128,885 142,940 9.4156,549 16,325 212,250 93,460 122,108 140,894 9.6163,695 16,676 220,594 77,919 107,712 140,123 9.8170,958 17,030 229,063 - 91,804 125,825 10.0

183,162 133,357 14,597 3.7173,732 122,985 14,873 3.4162,647 110,841 15,184 3.1207,552 154,269 15,616 3.9196,866 142,576 15,912 3.6184,305 128,881 16,244 3.3231,942 175,181 16,636 4.1220,000 162,167 16,950 3.8205,963 146,922 17,304 3.5256,331 196,093 17,655 4.3243,134 181,757 17,989 4.0227,621 164,962 18,364 3.6

Water Flow (GPM) Press. Drop (FOH)25.0 7.630.0 10.935.0 14.840.0 19.445.0 24.550.0 30.2

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch13.50 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 850 900

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance186,000 14.4 210,000 4.2 227,500 21.5 166,500 3.8 table for GLHP performance

PERFORMANCE DATA Rated at 6,000 CFM and 45.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 36: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 7000 CFM and 54.2 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM210IP6ISO.P65 Rev: 12-2-99

215837 165231 14832 4.3204724 153162 15112 4.0191662 139023 15428 3.6251251 195960 16205 4.5238315 181979 16511 4.2223110 165597 16856 3.9288873 230411 17134 4.9274000 214433 17458 4.6256518 195707 17823 4.2317599 252939 18951 4.9301247 235365 19309 4.6282026 214768 19712 4.2

208/230-3-60 -3 28.8 195.0 6.40 1.5 77.6 100460-3-60 -4 14.7 85.0 3.20 1.5 39.5 50575-3-60 -5 8.4 63.0 2.00 1.5 22.9 30

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - - - 7800 75001/2 Open - - - - - 8600 8200 7600 6900 5240 - -Open 8840 8400 8000 7560 7000 6400 - - - - - -

274728 13621 321203 209068 250827 274728 20.2288047 13923 335552 195584 248296 275373 20.7301590 14227 350133 180049 235240 271431 21.2315357 14533 364944 150110 207505 269946 21.7329349 14841 379987 - 176860 242401 22.2253353 14322 302219 192802 231311 253353 17.7265636 14639 315585 180367 228978 253948 18.1278125 14959 329165 166041 216938 250313 18.6290821 15281 342959 138431 191360 248943 19.0303724 15605 356967 - 163100 223541 19.5237260 15023 288517 180554 216618 237260 15.8248762 15356 301156 168909 214433 237816 16.2260458 15691 313996 155493 203157 234412 16.6272348 16028 327037 129637 179205 233130 17.0284431 16368 340280 - 152739 209341 17.4194029 16314 249691 147656 177148 194029 11.9203435 16675 260332 138132 175361 194484 12.2213000 17040 271139 127161 166140 191700 12.5222723 17406 282113 106016 146552 190651 12.8232605 17775 293253 - 124909 171197 13.1156264 17446 215789 118917 142669 156264 9.0163840 17833 224685 111247 141230 156631 9.2171543 18222 233716 102411 133804 154389 9.4179374 18614 242885 85382 118028 153544 9.6187332 19009 252189 - 100597 137876 9.9

Water Flow (GPM) Press. Drop (FOH)27.1 5.933.9 8.338.0 9.745.2 13.654.2 17.167.8 25.2

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch18.10 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 1170 1260

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM210ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance214000 14.0 260000 5.0 282000 21.7 197000 4.4 table for GLHP performance

PERFORMANCE DATA Rated at 7000 CFM and 50.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 37: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 8000 CFM and 60.9 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM240HIP6ISO.P65 Rev:11-01

208/230-3-60 -3 28.6 179.0 9.00 2.0 82.4 100460-3-60 -4 12.0 90.0 4.50 2.0 36.0 45575-3-60 -5 9.7 72.0 3.70 2.0 29.2 35

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - - - 8300 76601/2 Open - - - - 9320 8980 8480 7900 7200 6000 - -Open 9360 8980 8540 8000 7400 6740 - - - - - -

293955 15457 346696 223700 268381 293955 19.0308206 15800 362116 209272 265674 294645 19.5322697 16145 377784 192650 251704 290427 20.0337428 16492 393699 160616 222027 288838 20.5352399 16842 409863 - 189238 259365 20.9273473 16211 328784 208113 249681 273473 16.9286731 16570 343268 194690 247162 274115 17.3300212 16932 357984 179227 234165 270191 17.7313916 17296 372931 149424 206557 268712 18.1327844 17663 388110 - 176052 241293 18.6252079 16964 309962 191832 230149 252079 14.9264300 17340 323466 179460 227827 252671 15.2276727 17719 337184 165206 215847 249054 15.6289359 18100 351117 137735 190398 247692 16.0302198 18484 365264 - 162280 222417 16.3218623 18382 281342 166372 199603 218623 11.9229222 18789 293331 155642 197589 219136 12.2240000 19200 305508 143280 187200 216000 12.5250955 19612 317873 119455 165129 214818 12.8262090 20028 330426 - 140742 192898 13.1186989 19512 253564 142299 170721 186989 9.6196054 19945 264105 133121 168999 187428 9.8205272 20380 274809 122547 160112 184745 10.1214642 20818 285675 102170 141235 183734 10.3224166 21260 296704 - 120377 164986 10.5

262484 202104 17697 4.3248970 187448 18031 4.0233085 170278 18408 3.7301509 236095 19172 4.6285985 219335 19534 4.3267738 199696 19942 3.9340533 270086 20647 4.8323000 251222 21037 4.5302391 229114 21476 4.1379557 304077 22122 5.0360015 283109 22540 4.7337045 258532 23011 4.3

Water Flow (GPM) Press. Drop (FOH)30.4 3.838.0 5.543.5 6.850.7 9.060.9 13.276.1 20.6

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch18.10 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 1655 1755

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

HORIZONTAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM240ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance240000 13.8 305000 4.8 300000 20.3 240000 4.4 table for GLHP performance

PERFORMANCE DATA Rated at 8000 CFM and 60.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 38: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 8000 CFM and 60.9 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM240IP6ISO.P65 Rev:12-2-99

208/230-3-60 -3 28.6 179.0 9.00 2.0 82.4 100460-3-60 -4 12.0 90.0 4.50 2.0 36.0 45575-3-60 -5 9.7 72.0 3.70 2.0 29.2 35

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - - - 8300 76601/2 Open - - - - 9320 8980 8480 7900 7200 6000 - -Open 9360 8980 8540 8000 7400 6740 - - - - - -

293955 15457 346696 223700 268381 293955 19.0308206 15800 362116 209272 265674 294645 19.5322697 16145 377784 192650 251704 290427 20.0337428 16492 393699 160616 222027 288838 20.5352399 16842 409863 - 189238 259365 20.9273473 16211 328784 208113 249681 273473 16.9286731 16570 343268 194690 247162 274115 17.3300212 16932 357984 179227 234165 270191 17.7313916 17296 372931 149424 206557 268712 18.1327844 17663 388110 - 176052 241293 18.6252079 16964 309962 191832 230149 252079 14.9264300 17340 323466 179460 227827 252671 15.2276727 17719 337184 165206 215847 249054 15.6289359 18100 351117 137735 190398 247692 16.0302198 18484 365264 - 162280 222417 16.3218623 18382 281342 166372 199603 218623 11.9229222 18789 293331 155642 197589 219136 12.2240000 19200 305508 143280 187200 216000 12.5250955 19612 317873 119455 165129 214818 12.8262090 20028 330426 - 140742 192898 13.1186989 19512 253564 142299 170721 186989 9.6196054 19945 264105 133121 168999 187428 9.8205272 20380 274809 122547 160112 184745 10.1214642 20818 285675 102170 141235 183734 10.3224166 21260 296704 - 120377 164986 10.5

262484 202104 17697 4.3248970 187448 18031 4.0233085 170278 18408 3.7301509 236095 19172 4.6285985 219335 19534 4.3267738 199696 19942 3.9340533 270086 20647 4.8323000 251222 21037 4.5302391 229114 21476 4.1379557 304077 22122 5.0360015 283109 22540 4.7337045 258532 23011 4.3

Water Flow (GPM) Press. Drop (FOH)30.4 3.838.0 5.543.5 6.850.7 9.060.9 13.276.1 20.6

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch18.10 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 1250 1340

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM240ENERGY-MISER

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance240000 13.8 305000 4.8 300000 20.3 240000 4.4 table for GLHP performance

PERFORMANCE DATA Rated at 8000 CFM and 60.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 39: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 10000 CFM and 75.0 GPM

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM300ENERGY-MISER

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM300IP6ISO.P65 Rev:12-2-99

208/230-3-60 -3 43.0 285.0 12.20 3.0 121.2 150460-3-60 -4 20.5 138.0 6.10 3.0 58.3 70

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - 10000 9650 9300 8950 8600 8200 - -1/2 Open - 1050010100 9700 8900 8500 8100 - - - - -Open 9900 9100 8700 8300 - - - - - - - -

335897 18124 397735 255618 306674 335897 18.5352181 18526 415390 239131 303580 336685 19.0368740 18930 433329 220138 287617 331866 19.5385573 19337 451551 183533 253707 330050 19.9402680 19747 470057 - 216239 296372 20.4317095 19458 383487 241310 289508 317095 16.3332468 19890 400332 225746 286588 317840 16.7348100 20324 417445 207816 271518 313290 17.1363990 20761 434827 173259 239506 311576 17.5380140 21201 452478 - 204135 279783 17.9299205 20797 370163 227695 273174 299205 14.4313710 21258 386242 213009 270418 299907 14.8328460 21722 402575 196091 256199 295614 15.1343454 22189 419163 163484 225993 293997 15.5358692 22660 436007 - 192618 263997 15.8260527 22818 338381 198261 237861 260527 11.4273157 23324 352738 185474 235461 261138 11.7286000 23833 367318 170742 223080 257400 12.0299056 24346 382123 142350 196779 255992 12.3312324 24862 397152 - 167718 229870 12.6220937 25065 306459 168133 201716 220937 8.8231648 25621 319066 157289 199681 221456 9.0242540 26180 331866 144796 189181 218286 9.3253612 26743 344859 120719 166877 217092 9.5264864 27310 358046 - 142232 194940 9.7

302628 223836 23093 3.8287047 206766 23529 3.6268732 186775 24020 3.3348786 264498 24703 4.1330828 244948 25170 3.9309720 222046 25696 3.5385867 296088 26313 4.3366000 274524 26810 4.0342648 249261 27370 3.7425487 330216 27922 4.5403580 306509 28450 4.2377830 278731 29044 3.8

Water Flow (GPM) Press. Drop (FOH)38.0 5.544.0 6.950.0 8.860.0 12.875.0 19.585.0 25.0

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch18.10 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 1300 1400

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance285000 12.4 360000 4.1 350000 18.1 290000 3.7 table for GLHP performance

PERFORMANCE DATA Rated at 10000 CFM and 75.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown onthe tables below, the extended range option must be installed.

Page 40: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Available External Static Pressure (Inches of Water, Gauge. Wet coil and Filter Included)BlowerPulley

Closed - - - - - - - - - - 12900108001/2 Open - - - - - 130501185010350 7500 - - -Open 122001157510950 9600 7800 - - - - - - -

Entering Heating Heat of PowerWater Capacity Absorb. Input COPTemp. BTUH BTUH Watts

60O

50O 70O

80O

60O

60O 70O

80O

60O

70O 70O

80O

60O

80O 70O

80O

Entering Ent. Air Total Heat Sensible Capacity BTUHWater Wet Bulb Capacity Rejection Ent. Air Dry Bulb Temp. EERTemp. Temp. BTUH BTUH 75o 80o 85o

61O

64O

50O 67O

70O

73O

61O

64O

60O 67O

70O

73O

61O

64O

70O 67O

70O

73O

61O

64O

85O 67O

70O

73O

61O

64O

100O 67O

70O

73O

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS

Compressor (Ea) Blower (Each) Min. Max.Circuit Fuse

RLA LRA NPA HP Ampacity Size

Electrical Elect.Characteristics Symbol

0.20 0.30 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20

WattsInput

DryBulb

CAPACITY DATAAll performance at 12,000 CFM and 90.0 GPM

Units are complete packages featuring 2 stage operation and containingrefrigeration compressors, reversing valves, expansion valve meteringdevices and water to refrigerant heat exchangers. Also included are safetycontrols: Overload protection for motors, high and low refrigerant pressure switchesand a solid state lock-out control circuit.

Extended range package includes insulated water to refrigerant heatexchangers.

FHP MANUFACTURING601 N.W. 65th Court

Fort Lauderdale, FL 33309Phone: (954) 776-5471

Fax: (800) 776-5529http://www.fhp-mfg.com

VERTICAL PACKAGE UNITS

SPECIFICATION DATA SHEET EM360ENERGY-MISER

ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS

BLOWER PERFORMANCECONDENSER WATER FLOW

COOLING HEATING

As a result of continuing research and development, specifications are subject to change without notice. EM360IP6ISO.P65 Rev:5-5-03

208/230-3-60 -3 52.6 425.0 12.20 5.00 142.8 175460-3-60 -4 23.7 187.0 6.10 5.00 65.5 80

427622 22802 505422 325421 390419 427622 18.8448354 23307 527878 304432 386481 428626 19.2469434 23816 550694 280252 366159 422491 19.7490863 24328 573871 233651 322988 420179 20.2512642 24844 597409 - 275289 377304 20.6399140 24493 482712 303746 364415 399140 16.3418491 25036 503915 284155 360739 400077 16.7438167 25583 525456 261586 341770 394350 17.1458169 26133 547336 218088 301475 392193 17.5478497 26687 569554 - 256953 352174 17.9370657 26184 459998 282070 338410 370657 14.2388627 26765 479948 263878 334996 371527 14.5406899 27349 500214 242919 317381 366209 14.9425474 27937 520795 202525 279962 364205 15.2444351 28529 541693 - 238616 327042 15.6327935 28722 425935 249559 299405 327935 11.4343833 29359 444006 233463 296384 328705 11.7360000 30000 462360 214920 280800 324000 12.0376433 30645 480995 179182 247693 322227 12.3393135 31295 499913 - 211113 289347 12.6285211 31259 391868 217046 260398 285211 9.1299038 31952 408059 203047 257771 285880 9.4313098 32650 424500 186920 244216 281788 9.6327391 33352 441189 155838 215423 280246 9.8341916 34059 458126 - 183609 251650 10.0

366325 266714 29194 3.7347464 245971 29746 3.4325294 221681 30367 3.1415104 308538 31233 3.9393732 285152 31823 3.6368610 257762 32488 3.3463884 350362 33271 4.1440000 324333 33900 3.8411926 293844 34608 3.5512662 392185 35310 4.3486267 363513 35977 4.0455241 329924 36728 3.6

Water Flow (GPM) Press. Drop (FOH)50.0 7.660.0 10.970.0 14.880.0 19.490.0 24.5

100.0 30.2

EvaporatorSquare Rows Tube Fins Per

Feet Deep Size (O.D.) Inch27.00 3 3/8 14

Blower WeightSize (Each) Net Ship

15x15 1600 1700

Water Loop Ground Water Ground LoopCooling Heating Cooling Heating Cooling Heating

Capacity EER Capacity COP Capacity EER Capacity COP See extended range perfomance372000 14.4 420000 4.2 455000 21.5 333000 3.8 table for GLHP performance

PERFORMANCE DATA Rated at 12000 CFM and 90.0 GPM. Rated in accordance with ISO 13256-1.

For extended range performance beyond the ranges shown on thetables below, the extended range option must be installed.

Page 41: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

EM007 through EM120 are certified to ARI / ISO Standard 13256-1 for Ground Loop Heat Pump applications.EM140-EM360 are beyond the scope of ARI / ISO Standard 13256-1 but are rated in accordance with therating conditions of the Ground Loop Heat Pump application point.

ISO 13256-1 Ground Loop Heat Pump Rating ConditionsEntering Air Temp Entering

Dry Bulb Wet Bulb Fluid TempCooling 80.6oF (27oC) 66.2oF (19oC) 77oF (25oC)Heating 68oF (20oC) 32oF (0oC)

All EM-Series units must have the optional extended range performance option installed to run at conditionsoutside of those shown in the performance tables of the individual unit specification data sheets. The ratingsshown above reflect the use of the extended range performance option.

Minimum entering fluid temperature with fresh water is 45oF (7.2oC). The above ratings are based on the useof a solution of 15% methanol and 85% water by weight. FHP recommends antifreeze protection to at least20oF (11oC) below the lowest entering fluid temperature.

Note: Published fluid side pressure drop tables are based on 70o (21oC) fresh water. When designing thesystem, pressure drop should be modified for antifreeze content and fluid temperature. FHP recommendsadding 0.2% to the system pressure drop for every 1oF (0.36% / 1oC) below 70oF (21oC) in addition to anyantifreeze correction factors.

As a result of continuing research and development, specifications are subject to change without notice. EMEXRRIP6.P65 Rev:2-21-01

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS, ENERGY-MISER LINE

EM-SERIES

EXTENDED RANGE RATINGSModel Number Rated CFM Rated GPM Cooling Capacity EER Heating Capacity COP

EM007 300 2 7,500 13.6 5,500 3.2EM009 350 3 10,000 13.2 7,200 3.0EM012 400 3 11,800 12.2 8,200 2.7EM015 500 4 14,800 12.7 11,000 2.8EM018 650 5 19,000 13.4 13,000 3.2EM024 850 6 24,000 15.5 17,000 3.5EM028 950 7 29,500 14.6 19,000 3.3EM031 1000 7.5 34,500 14.7 23,500 3.0EM036 1200 9 35,000 15.3 23,500 3.4EM041 1100 9 39,000 13.3 28,000 3.2EM042 1400 10 42,500 13.6 30,000 3.2EM048 1600 12 51,000 13.4 38,000 3.4EM060 2000 15 60,500 14.0 48,000 3.2EM070 2200 16 69,000 13.9 53,000 3.4EM072 2400 16 73,000 15.8 47,000 3.6EM096 2800 22 96,000 15.0 66,000 3.5EM120 4000 28 124,000 16.2 92,000 3.6EM140 5000 35 143,000 12.3 104,000 3.2EM144 5000 35 156,000 17.1 100,000 4.1EM150 5000 37.5 150,000 13.4 105,000 2.9

EM168/170 6000 42 175,000 14.7 112,000 3.4EM180 6000 45 194,000 16.0 120,000 3.2EM210 7000 50 235,000 16.4 145,000 3.8EM240 8000 60 260,000 15.5 170,000 3.7EM300 10000 75 300,000 13.4 210,000 2.9EM360 12000 90 389,000 16.0 240,000 3.2

Page 42: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

Minimum entering fluid temperature with fresh water is 45oF (7.2oC). The above ratings are based on the use of a solution of 15%methanol and 85% water by weight. FHP recommends antifreeze protection to at least 20oF (11oC) below the lowest entering fluidtemperature. Coefficients of Performance do not include a pumping power penalty.Note: Published fluid side pressure drop tables are based on 70o (21oC) fresh water. When designing the system, pressure dropshould be modified for antifreeze content and fluid temperature. FHP recommends adding 0.2% to the system pressure drop for every1oF (0.36% / 1oC) below 70oF (21oC) in addition to any antifreeze correction factors.

As a result of continuing research and development, specifications are subject to change without notice. EMLTHIP6.P65 1/3 Rev:1-5-00

Entering Heating Heat of PowerFluid Capacity Absorb. Input COP

Temp. BTUH BTUH Watts60o 5770 4089 493 3.4

25o 70o 5473 3760 502 3.280o 5124 3375 512 2.9

EM007 60o 6247 4515 507 3.61.9 GPM 30o 70o 5925 4161 517 3.4300 CFM 80o 5547 3746 528 3.1

60o 7311 5483 536 4.040o 70o 6935 5072 546 3.7

80o 6493 4591 557 3.460o 7502 5316 641 3.4

25o 70o 7116 4888 653 3.280o 6662 4387 667 2.9

EM009 60o 8121 5871 660 3.62.4 GPM 30o 70o 7703 5410 672 3.4350 CFM 80o 7212 4871 686 3.1

60o 9505 7128 697 4.040o 70o 9016 6593 710 3.7

80o 8441 5968 725 3.460o 8426 5613 824 3.0

25o 70o 7992 5126 840 2.880o 7482 4556 858 2.6

EM012 60o 9121 6227 848 3.23.0 GPM 30o 70o 8651 5703 864 2.9400 CFM 80o 8099 5089 882 2.7

60o 10676 7618 896 3.540o 70o 10126 7011 913 3.3

80o 9480 6300 932 3.060o 11542 7792 1099 3.1

25o 70o 10948 7127 1120 2.980o 10249 6348 1143 2.6

EM015 60o 12494 8637 1131 3.23.8 GPM 30o 70o 11851 7920 1152 3.0500 CFM 80o 11095 7082 1176 2.8

60o 14625 10550 1194 3.640o 70o 13872 9720 1217 3.3

80o 12987 8748 1242 3.160o 14429 10484 1156 3.7

25o 70o 13686 9667 1178 3.480o 12813 8709 1203 3.1

EM018 60o 15685 11629 1189 3.94.7 GPM 30o 70o 14877 10745 1211 3.6650 CFM 80o 13928 9710 1236 3.3

60o 18353 14070 1255 4.340o 70o 17408 13044 1279 4.0

80o 16297 11842 1306 3.7

Entering Heating Heat of PowerFluid Capacity Absorb. Input COP

Temp. BTUH BTUH Watts

ModelNumber

DryBulb

ModelNumber

DryBulb

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS, ENERGY-MISER LINE

EM SERIES with extended range option

LOW TEMP HEATING PERFORMANCE

60o 17316 12584 1387 3.725o 70o 16424 11603 1413 3.4

80o 15376 10454 1443 3.1EM024 60o 18821 13955 1426 3.9

5.8 GPM 30o 70o 17852 12894 1453 3.6850 CFM 80o 16713 11652 1483 3.3

60o 22023 16886 1506 4.340o 70o 20889 15655 1534 4.0

80o 19556 14213 1566 3.760o 19279 13602 1664 3.4

25o 70o 18286 12503 1695 3.280o 17119 11215 1730 2.9

EM028 60o 20955 15115 1712 3.67.0 GPM 30o 70o 19876 13925 1744 3.3950 CFM 80o 18608 12533 1780 3.1

60o 24519 18354 1807 4.040o 70o 23257 16976 1841 3.7

80o 21773 15360 1879 3.460o 24259 17120 2092 3.4

25o 70o 23010 15736 2132 3.280o 21542 14116 2177 2.9

EM031 60o 26338 18988 2154 3.68.1 GPM 30o 70o 24982 17493 2195 3.3

1000 CFM 80o 23388 15742 2241 3.160o 30588 22792 2285 3.9

40o 70o 29013 21070 2328 3.780o 27162 19053 2377 3.360o 24253 17137 2086 3.4

25o 70o 23004 15754 2125 3.280o 21536 14134 2169 2.9

EM036 60o 26331 18997 2149 3.68.6 GPM 30o 70o 24975 17503 2190 3.3

1200 CFM 80o 23381 15753 2236 3.160o 30575 22789 2282 3.9

40o 70o 29001 21068 2325 3.780o 27151 19052 2374 3.460o 27814 18578 2707 3.0

25o 70o 26382 16972 2758 2.880o 24699 15092 2816 2.6

EM041 60o 30578 21095 2779 3.29.8 GPM 30o 70o 29004 19341 2832 3.0

1150 CFM 80o 27153 17289 2891 2.860o 36078 26061 2936 3.6

40o 70o 34220 24015 2991 3.480o 32037 21618 3053 3.1

Page 43: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

As a result of continuing research and development, specifications are subject to change without notice. EMLTHIP6.P65 2/3 Rev:2-21-01

Entering Heating Heat of PowerFluid Capacity Absorb. Input COP

Temp. BTUH BTUH Watts

Entering Heating Heat of PowerFluid Capacity Absorb. Input COP

Temp. BTUH BTUH Watts

ModelNumber

DryBulb

ModelNumber

DryBulb

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS, ENERGY-MISER LINE

EM SERIES with extended range option

LOW TEMP HEATING PERFORMANCE

Minimum entering fluid temperature with fresh water is 45oF (7.2oC). The above ratings are based on the use of a solution of 15%methanol and 85% water by weight. FHP recommends antifreeze protection to at least 20oF (11oC) below the lowest entering fluidtemperature. Coefficients of Performance do not include a pumping power penalty.Note: Published fluid side pressure drop tables are based on 70o (21oC) fresh water. When designing the system, pressure dropshould be modified for antifreeze content and fluid temperature. FHP recommends adding 0.2% to the system pressure drop for every1oF (0.36% / 1oC) below 70oF (21oC) in addition to any antifreeze correction factors.

60o 29015 19736 2720 3.125o 70o 27521 18066 2771 2.9

80o 25765 16113 2829 2.7EM042 60o 31791 22264 2792 3.3

10.4 GPM 30o 70o 30154 20447 2845 3.11500 CFM 80o 28230 18320 2904 2.8

60o 37260 27204 2947 3.740o 70o 35342 25096 3003 3.4

80o 33087 22627 3066 3.260o 35543 25035 3080 3.4

25o 70o 33713 23006 3138 3.180o 31562 20631 3204 2.9

EM048 60o 38689 27923 3155 3.612.3 GPM 30o 70o 36697 25727 3215 3.31800 CFM 80o 34356 23157 3282 3.1

60o 44303 33041 3301 3.940o 70o 42022 30547 3363 3.7

80o 39341 27627 3433 3.460o 49024 34615 4223 3.4

25o 70o 46500 31818 4303 3.280o 43533 28545 4393 2.9

EM060 60o 53364 38586 4331 3.614.6 GPM 30o 70o 50616 35559 4413 3.42000 CFM 80o 47386 32015 4505 3.1

60o 61108 45594 4547 3.940o 70o 57962 42154 4633 3.7

80o 54264 38126 4730 3.460o 49354 33317 4700 3.1

25o 70o 46813 30473 4789 2.980o 43826 27145 4889 2.6

EM070 60o 53694 37278 4811 3.316.0 GPM 30o 70o 50929 34203 4902 3.02200 CFM 80o 47680 30605 5004 2.8

60o 62373 45201 5033 3.640o 70o 59162 41665 5128 3.4

80o 55387 37525 5235 3.160o 49515 35933 3981 3.6

25o 70o 46966 33127 4056 3.480o 43969 29841 4141 3.1

EM072 60o 53665 39788 4067 3.917.3 GPM 30o 70o 50902 36763 4144 3.62300 CFM 80o 47654 33220 4231 3.3

60o 59963 45500 4239 4.140o 70o 56876 42140 4319 3.9

80o 53247 38203 4409 3.5

60o 66868 47619 5641 3.525o 70o 63425 43813 5748 3.2

80o 59378 39356 5868 3.0EM096 60o 72166 52565 5744 3.7

23.4 GPM 30o 70o 68450 48480 5853 3.42800 CFM 80o 64083 43695 5975 3.1

60o 83974 63667 5952 4.140o 70o 79650 58960 6064 3.8

80o 74568 53446 6191 3.560o 91807 67344 7170 3.8

25o 70o 87080 62155 7305 3.580o 81524 56079 7458 3.2

EM120 60o 98892 73977 7302 4.030.0 GPM 30o 70o 93800 68415 7440 3.74000 CFM 80o 87815 61900 7595 3.4

60o 112940 87158 7556 4.440o 70o 107125 80856 7699 4.1

80o 100290 73472 7860 3.760o 105375 72280 9700 3.2

25o 70o 99950 66229 9883 3.080o 93573 59148 10089 2.7

EM140 60o 112808 78484 10060 3.337.5 GPM 30o 70o 107000 72027 10250 3.15000 CFM 80o 100173 64470 10464 2.8

60o 133367 96581 10781 3.640o 70o 126500 89019 10985 3.4

80o 118429 80165 11214 3.160o 100274 72630 8102 3.6

25o 70o 95111 66945 8255 3.480o 89043 60288 8427 3.1

EM144 60o 110452 81827 8389 3.937.5 GPM 30o 70o 104765 75599 8548 3.65000 CFM 80o 98081 68306 8727 3.3

60o 130809 100228 8963 4.340o 70o 124074 92916 9132 4.0

80o 116158 84348 9323 3.760o 101449 68916 9535 3.1

25o 70o 96226 63078 9715 2.980o 90086 56246 9918 2.7

EM150 60o 111782 77893 9932 3.337.5 GPM 30o 70o 106027 71498 10120 3.15000 CFM 80o 99262 64011 10331 2.8

60o 130488 93838 10742 3.640o 70o 123770 86427 10945 3.3

80o 115873 77750 11173 3.0

Page 44: EMIP60 ISO EM Series, Inch Pounds - 60 Hz EM007-360 (iso ...millpondmech.net/uploads/3/1/8/4/3184737/em_specs_2003_small.pdfwith Galvalume® plus, an aluminum-zinc alloy with a clear

As a result of continuing research and development, specifications are subject to change without notice. EMLTHIP6.P65 3/3 Rev:2-21-01

Entering Heating Heat of PowerFluid Capacity Absorb. Input COP

Temp. BTUH BTUH Watts

Entering Heating Heat of PowerFluid Capacity Absorb. Input COP

Temp. BTUH BTUH Watts

ModelNumber

DryBulb

ModelNumber

DryBulb

FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS, ENERGY-MISER LINE

EM SERIES with extended range option

LOW TEMP HEATING PERFORMANCE

Minimum entering fluid temperature with fresh water is 45oF (7.2oC). The above ratings are based on the use of a solution of 15%methanol and 85% water by weight. FHP recommends antifreeze protection to at least 20oF (11oC) below the lowest entering fluidtemperature. Coefficients of Performance do not include a pumping power penalty.Note: Published fluid side pressure drop tables are based on 70o (21oC) fresh water. When designing the system, pressure dropshould be modified for antifreeze content and fluid temperature. FHP recommends adding 0.2% to the system pressure drop for every1oF (0.36% / 1oC) below 70oF (21oC) in addition to any antifreeze correction factors.

60o 112822 78916 9937 3.325o 70o 107013 72467 10125 3.1

80o 100185 64917 10336 2.8EM168/170 60o 123140 88049 10285 3.543.4 GPM 30o 70o 116800 81046 10479 3.36000 CFM 80o 109348 72847 10698 3.0

60o 143778 106309 10982 3.840o 70o 136375 98198 11189 3.6

80o 127674 88699 11423 3.360o 122188 81076 12049 3.0

25o 70o 115897 74008 12277 2.880o 108502 65738 12533 2.5

EM180 60o 134383 91531 12559 3.145 GPM 30o 70o 127464 83802 12797 2.9

6000 CFM 80o 119331 74758 13064 2.760o 158773 112445 13578 3.4

40o 70o 150598 103395 13835 3.280o 140989 92800 14123 2.960o 144116 105227 11398 3.7

25o 70o 136696 97072 11613 3.480o 127974 87523 11856 3.2

EM210 60o 159887 118654 12085 3.954.2 GPM 30o 70o 151655 109643 12313 3.67000 CFM 80o 141979 99089 12570 3.3

60o 191430 145512 13458 4.240o 70o 181574 134789 13712 3.9

80o 169989 122226 13998 3.660o 164924 117125 14009 3.5

25o 70o 156433 107730 14274 3.280o 146452 96732 14572 2.9

EM240 60o 184436 134121 14746 3.760.9 GPM 30o 70o 174940 123675 15025 3.48000 CFM 80o 163778 111442 15339 3.1

60o 223460 168112 16222 4.040o 70o 211955 155561 16528 3.8

80o 198431 140860 16873 3.460o 202899 137833 19070 3.1

25o 70o 192452 126157 19430 2.980o 180173 112493 19836 2.7

EM300 60o 223565 155786 19865 3.375.0 GPM 30o 70o 212054 142995 20240 3.1

10000 CFM 80o 198524 128023 20663 2.860o 260977 187676 21483 3.6

40o 70o 247540 172855 21889 3.380o 231746 155501 22346 3.0

60o 244376 162151 24099 3.025o 70o 231794 148016 24554 2.8

80o 217005 131477 25067 2.5EM360 60o 268766 183062 25118 3.1

90.0 GPM 30o 70o 254928 167605 25593 2.912000 CFM 80o 238663 149515 26128 2.7

60o 317545 224889 27156 3.440o 70o 301196 206789 27669 3.2

80o 281978 185600 28247 2.9