China EM Technology Limited
Products Selection Guide
Address: No.80,Baomin 2 road Xixiang, Bao’an district, Shenzhen, China
Tel: +86-755-29985851
Fax: +86-755-29970305
Zip code: 518101
Website: www.emheater.com
China EM Technology Limited
EMHEATER®
EMHEATER®
Brake UnitMatch inverter: 0.75KW~630KW
Brake resistor & Aluminum resistorPower range: 15W~20KWResistance value: 0.01Ohm~100KOhmMatch inverter: 0.75KW~630KW
Welcome to visit EMHEATER Group Corporation!
We have 6 factories and more than 820 staff. As a professional manufacturer of industrial automation products, we are always dedicated to soft starter, frequency inverters, servo motor and drive, EMI filters, harmonic wave AC chokes, sine wave filters and brake units and resistors. In the year of 2008, EMHEATER Group does have established “China EM Technology Limited” to cultivate oversea market.
We have following mature series product:EM-GJ3 series soft starter, EM9 series sensorless vector control inverter, EM10 series vector control inverter with PG (including elevator and lift drive). EM11 series vector control inverter, EMA to EMD series servo motor drive system.
And relative accessories, such as input filter, output filter, input choke , output choke, DC choke and sine wave filter, brake unit and resistor and aluminum resistor.
Our company's feature is good products with competitive price!
We are sincerely looking for worldwide partners to cooperate with us to build a win-win market environment.
Input & output filter and AC chokeVoltage range: 220V~690VPower range: 0.75KW~630KW
Sine wave filterVoltage range: Three phase 220V~690VPower range: 0.75KW~630KW
DC ChokeVoltage range: DC 500V~700VPower range: 0.4KW~560KW
1 Soft Starter
3 EM11 Series Frequency Inverter
2 EM9 Series Frequency Inverter
4 Servo Drive & Servo Motor
5 AC Filter and AC/DC Choke
6 Brake Unit and Resistor
Type:
EM11-S series: Vector control inverter for Servo
EM11-L series: Vector control inverter for Lift
EM11-T series: Torque control frequency inverter
EM11-G series: Vector control frequency inverter for General use
EM11-G1E/G3E: Economy vector control inverter for General use
EM11-P series: Vector control frequency inverter for Fan or Pump
Voltage range: 220V/380V/480V/690V.
Power range: 0.75KW~450KW.
Type:EM-GJ series: Soft starter for general use
Voltage range: 220V/380V/480V/690V.
Power range: 0.75~600KW.
Type:
EM9-B series: Vector control inverter for Ball mill machineEM9-C series: Vector control inverter for CNC machine
EM9-E series: Vector control inverter for Energy saving control cabinet
EM9-H series: Vector control inverter for Heavy load
EM9-G series: Vector control inverter for General useEM9-P series: Vector control inverter for Fan or PumpEM9-Z series: Vector control inverter for Injection machine
Voltage range: 220V/380V/480V/575V/690V
Power range: 0.75KW~630KW
Servo drive: EMA~EMD seriesServo motor: EMM-60/80 SeriesEMM-110/130 SeriesEMM-180 SeriesEMM-220 SeriesVoltage range: 220V/380VVoltage range: 220V/380VPower range: 0.2KW ~ 22KW
2 3
4 7
8 11
12 16
17 20
20 21
Company Introduction Product Series
Current(A)
External Shape(mm)
InstallationDimensions(mm)
Power(KW)Model Soft Starter
Cabinet ModelGJ2(220V) GJ3(380V) GJ4(480V) GJ2 GJ3 GJ4 W1 H1 D W2 H2 d
EM-GJ series Soft Starter is a new type start-up equipment which integrates electric force and electronic techniques , computer technique and modern control theory. It is the new generation product to replace the conventional Star-delta Starter, Self-coupling voltage-drop Starter and Magnetic control voltage-drop Starter.Supply Power Breaker Input AC Choke Input AC Filter
AC Motor Output AC Choke Output AC Filter
DC Choke( )Improve power factor
Brake Unit
Brake resistor
Peripheral Devices Connection
Three phase power supply
Circuit breaker(QF)
By-pass contactor(KM)
Motor soft starter
Operation control panel
12 control terminals
AC Motor
Product Introduction
Product Features
Reduce the starting current, reduce power supply peak current, reduce the cost of distribution equipment. Reduce the abrasion of motor, improve the service life of mechanical equipment.
Optional starting parameters are convenient in one soft starter starting different motors.
Soft starter inspects motor feedback voltage to realize closed loop control, ensure the motor start-up success in different conditions and different loads.
A variety of starting ways: voltage ramp starting way can get the maximum output torque; Current limiting can realize biggest limitations of the soft start starting current.
Reliable quality assurance: using computer simulation design; SMT production process; Excellent electromagnetic compatibility performance; High temperature aging, vibration test of the machine before delivery.
Perfect and reliable protection function: loss of voltage, less voltage, over voltage protection; overheating, starting time too long; Input phase lost, output phase lost, three-phase imbalance; starting over current, overload and load short circuit protection, etc.
Full dynamic control field-bus monitoring starter, easy networking.
LED displaying screen can display parameter code, state and error.
Model Introduction
EM - GJ 3 - 015 [C]
EMHEATERSoft starter
GJ: General Use
Product Type
2: 3 PH 220~240V3: 3 PH 380~460V4: 3 PH 460~500V
Input Voltage Adaptable Motor
015: 15KW5d5: 5.5KW
EM-GJ3-5d5
EM-GJ3-7d5
EM-GJ3-011
EM-GJ3-015
EM-GJ3-018
EM-GJ3-022
EM-GJ3-030
EM-GJ3-037
EM-GJ3-045
EM-GJ3-055
EM-GJ3-075
EM-GJ3-090
EM-GJ3-115
EM-GJ3-132
EM-GJ3-160
EM-GJ3-185
EM-GJ3-200
EM-GJ3-250
EM-GJ3-280
EM-GJ3-320
EM-GJ3-355
EM-GJ3-400
EM-GJ3-450
EM-GJ3-500
EM-GJ3-600
EM-GJ4-5d5
EM-GJ4-7d5
EM-GJ4-011
EM-GJ4-015
EM-GJ4-018
EM-GJ4-022
EM-GJ4-030
EM-GJ4-037
EM-GJ4-045
EM-GJ4-055
EM-GJ4-075
EM-GJ4-090
EM-GJ4-115
EM-GJ4-132
EM-GJ4-160
EM-GJ4-185
EM-GJ4-200
EM-GJ4-250
EM-GJ4-280
EM-GJ4-320
EM-GJ4-355
EM-GJ4-400
EM-GJ4-450
EM-GJ4-500
EM-GJ4-600
–
–
EM-GJ2-5d5
EM-GJ2-7d5
–
EM-GJ2-011
EM-GJ2-015
EM-GJ2-018
EM-GJ2-022
EM-GJ2-030
EM-GJ2-037
EM-GJ2-045
EM-GJ2-055
–
EM-GJ2-075
EM-GJ2-090
EM-GJ2-100
EM-GJ2-115
EM-GJ2-132
EM-GJ2-160
EM-GJ2-185
EM-GJ2-200
EM-GJ2-220
EM-GJ2-250
EM-GJ2-315
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
115
132
160
185
200
250
280
320
355
400
450
500
600
5.5
7.5
11
15
22
30
37
45
55
75
90
115
132
160
185
200
250
280
320
355
400
450
500
600
5.5
7.5
11
15
22
30
37
45
55
75
90
115
132
160
185
200
250
220
18.5
–
–
–
18.5
–
100
315
11
15
23
30
37
43
60
75
90
110
150
180
230
264
320
370
400
500
560
640
710
800
900
1000
1200
C: Cabinet type
Product Series Option
146 270 160 131 247 M6
146 270 160 131 247 M6
146
146
146
146
146
146
146
146
146
270
270
270
270
270
270
270
270
270
160
160
160
160
160
160
160
160
160
131
131
131
131
131
131
131
131
131
247
247
247
247
247
247
247
247
247
M6
M6
M6
M6
M6
M6
M6
M6
M6
257 525 194 195 377 M8
257
257
257
257
257
525
525
525
525
525
194
194
194
194
194
195
195
195
195
195
377
377
377
377
377
M8
M8
M8
M8
M8
290 560 245 260 465 M8
290
290
290
560
560
560
245
245
245
260
260
260
465
465
465
M8
M8
M8
330 590 245 300 490 M8
330 590 245 300 490 M8
450 740 300 400 575 M10
450 740 300 400 575 M10
EM-GJC5d5-
EM-GJC5d7-
EM-GJC110-
EM-GJC510-
EM-GJC810-
EM-GJC220-
EM-GJC030-
EM-GJC730-
EM-GJC540-
EM-GJC550-
EM-GJC570-
EM-GJC090-
EM-GJC511-
EM-GJC231-
EM-GJC061-
EM-GJC581-
EM-GJC002-
EM-GJC052-
EM-GJC082-
EM-GJC023-
EM-GJC553-
EM-GJC004-
EM-GJC054-
EM-GJC005-
EM-GJC006-
1 Soft StarterSolution
1 2
Model Voltage(V) Power(KW) Current(A)
Model Voltage(V) Power(KW) Current(A)
EM9 G/P3 Series(Three phase to three phase 380V~460V)
90mm
11
5m
m
Suitable for : EM-GJ3-5d5 ~EM-GJ3-600
Bypass output Delay output Fault output Instant stop Stop Start Common DC4-20mA output
- +
>50 >50
>100
>100
>10
Air out
Air intake
By-pass output
Time-delayoutput
Failure output Instantaneous Stop Start-up Public
DC4-20mA output
- +
W1 D W2 d(Mount screw)
H1
H2
KM
Motor
Squirrel-cage 3-phase asynchronous motor
VU W 3 4 5 6 7 8 9 10 11 12
By-passcontanctors
Instantaneous Start-up PublicStop +-
DC 4 ~20mAanalog output
KM(By-pass contactor)
2FU
1 2L11 R L12 S L13 T
1FU
L1 L2 L3
QF(circuit breaker)
Time-delay output Failure outputSoft starter
Main circuit connection diagram
EM9 series frequency inverter is a brand-new vector high-performance frequency inverter. By decoupling control of motor magnetic flux current and torque current to achieve rapid-response and accurate torque control, can run a wide range of high-precision speed and torque control operation. Which is suitable to industrial automation the in every field.
1 2 3 4 5 6 7 8 9 10 11 12
Soft Starter 2 EM9 Series Vector Frequency Inverter
Product Introduction
Product Features
Input voltage range:220V/380V/480V/575V/690V ±15%.
Input frequency range:47~ 63Hz.
Output voltage range:0 ~ rated input voltage.
Output frequency range:0 ~ 600Hz.
Overload capacity: 60s with 150%of rated current, 10s with 180% of rated current.
Self study motor parameter function.
Control mode: Sensorless Vector Control (SVC);Constant Torque; V/F Control.
Speed accuracy: Sensorless Vector Control: ±0.5% of maximum speed (SVC).
Starting torque: 150% of rated torque at 0.5Hz (SVC).
Programmable timing running(Simple PLC).
In all model inverters integrated IGBT are used.
The malfunction ratio is 0.1% within 18 months warranty.
Model Introduction
EM9 - G 3 [C] - 015
EMHEATER EM9 series
frequency inverter
B: Ball millC: CNC machineE: Energy saving control cabinetH: Heavy loadG: General useP: Fan or PumpZ: Injection machine
Product Type
1: 1 PH 200~240V2: 3 PH 220~240V3: 3 PH 380~460V4: 3 PH 460~500V6: 3 PH 560~690V
Input Voltage
015: 15KW5d5: 5.5KW
C: Cabinet type
Product Series Option Adaptable Motor
EM9-G1-0d4
EM9-G1-d75
EM9 G1 Series(Single phase to three phase 200V~240V)
EM9-G1-1d5
EM9-G1-004
EM9-G1-7d5
EM9-G1-2d2
EM9-G1-5d5
EM9-G1-011
220
220
220
220
220
220
220
220
0.4 2.5
0.75
1.5
2.2
4
5.5
7.5
11
4
7
10
16
23
30
45
EM9 G/P3 Series(Three phase to three phase 380V~460V)
Model Voltage(V) Power(KW) Current(A)
EM9-G/P3-037
EM9-G/P3-055
EM9-G/P3-075
EM9-G/P3-132
EM9-G/P3-185
EM9-G/P3-220
EM9-G/P3-045
EM9-G/P3-090
EM9-G/P3-110
EM9-G/P3-160
EM9-G/P3-200
380
380
380
380
380
380
380
380
380
380
380
37
55
90
132
185
220
45
75
110
160
200
60
90
150
210
300
380
75
110
176
250
340
EM9-G3-d75
EM9-G/P3-1d5
EM9-G/P3-2d2
EM9-G/P3-5d5
EM9-G/P3-7d5
EM9-G/P3-004
EM9-G/P3-011
380
380
380
380
380
380
380
380
2.50.75
1.5
2.2
4
5.5
7.5
11
4
6
10
13
17
25
32EM9-G/P3-015
EM9-G/P3-022
EM9-G/P3-018
EM9-G/P3-030
380
380
15
30
18.5 37
45
EM9-G/P3-280
EM9-G/P3-350
EM9-G/P3-450
EM9-G/P3-560
EM9-G/P3-250
EM9-G/P3-315
EM9-G/P3-400
EM9-G/P3-500
EM9-G/P3-630
380
380
380
380
380
380
380
380
380
280
350
450
560
250
315
400
500
630
470
600
690
860
420
520
640
750
950
38022 1100
Keypad Size Installation Direction
3 4
Technical Characteristics
EM9 Series Vector Inverter
Input Single phase 220V, three phase 220V/380V/480V/690V ±15%, 47~ 63 Hz.
Maximum output voltage is same with input power.
100% continuous output
150% rated current 1 minute, 180% rated current 10 seconds.
Sensorless vector control, V/f control, Torque control optimization vector PWM.
Frequency (speed) input. Moment input. Location input.
Keypad. External terminal (2 line control. Three line control). RS485
Digital input. Analog input. Multiple speed. PID set. Serial communication RS485 setting, etc
0.00-600.00 Hz.
Digital: 0.01 Hz simulation: 0.05 Hz
0~3600s
0.5 K - 15.0 KHz
Single phase 220V, three phase 220V/380V/480V/690V ±15%, 47~ 63 Hz.
Automatic torque boost. Fixed torque boost curve, arbitrary V/f curve optional.
0.5 Hz / 150% rated torque.
1: 100(no sensor vector).
Plus or minus 0.5% maximum speed.
AVR function effectively, keep output voltage stable.
Automatic limit output current, avoid frequent over current trip.
Brake frequency: 0.1 ~ maximum frequency braking time 0 ~ 50 seconds brake current: 0 ~ 150% rated.
6 channels programmable terminal input.
AI1:0 ~ 10 V input, AI2:0 ~ 10 V or 0 to 20 mA input.
1 channel output.
1 channel output.
Two ways of output, 0/4 ~ 20 mA and 0 ~ 10 V.
LED digital tube display frequency converter of relevant information.
LCD liquid crystal display converter code information.
Can upload and download converter code information, realizing fast parameter copy.
Short circuit, the flow, overvoltage, undervoltage, lack of phase, overheating, external fault, communication malfunction,PID feedback fault, brake unit fault, the motor self learning problem and so on 25 studies fault protection.
Less than 1000 meters above sea level, clean, no oil mist, no corrosive gas, no direct sunlight
o o-10 C ~ +40 C, 20% ~ 90% RH (no frost).
Less than 0.5 g.
o o-25 C ~ +65 C.
Wall (0.75 KW ~ 132 KW), floor type electric control cabinet (160 ~ 400 KW).
IP20
Forced air cooling (controlled)
SpecificationItems
Maximum output voltage
Output feature
Over-load capacity
Control mode
Input mode
Operation mode
Frequency setting mode
Frequency control range
The resolution of the input frequency
Acc/ Dec time
Carrier frequency
Voltage/frequencycharacteristic
Torque boost
Start torque
Speed control ratio
Moment control accuracy
Output voltage adjustment
Current automatic limiter
DC brake
Programmable digital input
Programmable analog input
Open collector output
Relay output
Analog output
LED display
LCD display
Parameter copy
Protection function
Installation site
Applicable ambient
Vibrate
Storage ways
Installation ways
Protection level
Type of cooling
Output
Basic control function
Peripheral port function
Keyboard display
Protection
Use condition
~
~
3 phase power supply380V ± 15% 50/60Hz
Multifunction digital input 1
Multifunction digital input 2
Multifunction digital input 3
Multifunction digital input 4
Multifunction digital input 5
Multifunction digital input 6
DC Reactor(Power above 160KW built-in)
Brake unit
Brake resistorP
N
P
PB
P1 P N
R
S
T
U
V
W
A02
M
V IJ15
Jumper of voltageor current input
Analog output 0/4-20mA or 0-10V
GND
A01
GND
Analog output0-10V
X1
X2
X3
X4
X5
X6
Y1
COM
Y2
COM
Multifunction opencollector output
Multifunction opencollector output
458+ 458+
458- 458-
PE
RA
RB
RC{Relay output
0-10V0-4 - 20mA Main input
Frequency PID setting
COM
PE
24V
+10V power supplyfor frequency setting
AI1 multifunction s analog input
AI2
GND
PE
VS ISJ11
Jumper of voltageor current input
Inverter
PE
Wiring Connection Diagram
Keypad Dimension
Size Model
L1(mm) W1(mm) D1(mm) L2(mm) W2(mm)
Keypad(Under 11KW)
Keyboard(Above 15KW) 135.2
97.5 58
74.5 21.3
17
130.8
90
70.8
56.4
EM9 Series Vector Inverter
5 6
Rated input voltage
Model Voltage(V) Power(KW) Current(A)
Installation Dimension
120mm or aboveVentilate fan
50mm or above
120mm or above
Safe space and distance Installation of multiple inverter
Inverter
Inverter
0.75-11KW The dimension of the machine
15-132KW The dimension of the machine
160-630KW The dimension of the machine
Installation Direction
EM9 Series Vector Inverter
Rated Output Power(KW)
Input VoltageA
(mm)B
(mm)H
(mm)W
(mm)D
(mm)Installation Hole
(mm)
0.4~1.5
2.2
0.75~2.2
4~5.5
7.5
11~18.5
22~30
37~55
75~93
110~132
160~200
220~250
280~315
350~450
500~630
Single Phase 220V-15%~+15%
Three Phase 380V-15%~+15%
79
111.5
111.5
136.5
202.5
170
200
250
300
320
–
–
–
–
–
132 140 85 125 4
156.5 170
156.5 170
125
125
162
162
5
5
205 220 150 175 5
287.5 300 216 212 6
350
444
590
659
858
370
465
610
584
883.5
1400
1600
1700
1700
2200
274
300
360
424
504
574
760
850
850
1200
226
235
299
324
338
430
480
482
523
550
9
9
9
11
11
–
–
–
–
–
–
–
–
–
–
3 EM11 Series Vector Frequency Inverter
Product Introduction
EM11 series frequency inverter is based on the accurately understanding of EMHEATER for customer’s requirements, inheriting the consistent pursuit of EMHEATER for high-quality, high reliability. EM11 series frequency inverter will bring you a new using experience with its excellent performance and powerful features.
Product Features
EM11 is first class frequency inverter with very strong software and hardware.
It has servo drive feature, with perfect speed control mode, and excellent torque control mode.
It can save 2 group motor parameters , and can drive synchronous motor and asynchronous motor.
It has sensor-less vector control (SVC), vector control+ PG; V/F control and V/F separation control.
It has 49 kinds digital input functions and 38 kinds digital output functions.
It has S curve of acceleration and deceleration, user can self defined S curve turning time.
The IGBT carrier frequency can auto adjustment according to heatsink temperature.
35 kinds protection function, including auto detecting short circuit after power on.
Including textile swing frequency and skip frequency function, etc.
Overload Capacity:60s with 150% of rated current, 3s with 180% of rated current.
All model built-in RS485 card, and approved by CE.
Model Introduction
EM11 - G 3 [C] - 015
EMHEATER EM11 series
frequency inverter
G: General useH: Heavy load L: LiftP: Fan or PumpS: ServoT: Torque control
Product Type
1: 1 PH 200~240V2: 3 PH 220~240V3: 3 PH 380~460V4: 3 PH 460~500V6: 3 PH 560~690V
Input Voltage
015: 15KW5d5: 5.5KW
C: Cabinet typeE: Economy type
Product Series Option Adaptable Motor
EM11-G1-d75
EM11 G1/G2 Series(Single/Three phase to three phase 200V~240V)
EM11-G1-1d5
EM11-G1-2d2
220
220
220
0.75
1.5
2.2
4
7
9.6
EM9 G/P3 Series(Three phase to three phase 380V~460V)
Model Voltage(V) Power(KW) Current(A)
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
EM11-G2-d75
EM11-G2-1d5
EM11-G2-2d2
EM11-G2-5d5
EM11-G2-7d5
EM11-G2-004
EM11-G2-011
220
3.80.75
1.5
2.2
4
5.5
7.5
11
5.1
9
13
25
32
45
60EM11-G2-015
EM11-G2-022
EM11-G2-018
15
18.5 75
9122
220
220
220
220
220
220
220
220
220
EM11 G/P3 Series(Three phase to three phase 380V~460V)
EM11-G3-d75
EM11-G/P3-1d5
Model Voltage(V) Power(KW) Current(A)
EM11-G/P3-2d2
EM11-G/P3-5d5
EM11-G/P3-004
380
380
380
380
380
2.10.75
1.5
2.2
4
5.5
3.8
5.1
9
13
220
EM11-G2-030 30
EM11-G/P3-037
EM11-G/P3-055
EM11-G/P3-075
EM11-G/P3-132
EM11-G/P3-185
EM11-G/P3-220
EM11-G/P3-045
EM11-G/P3-090
EM11-G/P3-110
EM11-G/P3-160
EM11-G/P3-200
EM11-G/P3-030
EM11-G/P3-280
EM11-G/P3-350
EM11-G/P3-450
EM11-G/P3-250
EM11-G/P3-315
EM11-G/P3-400
37
55
90
132
185
220
45
75
110
160
200
30
280
350
450
250
315
400
60
91
150
210
304
377
75
112
176
253
340
465
585
725
426
520
650
820
EM11-G/P3-022
EM11-G/P3-018
EM11-G/P3-015
EM11-G/P3-011
EM11-G/P3-7d5
112
220EM11-G2-037 37 150
380
380
380
380
380
22
18
15
11
7.5
45
37
32
25
17
7 8
SpecificationItems SpecificationItems
Maximum frequency Vector control: 0~300Hz ; V/F control: 0~3000Hz
0.5~16KHz (The carrier frequency is automatically adjusted based on the load features.)
Digital setting: 0.01Hz; Analog setting: maximum frequency x 0.025%.
Sensor-less vector control(SFVC); Closed-loop vector control(CLVC); V/F control.
G type: 0.5Hz/150%(SFVC); 0Hz/180%(CLVC). P type: 0.5Hz/100%.
1:100(SFVC); 1:1000(CLVC); 1:50(V/F)
±0.5%(SFVC); ±0.02%(CLVC).
±10%(SFVC); ±5%(CLVC)
Automatic torque boost; Manual boost 0.1%~30.0%.
Straight-line V/F curve.Multi-point V/F curveN-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power)
Two types: complete separation; Half separation.
Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0s~6500.0s.
DC braking frequency: 0.00Hz~maximum frequency.Braking time: 0.0s~36.0s.Braking trigger current value: 0.0%~100.0%.
JOG frequency range: 0.00Hz~50.00Hz.JOG acceleration/deceleration time: 0.00s~6500.0s.
It realized closed loop control system easily.
It can keep constant output voltage automatically when the mains voltage fluctuation.
The current and voltage are limited automatically during the running process so as to avoid frequency tripping due to over voltage/ over current.
It can auto limit running current of frequency inverter to avoid frequency tripping.
(Excavator characteristics) It can limit the torque automatically and prevent frequency over current tripping during the running process. Torque control can be implemented in the VC mode.
The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time.
To avoid frequency over current faults of the frequency inverter.
Five groups of virtual DI/DO can realize simple logic control.
Time range: 0.0~6500.0 min
It supports communication bus via Modbus-RTU, PROFIBUS-DP, CANlink and CANopen.
Carrier frequency
Input frequency resolution
Control mode
Startup torque
Speed adjustable range
Speed stability accuracy
Torque control accuracy
Torque boost
V/F curve
V/F separation
Acceleration/Deceleration curve
DC braking
JOG control
Built-in PID
Auto voltage regulation(AVR)
Over voltage/Over current stall control
Rapid current limit function
Torque limit and control
High performance
Instant power off not stop
Rapid current limit
Virtual I/O
Timing control
Multiple communication protocols
Standard functions
Individualized functions
Technical Characteristics
G type: 60s for 150% of the rated current, 3s for 180% of the rated current.P type: 60s for 120% of the rated current, 3s for 150% of the rated current.
Overload capacity
It realizes up to 16 speeds via the simple PLC function or combination of DI terminal states.
Built-in simple PLC, multiple speeds
Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
The optional I/O extension card enables AI3 to receive the motor temperature sensor input(PT100, PT1000) so as to realize motor overheat protection.
It supports various encoders such as differential encoder, open-collector encoder, resolver, UVW encoder, and SIN/COS encoder.
It supports the operation of frequency inverter parameters and virtual oscillograph function, by which the state of frequency inverter can be monitored.
Key panel; Control terminals; Serial communication port; You can switch between these giving in various ways.
There are 10 kinds frequency giving; digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting.You can switch between these giving in various ways.
There are 10 kinds auxiliary frequency giving. It can implement tiny tuning of auxiliary frequency and frequency synthesis.
Motor overheat protection
Multiple encoder types
Advanced background software
Running command giving
Frequency giving
Auxiliary frequency giving
Two motors can be switched by two groups of motor parameters.Multi-motor switchover
Input terminal
Operation
Standard:6 digital input(DI) terminals, one of which supports up to 50Hz high-speed pulse input.2 analog input(AI) terminals, one of which supports 0~10V voltage input and the another supports 0~10V voltage input or 0~20mA current input expanding capacity:Many DI terminals. 1 AI terminal that supports -10V~10V voltage input.
It displays the parameters.
It is optional, supports panel display in Chinese or English language.
Optional LCD keypad can copy parameters.
It can lock the keys partially or completely and define the function range of some keys so as to prevent misoperation.
Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, over voltage protection, less voltage protection, overheat protection and overload protection, etc.
Less than 95% RH, without condensing.
LCD display
Parameters copy
Key locking and function selection
Protection mode
Humidity
o o o o-10 C ~ +40 C(De-rated if the ambient temperature is between 40 C and 50 C).Ambient temperature
Operation
Standard:1 high-speed pulse output terminal (open-collector) that supports 0~50Hz square wave signal output.1 digital output(DO) terminal.1 relay output terminal.2 analog output(AO) terminals, one of them supports 0~20mA current output or 0~10V voltage output expanding capacity:Many DO terminals.Many relay output terminals.
Output terminal
LED display
Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
Installation location
Lower than 1000m.Altitude
2Less than 5.9m/s (0.6G)o o-20 C ~ +60 C.
Vibration
Storage temperature
Display and keypad operation
Environment
EM11 Three phase 380V~690V inverter diagram
Breaker Contactor
EM11
10kΩ
Keypadinterface
( Switchable)
Analog input/Analog output/485 transform
R/L1
S/L2
T/L3
PB P+ P-
U/T1
V/T2
W/T3
DI1
DI2
DI3
DI4
DI5
HDI
FM
COM
DO1
CME
+10V
AI1
GND
DC 0~10VDC 0~20mAAI2
485+485-
J2 J8 J9 JP1
J6 J5 J4 J31
2
3
1
2
3
1
2
3
1
2
3
TA
TB
TC250V AC/1A 30V AC/1A
(DC 0~10V) AO2
GND
P
P
P
P
P
P
AO1
Three phase ACpower supply
Grounding
Multi-function input 1
Multi-function input 2
Multi-function input 3
Multi-function input 4
Multi-function input 5
Multi-function input 6
Multi-function output
Multi-function output
Analog input
Modbus communicationsRS485
Analog input reference voltage(DC 0~10V)
PG expansion card interface
Communications expansion
card interface
Function terminalexpansion card
interface
Shielded cable Twisted pair shielded cables
Relay output
Analog output 2
Analog output 1
Motor grounding
Externalbraking unit
External braking resistor
Main Circuit
Control Circuit
( Switchable)DC 0~10VDC 0~20mA
EM11 Series Vector Inverter EM11 Series Vector Inverter
9 10
The all digital AC servo driver adopt DSP+FPGA architecture to obtain fast data collection and processing, as well as high integration density and reliability. By using optimized PID control algorithm, accurate fully digital control of torque, speed and position have been achieved. With sufficient digital & analog interfaces, and output of position feedback pulse division and the zero pulse widening, variety of control device can be supported.
EMA Servo Driver
EMA 05 A WRated Output Power Power Voltage Encoder Type
EMB Servo Driver
EMB 15 A IRated Output Power Power Voltage Encoder Type
EMC Servo Driver
EMC 60 A IRated Output Power Power Voltage Encoder Type
EMD Servo Driver
EMD 1A B RRated Output Power Power Voltage Encoder Type
Keypad Dimension
EM11 Series Vector Inverter
Rated Output Power(KW)
Input VoltageW
(mm)W1
(mm)H
(mm)H1
(mm)D
(mm)Installation Hole
(mm)
0.4~1.5
0.75~4
5.5~7.5
11~15
18.5~30
37~45
55~75
90~110
132~200
220~280
315~400
Single Phase 220V-15%~+15%
Three Phase 380V-15%~+15%
83
160
220
290
320
410
420
560
720
66 166 152 118 Φ4.5
148 247 235 177 Φ5.5
126 349 334 194 Φ7
230
230
320
320
420
455
555
635
654
848
1018
440
540
610
630
820
980
218
240
239
303
403
403
Φ7
Φ10
Φ12
Φ12
Φ14
600 Φ14
EM11 G1/G3E series operating keypad diagram EM11 G3 series operating keypad diagram
Installation Dimension
0.4KW~15KW installation dimensions diagram
18.5KW~110KW installation dimensions diagram
CAUTIONRead the instruction manual
Disconnect power and ensure "ON" indicator
LED is off before performing inspection
or maintenance
2-dW1
W1
W
H1 H
M
RUNSTOP
RESET
DATAENTER
PROESC
Hz
KCLY KEYPAD
RUN DR LOCAL TRIP
2-Φd
D
D
132KW~450KW installation dimensions diagram
W
H
D W
H
D
Model W(mm) H(mm) D(mm)
G1/G3E series 59.0 99.0 16.0
Model W(mm) H(mm) D(mm)
G3/P3 series 69 93 17
Sign Specification
05 500W
08
10
800W
1000W
Sign SignSpecification Specification
A 220V
IIncremental
Encoder
WWire-saving
Encoder
Product Introduction
Specification Description
Sign Specification
15 1.5KW
25
30
2.5KW
3.0KW
Sign SignSpecification Specification
A 220V
AAbsoluteEncoder
IIncremental
Encoder
AAbsoluteEncoder
Sign Specification
6.0 6.0KW
Sign SignSpecification Specification
A 220V IIncremental
Encoder
B 380V
Sign Specification
1A 11KW
1E
1H
15KW
18KW
Sign SignSpecification Specification
B 380V R Resolver
2B 22KW
4 Servo Drive & Servo Motor11 12
118 106.5 185 175.5 157 Φ4.5
840 1129 1100 423720 Φ14
2.2 118 106.5 185 175.5 157 Φ4.5
CAUTIONRisk of injury and electric shock.
Wait 10 mins for capacitor discharge after
disconnecting power supply.
Read manual before installation.
Ensure proper earth connection.
M
RUNSTOP
RESET
DATAENTER
PROESC
Hz
KCLY KEYPAD
RUN DR LOCAL TRIP
Hz A V
REMOTE
TRIP
DIR
RUN
DATAENTER
PRGESC
RUN STO
P
RESET
Hz A V
REMOTE
TRIP
DIR
RUN
DATAENTER
PRGESC
RUN STO
P
RESET
PRG
ESCMF•K
RUN
QUICK
STOP
RESET
KEYPAD
Hz
RUN DIR LOCAL TRIP
PRG
ESCMF•K
RUN
QUICK
STOP
RESET
KEYPAD
Hz
RUN DIR LOCAL TRIP
Technical Characteristics
Items EMA
PowerSingle phase or Three phase AC 220V
(-15%~+10%, 50/60Hz)
Environment
Temperature
Humidity
Vibration
Operating emperature: 0~40 C; Storage emperature:-40~ 70o ot t C
o<90 C(Non-condensing)
2<0.5G(4.9m/s ) 10~60Hz(Non-continuous operation)
Control mode
(1) Position control mode(2) Speed control mode(External analog signal / internal parameters)(3) Torque control(4) Position&Speed hybrid control(5) Speed&Torque hybrid control(6) Torque&Position hybrid control
Regenerative brake Built-in Built-in or External
Feature
Speed frequency response
Speed fluctuation
Vibration
≥600Hz
Below 0.03%(Load fluctuation 0 ~ 100%, at rated speed)
1:5000
Input pulse frequency 0~500KHz
Regenerative brake
Programmable IO output:(1) Servo ready(2) Servo alarm(3) Position completed(4) Electromagnetism brake(5) Speed reached(6) Torque reached(7) Origin regression(DSZR) completed(8) Zero speed signal
Control output
Position control mode
Input pulse type
Electronic gear
Feedback pulse
(1) Pulse+direction; (2) CCW pulse/CW pulse; (3) Two-phase A/B quadrature pulse
Setting range: 1~65535/1~65535
Adjustable according to the encoder
Speed control mode(1) 8 steps internal speed settings(2) External analog signal(DC -10 ~ +10V)
Torque control mode(1) 4 steps internal torque setting(2) External analog signal(DC -10~ +10V)
Torque limited Function Torque limited range: -300 ~ +300%
Acc/Dec function Parameters setting: 1~10000ms (1~1000r/min or 1000~0r/min)
MonitoringMotor speed, Current position, Command pulse accumulation, Position deviation, Motor torque, Motor current, Rotor position, Command pulse frequency, Control mode, IO signals etc.
ProtectionOverspeed, overvoltage, undervoltage, overcurrent, overload, brake abnormal, encoder error, overheated, excessive position deviation, IPM temperature error, Input power phase loss, etc.
Display and operation 5/6-digit LED panel, 4 keys,2 LED lights, support shift operation
Communication CAN, RS232/RS485
(1) Servo enable (2) Alarm clearing(3) CCW drive forbidden(4) CW drive forbidden(5) Deviation counter clearing(6) Pulse command disenabled(7) Zero-speed clamp(8) CCW torque limitation(9) CW torque limitation(10) Control mode switch(11) Internal position selection 1(12) Internal position selection 2(13) Internal position selection 3(14) Internal speed selection 1
(15) Internal speed selection 2(16) Internal speed selection 3(17) Internal torque selection 1(18) Internal torque selection 2(19) Electronic gear ratio selection 1(20) Electronic gear ratio selection 2(21) Speed direction selection 1(22) Speed direction selection 2(23) Speed direction reverse(24) Emergency stopping(25) Launch the origin back(26) Origin back reference point(27) Internal position running startup signal
Servo Drive & Motor Servo Drive & Motor
13 14
EMB EMC
Three phase AC 220V/380V (-15%~+10, 50/60Hz)
External braking resistor (P+, PB);External braking unit (P+, (-))
Internal position mode 8 steps internal position command set by parameters
Motor speed, Current position, Command pulse accumulation, Position deviation, Motor torque, Motor current, Rotor position, Command pulse frequency, Control mode, IO signals, Drive temperature, Busbar voltage, etc.
Application load’s moment of inertia Less than 5 times of motor inertia Less than 3 times of motor inertia
Items EMD
Power Three phase AC 380V - 15%~+10%, 50/60Hz)(
Environment
Temperature
Humidity
Vibration
Operating emperature: 0~40 C( +40 C~+50 C, please derate it in use ); Storage emperature:-40~ 70o o o ot t C
o<90 C(Non-condensing)
2<0.5G(4.9m/s ) 10~60Hz(Non-continuous operation)
Control mode
(1) Position control mode(2) Speed control mode(External analog signal / internal parameters)(3) Torque control(4) Position&Speed hybrid control(5) Speed&Torque hybrid control(6) Torque&Position hybrid control(7) Pressure closed-loop control mode(8) Position closed-loop control mode
Regenerative brake External braking resistor (P+, PB); External braking unit (P+, (-))
Feature
Speed frequency response
Speed fluctuation
Vibration
≥300Hz
Below 0.03%(Load fluctuation 0 ~ 100%, at rated speed)
1:5000
Input pulse frequency Differential input: 0~500KHz; Open collector input: ≤200kpps
Regenerative brake
Programmable IO output:(1) Servo ready(2) Servo alarm(3) Position completed(4) Electromagnetism brake(5) Speed reached(6) Torque reached(7) Origin regression(DSZR) completed(8) Zero speed signal(9) Double-discharge plunger pump switch signal
Control output
Position control mode
Input pulse type
Electronic gear
Feedback pulse
(1) Pulse+direction; (2) CCW pulse/CW pulse; (3) Two-phase A/B quadrature pulse
Setting range: 1~65535/1~65535
Adjustable according to the encoder
Speed control mode(1) 8 steps internal speed settings(2) External analog signal(DC -10 ~ +10V)
Torque control mode(1) 4 steps internal torque setting(2) External analog signal(DC -10~ +10V)
Torque limited Function Torque limited range: -300 ~ +300%
Acc/Dec function Parameters setting: 1~10000ms (1~1000r/min or 1000~0r/min)
Monitoring
ProtectionOverspeed, overvoltage, undervoltage, overcurrent, overload, brake abnormal, encoder error, overheated, excessive position deviation, IPM temperature error, Input power phase loss, etc.
Display and operation 6-digit LED panel, 9 keys, 1 LED lights, support shift operation, user can freely define shortcut menu.
Communication CAN, RS232/RS485
(1) Servo enable (2) Alarm clearing(3) CCW drive forbidden(4) CW drive forbidden(5) Deviation counter clearing(6) Pulse command disenabled(7) Zero-speed clamp(8) CCW torque limitation(9) CW torque limitation(10) Control mode switch(11) Internal position selection 1(12) Internal position selection 2(13) Internal position selection 3(14) Internal speed selection 1
(15) Internal speed selection 2(16) Internal speed selection 3(17) Internal torque selection 1(18) Internal torque selection 2(19) Electronic gear ratio selection 1(20) Electronic gear ratio selection 2(21) Speed direction selection 1(22) Speed direction selection 2(23) Speed direction reverse(24) Emergency stopping(25) Launch the origin back(26) Origin back reference point(27) Internal position running startup signal(28) Oil pressure control PID parameter selection
Internal position mode 8 steps internal position command set by parameters
Motor speed, Current position, Command pulse accumulation, Position deviation, Motor torque, Motor current, Rotor position, Command pulse frequency, Control mode, IO signals, etc.
Application load’s moment of inertia Less than 2.5 times of motor inertia
Position closed- loop control
Pressure closed- loop control
The external coder or grating ruler can realize full-closed loop control of position
3 ways of external analog input (DC -10V~+10V)
60/80 Series servo motorThe max torque is up to 300% of rated torque.The max current is up to 300% of rated current.The max speed is up to 4500rpm.Be used to drive the feed shaft of various machineries.Various models (200W~1000W, with brake etc).Standard mounted wire-saving encoder 2500P/RStandard protection configuration is IP65.
Servo motor
The max torque is up to 300% of rated torque.The max current is up to 300% of rated current.The max speed is up to 3200rpm.Be used to drive the feed shaft of various machineries.Various models (1.0KW~3.1W, with brake etc).Standard mounted Incremental encoder 2500P/R.Optional absolute encoder 131072P/RStandard protection configuration is IP65.
180 Series servo motorThe max torque is up to 300% of rated torque.The max current is up to 300% of rated current.The max speed is up to 3000rpm.Be used to drive the feed shaft of various machineries.Various models (2.5KW~5.0KW, with brake etc).Standard mounted Incremental encoder 2500P/R. Standard protection configuration is IP65
220 Series servo motorThe max torque is up to 300% of rated torque.The max current is up to 300% of rated current.The max speed is up to 2250rpm.Be used to drive the feed shaft of various machineries.Various models (7.5KW~22.0KW, with brake etc).Standard mounted Resolver.Standard protection configuration is IP54
Specification Description
EMM - 60 S 006 A W 2 2
Product Series Motor SeriesDesigningSequence
Rated Torque Rated Speed Encorder Option parts Shaft end
W: Wire-saving Encoder 2500P/RA: Absolute Encoder 131072P/RI: Incremental Encoder 131072P/RR: Resolver
1: None2: With Oil Seal3: With Brake4: With Oil Seal, With brake.
1: Flat, Without keys (Standard)2: Flat, With keys, With Screw Thread
EMHEATER Servo motor
S: Standard (220V)E: Enhanced (380V)
006: 0.64N.m013: 1.27N.m016: 1.60N.m024: 2.40N.m032: 3.20N.m
A: 3000rmpB: 2500rmpC: 2000rmpD: 1500rmpE: 1000rmp
60/80 Series110/130 Series180 Series220 Series
Servo Motor Servo Drive
Series Speed(rmp) Power(KW) Model Single phase 220V Three phase 380V
60
3000
3000
80
110
130
180
220
0.20 EMM-60S006A EMA-05A[ ] –
0.40 EMM-60S013A EMA-05A[ ] –
3000
3000
3000
0.50
0.75
1.00
EMM-80S016A
EMM-80S024A
EMM-80S032A
EMA-08A[ ]
EMA-08A[ ]
EMA-10A[ ]
–
–
–
2500
2500
1.00
1.57
EMM-110S040B
EMM-110S060B
EMB-15A[ ]
EMB-15A[ ]
–
–
2500 1.00 EMM-130S040B EMB-15A[ ] –
2500
2500
1000
2500
2000
1000
2500
2000
1500
1000
2000
1500
1.30
1.57
0.63
1.96
1.57
0.79
2.60
2.10
1.57
1.00
3.10
2.35
EMM-130S050B
EMM-130S060B
EMM-130S060E
EMM-130S075B
EMM-130S075C
EMM-130S075E
EMM-130S100B
EMM-130S100C
EMM-130S100D
EMM-130S100E
EMM-130S150C
EMM-130S150D
EMB-15A[ ]
EMB-15A[ ]
EMA-10A[ ]
EMB-25A[ ]
EMB-25A[ ]
EMA-10A[ ]
EMB-30A[ ]
EMB-30A[ ]
EMB-25A[ ]
EMA-10A[ ]
EMB-30A[ ]
EMB-30A[ ]
–
–
–
–
–
–
–
–
–
–
–
–
2000
2000
2000
2000
1000
1000
1000
1000
3.00
4.00
5.00
6.00
2.50
3.00
4.00
5.00
EMM-180S[E]143C
EMM-180S[E]191C
EMM-180S[E]239C
EMM-180S[E]287C
EMM-180S[E]239E
EMM-180S[E]287E
EMM-180S[E]382E
EMM-180S[E]478E
EMC-60A[ ]
EMC-60A[ ]
EMC-60A[ ]
EMC-60A[ ]
EMC-60A[ ]
EMC-60A[ ]
EMC-60A[ ]
EMC-60A[ ]
EMC-60B[ ]
EMC-60B[ ]
EMC-60B[ ]
EMC-60B[ ]
EMC-60B[ ]
EMC-60B[ ]
EMC-60B[ ]
EMC-60B[ ]
Motor Adapter Table
1500 11.00 EMM-220E700D – EMD-1AB[ ]
2000 11.00 EMM-220E525C – EMD-1AB[ ]
1500 15.00 EMM-220E955D – EMD-1EB[ ]
1500 7.50 EMM-220E478D – EMD-1AB[ ]
2000 15.00 EMM-220E716C – EMD-1EB[ ]
2000 22.00 EMM-220E10EC – EMD-2BB[ ]
Servo Drive & Motor Servo Drive & Motor
110/130 Series servo motor
15 16
The function of input AC choke(reactor) matched with frequency inverter. Because frequency inverter often suffers from surge current and surge voltage impact, which will be seriously damaged performance and service life of frequency inverter and variable frequency drive. so there is requirement to add input reactor in front of the frequency inverter to boycott the surge voltage and surge current, protect the converter and debugger and prolong its service life and prevent harmonic interference. And because the frequency inverter is the variable frequency speed regulation way, so when frequency inverter works, it often produce high harmonic wave and produce waveform distortion, it will affect the normal equipment use, therefore, must add AC reactor at input/output side of frequency inverter , to short wavelengths, limits the harmonic voltage and harmonic current, and improve power quality.
The input and output AC choke of China EM technology limited uses the advanced technology by the high quality silicon steel and steel line. It has low temperature, low noise, simple operation and easy management characteristics.
EMHEATER AC choke can matched with all brand frequency inverter, such as Siemens, schneider, ABB, Vacon , Danfoss, Yaskawa, Fuji, Hitachi, mitsubishi and our own EM8, EM9, EM10 series frequency inverter.
Perfect solution products of EMI problem. Eliminate harmonic wave lower than 1%.
Excellent noise rejection.
Effectively reduce electromagnetic interfere of inverter.
Input filter is installed on the input side of the inverter.
Match with all kinds inverter for motor driving, elevators and other equipment .
Input filter is specially designed based on the frequency-domain characterization of inverter input interfering electric networking and other digital equipments.
Good performance of suppressing common mode and differential mode interference.
Suitable for the working place with strict requirement of circumstance. Suitable for the switching power supply, UPS, ATM, bill counter, embroidery machine, fuel dispenser, engraving machine, controller, industrial computer, scientific analysis instrument as well as the other electron equipments and inverter equipments.
1. Maximum operating voltage: 460VAC
2. Operating frequency: 0-120Hz
4. Hipot test voltage(one mimute)
P---E: 2700VDC
P---E: 2250VDC
5. Operating temperature: -25℃~+85℃
3. Switching frequency: 16KHz max
1. Maximum operating voltage: 460VAC
2. Operating frequency: 50/60Hz
3. Hipot test voltage(one mimute)
P---E: 2700VDC
P---E: 2250VDC
4. Operating temperature: -25℃~+85℃
5. Min. resistance: Line to Ground at 500VDC: 200MΩ
Input AC filter(Three phase)
Output AC filter(Three phase)
6. Min. resistance: Line to Ground at 500VDC: 200MΩ
Advantage Feature
Technical Data
1. Maximum operating voltage: 250VAC
2. Operating frequency: 50/60Hz
3. Hipot test voltage(one mimute)
P---E: 2000VDC
P---E: 1760VDC
5. Operating temperature: -25℃~+85℃
6. Min. resistance: Line to Ground at 500VDC: 200MΩ
4.Maximum leakage current: Line to Ground at 250VAC 50Hz: 0.3mA(10-20A);0.5mA(30-50A) 1.0mA(75-100A);0.002mA(B types)
Input AC filter(Single phase)Voltage(V) Power(KW) Current(A)
220
220EM-FIT1-1d5 1.5
0.75
7
4
Model
EM-FIT1-d75
220
220
220
220
220
220
EM-FIT1-004
EM-FIT1-7d5
EM-FIT1-015
4
7.5
15
2.2
5.5
11
16
30
55
10
25
42
EM-FIT1-2d2
EM-FIT1-5d5
EM-FIT1-011
Cx Cx Cx
Cy
Cx Cx Cx
Cy
Cx CxR R Cx R
L1
L2
L3
L '1
L '2
L '3
Output Filter
EM-FOT3-d75
EM-FIT3-1d5
Input Filter
EM-FIT3-d75
EM-FIT3-004
EM-FIT3-7d5
EM-FIT3-015
EM-FIT3-2d2
EM-FIT3-5d5
EM-FIT3-011
EM-FIT3-022
EM-FIT3-132
EM-FIT3-018
EM-FIT3-110
EM-FIT3-037
EM-FIT3-220
EM-FIT3-055
EM-FIT3-280
EM-FIT3-090
EM-FIT3-350
EM-FIT3-030
EM-FIT3-185
EM-FIT3-045
EM-FIT3-250
EM-FIT3-075
EM-FIT3-315
EM-FIT3-500
EM-FIT3-400
EM-FIT3-560
VoltageModel Power Current
(V) (KW) (A)
EM-FOT3-1d5
EM-FOT3-004
EM-FOT3-7d5
EM-FOT3-015
EM-FOT3-2d2
EM-FOT3-5d5
EM-FOT3-011
EM-FOT3-022
EM-FOT3-132
EM-FOT3-018
EM-FOT3-110
EM-FOT3-037
EM-FOT3-220
EM-FOT3-055
EM-FOT3-280
EM-FOT3-090
EM-FOT3-350
EM-FOT3-030
EM-FOT3-185
EM-FOT3-045
EM-FOT3-250
EM-FOT3-075
EM-FOT3-315
EM-FOT3-500
EM-FOT3-400
EM-FOT3-560
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
0.75
1.5
2.2
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
185
220
250
280
315
350
400
500
560
5
5
8
8
16
16
30
30
45
60
75
100
120
150
200
250
300
400
400
500
630
650
700
800
1000
1200
45
Product Introduction
Advantage Feature
Reducing working frequency inver ter and DC speed regulator interference to other devices, like harmonic interference, waveform distortion.
Enhance the capability of frequency inverter resistance to voltage unbalance degree. (Unbalance degree > 1.8% of rated voltage).
Protection frequency inverter rectifier modules and related components damage from pinnacle capacitive current due to low internal power resistance. (When power supply capacity is 5 times larger than frequency inverter capacity).
Improve the power factor of power supply, lower harmonic current content in the inverter power supply.
Reduce current and voltage waveform distortion rate, improve the quality of power supply.
Technical Data
1. Rated working voltage: AC 3/380V~480V.
2. Tolerance voltage test: 3.5KV, AC/50Hz/5mA/60s.
3. Application of frequency: 0~60Hz.
4. Power: 0.4~600KW.
5. Working noise: <55dB.
Input and Output AC Choke(Reactor)
6 Insulation resistance: 1000VDC: >100MOhm..
Reduce motor noise, eddy current losses and reduce motor temperature rise.
Lower current leakage resulting from higher harmonic wave, reduce RF
interference to peripheral equipment.
Smooth the inverter output voltage and current waveforms, reducing transient
voltage DV/DT impact on the motor insulation system, extending motor life
span.
Extend the effective distance between motor and inverter and reduce cable
capacitive current, protecting the inverter inside power switch components.
Input AC Choke(Reactor)
Output AC Choke(Reactor)
Output Choke
EM-RAO3-d75
EM-RAI3-1d5
Input Choke
EM-RAI3-d75
EM-RAI3-004
EM-RAI3-7d5
EM-RAI3-015
EM-RAI3-2d2
EM-RAI3-5d5
EM-RAI3-011
EM-RAI3-022
EM-RAI3-132
EM-RAI3-018
EM-RAI3-110
EM-RAI3-037
EM-RAI3-220
EM-RAI3-055
EM-RAI3-280
EM-RAI3-090
EM-RAI3-350
EM-RAI3-030
EM-RAI3-185
EM-RAI3-045
EM-RAI3-250
EM-RAI3-075
EM-RAI3-315
EM-RAI3-500
EM-RAI3-400
EM-RAI3-560
VoltageModel Power Current
(V) (KW) (A)
EM-RAO3-1d5
EM-RAO3-004
EM-RAO3-7d5
EM-RAO3-015
EM-RAO3-2d2
EM-RAO3-5d5
EM-RAO3-011
EM-RAO3-022
EM-RAO3-132
EM-RAO3-018
EM-RAO3-110
EM-RAO3-037
EM-RAO3-220
EM-RAO3-055
EM-RAO3-280
EM-RAO3-090
EM-RAO3-350
EM-RAO3-030
EM-RAO3-185
EM-RAO3-045
EM-RAO3-250
EM-RAO3-075
EM-RAO3-315
EM-RAO3-500
EM-RAO3-400
EM-RAO3-560
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
0.75
1.5
2.2
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
185
220
250
280
315
350
400
500
560
1.8
2.5
5
10
15
20
30
30
50
60
75
90
120
150
190
250
290
400
440
490
540
600
700
800
1000
1100
50
EM-RAI3-600 EM-RAO3-600 380 600 1250
6 Input & Output AC Choke(Reactor)5 Input & Output AC Filter17 18
Model Specific occasion Min. resistance( )Ω Rated Current(A) Peak Current(A) Match Inverter(KW)
The EM-SWF series sine wave filter adopting trait reactor, having professional filter capacitor and power resistor, reasonable structure, waveform distortion is small, small loss and low noise characteristics, can match with all brands frequency inverter and match many sets of machines, such as wind power, oil field, water and electricity, metallurgy, etc.
To converse SPWM voltage current waveform of frequency inverter to approximate sine wave waveform (For the line load feature, the COS is greater than 0. 3 and T H D is less than 5%).
Protect motor insulation system, reduce bearing current, prolong service life, reduce motor noise.
With general asynchronous motor can replace frequency induction motor use.
Effectively restrain the high frequency loss and RF radiat ion interference, in certain occasions without to use a shielded cable, lowering the field Cable requirements.
Cable between motor and frequency inverter can extend to 500 meters, the longest can reach 3000 meters above.
We have 220 V/380 V/440V/690V /1140V three phase variable frequency drive system.
Suitable motor and inverter power range: 0. 4KW - 1600 KW.
Suitable frequency inverter output carrier frequency range: 1.5 ~16 KHz.
Basic frequency range: 0 to 400 Hz (above 50Hz order must tell us when order).
Driving load forms: asynchronous motor (After special design can use for EPS \UPS and the surrounding power supply system).
Heat resistant level: F grade (for reactor part).
Protection level: IP 20.
EM-BU Dynamic Braking Unit is a high-performance braking product with Canada technology and has been applied extensively to elevator, crane, production machinery, mine hoist, centrifuger and oil pump in oil field, etc. EM-BU Dynamic Braking Unit is able to release the energy regenerated during motor speed regulation by brake resistance so as to produce enough braking torque to ensure normal operation of inverter and other devices.
Model Introduction:
Dc flat wave Choke (reactor) in the circuit is mainly used to improve the quality of power, increase power factor; Our company’s the DC flat wave reactor used high-quality international advanced cold rolled silicon steel sheet , specific volume small, low temperature, noise etc., DC specifications from 2 Amp to 10K Amp, voltage from 220V to 2000V; and we have huge amount inventory, welcome customers to inquire.
Product Introduction
Advantage Feature
Reduce the network current waveform distortion rate created by rectifier circuit of capacitance filtering.
To reduce and prevent for rectifier bridge damage and filter capacitor overheat by the pulse current impact in process of filtering capacitor charge and discharge.
Improve grid power factor, reduce total harmonic distortion, improve the quality of power supply of the power.
To improve or inhibit power grid voltage transient fluctuation caused by filter capacitor charging and discharging.
Technical Data
1. Rated working voltage: DC 500V ~ 700V
2. Switch Frequency: 0 ~ 18KHz
3. Motor Frequency: 0 ~ 200Hz
5. Working withstanding voltage: Iron core-coil 3000VAC/50HZ/5MA/60S No arcing breakdown discharge phenomenon(Factory tested).
4.Power: 0.4KW ~ 560KW
DC Choke(Reactor)
Model Voltage(V) Power(KW) Current(A)
DC500~700
EM-RAD3-5d5
EM-RAD3-011
EM-RAD3-015
EM-RAD3-030
EM-RAD3-045
EM-RAD3-075
EM-RAD3-7d5
EM-RAD3-018
EM-RAD3-022
EM-RAD3-037
EM-RAD3-055
EM-RAD3-004
EM-RAD3-110
EM-RAD3-160
EM-RAD3-200
EM-RAD3-090
EM-RAD3-132
EM-RAD3-185
5.5
11
18.5
30
45
75
7.5
15
22
37
55
4
110
160
200
90
132
185
11
20
35
50
80
120
16
30
42
68
100
190
300
400
165
250
350
440
EM-RAD3-2d2
EM-RAD3-1d5
EM-RAD3-d75
2.2
1.5
0.75
6
4.5
2.5
6. Insulation resistance: Iron core-coil 1000VDC is more than 100M.
7. Temperature limit: Core temperature not to exceed 70K (thermometer method), Coil temperature not to exceed 95 k (DC resistance method).
8. Working noise: less than 50DB(horizontal distance 1 meter to DC choke).
Model Information
EM-RAD3-220 220 480
EM-RAD3-250 250 550
EM-RAD3-280 280 600
EM-RAD3-315 315 700
EM-RAD3-355 355 800
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
DC500~700
Inductance(mH) @1KHz
6.3
3.6
1.9
1.08
0.7
0.45
4.4
2.1
1.33
0.8
0.54
0.33
0.22
0.14
0.36
0.26
0.17
0.12
11
15
28
0.10
0.094
0.090
0.074
0.064
EM-RAD3-400 400 900DC500~700 0.057
Sine Wave Filter
Advantage Feature
Brake Unit
Voltage(V) Power(KW) Current(A)
380
EM-SWF3-1d5 1.5
0.75
3.5
2.5
Model
EM-SWF3-d75
EM-SWF3-004
EM-SWF3-7d5
EM-SWF3-015
4
7.5
15
2.2
5.5
11
8.5
17
33
5
11
25
EM-SWF3-2d2
EM-SWF3-5d5
EM-SWF3-011
EM-SWF3-022 22
18.5
45
39EM-SWF3-018
EM-SWF3-037 37
30
75
60EM-SWF3-030
EM-SWF3-055
EM-SWF3-090
EM-SWF3-132
55
90
132
45
75
110
110
190
260
90
150
220
EM-SWF3-045
EM-SWF3-075
EM-SWF3-110
EM-SWF3-220 220
185
400
370EM-SWF3-185
EM-SWF3-280
EM-SWF3-350
EM-SWF3-500
280
350
500
250
315
400
630
500
700
1000
450
560
800
1300
EM-SWF3-250
EM-SWF3-315
EM-SWF3-400
EM-SWF3-630
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
380
EM-BU1
EM-BU3
EM-BU4H
EM-BU3HA
EM-BU2
EM-BU3H
EM-BU5H
EM-BU4HA
EM-BU5HA
Dynamic braking
Dynamic braking
Dynamic braking
With keypad dynamic braking
Dynamic braking
Dynamic braking
Dynamic braking
With keypad dynamic braking
With keypad dynamic braking
20
7
3.5
5
15
5
2.5
3.5
2.5
6 33 0.75~18.5
15 100 55~110
50 200 185~220
40 150 132~160
10 50 22~45
40 150 132~160
60 300 250~315
50 200 185~220
60 300 250~315
8 Sine Wave Filter & Brake Unit7 DC Choke(Reactor)19 20
Matched Inverter(KW)
Multi-terminal and multi-resistance,fixed ,adjustable are available ,out wire's length are available following customer requirement, special terminals are available for unusual applications.
Element consisting of a wave-shaped alloy ribbon or non-wave shaped alloy wire.
Good dissipation ,high stability, high power rating, high over load and long life.
Conforms to the ROHS standard and the LEAD-FREE non-lead standard.
Durable, vibration-proof, dissipates heat well and low temperature coefficient with resistance varying in direct proportion.
EMZ series successfully applied for national patent (ZL2004300866567).
Specification: 80W60R, 80W100R, 80W20R, 100W20R, 100W100R, 120W68R, 150W20R, 200W20R, 200W200R, 300W20R, 300W150R, 300W200R, 400W150R, 400W20R, 500W100R, 500W20R, 800W75R 1040W50R, 1040W75R etc.
Conforms to the ROHS standard and the LEAD-FREE non-lead standard.
The product is easy to utilize and install, and suitable for a wide range applications. Applications include industrial machinery, load testing, electric power distribution, instruments, and automated control installations.
DR series is suitable for educational modeling applications, load testing ,industrial machinery, electric power distribution ,instruments , automation control installations ,lift trucks ,overhead cranes, elevators, arc and spot welders ,battery chargers ,machine tools ,conveyors, and UPS systems.
Brake Resistor
Application
Aluminum Resistor
Application
Brake System
Brake Unit
SpecificationsModel
Brake Resistor
QTY(Pcs) Specifications QTY(Pcs)
0.75
1.5
2.2
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
185
200
220
250
280
315
355
400
500
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU1
EM-BU2
EM-BU2
EM-BU2
EM-BU3
EM-BU3
EM-BU3
EM-BU3
EM-BU3H
EM-BU3H
EM-BU4H
EM-BU4H
EM-BU4H
EM-BU5H
EM-BU5H
EM-BU5H
EM-BU4H
EM-BU4H
EM-BU4H
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as standard
Built-in as option
Built-in as option
Built-in as option
Built-in as option
Built-in as option
Built-in as option
External
External
External
External
External
External
External
External
External
External
External
External
External
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
100W/500Ω
300W/400Ω
500W/250Ω
800W/150Ω
1200W/100Ω
1600W/75Ω
2000W/60Ω
3000W/50Ω
3000W/30Ω
3000W/30Ω
5000W/20Ω
5000W/20Ω
10000W/8Ω
10000W/8Ω
12000W/6.8Ω
12000W/6.8Ω
12000W/6.8Ω
12000W/6.8Ω
12000W/6.8Ω
12000W/6.8Ω
30000W/4Ω
30000W/4Ω
40000W/3Ω
40000W/3Ω
40000W/3Ω
50000W/2.5Ω
70000W/2Ω
70000W/2Ω
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
Cabinet
Cabinet
Cabinet
Cabinet
Cabinet
Cabinet
Cabinet
Cabinet
9 Brake Resistor & Aluminum Resistor 10 Production Process21 22
The goods
Retreat goods
Material purchase
Special mining whether
IQC inspection
Inspectionanomaly
Material warehousing
Qualified
Qualified
Normal
QualifiedYes
Hair outsourcing electronic devices
Outsourcing processing
Three processingPlate parts material
scrapped
Bad
BadBad
Bad
BadNormal
PQC inspection
Yes
No
Yes
NO
Disbursement
FQC inspection
PQC inspectionAging 48 hours
FQC inspectionwarehousing
Normal
The bad
Yes
NoQualified
Qualified
BadNormal
Electronicafter welding
Electronictesting
Plate partsmaintenance
The assembly
11 Application
Stone, brick and wood
Printing/Packaging Machine
Machine tool
Plastics processing / Extrusion processing
Textile industry
Lifting equipment
Fan&Water Pump/Air compressor
Other applications
Industrial washing machine: Many brands supporting, large power washing, high speed dehydration stable.
Centrifuge: Large torque, fast acceleration and deceleration, applicable in harsh environments.
Musical Fountain: Large starting torque, current limit function, do not trip.
Mechanical vibrator: Fast acceleration and deceleration performance, excellent feature for motor forward and reverse control.
(etc.)
Standard inverter cabinet with injection molding signal card.
Energy saving cabinet built in inverter and bypass.
Built in charging function to support mode of contract saving energy.
Extrusion force is big, Avoid tripping, uniform extruding flow.
Quick ly and s t rong fo rce ou tpu t , Mul t ip l e pumps have good synchronization performance.
High energy-saving rate, with conversion of inverter and grid power.
Stable and reliable operation, with mechanical brake to realize halfway stop and start.
Compatible with YASKAWA independent protocol.
Wide operating voltage, low-voltage power shake can work continuously, strong environmental adaptability.
Multi-speed synchronous transmission performance is good; low-speed with large torque has heavy load capacity.
Large lifting torque, energy-saving.
high starting torque, adapt to wide voltage fluctuation.
Airtight structure can avoid air duct blocked, Wobble function.
built in working records and techniques' curve.
Built-in closed loop, realized high precision synchronous.
Fixed-length function.
Realized permanent magnet synchronous motor open loop control.
Support built-in Speed tracking card.
Built -in Pressure closed loop and dormancy awakening, protection function of over pressure.
Built -in extension water supply card, realized one drive for multiple pumps with clock function.
Realized thermostatic control, high Energy-saving rate.
Small volume and high efficiency, frequency inverter and air compressor be used cooperatively.
Operating frequency can be up to 3000 Hz, suitable for drilling machine and carving and milling machine.
Big cutting forces, steady speed and high precision.
Can stable operation at high speed.
Terminal RS485 support 500k communication rate.
Various vector control can be applied to all kinds of machine tools.
Have wire breakage alarm, automatic shutdown, rocker, floating roller once in place.
Super performance of fast acceleration and deceleration, ensure product consistency.
Reciprocating acceleration and deceleration used short time, precise positioning.
High Stability torque control mode makes stable rewinding.
Energy saving, big torque quickly move up and down.
Torque current control uniform cutting and big torque with low speed.
Start and stop quickly, built-in crafts control.
Steady speed with high accuracy and big torque, high yield of production ratio.
23