20
Confidential & Proprietary 1 Extending furnace run length and coil life through decoke procedure & optimization by Vinodkumar Mishra, Ingenero, Mumbai, MH, India EMET 2014 Conference October 21st, 2014

EMET paper on Decoke procedure [Compatibility Mode]

Embed Size (px)

Citation preview

Page 1: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary1

Extending furnace run length and coil life through decoke procedure & optimization

by

Vinodkumar Mishra, Ingenero, Mumbai, MH, India

EMET 2014 Conference

October 21st, 2014

Page 2: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary2

Presentation Outline

• Introduction

• Need For Decoke Modification

• Basis for Decoke Modification

• Methodology Adopted

• Case Study – Ethylene Plant

• Conclusion

• Q&A

Page 3: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary3

Introduction

• Ethylene is produced by thermal cracking of hydrocarbons (Ethane/Propane/Naphtha etc.) in radiant coils of furnace section

• Furnace effluents from radiant coils are immediately quenched in transfer line exchangers (PTLE*, STLE, TTLE etc.) to arrest the chain reaction avoiding secondary reaction

• During normal operation, coke slowly deposits in the radiant coils and transfer line exchanger tubes

* Primary Transfer Line Exchanger (PTLE), Secondary Transfer Line Exchanger (STLE), Tertiary Transfer Line Exchanger, etc.

Coke deposition in furnace coils is inherent to the process

Page 4: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary4

Effect of Coke Deposition

• Reduced heat transfer to the process fluid resulting high TMT (tube metal temperature) � shut down to prevent tube failure

• Increased pressure drop, and eventually plugged coils in extreme case.

• High PTLE outlet temperature exceeding design limit of downstream piping � shut down to protect piping

• Reduction in furnace run-length and feed throughput in furnaces as ability to reach required temperatures in process fluid cannot be achieved safely

Coke deposition limits production

Page 5: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary5

Furnace Operating Parameters

To get desired yield from the cracking furnaces, operating parameters are continuously measured and monitored

• Feed rate and composition � determines appropriate operational settings

• Coil pressure ratio(CPR) � one variable determining need for decoking

• Coil outlet temperature(COT) � one variable determining need for decoking

• Hydrocarbon to Dilution steam ratio(HC/DS) � helps optimize throughput and cracking severity

• Transfer line exchangers outlet temperature and pressure � one variable determining need for decoking

Page 6: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary6

Decoke Operation

Furnace Run-length terminating criteria:

•CPR reached to 0.9

•Maximum TMT of any coil reached to the design limit of coil metallurgy (1050 ºC)

•Maximum TLE outlet temperature limit of D/S piping

Furnace operation is typically terminated and decoking done when specific criteria is reached

Page 7: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary7

Need for Decoke Modification

Generally manufacturing takes between 16 to 32 hours depending on the decoking procedure

•Rigorous decoking (high air and steam flows and COT) to burn the coke inside radiant coils and TLE exchangers – Upside is the speed of 16 hours but the downside is potential coil damage

•Mild decoking (low air and steam flows and COT) for extended period –Upside is less metallurgical damage but downside is the increased time of nearly 32 hours resulting in increased production loss and energy usage

Decoking procedures differ; getting it wrong is expensive

Page 8: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary8

Basis for Decoke Modification

Operational and decoking parameters to trend include:

• Coking rate in Radiant coil

• Rate of rise in TLE outlet temperature

• Fouling rate in TLE

• TMT of individual Radiant coils associated with respective TLE

• COT of individual Radiant coil

• Excess CO2 during decoke steps

• Gas velocity during decoke steps

• Dilution steam to Air ratio during decoke operation

• Physical observation status of radiant coils during Furnace cracking and decoke operation

A holistic and scientific approach should be used to develop a specific decoke procedure for every Ethylene plant based on furnace type, feed, severity and TLE fouling

Page 9: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary9

Methodology Adopted

Ingenero combines best of breed technology into a single software tool for Ethylene producers for this purpose and other optimization

Sample Software Combined and/or results utilized:Furnace Side / Hot Side

• Convection section modeling (e.g. FRNC 5)

• CFD

• Fire Box Modeling (geometry / heat flux models)

• Yield models

• ANN

• LP Model

Recovery / Cold Side

• Steady State Simulation

• Pinch

• FN Pro 2

Page 10: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary10

Fire box (geometry / heat flux) models allows individual burner management

= Fully open valve =Partially shut valve =Primary fuel line =Secondary fuel line=Low capacity burner = High capacity burnerBURNER BURNER

BURNER BURNER BURNER BURNER BURNER BURNER BURNER BURNER

Coils 1 to 8 Coils 9 to 16 Coils 17 to 24 Coils 25 to 32

Burner Adjustment for Controlling TMT

Page 11: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary11

Actual

Colour Code for valuesDesign Simulated

FRNC to Monitor Convection Section

Page 12: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary12

Methodology Adopted

• Deviations of individual coil CPR, TMT and TLE outlet temperatures are tracked and trended for individual furnaces for daily review and analysis

• Analysis of furnace parameters, Feed trims, COT trims and Burner management provides daily guidance to control CPR and TMT of coils as well as TLE outlet temperatures

• Fouling trends of individual radiant coil and TLE in the furnace from HTRI/ HTFS software is incorporated into the daily output

• With historical analysis and predictive modeling, the appropriate decoke steps and modifications in decoke procedure are achieved

Specifically for decoking optimization those key operational and decoking parameters are analyzed

Page 13: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary13

Case Study

Software allows deviation of furnace radiant coils CPR to be controlled through management of burner and other furnace operating parameters to minimize coking

CPR deviation trends of Furnaces

Delta Average CPR

-0.10

-0.09

-0.08

-0.07

-0.06

-0.05

-0.04

-0.03

-0.02

-0.01

0.00

0.01

0.02

0.03

0.04

0.05

0.06

0.07

0.08

0.09

0.10

1-Dec 11-Dec 21-Dec 31-Dec 10-Jan 20-Jan 30-Jan 9-Feb 19-Feb 1-Mar 11-Mar 21-Mar 31-Mar 10-Apr 20-Apr 30-Apr

FURNACE 1 FURNACE 2 FURNACE 3 FURNACE 5

Increase in CPR deviation

CPR deviation reduction after operation optimization

Page 14: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary14

Case Study

TLE fouling is reduced by modifying Decoke procedure

TLE fouling trends before and after Decoke procedure modifications

TLE fouling trends

0

0.0002

0.0004

0.0006

0.0008

0.001

0.0012

0.0014

0.0016

0.0018

17-Jun-07 22-Feb-08 29-Oct-08 06-Jul-09 13-Mar-10 18-Nov-10 26-Jul-11 01-Apr-12

PTLE-1 PTLE-2 PTLE-3 PTLE-4 PTLE-5 PTLE-6

Before decoke procedure modification

After decoke procedure modification

Page 15: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary15

33

55

110

0

20

40

60

80

100

120

Original Design Achieved

Furnace Run-lengthTi

me

(Day

s)

Case Study: Improve Furnace Run-length

Run length met design quickly and then was greatly exceeded

Page 16: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary16

Impact on Plant Performance

� Yield improved about 3% from 76.6% by Decoke procedure modification & optimization

�Reduction in no of Decoke cycle

� Increase in furnace yield with increased feed rate

�Delimiting PTLE max design o/l temperature by Decoke procedure modification

Year 2004 2005 2006 2007 2008 2009 2010 2011

Net Ethylene Made (Tons) 386,000 437,000 565,709 531,99 6 500,466 577,772 538,069 551,112

Feed Processed (Tons) excl. CH4 504,000 548,000 702,226 670,034 621,904 722,327 680,342 696,515

% Yield 76.6% 79.7% 80.6% 79.4% 80.5% 80.0% 79.1% 79.1%

% Yield Improvement - 3.1% 4.0% 2.8% 3.9% 3.4% 2.5% 2.5%

Improvement due to Yield (Tons)

- 16,988 27,893 18,835 24,167 24,562 17,013 17,670

Page 17: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary17

Conclusion

Applying a systematic and careful analysis of decoking process and variables associated with coking can have dramatic effects

Example Client:

• Furnace run length improvement (33 days to 105 days)

• Delimited TLE maximum outlet temperature

• 3 Furnace decoke operations were avoided during the year.

• Equivalent to extra Ethylene production 1055 tons

• Other intangible benefits - Increased Furnace Coil life/ reliability due to reduction in decoke cycle

• Energy saving due to reduced decoke cycle

• Prediction and planning for mechanical cleaning of TLE

Page 18: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary 18

Page 19: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary19

Ingenero – Team Member’s Profile

Vinod Mishra

• Assistant General Manager – Process Technology

• Leads Ethylene plant support teams implementing and supporting technology and training for major Ethylene Producers

• Over 24 yrs work experience in Ethylene and Petroche mical Plant Operations and Technical Services for Reliance

• B.Tech. Chemical Engineer

• E mail: [email protected]

Page 20: EMET paper on Decoke procedure [Compatibility Mode]

Confidential & Proprietary20

Questions