Upload
others
View
14
Download
0
Embed Size (px)
Citation preview
AH 2.46 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityInformation
2
Emergency exit device EN 179
Panic exit device EN 1125
The standard cover devices to be used in
emergency situations if people are familiar with
the emergency exit and whose hardware. In this
situation a panic is most unlikely to develop. Lever
handle operated escape mortise locks or push
pads may used therefore.
The standard cover devices to be used in panic
situations if people are not familiar with the
emergency exit and whose hardware but must be
able to open the hardware intuitive. An horizontal
operated touch bar is here required.
AH 2.47New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
PED 100 Accessories
PED 100 Panic exit device
• Area of application: For fire resistant doors• Material: Touchbar mechanism: Steel• Colour: Touchbar mechanism: Black• Finish: Touchbar mechanism: Powder coated• Version: With cylinder aperture• Standard: EN 1125 in conjunction with approved accessories• For door width: <1400 mm• Door weight: <200 kg• Backset A: 65 mm• Distance B: 72 mm• Lever follower: 9 mm
Material Finish Colour Cat. No.
Bar: Steel Powder coated Bar: Red 901.02.439
Bar: Stainless steel Matt – 903.03.010
In compliance with EN 1125
Lever handle For outer side
Knob For outer side
• Area of application: Suitable for PED 100• Colour: Black
Cat. No.
Lever handle 911.52.126
• Area of application: Suitable for PED 100• Colour: Black
Cat. No.
Knob 911.52.127
AH 2.48 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
PED 210 Panic exit device
PED 200 Panic exit device With key action
• Area of application: For fire resistant doors• Material: Touchbar mechanism: Steel• Colour: Cover: Black• Finish: Touchbar mechanism: Powder coated• Version: Basic module• Standard: EN 1125 in conjunction with approved accessories• For door width: <1300 mm• Door weight: <200 kg• Lever follower: 8 mm
MaterialChất liệu
FinishMàu hoàn thiện
ColourMàu sắc
Cat. No.Mã số
Bar: SteelThanh: Thép
Powder coated Bar: Red 901.02.449
Bar: Stainless steelThanh: Inox
Matt – 903.03.014
Vertical locking action, with key change
• Area of application: For fire resistant doors• Material: Touchbar mechanism: Steel• Colour: Cover: Black• Finish: Touchbar mechanism: Powder coated• Version: Basic module with vertical locking action• Standard: EN 1125 in conjunction with approved accessories• For door height: <2400 mm• For door width: <1300 mm• Door weight: <200 kg• Lever follower: 8 mm
Material Finish Colour Cat. No.Bar: Steel Powder coated Bar: Red 901.02.459Bar: Stainless steel Matt – 903.03.016
AH 2.49New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
PED 200 and PED 210 Accessories In compliance with EN 1125
Lever handle For outer side
Knob For outer side
Dogging device
Micro switch
Order referenceSpindle supplied.42
45
36
5413
6
• Area of application: Suitable for PED 200 and PED 210• Colour: Black
Cat. No.
Knob 911.52.127
• Area of application: Retrofitting the "permanent open function" on panic doors, suitable for PED 200 and PED 210
Cat. No.
Dogging device 909.09.907
• Area of application: Acoustic alarm generator activates an alarm when panic doors are operated, suitable for PED 200 and PED 210
Micro switch 909.09.908
Order referenceSpindle supplied.
42
69
36118
5413
6
• Area of application: Suitable for PED 200 and PED 210• Colour: Black
Cat. No.
Lever handle 911.52.126
Cat. No.
AH 2.50 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Intumescent seal For fire resistant and smoke control doors
Top keep For aluminium doors
Top keep For plastic doors
• Area of application: Fire resistant and smoke control doors• Material: Graphite
Cat. No.
Seal 901.02.393
• Area of application: For top shoot bolt, on aluminium doors
Keep 911.52.116
• Area of application: For top shoot bolt, on plastic doors
Keep 911.52.117
Cat. No.
Cat. No.
AH 2.51New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Mounting sets overview For glass door installation
For the installation on glass doors, mounting sets are available to suit the modular panic exit devices.
X = One set from A, B or C is required. XX = Two sets from A, B or C are required.O = One set each is required.
Glass preparation details
Mounting options
Necessary glass preparation
3.1, 4
1.1,2, 3.1, 3.2,4
1.1,2, 3.1, 4
1.1,1.2, 2,3.1, 4
1.1,1.2,2, 3.1, 3.2,4
1.1,2, 3.1, 3.2, 4
1.1, 1.2, 2, 3.1, 3.2, 4
AFor mounting blank escutcheons on glass doors
X X X X X XX XX
BFor glass door installation, DIN left
X X X X X XX XX
CFor glass door installation, DIN right
X X X X X XX XX
DFor mounting shoot bolts on glass doors
O O O O O
EFor glass installation, central lock
OOOO
FFor glass installation, top lock
OOO
GFor shoot bolt
O O O O O
AH 2.52 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Mounting set A For mounting blank escutcheons on glass doors
Mounting set B For glass door installation, DIN left
Mounting set For glass door installation, DIN right
Mounting set D For mounting shoot bolts on glass doors
17
814
511
913
9 37
q9 • Area of application: For installation on glass doors
• Material: Aluminium• Colour: Stainless steel coloured• Finish: PVD• Version: Modular system
Cat. No.
Mounting set A 909.09.900
17
8
q9
5
170
119
36
9
46
17
8
145
119
13
9 37
q9
• Area of application: For installation on glass doors• Material: Aluminium• Colour: Stainless steel coloured• Finish: PVD• Version: Modular system
Mounting set B 909.09.901
17
8
145
119
13
9 37
q9
17
8
q9
5
170
119
36
9
46
• Area of application: For installation on glass doors• Material: Aluminium• Colour: Stainless steel coloured• Finish: PVD• Version: Modular system
Mounting set C 909.09.902
17
8
80 4810
9 29
q9
• Area of application: For installation on glass doors• Material: Aluminium• Colour: Stainless steel coloured• Finish: PVD• Version: Modular system
Mounting set D 909.09.903
Cat. No.
Cat. No.
Cat. No.
AH 2.53New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Mounting set EFor glass installation, central lock
Mounting set G
For shoot bolt
Accessories for glass installation PED 200 and PED 210
Lever handle For outer side of glass doors
• Area of application: For installation on glass doors• Material: Aluminium• Colour: Stainless steel coloured• Finish: PVD• Version: Modular system
Cat. No.Mounting set E 909.09.90417
8 728
50 3010
9
4149
13
50 3010
35
q9
• Area of application: For installation on glass doors• Material: Stainless steel• Version: Modular system
Cat. No.Mounting set G 909.09.906
• Area of application: Suitable for PED 200 and PED 210 on glass doors
• Colour: Black
Cat. No.Lever handle 911.52.122
Mounting set F For glass installation, top lock
28 17
9
27
1311
33.5
• Area of application: For installation on glass doors• Material: Aluminium• Colour: Stainless steel coloured• Finish: PVD• Version: Modular system
Cat. No.Mounting set F 909.09.905
AH 2.54 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
max. door leaf height b
max. door leaf width a
Installation in rebated doors
Installation in flush doors
A - Basic unit 1: Panic lock
B - Basic unit 2: Lever handle
C - Basic unit 3: Single profile cylinder
D - Basic unit 4: Latch parts and vertical
rod type touchbar
Features
• For rebated or flush doors
• For 1-leaf and 2-leaf doors
• For timber or steel doors
• Suitable for application in escape and rescue routes
• Suitable for DIN left and right hand
• Certified according to EN 1125, Classification 3-7-5-1-1-3-2-2-A
• The length of the touchbar must be at least 60 % of the
effective door opening
• Suitable for door leaf width (a) up to 1500 mm
• Suitable for door leaf height (b) up to 2650 mm
Function
• Locking function:
Lever handle (basic unit 2) can be locked by single
profile cylinder (basic unit 3): access not possible from the outside
• Opening of the door from the inside by pushing the touchbar
• Opening the door from the outside optionally possible by lever
handle or by lever handle and single profile cylinder
Note
• Basic unit 1 does not work with basic unit 3 alone:
Single profile cylinders
• Basic unit 1 works with
- Basic unit 2: Lever handle only
- Basic unit 2: Lever handle +
- Basic unit 3: Single profile cylinder
Panic exit device
AH 2.55New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Locking version for single leaf doors
Inside Basic unit 1 + touchbar (order separately)
Outside –
Locking version 1
Inside Basic unit 1 + touchbar (order separately)
Outside Basic unit 2
Locking version 2
Inside Basic unit 1 + touchbar (order separately)
Outside Basic unit 2
Basic unit 3 + cylinder rosette (order separately)
Locking version 3
Inside Basic unit 1 + touchbar (order separately)
Basic unit 4
Outside –
Locking version 4
Inside Basic unit 1 + touchbar (order separately)
Basic unit 4
Outside Basic unit 2
Basic unit 3 + cylinder rosette (order separately)
Locking version 5
Basic unit 1+2+3+4
Basic unit 1+4
Basic unit 1
Basic unit 1+2
Basic unit 1+2+3
AH 2.56 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Locking version for double leaf doors
Inactive leaf
Basic unit 1+4
Locking version 6
Inactive leaf Active leaf
Inside Basic unit 1 + touchbar (order separately)
Basic unit 1 + touchbar (order separately)
Basic unit 4 –
Outside – –
Active leaf
Basic unit 1
Locking version 7
Inactive leaf Active leaf
Inside Basic unit 1 + touchbar (order separately)
Basic unit 1 + touchbar (order separately)
Basic unit 4 –
Outside – Basic unit 2
Inactive leaf
Basic unit 1+4
Active leaf
Basic unit 1+2
Inactive leaf
Basic unit 1+4
Active leaf
Basic unit 1
Locking version 8
Inactive leaf Active leaf
Inside Basic unit 1 + touchbar (order separately
Basic unit 1 + touchbar (order separately)
Basic unit 4 –
Outside – Basic unit 2
– Basic unit 3 + cylinder rosette(order separately)
AH 2.57New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Base unit 1: Panic lock
Features
• For timber or steel doors
• For rebated or flush doors
• Suitable for application in escape and rescue routes
• Suitable for DIN left and right hand
• Prepared for single profile cylinder
• Certified according to EN 1125:97
Technical data
• Lever follower: - 8 mm
• Distance (b): 50 mm
Supplied with
2 Striking plates
1 Set of fixing material
1 Set of installation instructions
Switching DIN left/right hand and locking the latch
Housing Steel grey lacquered
Internal housing Steel yellow chromatized
Latch Stainless steel
Lever follower Zinc alloy
Cat. No. 911.52.272
5
AH 2.58 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Touchbar
Basic unit 2: Lever handle
Features
• Suitable for basic unit 1: Panic lock
Technical data
Diameter: 25 mm
Features
• Lever handle aperture part with rosette and square spindle
Technical data
Square spindle: - 8 mm
Supplied with
Fixing material
Finish 1000 mm 1200 mm 1500 mm
Stainless steel matt 911.52.279 911.52.280 911.52.281
Lever handle aperture part Zinc alloy grey lacquered
Rosette Plastic grey
Square spindle Zinc yellow chromatized
Cat. No. 911.52.287
AH 2.59New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Basic unit 3: Single profile cylinder
Cylinder rosette
Features
• Suitable for basic unit 1: Panic lock
• Only in connection with basic unit 2: Lever handle insertable
• With 5 pin tumblers
• Follower adjustable to 8 positions
• Single profile cylinder: Brass nickel plated matt,
glass bead blasted
Fixing
Length A results from:
Door leaf thickness + 11 mm + cylinder rosette
Supplied with
1 Single profile cylinder
3 Nickel plated steel keys
1 Fixing screw
Length A = external length of cylinder
Features
• Suitable for basic unit 3: Single profile cylinder
Supplied with
Fixing material
Finish Cat. No.
Plastic grey 911.52.292
Length A Length B Length C Cat. No.
27.5 mm 10 mm 37.5 mm 916.00.601 31.5 mm 41.5 mm 916.00.602 35.5 mm 45.5 mm 916.00.603 40.5 mm 50.5 mm 916.00.604 55.5 mm 65.5 mm 916.00.605 60.5 mm 70.5 mm 916.00.606 65.5 mm 75.5 mm 916.00.607
AH 2.60 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Features
• Suitable for basic unit 1: Panic lock
• For timber or steel doors
• For rebated or flush doors
• Suitable for application in escape and rescue routes
• Suitable for DIN left and right hand
• Suitable for door leaf height up to 2,650 mm
Supplied with
2 Latch parts and covers
2 Vertical rod type touchbars top and bottom
3 Bar guides
2 Striking plates
1 Set of fixing material
1 Set of installation instructions
Basic unit 4: Latch parts and vertical rod type touchbar
Finish
Covers Steel grey lacquered
Latch parts Steel yellow chromatized
Latch Stainless steel
Vertical rod type touchbars Steel grey lacquered
Bar guides Plastic grey
Cat. No. 911.52.302
AH 2.61New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Area of application: For rebated or flush, single or double wooden or
steel doors
Suitable for: Fire resistant and smoke control doors
Door width: 840 – 914 mm
Door thickness: 43.9 – 50.8 mm
Mounting: For DIN left and DIN right hand use
UL listed for ANSI A 1563
Function
Opening of door from inside: By pushing the touchbar
Opening of door from outside (optional): By activating the lever
handle. Key locks or unlocks lever handles (ANSI cipher bit function)
Inside:
- 1 Touchbar A
Outside:
- 1 Lever handles with round rosette E
Product components for single doors Product components for double doors
Panic exit device
Inside:
- 1 Touchbar with vertical locking rod B
Outside:
- 1 Lever handle on backplate D
Inside:
- Action leaf: 1 Touchbar A
- Inactive leaf: 1 Touchbar with vertical locking rod B
and 1 striking plate C
Outside:
- 1 Lever handle on backplate D or
- 1 Lever handles with round rosette E
Inside:
- Action and inactive leaf: Touchbar with vertical locking rod B each
Outside:
- 1 Lever handles with round rosette E
AH 2.62 New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
Packing: 1 pc.
Supplied with
1 Touchbar
1 Striking plate
B Touchbar with vertical locking rod
A Touchbar
Cat. No.
911.56.036
Cat. No.
911.56.037
Packing: 1 pc.
AH 2.63New products and systems: www.hafele.com
We
rese
rve
the
right
to a
lter
spec
ifica
tions
with
out n
otic
e.
Locking and SecurityPanic Exit Device
2
C Striking plate
E Lever handle with round rosette
Area of application
For double doors inside: Active leaf with touchbar A,
inactive leaf with touchbar with vertical locking rod B
Cat. No.
Striking plate 911.56.024
Cat. No.
Lever handle with round rosette 911.56.038
Packing: 1 pc.
Packing: 1 pc.
D Lever handle on backplate and cylinder
Cat. No.
Lever handle with round rosette 911.56.028