Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
EMCO ELECTRONICSEMCO ELECTRONICSWelcomes YouWelcomes You
CompanyCompanyEmco Electronics established in 1973 initially as an R&D outfit
progressively grew into a full fledged manufacturing and marketing organisation. It started off by manufacturing Test Measurement & Control devices & Instruments which activity has today become our companys CORE COMPETENCY. In fact, the CORE strength accumulated by the company over last so many years has enabled EMCO ELECTRONICS to enter into new lines of business like agency activity & establishment of PCBs Test & Repair Center.
Emco Electronics is an ISO 9001:2008 certified Company. The Factory is located at Vasai (Thane Dist.) with Head Office at Lower Parel (Mumbai).
A Branch office at Bangalore enhances sales & service support tothe Southern Region.
Present ActivitiesPresent Activities
Manufacturing
PCB Repairs
Marketing
ManufacturingManufacturingThe Company manufactures products for the Transformer Industry like
! Automatic Voltage Regulating Relays (AVRs) :for controlling voltage of power transformers
! Tap Position Indicators (TPIs) :for indicating the current Tap position of the Power Transformer
! Remote Oil/Winding Temperature Indicators (ROTI/RWTI) :for indicating Oil/Winding temperature of Transformer on Remote Panel
! Parallel Control Unit (PCU) :for controlling 2 Transformers in Parallel
! Voltage Controller Control Unit (VCCU) :for Servo Voltage Stabilizers
! Transmitters :for transmitting Tap No./OTI/WTI temperature in terms of 4-20 mA output
for remote SCADA display! Transformer Temperature Controller (TTC) :
for Dry type Transformers! Current Converter Unit with Repeater
PCB RepairsPCB Repairs
PCB Test & Repair Centre, located in the heart of Bombay City ( Lower Parel ) can today be claimed as one of India's best equipped and modern Hi-tech DIAGNOSTIC & REPAIR Centres of it's kind. The centre , well equipped in terms of qualified personnel & sophisticated ATEs (Automated Test Equipment) from world's best manufacturers is today ready to take any kind of challenge to repair the most complex PCBs.
We specialize in repairs of PCBs of Analytical Instruments, like Gas Chromatographs, Spectrophotometers, HPLCs, .. etc.
We are one of the regular vendors for repairing PCBs of Defense Equipments.
R&D CenterR&D Center
! R&D Center is recognized by the Dept. of Science & Technology of Govt. of India since 1974
! All the products manufactured at Emco Electronics are developed in-house and meet the Quality Standards as required by the Customers
Quality PolicyQuality Policy
Quality at EMCO ELECTRONICS means every individual needs to correctly understand Customer Requirements, both for Internal and External Customers, for ensuring Total Customer Satisfaction at an Optimum Cost, through Continual Improvement
ISO CertificateISO Certificate
EMCOELECTRONICS
an ISO 9001:2008
Certified Company
ProductsProducts
!EE301-M : Regular Model!EE301-T : Integrated Model with Built-in TPI!EE302 : Microcontroller based Model!EE303 : Microcontroller based Model with TPI!EE301-E : Economy Model
AUTOMATIC VOLTAGE REGULATING AUTOMATIC VOLTAGE REGULATING RELAYSRELAYS
Block Diagram of AVRBlock Diagram of AVR
AVR EE 301AVR EE 301--EE
! Digital Readout for PT Supply and Dead-Band Settings
! LED Indicators for Raise, Lower Pre-Signals and Undervoltage and Relay Operation Condition
! Continuously adjustable Time Delay Setting! Automatic Resetting after voltage correction! Single Pulse or Continuous pulse Operation of
Control Relays! Undervoltage Internal Blocking
EE-301E Wiring Diagram
7654321
987654321
Aux I/P PT I/P RCom
L UV
AVR EE 301AVR EE 301--MM! Modular Design! Separate Nominal Value and Bandwidth Settings! Continuously adjustable Time Delay setting! Undervoltage Alarm contacts with Internal Blocking! Test mode for testing AVR on Panel! Options :
Line Drop Compensation Normally Closed Auxiliary Supply fail Relay Contacts Normally Open Control Fail Relay Contacts User defined settings for PT. Supply, Time delay and Under
voltage Blocking. 4-20mA I/P for Remote Control of NVA
AVR EE 301AVR EE 301--TT! Separate Nominal Value and Bandwidth Settings! Continuously adjustable Time Delay setting! Undervoltage Alarm contacts with Internal Blocking! Built-in TPI for maximum 35 Taps, 1K step
resistance with optional 4-20mA O/P! Control Fail Relay (CFR) available as Standard feature! Overvoltage Blocking at 132V & Restoration at 127 V! Combined UV/OV Relay contacts for Blocking.! Test Mode for testing AVR on Panel options : LDR, AFR
EE-301M, EE-301T Wiring Diagram
Aux I/P PT I/P CT I/P AFR LR
16151413121110987654321
RR UV CFR
2120191817
Max 4-20mA O/P
(optional)
(only for EE-301T)
Com Min
AVR EEAVR EE--302302! Microcontroller based Architecture with Analog/Digital Converter! Keyboard entry for Parameter Settings! Linear or Inverse Time Response! Two independent timers for first and subsequent pulses! Single Pulse or Continuous Pulse Operation! Load Shedding at 3%, 6% and 9%! Readout of Prim. and Sec. Voltages in KV, Volts and % Deviation! Independent Lower and Raise settings in % of Nominal Value! High Speed return action for Overvoltage Condition
! Options Line Drop Compensation Normally closed Auxiliary Supply Fail Relay Contacts Built-in Tap Position Indicator upto maximum 35 taps with 1K step Res. Overcurrent Blocking @ 150 % of rated current with a pair of NO contacts
1413121110987654321
2827262524232221201918171615
Aux I/P
PT I/P
Aux FilO/P
LR
CT I/P
RR OV UV CFR AFR Max
LS3
LS6
LS9
Com
TPI com
Min
TPI
EE-302 Wiring Diagram
AVR EEAVR EE--303303! Microcontroller based Architecture with Analog/Digital Converter! Keyboard entry for Parameter Settings! Linear or Inverse Time Response! Two independent timers for first and subsequent pulses! Single Pulse or Continuous Pulse Operation! Readout of Prim. and Sec. Voltages in KV and Volts! Independent Lower and Raise settings in % of Nominal Value! Built-in Tap Position Indicator upto maximum 35 taps with 4-20mA O/P! In Manual mode, Taps can be Raised or Lowered via Keyboard! Test mode for testing of AVR operations for all conditions! Min PT, Max PT and Tap Change Count recording! Remote AVR Disable through Potential free contacts with Remote Indications! Overvoltage Blocking action as per the set value
! Options Normally closed Auxiliary Supply Fail Relay Contacts PT display of 433V instead of 110V
1413121110987654321
262524232221201918171615
Aux I/P
PT I/P
LR UV
OV 4-20 mA O/P
CFR AFR
Max
Com
com Min
EE-303 Wiring Diagram
RR A/M
TPI
DisI/P
TcpI/P
! EE601 : Standard Model! EE601-S : Small Model! EE601-G : TPI with Grey Code Input! EE604 : TPI with Counter! EE605 : TPI with Voltage Display! EE606 : TPI with Dual Polarity! EE607 : TPI with BCD Input! Optional 4-20mA I/p & O/p available
TAP POSITION INDICATORSTAP POSITION INDICATORS
TPI Block DiagramTPI Block Diagram
654321
0V 110V 230V Max Wip Min
4321
Dual 4 -20 mA O/P
+ - + -
TPI GENERAL Wiring Diagram
General Specifications of TPIGeneral Specifications of TPIModel EEModel EE--601601
! No. of Taps : 35! Step Resistance : 1K or User defined! Auxiliary Supply : 110/230 V AC ± 10%! Panel Cutout : 90 x 90 mm
: 90 x 48 mm for EE601-S! Options
4-20mA Output with 100E termination Resistance for SCADA 4-20mA Input instead of 3 wires resistance chain Suitable for 2 wire Resistor Chain Input Universal Auxiliary Supply from 95V to 260 V AC/DC
TPI ModelsTPI Models! EE-604 : Additional 6-digit display for Tap Change
Counter
! EE-605 : Additional 6-digit display for Tap Voltage
! EE-606 : Tap No. displayed with Positive or Negative polarity with respect to center position
! EE-607 : Tap No. displayed according to 6-digit BCD Input from encoder
! EE 601-G : Tap No. displayed according to 5- digit Gray code Input from encoder
EE-701 : TRANSMITTER for TPI and ROTI / RWTISuitable for TPI and ROTI/RWTI
Direct PT-100 Sensor Input available
Dual 4-20mA O/P
Din-Rail or Wall Mounting
Universal Power Supply – 95 to 260 V AC/DC
EE-602 : Remote Oil/Winding Temperature IndicatorInput Resistance of 0 to 440E / 2.8K/ User defined
Optional 4-20mA I/P or PT-100 Sensor Input available
Optional 4-20mA O/P available
Temperature range of 0oC – 150oC
Universal Power Supply – 95 to 260 V AC/DC\
ROTI / RWTI AND TRANSMITTERROTI / RWTI AND TRANSMITTER
EE-402 : VCCU for Servo Voltage StabilizersIndependent Settings for Lower, Raise, UV & OV
Variable Time delay Settings
LED Indications for Raise, Lower, & Time delay Operations
Projection Mounting
VOLTAGE CONTROLLER CONTROL UNITVOLTAGE CONTROLLER CONTROL UNIT
121110987654321
230V RR COM LR NO COM NC NO COM NC
OV UV
VCCU EE-402 Wiring Diagram
! Microcontroller based architecture with A/D Converter! Selectable Parallel & Independent modes of operation! Built-in Tap Position Indicators for both Transformers ! 4-20 mA output for both Tap Position Indicators! Selectable delay between master and follower pulses! Minimum/Maximum Tap Blocking! Out of step indication with contacts! Automatic control of parallel operation in Master Follower
mode even in absence of AVR.! Cost effective due to elimination of :
" Master Follower switches" Wiring from OLTC to Master Follower Switches" Single Panel Requirement" Integrated TPIs with 4-20 mA output for Scada
Parallel Control UnitParallel Control UnitEEEE--501501
! Monitors and Controls the Winding Temperature of 3 Phase Dry type Transformers
! Four Input Channels ! Auto Scan or Hold Mode of operation! Each Channel has programmable Threshold, Delay and Hysteresis! Potential free, 1 C/O relay contacts for Fan, Alarm, Trip and Fault
Conditions.! Max mode for viewing the maximum temperature reached by each
channel! Auto Calibration feature for calibrating the unit in field! 4-20 mA output for any one selected channel! Easy to operate user interface using front panel keys
Transformer Temperature ControllerTransformer Temperature ControllerEEEE--801801
Current Converter Unit
! Integrated Oil and Winding Temperature Indicator in Single Unit! Monitors and Converts Oil and Winding Temperatures in terms of
4-20mA DC Current! PT-100 Sensor Input for Oil Temperature and 0-5 Amp Current Input for
Winding Temperature Indications! 3-Digit 7-Segment LED Displays for OTI and WTI each! Dual 4-20mA DC Current Output for OTI and WTI each
Repeater! Remote Oil and Winding Temperature indicators in Single Unit! 4-20mA Input for ROTI and RWTI each! CCU and Repeater as a complete set.
Current Converter Unit with RepeaterCurrent Converter Unit with RepeaterEEEE--608 with EE608 with EE--609609
! Din-Rail Mounting
! Maximum upto 35 Taps (or as specified)
! 1 KΩ Step Resistance (or as specified)
! Automatic Detection of Maximum Tap No.
! Automatic Adjustment of 4-20 mA Output
! Dual 4-20 mA Output available for Remote Indicators and SCADA
! Universal Power Supply (95 260 V AC/DC)
! TPI with 4-20 mA Input Feature available (Optional)
TAP Position IndicatorTAP Position IndicatorEE 601EE 601--WW
Export OrdersExport OrdersEmco Electronics products are Exported to International Countries like
UAE, Oman, Singapore, Brazil, Columbia, Bhutan, Nepal, Australia
AustraliaDelixi Australia Pty Ltd.Dubai, UAEGulf Radiant Electrical & Trading LLC.BrazilToshiba Do Brazil S.AQatar, ColumbiaSeimens Ltd.Sultanate of OmanOman National Electric Co. (S.A.O.G)NepalNandan Ghee & Oil IndustriesU.A.E.Emirates Transformer & SwitchgearsSultanate of OmanDhofar Power Company S.A.O.G.MalaysiaDOM Industries (M) SDN. BHD DhakaDhaka Electricity Supply AuthorityBhutanBhutan Carbide & Chemicals LtdSingaporeAreva T&D Pte. Ltd
Our Our Esteemed Esteemed CustomersCustomers
All major
! Transformer manufacturers! Panel manufacturers! Electricity Boards! Private Power Suppliers
Quality Control & AssuranceQuality Control & AssuranceWe at EMCO have been making our very best efforts to establish a
high standard of Quality and Reliability of our products as may be seen from the various measures adopted by us over a period of time for realizing our goal.
! Commitment to accuracy , Reliability, Performance and Services ! Striving towards achieving ZERO DEFECTS / ZERO
REJECTIONS in the manufacturing process! Raw materials and Accessories of Best Quality! Strict Quality Control at every stage! Excellent workmanship! Rigorous Tests to exacting standards! Latest manufacturing techniques and processes! Continuous development for improving products! Prompt after Sales Service
Customer ServiceCustomer Service
! Free replacement of unit within Warranty period! Minimal repair cost after Warranty period! Dispatch of repaired unit within 3 days of receipt! Immediate On-Site service when required! Service support on Phone/Email/Fax
EMCOEMCO
representsrepresents
BharaniBharani ElectronicsElectronics
Annunciators Buzzers AMF Controllers
Power Packs
for
AnnunciatorsAnnunciators ....! Manufacturer of Quality Products since 1965! Installation for prestigious clients which include PGCIL, NTPC, NPCIL,
EIL, NHPC, and all Electricity Boards! Areva, Chennai – Pallavaram unit is using Bharani Annunciators in
large quantities for last 15 years! Products exported to Saudi Arabia, Srilanka Indonesia, Bangladesh etc.! Unconditional Life Time Guarantee for manufactured products! Most Advanced Micro Controller Single Chip Embedded System! Status Indicators + Watch Dog provided! All sequences of operation as per ISA! In-built push button switches for annunciator functions! Automatic Switching of window colors! Snap fit window frames in 7 different sizes! Universal Operating Voltage! Serial Communication interface (optional)! DC or AC Supply Fail Annunciation (optional)
AMF ControllerAMF Controller! Rugged Flush-mounted Unit with Micro Controller Technology! Wide range of Auxiliary Supply : Unit operates between 06 VDC to 35
VDC ~ continuously variable! Withstands Cranking-Dropout dip upto 0 VDC of Auxiliary Supply upto
01 second [maximum]! Continuous supervision of Mains [EB] & DG Breaker status, thus ensuring
human & equipment safety! Internal interlock for Mains & DG Breaker, with LED Indication of
respective CB status, for fails safe operation! Facility to select : 12V or 24V Battery, with indication & supervision of
selected Battery Voltage status! Two spare Terminals for connecting external (Aux. Input) Faults! LED Fault Annunciation for : Start Fail, LLOP, High Engine Temp.,
Engine Fault, Low Battery, Aux. Faults 1 & 2! Front Panel Keypad Switches provided for : Auto, Accept, Manual
ON/OFF & Emergency STOP! Unit has two major modes of Operation ~ viz : Configuration Mode and
Run Mode
Power PacksPower Packs! Adequate DC energy for energizing trip &
close coils of Breakers! Built-in Capacitors to store energy on failure of AC Supply! Trip supply healthy indication by LED (Optional)! Can be used as Capacitor Trip Device in unmanned substation
BuzzerBuzzer! Sounds upto 4 different Tones simultaneously (Spaced Out/
One-after-Other) when all alarms in a Panel occur simultaneously! Hence, one buzzer sufficient to sound all audible alarms in a panel! User saves cost and need for multiple buzzers! True Multi-Tone and All-in-One Buzzer! Available in One tone unit to Four tone unit
! Universal Operating Voltage between 30V to 300V! Hi-Volume dB Output compared to conventional Buzzers
Thank You