Behavior Detection System
VibraImage
Manual
Version 10.2.0.223
ELSYS Corp.
WWW.ELSYS.RU
WWW.PSYMAKER.COM
Saint-Petersburg
2020
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
2
Content
Introduction ................................................................................................................. 5
1 Useful information .................................................................................................... 8
1.1 Basic applications ...................................................................................................................... 8
1.2 System specifications ................................................................................................................ 8 1.2.1 VibraImage system parameters ............................................................................................ 8 1.2.2 Digital (web) camera requirements ...................................................................................... 8 1.2.3 System requirements............................................................................................................. 9
1.3 Package content ....................................................................................................................... 10
1.4 Software specification ............................................................................................................. 10
2. Before you begin .................................................................................................... 11
2.1 Operating limits ...................................................................................................................... 11
2.2 Software installation ............................................................................................................... 14 2.2.1 Digital camera driver installation (*).................................................................................. 14 2.2.2 Guardant dongles driver installation ................................................................................... 14
2.2.3 VibraImage installation ...................................................................................................... 15
2.3 First start of VibraImage system ........................................................................................... 16 2.3.1 Video quality auto checking function ................................................................................. 17 2.3.2 Video setting ....................................................................................................................... 20
2.3.2.1 One camera ................................................................................................................................ 20 2.3.2.2 Multi cameras mode (Overview) ............................................................................................... 21 2.3.2.3 Saved video ............................................................................................................................... 23
3 VibraImage. Users manual. Basic function. ........................................................ 24
3.1 Multifunction window ............................................................................................................ 24 3.1.1 Basic window design .......................................................................................................... 25 3.1.2 Windows position control ................................................................................................... 29
3.2 Main menu ............................................................................................................................... 31 3.2.1 Menu «File» ........................................................................................................................ 31
3.2.2 Menu "View" ...................................................................................................................... 32 3.2.3 Menu "Settings" .................................................................................................................. 34 3.2.4 Menu «Action» ................................................................................................................... 37
3.2.5 Menu "Help" ....................................................................................................................... 38
3.3 Image area control .................................................................................................................. 39 3.3.1 Choice of the main display mode ....................................................................................... 39 3.3.2 Submenu "Mode" ............................................................................................................... 42 3.3.3 Graph display ...................................................................................................................... 46 3.3.4 Graph analyze ..................................................................................................................... 48
3.4 Toolbar ..................................................................................................................................... 50
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
3
3.5 Vibraimage parameters .......................................................................................................... 51 3.5.1 Т1-Т12 parameters ............................................................................................................. 54
3.6 Information panel ................................................................................................................... 55 3.6.1 Information panel. VI mode. .............................................................................................. 56 3.6.2 Information panel. M mode. ............................................................................................... 58 3.6.3 Information panel. LD mode. ............................................................................................. 60 3.6.4 Information panel. GR mode. ............................................................................................. 61
3.6.5 Information panel. С mode. ................................................................................................ 64 3.6.6 Information panel. S mode. ................................................................................................ 66 3.6.7 Information panel. DB mode. ............................................................................................. 75
3.7 Save of measurements results ................................................................................................ 76 3.7.1 Save of current images ....................................................................................................... 76 3.7.2 Save of video file ................................................................................................................ 77 3.7.3 Save of results and settings files ......................................................................................... 78
3.7.4 Auto capture image in Macro mode ................................................................................... 79
4 The basic modes of the VibraImage system ......................................................... 81
4.1 Micro mode. Emotions (personality traits) definition ......................................................... 82 4.1.1 "M" mode of information panel .......................................................................................... 90
4.1.2 Psychophysiological state analysis results ......................................................................... 92
4.2 Macro mode. The suspicious people detection in crowd ..................................................... 97 4.2.1 "Macro" mode parameters .................................................................................................. 97
4.2.2 Face detection mode ......................................................................................................... 102
4.2.3 First start and settings selection for Macro mode ............................................................. 105
4.3 Mix mode. The suspicious people detection with high accuracy ...................................... 107 4.3.1 Mix mode parameters ....................................................................................................... 107
4.3.2 First start and settings selection for Mix mode ................................................................. 110
4.4 LD mode. Lie detection ......................................................................................................... 112 4.4.1 Before starting LD mode .................................................................................................. 112 4.4.2 Switch on LD mode .......................................................................................................... 113
4.4.3 LD working mode ............................................................................................................. 115 4.4.4 Additional settings in "S" information panel .................................................................... 117 4.4.5 Settings in «LD"information panel. .................................................................................. 119
4.4.6 Backster’s test ................................................................................................................... 122 4.4.7 Lie detector with questionnaires ....................................................................................... 123 4.4.8 Questionnaires stucture ..................................................................................................... 127 4.4.9 Create new questionnaires ................................................................................................ 128
4.4.10 Psychophysiological detection of deception in semi-automatic mode without
questionnaires ............................................................................................................................ 129 4.4.11 Psychophysiological detection of deception in semi-automatic mode, random questions
................................................................................................................................................... 130 4.4.12 Recording the main test LD results ................................................................................ 130
4.4.12.1 Graphics of psychophysiological state changes .................................................................... 132 4.4.12.2 Recording the main test results .............................................................................................. 135
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
4
4.4.13 Ranking mode of reactions to questions ......................................................................... 139 4.4.14 Video recording during testing and mark standing ........................................................ 141
5 Operation with external devices ......................................................................... 142
5.1 Operation with EEG devices ................................................................................................ 142
5.2 Operation with a fingerprint scanner and registration of the pulse wave. ...................... 144
6 Vibraimage. General info .................................................................................... 146
7 Warranty ............................................................................................................... 148
7.1 Disclaimer of Warranties ..................................................................................................... 148
7.2 Limitation of Liability .......................................................................................................... 149
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
5
Introduction
Welcome to the VibraImage World! Thank you for your purchase of VibraImage
system. This Manual is written to help you enjoy vibraimaging and open new features in well-
known objects!
VibraImage technology measures micromovement (micro motion, vibration) of person by
standard digital, web or television cameras and image processing. Human head microvibration is
linked with the vestibulo-emotional reflex (VER) of a person and reflects emotion status and
personality traits. VibraImage system detects human emotions by the control of three dimensional
(3D) head-neck movements and fluctuations, accumulated as frame difference in several video
frames.
Fig.1. Frequency vibraimage of the person Fig.2. External vibraimage around the frequency
vibraimage
VibraImage is a new image type and so primary, as original color image, thermo image or x-
ray image. Each image type gives new and unique information about the object. Every pixel of
vibraimage reflects vibration parameters - frequency or amplitude (fig. 1) of vibration. One frame
visualization of vibration frequency and amplitude named external vibraimage and looks like aura
(vibra-aura) of person (fig. 2). Typically, external vibraimage colors linked with vibration frequency
and external vibraimage dimension linked with vibration amplitude.
The method, system and the device of said VibraImage technology are protected by
the patents of Russian Federation RU 2187904 (fig.3), RU2289310 (fig. 4), RU 2510238 (fig. 5), RU
2515149 (fig. 6), RU 2629247 (fig. 7), RU 2695888 (fig. 8), Software Registration N2006614137
(fig. 9), United States Patent US 7346227, Korean patent KR 10-1500888 and awarded with Gold
medal on the international exhibition of inventions and innovations Brussels - Eureka 2002 (fig. 10)
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
6
Fig.3. Patent of Russian Federation
RU 2187904
Fig.4. Patent of Russian Federation
RU 2289310
Fig.5. Patent of Russian Federation
RU 2510238
Fig.6. Patent of Russian Federation
RU 2515149
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
7
Fig.7. Patent of Russian Federation
RU 2629247
Fig.8. Patent of Russian Federation
RU 2695888
Fig.9. Diploma of international exhibition of
inventions and innovations Brussels - Eureka
2002
Fig.10. Certificate on official registrations
Software VibraImage in Russian software
database
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
8
1 Useful information
1.1 Basic applications
Human emotions control system (further - VibraImage) intends for registration, analysis,
control and research of human emotion, functional and psychophysiological states for different
applications in the fields of security, biometrics, psychology, medicine, electronics and human life.
VibraImage software solves the following targets:
Psychophysiological parameters monitoring and detection;
Emotion recognition;
Lie detection;
Monitoring of person physiological parameters;
Video surveillance in real time by vibraimage and suspicios person detection;
Psychological testing and interview
1.2 System specifications
1.2.1 VibraImage system parameters
Resolution, TVL, not less 400
Noise level of VibraImage, bit, less than 0,1
Frame rate, f/s, not less 25
Frequency range, Hz, more than 0,1 10
1.2.2 Digital (web) camera requirements
Sensor CMOS/CCD
Resolution, pixel, not less 640 х 480
USB compatible USB 1.0; USB 2.0, USB 3.0, IP
Frame speed, f/s, not less 25
Microphone external (not built-in camera)
Exposition control auto and manual
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
9
Color mode color and B/W switch
Flicker mode Flicker 50 Hz and 60 Hz
1.2.3 System requirements
Operation System Microsoft Windows better then Windows 7,
only 64-bit version!!!
Processor PC with Pentium Core Duo2 2400 or better
RAM 8 Gb or more
HDD Recommended SSD type more than 500 Gb
USB port 2 free USB ports version USB 2.0
Software DirectX 9.0 or later
Video capture WDM-compatible video device
Audio audio capture device (support 16-bit data and
44100 Hz stream frequency)
Network LAN 100Mb/s or better
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
10
1.3 Package content
1. VibraImage PRO and Guardant dongle - 1
2. User’s Guide (Manual) - 1
3. Digital USB camera (option) - 1
4. Disk or flash card with vibraimage info (option) - 1
5. Personal computer (option) - 1
1.4 Software specification
Video source
In directory \Soft\VideoCam utilities to test the functionality of a digital camera (provided it
supplies with a complex) are located. Detailed installation instructions of drivers of a digital video
camera are located on a CD disk (or other source) of the camera software delivered together with
the camera.
VibraImage
In directory \Soft\ the installation package of the VibraImage10.exe program is located. For
start of the program it is necessary to study recommendations about the installation, specified in
the section "VibraImage Program Installation" (see below). Also, the installation kit can be
downloaded from the website http://www.psymaker.com/downloads/Vibraimage10.exe.
Guardant drivers
Before starting VibraImage 10.x, you must install a device driver hardware lock (dongle). In
the catalog \Soft\ Guardant2eng the installation package dongle drivers are located. To run
the program should be read the recommendations for installation specified in the «Guardant dongles
driver installation" (see below).
Note, to install the driver in W7/W8/W10 administrator rights are required!
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
11
2. Before you begin
2.1 Operating limits
Power supplies requirements for hardware
1. Power supply must be 220 V in 50 Hz via an uninterruptible power supply (UPS) with
feedback. UPS capacity should be sufficient for the functioning of the system for at least 20
minutes needed to save the results of analyzing and processing.
2. For low noise and reliable system action the monitor, power units of cameras should be
connected to an electric network through the special sockets having additional ground contact
(the socket of a class 1).
3. For reliable maintenance system the equipment included in complex and the equipment,
taking place in direct near should be certificated on electromagnetic compatibility according
to requirements.
Light exposure requirements
1. Natural illumination of object can be used only if speed of natural light exposure changes of
object does not exceed 1 Lx/s.
2. Illumination of object by fluorescent lamps with illumination in a range 400 - 600 Lx in a
plane of object is preferable.
3. When the system operated in continuous mode the lighting in indoor all time should be from
400 to 600 lux.
Camera vibration requirements
1. The television camera used for surveillance and-or object on which the camera is established,
should be motionless.
2. Allowable vibration speed of television camera not more than 0.1 mm/sec in the range (0.1 –
50) Hz.
Settings VibraImage recommendations
For correct results, you must minimize:
Light sources, fixtures and bright surfaces, windows, etc.
Window, which gets the image from the streets.
Glass surfaces such as walls, which change with the lighting system in the room or on the
street lighting can act as "mirrors"
Light sources with variable lighting (flickering, flashing, etc.) or lighting systems, which
are moved mechanically (subject to vibrations from external factors).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
12
Light sources with a unidirectional light, i.e, a person must uniform illuminated from all
sides,
Outside people influence,
The moving objects, sliding doors, people passing by, etc.
Hardware Requirements
1. The resolution of the TV camera should be at least 640 x 480 pixels, and the rate of input
video frames to a computer for at least 25 – 30 frames / sec.
2. It is recommended to use the TV cameras with low noise.
3. After starting the program VibraImage CPU load should not exceed 80 %.
4. The computer's hardware must provide performance sufficient to be processed in real time at
least 25 frame/s received from the television camera.
Factors affecting the quality of vibraimage
The following factors are taken into account it is recommended to get the correct vibraimage
person:
1. An object (person) has to be well and evenly lit, and normal (black and white or color) image
of a man should be clear and contrasting. human face in the frame should be no smaller than
200 pixels.
2. The person must be in its natural state, when its movements are determined by unconscious
processes, especially the vestibular system. It is necessary to exclude the presence of
additional mechanical contact sources (for example, a man leaned against a certain subject,
leaned on the table, leaned his head by hand).
3. Vibraimage Micro mode is designed for the visualization of vibration only one object in the
frame, so the live objects that are close to the main object of study, can significantly affect
and distort the vibraimage of the main subject.
4. There is a certain delay between the current psychophysiological state and vibraimage. The
value of this delay is mainly determined by the selected accumulation time. For example,
when the real system performance 25 f / s and the selected time N = 100 frame, the objective
vibration aura of a person can be displayed on the screen is not earlier than 4 seconds after the
person in front of the camera. Therefore, a person must remain in the camera frame for at least
10 seconds based on Nyquist–Shannon-Kotelnikov theorem.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
13
Note
The correct analysis of person emotion levels and lie detection is possible only at detail
execution of the recommendations stated in the given document, and by processing of high
quality vibraimage.
It is recommended to system users to be trained and certification of the user on special
courses and to use of VibraImage, certificated by ELSYS corp.
User of VibraImage system should use the system for research and monitoring of the
psychophysiological state in accordance with the common law and in accordance with the
legislation of the country in which the system is used without violating the rights of the
investigated person.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
14
2.2 Software installation
2.2.1 Digital camera driver installation (*)
(*) – Available on request
If the user uses own USB camera, it is need to install drivers for video capture device like web
cam according to it manual.
Note, restart the system after camera driver installation.
2.2.2 Guardant dongles driver installation
Note, for driver installation in NT/2000/XP/W7/W8/W10 the administrator rights are
required!
Perform the following steps to install the dongle Guardant driver for NT/2000/XP.
1. Close all other applications to avoid file sharing errors;
2. Run INSTDRV.EXE application from "Guardant drivers" folder "\Soft\Guardant2eng\";
3. When the utility is started, it will check the presence of Guardant driver in the system. If
the driver is not found, only [Install driver] button will be available in the main window. To
install or update Guardant driver click on [Install driver] or [Reinstall driver] button. If
installation is completed successfully, INSTDRV will display a corresponding message and
then return to the main window.
4. If the driver installation is successful, a message box is displayed.
5. Click [OK] to continue.
6. Close INSTDRV application.;
7. Restart the system.
8. Connect video capture device and dongle to PC.
9. Run VibraImage.exe
Note
By default, the system installs the driver for 64-bit Windows 7. If necessary, you can manually
install the required driver of folders "\Soft\32\" or "\Soft\64\".
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
15
2.2.3 VibraImage installation
It is necessary to execute the following actions for installation of VibraImage program on your
computer:
1. Run setupVibraPro10.exe file
2. Choose language of installation in appeared window;
3. Press button "Next" in the appeared window;
4. Accept the license agreement and to press button «Next"in the appeared window;
5. In the appeared window specify a way to the catalogue where files of the program will be
written down, then to press button "Next";
7. The next two screens allow the creation of a shortcut in the Windows menu “Start” and
VibraImageEx icons on your desktop computer
8. Press button "Next" in the appeared window, allows installation of software files on your
computer;
9. Press button "Close" at the end of installation.
10. VibraImage program pictograms appears after the end of installation in system menu and
on desktop of your computer
11. Connect dongle to USB port of computer and start. VibraImageEx.exe.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
16
2.3 First start of VibraImage system
1. After the first start of the program you will see the progress bar (fig.2.1) that means loading
process bar.
Fig. 2.1 Progress bar
2. First program window shown in fig. 2.2
Fig. 2.2. First program start
3. In menu "Settings" => "Language" select interface language (Fig. 2.3).
Fig. 2.3. Select language
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
17
4. Once connected to the computer camera in the menu "Settings" => "Video" (Fig 2.4) you
need to select the camera to work (in Fig 2.4 – Microsoft Lifecam Cinema camera).
Fig. 2.4. Video camera connecting
5. After correct connecting the camera the image appears on the screen.
6. Perform video camera settings (see. ch. 2.3.2).
7. Perform quality control of videoimage (see. ch. 2.3.1) and, if it necessary, eliminate the causes
of low-quality video.
8. Select the directories for recording video information and log files (see. ch. 3.6).
9. Get started in accordance with the program description.
2.3.1 Video quality auto checking function
The VibraImage program has built-in automatic quality control function image quality control
during the test. Since the calculation of human reaction using the video image, the quality control for
the processed video is necessary to obtain a correct test result. Error message and the low quality of
video will appear on top of the QT windows (Fig. 2.5), but only if the "Quality test" mode in "S"
information panel is switch on.
Program gives error indication if the image quality is lower than standard vibraimage requests:
Error 1 – indicates when facial image is lower than necessary. For cancel this error is need to
move checked person near to camera or start zoom function on camera.
Error 2 – indicates when camera noise level is higher than necessary. The reason of this error
could be low illumination, incorrect camera settings or camera vibration.
Error 3 – indicates when computer input frame rate is lower than necessary. Requested norm
for processed frame rate is more than 24 f/s. This errors indication was done for deleting unqualified
staff influence during results control.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
18
Fig. 2.5. Error message 1 – low quality of image
The size of the person's head image in the picture elements (pixels), which determines the
accuracy of recorded vibrations, requires constant monitoring during testing. When tested with a
video image analysis there are no severe restrictions on the movement of the test person, as required
by the contact method. This person feels natural, which increases the accuracy of test results.
However, the natural behavior can lead to the fact that during the test response deviates
from the camera and the size of the human head image becomes less than required. To resolve this
issue vibraimage system constantly monitors a person's head size of the image and displays an error
message (1) in the window "QT" in the case of reducing the size below the limit. In addition,
vibraimage program includes a permanent face detection algorithm, which ensures elimination of
errors from a lack of a real image of the person in the frame during testing.
Temporary noise signal from the video camera includes a video camera noise and
illumination instability and can significantly affect the test results. In this case, at the slightest noise
level exceeds the specified threshold, the system automatically displays an error message (2) in "QT"
window (see. Fig. 2.6).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
19
Fig. 2.6. Error message 2 – low illumination
Despite the fact that the television camera may transmit to 30 frame/sec with the set
resolution, it does not guarantee that the computer receives and processes the incoming video data in
real time. And any deviation from the information processing in real time resulting in a loss of
information and hence reduce the reliability of the test. By reducing the actual input frames
frequencies and processing frequencies below the set limit, the system automatically displays a
warning error (3).
Window "Quality Test" (QT) indicates the time in %, for which the image quality of
100 %. When the quality test indicates 43 % means that only 43 % of the testing time have no errors,
and the 57 % of test time the image quality contained 1, 2 or 3 errors.
Note, before the start of the test should ensure that the program processed the image of a
human without errors.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
20
2.3.2 Video setting
2.3.2.1 One camera
It is necessary to select in the main menu "Settings" => "Video" => ".../name used
camera/...". In figure 2.7 the process of selecting camera "Microsoft LifeCam Cinema" is shown.
If the camera is connected, selected and operated, then on the left of the name there will be an icon
"" (fig. 2.7), and the menu will be extended with the "Video capture filter" and "Video capture
format".
Select "Video capture filter..." in the submenu "Video" (fig. 2.8) for open menu of the
camera settings. Item "Video capture filter" appears in the menu only in case of the correct
installation of camera drivers and correct choice of operating camera.
Fig. 2.7. Select camera «Microsoft LifeCam Cinema»
After a choice of the "Video capture filter..." the window "Settings" will open. Settings
window differs depends on camera type. When adjusting the camera settings, you must fulfill the
following general requirements:
The "Brightness", "Contrast" and others parameters should be configured so that
the image of the object was the maximum contrast
Switch on "Flicker" mode for setting lighting power line frequency (repayment
flicker), in most countries it is 50 Hz.
If your camera supports, then switch on the black-and- white image "B / W mode".
If the camera works only in color mode, it is recommended to set "Saturation"
parameter to minimum value.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
21
Depending on the experimental conditions and light to use automatic or manual setting
"Exposure" parameter. If constant lighting, it is recommended to use the manual
adjustment. If changes (for example, an object depends on the lighting street lighting),
it is better to use the automatic adjustment mode setting.
Parameters "Zoom" and "Focus" is recommended to use in the manual mode and
change their values not due to electronic image processing, but by approaching /
removing the camera from the object.
Fig. 2.8. Opening "Video Capture Format" window
To open the video recording settings window must be select "Video Capture format..." in
the submenu "Video" (Fig. 2.8). The frame rate is necessary to set 30 as the frame size ("output size")
of not less than 640 x 480 elements. When using larger frames size in the program need to constantly
monitor the speed of the frame to the computer and the processing speed of your computer
(see. ch. 3.6)
Note, use free program CamIP for the IP network camera connection
(http://www.psymaker.com/downloads/CamIP64.exe). Parameter setting procedure is described in
the CamIp manual http://www.psymaker.com/downloads/CamIP_eng.pdf
2.3.2.2 Multi cameras mode (Overview)
In professional version, there is option to use simultaneously from 1 to 10 cameras.
Limitations for it are power of hardware (CPU load should not exceed 80 %) and settings of used
Guardant dongle.
If you want to use more than one camera for vibraimage processing, you need to set the
number of cameras in the "Information panel" => "Mode S" => "Main menu" => "Cores" (fig. 2.9).
For example, for 2 cameras you will see 2 windows. You need to choose (fig. 2.10) and set new
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
22
camera for each new window as it is described in 2.3.2.1. The more cameras you will choose, the
longer reboot of VibraImage program will be, for example, for 10 cameras it can be more than 1 min.
Fig. 2.9. Opening two cameras.
Fig. 2.10. Select camera «Microsoft LifeCam Studio" for 2nd image window
When you switch on several cameras in menu "View" item "Overview" appears (fig. 2.11).
Fig. 2.11. Item "Overview" menu "View"
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
23
By using item "Overview" user can open several cameras in addition window (fig.2.12). Also
in this window there is information about suspect level of the most dangerous person from each video.
Parameters of displaed video you can set when you open video as it is shown on the fig. 2.10.
Fig.2.12. Window "Overview" with 2 cameras.
2.3.2.3 Saved video
You can upload your video file in format AVI using menu "File" => "Open" or with
combination of buttons on your keyboard "Ctrl + O" or button on toolbar. To operate with
video, you should use items from submenu "Video" menu "Settings" (see ch. 3.2.3). To choose video
time there is toolbar "Video" (fig. 2.13) with slider for choosing time and button to stop video (on the
right side of the bar) that shows exact time from the start of the video.
Fig. 2.13. Toolbar "Video" with slider
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
24
3 VibraImage. Users manual. Basic function.
VibraImage software gathers, records, processes and analyzes electronic images of humans,
biological and mechanical moving objects with various frequency and amplitude of vibration
(fluctuations).
After starting the VibraImage program video images from camera or video file are displayed
in multifunction (basic) window.
3.1 Multifunction window
In heading of the basic window the following information is indicated (see Fig. 3.1):
type of video source: Video camera or AVI file;
model of video source: Video camera model or AVI file name;
name of running VibraImage module;
name of the current database record to which there is an operation.
Fig. 3.1. Multifunction window of VibraImage with style Windows XP
The program for the user’s convenience have the ability to change the style of the main
elements of the working window. To change the style, use the submenu "View" – "Application
styles" (Figure 3.2.).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
25
Fig. 3.2. Style Office 2003
3.1.1 Basic window design
In total in the main window of the program in addition to the video area, you can see an
additional 16 windows that display information about the parameters of mental and emotional state
of a person, and program settings (on Figure 3.3 the windows labeled corresponding numbers):
1. Toolbar – main toolbar.
2. Toolbar VI – toolbar for different vibraimages mode.
3. VI, M, LD, C, GR, S, DB – information panel windows.
4. Histogram – window for vibraimages parameters histogram in real time mode.
5. LD Question – questionnaire window for lie detector mode.
6. Suspect – human suspect level window
7. Graph – window for parameters graph.
8. QT – image quality window.
9. Image capture – window for "danger" person photo.
10. LDr – lie level window.
11. Video – slider for time management of video only if videosource AVI file.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
26
Fig. 3.3. Example of all type windows
The user can add or remove the window on the screen using the submenu "View" – "Toolbar"
(Fig 3.4.). But for different modes of program operation uses a different set of windows and the
simultaneous presence of all the windows on the screen is redundant.
When select one of the basic operation modes (micro, macro, mix or lie detection) and load
its default settings, the system automatically displays only the necessary for that mode window
(Fig. 3.5 – 3.7). Loading of the basic modes setting is performed using the sub menu "Settings" –
"Preset".
2 1 3 4 10 6 7 9 8 1 11
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
27
Fig. 3.4. Submenu for windows control
Fig. 3.5. "Micro" mode set
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
28
Fig. 3.6. "Macro" mode set
Fig. 3.7. "Lie detector" mode set
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
29
3.1.2 Windows position control
The user can control the placement of additional windows on the screen and the size using the
controls elements on the left side of each window title. For each window it is available control menu
(Fig. 3.8). This menu also appears when you click the left mouse button in finding the mouse pointer
in the desired window. In "Docking" mode, window position and size are fixed, and when
opening/closing the window will open in a given position. The mode "Floating" window position and
size can be changed by the user.
If the window is in a random location on the screen, then double-click the left mouse button
on the window, the window will move on the screen in the "default" position.
Fig. 3.8. Window control element
Each window can be closed, or by using the window menu or by using a separate control
element (Fig. 3.9).
Fig. 3.9. Control element "«close window"
Each window can be temporarily minimized and moved to the border of the main program
window (Fig. 3.10). Figure 3.11 additional windows hided and moved to the border of the main
window and they icons are highlighted in orange color.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
30
Fig. 3.10. Control element "hide window"
Fig. 3.11. All additional windows are hide.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
31
3.2 Main menu
The main menu contains the following items:
"File"
"View"
"Settings"
"Action"
"Help"
3.2.1 Menu «File»
Menu "File" contains following items:
Fig. 3.12. Menu "File"
Item "Open…" – it is intended for loading video or new face detection algorithms.
Item "Save settings as …" – it is intended for saving of the current system settings to
the external file.
Item "Load settings …" – it is intended for loading saved system settings from an external
file.
Item "LD Load text… " – it is use in LD mode for loading new LD questionnaire from an
external file.
Item "AVI: Start Capture" – start record AVI-file. If the database folder is not specified,
record of AVI files is blocked.
Item "Image capture …" – it is intended for saving current frame from area of images in a
folder of archive as BMP a file.
Item «Exit"- exit from program.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
32
3.2.2 Menu "View"
Menu "View" (fig. 3.13) defines visible in the basic window information and contains
the following items.
Fig. 3.13. Menu "View"
Item "Toolbar" – switch on/off the toolbars and additional functional windows.
Fig. 3.14. Menu "View", submenu for windows selected
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
33
Item "Application Look" is applied to change style of working window and its components
(Fig. 3.15).
Fig. 3.15. Menu "View", submenu for windows style
Submenu "Mode" defines additional configuration and number of windows with an image
displayed in the image area. Images also can be selected using the corresponding buttons on
the toolbar "Toolbar VI" (on fig. 3.6 at left side).
Fig. 3.16. Windows that appear to the image area.
Submenu "Preset" defines the type of the display image: the real image (mode LD),
vibraimage (mode VI), the aura on the real image (mode AR), the aura on vibraimage (mode AV).
Also, you can configure the corresponding buttons on the Toolbar (fig. 3.7).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
34
Fig. 3.17. Buttons and menu items defining type of displayed image
3.2.3 Menu "Settings"
Menu "Settings" (fig. 3.18) contains the following items:
The submenu "Language" contains the list of supported languages (see Fig. 2.2).
Fig. 3.18. Menu "Settings". Submenu "Defaults"
Submenu "Defaults" [Preset] is intended for set of system in one of an operating conditions
mode (micro, macro, mix or ld) with set parameters to default value (see fig. 3.5 – 3.7). Files of
default settings of the basic modes are stored in the catalogue \VibraImage10\defaults\
Fig. 3.19. Menu «Settings». Submenu «Video»
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
35
Submenu "Video" contains options of video modes. Its can differ depending on connected
devices. For example this menu contains the following items (fig. 3.19). You can choose as video
source one from many installing in PC video-devices or load external video file.
Note, for connection to system of network IP cameras (for example, in figure 3.19 CamIP
RTSP Example) and adjustments of their parameters the additional software CamIP.exe
http://www.psymaker.com/downloads/CamIP_installer.msi is used.
Subitem "Video Capture Filter…" – opens the window of video device setting (contrast,
exposition, and brightness). Each device has the especial window of settings.
Subitem "Video Capture Format…" – change video capture format.
The subitem «RGB8 compressor"is intended for management of a video file record format.
If this item is chosen, that, for economy of a space on a hard disk, the video file saved in a black-and-
white format.
The subitem "Disconnect" allows disconnecting all video camera or video file.
Subitems "AVI File…" and "AVI File (no sound)…" select for the analysis of an external
video file. The file can be loaded with a sound and without sound. The operation mode without sound
is used for VibraSound creation.
Subitems "Rotate CW" and "Rotate CCW" allow making turn of an input video image on
90 and 270 degrees before its processing in the VibraImagePro.
Subitems "Mirror X" and "Mirror Y" allow to reflect video file on axis X or Y
correspondingly.
Subitem "Save Settings" allows to save your camera settings if the video conditions don’t
change otherwise program settings will set by default at each new turn on the camera.
Submenu "Video mask"(fig. 3.14) allows to edit video data. If there is an additional mobile
object in the field of supervision it makes it difficult to measure the basic object. In "Edit mode",
you can cover "black" mask on addition object image. Also you can reset current mask ("Reset Video
mask" mode), save mask in external picture file in BMP format ("Export Video mask" mode) and
load external mask ("Load Video mask" mode).
Note, DON’T FORGET turn off "Edit mode" after masking. Otherwise, any click of
the mouse in the image will continue masking!
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
36
Fig. 3.14 Mask mode using
The item "Mitsar EEG" (in development) can be used in case of connection of the Mitsar-
EEG electroencephalograph. Then there is a possibility to display graphs of change in time of signals
from electrodes (EEG-x) (details in section § 5.1).
The item "DC21" (in development) can be used at work with fingerprint scanner Thus data
from the fingerprint device can be displayed in graphs (details in section § 5.2).
Item "Lock system" (in development) is used to lock of all toolbar buttons from stray
keystroke. To unlock the system, press the icon VibraImage " " in the top left corner of the screen.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
37
3.2.4 Menu «Action»
Menu "Action" (fig. 3.18) contains following items:
Fig. 3.23. Menu "Action"
Item "Pause" – stop last accepted frame of data in image area of windows.
Item "Reset" – reset all saved up information and statistics about frames and start new cycle
collection of information.
At work the program fixes an operating time with object of research, and in case of work with
AVI a file - time from the beginning of record. Having chosen item "Reset timers" (or corresponding
toolbar button), it is possible to reset in 0 counter of the current operating time, and at work with AVI
a file - to begin viewing record with the beginning.
At a choice of item "Measurement"(or corresponding toolbar button) the system makes
accumulation, averaging and a display of parameters for the specified time period. The results display
is made in the information panel in a mode «M». In the same place in seconds value of the averaging
period «Duration" is set.
Item «Start H 10s "are intended for accumulation and viewing of the frequency information
about psycho - emotional condition of person for 10 seconds. For viewing results, it is necessary to
open sheets "H" in the basic window (see Fig. 3.54).
Item "Start LD block" (or corresponding toolbar button) begin calculation of parameters of
a lie level in a “manual mode”. It is necessary to press this button again to stop calculation in a manual
mode. The moment of start calculation in a manual mode will be noted on graphs by a vertical green
line, the moment of stop calculation - by red line).
The item "Markers"is used at work with graphs and intended for draw on graphs the markers
(0-9) and markers of questions (RQ, CQ, GQ).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
38
3.2.5 Menu "Help"
Menu "Help" is in the main menu contains following items:
Fig. 3.24. Menu «Help»
Item "About VibraImage…" is intended to view the software version, the registered user
name (Owner), the key number protection (Serial) and expiry date of the license (Limited)
(fig. 3.25).
Fig. 3.25. Information about VibraImage and its owner
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
39
3.3 Image area control
VibraImage system allows the processing of a "live" video signal from the camera, and the
video data previously recorded and stored as AVI- file. By default, the system works with the signal
from your video camera. Switching between modes can be done through a toolbar buttons or through
the system menu "Settings - Video...".
Selecting an external video file via the file selection window, caused by using the command
"AVI file... " submenu "Settings - Video..." (see Fig. 3.19). Additionally, an external video file can
be loaded without sound using " AVI file (without sound)..." command. This mode is recommended
when working with VibraSound.
The main window of the basic VibraImage.exe module can be configured for observations in
several operating modes. The choice of an operating mode is made in the item "View" of the main
menu (fig. 3.26).
Fig. 3.26. Menu "View" for set working mode
Pause / start output of the current image is performed using the "Pause" command menu
"Action", or by using the corresponding toolbar buttons.
3.3.1 Choice of the main display mode
In the field of the image area (see Fig. 3.37 – 3.40), depending on the chosen mode (fig. 3.35),
the user can see the "real" video image, vibraimage, external vibraimage (aura), or external
vibraimage on real image.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
40
Item "Presets" menu "View" (fig. 3.26) is intended to choice one basic mode in image area.
In "VI" mode["VibraImage mode"] displays vibraimage of person. Color for every
image pixel depends on its amplitude or frequency of vibrations (fig. 3.37, 3.38).
In "AV" mode["Aura - Vibraimage mode"] the contour of the object allocated around
the vibraimage. Vibra-aura line size depends on medium line vibration amplitude.
Vibra-aura line color depends on maximum line vibration frequency inside vibraimage
contour (fig. 3.39, 3.40).
In "AR" mode["Aura on the Real image"] the vibra-aura of the person is shown around
his real image (fig. 3.40).
In "LD" mode["Lie Detector mode"] image area shows real object image.
Fig. 3.37. VI mode.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
41
Fig. 3.39. AV mode.
Fig. 3.40. AR mode.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
42
3.3.2 Submenu "Mode"
Item "Mode"(fig. 3.42) selects additional settings of information in image area. All items in
this submenu also duplicated in the additional toolbar (see Fig. 3.41, left panel). Disabling the menu
item "Toolbar VI", the user can remove the screen that extra toolbar.
Fig. 3.41. Submenu "Mode"
Note
Pressed buttons in toolbar correlated with windows in the area of images (fig. 3.42).
The maximum number of windows equal 13. To delete a window with the set image processing it is
enough to let off the corresponding button the of "Toolbar VI" panel.
Note, when approaching the mouse pointer to one of the images on the screen may be
displayed help list indicating the display mode of the window. Enable / disable output tips made in
the menu "View" – "Mode" in item "Tooltips" (see Fig 3.42.). If you switch on the "Title" menu item
than in the upper left corner of each image window will display the name of his mode.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
43
Fig. 3.42. Display concurrently multiple images windows with different processing methods
In "SRC" mode (the button ) shows source video from camera without processing
(fig. 3.43). It is additional possibility to display the aura on the real image of person
constructed on the analysis of pixels vibration amplitude (the button ) or frequency or
pixels vibration frequencies (the button ). The length of the beam vibra-aura in this
case will be determined by the average value of the points parameter in a row, and the
color of the beam vibra-aura – by the maximum value.
In "VI (2 Am)" (the button ) and "VI (2 F)" (the button ) modes display
vibraimage, processed during 2 frames and constructed on the basis of amplitude Am and
frequency F analysis of vibration. It is additional possibility to change color of
background image and to add vibra-aura to vibraimage (fig. 3.44).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
44
Fig. 3.43. Select mode of processing image
In "VI (10 Am)"(the button of the toolbar) and"VI (10 F)"(the button of the
toolbar) modes display vibraimage, processed during 10 frames and constructed on the
basis of amplitude Am and frequency F vibration analysis. It is the additional possibility
to change color of a background image and to add aura to vibraimage. The same result is
possible to receive if to bring the mouse pointer to a window of the chosen image and to
press the right button of a mouse (fig. 3.44).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
45
Fig. 3.44. Example, three type of images display. Switch on mode AR(F) and VI (10 F).
In "VI (N Am)"(the button of the toolbar) and"VI (N F)"(the button of the
toolbar) modes display vibraimage, processed during N frames and constructed on the
basis of amplitude Am and frequency F vibration analysis. The number of frames,
corresponding to parameter N, is set in "VI" information panel. It is additional possibility
to change color of background image and to add aura to vibraimage.
In "Delta Am"(the button ) and"Delta F"(the button ) display frame
difference on the basis of amplitude Am and frequency F vibration analysis in base
processing mode without filter preprocessing. It is additional possibility to change color
of background image.
Note. In this mode the vibra-aura will be based on the vibraimage which has been
accumulated for N frames!
In "View mode Delta FA"(the button ) and"View mode Delta FA"(the button
) modes display frame difference on the basis of amplitude Am and frequency F
vibration analysis in fast processing mode without filter preprocessing. It is additional
possibility to change color of background image.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
46
In "mode Am" visualization and calculation of object parameters processed by pixel
vibration amplitude.
In "mode F" visualization and calculation of object parameters processed by pixel
vibration frequency.
3.3.3 Graph display
Selecting item "Graphs"submenu "View" – "Toolbar" switches on / off graph windows with
display changes in time vibraimages parameters (see Fig 3.45.).
Fig. 3.45. Graph windows display
Selecting, changing of some parameters will be displayed in the graphs make in the
information panel in the "GR" mode (see Fig. 3.56). To display the graph of the parameter in the
graph window you want to switch on the item "Display" = YES.
The number at the beginning of each graph shows the current value, and the two digits at the
end of the current graph show minimum and maximum value for the interval over which the automatic
adjustment scale on the Y-axis (vertical) is made.
Scale the output of the X-axis plots (horizontal) is given in the "Graph":
Parameter "Period (s)" sets in seconds time of display of a graph part on the screen.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
47
Note, At viewing video file double click by mouse on the button changes value
"Period" so that on the screen the time axis corresponded to full length of video file.
Scale output on Y -axis (vertical) is determined for each graph separately in one of two modes:
If using mode "Auto" = YES, the vertical scale is automatically calculated.
If using the manual mode "Auto" = NO, the scale of the output of each individual graph
on the Y axis set parameters gMin (minimum value displayed on the screen) and gMax
(maximum value displayed on the screen), which the user must set yourself.
Fig. 3.46 Example, graph parameters for A1(fast).
Note (in development)
It is possible to playback recorded information (from AVI files) with graphs on the screen in
image area. For this purpose, it is necessary to execute the following actions:
Switch on "Graphs";
To bring the mouse pointer to interesting time on a time axis and twice to click the left
mouse button.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
48
When you select a show mode of plots "Diff. mode" = YES on the graph will be displayed
not the absolute value of the parameter (mode "Diff. mode" = NO), and the difference between the
current value of the parameter and its average level in the previous measurement. The "Averaging
(s)" parameter in this case sets the number of seconds for the interval by which averaging parameter
values change.
In the draw the parameter values changes on the screen, the user can use two display modes:
No pre-filtering values ("Graph2" mode = NO).
With advanced filtering parameter ("Graph2" mode = YES). In this case, the parameters
"HF.flt." and "LF.flt." is set in % of the incoming frequency the filter cutoff frequency
for high (low) frequency for Battervort.
At the same time for easy viewing in the Histogram window displays three windows with the
results of the frequency analysis (see Fig. 3.47). The first screen displays the frequency analysis
vibraimage across the frame (red – amplitude, green – frequency of points vibration). In the second
window displays the traditional frequency analysis in 1 second human vibraimage, and the third – the
results of frequency analysis (with the use of the Fast Fourier transform) to change in time of the two
options that are selected in the "GR" information panel. Each parameter has the following settings:
"Green" – Spectrum Fourier parameter changes in time displaying graphs of green
color in the third window;
"Red" – Spectrum Fourier parameter changes in time displaying graphics red color
in the third window;
Fig. 3.47. Histogram window
3.3.4 Graph analyze
Item "Start H 10s" are intended for accumulation and viewing of the frequency information
about psycho-emotional condition of person for 10 seconds. For viewing results, it is necessary to
open sheets "H" in the basic window (see Fig. 3.48).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
49
Fig. 3.48. Frequency analyses results
Note, the results of frequency analysis are automatically saved in the selected file folder in
the file Data_histH.png.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
50
3.4 Toolbar
All toolbar buttons (Fig. 3.49) duplicated the corresponding items in the menu system. When
the tool tip determines the assignment of toolbar buttons.
Note, the selected toolbar button is highlighted in color or volume, depending on the main
window style.
Fig. 3.49. Toolbar.
– "Save current image" (Menu "File");
– "AVI: Start Capture" (Menu "File"). For stop AVI files recording needs push on
this button again
– "Open AVI file" (Menu "File");
– Camera – video from camera;
– "Stop/Start" (Menu "Action");
– "VI" mode (Menu "View");
– "AV" mode (Menu "View");
– "AR" mode (Menu "View");
– "LD" mode (Menu "View");
– Reset timer of video files to "0" (Menu "Action");
– Reset all accumulated information about frame difference. Start accumulation again
after reset. (Menu "Action");
– "Measurement" mode of accumulation and averaging of parameters for the certain
period (Menu "Action");
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
51
– "Start LD mode" to begin/stop data processing for a "Lie detector" mode (Menu
"Action");
– "Markers RQ, CQ, GQ" are used in Lie detection mode and serve for
installation markers on graphs at the time of "certain" type questions
– button which allows to open the database folder where you saved the images and
all results.
3.5 Vibraimage parameters
During the work VibraImage program calculates the following parameters:
The group of parameters A1-A4 registers amplitude of vibrations:
А1 – Frame difference between two consecutive frames
А2 – Frame difference accumulated in 10 consecutive frames
А3 – Frame difference accumulated in N consecutive frames
А4 – Value of parameter A1 filtered on 10 frames
The group of parameters F1-F9 registers frequency of vibrations (amount of changing points):
F1 – Calculated value of changed signal pixels amount in 2 consecutive frames
F1
(fast)
Calculated value of changed signal pixels amount in frames difference in fast
processing mode
dF1
(fast)
The average value of changes in the quantity of elements (the increment) for F1
(fast) parameter
F2 – Averaged value of changed signal pixels amount in 10 consecutive frames
F3 – Average value of elements quantity which have changed for the period of N frames
F4 – Changed pixels maximum frequency during N processed frames
F5 – Current tension level (%). Ratio of "high" frequency density to "low" frequency for
parameter F1. It's speed of element changing in frames difference.
F5
(fast)
The average value of the rate of elements change in the fast processing mode
calculation
F6 – Inhibition parameter. Average value of the F1 parameter period (in seconds),
determined during period F6N. Value of parameter F6N is set in section [Filters]
an "S" information panel and defines quantity of the frame processed in Fast
Processing mode
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
52
F7 – Root-mean-square deviation for F6 parameter
F8 – Not average (current) value of F6 parameter (in seconds), showing the current time
period of F1 parameter changing
F9 – Neuroticism parameter
The group of parameters S1 – S7 registers symmetry of vibrations between left and right parts of
person body:
S1 – Ratio (symmetry) of amplitude left to the right changed pixels inside the object in 2
consecutive frames
S2 – Difference between the left and right average amplitude of object vibration in 10
frames
S3 – Difference between the left and right average amplitude of object vibration in N
frames
S4 – Ratio of the changed pixels quantity in the left part of object to the changed pixels
in the right part in 2 consecutive frames
S5 – Ratio of the changed pixels quantity in the left object part to the changed pixels
quantity in the right object part calculated in 10 frames
S6 – Ratio of the changed pixels quantity in the left object part to the changed pixels
quantity in the right object part calculated in N frames
S7 – Difference between the maximal frequency of vibrations of the left and right object
parts in N frames
The group of parameters P1-P30 registers features of mathematical Processing of vibrations:
P1 – Dispersion of vibration density for frequency distribution at 10 processing frames
P2 – Dispersion of vibration density for frequency distribution at N processing frames
P3 – Center density distribution displacement of frequency at 10 processing frames
P4 – Center density distribution displacement of frequency at N processing frames
Р5 – Level of lie
Р6 – Level of stress. P6A – calculation of parameter is executed on vibration amplitude,
P6F – on vibration frequency.
Р7 – Level of aggression. P7A – calculation of parameter is executed on points vibration
amplitude, P7F – on points vibration frequency.
Р8 – Level of energetic. P8A – calculation of parameter is executed on points vibration
amplitude, P8F – on points vibration frequency.
Р9 – Level of information entropy (on base of Shannon theory). P9A – calculation of
parameter is executed on points vibration amplitude, P9F – on points vibration
frequency.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
53
Р10 – Entropy index. P10A – calculation of parameter is executed on points vibration
amplitude, P10F – on points vibration frequency.
P11 - Antikurtosis (æ). Information theory parameter characterized density distribution
form.
Р12 – Level of classic thermodynamics entropy (on base of Helmholtz theory). P12A –
calculation of parameter is executed on points vibration amplitude, P12F – on points
vibration frequency.
P13 – Characterizes shift of the histogram in the right part (high frequencies). Thus,
parameters define color of active vibraimage pointer. Vibraimage pointer is active if
its brightness move than "Level L" value.
P14 – Control parameter. Define relation between area of active vibraimage pointer for
install threshold of active vibraimage pointer ("Level S" parameters). Thus if the
number of active points grows, than the parameter value increases and danger level
also increases.
P15 – Control parameter. Define relation between area of active vibraimage pointer for full
frame square. Vibraimage pointer is active if its brightness move than «Level L"
value.
P16 – Compatibility for 2 person. Calculated on frequency histogram analysis
(concurrence with normal distribution) (fig. 3.50, 3.51). If the frame one person – it
parameter "Balance".
P17 – Compatibility for 2 person. Calculated on aura symmetry analysis. If the frame one
person – it parameter "Charm".
Fig. 3.50. Correct position of people at
check of compatibility.
Fig. 3.51. Incorrect position of people at
check of compatibility.
P18 – Average compatibility by P16 and P17 parameters. 5 gradations are distinguished:
love, sympathy, indifference, hostility, hatred. If the frame one person – it parameter
"Selfregulation".
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
54
Р19 - Suspect level
Р20 - Quantity indicator of a degree of change psycho physiology parameters in view of
various factors of the measured parameters importance since the part of parameters
is accelerated, and others are slowed down during one reaction.
Р21 - Parameter "Health" (Health level for general oncology);
Р22 - Parameter "Health" (Health level for prostate oncology);
Р23 - the average of the "Health" (Mean value of health level);
Р24 - Parameter "Sleepiness" is normalized value of the P17 to the parameter F3;
Р25 - characterizes a sleepiness state of a person on variability of parameter P17.
Р26 - Extraversion level
Р27 - Stability level
P28 - Satisfaction level
P29 - Depression level
P30 - Happiness level
Parameters X1 – X5. In VibraImage program the user can form itself formulas for
calculation of new parameters of vibraimage, using any vibraimage parameters listing above.
3.5.1 Т1-Т12 parameters
For improvement of calculation, analysis and data compatibility vibraimage includes
additional complex T1 – T12 parameters having psychophysiological sense. Complex vibraimage
parameters represent psychophysiological information about a person and informative component of
these options depends not only on calculation algorithms, but also depends on targets and conditions
of vibraimage system applications. For example, under different test conditions (state of rest, stress,
movement…), the same parameters can provide information about the physiological and
psychological state of a person, as well as the suspicious level of person.
The set of parameters T1 – T12 is selected so that a maximum information records all
micromotion human head. In this case the name of each parameter Ti characterizes various
physiological characteristics depending on the vibraimage system application. The name isn’t primary
characteristics for said vibraimage parameter, it can be considered as suppositive and the formula by
which this parameter is determined has more correct sense. Despite the suppositive names, given
description uses the following (historically developed) range of parameters:
Т1 – Aggression (Р7);
Т2 – Stress (Р6);
Т3 – Tension/Anxiety (F5X);
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
55
Т4 – Suspect (Р19);
Т5 – Balance (Р16);
Т6 – Charm (Р17);
Т7 – Energy (Р8);
Т8 – Selfregulation (Р18);
Т9 – Inhibition (F6);
Т10 – Neuroticism (F9);
Т11 – Depression (P29, DP);
T12 – Happiness (P30, HP).
3.6 Information panel
Indication of information panel (fig. 3.52) depends on using mode:
Fig. 3.52. Information panel tables menu
In the mode information about adjustments of system and results of data vibraimage
processing is displayed;
In the mode settings for LD the mode parameters are displayed.
In the mode the average values of vibraimage parameters which have been calculated
and are average for the certain period are displayed;
In the mode the correlation parameters are configured;
In the mode vibraimage parameters selected for graphs are displayed and stood;
In the mode settings of basic parameters for work with VibraImage are configured;
In the mode input and selection of the demographic information and a folder for
archive storage is configured;
Note, Values of parameters in fields which are allocated by a green font, can be changed
by the user (fig. 3.53, parameters N, K, L – it is possible to change in Information table). For this
purpose, it is necessary to bring the mouse pointer to the chosen field and twice to click the left button
of a mouse.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
56
3.6.1 Information panel. VI mode.
In the "VI" mode information panel (fig. 3.53) displays following information:
Frame rate:
"In" – Number of the frames per second, received from the video source;
"Fast processing" – Maximum number of the processed frames per second used for
calculation. Selected by user;
"Base processing" – Number of the processed frames per second used in base algorithm.
Selected by user;
"Video Timer" – For camera mode- displays time of supervision. For recorded video - time
of current video-file record. For viewing a video-file - time from the file beginning);
"Stream errors" – The counter of mistakes which increases if time between the next accepted
frame astably. This mistake can arise, if productivity of a computer suffices or poor-quality
video is loaded;
Info:
N – Number of the frames for accumulation. Selected by user;
L – Palette Threshold. Defines a threshold in the displayed image, value of brightness less
threshold is considered «black». Selected by user;
Width and Height– Displays the current video camera or AVI file resolution;
Statistics:
IntegratedN(Am – Average frame amplitude vibraimage intensity processed for the N
frames.;
IntegratedN(f Average frame frequency vibraimage intensity processed for the N frames;
"Critical level %" – threshold of a psychoemotional status of the person exposed in % in case
of which exceeding on the remote terminal the warning message will be issued;
"Suspect" – Calculated level of suspect for object in frame;
"Aggression" – Calculated level of anger for object in frame;
"Stress" – Calculated level of stress for object in frame;
"Tension" – Calculated level of tension for object in frame;
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
57
Audio:
"Level" – current level of audio signal.
Fig. 3.53. Information panel in the VI mode.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
58
3.6.2 Information panel. M mode.
In "M" mode an information panel (fig. 3.54) detects current and average for the period values
of psychophysiological parameters and their deviation from the established norm. The basic targets
of the given mode are use of vibraimage system for medical (physiology) diagnostics and
psychological researches and testing.
a) b)
Fig. 3.54. M mode of information panel
Value of the averaging period is set in seconds in a field "Duration". Start of the beginning
of information accumulation is made by a choice of item "Measurement" the menu "Action" or
pressing of the toolbar button . After start of an accumulation and averaging mode in the top
of information panel there is a running line "Progress", displaying a course of data accumulation
process.
с
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
59
Information panel in "M" mode shows the following information:
Basic T1 – T12 parameters describing psycho-emotional condition of the person:
Aggression, Stress, Tension/Anxiety, Suspect, Balance, Charm, Energy, Self regulation,
Inhibition, Neuroticism, Depression, Happiness.
VibraImage parameters A1 – A4, F1 – F9, S1 – S7, P1 – P4, Р21 – Р30;
Fast processing VibraImage parameters A1 fast, A4 fast, F1 fast, F5 fast;
For each parameters displays the following numerical values:
V – The value of the parameter average for the set period
S – root-mean-square deviation of parameter
VI – The variability of the parameter over a specified period
cMin – The minimal value of parameter for the period
cMax – The maximal value of parameter for the period
NMin – The minimal value of parameter for a normal condition of the
person
NMax – The maximal value of parameter for a normal condition of the
person
Note
Values of cMin, cMax parameter, are displayed only when measurement mode "M" starts and
the information for the specified period of time is saved up.
Note, after ending of the information accumulation some lines of an information panel can be
allocated by color:
– parameters, which values less than the set limits are allocated.
– parameters, which values more than the set limits are allocated.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
60
3.6.3 Information panel. LD mode.
In the mode "LD" information panel (See Fig 3.55) defines the basic "lie
detection"information processing mode and displays the following information :
VibraImage parameters A1 – A4, F1 – F9, S1 – S7, P1 – P4;
Fast processing VibraImage parameters A1 fast, A4 fast, F1 fast, F5 fast;
For each parameters displays the following numerical values:
V – Current parameter value;
cMin – The minimal value of parameter for the period
cMax – The maximal value of parameter for the period
bMin – The average basic minimal value of parameter for a normal condition of
the person
bMax – The average basic maximal value of parameter for a normal condition of
the person
Note
Values of cMin, cMax, bMin and bMax parameter, are displayed only when "LD mode" has
been began/ In other case that value equal "0".
For each parameter set following numerical values, which using in Lie detector calculation:
Calculate Yes – this parameter using in LD level calculation, No- not using
R1V "Weight" of parameter (Rate1) if its current value became more than
the set base maximum bMax OR became less than the set base
minimum bMin. Use in Р5 parameter calculation.
R2V "Weight" of parameter (Rate2) if its current value became more than
the set base maximum bMax AND became less than the set base
minimum bMin. Use in Р5 parameter calculation.
R1C "Weight" of parameter (Rate1) if its current value became more than
the set base maximum bMax OR became less than the set base
minimum bMin. Use in Р20 parameter calculation.
R2C "Weight" of parameter (Rate2) if its current value became more than
the set base maximum bMax AND became less than the set base
minimum bMin. Use in Р20 parameter calculation.
Level In % determines on how many value of parameter should exceed the
set limits that the system "considered" this change.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
61
Fig. 3.55. Information panel in LD mode. Explanation of the parameters bMax, bMin, cMax, cMin.
3.6.4 Information panel. GR mode.
The "GR" information panel (See Fig 3.56) allows you to customize the output graphs of
parameters changes and displays the following information:
Fig. 3.56. "GR" mode of information panel.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
62
"Graph" section
"Period (s)" – define graphs visualized period (in seconds) on the screen
"Average (s)" – specifies the number of seconds in interval by which averaging
parameter values is made.
Test signal sin(2π*nt);
"Integral" section
Total intensity of the points oscillation amplitude across the frame, accumulated over 2,
10 and N frames: Integrated2(Am), Integrated10(Am), IntegratedN(Am);
Total intensity of the points oscillation frequency across the frame, accumulated ove 2,
10 and N frames: Integrated2(F), Integrated10(F), IntegratedN(F);
VibraImage parameters A1 – A4, F1 – F9, S1 – S7, P1 – P25;
Fast processing VibraImage parameters A1 fast, A4 fast, F1 fast, F5 fast;
Corelation parameters С1 – С4;
User programming parameters Х1 – Х5;
For each parameters displays the following values and settings:
V – Current value of parameter
Show – Show graph – Yes, delete graph – No
Graph2 – Graph2 = Yes – graph line will show with using filters. Graph2
= No – filter no used.
Diff. mode – Choice of this mode – YES, graph will show difference between
current value of parameter and its average level for Diff time.
Choice of this mode – NO, graph will show current value of
parameter
Auto – When the parameter set "Yes", calculation of the scale on the Y
axis of the graph make automatically.
gMin – Defines the minimal value of parameter shown on the screen
gMax – Defines the maximum value of parameter shown on the screen
HF.flt.% The filter of high frequencies on Battervort. Frequency of a cut
is set in % from entering graph frequency.
LF.flt.% The filter of low frequencies on Battervort. Frequency of a cut
is set in % from entering graph frequency.
GR. Selected parameter displays in down spectrum histogram by
green graph (fig. 3.57)
Red Selected parameter displays in down spectrum histogram by red
graph (fig. 3.57)
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
63
Fig. 3.57. FFT diagram
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
64
3.6.5 Information panel. С mode.
Information panel in "C"mode (fig. 3.58) allows setting the mode "Correlation"and displays
the following information:
The correlation between parameters is calculated on base Pearson method. If one of parameter
is select in his line draw field. Select this parameter to check the correlation is performed by
double-clicking the left mouse button over this field.
Fig. 3.58. "C" mode of information panel.
"Settings" section:
"Enable correlation" – defines the switch on/off "C"mode;
"Mediane" – define what parameter value (average or mediane) will use in correlation
calculation.
"Period" – defines what period occurs correlation parameters;
"Auto shift" – determines the maximum shift in time not influencing correlation
coefficient,
"Sort" – allows you to rank display parameters of the maximum current value of the
correlation coefficient to a minimum
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
65
"HF flt", "LF flt" and "Average flt" – defines mode for the additional processing (filtering)
of source data before calculation.
"Correlation" section:
Total intensity of the points oscillation amplitude across the frame, accumulated over 2,
10 and N frames: Integrated2(Am), Integrated10(Am), IntegratedN(Am);
Total intensity of the points oscillation frequency across the frame, accumulated ove 2,
10 and N frames: Integrated2(F), Integrated10(F), IntegratedN(F);
VibraImage parameters A1 – A4, F1 – F9, S1 – S7, P1 – P30;
Fast processing VibraImage parameters A1 fast, A4 fast, F1 fast, F5 fast;
Test signal sin(2π*nt);
Corelation parameter С1 – С4. Frame is divided into four zones and parameter estimation
is performed between zones. For example, when using mobile versions VIMobile
estimated background vibration (vibration due to human brush), and the man himself
vibration.
User programming parameters Х1 – Х5;
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
66
3.6.6 Information panel. S mode.
Information panel in "S"mode (fig. 3.61) allows adjusting vibraimage parameters and displays
the following information:
Frame rate
Fast processing Frequency (fps) for processing «fast"parameters of vibraimage,
noted by a word "fast"
Base processing Frequency (fps) for processing "base" parameters of
vibraimage, noted by a word "base"
FPS proc.period Frequency of the frames (fps) during calculation period
Downrate Reduce input frame rate. At value 3, will be processed every
third frame.
Main settings
N(2) Minimum number of accumulated frames. By default, 2
N(10) Average number of accumulated frames. By default, 10
N Maximum number of accumulated frames. By default, 100
K Gain factor.
L Threshold of a palette. Defines a threshold of displayed image,
value of less brightness considers as "black"
Apply global filters If this parameter is "Yes", than other parameters calculated with
filtering.
Cores The number of simultaneously displayed cameras. Depending
on the dongle less than 10.
Filters
Single points Removes single points, surrounded by black
Extended It is intended for reduction of noise of a video camera. Delete
video noise in bit. By default, 8.
This filter is important, when the object is motionless, and
values changed because of camera noise.
Extended (fast) Delete video noise for fast processing.
Stretch Scale normalization filter to a range 0 – 255 after its
"trimming" by filter Extended
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
67
Max speed contour At the included mode, calculation fast parameters are made
only inside of aura contour, at switched off – on the whole
frame.
Am scale Multiplication factor used for vibraimage visualization in a
"amplitude" mode
Space Reduce vibraimage on borders of motionless contrast objects.
Color image No – Black and white real image in image area. Yes – color
image in image area.
Crops
Crop X, Crop Y If real image size more than 640x480 pixels, than will be use
only 640 x 480 pixels from centre part of image.
Crop X pos, Crop Y
pos
When cropping images define the coordinates (the position of
the upper left corner) the clipping region.
F6
F6 HF Sets in % frequency of a cut for the filter of high frequencies at
processing F1_fast parameter.
F6 LF Sets in % frequency of a cut for the filter of low frequencies at
processing F1_fast parameter.
F6 N Number of averaging frame at calculation of F6 parameter
FPS filter It is used for exact synchronization with a binding to the
concrete frame at work with Avi files. Frequency of the input
frame from the camera divided on set Base processing frequency
and for processing will undertake each N frame.
E-Monster Switch to the E-monster mode. The program opens the person
face deformed by latent emotions though externally he can
constrain these emotions. If the emotional condition of the
person is like to normal, then the the program image is like to
real video. Accordingly, than more emotions overflows the
person, then more especially deformed his image in Monsters
Detector mode (E-Monster).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
68
Fig. 3.59. Face in E-monster mode
Auto downrate Automatic calculation of Downrate parameter is made in view
of frequency of the input frames, Base processing frequency and
computing capacity of a computer.
Fixed contour In this mode vibra-aura around the human contour will be built
around a fixed path, and not to repeat the contours of the body.
Stab. Х Image stabilization in the X coordinate is entered when
significant vibrations image on the X axis
Stab. Y Image stabilization in the Y coordinate is entered when
significant vibrations image on the Y axis
Suspicious thresholds
Ag, St, Tn
Suspicious level in the Aggression parameters (Ag), "Stress"
(St), "Tension" (Tn) is set. When exceeding level of danger the
system gives out a sound signal and fixes a frame.
Disable Note: Canceling of parameter calculation is use for increase
calculation speed of other parameters.
Disable Am Canceling of points fluctuation amplitudes calculation
Disable F Canceling of points fluctuation frequencies calculation
Disable 2x(fast) Canceling of 2 frames parameters fast calculation
Disable VI(10) Canceling of 10 frames parameters calculation
Disable VI(2) Canceling of 2 frames parameters calculation
Disable FFT Canceling of Fast Fourier Transformation frequency
processing
Disable Entropy Canceling of Entropy processing
Disable Audio Canceling audio analysis
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
69
Motion detection
Motion detector Delete emotion calculation for object with motion amount less
than threshold
Level Threshold level of Integrated10 for emotion calculation.
Auto reset Reset emotion calculation for macro movement
Skip frames Skip frames with the frame difference more than threshold.
Lie detection
Enable Enable LD mode.
Stat periods Before you begin the process of "lie detection" system during
the "Base period" (in seconds) collects information to
determine the maximum and minimum current values of human
parameters that then at "lie detection" time during the "Stat
period" define "abnormal"change individual values
parameters.
Base periods
Lie threshold Threshold (in %) for the detection of lie level in view of every
calculated parameters and their «weights»
Audio sens. (s) After the ending of answer the system continues to expect "lie"
calculation during the specified time interval.
Audio level The sound level is used to start / stop lies detection process in
the "Audio" mode.
Opposite mode Alternative method of lie level calculation.
LD mode: Selection of mode for lie detection
Audio Calculation of lie level starts when the level of entrance audio
signal exceeds the established threshold. LD calculation stops,
when the level of audio signal becomes less than the
established threshold
Manual Accumulation of the information is made in time "Base
periods". Calculation of lie level is made only after pressing
button "Start LD" , the end of processing – after repeated
pressing this button
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
70
Auto Calculation of a lie level works constantly, current values of
parameters (Stat period) are compared to values processed for
previous Base period
Compare Off – at the analysis of lie, as test, the interval "Base periods"
directly till the moment of started lie detection is used.
On – at the analysis of lie, as test, the interval "Base periods"
which has been marked by the user beforehand is used. When
the user includes accumulation the preliminary information, in
this field value "Capture"
Text Switch on/off display "text questions" in "LD Question"
window
AVG filter
Anger Number of frames for aggression level averaging
Stress Number of frames for stress level averaging
Tension Number of frames for tension level averaging
Suspicious Number of frames for suspect level averaging
Macro mode
Macro mode Define on base of which formula danger level calculated. NO –
danger level calculated on base of Anger, Stress and Tension
levels. YES – danger level calculated on base of P13, P14 and
P15 parameters values.
Level L Threshold of a palette for danger calculation only (not for
displayed image. threshold of displayed image define
parameter L). Value of less brightness considers as "black" and
not used in danger calculation.
Level S Threshold of a area (in % from full frame square). Defines area
of "active brightness" pixels. If area of pixels (in %), which
brightness more than «Level L"value, less than "Level S"
value, than danger parameters in Status window equal 0.
Aura mode Reserved for future use
Macro mode + Yes – the danger level is considered for every single person in
the frame.
No – the danger level is averaged over the entire frame.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
71
Face detection
Face detection Yes – face detection mode is used. No – without face detection
Detection quality Quality of face capture. 1 – capture one large person face in
the frame (loading of the processor is minimal), 4 – search of
all (even small) persons face in the frame (loading of the
processor is maximal).
Scale 1: X Sets the aspect ratio of the picture before detection of persons
Min size
Max size
Sets in pixels the size of rectangle for search of persons
Config The program gives the user an opportunity of loading the new
algorithms of person search. In the given line the path to a file
of new search algorithm is displayed. In more detail procedure
of loading of new algorithm is described in section 6.2 "Macro
Mode"
Draw No – not draw rectangle around face, Yes – draw rectangle
around more danger single person, All – draw rectangle for all
danger person in frame. For non-danger person rectangle draw
green color, but if person suspect level more than "Critical
level", than rectangle draw red color.
Quality test
Enable Switch on mode of automatical check of image quality (see p.
2.3.1)
Light level Parameter use for define image noise level when illumination is
low.
FPS max, FPS min Maximum and Minimum allowable input frame rate.
Face delay This parameter determines how long (in seconds) the program
can not recognize a human face in the frame before you will get
an error message
Alerts
Critical level % Stands critical (upper) level of emotion parameters for alarm
signals
Customer level % if suspect level lower than cutomer level then person will be
detected as "dangerous"
Area threshold%,
Area level %
Used to account for the small area factor of moving objects
relative to the frame area during the suspect level calculation.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
72
Auto capture image
Auto capture image (s) At excess of the preset level psycho-emotion danger in the
specified catalogue BMP files of the "dangerous" person from
display screen will saved automatically. Record will be made
one time for the specified quantity of seconds. (see p. 3.7.4)
Hide after (s) After this period in seconds captured images will not displayed
Save image files Determines to save or not photo file of "dangerous person"in
the database
Save face XML Save information about position "dangerous person" on image
Save faces Save image inside detected contour
Print suspect On/Off displaying parameters A (Agression), S (Stress), T
(Tension), Suspect on captured image
Fig. 3.60 Print suspect
Save original Save original image without vibraimage processing
Image format Choose format of saved image file (BMP, PNG, JPEG) By
default PNG.
Show N image At work in Macro mode in "Capture window" will be
consistently displayed N images of "dangerous" objects, but if
for the specified interval of time has passed some "suspicious"
objects.
Sound (Susp) Defines, the sound signal will be used at work if "danger"
person appear or not.
Sound (A), Sound (S),
Sound (T)
Level for sound of a audio signal at excess of aggression, stress
or suspect levels the setting limits.
Maker’s beep On/Off maker’s beep in LD mode
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
73
Reset beep On/Off reset sound beep.
Audio file upload Audio file
FTP Storage
enable FTP Switch on/off FTP network protocol
configuration file way for configuration file of FTP
Fn
X1-X5 In VibraImage the user can form itself formulas for calculation
of new parameters of vibraimage, using any vibraimage
parameters. For example (fig. 3.61).
Fig. 3.61 User’s formula for parameter X1 calculation
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
74
VibraSound
Disable std. sound
YES - VibraSound mode is switch on.
NO - VibraSound mode is switched off, the sound acts either
from a microphone or from a video file.
Vibra sound To switch on the VibraSound must select one of the values CG,
CR, HG, HR, SG, SR
If one of these items is chosen than VibraSound sound will be
switch on and will be modulated by curves of signal change in
one of frequency distribution windows (fig. 3.57). Letters C,
H, S define, from what window the signal for "sound" will be
used: C – the first window, H – the second, S – the third.
Letters G and R – show what color of graph will define
"modulation" of a sound: G – green color, R – red color.
Network service
Enable service sanction of information transfer to network between a computer
on which program VibraImage.exe is started, and the terminal.
Critical level %
Customer level %
Full video stream
Lower (customer) and higher (critical) threshold of psycho
emotional conditions of the person at which excess on the
removed terminal the warning message will be given and the
picture of danger object (if parameter "Full video stream" = NO)
is sent or the video information (if parameter "Full video stream"
= YES) will be transferred.
Compression When transferring video the compression will be applied.
Parameter value define the compression rate
Local TCP port VibraImage.exe program interrogates the given port for data
exchange with the terminal.
Remote host – name of the removed terminal
IP network address of terminal computer on which program
VINetStatus.exe is started.
TCP port, UDP port Ports for software of terminal, through which it changed by
information with the computer, on which started program
VibraImage.exe. Through UDP port goes an exchange by short
messages. Through TCP port goes an issue video data.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
75
Capture
Max length (s) Defines the maximal length (in seconds) for recorded video file.
After file limit finished and closed, a new file creates.
Purge old files Defines system action when the empty space on a hard disk will
finish. "YES" – the oldest video files will be removed.
Timer The system can begin record at the appointed time.
Capture channel Mode of vibraimage video (SRC, SRCAm, SRCF etc.)
The VibraImage system implemented the ability to work in a complex network monitoring
mode, when on the local module (a computer connected to the camera) VibraImage.exe is running,
which makes the diagnosis and condition of the person on the psycho-physiological parameters, and
on the other computer (terminal) one of the two modules running VINetStatus.exe or
VINetServer.exe.
More detailed information about the settings for the network mode operation, see the
"Behavior Detection System 8 PRO", http://www.psymaker.com/downloads/VI8_1ManualEng.pdf
section "Network monitoring"
3.6.7 Information panel. DB mode.
In "DB"mode information panel (see Fig 3.62.) used to manage the experimental data records
and displays the following information:
Fig. 3.62. DB panel.
"DB folder" – Way to the database folder for written video files and files of statistics;
"Selected record" – Data on current object of research. List of all saved entries will be
displayed below.
"New record" – Information about the object of research is introduced in any form by
double-clicking the left mouse button over this field.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
76
3.7 Save of measurements results
Note, until the specified database folder not set, then AVI file recording, BMP and other files,
settings and results saving to the archive will be blocked. All results are stored in a single "_Default"
folder created in the directory where the program \ VibraImage10 \ database \ installed.
The way to the catalogue of an archive database where video files, files of images and files of
statistics will be save, is specified in a field "DB folder" in "DB" information panel. The list of
objects, the information about which is in the specified catalogue displays as the list in the bottom of
an information panel. In line "Selected record" show curent record with which the system operates in
a given time.
Item "New records...” use for a new entry into the database. A further saving of files in the
archive will be made in the folder associated with the name of your entry. To make a new entry in
the archive, you must bring the mouse pointer to the line "New record" and double-click the left
mouse button.
Fig. 3.63. Example, new records is created in database
3.7.1 Save of current images
The structured store of observable images in format BMP files according to the entered
demographic data is carried out with the help of a command "Image capture …" menu "File" or
the corresponding button of the toolbar.
NOTE, in archive as separate BMP files will be written down images from all open windows
in the field of supervision. For example, in the field of supervision 3 windows with processing image
are open (VINA and VIN
F) and in archive result 2 files of images will be save:
2014-04-22 11_48_51_vi1_F.bmp
2014-04-22 11_48_51_vi1_A.bmp
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
77
3.7.2 Save of video file
Save of the current image which appears in the basic window, in format AVI file is carried
out with the help of a command "AVI: Start Capture" menu "File". Stop AVI- file recording
process is carried out repeatedly selecting this menu item. The same actions can be executed with the
help of the corresponding button of the toolbar.
Note, that if in the image area open multiple windows with different ways vibraimage
processing (see Figure 3.64), the user in the section "Capture channel" of informational column in
the "S" mode should be selected from any open window will be recorded the information to videofile.
Note, data is written to a file with all of the switched processing modes. If you want to record
only the video image without processing, it is necessary to select SRC recording channel.
Fig. 3.64. Select vibraimage channel for videofile saving
For increase of video files recording reliability in "S" information panel designed the field
"Max length (s)" (records in seconds). If record lasts over the specified interval current AVI the file
will be closed and save on a disk, and record will be continued in a new file. At filling the whole disk
if the set "Purge old files" parameter the record of new video-files will be made atop of old. The
first "oldest" will leave by date of creation video-files.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
78
3.7.3 Save of results and settings files
1. After completion of the process of "Measure" (mode "M") and collect information about
the psycho – emotional state of a person in a specific database directory the following files are
automatically recorded:
Data_time_histH.xml – system settings and change the basic parameters of the psycho -
emotional state of a person in the course of the experiment.
Data_time_M.xls – report file with results of analysis psycho -emotional state of a person
for the specified period.
2. In addition the user can save in an external file with extension *.xml system settings at the
moment of the beginning of the information analization.
Item "Save settings as …" the menu "File" is intended for saving the current system settings
to external XML file.
Item "Load settings …" is intended for loading before saving settings from external
XML file.
3. After completing the questionnaire in lie detection mode automatically in the selected
database directory \ VibraImage10 \ Database \ *** creates files with the test results :
Data_time_histT.png – an analysis of changes in the human psycho - emotional state
at the time of testing.
Data_time_histH.xml – system settings and change the basic parameters of the psycho
-emotional state of a person
Data_time_LD.txt – lie detector report and result files
Data_time_row.txt – Full record values recorded vibraimage system parameters. This
file can be used for statistical research and testing of algorithms for determining the
psychophysical and psychoemotional human condition.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
79
3.7.4 Auto capture image in Macro mode
In Macro mode there is some settings for auto capture image (fig. 3.65) for automatically
saving image files of the "dangerous" person at excess of the set level psycho-emotion danger in the
specified catalogue:
Fig. 3.65 Submenu auto capture image in S information panel.
Item "Auto capture image" configure the number of images saved from the screen in a time
period "Hide after (s)" in seconds.
Item "Save image files" determines whether stored in the database directory photo file
of "dangerous person"or not.
Item "Save face XML" Suspicious person face’s data (fig. 3.66 c) or not.
Item "Save faces" determines save image with a detected «suspicious"person in frame
(fig. 3.66 b) or not.
Item "Save original" determines save original image (fig 3.66 a) or not.
Item "Save settings as…" the menu "File" is intended for saving the current system settings
to external XML file (fig 3.66 d).
Item "Image format" determines format of auto capture image (PNG, JPG or BMP).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
80
a) Original image b) Image with a detected "suspicious"
person in frame
c) "Suspicious" person face d) Suspicious person face’s data
Fig.3.66 Result files of Macro mode
Suspicious person face’s data file fig.3.66 (d) includes the following information:
<face face_rect="274,127,461,326 " – facial coordinates in pixels of left down and right
up points from the frame;
level = "0,631029" – suspicious level of captured person;
img_size = "640,480" /> frame size in pixels.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
81
4 The basic modes of the VibraImage system
VibraImage system has 3 basic operation mode:
1. Micro mode – it is intended for supervision, research and the analysis psycho emotional
conditions of the one person in the frame.
2. Macro mode – it is intended for supervision, research and the analysis psycho emotional
conditions of the people in crowd.
3. "Lie detector"or LD mode - it is intended for lie detection of the one person in the frame
center.
4. Mix mode – it is intended for supervision, research and the analysis psycho emotional
conditions of the people in crowd with accuracy close to Micro mode.
The user can choose a system operating mode, having set options by default, selecting the
appropriate line in the sub-menu "Settings" – "Default"(see Fig. 4.1).
Fig. 4.1 Select "Micro" mode
When you select one of the basic modes of operation (micro, macro or lie detection) and load
its default settings, the system automatically displays only the necessary window (Fig. 4.2).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
82
Fig. 4.2. "Micro" mode uploaded
4.1 Micro mode. Emotions (personality traits) definition
The main targets of the MICRO mode ("M") are receiving significant psychoemotional and
psychophysiological personality portrait and carrying out functional diagnostics test person. It is
possible to use MICRO mode for security system applications and identify suspicious people on the
protected objects. Usually, for security system applications MICRO mode is using without M button,
and detection of the suspicious level (Suspect indicator) is based on calculating T4 parameter in real
time mode.
MICRO mode gives highest accuracy in the measurement of psychophysiological parameters
relative to Mix and Macro modes. With correct vibraimage settings is possible to achive minimal
error rates as (2 % < FRR < 10 %) in the MICRO mode.
It is known that the psychoemotional and psychophysiological state of a person is constantly
changing under the influence of external and internal factors. In the "M" mode are measured average
values of psychophysiological parameters T1 – T12 (emotion12print) for the fixed time period and
their deviation from the established norms.
There are different science opinions about emotions, behavior and personality traits. General
description about these points is described in Wikipedia and science publications, see
https://en.wikipedia.org/wiki/Emotion
https://en.wikipedia.org/wiki/Behavior
https://en.wikipedia.org/wiki/Personality_psychology
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
83
Elsys Corp suggested own concept about personality and mental features which includes
several main points:
1. Preferable math methods than words for personality traits indication, because math formula
gives only one sense for indication. The word has different interpretation because different users give
different sense to the same word.
2. The list with formulas for indication of every vibraimage emotion12print algorithm is
described in VibraStat program manual. It is not necessary to obstruct the current Manual by unused
for typical user information.
3. For T1 – T12 parameters was selected 4 main parameters for indication positive emotions
(personality traits), 4 main parameters for indication negative emotions (personality traits) and 2 main
parameters for indication of physiological characteristics. In our understanding we selected the most
important and informative parameters for selected groups and used the terms based on current
psychology science level.
4. From vibraimage point of view we suggested the different math methods for head vibration
calculation because the main math task of vibraimage is to detect all parameters of head vibration so
as we supposed that head vibrations reflect all personality traits and emotions.
5. Of course the list of selected parameters is not finished. Based on customers’ requests is
possible to extend this list and add some parameters which are actual like sleepiness level or tiredness
etc. The most part of a new emotional parameters could be calculate based on existing emotion12print
(T1 – T12) after additional reseaches and statistics capturing.
The analysis determined the expectation M, standard deviation S, and variation V = S/M for
the following psychophysiological parameters measured in ("M") mode:
Т1 – Aggression (Р7)
This parameter is determined by the frequency histogram and represents the maximum
allocation of the frequency and SD vibration frequency of the human face. The higher value of the
maximum distribution and higher SD value gives the greater value of the parameter T1.
a) b)
Fig. 4.3 Agression; a) T1= 18 %, b) T1= 60 %
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
84
Т2 – Stress (Р6)
Parameter is determined by degree of the external vibraimage (vibra-aura) asymmetry, means
asymmetry of micromovements from the left and right parts of the person’s head. The great difference
in amplitude and frequency movements for the left and right parts of the face (head) characterizes the
increased T2 parameter level.
a) b)
Fig. 4.4 Stress; a) T2 = 17 %, b) T2 = 45 %
Т3 – Tension/Anxiety (F5X)
Parameter is determined by the relation of high-frequency part of a range of vibrations to the
general power in a range of micromovements frequency for human head. High value of high-
frequency vibrations density characterizes high value of the T3 parameter.
a) b)
Fig. 4.5 Tension; а) T3 = 28 %, б) T3 = 48 %
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
85
Т4 – Suspect (Р19)
The parameter is determined as the sum average of the first three conditionally negative
emotions (T1, T2, T3) and characterizes the general level of conditionally negative emotions in a
person status.
a) b)
Fig. 4.6 Suspect; a) T4 = 20 %, b) T4 = 65 %
Т5 – Balance (Р16)
The parameter is determined by the frequency histogram and characterizes the level of
similarity of the current frequency histogram to the Gaussian distribution law. The high level of
frequency histogram similarity to the normal law is characterized by a high level of balance, and
significant deviation from the Gaussian distribution is characterized by a low level of the parameter
T5.
a) b)
Fig. 4.7 Balance; a) Т5 = 10 %, b) Т5 = 80 %
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
86
Т6 – Charm (Р17)
The parameter is determined by the symmetry (left – right) of the head and face
micromovements, the maximum symmetry of movements (including frequency and amplitude)
represents a high level of charm T6.
a) b)
Fig. 4.8 Charm; a) Т6 = 85 %, b) Т6 = 40 %
Т7 – Energy (Р8);
The parameter is determined by the frequency histogram and characterizes the difference of
the maximum density of the vibration frequency and vibration frequency SD for the face and human
head. The higher value of the maximum density and lower SD or variation of vibration gives the
higher value of energy T7.
a) b)
Fig. 4.9 Energy; a) Т7 = 3 %, b) Т7 = 70 %
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
87
Т8 – Selfregulation (Р18);
The parameter is determined as the sum average for conditionally positive emotions (T5, T6)
and characterizes the general level of conditionally positive person emotions at the measurement time.
a) b)
Fig. 4.10 Selfregulation; а) Т8 = 30 %, б) Т8 = 80 %
Т9 – Inhibition (F6);
It has a real physical dimension (time in seconds) and characterizes the minimum time of the
person reaction for the shown event (the stimulus). The value of the parameter T1 = 0.1 means that
the reaction time is 0.1 s. The greater the reaction time corresponds to a higher level of inhibition.
a) b)
Fig. 4.11 Inhibition; a) Т9 = 12 %, b) Т9 = 25 %
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
88
Т10 – Neuroticism (F9).
The parameter characterizes the SD measured value of the inhibition level (T9) at the
measurement time (default 60 seconds). High level for inhibition SD of psychophysiological state
characterized by instability and indicates high level of neuroticism T10.
a) b)
Fig. 4.12 Neuroticism; a) Т10 = 10 %, b) Т10 = 35 %
Т11 – Depression (P29);
The parameter is determined by the frequency histogram. It characterizes the SD of histogram
and how much energy testee spend for the state. The high level of SD with big meaning energy of M
is characterized by a high level of depression. Depression will be minimally if vibro-aura has 1 colour.
a) b)
Fig. 4.11 Depression: a) Т11 = 16 %, b) Т11 = 40,2 %
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
89
Т12 – Happiness (P30).
The parameter displayes position of test result on I-E diagram. Low level of energy
consumption and high level of the information content of the exchange mean high level of T12. If
energy consumption increases and PPS (mood) decreases than T12 becomes smaller.
a) b)
Fig. 4.12 Happiness: a) Т12 = 43,3 %, b) Т12 = 90,9 %
Note:
The set of parameters T1 – T12 is selected for capturing of the maximum information content
for human head micromotion. At the same time the name of each Ti parameter can characterize
different physiological characteristics, depending on the application of the vibraimage system. The
primary characteristic for each parameter is not his name, the name can be considered secondary, but
only math formula (equation) for psychophysiological parameter calculation is primary.
Mathematical formulas, on which a calculation of parameters T1 – T12 are shown in the description
of the program of statistical processing of the measurement results (VibraStat).
Note:
1. Every from T1-T12 psychophysiological parameters measured by vibraimage system
are specified to range 0 – 1 (0 – 100) % using fixed coefficients experimentally selected.
2. Mathematical formula by which measured psychophysiological parameter is
determined is primary, and a code name (for example, Agression) is secondary. Psychophysiological
meaning of each parameter T1 – T12 may be varied depending on the experimental conditions.
3. The set of measured parameters T1 – T12 determines the total psychophysiological
(psychosomatic, functional) status of a person based on the integral coefficient K.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
90
Note:
This description is valid for the parameters to the default settings of the system and perform
basic rules for getting vibraimage:
uniformity and stability of the lighting;
use of low-noise television cameras;
frontal location of the object in front of the camera;
maximum "inscribing" the subject's face in the monitor;
mechanical stability of video camera.
4.1.1 "M" mode of information panel
In a "M" mode an information column (fig. 4.13) allows to control average for the period
parameters value of psycho-emotional person conditions and their deviation from the established
norm. The basic applicability of the given mode is use of vibraimage system for medical diagnostics
and psychological researches. Start of the beginning of information accumulation is made by a choice
of item "Measurement" of the menu "Action" or pressing of the toolbar button . Value of the
averaging period is set in seconds in a field "Duration". After start of an accumulation and averaging
mode in the top of an information column there is a running line "Progress", displaying a course of
data accumulation process.
Fig. 4.13. "Measure" mode start
с
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
91
After gathering information in the information column in the "M"mode for all vibraimage
parameters (A1 – A4, F1 – F9, S1 – S7, P1 – P4) and all the parameters that characterize the psycho-
emotional state of a person (T1 – T12), displays the following information :
V – The value of the parameter average for the set period;
S – root-mean-square deviation of parameter;
Vi – The variability of the parameter over a specified period;
cMin – The minimal value of parameter for the period;
cMax – The maximal value of parameter for the period;
NMin – The minimal value of parameter for a normal condition of the
person;
NMax – The maximal value of parameter for a normal condition of the
person.
Note, after ending of the information accumulation some lines of an information panel can be
allocated by color:
– parameters, which values less than the set limits are allocated.
– parameters, which values more than the set limits are allocated.
Statistically set norms (corresponding to the normal state of man) for supervised psycho-
emotional parameters Aggression, Stress, Tension/Anxiety, Suspect, Balance, Charm, Energy, Self
regulation, Inhibition, Neuroticism, Depression, Happiness are shown in Figure 4.14 in columns and
NMin NMax. Note, that each parameter has its own range of normal values and deviations.
Set of the T1 – T12 parameters is selected so that with the maximum information content to
record all micromovements of a human head. Thus, the name of each Ti parameter can characterize
different psychophysiological characteristics depending on use of any VibraImages programs.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
92
Fig. 4.14. Information panel in "M" mode.
4.1.2 Psychophysiological state analysis results
Note, that the analysis results are automatically saved in the database folder in the form of
following files:
Data_time_M.xlsx – report file with the base results of psychophysiological state
analysis of a person for the specified period.
Data_time_histH.png – frequence histogram
Data_time_histT.png – an analysis of changes in the human psycho - emotional state
at the time of testing
Data_time_histH.xml – system settings and change the basic parameters of the
psycho - emotional state of a person. Note, The parameters T1 – T12 defined in the M
mode, may be processed in VibraStat program
Note, that the base results of psychophysiological research are given in Data_time_M.xlsx
file (see Fig. 4.15).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
93
Fig. 4.15. Base results of the human psycphysiological state analysis
The parts of base results could be looked more detail by additional tables and pictures.
After gathering the information will be available the results of "Frequency Analysis" and the
analysis of changes in the psycho - emotional state of a person. To do this, the appropriate sheets (see
Fig. 4.16) must be opened in the main image window.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
94
Fig. 4.16. Frequence histogram in sheet "Н"
In a window with the frequency histogram will be showed the graph of amplitude histogram
(the graph is painted by red color), the histogram of frequency is painted by green color.
Each histogram is characterized by the following parameters:
М – the center of weights of frequency distribution (average value of microvibrations
frequency);
S – root-mean-square deviation of frequency distribution;
D – a dispersion of frequency distribution.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
95
Fig. 4.17. Information-energy diagram of the PPS
The results of the analysis of the information-energy state are showed in "T" sheet. The point
on the graph shows the current psycho (information) – energy state of a person. The Y axis is
displayed in % mental state (information comfort of his mental state). The X axis in kcal / min
displays how much energy a person spends on controling its psycho - emotional state.
Note, if you open the "T" sheet and start the process of gathering information , in the
open window you can see how the human condition changed during the experiment.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
96
а) changing around the average value b) stable condition, indicating a high degree
of self-control person
Fig. 4.18 (a, b). Change person psycho-energy conditions for the chosen period
Change of psychoenergy state of the person during a controlled time frame is visually reflected
in a graphics (fig. 4.18). Only the person who is in weakened, or on the contrary in a status of high
concentration (fig. 4.18-b), can be in the fixed psychoenergy state during such insignificant time, as
1 minute. The majority of people is made by noticeable oscillations of psychoenergy state, even for
short periods, depending on the thoughts (fig. 4.18-a) and under the influence of an environmental
situation.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
97
4.2 Macro mode. The suspicious people detection in crowd
VibraImage system allows controlling macromovements (macrovibrations) as microvibration.
Macromovements analysis uses the same principles as the control of micro-movements, at the same
time it allows to monitor the status of the people in the crowd. If micromovements of human head
can not be seen without a technical system, it was well known that movements and psychomotorics
reflect emotional state of person since such behavioral reactions are well observed by psychologists
and profilers. However, visual inspection of the movements is really subjectivity, at the time, as the
vibraimage system macromovements control completely objective and is determined by the
calculation formulas and the selected system configuration. The optimal camera location and the
choice of checking place are determined with considering the lens parameters, the distance from the
camera to the object and the amplitude of motion of the object.
Macro mode gives lowest accuracy in the measurement of psychophysiological parameters
relative to Mix and Micro modes. With correct vibraimage settings is possible to achive minimal error
rates as (10 % < FRR < 20 %) in the Macro mode.
When choosing the location of the TV camera relative to the envestigated group of people is need to
use the following recommendations:
The maximum display of human on the frame is preferable, and the camera should not be
unduly moved from the envestigated group.
People in the envestigated group must be approximately on the same distance from the
television camera.
In the analysis of the emotional state should use an equivalent comparison principle, the
correct is a comparison of people making near the same motion, for example, feed the ticket compared
with the person submitting the ticket, the person transposing luggage compare with a person
committing the same act, etc.
Note, that in order to improve the accuracy of the human state measurement, reccomends to
control its movement in maximum details, therefore, observe the minimum number of people in the
frame. Question of the measurement accuracy for the psychophysiological state should be decided
separately for every controlled object. In this case, for more accuracy it is recommended to use
personal control in MICRO mode for suspicious people detection in the high important places.
4.2.1 "Macro" mode parameters
Load basic MACRO modes parameters of operation is carried out using a submenu "Settings"
– "Defaults". When one of the basic modes of operation (micro, macro or lie detection) select and
load its default settings, the system automatically displays only the necessary window mode
(Fig. 4.19). To work in the "Macro" are necessary images window, "Suspect" level window, which
will display the value of danger level, and "Image capture" window detected potentially dangerous
people photos.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
98
Fig. 4.19. Macro mode windows
Figures 4.20, 4.21 shows a comparison of the basic settings are set automatically when you
select Micro and Macro mode :
When micromotion control system also monitors the status of the person at the three
different accumulation times (from 0.1 to 20 seconds), characterized by the number of frames N = 2,
10, 100. Recommended accumulation amount frames in macro mode comprise N = 5, 10 and 15
frames that the input frequency 15 f/s, corresponding 0,3-0,6-1,0 second. Comparison of the number
of movements made by a person in a given time, gives a clear picture of the psycho-emotional state
of a person. If a person is excited or aggressive state, it makes a lot of movement than those who are
at rest, and it stands out vibraimage color coloring compared to other people.
"Palette threshold" is set at the control macromovements above (L = 150) than in
the control micromotion (L = 2).
Frequency of "base processing"under the control macromovements set substantially
higher than in the control micro-movements, to the 15 f/s instead of 5. This is due to the fact that
when micromovements no point in increasing the sampling rate, as TV system noise does not allow
stable fixing micro-movements with a higher frequency. Another thing macromovements control -
movement of the hands, feet or body when walking, turning or other fixed macromovements
confident enough television camera, and significantly higher than the noise level.
In macromovements analysis mode to increase the computing capacity of a PC, the
calculations are disabled several parameters and the "Disable " information column "S".
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
99
Fig. 4.20. Default setting for Micro mode Fig. 4.21. Default setting for Macro mode
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
100
Especially for setting display modes when using the Macro mode in the information column
"S" introduced a number of parameters:
Macro section:
Маcro mode – If "Macro mode = Yes" than danger level calculation is made on the
basis of values of parameters Р13, Р14, Р15 (the description of parameters is see lower). In
"Micro" mode danger level calculation is made on the basis of the analysis of values of
aggression (Р7), stress (Р6) and tension parameters.
Level L – sets a palette threshold at danger level calculation. Vibraimage points which
brightness less than the specified threshold, are considered «black"and are not used at
calculation of a danger level. The vibraimage point is considered active, if its brightness more
than the set threshold"Level L". Parameter Р15 defines the relation between the area of
«active"vibraimage points to the area of all frame. Parameter Р13 characterizes shift of the
histogram to the right in area of high frequencies. So that parameter defines primary color of
"active"points of vibraimage.
Level S – defining the area of "active" vibraimage points. If the area of points (in %),
which value of brightness is more than value "Level L", is less than value "Level S", than
danger level value displayed in status window equally 0. So, if in the frame it is not a lot of
"active" points, the level of danger is not calculated.Parameter Р14 defines in % excess of
the area of active vibraimage points above the set threshold of "active" point"Level S". So,
if the number of "active" points grows, value of this parameter too grows also a level of danger
increase.
Aura mode – automatic cut output vibration aura when working in macro mode.
Macro mode + – when mode is switch, the danger level is considered for each
individual person in the frame. In off mode - the danger level is averaged over the entire frame.
"Macro mode+" = NO recommended when working of face detection algorithms is not
effective in this particular case.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
101
Fig. 4.22. Macro mode basic settings.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
102
"Alerts" section:
"Critical level" – sets a threshold of "danger level" at which excess the person is
considered "dangerous"
"Customer level" – sets a threshold of "danger level" below which the person is
considered "dangerous"
"Auto capture image (s)" – If set «non zero"value, then the image of "dangerous"
object at his detection will be automatically save in an external file. The chosen value of the
given parameter determines in seconds the period of saving the pictures in a file.
Simultaneously the image "dangerous"will be displayed in "Image capture" windows.
"Show N image" – If set value N distinct from 0 in "Image capture" window will
be displayed at once N images of the "dangerous" people which have been found out for the
specified interval "Auto capture image (s)". If set value N = 1 – that for the specified interval
in "Image capture" will be displayed only one image, and we can pass other "dangerous"
person!
"Auto capture image (s)" – value of this parameter (other than 0) specifies the
number of seconds between saving images to a file and display them in "Image
capture"window.
"Area threshold %" and "Area level %" – these settings are recommended only for
experienced program users. Area and significance (level) coefficient factor are given in % and
is introduced to take into account the factor of small area of moving objects relative to the
area of the whole frame when calculating the danger level.
4.2.2 Face detection mode
Switching on the "Face detection" is made in the same section of the "S" information panel
(see Fig. 4.23).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
103
Рис 4.23. Macro mode. Face detection is switch on
The parameter "Detection quality" defines quality of persons face capture. 1 – capture only
one large person in the frame (loading of the processor is minimal), 4 - search of all face (even small)
persons in the frame (loading of the processor is maximal).
Parameter "Scale 1:X" sets picture compression ratio before process of search of persons. By
default, value 2.0, i.e. video of a format 640 х 480 will be transformed by the program to a format
320 х 240. Compression of a format is necessary for reduction of loading of the central processor in
case of simultaneous increase in speed of the main processing (base processing). In case of value 0
compression isn't made. The lower the compression, the more CPU usage. The greater the
compression, the lower face recognition algorithm works.
Parameters "Mines size" and "Max size" set the sizes of rectangular (in pixels) for persons
face searching. The given parameter is necessary for set depending on concrete medium-sized people
on the computer screen.
The parameter "Config" is intended for loading new algorithms of persons search. At
installation of Vibraimage program on your computer will be created the subdirectory
"…\VibraImage10\Ocv\" in which files of various algorithms of persons search settle down. For
loading new algorithm, it is necessary to execute the following actions:
1. In "File" menu select item "Open". Then open folder \VibraImage10\Ocv\ and choose
new algorithm for calculation.
2. In line "Config" appear path to selected file.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
104
Note, that each algorithm at work require different amounts of computer resources and
implementing different quality capture individuals. When choosing the algorithm is recommended
not to exceed the CPU utilization of more than 70 %. By default, when you install the system
VibraImage very little resource-loaded algorithm ocv_face.xml. For fast computers recommended
load frontalface_default.xml algorithm. But, note, the choice of the algorithm and the quality of the
capture of persons recommended when setting up the system after it is installed in a particular
location.
If parameter "Draw" = No – not draw rectangle around face. If "Draw" = Yes – draw
rectangle around "more danger" single person, "Draw" = All – draw rectangle for all person in frame:
For non-danger person rectangle draw green color, but if person suspect level more than
«Critical level», than rectangle draw red color (see Fig. 4.24).
If a potentially "dangerous" man except the red outline appears around the head and a red
outline around the body, this person requires more attention from the security services,
because the system repeatedly fix it increased the suspect level.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
105
Fig.4.24. Attention, "Critical level" = 55 is exceeded
4.2.3 First start and settings selection for Macro mode
Before working in the "macro"mode is recommended to (or control) the following settings in
VibraImage system:
1. In the System menu "Settings" – "Defaults"switch on "Macro" mode and load the default
settings or to the "File" menu to load own "Macro" mode settings from an external file
("Load Settings")
2. In "DB" information panel:
Set the path to the database directory, which will be saved video files and results files.
Choose "Selected record" or create "New record".
3. In “S” information panel in "Face detection" section:
If you need to load a new algorithm to search persons.
Set the minimum and maximum dimensions of the frame to search for persons.
Set the required quality of face recognition.
Set the desired value scale compression of images
"Draw" parameter set to "Yes" or "All".
4. In "S" information panel in "Alerts" section:
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
106
Set the value of "Critical level", which corresponds to the current mode of
observation.
Switch on the sound notification of the dangerous man by setting "Sound
(Suspect)" = Yes.
Set parameter "Auto capture image (s)" = 1 sec.
Set parameter "Show N images" = 3 to display both 3 photos of potentially dangerous
people.
5. In "S" information panel in section "AVG Filter" sets parameter «Suspicious» = 5 – 10.
6. In "S" information panel in section "Capture" sets parameters values:
In fields "Max length(s)"sets maximum length (in seconds) of recorded video file.
The recommended value is 300 seconds.
In the "Purge old files (Mb)" field to specify the amount of free disk space, at which
the system will record new video files over the old ones. Recommended value
20000 Mb.
7. If necessary, select the item «Save settings as..."in "File" menu and save the current system
settings in an external XML file.
8. If you want to save the AVI file than using "AVI: Start Capture" item of "File" menu or
using the appropriate control panel button.
9. Start working in Macro mode.
Attention!!!, if you are changing system settings when working in the "Macro" mode, then
you need to constantly monitor the following settings:
1. After start of Vibraimage program and person vibraimage displaying on the screen
loading of the computer central processor power must be less than 60 %.
2. Speed of input frame processing. Speed of "fast processing" should be not less than
25 frame per second at resolution not less 640 х 480 pixels. Speed of "base processing"
should be not less than 14 – 15 f/s.
If you change the "macro" mode settings and specified speed is not respected, it is necessary
to set other parameters that require less computer resources.
Note, when a detailed system configuration at a particular place of its installation may require
advanced settings "Area threshold", "Area level", "Level S" and "Stab. X, Y".
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
107
4.3 Mix mode. The suspicious people detection with high accuracy
Mix Mode is similar to both Micro and Macro. Goal of Mix is to take accuracy from Micro
and applicability from Macro. Face detection must be enabled in this mode. Vibraimage analysis in
Mix mode occurs inside the contour of faces detected by face recognition algorithms. For more
information on the settings for the face detection mode, see section 4.2.2. In the information panel in
Mode S in the face detection section, the config option is shown twice. At first program is processing
video by the first face detection algorithm. If it does not find the face, then the program starts the
second face detection algorithm placed in the down line config and selected for a facial detection. In
default setting the first face detection algorithm is selected ocv_face.xml and the second face
detection algorithm is selected profileface.xml. Suspicious person is immideatly indicated on the right
part of program window. Advanced users can do changes in default settings.
Mix mode gives accuracy in the measurement of psychophysiological parameters as in Micro
mode but for many people as in Macro mode. 10 print with psychophysiological parameters is shown
for person with maximum level of suspicious. With correct vibraimage settings is possible to achive
minimal error rates as (8 % < FRR < 15 %) in the Mix mode.
Requirements to video in Mix mode:
People should be in a frame on approximately one place not less than 5 seconds. Better if
everybody in line or in crowd goes through the checking place for this purpose.
Camera must be focused on the place where people stay the longest time (for example in
line on the first person).
In mix mode data are processed for all detected people in a frame.
4.3.1 Mix mode parameters
Load basic Mix modes parameters of operation is carried out using a submenu "Settings" –
"Defaults". The system automatically displays only the necessary window mode (Fig. 4.25). Images
window, Histograms window, information panel, "Suspect" level window, which will display the
value of danger level, and "Image capture" window detected potentially dangerous people photos
are necessary in the "Mix" mode. With option "Print Suspect" you can set look of the captured image
(see fig. 3.60 p. 3.6.6)
Each detected person has his own contour with real-time calculated micro mode parameters
(Aggresive, Stress etc.), Vibra aura and current suspect level under the contour (see fig. 4.25). The
most suspicious person in the frame is highlited by dotted line.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
108
Fig. 4.25. Mix mode windows
Figures 4.26, 4.27 shows a comparison of the basic settings are set automatically when you
select Mix and Macro mode:
Frequency of "Base processing" under the control macromovements set higher than
in the control micro-movements, to the 10 f/s instead of 5. This is due to the fact that when
micromovements no point in increasing the sampling rate, as TV system noise does not allow stable
fixing micro-movements with a higher frequency. Another thing macromovements control –
movement of the hands, feet or body when walking, turning or other fixed macromovements
confident enough television camera, and significantly higher than the noise level.
"Downrate" 3 instead of 0
Micromotion control system also monitors the status of the person at the three different
accumulation times (from 0.1 to 20 seconds), characterized by the number of frames N = 2, 10, 100.
Recommended accumulation amount frames in mix mode set N = 2, 10 and 40 frames that the input
frequency 10 f/s, corresponding 0,2 –1 – 4 seconds. Comparison of the number of movements made
by a person in a given time, gives a clear picture of the psycho-emotional state of a person. If a person
has exciting or aggressive state, he makes a lot of movements in comparison with those who are at
rest, and his vibraimage color stands out from other people.
"Palette threshold" is set as in the control micromotion (L = 2)
In Mix mode to increase the computing capacity of a PC, the calculations of several
parameters are disabled and the "Disable" information column "S".
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
109
Fig. 4.26. Default setting for Mix mode Fig. 4.27. Default setting for Macro mode
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
110
Other parameters as in Macro mode (see p. 4.2.1)
"Auto capture image (s)"– value of this parameter (other than 0) specifies the number
of seconds between saving images to a file and display them in "Image capture" window.
4.3.2 First start and settings selection for Mix mode
Before working in the "mix"mode is recommended to (or control) the following settings in
VibraImage system:
1. In the System menu "Settings" – "Defaults"switch on "Mix"mode and load the default
settings or to the "File"menu to load own "Mix" mode settings from an external file ("Load
Settings ")
2. In "DB"information panel:
Set the path to the database directory, which will be saved video files and results files.
Choose "Selected record" or create "New record".
3. In "S" information panel in "Face detection"section:
If you need to load a new algorithm to search persons.
Set the minimum and maximum dimensions of the frame to search for persons.
Set the required quality of face recognition.
Set the desired value scale compression of images
"Draw" parameter set to "Yes" or "All".
4. In "S" information panel in "Alerts"section:
Set the value of "Critical level", which corresponds to the current mode of
observation.
Set the value of "Customer level", which corresponds to the lower level of danger.
Switch on the sound notification of the dangerous man by setting "Sound (Suspect)"=
Yes.
Set parameter "Auto capture image (s)" = 1 sec.
Set parameter "Show N images" = 3 to display both 3 photos of potentially dangerous
people.
5. In "S"information panel in section "AVG Filter"set parameter "Suspicious" = 0
6. In "S"information panel in section "Capture"set parameters values:
In fields "Max length(s)"set maximum length (in seconds) of recorded video file.
The recommended value is 300 seconds.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
111
In the "Purge old files (Mb)" field to specify the amount of free disk space, at which
the system will record new video files over the old ones. Recommended value
20000 Mb.
7. If necessary, select the item "Save settings as..." in "File" menu and save the current
system settings in an external XML file.
8. If you want to save the AVI file than using "AVI: Start Capture" item of "File" menu or
using the appropriate control panel button.
9. Start working in Mix mode.
Attention!!!, if you are changing system settings when working in the "Mix" mode, then you
need to constantly monitor the following settings:
After start of Vibraimage program and person vibraimage displaying on the screen loading of
the computer central processor power must be less than 60 %.
Note, the default processing of Suspect level is going only by Aggression processing. The
settings for including Stress and Tension for processing are placed in S/Filters/State levels.
Note, the sensitivity of suspect capturing in Mix default settings mostly depends on N level.
Lower sensitivity gives higher then default (40) N level. Higher sensitivity of suspect capturing gives
lower N level.
Note, PRO program processor power in Mix mode depends on a number of persons in
processing video, more processed people in frame requests higher power from processor. It is
necessary to check current processor power not exceed 80 % and Base processing rate about 10 f/s.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
112
4.4 LD mode. Lie detection
The VibraImage program of psychophysiological lie detection allows revealing verbal and
nonverbal lie in the automatic, automated and manual modes. The program allows fixing and
comparing psycho physiological parameters of the person during the various moments of time at use
of various modern techniques of interrogation. All means existing now lie detector register changes
various psycho physiological parameters of the person, thus it is considered, and that essential change
psycho physiological parameters is observed when the person worries, is excited and speaks a lie. In
a still condition of person his psycho physiological parameters and emotions vary less considerably
in time, hence, having compared a known still condition with the answer interesting us it is possible
to define, when the person speaks the truth and when speaks lie.
The program allows to fix and compare psycho physiological parameters of the person during
the various moments of time. VibraImage system makes measurement and the analysis in time more
than 40 independent parameters describing an emotional condition of the person. The standard
method of definition of lie is based on an estimation of emotional reaction of the person on the put
question.
The standard method of lie detection is based on an estimation of emotional reaction of the
person on the put question. In an operating time the operator marks on graph CQ questions (Control
Question), RQ questions (Relevant Question) and GQ questions (General Question), pressing on the
same buttons , , on the toolbar at time of the given questions. After the ending of the
test the operator can check results of work in a special created file.
4.4.1 Before starting LD mode
For correct lie detection by Vibraimage system is recommended to take into account the
following factors and conditions:
1. The image of the person should be high quality, the maximal facial size preferable and face
position must be in the center of the screen. For camera horizontal resolution across 640 pixels
the person face should be not less than 200 pixels.
2. The object (person) should be well and stable illuminated also (black-and-white- preferable,
or color) the image of the person should be precise and contrast. As lie detection depends on
detection of the microvibrations and the object micromovements fixed in reflected from object
light, therefore poor light exposure of object can increase error rates.
Natural illumination of object can be used if speed of natural light changes does not exceed
1 lux/sec. Illumination of object by fluorescent lamps with illumination in the range 400 –
600 Lux in object plane is preferable.
3. In a video camera options, it is necessary to switch on a mode of fluorescent lamps noise
suppression (flicker mode 50 Hz and 60 Hz).
4. In camera options it is recommended to use black-and-white image mode.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
113
5. Presence of the other people, taking place in the frame near to the researched object, can
influence and increase error rates of lie detection.
6. The video camera used for surveillance, and/or object on which the camera is fixed, should be
motionless and have no vibrations. The vibration or movement of camera can increase error
rates of lie detection
7. Speed of input frame from the camera should be not less than 25 – 30 frame per second at
resolution not less 640 х 480 pixels.
8. After start of Vibraimage program and person vibraimage displaying on the screen loading of
the computer central processor power must be less than 60 %.
9. The set of a microphone is recommended to use external, not built-in in the camera or
notebook.
10. At work with videofiles it is recommended to use files in length of 5 – 10 minutes and for
exact lie diagnostics it is recommended to analyze the same file repeatedly some times.
11. Press button before next lie detection of the same file. button works as reset and
stabilized detection results. Double click on this button fixed graphs time equal to the video
file period.
Note
At repeated viewing the same videofile the deviation in repeated values the same parameters
up to 5 % is acceptable because live video is the same as live object error rate less than 5 % is normal.
For stable work in a "Lie detector" mode is recommended use personal computer CoreDuo2 3 GHz
(not less than 4Gb RAM) or more powerful. At such computer speed of input frame from the camera
should be equal speed of fast parameters processing FPS_in = FPS_fast > 25 – 30 frame/s.
4.4.2 Switch on LD mode
Load basic LD modes parameters of operation is carried out using a submenu "Settings" –
"Defaults". When one of the basic modes of operation (micro, macro or lie detection) select and load
its default settings, the system automatically displays only the necessary window mode (Fig. 4.28).
To work in the "LD" mode are necessary images window, "QT" image quality window, "LDr" lie
level window, "Graph" window with changing main parameter, and "LD question" window for
show questionnaires question.
Window "Quality Test" (QT) indicates the time in %, for which the image quality of 100 %.
When the quality test indicates 92 % means that only 92 % of the testing time have no errors, and the
57 % of test time the image quality contained 1, 2 or 3 errors.
Note, before the start of the LD detection should ensure that the program processed the image
of a human without errors and work is allowable only at quality more than 80 %.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
114
Fig. 4.28. "LD" mode settings load
Next, using the toolbar button , or via the submenu "Presets" menu "View" (see Fig. 4.29)
need to switch on the LD mode image display.
Fig. 4.29. System ready to LD mode
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
115
Attention, at work in a LD mode is recommended to supervise under graphs of change in time
following psycho physiological parameters describing all types of impellent activity: А1 fast, F3, F6,
S2, P2, P5 and Р20.
A1 (fast) – shows maximum fast reaction of person for question or situation, so it changes
before any other VI parameters, but goes down also immediately as it changed. This parameters shows
macro movement and sometimes used for deleting artifacts from the lie detection process.
F3 – shows general mental energy level of examinee, in default settings this parameter
calculates for time period of 20 seconds, so it is slowly changing parameter reflects psycho
physiological state. High level of this parameter indicates high level of exciting, aggression or activity
so it could be correlated with lie.
F6 – shows inhibition of person and also correlated with respiratory tracing or breathing
activity, because it is physiology linked with inhibition process.
S2 – shows asymmetrical of movements in middle time (2 sec) period, so it includes left/right
hemisphere activity components and it high changes usually indicates lie.
P2 – shows Mean-Square-Deviation (MSD) of frequency histogram and low meaning of this
parameter usually indicates normal state, so high meaning of this parameter could be correlated with
lie.
P5 – indicates Lie level auto calculated for selected parameters, in Default settings for Lie
indication need to have significant changes at least in 8 vibraimage parameters, typically in Lie
detection system registers significant changes in 12 or more parameters, given in Lie Report.
P20 – Quantity indicator of a degree of change psycho physiological parameters in view of
various factors of the importance of measured parameters since the part of parameters is accelerated,
and others are slowed down during one reaction. Parameter Р20 is defined at the moment of P5
maximum and display in "LDr" window.
When working with graphics, special attention should be paid to signal changes in the graph
of parameter P5 (lie), which define the most "suspicious"moments in human behavior. Each question
and answer (preferably separated by a time interval of not less than 10 seconds) is characterized by a
level change phycho-physiological parameters tested person. This level is characterized by two
integral indicators – the level P5 (see Fig 4.59.) and parameter P20 in the window "LDr", which
provides a quantitative assessment of human responses to the question. The higher this parameter, the
more likely lies in the response.
4.4.3 LD working mode
Select the method of of the beginning lie calculating [LD mode] is made in the "ST"
information column in field "LD mode" (see Fig. 4.30).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
116
Fig. 4.30. LD mode settings.
The system uses the following ways to start the lie level calculation:
1. Audio – lie level calculation is performed when the input audio signal exceeds the threshold,
and stops when the audio signal level becomes less than the set threshold. On graph at the start
of data collection displays vertical green line, the time of completion – a vertical red line.
This mode is recommended as the primary when working with a lie detector.
2. Manual – the accumulation of the preliminary information is available at the "Base periods".
Calculation of a lie level is made only after selecting the "Start LD block" item in menu
"Actions" (or corresponding toolbar item). To complete the calculation interval of lie
detection, you must repress the same button or choose the same menu item. Time of lie start
calculation is marked by a vertical green line, calculate the end – red.
Lie detection in the manual mode are usually used, if the quality of live or recorded sound is
unsatisfactory and can not be on the level of sound to separate the questions and answers of
the test person from outside noise.
3. Auto – calculation lie level is made constant, the current values of the parameters are
compared with the values accumulated in the preceding period.
When operating in lie detecting mode in an "S" information column (see Fig. 4.27) is set the
interval "Base period" (in seconds) during which the system collects data about the object under
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
117
study, accumulates the information to determine the maximum and minimum current values
parameters to then at "lie detection" during the "Stat periods" define "abnormal" change the values
of the individual parameters of the object. If the value of the parameter during the "Stat period"
exceeds the set limit, then it parameter is taken into account when lie level calculating with a certain
coefficient (weight (Rate) of this parameter).
The base case "Base period" immediately precedes the moment of the beginning of the
analysis lies. But the system provides the ability to collect initial information about the object at any
time. When you select a item "Compare" = Capture will be made beginning start the sampling
interval at an arbitrary time. To complete the collection interval, you must change the settings
"Compare "value.
Now when you lie detection analysis the state of the object will be compared with the
information stored in previous time in one of two ways:
"Compare" = Off – at the lie analysis, as a test, using the interval "Base period"
immediately before the start of lie detection.
"Compare" = On – in the lie analysis, as test, the interval "Capture period", which was
prepared preliminary.
4.4.4 Additional settings in "S" information panel
1. For stable work in a "Lie detection" mode in section "Filters" of the "S" information panel
it is necessary to set parameter "FPS filter" = YES. The parameter "FPS filter" provides stability
of input video frame stream frequency due to resources of a computer. If the parameter "FPS filter"
= No, then parameter «Downrate" in "S" information panel sets factor of division of input frame
frequency FPS_in for all processing mode (base and fast). If the parameter "FPS filter" = Yes, then
parameter "Downrate" sets factor of division of input frame frequency only for base processing
mode. If "Downrate" = 0, then division factor calculated by system automatically. If input video
frame stream frequency not stability, then additional parameter "Stream errors" in "VI" information
panel displayed quantity of entrance frequency "failures".
2. Additional parameter "Audio sens. s." in an "S" information column sets in seconds, how
many after the person answer ending still to continue to analyze his condition
3. The parameter "Lie threshold" in an "S" information column sets in % a threshold for the
indicator of a lie level in view of all designed parameters and their "weight". At excess settlement
value of this threshold "lie level" is registered and displayed.
4. Each person differently reacts to lie by virtue of the psycho physiological features. The part
of people when lie, "worries" also their reaction (value of parameter Р5-lie) on the "important"
questions (RQ questions) exceeds reaction to control questions (CQ questions), and the system
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
118
registers a condition of lie (DI). For such people parameter "Opposite mode" = NO (it is a mode by
default). And the part of people – on the contrary, internally "is clamped (strains)" and their reaction
(value of parameter Р5-lie) on the "important" questions (RQ questions) less reactions to control
questions (CQ questions), and the system does not register a condition of lie (NDI). For such cases
for increase of reliability of lie detection results the parameter "Opposite mode" = Yes (it is a mode
is recommended for experienced users).
Note, VibraImage system requests correct adjustment of input audio signal (procedure of
adjustment see above). The moment when the person starts to speak, is used by system for the analysis
start of the data in Audio mode. Vibraimage parameters during speaking (Stat period) are compared
to the data received earlier (Base period), for example, when the person was silent or neutral answer
questions.
Therefore, it is necessary to adjust preliminary an "Audio level" so that the surrounding level
of a sound was below threshold, and the level of a sound at the task of a question and reception of the
answer was higher threshold.
Fig. 4.31. Audio level adjusting
To adjust sound level is necessary in an "VI" information column to measure the sound level
(fig. 4.31) for the two states: "the silence in the room" and "the sound of the human voice to the
camera". Then in the settings of "lie detection" in the "S" information column set the parameter
"Audio level" (fig. 4.31) so that its value was in the middle position between the minimum value of
the input signal that corresponds to the silence in the room, and a maximum value, which corresponds
to the sound voice man facing the camera.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
119
Values of system options recommended (by default) for work in a lie detection mode:
Stat period = 10 s
Base period = 5 s
Lie Threshold = 0 %
Opposite mode = No
Audio sens = 2 s
N = 100
4.4.5 Settings in «LD"information panel.
If you have enough experience works with the lie detector, you can manually configure the
numerical values of the parameters A1 to P29, opening the appropriate «LD"information panel (see
Fig. 4.32).
Fig. 4.32. LD mode of information panel
For each parameters displays the following numerical values:
V – Current parameter value;
cMin – The minimal value of parameter during the "Stat" period;
cMax – The maximal value of parameter during the "Stat" period;
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
120
bMin – The average basic minimal value of parameter for a normal condition of
the person during "Base" period;
bMax – The average basic maximal value of parameter for a normal condition of
the person during "Base" period;
For each parameters set following numerical values, which using in Lie detector calculation:
Calculate Yes – this parameter using in LD level calculation, No- not using
R1V "Weight" of parameter (Rate1) if its current value became more than the
set base maximum bMax OR became less than the set base minimum
bMin. Use in Р5 parameter calculation.
R2V "Weight" of parameter (Rate2) if its current value became more than the
set base maximum bMax AND became less than the set base minimum
bMin. Use in Р5 parameter calculation.
R1C "Weight" of parameter (Rate1) if its current value became more than the
set base maximum bMax OR became less than the set base minimum
bMin. Use in Р20 parameter calculation.
R2C "Weight" of parameter (Rate2) if its current value became more than the
set base maximum bMax AND became less than the set base minimum
bMin. Use in Р20 parameter calculation.
Level In % determines on how many value of parameter should exceed the
set limits that the system "considered"this change.
The following are examples which illustrate the principle of collecting information. Fig. 4.33
has no difference in the "threshold" values of S2 in intervals "Stat period" and "Base period".
In fig. 4.34 during the interval of definition lies (Stat period) value S2 has exceeded the maximum
threshold.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
121
Fig. 4.33. S2 parameter value is within the limit
Fig. 4.34. One of the parameters was significantly higher than both the established limit
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
122
4.4.6 Backster’s test
The basis of lie detection is a technical comparison of the principle of psycho-physiological
reactions responses zones (introduced Clive Backster), it is quite easy to understand and allows each
person to accurately determine the truth and lie even with minimal experience in working with
VibraImage system.
Principals of comparative testing and averaging for responses of question-answer zones,
coined in the 60th years of XX century by Cleve Backster
(http://www.backster.net/images/accuracy.pdf), gave requested high accuracy for
psychophysiological detection of deception and have done lie detector the reliable instrument in
expert hands. The comparative zones are based on the fixed structure of question-answer testing,
including general, comparative and relevant questions in one test. So fixed test structure allows
combine analyzing of response to several similar questions, so it is possible to calculate average
response to several control questions and separately calculates average response to several relevant
questions. This testing structure gives more accuracy for any measurement, so it is acceptable also
for lie detection, too. Standard lie detection test structure includes 9 – 14 questions, one of these
questions relevant (most important) is presented by several times (during one test), because was
proved that during one test is correct to present the only one relevant question. Several relevant
questions in one test give more errors, because examinee could concentrate only on one question
during the test.
Let’s consider the test structure on the simple actual test sample: You are interesting where
your partner was at night, when he tells that was working in office. In this case the question "Really,
were you in the office last night?" is relevant question and the main important question of this test.
All test must include several questions for replying one meaning answers as Yes or No, like the
suggested sample:
1. Did you have breakfast yesterday, as usual?
2. Was the cold weather on the morning street?
3. Did you tell lie to your friends?
4. Did you work in office this night?
5. Let’s go to cinema this weekend?
6. Did you ever tell lie to me or my family?
7. Really you were in office this night?
8. Did you take your purse from home at this morning?
9. Did you steal something before?
10. Is it true, that you were working this night?
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
123
General (blue) questions (GQ) have diverted meaning and have not influence to calculation
result, but they are necessary for reducing concentration attention of examinee on the relevant
questions. Response to the control (green) question (CQ) is very important to the test calculation,
control question usually asked about past criminals, which are happened in everybody life. The verbal
answer on control question is not so important (Yes or No), more important is psychophysiological
response corresponding to this reply. If quantitative average response to control questions is more
than analogical quantitative average response to the relevant (red) questions (RQ) that means person
tells true. If quantitative average response to relevant questions (RQ) is more than analogical
quantitative average response to the control questions (CQ), that means person tells lie.
4.4.7 Lie detector with questionnaires
Program VibraImage has a special type series of thematic questionnaires intended for human
psychophysiological person testing, such as passing an interview before obtaining a credit.
You can select an existing questionnaire suitable for you ("Loyalty", "Alcohol", "credit",
"bribe", "Family" and others.) or create your own. An example of the questionnaire is shown in
Fig. 4.35.
The aim of the survey "Loyalty" is the definition of human loyalty basic principles of security
of modern society, and combating terrorism. The questionnaire includes graphics (incentives) that
increase psychophysiological effect on the test.
The aim of the survey "Credit" when issuing a credit is the lack of definition lies in the
intention of the applicant for the loan and detection of fraud in obtaining credit.
The aim of the survey "Bribe" is to determine the reliability of the test person answers that
he did not take bribes at the current position.
The survey "Family" is to detect lies with whether or not he had the answer to the question
of the subject the previous evening, at work, or located elsewhere.
Questionnaire "Insider" is intended to test, to hire personnel, the possibility of selling
company secrets to competitors.
The questionnaire R_Test allows rank (to determine the significance of) the test
psychophysiological response to questions.
Questionnaire "Alco" is intended to identify those who are likely to use alcohol.
The questionnaire "Computer" is designed to identify individuals who are prone to
compulsive gambling.
Questionnaire "Violences" is intended to identify individuals who are prone to violence in
the family.
The user may develop owns questionnaires on topics of interest to him and put them in the
installation directory \ VibraImage10 \ in the same file format ld_xxxxxx.ldg.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
124
Fig. 4.35. "Lie detection" mode operation. The questionnaires text display.
Adding questionnaire windows "LD Question" (Fig 4.36) to the screen is done by selecting
the menu item "View" – "Toolbar".
Download the survey questionnaire can be by selecting "LD load text... " in the "File" menu.
Allow withdrawal question text on the screen is made in the "S" information panel in "lie detection"
section by setting the parameter "Text" = Yes.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
125
Fig. 4.36. "Lie detection" mode operation. The choice questionnaires.
Pressing the button in the window allows you to start working with the questionnaire.
Double-click returns to the beginning of the work as a questionnaire and video.
Рис 4.37. Questionnaires process
Answers to these questions can be given a voice, if a premade microphone audio level
adjustment, or manually by pressing the button "Yes" and "No" when the self-test.
In self-test mode, the test man is in front of the monitor, which sees the image requirements
and questions. By selecting the button "Yes" or "No" on the screen (Fig. 4.37), responds to the test
questions are imposed in real time. When tested with a selection of the responses by pressing the
"Yes"/ "No" as a result of the test will also be analyzed in the time delay between a stimulus (question
asked, the image) and the response (answer).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
126
Please note, to answer this question only when the color of the question changes from black
to green. This time on the graphs corresponds to the green vertical line started lie detection. The
moment when the current question disappears from the screen corresponds the vertical line the red
color and end of the lie detection interval.
The proposed method allows to receive and to use for the automatic conclusion of psycho-
physiological information obtained 5 different independent methods during the three minute test:
1. Comparative information on psycho-physiological reaction of the test (similar to the
classical polygraph) in answering the relevant (Rc) and control (Rr) questions, that
includes an evaluation of the reaction of the test at the maximum level (max result)
of vibraimage parameters:
Rc > Rr; NDI (test is passed positively if total psychophysiological reaction at the
answer to control questions is higher, than at the answer to relevant questions);
Rc = Rr; INC (the test result isn't defined if total psychophysiological reaction at
the answer to control questions is approximately equal to reaction at the answer to
relevant questions);
Rc < Rr; DI (test is passed negatively if total psychophysiological reaction at the
answer to control questions is lower, than at the answer to relevant questions).
2. Comparative information on psycho-physiological reaction of the test (similar to the
classical polygraph) in answering the relevant (Rc) and control (Rr) questions, that
includes an evaluation of the reaction of the test at the average level (average result)
of vibraimage parameters (calculation is similar to a method 1).
3. Comparative information on psycho-physiological reaction of the test (similar to the
classical polygraph) in answering the relevant (Rc) and control (Rr) questions, that
includes an evaluation of the reaction of the test at the integrated level (integrated result)
of vibraimage parameters (calculation is similar to a method 1).
4. Information on the time delay in answering the questions. If the subject does not press any
of the buttons during the time set on this question, the system transitions to the next
question. According to the set algorithm absence of any response to the relevant questions
leads to a negative test result (calculation is similar to a method 1).
5. Information about changes in the dynamics of psycho-energetic (information-energy)
diagram of the test person at the answer to control and relevant questions. In more detail
the algorithm of calculation of this parameter is stated in the following section 5.1 of this
description.
According to set algorithm, the answer is YES to any of the relevant questions leads to a
negative test result.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
127
The calculation of the result of the test is carried out automatically with all the data. The data
calculation method 5 are used as the basic information. Results of the first four estimates change the
numerical value of reaction to relevant questions received by a method 5 according to the following
formula:
sRr=sR(5)r +0,1*sR(5)r*(∑NDI – ∑DI)
The result of psychophysiological testing is defined according to the following conditions:
NDI: sRr – sRc>0 or
NDI: sRr>0
DI: sRr– sRc<0
INC: 0,01<sRr – sRc < 0,01
4.4.8 Questionnaires stucture
According to the upgraded Bakster’s test of control questions questionnaire including three
blocks of control and relevant (test) questions (impact on the person can be strengthened by the
graphic information shown on the screen, the image of the pictures corresponding to a question) is
shown to the examinee person, general questions at the beginning and in intervals between which are
located. An example of such questionnaire indicating the time delay between the questions and the
type of questions used program is given below:
1. <GQ delay="10"length="7"text_delay="2"text_length="0"img="images/1.JPG"> Is your age over 20
years old?</GQ>
2. <GQ delay="5"length="7"text_delay="2"text_length="0"img="images/2.JPG"> Are you married or
single?</GQ>
3. <GQ delay="5"length="7"text_delay="2"text_length="0"img="images/3.JPG"> Are you ready to
answer truly the questions?</GQ>
4. <CQ delay="5"length="7"text_delay="2"text_length="0"img="images/4.JPG"> Earlier have you
been condemned for violations of the law?</CQ>
5. <RQ delay="5"length="7"text_delay="2"text_length="0"img="images/alco/5.JPG"> Do you justify
terrorist acts?</RQ>
6. <GQ delay="5"length="7"text_delay="2"text_length="0"img="images/6.JPG">Have you a
hobby?</GQ>
7. <CQ delay="5"length="7"text_delay="2"text_length="0"img="images/7.JPG"> Do you consider
yourself an honest and calm person?</CQ>
8. <RQ delay="5"length="7"text_delay="2"text_length="0"img="images/8.JPG"> Are you ready to
commit a terrorist act?</RQ>
9. <GQ delay="5"length="7"text_delay="2"text_length="0"img="images/9.JPG"> Are you a
believer?</GQ>
10. <CQ delay="5"length="7"text_delay="2"text_length="0"img="images/alco/10.JPG"> Are you ready
to do anything for money or people close to you?</CQ>
11. <RQ delay="5"length="7"text_delay="2"text_length="0"img="images/alco/11.JPG"> Are you ready
to support a terrorist, if he is your friend?</RQ>
12. <GQ delay="5"length="1"text_delay="2"text_length="0"img="images/alco/12.JPG"> Thank you for
your cooperation</GQ>
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
128
To reduce the uncertainty of comparative testing must have approximately the same time
interval upon presentation of the control and relevant questions, so the length of questions and pauses
when the synchronous presentation of a variety information needs to be given increased attention.
Tag "delay" sets the interval in seconds between questions. Tag "lenght" – the time interval of the
show text of the question. Tag "text_delay" delay before the question text painted. Tag
"text_lenght" determines the speed of text painting green, if value "0" the text is painted with a
constant speed depending on the number of letters in question, at other text is painted for a specified
time.
Note the "Img" tag in the structure of the questionnaire is optional. But properly selected
image (incentives) that the respondent sees on the screen increase its psycho-emotional response to
this question (see Fig. 4.38).
Fig.4.38. The image and question on the monitor in front of the examinee.
4.4.9 Create new questionnaires
User can be similar questionnaires on topics of interest to him and put them into the program's
installation folder in the same file format ld_xxxxxx.ldq by selecting "LD edit text..." in the main
menu. Then the window "LDQ" of creation of a new questionnaire will appear (fig. 4.39), where you
can enter questions and save profile by clicking "Save As".
To improve the efficiency of the questionnaire and increase the reaction of the test, you can
add an image corresponding to the question subject by clicking "img..." to the right of the question
in the window "LDQ" and selecting them from the pictures stored on your computer.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
129
Fig. 4.39 Creation of a new questionnaire
4.4.10 Psychophysiological detection of deception in semi-automatic mode without questionnaires
Using the proposed standard method of comparison areas (Bakcler test) , the user can create
their own thematic tests.
During the test operator notes control (by marker CQ) and relevant questions (by marker RQ)
by clicking on the corresponding toolbar button when passing these questions. After the test the
operator (the person asking the questions) presses the button [!] on the toolbar and instantly receives
a test result in "LDr" window: True (green column – NDI), False (red column – DI) or uncertain
(yellow column – INC).
Example of comparison zones test quantitative psychophysiological responses to control and
relevant questions shown in Figure 4.40.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
130
Fig. 4.40. Lie detection process with markers.
4.4.11 Psychophysiological detection of deception in semi-automatic mode, random questions
In "LD audio mode" user needs firstly to adjust "Audio Threshold" so that background
audio level must be lower than Audio Threshold and audio level of questions and answers must be
higher than Audio Threshold. In this case every question-answer response divided by time period not
less than 10 seconds from the next question-answer response is characterized by level of changes for
every measured psychophysiological parameter. The total changes in psychophysiological parameters
are characterized by two general indicators – P5 integral parameter indicated on the down graph, and
P20 differential parameter indicated on the vertical column. More quantity of P20 parameter after
response indicates more high level of psychophysiological response and gives more lie probability
for two response comparison.
4.4.12 Recording the main test LD results
Upon completion of the survey the system will automatically go into "Pause" mode to enable
the user to analyze the results on the screen (see Fig. 4.41). In the lies level window "LDr" will display
the final test result. For example, DI – the final test result is found "Lie"and the graphs at the answer
to questions 9 and 10 recorded high value P5 parameter (lie).
In "Lie level" window (LDr) on test results may be display 3 variants:
1. True (green column – NDI), then the test person has successfully passed the test.
2. False (red column – DI), it means that the test person has not passed the test.
3. Uncertainty (yellow column – INC), the test result is not clear, the test should be
repeated or modified.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
131
Fig. 4.41. LD test results
Note, Automatically save the results to a file is only available when operating in
"questionnaires" mode.
After completing the questionnaire in lie detection mode automatically in the selected
database directory \ VibraImage10 \ Database \ *** creates files with the test results:
Data_time_histH.png – frequency histogram.
Data_time_histT.png – an analysis of changes in the human psycho - emotional state
at the time of testing.
Data_time_histH.xml – system settings and change the basic parameters of the psycho
-emotional state of a person
Data_time_LD.txt – lie detector report and result files
Data_time_row.txt – Full record values recorded vibraimage system parameters. This
file can be used for statistical research and testing of algorithms for determining the
psychophysical and psychoemotional human condition.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
132
4.4.12.1 Graphics of psychophysiological state changes
Changing of psychoenergetic state of a person to a controlled period of time clearly displayed
on the graph (see. fig. 4.42) and in file Data_time_histT.png. Only a person who is in a relaxed or
in a state of high concentration may be in a fixed psychoenergetic state during such insignificant time
as 1 minute. Most of the people make a noticeable fluctuations of psychoenergetic state, even for
short periods of time, depending on their thoughts and under the influence of the environment.
Color line of psychoenergetic state changes corresponds to the "color" of the test question:
general questions – blue;
control questions – green;
relevant questions – red.
Fig. 4.42. Periodic change psychoenergetic state along a certain trajectory, usually
characteristic for an interview, type a question-answer
Actual psychophysiological state is displayed in the form of a point and change of person’s
psychophysiological state in time is displayed in the form of a straight line or a curve between two
points. The example of psychophysiological state change from a state 0 in various states 1, 2, 3, 4, 5
is given in figure 4.43 and each transition has its emotional and psycho-physiological sense.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
133
Fig. 4.43 Psychoenergetic (information-energy) diagram of the psychophysiological state.
Transition 0 – 1 is characterized by an increase in energy consumption and improvement of
psychological state. The reason of this psychophysiological state change can be a good or pleasant
news (the stimulus), it leads to a more intensive exchange processes (increase in energy
consumption), and the psychological condition and mood notably improved.
Transition 0 – 2 is characterized by an increase in energy consumption and an even level of
psychological state. The reason can be, for example, an increase in mental and physical activity,
which lead to more intensive exchange processes (increase in energy consumption), at the same time,
the psychological state and mood are unchanged, as conducted by the impact did not cause emotional
changes.
Transition 0 – 3 is characterized by an increase in energy consumption and impairment of
psychological state. The reason can be unpleasant information that leads to a more intensive exchange
processes (increase in energy consumption), and the psychological condition and mood became
notably worse.
Transition 0 – 4 is characterized by a decrease in energy consumption and impairment of
psychological state. The reason can be unpleasant information that leads to a slowing of metabolic
processes (reducing energy consumption), and the psychological condition and mood became notably
worse.
Transition 0 – 5 is characterized by a decrease in energy consumption and improvement of
psychological state. The reason can be pleasant news, which soothes and slows down the metabolic
processes (reducing energy consumption), and the psychological condition and mood are notably
improved.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
134
Vibraimage technology allows to obtain multi-dimensional relationship of a
psychophysiological state characteristics and to measure not only the energy change but also the
direction of this change.
For example, The psychophysiological reactions of the person at the answer to the control
(CQ) and relative questions (RQ) are compared. In answering the question person
psychophysiological state, displayed on the diagram changes from the point with coordinates (E1, I1)
to a point with coordinates (E2, I2).
ER = E1 – E2
IR = I2 – I1
Below we consider the situation where the respondent did not like the question, he's going to
say a lie on it. Energy state in such case increases, i.e. ER < 0, and the psychological comfort is
reduced, and IR > 0.
Comparison of the sum of these indicators for answers to relevant and control questions allows
to define truthfulness of the answer or psycho-energetic expenses at reaction to the shown answers or
incentives.
R = IR + ER
If a difference Rr – Rc = dR < 0, then the person has told a lie (DI) or reacted negatively to
the shown incentive.
Hereinafter the lower indexes «r"designate value of measurement for relevant questions, and
"c" – for control questions.
The results of the human psycho-physiological reactions than the test on the 3 group of control
and relevant questions is contained in a lie detection report file in the section "IE result".
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
135
4.4.12.2 Recording the main test results
The main results of change of psychophysiological state when carrying out
psychophysiological testing saved in the text file which structure is given in figure 4.44.
################################################################
Area 1 ###### 1 RQ 02.02.2016 10:48:53 video: 91.7935
Have you been delayed at work today?
################################################################
Start time 02.02.2016 10:48:53 Video timer (start) 01:32
Stop time 02.02.2016 10:49:03
Video timer (stop) 01:42
LD time 02.02.2016 10:49:00
LD video timer 01:38 ################################################################
Name cMin bMin cMax bMax vRates cRates
A1X 0,000150238 7,55247e-005 0,0771637 0,0282315 1 -2 A1 0,00409047 0,000426037 0,549241 0,066692 1 -1
A2 20,1334 10,0224 86,2681 19,5487 1 -1
A3 A4X 0,000251693 0,000198452 0,0242119 0,00419498 1 -1
A4 0,0278119 0,00656809 0,253695 0,0292217 1 1
F1X 3,61082e-005 1,96954e-005 0,00541951 0,00272781 1 1 F1D -0,00291492 -0,00152639 0,00382747 0,0026162 2 2
F1 0,00142904 0,000123698 0,048903 0,0132878 1 -1
F2 54,607 40,606 78,4315 55,9861 1 1 F3
F4 102,544 94,83 151,742 124,894 1 -1
F5X 0,16845 0,321748 0,399377 0,484708 1 1
F5
F6 0,150574 0,124949 0,199305 0,152812 1 -1
F7 0,0596623 0,031001 0,114005 0,0664505 1 1 F8 0,0384835 0,0491532 0,386444 0,268609 2 2
F9
S1 -131,267 -83,3541 139,172 86,3353 2 1 S2 -18,3586 -9,66255 1,47161 7,26032 1 -1
S3 -0,916659 -0,710579 0,775945 -0,212643 2 2
S4 S5
S6 -0,131085 -0,119924 0,0736296 -0,0764681 1 1
S7 -25,2939 -26,4201 -10,6387 -14,2742 1 0 P1
P2 23,6709 25,6102 26,8731 26,7899 2 -1
P3 0,266011 0,207058 1,40152 0,509807 1 1 P4
LD 4
################################################################
Audio
Level 31,1 Threshold 5,0
Delay (s) 0,00
################################################################
R(m) 4
R(a) 46.4286
tR(i) 357.615
###### 1 RQ 02.02.2016 10:49:03 END
Fig. 4.44. Example of the beginning of the text file with the first relevant question (RQ).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
136
"Area 1" contains information about the test questions. The text of the question, its serial
number, the type of the question (GQ general,CQ control, RQ relevant), and the time when, during
the question was the maximum value of the parameter P5 (LD Time).
Also for each question are given values of the parameters that have exceeded the established
bMin and bMax limits, and the "weight parameters"in the calculation of the lie level – vRates (for P5
calculation) and cRates (for P20 calculation).
Than shows the sym cRates for all parameters, whitch values are deliated from norm, for
example, LD = -2 – 1 – 1 – 1 + 1 + 1 + 2 – 1 + 1 – 1 + 1 – 1 + 1 + 2 + 1 – 1 + 2 + 1 + 0 – 1 + 1 = 4
At the end of the field shows the resulting measurement valuesfor each answer, calculated in
three ways :
R(m) 4 (max result) – results from the analysis of the parameter P20;
R(a) 46.4286 (average result) – results from the analysis of the parameter P5;
tR(i) 357.615 (integrated result) – results based on the analysis of the area under the
graph of the parameter P5.
At the end of the common text file shows the results of all measurements (Fig. 4.45).
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
137
######################## max result
RQ(m) 7,00 3
RQ(m) stat: 4,00 0,00 3,00
CQ(m) 7,00 3
CQ(m) stat: 5,00 1,00 1,00
LD(M) INC
######################## average result
RQ(a) 39,29 3
RQ(a) stat: 46,43 28,57 42,86
CQ(a) 34,52 3
CQ(a) stat: 33,93 32,14 37,50
LD(a) DI
######################## integrated result
RQ(i) 275,93 3 RQ(i) stat: 357,62 190,76 279,41
CQ(i) 211,47 3 CQ(i) stat: 214,99 189,43 229,97
LD(i) DI
######################## dT result
Q1: Tc=3.967 Tr=5.666 DI Q2: Tc=6.067 Tr=5.233 NDI
Q3: Tc=1.534 Tr=1.900 DI
dT result: sTc=11.568 sTr=12.799 INC
######################## IE result
Qc1: E1=0.298 E2=0.263 ERc=0.035
I1=0.527 I2=0.553 IRc=0.026
Qr1: E1=0.262 E2=0.278 ERr=-0.016 I1=0.554 I2=0.615 IRr=0.061
Rc=0.062 Rr=0.045 dR=-0.017 DI
Qc2: E1=0.300 E2=0.260 ERc=0.040
I1=0.557 I2=0.586 IRc=0.028 Qr2: E1=0.260 E2=0.256 ERr=0.003
I1=0.589 I2=0.587 IRr=-0.001
Rc=0.068 Rr=0.002 dR=-0.066 DI
Qc3: E1=0.217 E2=0.234 ERc=-0.017 I1=0.530 I2=0.522 IRc=-0.007
Qr3: E1=0.236 E2=0.292 ERr=-0.056
I1=0.527 I2=0.636 IRr=0.109
Rc=-0.024 Rr=0.053 dR=0.076 NDI
IE result: sRc=-0.063 sRr=-0.181 DI
IE final: sRc'=-0.063 sRr'=-0.181 DI=0 NDI=0
######################## global result
LD result INC
Fig. 4.46. Example of LD results file.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
138
The decision is considered the sum of "weights"on relevant RQ question and CQ control
question. If Σ (RQ)> Σ (CQ), a person tells a lie (DI).
Max result – assessment of psycho-physiological reactions to stimuli is carried out taking
into account the various factors of vibraimage parameters significance (RateC).
Average result – average assessment of psycho-physiological reactions to stimuli is carried
out taking into account the equal factors of vibraimage parameters significance (RateV).
Integrated result – integral assessment of psycho-physiological reactions to stimuli is carried
out taking into account the equal factors of vibraimage parameters significance (RateV).
IE result. Analysis of changes in psycho-energetic state of a person in the process of response
(Fig. 4.39). We compare the physiological response to the control and relevant questions.
dT result. At the end of the file is an analysis of the time delay (in seconds) in answering to
the control (Tc) and the relevant (Tr) questions. Then longer a person is thinking about the answer,
than more likely a lie.
Note, if the camera settings and shooting conditions are wrong, then at the end of the question,
and at the end of the file appears message on the specific reasons for the error with the quantitative
contribution to the overall quality.
Warning: Low quality (1) ! [0.35%]
Warning: Low quality (2) ! [13.66%]
Warning: Low quality (3) ! [18.06%]
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
139
4.4.13 Ranking mode of reactions to questions
In contrast to the mode of comparative testing (comparison test zones proposed by Clive
Bakster) for many variants of psychological and psychophysiological testing necessary to obtain
information about the degree of importance of the various questions for the test person. In this case,
using a questionnaire R_Test program shows the absolute (not relative) the test reactions to questions.
In the text of the questionnaire all the questions marked with the tag <EQ>, for example :
<EQ delay="5"length="7"text_delay="1"text_length="0"> Are you often change the decision
?</EQ>
After completing the questionnaire in lie detection mode automatically in the selected
database directory \ VibraImage10 \ Database \ *** creates files with the test results :
Data_time_histH.png – frequency histogram.
Data_time_histT.png – an analysis of changes in the human psycho - emotional state
at the time of testing.
Data_time_histH.xml – system settings and change the basic parameters of the psycho
-emotional state of a person
Data_time_LD.txt – lie detector report and result files
Data_time_row.txt – Full record values recorded vibraimage system parameters. This
file can be used for statistical research and testing of algorithms for determining the
psychophysical and psychoemotional human condition.
Data_time_LD_e.txt - An additional file with the results of ranking the importance
of questions for the test
An example of the calculation results of the file with the ranking table is shown in figure 4.47.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
140
----------------matrix table--------------------------------------
R A I S S1 At It M
1 9 2 12 12 12 4 7
2 6 4 4 4 5 2 6
3 5 9 1 5 6 5 9
4 4 1 5 10 4 10 3
5 2 5 10 6 9 9 12
6 1 8 6 9 10 6 10
7 10 6 9 2 2 8 8
8 12 10 2 3 3 3 11
9 8 7 3 8 7 12 4
10 7 11 8 7 1 1 2
11 11 3 7 1 11 7 1
12 3 12 11 11 8 11 5
----------------results of ranking--------------------------------------
R: 4 (24), 9 (30), 6 (31), 5 (32), 12 (37), 2 (40), 10 (40), 1 (55), 3 (60), 8 (60), 7 (61), 11 (76)
---------------- formula calculation for 7 algorithms-------------------------------------
A: P5 [ t' = t(max(P5)) ]
M: P20 [ t' = t(max(P5)) ]
I: Ʃ P5
S: A/(t(max(P5))-t(P5>0))
S1: A/t(max(P5))
At: A/dt
It: I/dt
Fig. 4.47. The results of the ranking of psycho-physiological reactions in answering to questions
The number of rows in a matrix table is the number of questions in the questionnaire. The top
line in the table shows the number of questions that caused the maximal response of the subject.
The number of columns is 7 – as the number of used calculating algorithms (A, I, S, S1, At,
It, M). Formula each algorithm are shown in the lower part of the log file. In each column the number
of questions in order of their importance (human response). The higher the number of the question in
the column cells, the more psycho-physiological reaction to it showed during the test.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
141
In the "results of ranking" section shows the importance of the overall performance of each of
the questions asked. For example, the question №4 is rated the lowest from all the remaining question
and equal to 24, i.e. in answering this question the testing human showed the biggest reaction.
4(24) – question №4 (its reaction = 1 (string number) *1 (the number of repetitions of the
question number in the string)+ 2*3 + 4*2+ 9*1 = 1+6+8+9 = 24)
4.4.14 Video recording during testing and mark standing
To save the results of the lie detection, system settings and all the changes in an external file,
is necessary to set the "Save LD" = YES in the information panel in the DB mode (see Fig. 4.61), as
well as at the beginning of the test, press the video record button in the toolbar. Note, the video
recording must be performed even in the case where no information source is a video camera, and the
outer AVI file. Along with the video record will be generated a text file with the results of lie
detection, and system settings.
After the end of the experiment should stop file recording by pressing the button in the toolbar.
Fig. 4.48. Including files recording mode with the results of lie detection
A detailed analysis and methodology of work of psychophysiological lie detector using
vibraimage system is contained in a special supplement to this description (optional). Special
description of lie detection is provided to users who have completed training in lie detection.
Thus, the analysis of the video file is recommended to perform the following steps:
1. Select the directory for writing the research results.
2. Set the options "Save XML" = YES and "Save LD" = YES to create a results file .
3. If necessary, change the lie detector settings in the tabs of the dashboard .
4. Choose the method of calculating the level of lies .
5. Enable lie detection .
6. Open the video image for analysis.
7. Set the parameter "Set marker" = YES for manual entry markers (CQ, RQ, GQ).
8. Double-click the button to the axis of the graphs corresponds to the dimension of the
horizontal full length video file.
9. Press the button to start recording the results.
10. Once you click to jump to the beginning of the test file.
11. Start the analysis of the video file, placing CQ, RQ, GQ marks in the right places.
12. When the end of the video file, press the button
13. Reset input parameter "Set marker" markers = NO
14. In the selected directory will be created file * _LD.txt with the results of lie detection and
* .xml file with the system settings for viewing in VILogViewer.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
142
5 Operation with external devices
The VibraImage 10 program have the ability to synchronize other devices recording
physiological parameters of the person with the VibraImage system. The synchronous registration of
different physiological processes allows expanding significantly possibilities of research of
psychophysiological and physiological characteristics of the person. Joint and synchronous
registration with the vibraimage of a pulse wave (DC21U scanner) and an electroencephalography
(Mitsar-EEG-201) allows watching visually correlation and correlation of functioning of different
physiological systems of the person.
5.1 Operation with EEG devices
Technology electroencephalography (EEG) is the most famous and informative for
psychophysiological testing. Therefore, it is EEG was chosen as the technology for comparative
testing vibraimage. Software VibraImage implements a joint synchronous registration and processing
of the signals of electrical activity (EEG) and motor activity (vibraimage). It should be noted that the
registered signals due to mechanical inertia of vibraimage are lower frequency than the EEG signals,
so the correct definition of the correlation between the signals should be carried out in the frequency
range up to 10 Hz.
To working EEG (for example Mitsar-EEG-10/70-201) it is not require the installation of
additional software or drivers. Enough after connecting EEG to choose an item "Mitsar-EEG". When
you connect EEG in information panels "GR" and "С" there will be additional points output of
diagrams and correlation of the following parameters:
EEG_FP1, EEG_FP2, EEG_FPZ, EEG_F3, EEG_F4, EEG_F7, EEG_F8, EEG_FZ, EEG_Т3,
EEG_Т4, EEG_Т5, EEG_Т6, EEG_С3, EEG_С4, EEG_СZ, EEG_P3, EEG_P4, EEG_PZ,
EEG_PG1, EEG_PG2, EEG_O1, EEG_O2, EEG_OZ, EEG_NZ, EEG_BIO1-EEG_BIO8,
EEG_AADIFF, EEG_EVENT.
The figure 5.2 shows an example of viewing graphs of electrical impulses from the EEG in
VibraImage 10.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
143
a) b)
Fig. 5.1 New items when connecting EEG:
а) – in the “GR" information panel mode, b) – in the "C" information panel mode
Fig. 5.2. View information from the EEG
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
144
5.2 Operation with a fingerprint scanner and registration of the pulse wave.
Under development.
To use the fingerprint scanner is required initially to install the drivers. The procedure to install
drivers fingerprint scanner DC21U described in detail in the description Biofinger system
(http://www.psymaker.com/downloads/BiofingerManualEng.pdf) in the section "Fingerprint scanner
DC21U driver installation".
Note, to install the DC21U drivers, you must have administrator rights.
You can get to work after connecting a fingerprint scanner to your PC. In the VibraImage 10
program you need choose an item «DC21"in the submenu "Settings". After that there will be a
program window DCРulse (fig. 5.5). It is possible to view and process all diagrams of the program
DCPulse reflecting pulse in different points of a fingerprint figure in the VibraImage 10. When you
connect a fingerprint scanner in information panels "GR" and "С" there will be additional points
(fig. 5.4) output of graphs and correlation of the following parameters:
Pulse AVG_ALL, Pulse SIGMA_ALL, Pulse AVG_ZONE1, Pulse AVG_ZONE2, Pulse
SIGMA_ZONE1, Pulse SIGMA_ZONE2, Pulse AVG_LINE1 - Pulse AVG_LINE3, Pulse
SIGMA_LINE1 - Pulse SIGMA_LINE3, Pulse SIN, Pulse PHASE T, Pulse PHASE A, Pulse PULSE
10, Pulse AVG_X0 - Pulse AVG_X9, Pulse SIGMA_X0 - Pulse SIGMA_X9.
a) b)
Fig. 5.4 New items when connecting fingerprint scanner DC_21:
а) – in the "GR" information panel mode, b) – in the "C" information panel mode.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
145
Fig. 5.5 Window DCPulse program.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
146
6 Vibraimage. General info
Values of amplitude and frequency of vibrations of a person head differ in each point of space
and are displayed as pseudo color image. Integrated processing of parameters values of vibration in
each point can give the general information on parameters of the person movement.
As against amplitude analyses, each point frequency vibraimage has physical dimension
frequencies (Hz) as really displays frequency of signal change in each element of the image.
Therefore, the resulted color scale (fig. 6.1) scaling in Hz, i.e. violet color frequency vibraimage
displays a range of vibrations (0 – 1) Hz, dark blue displays a range of vibrations (1 – 4) Hz, green
the range of vibrations displays (4 – 8) Hz, red displays a range of vibrations (8 – 10) Hz.
Red- activity and aggression color.
Yellow – trouble and tension color
Green- normal activity and top condition color
Blue- rest and calm color
Fig. 6.1. Pseudo color scale of frequency distributions
External (around of a head) interline display of the maximal frequency and average amplitude
vibraimage looks as aura and more informatively displays a condition of the person, than internal
vibraimage. Color of vibra-aura is coded by the same color scale, as vibraimage (fig. 6.2), and
displays the maximal frequency in each line. The size of aura is defined by average amplitude for the
given line. Any non-uniformity in color and the size of aura characterizes movements of object and
its emotion condition. The normal condition of the person(see Fig. 6.2) is characterized more uniform
external vibraimage (vibra-aura), and for an stress condition (see Fig. 6.3)of the person are
characteristic the big space and color non-uniformity of vibra-aura.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
147
Fig. 6.2. External vibraimage (vibra-aura) of
person in normal condition
Fig. 6.3. External vibraimage (vibra-aura) of
person in tension condition
Brief aura form analysis
1. Any aura asymmetry (form, color) characterized deviation from mental or physiological
norms.
2. Color irregularity of vibra-aura characterizes psycho-physiological imbalance of a person
status.
3. Any breaks in aura uniformity characterized deviation from mental or physiological norms.
4. Ideal aura has mono color, symmetrical and uniform. Any real aura differs from ideal and the
question of interpretation is to characterized real aura deviations.
Note!
This brief aura interpretation correspond default vibraimage system settings and based on
main rules for right vibraimage scanning:
uniform and stable object illumination;
high quality and low nose camera application;
frontal plane object before camera;
maximum facial image size on monitor;
mechanical stabilization of camera.
For more information about the basics of vibraimage technology, refer to the book Vibraimage
of Viktor Minkin, St. Petersburg, Renome publishing, 2017
More detailed information on basic modes of operation, preparation for work with the system,
the analysis of various human conditions, see the "Behavior Detection System VibraImage 8.
Manual", http://www.psymaker.com/downloads/VI8_1ManualEng.pdf
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
148
7 Warranty
Maintenance service and service regulations of VibraImage 10 system is carried out according
to this Manual and instructions of used hardware maintenance (a computer, the camera, etc.).
ATTENTION!
Information in this document is subject to change without notice and does not represent the
commitment on the part of Elsys Corp. No part of this manual maybe reproduced or transmitted in
any form or by any means, electronic or mechanical, for any purpose without written permission of
Elsys Corp. The software VibraImage 10 described in this document is furnished under license
agreement and maybe used only in accordance with the terms of the license agreement. It is against
the law to copy the software or any other medium except as specifically allowed in license agreement.
The licensee may make one copy of vibraimage software for backup purposes.
7.1 Disclaimer of Warranties
You expressly acknowledge and agree that, to the extent permitted by applicable law, use of
the Vibraimage software and services is at your sole risk and that the entire risk as to satisfactory
quality, performance, accuracy and effort is with you. To the maximum extent permitted by applicable
law, the VibraImage 10 software and services performed by the VibraImage 10 software are provided
"as is" and "as available", with all faults and without warranty of any kind, and Elsys and Elsys’
licensors (collectively referred to as "Elsys" for the purposes of sections 7 and 8) hereby disclaim all
warranties and conditions with respect to the VibraImage 10 software and services, either express,
implied or statutory, including, but not limited to, the implied warranties and/or conditions of
merchantability, satisfactory quality, fitness for a particular purpose, accuracy, quiet enjoyment, and
non-infringement of third party rights. Elsys does not warrant against interference with your
enjoyment of the VibraImage 10 software and services, that the functions contained in or services
performed by the VibraImage 10 software will meet your requirements, that the operation of the
VibraImage 10 software and services will be uninterrupted or error-free, that any service will continue
to be made available, that defects in the VibraImage 10 software or services will be corrected, or that
the VibraImage 10 software will be compatible or work with any third party software, applications
or third party services. Installation of this software may affect the usability of third party software,
applications or third party services. You further acknowledge that the VibraImage 10 software and
services are not intended or suitable for use in situations or environments where the failure or time
delays of, or errors or inaccuracies in, the content, data or information provided by the VibraImage 10
software or services could lead to death, personal injury, 1 or severe physical or environmental
damage, including without limitation the operation of nuclear facilities, aircraft navigation or
communication systems, air traffic control, life support or weapons systems. No oral or written
information or advice given by Elsys or an Elsys authorized representative shall create a warranty.
Should the VibraImage 10 software or services prove defective, you assume the entire cost of all
necessary servicing, repair or correction. Some jurisdictions do not allow the exclusion of implied
warranties or limitations on applicable statutory rights of a consumer, so the above exclusion and
limitations may not apply to you.
VibraImage10 Copyright © 2019 by Elsys Corp. All rights reserved.
149
7.2 Limitation of Liability
To the extent not prohibited by applicable law, in no event shall Elsys be liable for personal
injury, or any incidental, special, indirect or consequential damages whatsoever, including, without
limitation, damages for loss of profits, corruption or loss of data, failure to transmit or receive any
data, business interruption or any other commercial damages or losses, arising out of or related to
your use of or inability to use the VibraImage 10 software and services or any third party software or
applications in conjunction with the VibraImage 10 software, however caused, regardless of the
theory of liability (contract, tort or otherwise) and even if Elsys has been advised of the possibility of
such damages. Some jurisdictions do not allow the limitation of liability for personal injury, or of
incidental or consequential damages, so this limitation may not apply to you. In no event shall Elsys’
total liability to you for all damages (other than as may be required by applicable law in cases
involving personal injury) exceed the amount of twenty five dollars (U.S. $25.00). The foregoing
limitations will apply even if the above stated remedy fails of its essential purpose.