4
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS WEBSITE: www.jdsu.com Is this pair suitable for your VDSL2 system? ELQ 30 VDSL Copper Qualifier gives the answer! ELQ 30 VDSL Copper Qualifier Key Features Parameter set edition with or without PC •Single end measurements 30 MHz frequency range for fix-frequency and spectrum measurements Long time wide band and impulse noise measurements with histogram Test results can be stored in memory and transferred to PC PC program is provided to produce detailed test protocols in Excel format 320 x 240 LCD display with backlight Internal rechargeable battery with an operating time of approx. 8 hours Processor controlled battery manager with three hour fast charging facility Selectable English, German or Russian language Acoustic pair detection facility Service telephone facility TDR for fault location (option) Micro interruption measurements (option) Applications ELQ 30 is a hand held battery operated, multifunction measuring instrument, intended for pre- qualification, installation, fault location and maintenance of balanced copper pairs. To qualify a pair with end-to-end measurements, two instruments can be used in MASTER- SLAVE mode. Just one person, thanks to the communication between the two instruments, can perform the measurement tasks. Operation is made extremely simple with pre-defined automatic test sequences. Tolerance masks of cable parameters as Loss, LCL, Return Loss, Impedance, and the principal sys- tem parameters are pre-programmed for several VDSL systems. New user defined template sets can be created with the parameter editor of ELQ 30 without PC. (PC program is also available.) The automatic test sequence of the ELQ 30 provides an immediate PASS/FAIL indication by com- paring the test results with the tolerance masks and the required data rate with the calcu-lated theoretically achievable bit rate. Detailed test results are available in graphic and numeric forms. In case of FAIL indication the rea- son of failure is indicated with asterisks. Physical parameter measurements to pre-qualify copper wire pairs for high bit rate VDSL services before the installation of modems Automatic test sequences with preprogrammed or user defined test parameter sets belonging to different VDSL systems Bit rate calculation for each VDSL system PASS/FAIL indication Measurements

ELQ 30 VDSL Copper Qualifier€¦ · •TDR for fault location (option) •Micro interruption measurements (option) Applications ELQ 30 is a hand held battery operated, multifunction

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ELQ 30 VDSL Copper Qualifier€¦ · •TDR for fault location (option) •Micro interruption measurements (option) Applications ELQ 30 is a hand held battery operated, multifunction

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS

WEBSITE: www.jdsu.com

Is this pair suitable for your VDSL2 system?

ELQ 30 VDSL Copper Qualifier gives the answer!

ELQ 30VDSL Copper Qualifier

Key Features • Parameter set edition with or without PC•Single end measurements• 30 MHz frequency range for fix-frequency and spectrum

measurements• Long time wide band and impulse noise measurements with

histogram• Test results can be stored in memory and transferred to PC • PC program is provided to produce detailed test protocols in

Excel format• 320 x 240 LCD display with backlight• Internal rechargeable battery with an operating time of

approx. 8 hours• Processor controlled battery manager with three hour fast

charging facility• Selectable English, German or Russian language• Acoustic pair detection facility• Service telephone facility• TDR for fault location (option)• Micro interruption measurements (option)

Applications

ELQ 30 is a hand held battery operated, multifunction measuring instrument, intended for pre-qualification, installation, fault location and maintenance of balanced copper pairs.

To qualify a pair with end-to-end measurements, two instruments can be used in MASTER-SLAVE mode. Just one person, thanks to the communication between the two instruments, can perform the measurement tasks. Operation is made extremely simple with pre-defined automatic test sequences.

Tolerance masks of cable parameters as Loss, LCL, Return Loss, Impedance, and the principal sys-tem parameters are pre-programmed for several VDSL systems.

New user defined template sets can be created with the parameter editor of ELQ 30 without PC. (PC program is also available.)

The automatic test sequence of the ELQ 30 provides an immediate PASS/FAIL indication by com-paring the test results with the tolerance masks and the required data rate with the calcu-lated theoretically achievable bit rate.

Detailed test results are available in graphic and numeric forms. In case of FAIL indication the rea-son of failure is indicated with asterisks.

• Physical parameter measurements to pre-qualify copper wire pairs for high bit rate VDSL services before the installation of modems• Automatic test sequences with preprogrammed or user defined test parameter sets

belonging to different VDSL systems• Bit rate calculation for each VDSL system• PASS/FAIL indication

Measurements

Page 2: ELQ 30 VDSL Copper Qualifier€¦ · •TDR for fault location (option) •Micro interruption measurements (option) Applications ELQ 30 is a hand held battery operated, multifunction

2

ELQ 30 VDSL COPPER QUALIFIER

Automatic Measurements with two instruments

• Loss• Noise spectrum • Bit load calculation • Achievable bit rate calculation• LCL • Return loss • Impedance• NEXT• FEXT

Manual Measuring Modes

• Transmitting/Receiving• NEXT• LCL • Impedance• Return loss • Weighted noise• Spectrum• Impulse noise• Fault Location with TDR (option)• Micro interruption measurements

(option)

Preprogrammed VDSL 2 parameter sets

Page 3: ELQ 30 VDSL Copper Qualifier€¦ · •TDR for fault location (option) •Micro interruption measurements (option) Applications ELQ 30 is a hand held battery operated, multifunction

3Specifications

ELQ 30 VDSL COPPER QUALIFIER

Transmitter

Frequency range 25 kHz to 30 MHzResolution 4.3125 or 5 kHzImpedance 100, 120, 135 or 150 ΩTransmitting modes:Generation of 1 single frequencyGeneration of 30 frequencies at the same timeOutput levelIn 1 frequency mode -10 to +10 dBmIn 30 frequency mode -12 dBm/frAccuracy at 0 dBm25 kHz to 100 kHz ± 1 dB100 kHz to 5 MHz ± 0.3 dB5 MHz to 30 MHz ± 1 dB

Receiver

Frequency range 25 kHz to 30 MHzReceiving modes 1 or 30 frequencyResolution 4.3125 or 5 kHzImpedance 100, 120, 135, 150 ΩReceiving modes:Receiving of 1 single frequencyReceiving of 30 frequencies at the same timeMeasuring range +10 to -100 dBmAccuracy at 0 dBm25 kHz to 100 kHz ± 1 dB100 kHz to 5 MHz ± 0.3 dB5 MHz to 30 MHz ± 1 dB

LCL measurement

Frequency range 25 kHz to 30 MHzImpedance 100, 120, 135 or 150 ΩDisplay range 0 to 70 dBAccuracy at 35 dB with special balanced cable25 kHz to 100 kHz ± 2 dB100 kHz to 5 MHz ± 1 dB5 MHz to 30 MHz ± 2 dB

Impedance measurement

Frequency range 25 kHz to 30 MHzMeasuring range 50 Ω to 400 ΩAccuracy100 kHz to 30 MHz 5% ± 5 Ω

Return loss measurement

Frequency range 25 kHz to 30 MHzImpedance 100, 120, 135 or 150 OhmMeasuring range up to 40 dBAccuracy at 20 dB100 kHz to 5 MHz ± 1 dB5 MHz to 18 MHz ± 2 dB

NEXT, FEXT, loss measurement

Frequency range 25 kHz to 30 MHzResolution 4.3125 or 5 kHzImpedance 100, 120, 135 or 150 ΩMeasuring rangeNEX, FEXT up to 80 dBLOSS up to 90 dB

Spectrum analyzer

Frequency range 25 kHz to 30 MHzMeasuring range down to -140 dBm/HzImpedance 100, 120, 135, 150 Ω or 5 kΩ II 5 pF with high impedance probeBandwidth/ frequency stepRange MHz

Bandwidth/ frequency stepkHz

30 100/100 50/50 20/20 10/10 5/5 5/2.518 60/60 20/20 10/10 5/5 5/2.512 40/40 20/20 10/10 5/5 5/2.59 30/30 15/15 10/10 5/5 5/2.53 10/10 5/5 5/2.51.5 5/5 5/2.5

Number of Displayed frequencies 300Saving of result the actual content of displayEvaluation Normal, Peak, AverageUnits dBm, dBm/Hz

Wideband noise measurement

Frequency range 25 kHz to 30 MHzImpedance 100, 120, 135, 150 OhmFilters for noise measurement ADSL ADSL 2+ VDSL VDSL2-8 VDSL2-17 VDSL2-30 NO FILTERMeasurement times 1, 5, 10, 30 sec 1, 5, 10, 30 min 1, 2, 4, 8, 12, 24, 48, 72 hoursEvaluationFor 1 sec to 1 min Quasi analogOver 1 min Histogram with 60 time slots

Impulse noise measurement

Impedance 100, 120, 135, 150 ΩPulse width >500 nsInterval size 10 msThreshold range 0 to -60 dBmMaximum count 65000Measurement times 1, 5, 10, 30 sec 1, 5, 10, 30 min 1, 2, 4, 8, 12, 24, 48, 72 hoursEvaluationFor 1 to 30 s NumericOver 30 s Histogram with 60 time slots

High impedance active probe (option)

Frequency range 25 kHz to 30 MHzAttenuation 15 dBInput Impedance: 5 kΩ II 5 pFAccuracy 25 kHz to 5 MHz ± 0.3 dB12 MHz to 30 MHz ± 1dB

Fault location with TDR (option)

Measuring modesSingle pairSingle pair long timeComparison to memoryXTALKMeasuring ranges 100 m to 5 kmAccuracy ± 1% ± 1 mZoom 1 to 4Propagation velocity (V/2) 45 to 150 m/µsGain range 0 to 60 dBMeasuring pulseAmplitude ~3 V into 100 ΩWidth 10 to 2.5 µs

Micro interruption measurement (SW option)

Test SignalFrequency 25 kHz ± 100 HzInput level from 0 to –30 dBmImpedance 100, 120, 135, 150 OhmSelectable thresholdBelow the normal input level 3, 6, 10, 20 dBAccuracy of thresholdFor 3, 6, 10 dB ± 1 dBFor 20 dB ± 2 dBMeasuringTime adjustable. 4 min to 72 hours 4, 8, 12, 24 min 1, 2, 4, 8, 12, 24, 48, 72 hourInterruption categories 0.3 ms to 3 ms 3 ms to 30 ms 30 ms to 300 ms 300 ms to 1 min >1 minEvaluation Relative duration, errored s Count & time distribution/category

ADSL measurements (SW option)

Preprogrammed parameter setsADSL FDD over ISDN and over POTS ADSL (ITU-T G.992.1) 2, 4, 6 MbpsADSL2 (ITU-T G.992.3) 4, 6, 8 MbpsADSL2+ (ITU-T G.992.5) 8, 16, 24 Mbps

General specifications

Power supply

Internal rechargeable NIMH battery packOperation time approx. 8 hours (Without backlight)

Charging

(Without taking the battery pack out)From 230V mains with mains adapterFrom 12V car battery with car adapterFast charging time less than 3 hoursDisplay 320 × 240 LCD with backlight

Page 4: ELQ 30 VDSL Copper Qualifier€¦ · •TDR for fault location (option) •Micro interruption measurements (option) Applications ELQ 30 is a hand held battery operated, multifunction

Test & Measurement Regional Sales

NORTH AMERICATEL: 1 866 228 3762FAX: +1 301 353 9216

LATIN AMERICATEL:+55 11 5503 3800FAX:+55 11 5505 1598

ASIA PACIFICTEL:+852 2892 0990FAX:+852 2892 0770

EMEATEL:+49 7121 86 2222FAX:+49 7121 86 1222

WEBSITE: www.jdsu.com

ELQ 30 VDSL COPPER QUALIFIER

Product specifications and descriptions in this document subject to change without notice. © 2008 JDS Uniphase Corporation 30137303.003.0608.ELQ30VDSL.DS.CPO.TM.AE

Connectors

For mains or 12V car adapter 2.1/5.5 mm coaxialPower supply for active probe Mini-din-4PFor L1 and L2 line 4 mm banana socketsGround connector 4 mm banana socketUSB A USB 1.1 host port for USB stickUSB B USB 1.1 device port to connect PCOver voltage protectionBetween a and b or ground 500 V DCLongitudinal voltage 60 V AC

Ambient temperature ranges

Reference 23 ± 5°CRel. humidity 45% to 75%Normal operation 0 to +40°CRel. humidity 30% to 75% *(<25g/m3)Limits of operation -5 to +45°CRel. humidity 5% to 95% *(<29g/m3)Storage and transport -40 to +70°CRel. humidity 95% at +45°C *(<35g/m3)* without condensationDimensions 224 × 160 × 44 mmWeight approx. 1.5 kg

Ordering information

EL409/E VDSL Copper QualifierELQ 30

Including

EL409/OMD Operating ManualShort form operation instructions

EL409/CC Calibration CertificateEL409/900 CD containing:

Read me fileOperating manual for ELQ 30Upgrade programDemo programPC programOperating manual for PC program (option)

EL107/421 Ground connecting cable (2 m)EL107/420 2 special balanced measuring cablesEL107/389 USB cableEL146/017 Mains adapter EL355/140A Battery (built-in) EL147/015 Carrying case

Options

PC software