2
Application Recommended for quick installation in small entries pipes and mixing tanks. Elixir caters to Brewery Distillery Dairy FMCG Packaging Utility Paper Sugar Power Paint Pharmaceuticals Bulk Drugs Chemicals Petrochemicals Pesticides Textile Food Cosmetics Confectionary Edible Oil Fast Commissioning Drift Free Operation No Moving Parts Easy Installation Reliable Switching No Wear & Tear PTFE & PFA lined available Microcontroller based Vibrating Fork Liquid Level Limit Switch True Universal Power Supply 11to 55 VDC 19 to 265 VDC } on same terminals Suitable up to 10,000 cP detects all industrial fluids Fluid Temperature Durability standard model up to 80°C H1 model up to 150°C H2 model up to 200°C Self Diagnosis system fault alarm fork erosion alarm Low Power Consumption - Less Heat - Long Life max 400 mili-watt Compact Size less inventory And... unaffected by fluid movements & gas bubbles independent of fluid electrical properties cover and uncover delay setting integral and remote versions adjustable insertion length X Salient Features Grown...to meet challenges Elixir

Elixir - SAPCON · Elixir liquid level limit switches are successfully used in processing plants for liquids having viscosity up to 10,000 cP and densities greater than or equal to

Embed Size (px)

Citation preview

Page 1: Elixir - SAPCON · Elixir liquid level limit switches are successfully used in processing plants for liquids having viscosity up to 10,000 cP and densities greater than or equal to

ApplicationRecommended for quick installation in small entries pipes and mixing tanks. Elixir caters to

BreweryDistilleryDairyFMCGPackagingUtilityPaperSugarPowerPaint

PharmaceuticalsBulk DrugsChemicalsPetrochemicalsPesticidesTextileFoodCosmeticsConfectionaryEdible Oil

Fast CommissioningDrift Free Operation

No Moving Parts Easy Installation Reliable Switching

No Wear & Tear

PTFE & PFA lined available

Microcontroller basedVibrating Fork Liquid Level Limit Switch

True Universal Power Supply11 to 55 VDC 19 to 265 VDC }on same terminals

Suitable up to 10,000 cPdetects all industrial fluids

Fluid Temperature Durabilitystandard model up to 80°CH1 model up to 150°CH2 model up to 200°C

Self Diagnosissystem fault alarmfork erosion alarm

Low Power Consumption - Less Heat - Long Life

max 400 mili-watt

Compact Sizeless inventory

And...unaffected by fluid movements & gas bubblesindependent of fluid electrical propertiescover and uncover delay settingintegral and remote versions adjustable insertion length

X

Salient Features

Grown...to meet challenges

Elixir

Page 2: Elixir - SAPCON · Elixir liquid level limit switches are successfully used in processing plants for liquids having viscosity up to 10,000 cP and densities greater than or equal to

System Diagram

Elixir S A W T S4 S

Probe Length in mmS 128mmE Extra

Wetted PartsS4 SS 304S6 SS 316SL SS 316 LHC Hastelloy C

Process ConnectionT Threaded: BSP/NPT/DIN 1’’F Flanged: ASA/ANSI/ JIS/DIN 1½”O Other (to be specified by customer)

EnclosureW Weather ProofP IP-65FLP Flame Proof for Gas Group IIa and IIb

Power & OutputA 19-260VAC, O/p SPDT Relay B 11-55VDC O/p SPDT RelayC 11-55VDC Open Collector PNPD Two-wire loop powered 8/16mA

TemperatureS Suitable up to 80 °CH1 Suitable up to 150 °CH2 Suitable up to 200 °C

Elixir

Order Code

PT PTFE linedPA PFA linedHL Halar lined

SpecificationsHousing

Type

Cable Entry

Mounting

Mains

Power Consumption

Output

Delay Setting

Sensing

Resonant Frequency

Extension

Material Temperature

Response Time

Switching Indication

Failsafe

Minimum Fluid Density

Maximum Fluid Viscosity

Switching Hysterisis

Dimensions

Cast aluminum Weather proof and Flame proof suitable for mounting in Hazardous area Gas Group IIA & IIB as per IS-2148

Integral with fork

Double Compression Gland

Screw : 1” to 1½” BSP/NPT(M)Flanged:(asperorder)Material: SS/MS(Plated)

19 to 260VAC 50/60Hz 11 to 55VDC

400 mili-Watt maximum

SPDT Potential-Free RelayContact 6A, 230VAC & 6A, 25VDC for non-Inductive loads.

Cover & Uncover Delay : 1 - 20 sec through DIP switches

Resonating Fork, SS-316

from 350Hz to 500Hz

Pipe - GI / SS

-20°C to 80°C/150°C/200°C

0.5 seconds

Bi-color LED, Red: Alarm, Green: Normal

Field Selectable (Min : Failsafe Low, Max : Failsafe High)

30.7 gm/cm

10,000 cP

5mm (approximately)

Refer Drawings/Customer Support

UsageElixir liquid level limit switches are successfully used in processing plants for liquids having viscosity up to 10,000 cP and densities greater than or equal to 0.7 gm/cc. As an sturdy replacement of conventional float switch, Elixir offers a variety of built-in features non-existant in floats and other switches, e.g. where materials are sticky, corrosive, agitated, splashing, foaming and having uncertain electrical properties.

Mains

External Load/Contactor*

Load/Contactor Supply*

Mains

External Load/Contactor*

Load/Contactor Supply*

Top Mounting with Extension

Side Mounting

* Load must match the output type