ELITE / ESPRIT Series
DS ELITEESPRIT-1
Features
• Very Long Range:
• LoRA Spread Spectrum,
• FM Technology
• 4 Channels Each Rated 1KW
• Relay Changeover Contacts
• Momentary or Latching or Timed
• Pair any Tx Switch to Any Rx O/P
• Power Supply either:
• 6-32Vdc/ac, 110Vac or 230Vac
• IP68 Waterproof Enclosure
• Signal Strength LED Indication
• Transmits RF Acknowledge signal
back to Transmitter
• Optional External Antenna mount
• Systems supplied ’ready to Go’
• Connections Via Screw Terminals
Applications
• Garden Lighting
• Pond pumps
• Remote outdoor Switching
• Industrial control
Compatible with All RF Solutions 868 / 918MHz Transmitters
Description
A versatile general purpose Remote Control System for many different applications.
Housed in a rugged IP68 enclosure, This receiver is ideally suited to any outside Remote
switching. It has 4 changeover relay outputs, using the ‘easy-learn’ process each output
can be controlled from one or many switches form one or many transmitters.
16KM Range Professional Receiver
Part No Description Supply Voltage
ELITE-8R4 Receiver 4 Channel 868MHz 230Vac or 6-32Vdc
ESPRIT-9R4 Receiver 4 Channel 918MHz 110Vac or 6-32Vdc
ESPRIT & ELITE Receivers
DS ELITEESPRIT-1 Page 2
Timer Erase Mode Pair
Supply
Either ac or dc
NOT Both!
~AC DC
Relaxed Active
NO COM NCNO COM NC
Relay OperationLink fitted - MOMENTARY
Link Removed - LATCHING
LED sPower
Transmit
Receive
RF Signal Strength LED Indication
Relay
Configuring the Receiver
Relay Outputs Each output relay is an independent isolated
switch. capable of switching 1KW
(5A @ 230V).
Fuse Rating 4A
ESPRIT & ELITE Receivers
DS ELITEESPRIT-1 Page 3
Timer Erase Mode Pair
Supply
Either ac or dc
NOT Both!
~AC DC
Relaxed Active
NO COM NCNO COM NC
Relay OperationLink fitted - MOMENTARY
Link Removed - LATCHING
LED sPower
Transmit
Receive
RF Signal Strength LED Indication
Relay
AUTO PAIR a new transmitter (PAIR complete Transmitter to complete Receiver)
1. Press PAIR button for >1sec then release
2. All relay LEDs Flash at a high rate
3. Press ANY button on the transmitter.
4. All LEDs will go out,
5. Wait 3 secs to confirm
NOTE: Maximum 128 Transmitters can be Paired.
MANUAL PAIR a new Transmitter (PAIR individual Relay output to individual transmitter
switch)
1. Press PAIR button for >1sec then release
2. Repeat Press the PAIR button until the chosen
Relay LED is flashing
3. Briefly Press the SPECIFIC transmitter Switch
you wish to PAIR with this Relay output.
4. PAIR LED will flash quickly for 2 seconds to con-
firm.
NOTE: Maximum of 128 SWITCHES can be paired
You cannot mix Auto PAIR and Manual PAIR!
ERASE ALL transmitters: 1. Press and hold the ERASE button for 10 seconds
2. All relay LEDs flash together and then go out
3. Erase complete
ERASE Individual Transmitters: 1. Press and release the ERASE button
2. The ERASE LED flashes and all relay LEDs will be
flashing
3. Press Switch on the transmitter to be erased
4. When all output LEDs go out transmitter is
erased
Timer (Setting a Timed Output)
1. Repeat press the TIMER Switch to scroll
through output relays until the chosen relay
LED is flashing.
2. Wait for LED to be on constantly.
3. Now Each press of the timer button will in-
crease the timer delay in line with the TIMER
OUTPUT Table (see next page).
4. When you have selected the required delay, wait
3 seconds.
5. The Red TIMER LED will Stop flashing to show
that the setting is saved
Note: Settings are saved even if power is cycled.
Note: When zero LED’s are lit the relays will oper-ate as per the Momentary/Latching links
To Erase ALL Timers: 1. Press and hold TIMER button for 10 seconds,
2. When the LED flashes fast release the timer
button the erase is complete
Mode (RF Mode of Operation) 1. Repeat press the MODE Switch to scroll
through Sig Strength LEDs until the chosen
LED/Mode of operation LED is selected. - See
Separate Table
2. Wait 3secs to confirm.
ESPRIT & ELITE Receivers
DS ELITEESPRIT-1 Page 4
TIMER (Setting an Output Time Delay)
Mode of Operation This Receiver can be configured to operate in FSK or LoRA Modes.
FSK = (FM) fixed frequency Carrier Frequency. Provides a fast Time of operation and is compatible with all other RF Solutions products at this frequency.
LoRA– Long Range Spread Spectrum .
Modes 1-7 operation where the operating Range is extended but so also is the time delay from
transmitter operation to Receiver Relay activation.
LED Mode Typical RF Transmit
8 LORA 7 1.28 Seconds
7 LORA 6 640 mSecs
6 LORA 5 320 mSecs
5 LORA 4 160 mSecs
4 LORA 3 80 mSecs
3 LORA 2 40 mSecs
2 LORA 1 20 mSecs
1* FSK 20 mSecs
To Set the Mode of operation
1. Press the MODE button momentarily the MODE
LED will flash.
2. Repeat press the MODE button until the chosen
LED / Mode is selected
LED Output Time
8 60 mins
7 30 mins
6 10 mins
5 1 mins
4 30 Secs
3 10 Secs
2 5 Secs
1 1/2 Sec
0 Momentary
*This is Factory Default
ESPRIT & ELITE Receivers
DS ELITEESPRIT-1 Page 5
Connecting an External Antenna
An External Antenna connection maybe con-
nected into the UFL connector.
A direct UFL plug in coax Cable is available to
which provides Standard SMA panel mount type
connector onto which many external antenna
can connect
Antenna : ANT-GSM5WM
• Wall mount antenna
• 3m cable
• Wall Mount Whip Antenna
• Active gain: +5dB
• RG58 Connecting Lead
• SMA Connector
CBA-UFLSMA
Push fits onto the UFL Connector and provides a
panel mount SMA connector which can be mounted
in the enclosure.
Antenna : ANT-PUKDB
• Rugged “PUCK” Screw Fix Mount
• +2dBi Gain
• Omni directional Antenna
• 1.5metres RG174 Cable
• SMA Male Connector
• M14 Screw Fix connector
UFL
Connector
ESPRIT & ELITE Receivers
DS ELITEESPRIT-1 Page 6
251.00
All Dimensions in mm
10
6.0
0
53
.00
125.50
Wall Mounting template (not to scale)
RELAY 1 RELAY 3 RELAY 4
FUSE
L N E
0Vdc
12-3
2Vac/d
c
NO COM NC NO COM NC NO COM NC NO COM NC
230V INPUT
SUPPLY
Application Drawing - Switching a Lamp
ESPRIT & ELITE Receivers
Disclaimer:
Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or
completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make
changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or
products for their own particular requirements or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of
how to deploy or use R F Solutions Ltd’s products. Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with ex-
press written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or
caused by reliance on the information contained herein or from the use of the product (including liability resulting from
negligence or where RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd’s liability
for death or
personal injury resulting from its negligence.
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2011/65/EU
Specifies certain limits for hazardous substances.
WEEE Directive 2012/19/EU
Waste electrical & electronic equipment. This product must be disposed of
through a licensed WEEE collection point. RF Solutions Ltd., fulfils its WEEE
obligations by membership of an approved compliance scheme, environment
agency registration number WEE/JB0104WV.
Waste Batteries and Accumulators
Directive 2006/66/EC
Where batteries are fitted, before recycling the
product, the batteries must be removed and
disposed of at a licensed collection point.
Environment Agency producer registration num-
ber: WEE/JB0104WV.
Important European compliance information
This RF Solutions product meets the essential requirements of the European Radio Equipment Directive
2014/53/EU and has been tested to European Harmonised Standards and CE marked accordingly. A copy of the
EU Declaration of Conformity can be located on the RF Solutions Website, www.rfsolutions.co.uk/certification-
Technical specifications
Enclosure Rating: IP68
Dimensions: 267 x 148 x 78mm (not including antenna)
Operating Temperature: -10 to +60o Celsius.
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
Electrical Characteristics MIN TYPICAL MAX DIMENSION
Supply Voltage 6 32 Vdc or ac
Operating Frequency
868MHz Version
918MHz Version
869.5
918.0
MHz
Supply Voltage for ac
ESPRIT
ELITE
110
230
Vac
Relay Rating* (230Vac) 5 12 A
Supply Current at Vsupply
Quiescent
All relays operating*
17
175
mA
Time from Tx on Switch to Rx Relay operation (FM) 30 mS
Time from Tx sw relax to Rx Relay release 30 mS
http://www.rfsolutions.co.uk/certification-i59