24
Electricity Meters

Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

Ele

ctri

city

Me

ters

Page 2: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr
Page 3: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

Getting started;

ELEKTROMED electronic meters are manufactured in Turkey with 20 years of experience. All the design and manufacturing stages are performed hundred percent in own factories.

ELEKTROMED has products for household, commercial, lightning, industrial and energy distribution lines. From residential type single-phase meter to distribution point meters with external current and voltage transformers, ELEKTROMED has all the meter models which distribution companies require.

ELEKTROMED meters are manufactured and sealed according to Europe wide valid Measurement Instrument Directive (MID) regulations and ready for service.

ELEKTROMED is constantly designing and developing new and economical solutions with strong R&D Department and modern production technology.

1

ww

w.e

lekt

rom

ed

.co

m.tr

Page 4: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

• Easy Installation and Stylish Industrial Design

ELEKTROMED electricity meters have small and aesthetic design which can easily be replaced with mechanical meters uninstalled from site. Industrial design is performed by taking long term high performance usage, easy installation, usage and future-proof properties into consideration.

• Accurate Metering

ELEKTROMED meters have electronic metering (solid state) structure which enables long term accurate metering service life. Self consumption is lower than standard values and all the components are selected and tested carefully. Reference and base current values are assigned as 5 A to increase the accuracy.

ELEKTROMED meters perform measurement accurately from starting current up to 100 A on direct connection mode, up ot 10 A on current transformer connection mode because dynamic range of metering circuits are wide. Even the current ends are connected reversely, metering accuracy will stay in the same range and consumption will be recorded as its absolute value.

• Custom Display Design

Meter display specially designed large for comfortable reading. Display messages are supported by symbols for better understanding. Backlight is standard for active-reactive meters and optional for residential meters.

• Remote reading

In the near future all meters will be read remotely. For remote reading, meters shall be equipped with communication module. Most common and economical of these module is RS485. For this reason, active-reactive meters held by high consuming customers and have RS485 output as a standart feature. Forresidential single phase and three phase meter have RS485 module as option.

• Environmental Friendly

Elektromed have ISO9001 and ISO18001 certificates from design to production, marketting to sales processes.

All the precautions for protecting and improving the environment are taken and been applied. From battery decision to package design, and all stages this precision is applied. ELEKTROMED proved this structure by ISO 140001 Environment Management System certificate.

2

ww

w.e

lekt

rom

ed

.co

m.tr

Page 5: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

co

nte

nt

EC0 & EC1 SERIES• EC058• EC15A• EC15X

EC25 SERIES• EC25TP• EC25TC• EC25TV

A SERIES• A0H• A5• A6

Page 6: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

4

ww

w.e

lekt

rom

ed

.co

m.tr

Features• MID certified• Confirm to IEC 50470-1/3 standards • Class B (±1%) active energy metering accuracy• UV protection, polycarbonate IP54 body• Wide working range 150V - 320V Maximum 100A for EC1, maximum 80A for EC0 Outdoor, -40 C .. +70C IP54 protection degree• 4 tariffs, 8 time slices, 3 day type, TOU• 0.5 sec/day real time clock accuracy• Automatic Daylight Saving Application (DST)• Optical port (EN62056-21/61)• Index reading from display during absence of power• Data reading from optical port during absence of power• Custom LCD design• Ergonomic and light weight body• 10 years of battery life

Innovations• 5A basic current• Backlight display• 30 day / 30 min load profile• Monthly demand monitoring• Current and voltage monitoring

Protection Features• Terminal cover open tamper detection• Top cover open tamper detection• Independent terminal and body cover sealing• Password protection for programming mode• Absolute energy value recording when reverse connected• Protection against memory manipulation• Previous months’ values• Last 12 months tariff consumption recording

System Solutions• Optical port conformity to IEC standards• RS485 port (optional)• Optional MODBUS support• Optional DLMS/COSEM support

EC0 & EC1 SERIESRESIDENTIAL TYPE ELECTRICITY METERS

Page 7: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

5

ww

w.e

lekt

rom

ed

.co

m.tr

EC058Single Phase Electricity Meter

Specially Designed Small and Light Structure for Residential Type Applications

Connection Type 1 phase 2 wireTechnical Specifications Parameters

Terminal Connection DIN / BSAccuracy Class Class B (TS EN 50470-1/3) (±1%)Application Voltage Range -20% .. +15% Un (Un = 230 V)Frequency 50 HzMeter Constant 1000 imp/kWhBase Current, Iref 5 A, 10 AMaximum Current, Imax 80 A or ≥ 5 x IrefStarting Current, Ist 20 mADisplay LCD 8 digit + symbolsOptical Port Read/Write (TS EN 62056-21)Weight 0.5 kg

Model B C D 155 58 40

A101EC058MBW

Terminal Connection Diagram Model

C

D

LN

LN

LL

NN

(DIN) (BS)

Page 8: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

6

ww

w.e

lekt

rom

ed

.co

m.tr

Connection Type 3 phase 4 wireTerminal Connection DINAccuracy Class Class B (TS EN 50470-1/3)Aplicattion Voltage Range -20% .. +15% Un (Un = 3x230/420V)Frequency 50 HzMeter Constant 1000 imp/kWhBase Current,Imax 5 A, 10 AMaksimum Akım, Imax 100 A or ≥ 5 x IrefStarting Current, Ist 20 mADisplay LCD 9 digit + symbolsOptical Port Read/Write (TS EN 62056-21)Weight 0.8 kg

Technical Specifications Parameters

EC15AThree Phase Electricity MeterSpecially Designed Small and Light Structure for Residential Type Applications

Model B C D230 67 51

A160EC15ATBW

A

B

C

D

Terminal Connection Diagram Model

Page 9: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

7

ww

w.e

lekt

rom

ed

.co

m.tr

EC15X Three Phase Electricity Meter with

External Current Transformer ConnectionThree Phase Electricity Meter with External Current Transformer Connection

Model B C D 230 67 51

A160EC15XTBW

Technical Specifications ParametersConnection Type 3 phase 4 wireTerminal Connection DINAccuracy Class Class B (TS EN 50470-1/3)Aplicattion Voltage Range -20% .. +15% Un (Un = 3x230/420V)Frequency 50 HzMeter Constant 2000 imp/kWhNominal Current, In 5 AMaximum Current, Imax 6 AStarting Current, Ist 15 mADisplay LCD 9 digit + symbolsOptical Port Read/Write (TS EN 62056-21)Weight 0.8 kg

L1L2L3N

L1L2L3N

A

B

C

D

Terminal Connection Diagram Model

Page 10: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

8

ww

w.e

lekt

rom

ed

.co

m.tr

EC25 SERIESTHREE PHASE ACTIVE-REACTIVE ELECTRICITY METERS

Features• MID certified• Conformity to IEC 50470-1/3 stadards • Class B (±1%) active energy metering accuracy• UV protection, polycarbonate IP54 body• Wide working range 40V - 320V Maximum 100A Outdoor, -40C .. +70C IP54 protection degree• 4 tariffs, 8 time slices, 3 day type, TOU• Demand reset button• 0.5 sec/day real time clock accuracy• Automatic Daylight Saving Application (DST)• Index reading from display during absence of power• Data reading from optical port during absence of power• Custom LCD design• Ergonomic and light weight body• 10 years of battery life

Load Profile • 15, 30, 60 min adjustable periods• 3 channel active, inductive and capacitive reactive energy• Total 5832 registers till 8 months

Event registers• 10 records for R,S,T Phase power down • 10 records for electricity power down• 10 records for R,S,T current reverse connection• 10 records for phase sequence errors• 12 records for terminal cover open and quantity• Top cover open

System Solutions• Optical Port (IEC62056-21)• RS485 port (IEC62056-21)• Optional isolated pulse output• Optional MODBUS support• Optional DLMS/COSEM support

Protection Features• Terminal cover open warning notification and record• Top cover open warning notification and record• Independent sealing for terminal and top cover • Demand reset button• Password protected programming mode•Absolute energy value recording on reverse connection• External memory data write protection• Previous months maximum demand values• Last 24 months tariff consumption records • Phase sequence error notification and register• Reverse current connection notification and register

Page 11: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

• If the real time clock is in error mode symbol flashes instead of tariff obis codes.

Obis Code Table

LCD Warning Symbols

Technical Specifications ParametersConnection Type 3 phase 4 wireTerminal Connection DINAccuracy Class - active Class B or CAccuracy Class - reactive Class 2Frequency 50 HzProtection Class IP54Electromagnetic Environmental Class E2Mechanical Environmental Class M2Temperature Range -40...+70 ˚CCurrent Circuit Power Consumption < 2W, 10VAVoltage Circuit Power Consumption < 4VADisplay LCD 9 digit + SymbolsDemand Time Interval Load Profile Cumulative Consumption Values (1.8.0, 5.8.0 ve 8.8.0)Load Profile Period Optical Port Mode C Readout, 9600baud (IEC62056-21)Pulse Output 1pulse / WhRS485 Port 2500 V isolation Voltage, Mode C Readout, 9600baud (IEC62056-21)

Obis Code Description0.0.0 Serial Number0.9.1 Meter Time0.9.2 Meter Date0.9.5 Day of Week1.8.0 Cumulative Active Energy ( Import )

1.8.1 Total Energy T11.8.2 Total Energy T21.8.3 Total Energy T31.8.4 Total Energy T41.6.0 Maximum Active Power1.6.0*1 Previous Month Maximum Active Power

Obis Code Description96.71 Last Terminal Cover Open Date96.70 Top Cover Open Date1.8.1*1 T1 Month Starting Consumption Value1.8.2*1 T2 Month Starting Consumption Value1.8.3*1 T3 Month Starting Consumption Value1.8.4*1 T4 Month Starting Consumption Value5.8.0 Reactive Inductive Energy Consumption 8.8.0 Reactive Capacitive Energy Consumption 5.8.0*1 Reactive Inductive Month Starting Value 8.8.0*1 Reactive Capacitive Month Starting Dates 0.1.0 Demand Reset Count

0.1.2*1 Last Demand Reset Date and Time

9

ww

w.e

lekt

rom

ed

.co

m.tr

• Terminal cover open warning.• Top cover open warning.

15 (default), 30 or 60 dk

30 (default), 15 or 60 dk

• Shows that all phases are active.• If any of the phases power down, related phase icon disappears.• If any two of the phases are reverse con-nected, it shows the reverse connected phase symbols.• While meter measures active consumption in correct direction, quadrant is shown with correct arrow direction

• If the current is reverse connected, quadrant flashes the arrow direction and instead of tariff OBIS codes, related phase symbols gjcb flash with (Reverse) symbols

Page 12: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

10

ww

w.e

lekt

rom

ed

.co

m.tr

Technical Specifications ParametersVoltage 3x230 / 400VMeter Constant 1000 imp / kWh, 1000 imp / kVArhStarting Current, Ist 20 mAMinimum Current Imin 250 mAReference Current, Iref 5 AMaximum Current, Imax 100 AWeight 1.2 kg

Model B C D 230 73 51

A160EC25TPA3CHB

EC25TPDirect Connected Three Phase Electricity MeterThree Phase Electricity Meter with Active-Reactive Power Measurement

8.8.0 Reactive Capacitive Energy Consumption

1 3 4 6 7 9 10 12

L1L2L3N

L1L2L3N

D

C

B

A

Terminal Connection Diagram Model

Page 13: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

11

ww

w.e

lekt

rom

ed

.co

m.tr

Technical Specifications ParametersVoltage 3x230 / 400 VMeter Constant 10000 imp / kWh, 10000 imp / kVArhStarting Current, Ist 10 mAMinimum Current, Imin 50 mANominal Current, In 5 AMaximum Current, Imax 10 AWeight 1.0 kg

Model B C D 230 73 51

A160EC25TC13CHB

EC25TCEC25TC External Current Transformer Connected

Active-Reactive Electricity MeterThree Phase Electricity Meter with Active-Reactive Power Measurement

for High Consuming Commercial Customers

8.8.0 Reactive Capacitive Energy Consumption

L1L2L3N

L1L2L3N

D

C

B

A

Terminal Connection Diagram Model

Page 14: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

12

ww

w.e

lekt

rom

ed

.co

m.tr

Technical Specifications ParametersVoltage 3x57,7 / 100VMeter Constant 10000 imp / kWh, 10000 imp / kVArhStarting Current, Ist 10 mAMinimum Current, Imin 50 mANominal Current, In 5 AMaximum Current, Imax 10 AWeight 1.0 kg

Model B C D 230 73 51

A160EC25TV13CHB

EC25TVExternal Current and Voltage TransformerActive-Reactive Electricity MeterThree Phase Electricity Meter with Active-Reactive Power Measurement for Energy Distribution Lines

D

C

B

A

L1

N

X

U

1 3 4 6 7 9 11852

k l

K L K L K L

k l k l

U U

U U U

X X

X X X

L2

L3

L1

L2

L3

Terminal Connection Diagram Model

Page 15: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

13

ww

w.e

lekt

rom

ed

.co

m.tr

Features• MID certified• Class B (±1%) active energy metering accuracy• UV protected, policarbonate IP54 body• Wide working range 150V - 320V Maximum 100A Outdoor, -40C .. +70C IP54 protection degree• 4 tariffs, 8 time slices, 3 day type, TOU• Demand reset button• 0.5 sec/day real time clock accuracy• Automatic Daylight Saving Application (DST)• Index reading from display during absence of power• Data reading from optical port during absence of power• Custom LCD design• Ergonomic and light weight body • 10 years of battery life

Internal Turn On-Off Relay• Integrated latched relay• 100A maximum current• 20ms operation time• Conformity to IEC 62054-11 requirements

System Solutions• Smart card with ISO 78186 standard • Optical port conformity to IEC standards• RS485 port (optional)• MODBUS protocol (optional)

Protection Features• Secure IC card application• Previous month consumptions and meter status information carried by card• Terminal cover open detection• Top cover open detection• Independent sealing for terminal and top cover • Absolute energy value recording on reverse connection mode.• External memory data write protection

A SERIESELECTRICITY METERS WITH PREPAYMENT / INTEGRATED RELAY

Page 16: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

L L

N N

Terminal Connection Diagram Model

14

ww

w.e

lekt

rom

ed

.co

m.tr

Technical Specifications ParametersRated Voltage 240Voltage Variation -30, +20Frequency 50 (% 5)Base Current 5, 10Maximum Current 30Accuracy Class (ICE 62052-11) Class 1AC Withstand Voltage 440 (Minimum 5 minutes)Impulse Withstand Voltage 6000

RS485 (Optional)Automatic Meter Reading SystemDisplay Backlit LCDInterface Unit Optical Port (IEC 62056-21)Number of Tariff Periods 6Time Deviation (IEC 61038)

Backup Unit

Degree of ProtectionReferans StandartReference Standards

EEPROM Nonvolatile MemoryCommunication Interface

IP 54 Outdoor (IEC 620529)IEC 62053-21, IEC 62052-11

IEC 62056-21/61>20

DLMS (Optional), IEC 62056

- Shelf Life- Operation Life

Lithium Battery (LiSO2CI)10 years4 years

0.5

A0HActive Single Phase Electricity Meter

Model B C D E 193 73 88 115

A118A5

CA

BE

F

+_

+_

LL

NN

Page 17: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

In electrical engineering, single phase electric power refers to the distribution of alternating currentelectric power using a system in which all the voltages of the supply vary in unison. Single phase powerdistribution is widely used especially in rural areas.

Elektromed A0H series single phase electricity meters combines unique features in one product. These meters provide high protection against energy theft. With DLMS/COSEM feature which is the common language so that the partners can understand each other, meter is capable for;

• The standardised interface classes and data types; • The object identification system, providing a standar identifier for each and every object; • The possibility to retrieve the resources available in the metering equipment by reading the COSEM association objects.

Basic Features

• Compliant with IEC 62056 • Energy measurement; able to measure both forward and reverse energy. For both conditions consumed energy can be written in a single register (optional) • High protection; able to detect 31 different tamper conditions including neutral missing and neutral disturbance conditions • External AC and DC magnetic field detection Accurate measurement on 0,2 Tesla AC magnetic field Accurate measurement on 0,5 Tesla DC magnetic field • Durablity aganist 35 kV statical voltage discharge • Backlite LCD • Transreceiving data via optical port • Real time clock

15

ww

w.e

lekt

rom

ed

.co

m.tr

T6REVERSE

DLMS

kWhN S

DATA

!

TARIFF6 programmable tariffs

BATTERYBattery level

WARNING (Optional)Terminal cover opening

DLMS (Optional)Communication protocol

kWhActive energy measurement

RESERVEReserve energy flow

EARTHINGEarthing detection

MAGNETIC DETECTIONExternal magnetic field detection

DATA TRANSFER (Optional)AMR applications

Page 18: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

16

ww

w.e

lekt

rom

ed

.co

m.tr

TAMPER CONDITIONS

4. CONDITION

PHASE AND NEUTRALCURRENT REVERSED

ETF

LI NI NO LO

REV

LOADLN

3. CONDITION

ETF

LI NI NO LO

REV

LOADNL

FULL LOAD EARTH RETURNED

ETF

LI NI NO LO

REV

LOADLN

5. CONDITION

ETF

LI NI NO LO

REV

6. CONDITIONLOAD

N

L

FULL LOADEARTH RETURNED ANDCURRENT REVERSED

ETF

LI NI NO LO

REV

7. CONDITION

ETF

LI NI NO LO

REV

8. CONDITION

LOADLN

LOAD

NL

1. CONDITION

ETF

LI NI NO

REV

LOADL

N

LO

ETF

LI NI NO LO

REV

LOADNL

2. CONDITION

NORMAL WIRINGNOT TAMPERED

LINE-NEUTRAL NORMAL CONNECTED LINE-NEUTRAL REVERSE CONNECTED

PARTIAL LOADEARTH RETURNED

ETF

LI NI NO LO

REV

LOADL

N

9. CONDITION

ETF

LI NI NO LO

REV

LOAD

NL

10. CONDITION

LOAD

ETF

LI NI NO LO

REV

11. CONDITION

ETF

LI NI NO LO

REV

12. CONDITION

LOAD

LN

LOAD

NL

PARTIAL LOADEARTH RETURNED ANDCURRENT REVERSE

LI: LINE INPUT NI: NEUTRAL INPUT

NO: NEUTRAL OUTPUTLO: LINE OUTPUT

ETF: EARTHING INDICATOR

REV: REVERSE INDICATOR

Page 19: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

21. CONDITION

ETF

LI NI NO LO

REV

CURRENT BY-PASSED

LINE-NEUTRAL NORMAL CONNECTED LINE-NEUTRAL REVERSE CONNECTED

17

ww

w.e

lekt

rom

ed

.co

m.tr

LI: LINE INPUT NI: NEUTRAL INPUT

NO: NEUTRAL OUTPUTLO: LINE OUTPUT

ETF: EARTHING INDICATOR

REV: REVERSE INDICATOR

ETF

LI NI NO LO

REV

LOADL

N

13. CONDITION

ETF

LI NI NO LO

REV

14. CONDITION

NEUTRAL CURRENT REVERSED

LOADN

L

ETF

LI NI NO LO

REV

15. CONDITION

ETF

LI NI NO LO

REV

16. CONDITION

PHASE CURRENT REVERSED

LOADL

N

LOADN

L

ETF

LI NI LI NINO LO

REV

LOADL

N

17. CONDITION

ETF

NO LO

REV

18. CONDITION

PARTIAL LOADEARTH RETURNED ANDNEUTRAL CURRENT REVERSED

LOADN

L

ETF

LI LINI NO LO

REV

19. CONDITION

ETF

NI NO LO

REV

20. CONDITION

PARTIAL LOADEARTH RETURNED ANDPHASE CURRENT REVERSED

LOADL

N

LOADN

L

Page 20: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

18

ww

w.e

lekt

rom

ed

.co

m.tr

Technical Specifications ParametersConnection Type 1 phase 2 wireTerminal Connection DIN / BS Accuracy Class Class B (TS EN 50470-1/3)Aplication Voltage Range -20% .. +15% Un (Un = 230 V)Frequency 50 HzMeter Constant 1000 imp / kWhBase Current, Iref 5 A, 10 AMaximum Current, Imax 60 A or ≥ 5 x IrefStarting Current, Ist 20 mADisplay AlphanumericalOptical Port Read/Write (TS EN 62056-21)Weight 0,72 kg

A5Single Phase Electricity MeterResidential Type Prepayment and Remote Open Close Applications

Model B C D 193 73 75

A118A5

L N

L N

L L

N N

A C

B

D

Terminal Connection Diagram Model

(DIN) (BS)

Page 21: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

19

ww

w.e

lekt

rom

ed

.co

m.tr

ParametersConnection Type 3 phase 4 wireTerminal Connection DINAccuracy Class Class B (TS EN 50470-1/3)Aplication Voltage Range -20% .. +15% Un (Un =3x230/420V)Frequency 50 HzMeter Constant 500 imp / kWhTemel Akım, Iref 5 A, 10 AMaximum Current, Imax 100 A or ≥ 5 x IrefStarting Current, Ist 20 mADisplay AlphanumericalOptical Port Read/Write (TS EN 62056-21)Weight 1.0 kg

A6Three Phase Electricity Meter

Residential and Commercial Type Prepayment and Remote Open-Close Applications

Model B C D 245 87 178

A154A6

A C

B

D

Terminal Connection Diagram Model

Page 22: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

METER READING PROGRAM

ELEKTROMED developed a software that reads data from meters and convert these data to meaningful tables.Clients may download this packet program free of charge at website.

Information grouped by program in table format:

• Readout Reading• Last 12 Months Consumption Values• Last 6 Months Demand Information• Cover Open Date • Connection Error Evet Logs• Phase Power Down Event Logs• Load Profile (Between Two Dates )

20

ww

w.e

lekt

rom

ed

.co

m.tr

Page 23: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr
Page 24: Elektrik Sayaçları Dergisi İngilizce · • Optional MODBUS support • Optional DLMS/COSEM support EC0 & EC1 SERIES RESIDENTIAL TYPE ELECTRICITY METERS. 5 www. elektromed.com.tr

www.elektromed.com.tr

www.elektromed.com.trOrganize Sanayi Bolgesi Uygurlar Cd.

No:4 06935 Sincan / ANKARA / TURKEY

T: (+90 312) 267 13 67 (pbx)

F: (+90 312) 267 13 66