Electronics INFO

Embed Size (px)

Citation preview

  • 8/7/2019 Electronics INFO

    1/4

    1. Huntron tracker alternate mode

    2. Chop mode high frequency sampling and display

    3. 5% - typical accuracy for time based measurements

    4. 7% - typical accuracy maximum magnification

    5. 5% of vertical trace - typical width of trace in oscilloscope6. 3% - volt per division

    7. 1Mohm with 30pf capacitance input of oscilloscope

    8. Multiple function generator used to display intermodulation distortion

    9. 50 500 v range of breakover voltage for scr

    10. 30 100 A - range of forward current for scr

    11. Germanium dioxide used for commercial germanium diodes

    12. Curve tracer commercial available tracer

    13. 1 um accuracy of visual proximity sensor

    14. Photodetector heart of all photo sensor15. Squid used in MEG(magnetoencephalography)

    16. Jones circuit uses scr for triggering dc motor

    17. 1934 zener diode was developed

    18. 1958 esaki diode was developed

    19. Actuating signal difference between reference signal and feedback signal

    20. Germanium used as cryogenic thermistor

    21. LED has a disadvantage of wider spectral width

    22. 2 to 3 times injection laser diode is brighter than led by _______

    23. Childs law variation of voltage and current values24. Rodney brooks famous for his insect robots

    25. Boole first to use mathematical analysis in logic circuits

    26. TTL has larger input current compared to DTL

    27. RTL is slow because of its input base resistance and transistor

    capacitance

    28. RCTL faster version of RTL

    29. 10khz 75khz frequency range of ultrasonic welding

    30. 450khz high frequency welding

    31. Cold welding pressure welding32. Friction welding solid state welding

    33. Diffused junction used in solar cells

    34. Alloy junction used in high power transistor and simple to make

    35. MESA transistor has a disadvantage of having collector resistance

    36. Series field resistance winding causes an increase in speed of dc motor

  • 8/7/2019 Electronics INFO

    2/4

    37. Series resistance with the armature limits the starting current of dc motor

    38. Diode conducts in only one direction

    39. A1,A2,A3 also called electron lens

    40. A2 - also called focus ring, has potential of -2kV

    41. Beam finder - shifted beam42. Vertical A and B oscilloscope that show 2 displays

    43. MosFET conduction graph is parabolic

    44. Chain drive constant gear

    45. Expert system a rule based system

    46. For every 10 deg. C increase in temp saturation current doubles

    (100% increase)

    47. For every 1 deg. C increase in temp saturation current increases 7%

    48. 12kV potential of helix in oscilloscope

    49. 10V turning off voltage of HDL50. 1.1 eV energy gap for silicon

    51. 58 62 Hz vibrating reed

    52. 0.5MHz - 3GHz range of frequency meter

    53. 10^9 switching speed of SCR

    54. Tunnel diode no isolation

    55. Average current decreases when the firing angle is increased in an SCR

    56. Speed increases when the firing angle is increased in an SCR

    57. Motor is jogged when applied with short burst of current/voltage

    58. Voltage shunt voltage source employed in OP-AMPS59. Class A uses transformer coupling

    60. Impedance coupling used in high frequency

    61. RC coupling for multiple networks

    62. Sample and hold circuit used in constant gain non-inverting op-amp

    63. ICBO most important parameter

    64. Diode normal operating condition VBE = 0.7v , VCB = 0.2v

    65. Wien bridge measures capacitance and losses

    66. Vacuum tube used in grid dip meter (tandaan vacuum tubes lng ang my

    grid whether triode, tetrode etc)67. Water used in 1GHz flow calorimeter

    68. Squirrel cage motor has low starting torque

    69. Series motor universal motor

    70. Digital computer pulsed counting accelerometer

    71. Accelerometer is based on inertia

  • 8/7/2019 Electronics INFO

    3/4

    72. Screening mammogram used for breast scanning

    73. 1 CE and CB cascade configuration

    74. Examples of gas discharge tube include neon and fluorescent

    75. External current limiter protection on gas discharge tube

    76. HTL fastest unsaturated77. ECL fastest saturated

    78. RTL first to be implemented in logic gate (1960)

    79. 2 comparators used in 3 bit ADC

    80. Fibrous braid most commonly used wire protection

    81. Earth fault leakage current from center of wire to earth

    82. Blavier test for single wire cable

    83. Steering the solder while soldering prevents sweat joint

    84. Quarter adder without carry

    85. 2 halfwave rectifier used as voltage doubler86. 1 10 H range of power supply choke

    87. Eutectic alloy no semiliquid phase

    88. Application of positive feedback narrowband amplifier, oscillator, radio

    receiver

    89. Rosin flux used in electronic circuits

    90. +/- 50 to +/- 500 mV range of small signal sensor

    91. Moving coil instrument even scale in measuring dc

    92. Moving coil rectifier instrument even scale in measuring ac

    93. Moving iron instrument uneven scale in measuring ac/dc94. Moving magnet instrument uneven scale in measuring dc

    95. Moving magnet rectifier instrument uneven scale in measuring ac

    96. 22% - max efficiency of solar panel

    97. Walkthrough programming used by playback robot

    98. Solar panel has lower resistance compared to photodiode

    99. Potentiometer used in comparing voltages

    100. Potentiometer used as position sensor in servo system

    101. AC servomotor easy to manufacture at high torque

    102. QRIO Sony robot103. Relay used to decrease current in circuit

    104. Air gap in magnetic circuit increases reluctance

    105. Maximum power transfer occurs when load equals input impedance of

    generator

    106. Diode is unidirectional and unilateral

  • 8/7/2019 Electronics INFO

    4/4

    107. Transistor will be unstable due to temperature variation and parameter

    variation

    108. Nyquist plot - steady state frequency analysis

    109. Negative bias the gain is proportional to the decrease in output

    impedance110. 10:1 attenuation of 10 fold probe

    111. Unbiased pn junction has contact potential

    112. Commutator used to generate dc voltage

    113. SMAW (shielded metal arc welding) uses the tip of electrode that is

    melting

    114. Slip speed synchro rotor speed

    115. Clinometer measure slope

    116. Thermal stability advantage of UJT vs FET

    117. Varley loop test measure fault in telephone cable118. De sautys bridge measures capacitance based on known capacitance

    119. Autonomous robot works independent

    120. Cray 1 supercomputer using gallium arsenide (invented by Seymour

    Cray)

    121. Android is best use in environment with children

    122. Triac is used in colored TV

    123. Bistable uses 2 nand gates

    124. Manipulator robot arm

    125. High level language source program126. Biometry is used for identification, verification and authorization

    127. Core loss eddy current and hysteresis loss

    128. Zinc cathode of a dry cell

    129. Greater accuracy advantage of multispeed over single speed synchro

    130. FLOPS (floating operations per second) measure of processing speed of

    supercomputer

    131. Mossbauer effect refers to condition where nucleus is stimulated to emit

    very sharply defined beams of gamma rays

    132. Power loss copper loss133. When motor is overloaded it will overheat

    134. The speed of a three phase motor can be increased by decreasing the

    external resistance in the rotor circuit

    135. Microelectronics general term for miniature electronics