Upload
jacques-charlier
View
74
Download
8
Tags:
Embed Size (px)
DESCRIPTION
électrodes for ERG (electroretinography)
Citation preview
ELECTRODESHCATALOGUE
METROVISIONH4HrueHdesHPlatanesH5984fHPERENCHIESHFRANCETelH:H@33H3HcfHw7Hw9H57HHFaxH:H@33H3HcfHw7Hw9H5wHHexport@metrovisionifrHHwwwimetrovisionicom
METROVISION+c+6+rue+des+Platanes+U?h6L+PERENCHIES+++FRANCETelb+iKK+K+DL+GW+G?+UW+++Faxb+iKK+K+DL+GW+G?+UG+++@b+export@metrovisionwcom+++wwwwmetrovisionwcom
TABLE+OF+CONTENTSTABLE+OF+CONTENTS
GENERAL+INFORMATIONLGw
SCLERAL+LENSES+FOR+ERGLDw
NON+CORNEAL+ELECTRODES+FOR+ERGLKw
NEEDLE+ELECTRODESL6w
SKIN+CONTACT+ELECTRODESLUw
CABLESLfw
CONDUCTIVE+PASTELWw
SPARE+PARTSLhw
THE+VISION+MONITOR+IN+DLGUL?w
EC+CertificationPrice+conditionsWhich+electrodes+to+chooseyWhich+connector+to+chooseyWhich+electrode+paste+to+usey
................................................................................... 03................................................................................. 03
............................................................ 03.............................................................. 04........................................................... 04
Dencott+c+Disposable+monopolar+scleral+lensesDencott+Optical+c+Disposable+monopolar+scleral+lensERG+Jet+c+Disposable+monopolar+scleral+lensHenkes+c+Reusable+monopolar+scleral+lensBurian+Allen+c+Reusable+bipolar+scleral+lens
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+LUwwwwwwwwwwwwwwwwwwwwwwww+LU
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+LUwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+Lfwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+Lf
GoldfoilDTLcPlusHK+Loop
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+LWwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+LWwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+LW
Disposable+needle+electrodes wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+Lh
Cupula+electrode+AgBAgClGold+plated+cupula+electrodesBeckmann+type+electrodeAdhesive+rings+for+Beckmann+type+electrodesReflective+dots+for+ocular+motricity+examsDisposable+skin+electrodes+without+cableDisposable+skin+electrodes+with+cableEar+clip+electrode
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+L?wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+L?
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+L?wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+L?
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+GLwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+GL
wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww+GLwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwGL
............................................................. 03
.......................................................... 05
.................................. 07
................................................................... 08
..................................................... 09
............................................................................................. 11
..................................................................... 13
................................................................................ 14
................................................. 15
2015 PRICE LIST2015 PRICE LIST
01. GENERAL INFORMATION
January December 2015 3
EC CERTIFICATION
AllourproductsareECcertified,exceptwhenmentionedexplicitly.Thecertificatesareavailableonrequest. PRICE CONDITIONS
OurpricesarelistedinEuros.ForcountrieswithintheEuropeanUnion,ifthebuyerdoesnothaveanintracommunityVATnumberheshouldaddtheV.A.T.atarateof20percent.
Ordervaluelowerthan 400: Add25 Eurosforpreparationandpacking.The cost of transportation is extra and depends on yourrequirementsfordelivery
Ordervaluehigherthan400: Preparationandpackingarefree.
The cost of transportation is extra and depends on yourrequirementsfordelivery.
Discountsforlargequantities.Pleasecontactus. WHICH ELECTRODE TO CHOOSE?
Electroretinography(ERG)(forsimultaneousrecordingofthetwoeyes)
- 2activeelectrodes(positive)ofthefollowingtypes:sclerallensornonscleral,- 2referenceelectrodes(negative)ofthefollowingtypes:cupulaordisposableskinelectrode,- 1neutralelectrode:cupulaorearclipordisposableskinelectrode.
Visualevokedpotentials(VEP)- 2electrodes(activeandreference):cupulaorneedle(foreachrecordedchannel),- 1neutralelectrode:cupulaorearclipordisposableskinelectrode.
Multifocalelectroretinography(MERG)- duetothesmallamplitudeofrecordedsignals,werecommendtheuseofshieldedcables.
Sensoryelectrooculography(studyofpigmentepithelium)(forsimultaneousrecordingofthetwoeyes)
- 4electrodes(2activeand2reference):Beckmanntype,cupulatypeordisposableskinelectrode,- 1neutralelectrode:cupulaorearclipordisposableskinelectrode.
Dynamicelectrooculography(studyofeyemovements)andelectronystagmography(forsimultaneousrecordingofhorizontalandverticaleyemovementsfromthetwoeyes)
- 8electrodes(4activeand4reference):Beckmanntype,- 1neutralelectrode:cupulaorearclipordisposableskinelectrode.
01. GENERAL INFORMATION
4 January - December 2015
WHICH CONNECTOR TO CHOOSE?
SafetyplugsOnlyplugscompatiblewithactualsafetyregulations(EN60601)
WHICH ELECTRODE PASTE TO USE?
Thepurposeofthesepastesistoimprovetheelectricalcontactbetweentheelectrodeandtheskin.Thequalityofthiscontact ischaracterizedbytheelectric impedanceexpressed inKohms (KiloOhms)and ismeasuredbytheVisionMonitorsystematthetimeofpatientsinstallation.Abadcontactischaracterizedbyexcessivelyhighimpedanceandfrequentlyproducesresultsofbadquality.Theidealimpedancedependsonthetypeofelectrode,butitisrecommendednottoexceed5Kohms.3typesareproposed:AbrasivepastewithpurniceIntendedtoeliminatethedryskinlayer(electricallyinsulating).Itisrecommendedforallelectrodesincontactwiththeskin(electrodescupsoroftype"Beckmann"orelectrodesstuckofsingleuse).Applythispastebyalightmassageofthezoneofpositioningoftheelectrode.Thereafter,cleananddegreasethissamezonewithanalcoholicsolution.
SimpleconductingpasteIntendedtoensurethecontactforBeckmanntypeelectrodes.
AdhesiveconductingpasteIntendedtoensurethecontactfortheelectrodecupsplacedonthescalp.
02. SCLERAL LENSES FOR ERG
January December 2015 5
DENCOTT - DISPOSABLE MONOPOLAR SCLERAL LENSES
COQ25P1 Childsize21x23mm
COQ26M1 Mediumadultsize22x24mm
COQ27G1 Largeadultsize24x26mm
WithblepharostatsPackedperpairSterilepacking3modelsCablesnotincluded.Useexclusively"0.6mmtype"L"(lens)connectorswithreferenceRAC12(seeonp.11). DENCOTT OPTICAL - DISPOSABLE MONOPOLAR SCLERAL LENS
COQ20uni UniversalsizeOpticalqualityDiameter12mm
WithblepharostatsPackedindividuallySterilepackingOnemodel.Flexiblecableof0.7mwithsafetyplugincluded. ERG JET - DISPOSABLE MONOPOLAR SCLERAL LENS
COQ23 ERGJet
SafetyplugDiameter10mm
WithblepharostatsPackedindividuallySterilepackingOnemodel.Flexiblecableof0.7mwithsafetyplugincluded.
02. SCLERAL LENSES FOR ERG
6 January - December 2015
HENKES - REUSABLE MONOPOLAR SCLERAL LENS
COQ80 HenkeselectrodeSmallsizeDiameter17mm
COQ81 HenkeselectrodeLargesizeDiameter20mm
Packedindividually2modelsReusable.Flexiblecablewithsafetyplugincluded. BURIAN ALLEN - REUSABLE BIPOLAR SCLERAL LENS
COQ16
Pediatricsize
COQ17 Adultsize
TheUSstandardNotECmarked(fornonmedicalapplication).Packedindividually2modelsReusable.Cablewithsafetyplugincluded.
03. NON CORNEAL ELECTRODES FOR ERG
January December 2015 7
GOLDFOIL
COQ34 Goldfoil
WithoutcontactwiththecorneaNotsterilePackedindividually1metercablewithsafetyplugincluded. DTL-PLUS
COQ50 DTLplus
WithoutcontactwiththecorneaSterilePackedperpairofelectrodesCablenotincluded.Useexclusively1.0mm"N"(needle)typecableswithreferenceRAC05(seep.11). HK LOOP
COQ70 HKLoop
WithoutcontactwiththecorneaReusablePackedperpairofelectrodesCablenotincluded.Useexclusively"0.6mmtype"L"(lens)cableswithreferenceRAC12(seep.11).
04. NEEDLE ELECTRODES
8 January - December 2015
DISPOSABLE NEEDLE ELECTRODES
AIG05 Needleelectrodes
StainlesssteelSterileDiameter0,35mmLength12mmPackedper10needlesinasterilepackage.Useexclusively1.0mmN(needle)typecableswithreferenceRAC05(seep.11).
05. SKIN CONTACT ELECTRODES
January December 2015 9
CUPULA ELECTRODE Ag/AgCl
ELE12 Ag/AgClcupulaelectrodeDiameter10mm
Ag/AgCldiscNotsterileReusablePackedindividually.1meterlongcablewithsafetyplug. GOLD PLATED CUPULA ELECTRODES
ELE32 GoldplatedcupulaelectrodeDiameter10mm
GoldplateddiskNotsterileReusablePackedper10.1.2meterlongcablewithsafetyplug. BECKMANN TYPE ELECTRODE
ELE22 "Beckmann"typeelectrode
Diameter8mm
"Recessed"diskAg/AgClNotsterileReusablePackedindividually.1mlongcablewithsafetyplug.Veryhighstabilityandlownoise.Suitableforelectrooculographyexams.Electrodefixedtotheskinwithanadhesivering(seeitembelowreferencedCOL01). ADHESIVE RINGS FOR BECKMANN TYPE ELECTRODES
COL01 Adhesivering
Rollof500units.
05. SKIN CONTACT ELECTRODES
10 January - December 2015
REFLECTIVE DOTS FOR OCULAR MOTRICITY EXAMS
DOT12 Reflectivedots
Diameter12mm
DISPOSABLE SKIN ELECTRODES WITHOUT CABLE
ECO10 Smallsize21x34mm
Ag/AgClelectrodesPackedper100Reusablecablenotincluded.UseexclusivelyalligatorclipcableswithreferenceRAC32(seep.11). DISPOSABLE SKIN ELECTRODES WITH CABLE
ECO30 Ag/AgClelectrodeSolidgelforeasyrepositioning
Ag/AgClelectrodesNotsterileSingleusePackof12.1metercablewithsafetyplugincluded. EAR CLIP ELECTRODE
ELE13 Earclipelectrode
Diameter10mm
Associationof2cupulasarticulatedwithaspringNotsterilePackedindividually.1metercablewithsafetyplugincluded.
06. CABLES
January December 2015 11
SIMPLE CABLES
USE."Dencott"sclerallensesHKloopelectrodes
RAC12 "L" cable with 0.6 mmconnectorGreenSafetyplugLength1m
USE.NeedlesDTLelectrodes
RAC05 "N" cable with 1.0 mmconnectorRedorBlackSafetyplugLength1m
USE.Disposableskinelectrodes
RAC32 CablewithalligatorclipSafetyplugLength1m
ImportantnoteCableswith0.6mmconnectorsaregreenandmarkedwithletter"L"(lens).Cableswith1.0mmconnectorsareredorblackandmarkedwithletter"N"(needle).Thesecablesarespecificandmustnotbeusedinreplacementofeachother.
06. CABLES
12 January - December 2015
SHIELDED CABLES
TheseshieldedcablesarerecommendedforallapplicationswithverylowsignalssuchasMultifocalERG
RACBL ShieldedcablesRecommended for allapplications with very lowsignals, such as multifocalERG...
RACCC Shortcircuitbetween+and
inputs
RAC2V1 Cable allowing to share thesameelectrodeon2inputs.
RAC3V1 Cable allowing to share the
sameelectrodeon3inputs.
RAC4V1 Cable allowing to share thesameelectrodeon4inputs.
RAC5V1 Cable allowing to share the
sameelectrodeon5inputs.
07. CONDUCTIVE PASTE
January December 2015 13
PAT01D Conductivepaste142gtube
PAT02B AdhesiveconductivepasteTEN20110gtube
PAT03 ConductivepasteElefixNihonKhoden180gtube
PAT04 Abrasivepaste200gpot
08. SPARE PARTS
14 January - December 2015
LAM04 Redlightsource630nm230V10WForERGroomceiling
LAM05 Portableredilluminator
POI01 Pushbutton2mcable
VER02 Framefor"largefield"refractivelenses
VER03 Nosesupportfortheframeof"largefield"refractivelenses
VER06 EyepatchBlackcolor
09. THE VISION MONITOR IN 2015
January December 2015 15
PSYCHOPHYSICAL EXAMS
Visual field examination allows theevaluation of peripheral vision. Itcan be evaluated with staticperimetry.
This is an additional program for visualfield including specific techniques ofmanual perimetry (Goldmann),blue/yellowperimetry,aswellasmotionperimetry.
Attention visual field is used forscreening patients for visualcognitive disabilities. Its mainapplication is the evaluation of theaptitudefordrivingvehicles.
Measurement of the contrastsensitivitycurve.
Measurementofthedarkadaptationcurve.
Evaluation of visual performance.Includes the measurement of visualacuitywith LandoltorETDRSand themeasurementofsensitivitytoglare.
Evaluation of macular pigmentdensity.Its purpose is an early detection ofpeople at risk of developing agerelatedmaculardegeneration.
Automated test for thedetectionandquantificationofmetamorphopsia.
ELECTROPHYSIOLOGICAL EXAMS
Examination of flash and patternvisual evoked potentials (VEP) andelectroretinograms(ERG).
ExaminationofsensoryEOG
ThemultifocalERGandVEPprogramrealizesspatialmapsofERGandVEPresponses
ThesweepVEPprogramoffersarapidestimationofvisualacuityinbabiesbystudying the VEP response during arapidscanofspatialfrequencies.
OCULOMOTRICITY EXAMS
This program allows themeasurement of pupil size and itsreactivitytovisualstimuli
This program uses the electrographicsignal to analyze eye movements(saccades, pursuits and optokineticnystagmus).
This program performs anautomated analysis of the videoimages of the eye and analyses thescan path during visual exploration,reading,etc.
This program realizes the evaluationof infant's visual acuity by recordingtracking eye movements of astructuredvisualstimulus.
Thisprogramuses the video imagesoftheeyetoanalyseeyemovements(saccades, pursuits and optokineticnystagmus).
METROVISION
Advanced+electrophysiologycombined+with+the+MonPackOne
MonCVOne
Full+visual+field/automated+and+Goldmann
MonBabyBox
Electrophysiology+for+childrenand+ambulatory
Multifunctions+perimeter
MonCV3
MonPackOne
The+2all+in+one2
INQUIRY
ORDER METROVISION+g+rue+des+Platanes+b"Ggh+PERENCHIES+FRANCEFax+:+fyy+y+@h+p,+p"+bp++Online+:+www_metrovision_frUelectrode_US_html++
Phone+:+fyy+y+@h+p,+p"+b,+++export@metrovision_com