Upload
ranjan-kumar
View
176
Download
21
Embed Size (px)
DESCRIPTION
Electrode Qualification E 6010
Citation preview
ELECTRODE QUALIFICATION TEST RECORD FOR
E6010 2.5MM,BATCH NO.:S17 666998
CLIENT : M/S GSPC GAS COMPANY LTD.
CONSULTANT : TRACTEBEL ENGINEERS & CONSTRUCTORS PVT.LTD.
CONTRACTOR : JAIHIND PROJECTS LIMITED TPIA : SGS INDIA PVT. LTD.
PROJECT : HALOL STEEL PIPELINE EXTENSION PROJECT
JPL SGSTECPL /
GSPC GasPREPARED BY &
CHECKED BY REVIEWED BY APPROVED BY
NAME
DESIGNATION
SIGNATURE
DATE
ELECTRODE QUALIFICATION TEST RECORD
DOCUMENT NO. REVPage 1 of 4JPL/GSPC/HALOL
/EQT-010
ALL WELD FOR E6010 2.5mm, Batch NoS17 666998
A: Tested at (Site name) : Store Yard Date of Testing : 08.03.10
Manufacture’s Name : LINCOLN ELECTRIC
Brand Name & Size : FLEET WELD 5P+
Material Specification : SFA-5.1 GRADE-E-6010
Intended for Welded in Positons: 1G (In Plate)
In Combination with(if any) :N.A.
Code of reference (used for testing) : ASME- Sec. II part –C
Special requirements (if any) : Impact at - 30deg C
Size of the Specimen Plate : 300x300x13mm
B: All Weld Tensile Test:-
Pre-heat temperature : 100deg C min
Inter Pass Temperature : 105deg C Min to 175deg C Max
Post Weld Heat Treatment details : N.A
Visual Examination : Satisfactory
Radiography Examination Result:
All Weld Tensile test Results : By M/s. Met-Heat Engineers Pvt. Ltd Vadodara
Report No: 84 ZJ/2010 Date: 27.03.2010
Gauge Diameter
Area (mm2)
0.2% Proof Load(PSI)
0.2% Proof Stress (PSI)
Ultimate Load(PSI)
U.T.S Gauge Length(mm)
Final Length(mm)
% of Elongation
ELECTRODE QUALIFICATION TEST RECORD
DOCUMENT NO. REVPage 2 of 4JPL/GSPC/HALOL
/EQT-010
6.43 32.47 15325 68457 19000 84871 25.4 31.00 22.05
C.IMPACT TEST:
IMPACT TEST RESULT AT -30deg C: By M/s. Met-Heat Engineers Pvt. Ltd Vadodara
Report No: 9-MC/2010 Date: 27.03.2010
LocationSpecimen Size(mm)
Energy absorbed in joules
Average Value in Joule
I II III IV V
Weld 10x10 52J 54J 68J 40J 70J 58J
Required Value: 35J, Individual 28J
D: CHEMICAL ANALYSIS:
Chemical Analysis Results: By M/s. Met-Heat Engineers Pvt. Ltd VadodaraReport No: 290MC/2010 Date: 27.03.2010
Result (Obtained Value): Satisfactory
% CARBON 0.154
%MANGANESE 0.529
%SILICON 0.239
ELECTRODE QUALIFICATION TEST RECORD
DOCUMENT NO. REVPage 3 of 4JPL/GSPC/HALOL
/EQT-010
%PHOSPHOROUS 0.009
%SULPHUR 0.006
%NICKEL 0.029
%CHROMIUM 0.028
%MOLYBDENUM 0.017
%VANADIUM 0.004
Welder Name : Mr. Bhalwant Thakor
Test conducted by: STORE YARD
Destructive test conducted by: By M/s. Met-Heat Engineers Pvt. Ltd Vadodara
These statements in this record are correct. The test joints were prepared, welded and tested in accordance with the requirement of ASME Sec II C &TE-India Specification.
For JPLFor SGS(TPIA) For TE-India/GSPC Gas
Name: Name: Name:
Sign: Sign: Sign:
Date: Date: Date:
ELECTRODE QUALIFICATION TEST RECORD
DOCUMENT NO. REVPage 4 of 4JPL/GSPC/HALOL
/EQT-010