5
ELECTRODE QUALIFICATION TEST RECORD FOR E6010 2.5MM, BATCH NO.:S17 666998 CLIENT : M/S GSPC GAS COMPANY LTD. CONSULTANT : TRACTEBEL ENGINEERS & CONSTRUCTORS PVT.LTD. CONTRACTOR : JAIHIND PROJECTS LIMITED TPIA : SGS INDIA PVT. LTD. PROJECT : HALOL STEEL PIPELINE EXTENSION PROJECT JPL SGS TECPL / GSPC Gas PREPARED BY & CHECKED BY REVIEWED BY APPROVED BY NAME DESIGNATION SIGNATURE DATE ELECTRODE QUALIFICATION TEST RECORD DOCUMENT NO. REV Page 1 of 5 JPL/GSPC/HALOL /EQT-01 0

Electrode Qualification E 6010

Embed Size (px)

DESCRIPTION

Electrode Qualification E 6010

Citation preview

Page 1: Electrode Qualification E 6010

ELECTRODE QUALIFICATION TEST RECORD FOR

E6010 2.5MM,BATCH NO.:S17 666998

CLIENT : M/S GSPC GAS COMPANY LTD.

CONSULTANT : TRACTEBEL ENGINEERS & CONSTRUCTORS PVT.LTD.

CONTRACTOR : JAIHIND PROJECTS LIMITED TPIA : SGS INDIA PVT. LTD.

PROJECT : HALOL STEEL PIPELINE EXTENSION PROJECT

JPL SGSTECPL /

GSPC GasPREPARED BY &

CHECKED BY REVIEWED BY APPROVED BY

NAME

DESIGNATION

SIGNATURE

DATE

ELECTRODE QUALIFICATION TEST RECORD

DOCUMENT NO. REVPage 1 of 4JPL/GSPC/HALOL

/EQT-010

Page 2: Electrode Qualification E 6010

ALL WELD FOR E6010 2.5mm, Batch NoS17 666998

A: Tested at (Site name) : Store Yard Date of Testing : 08.03.10

Manufacture’s Name : LINCOLN ELECTRIC

Brand Name & Size : FLEET WELD 5P+

Material Specification : SFA-5.1 GRADE-E-6010

Intended for Welded in Positons: 1G (In Plate)

In Combination with(if any) :N.A.

Code of reference (used for testing) : ASME- Sec. II part –C

Special requirements (if any) : Impact at - 30deg C

Size of the Specimen Plate : 300x300x13mm

B: All Weld Tensile Test:-

Pre-heat temperature : 100deg C min

Inter Pass Temperature : 105deg C Min to 175deg C Max

Post Weld Heat Treatment details : N.A

Visual Examination : Satisfactory

Radiography Examination Result:

All Weld Tensile test Results : By M/s. Met-Heat Engineers Pvt. Ltd Vadodara

Report No: 84 ZJ/2010 Date: 27.03.2010

Gauge Diameter

Area (mm2)

0.2% Proof Load(PSI)

0.2% Proof Stress (PSI)

Ultimate Load(PSI)

U.T.S Gauge Length(mm)

Final Length(mm)

% of Elongation

ELECTRODE QUALIFICATION TEST RECORD

DOCUMENT NO. REVPage 2 of 4JPL/GSPC/HALOL

/EQT-010

Page 3: Electrode Qualification E 6010

6.43 32.47 15325 68457 19000 84871 25.4 31.00 22.05

C.IMPACT TEST:

IMPACT TEST RESULT AT -30deg C: By M/s. Met-Heat Engineers Pvt. Ltd Vadodara

Report No: 9-MC/2010 Date: 27.03.2010

LocationSpecimen Size(mm)

Energy absorbed in joules

Average Value in Joule

I II III IV V

Weld 10x10 52J 54J 68J 40J 70J 58J

Required Value: 35J, Individual 28J

D: CHEMICAL ANALYSIS:

Chemical Analysis Results: By M/s. Met-Heat Engineers Pvt. Ltd VadodaraReport No: 290MC/2010 Date: 27.03.2010

Result (Obtained Value): Satisfactory

% CARBON 0.154

%MANGANESE 0.529

%SILICON 0.239

ELECTRODE QUALIFICATION TEST RECORD

DOCUMENT NO. REVPage 3 of 4JPL/GSPC/HALOL

/EQT-010

Page 4: Electrode Qualification E 6010

%PHOSPHOROUS 0.009

%SULPHUR 0.006

%NICKEL 0.029

%CHROMIUM 0.028

%MOLYBDENUM 0.017

%VANADIUM 0.004

Welder Name : Mr. Bhalwant Thakor

Test conducted by: STORE YARD

Destructive test conducted by: By M/s. Met-Heat Engineers Pvt. Ltd Vadodara

These statements in this record are correct. The test joints were prepared, welded and tested in accordance with the requirement of ASME Sec II C &TE-India Specification.

For JPLFor SGS(TPIA) For TE-India/GSPC Gas

Name: Name: Name:

Sign: Sign: Sign:

Date: Date: Date:

ELECTRODE QUALIFICATION TEST RECORD

DOCUMENT NO. REVPage 4 of 4JPL/GSPC/HALOL

/EQT-010