EC-Lab, BT-Lab, MT-Lab, SCAN-Lab products
Generalelectrochemistry
Corrosion Batterytesting Supercapacitors Sensors Coatings Fuel/solarcells Materials Localimaging
Electrochemistryinstruments
Bio-LogicScienceInstruments
SAS (founded in 1983) is located near Grenoble in the French Alps. We design and manufacture high performance, research laboratory instruments and software for electrochemistry, battery testing, fuel cell and material testing.
Bio-Logic’s product range is based on a modular and flexible design. We offer electrochemical workstations (EC-Lab division) and battery test equipments (BT-Lab division) from single channel up to 128-channel systems, integrating EIS capability and high current boosters.
MT-Lab division offers a complete solution for material characterization. It provides a complete system including impedance analyzer, furnace, sample holders and software for the control of the instruments and for data acquisition.
In 2012, Bio-Logic SAS extended its choice of instruments to the scanning electrochemical workstations. The Scan-Lab division is dedicated to high resolution electrochemical mapping tools. These products are developed, designed and manufactured by Uniscan Instruments Ltd., a company based in Macclesfield, UK. For more than 20 years, Uniscan Instruments Ltd. have been at the cutting edge of scanning probe electrochemistry technology.
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Hig
h c
urr
ent
inst
rum
ents
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
Boo
ster
s S
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
ELECTROCHEMISTRY INSTRUMENTS4/5
Bio-LogicScienceInstrumentsAuniqueandcompleteproductrange
-Morethan20differentpotentiostats/galvanostats-Singletomultichannelsystems-StandaloneFRAanalyzer&Built-inEISanalyzer(ElectrochemicalImpedanceSpectroscopy)-Lowcurrentoptions-Highcurrentpotentiostats-Built-inorexternalhighcurrentboosters-Electronicloadbox-Fuelcellteststations-Configurationcanbeadaptedtotheapplication
Modularsystems-Modularchassishavingfrom1to16boardslots-Upto16independentpotentiostats-Highcurrentboosters:2,4,5,8,10,20,80and100A-Extendedvoltagerangeto±15V,±30V,±48V,-Loadbox(50V,150A)-Lowcurrentoptions(downtoaA)-Multipleusersystems(upto16)-LSG(LinearScanGenerator)toperformanalogvoltageramp-Boostersinparallelupto150A(VMP-300technology)-Modularscanningworkstationswithupto9differentlocaltechniques(dc-SECM,ac-SECM,LEIS,SKP,SVET…)-Batterycycler-Fullyfeaturedimpedanceanalyzer
Controlledbyapowerfulsuite of software-Comprehensivesoftwarepackage-Dedicatedtechniquesformoststandardelectrochemicalapplications-Multi-techniqueexperimentbuilder-Externaldevicescontrol-Multiplegraphdisplay-Dataanalysis&fit-Safety&experimental
limits-Softwarecalibration
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Hig
h c
urr
ent
inst
rum
ents
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
Boo
ster
s S
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Hig
h c
urr
ent
inst
rum
ents
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
Boo
ster
s S
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
s
ELECTROCHEMISTRY INSTRUMENTS6/7
Singlepotentiostats/galvanostats
PG-581 8SP-50 8SP-150 9SP-200 9SP-240 10SP-300 10
Multipotentiostats/galvanostats
VSP 12VMP312VSP-300 13VMP-300 13BiStat3200 14SensorStat 14
Boosters VMP-300technology 16VMP3technology 18
Highcurrentinstruments
HCP-803 20HCP-1005 20CLB-2000 20
Batterytest stations
MPG-2xxseries 22BCS-8xxseries 24
Softwarepackage
EC-Lab®/BT-Lab® 26EC-Lab®graphics 27ElectrochemicalImpedanceSpectroscopy 28UiEChem™/UiECorr™ 29
Fuelcelltest stations
FCTseries30FC-Lab 31
Impedanceanalyzer
Conductivitymeter
MTZ-3532
MCS1033
Scanningsystems
Techniquesandfocus 34M370/M470 35
BatteriesCorrosion
Sensors
Education/training
General electrochemistry
Solar cells, photovoltaic systems
Power
Fuel cells
PL
UG
- IN
HY
BR I D E L E C T R I C V
EH
I CL
E
mpg
Coatings
Nanotechnology
Supercapacitors
Modular electrochemical workstations designed to address applications in...
Sca
nn
ing
sy
stem
s
Singlepotentiostats/galvanostats
ELECTROCHEMISTRY INSTRUMENTS8/9
SP-50 Affordableandeasy-to-useTheSP-50isaneconomical,valueorientedpotentiostat/galvanostatdesignedtoaddressapplicationsingeneralelectrochemistryandcorrosion.Containedinasimple,compactchassis,theSP-50isafixedconfigurationunitwithnooptions.Itistargetedfornewresearchersinthefieldofelectrochemistryandanidealinstrumentforteachingandeducation.Itoffersgoodperformancewithasmallpricetag.
PG-581 On-sitemeasurementWhenyouneedtomakethoseon-sitetrialsorroutinefieldmeasurements,thePG-581goeswithyou.Thecompactdesignprovidesauserconfigurableinstrumentfordemandingresearchapplicationsandin-fielduseviaitsinternalrechargeablebattery.
SP-200 High-end potentiostat/galvanostat SP-200isthenewest,researchgrade,value-orientedpotentiostat/galvanostatintheEC-Lab®productrange.Withexcellentspecificationsinaportablechassis,theSP-200istheperfectinstrumentforanyapplicationinelectrochemistryespeciallycorrosion.TheSP-200offersoutstandingfeaturessuchasafloatingmode,analogfiltering,abuilt-incalibrationboard,and9stabilitybandwidthsforabettercontrolofthecell.Additionally,theSP-200canbepurchasedwithastandardDCpotentiostatoranEIScapableone.ThereisalsoanUltraLowCurrent(ULC)option.On-siteexperimentscanbeperformedthankstoitsportabledesign.
SP-150 Research gradeworkstationTheSP-150isafullfeaturedeconomicalresearchgradepotentiostat/galvanostat.Withitsmodularchassis,thisinstrumentcanbecustomizedtoaddressallapplicationsintheareaofclassicalelectrochemistry.TheSP-150potentiostatconfigurationcanbeselectedatpurchasetoincludeanEIS-capablepotentiostat,andalowcurrentoption(1nAfullscalerange).Itcanalsobeconnectedtoexternalhighcurrentboosters(2,5,10,20,80and100A)or2kWloadbox.
dI/d
t/m
A/s
0.04
0.02
0
-0.02
-0.04
Ewe/V vs. SCE0.60.40.20-0.2
0.2
0.1
0
-0.1
-0.2
<I>/
mA
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Education/training Generalelectrochemistry Corrosion Sensors Electroanalytical
Applications
Options-Floating-±8Vscanvoltage-5-workingelectrodemultiplexer-Computer-programmableexperiment
Education/training Generalelectrochemistry
Applications
Generalelectrochemistry Sensors Corrosion Energysources Coatings
Applications
Options-Lowcurrent:fullscalerangedownto1nA-Built-inEISanalyzer:
upto1MHz-Externalcurrentboosters:
2,5,10,20,80and100A-Loadbox:2kW-RDEcontrolkit
Generalelectrochemistry Sensors Corrosion Coatings Materials
Applications
Options-UltraLowCurrent:
fullscalerangedownto1pA-Built-inEISanalyzer:
upto7MHz-LinearScanGenerator:
1MV/s,acquisition1µs-SP-200suitcase
Hig
h c
urr
ent
inst
rum
ents
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
Boo
ster
s S
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
Single potentiostats/galvanostats
ELECTROCHEMISTRY INSTRUMENTS10/11
SP-300 Fast,sensitive,stableandmodularSP-300isastate-of-the-artresearchgradepotentiostat/galvanostat/EISwithremarkablespecifications.ThebasespecificationsarethesameforboththeSP-300andtheSP-200includingfloatingmode,analogfiltering,built-incalibrationboard,andstabilitybandwidths.TheSP-300’smodularchassisacceptanoptionalhighcurrent/highvoltageoptionboard.Alternatively,theSP-300canacceptasecondpotentiostatboard(eitherstandardorEIS)andperformasaBipotentiostat.Itisalsoamultipleusersystemaseachchannelboardcanbeusedindependentlybytwodifferentresearchers.
SP-240 PowerfulinacompactchassisSP-240isa4Apotentiostat/galvanostat/EISwithexcellentspecificationsinaportablechassis,theSP-240istheperfectinstrumentforanyapplicationinelectrochemistryespeciallyenergydevicestesting.AsapartoftheSP-200/300productrange,theSP-240benefitsinthesamespecificationsandoptions.
ModulesPG-581 SP-50/SP-150 SP-200/ SP-240/SP-300
Std ElS LC* Booster(1) Std ElS ULC** Booster(1) LSG***EducationGeneral electrochemistryAnalytical electrochemistryCorrosionNanotechnology/sensorsBatterySupercapacitorFuel cellsSolar cellsElectrolysisCoatingsMaterialsFor each instrument, modules can be mixed together
suitable recommanded excellent* LC: Low Current ** ULC: Ultra Low Current *** LSG: Linear Scan Generator(1): Booster, more details on page 16
PG-581 SP-50/SP-150 SP-200/SP-240/SP-300
FeaturesMax. number of channels 1 1 1 (SP-300: 2)EIS capability n.a. 10 μHz to 1 MHz (SP-50: n.a.) 10 μHz to 7 MHzLinear Scan Generator n.a. n.a. yes (1 MV/s), sampling rate 1 μsFloating option yes n.a. yesFilters n.a. numeric analog/numericAcquisition time 10 μs 20 μs 12 μs (1 μs with LSG option)Electrodes connections 2, 3 2, 3, 4, 5 2, 3, 4, 5IR compensation n.a. manual, EIS, current interrupt
(software)manual, EIS, current interrupt (software and hardware)
CurrentMaximum ±20 mA ±800 mA SP-200: ±500 mA,
SP-240: ±4 A, SP-300: ±10 A with 10 A booster
Current ranges
with standard board 8: 1 nA to 10 mA 6: 10 μA to 1 A 9: 10 nA to 1 Awith low current option - 9: 1nA to 100 mA (SP-50: n.a.) 13: 1 pA to 1 A
Lowest accuracy
with standard board ±10 pA on 1 nA range ±20 nA on 10 μA range ±100 pA on 10 nA rangewith low current option - ±2 pA on 1 nA range ±100 fA on 1 pA range
Lowest resolution
with standard board 61 fA 0.8 nA on 10 μA range 0.8 pA on 10 nA rangewith low current option - 80 fA on 1 nA range 80 aA on 1 pA range
Current booster
internal n.a. n.a. SP-200: n.a., SP-240: 4 A, SP-300: 1 A, 2 A, 4 A, 10 A
external n.a. 2, 5, 10, 20, 80, 100 A, 2 kW load box, (SP-50: n.a.)
n.a.
Input impedance 0.1 TΩ (//5 pF) 1 TΩ (//20 pF) Standard: 1 TΩ (//10 pF), ULC: 100 TΩ (//6 pF)
VoltageCompliance ±8 V ±10 V ±12 V (±48 V with 48 V booster)Max applied potential ±2 V (±8 V in option) 0-20 V ajustable
SP-50: n.a.SP-200: ±10 V, SP-240: -3;10 V, SP-300: ±48 V with 48 V booster
Resolution 61 μV on ±2 V 5 μV on 200 mV 1 μV on 60 mVAccuracy < 5 mV on ±2 V < 5 mV on ±2.5 V < ±1 mVRange ±2 V (±8 V in option) ±2.5 V, ±5 V, ±10 V ±25 mV, ±250 mV, ±2.5 V, ±5 V, ±10 VMaximum scan rate 10 V/s 200 V/s 200 V/s (1 MV/s with LSG option)
Control amplifierPotentiostat bandwidth 1.6 MHz 1 MHz 8 MHzPotentiostat rise/fall time 1 V/μs into 1 kΩ < 2 μs < 500 ns
GeneralI/O (analog/TTL) n.a./n.a. 3/2 3/2Interfaces USB 2.0 Ethernet, USB 2.0 Ethernet, USB 2.0Dimensions (W x D x H) 84 x 180 x 52.5 mm 136 x 377 x 197 mm SP-200: 167 x 410 x 225 mm,
SP-240/SP-300: 205 x 410 x 225 mmPower requirements 15 W 110 W 350 WWeight (chassis + board) 0.3 kg SP-50: 4.0 kg, SP-150: 4.5 kg SP-200: 6 kg, SP-240/SP-300: 7.5 kgn.a.: not available
0.05 0.1 0.15 0.20
0.02
0.04
0.06
0.08
0.1
Re (Z)/Ohm
-Im(Z
)/Ohm
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Applications
Specification overview
Singlepotentiostats/galvanostats
Batteries Corrosion Coatings Electrolysis Generalelectrochemistry
Applications
Options-UltraLowCurrent:
fullscalerangedownto1pA-Built-inEISanalyzer:
upto7MHz-LinearScanGenerator:
1MV/s,acquisition1µs-SP-240suitcase
Education/training Generalelectrochemistry
(RRDEmeasurement) Sensors Corrosion Electrolysis/anodizing Coatings
Applications
Options-UltraLowCurrent:
fullscalerangedownto1pA-Built-inEISanalyzer:
upto7MHz-Internalamplifiers:
±1A/±48V,±2A/±30V,±4A/[-3;14]V,±10A/[0;5]V
-Bi-potentiostat-LinearScanGenerator:
1MV/s,acquisition1µs-SP-300suitcase
Hig
h c
urr
ent
inst
rum
ents
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
Boo
ster
s S
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
ELECTROCHEMISTRY INSTRUMENTS12/13
VSP Affordable research grademultichannelsTheVSPisaresearchgradepotentiostatsystemina5-channelmodularchassis.ThisallowstheVSPtoaddadditionalcapabilityinthewayofplug-in“modules”.ThesemodulesprovideEIScapability(includedonthepotentiostatboard),lowcurrentmeasurement(uses1additionalslot),4Acurrentbooster(twoslots)andadditionalpotentiostatchannels(eachonetakesoneslot).Theinternal4AoptiontakestwoslotsintheVSPchassisandrequiresapotentiostatboardtobeusedwithit.Externalboostersfrom2Aupto100AcanbeusedwitheachchannelintheVSP.
VSP-300Versatile high-end multipotentiostatTheVSP-300multichannelpotentiostat/galvanostat/EISisaversatileinstrumentoffering6slotstosetfrom1to6channelboards.EachchannelboardcanaccomodateanUltraLowCurrentcableandcanbeassociatedwithoneorseveralboosterkits.Upto4boosterkitscanbepluggedinparalleinoneVSP-300chassis.
VMP3 16-channelresearch gradepotentiostatsystemTheVMP3isaresearch-grademulti-channelpotentiostat.Withitsmodularchassisdesign,upto16independentpotentiostatchannelscanbeinstalled.TheVMP3canbeequippedwithadditionalcapabilities,includinglowcurrentmeasurement,impedance.EachpotentiostatinstalledintheVMP3canbeconnectedtoanexternalhighcurrentboosterchannel.TheVMP3isalsoamultipleusersystem.ThankstotheEthernetLANconnectioncapability,severalcomputerscanbeconnectedtotheunitatthesametime.
VMP-300 UltimatemultichannelelectrochemicalworkstationTheVMP-300isthemostmodularchassisofourproductrangeoffering16slotsforpotentiostats/galvanostats/EISboardsand/orboosterboards.Thechannelsandboosterboardscanbecombinedinthechassiseithertohavemanychannelsortoreachhighcurrents.EISmeasurementscanbeaddedasanoption.Thebuilt-inEIShasawidefrequencyrangeupto7MHz.LowcurrentsensitivitycanbeimprovedusingtheUltraLowCurrentoption.
Ewe/V-0.5-1-1.5
log
(|<I>
/mA|
)
0
-2
-4
-6
-8
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
s
Multipotentiostats/galvanostats
Electroanalytical Generalelectrochemistry
Corrosion Sensors
Energysources Energystorage
Batteries Coatings
Applications
Options-Lowcurrent:
fullscalerangedownto1nA-Built-inEISanalyzer:
upto1MHz-Externalcurrentboosters:
2,5,10,20,80and100A-ExternalloadboxLB-2000(50V/-150A)-Internal±4AboosterkitforVSPonly-SAM50forstack(50V)measurement
(upto30elementswith3SAM-50)forVMP3only-Additionalpotentiostat/galvanostat/EIS
Batteries/supercapacitors Fuel/photovoltaiccells Generalelectrochemistry Corrosion Sensors Materials Energystorage
Applications
Options-UltraLowCurrent:fullscalerangedownto1pA(resolutionof80aA)-EISmeasurement:
upto7MHz-LinearScanGenerator:
1MV/s,acquisition1µs-Currentboosters:
±1A/±48V,±2A/±30V,±4A/[-3;14]V,±10A/[0;5]V-Additionalpotentiostat/galvanostat/EIS
Hig
h c
urr
ent
inst
rum
ents
Bat
tery
te
sts
tatio
nsB
oost
ers
Sof
twar
e
pack
age
Fuel
cel
l te
st s
tatio
nsM
ater
ials
& li
quid
s te
st s
yste
ms
Sca
nn
ing
sy
stem
s
Multi potentiostats/galvanostats
ELECTROCHEMISTRY INSTRUMENTS14/15
BiStat 3200High quality bipotentiostatfordemandingresearchapplicationsWithitstrue2-channelmeasurementcapability,theBiStat 3200providesthefeaturesfoundinatraditionallaboratorybasedinstrument,inadualdesign.TheBiStat 3200canoperateastwoindependentisolatedinstrumentsorasabipotentiostat/bigalvanostat.Thelowestfullscalerangeis1nA(resolutionof61pA).
SensorStatDedicatedtosensorapplicationsThemodulardesignprovidesauserconfigurablesystemfordemandingresearchapplications.TheSensorStatinconfigurablefor8to14channels.Byconnectinga14-channelSensorStattootherSensorStatunits,anextendedsystemiscreated.A98-electrodesensorwaycanbeindividuallyaddressedbychainingtogetherseven14-channelsystems.
BiStat 3200/SensorStat VSP/VMP3 VSP-300/VMP-300Modules Std ElS LC* Booster(1) Std ElS LC* Booster(1)
EducationalGeneral electrochemistryElectroanalyticalCorrosionNanotechnology/sensorsRRDE/catalysisBattery/supercapacitorFuel cells/stacksSolar cellsElectrolysisCoatingsFor each instrument, modules can be mixed together
suitable recommanded excellent* LC: Low Current (1): Booster, more details on page 16
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
s
Applications
BiStat 3200/SensorStat VSP/VMP3 VSP-300/VMP-300
FeaturesMaximum number of channels BiStat 3200: 2,
SensorStat: 14VSP: 5, VMP3: 16
VSP-300: 6, VMP-300: 16
EIS capability n.a. 10 μHz to 1 MHz 10 μHz to 7 MHzLinear Scan Generator n.a. n.a. yes (1 MV/s), sampling rate 1 μsFloating option yes CE to Ground yesFilters n.a. numeric analog/numericAcquisition time 10 μs 20 μs 12 μs (1 μs with LSG option)Electrodes connections 2, 3 2, 3, 4, 5 2, 3, 4, 5IR compensation n.a. manual, EIS, current interrupt
(software)manual, EIS, current interrupt (software and hardware)
CurrentMaximum current ±20 mA ±400 mA ±500 mA (VMP-300: 150 A with
fifteen 10 A boosters)Current ranges
with standard board 8: 1 nA to 10 mA 6: 10 μA to 1 A 9: 10 nA to 1 Awith low current option - 9: 1nA to 100 mA (SP-50: n.a.) 13: 1 pA to 1 A
Lowest accuracy
with standard board ±10 pA on 1 nA range ±20 nA on 10 μA range ±100 pA on 10 nA rangewith low current option - ±2 pA on 1 nA range ±100 fA on 1 pA range
Lowest resolution
with standard board 61 fA 0.8 nA on 10 μA range 0.8 pA on 10 nA rangewith low current option - 80 fA on 1 nA range 80 aA on 1 pA range
Current booster
internal n.a. 4 A for VSP only 1 A, 2 A, 4 A, 10 Aexternal n.a. 2, 5, 10, 20, 80, 100 A,
2 kW load boxn.a.
Input impedance 0.1 TΩ (//5 pF) 1 TΩ (//20 pF) 1 TΩ (//10 pF), ULC: 100 TΩ (//6 pF)
VoltageCompliance ±8 V ±10 V ±12 V (±48 V with 48 V booster)Max applied potential ±2 V (±8 V in option) 0-20 V ajustable ±10 V (±48 V with 1 A/48 V booster)Resolution 61 μV on ±2 V 5 μV on 200 mV 1 μV on 60 mVAccuracy < 5 mV on ±2 V < 5 mV on ±2.5 V < ±1 mVRange ±2 V ±2.5 V, ±5 V, ±10 V ±2.5 V, ±5 V, ±10 V, ±25 mV, ±250 mVMaximum scan rate 10 V/s 200 V/s 200 V/s (1 MV/s with LSG option)
Control amplifierPotentiostat bandwidth 1.6 MHz 1 MHz 8 MHzPotentiostat rise/fall time 1 V/μs into 1 kΩ < 2 μs < 500 ns
GeneralI/O (analog/TTL) n.a./n.a. 3/2 3/2Interfaces USB 2.0 Ethernet, USB 2.0 Ethernet, USB 2.0Dimensions (W x D x H) BiStat 3200: 213 x 110 x 240 mm,
SensorStat: 450 x 320 x 135 mmVSP: 435 x 335 x 95 mm,VMP3: 495 x 465 x 260 mm
VSP-300: 254 x 517 x 337 mm,VMP-300: 534 x 565 x 315 mm
Power requirements BiStat 3200: 15 W, SensorStat: 130 W
VSP: 300 W,VMP3: 650 W
VSP-300: 650 W,VMP-300: 1500 W
Weight (chassis + pstats) BiStat 3200: 2.1 kg, SensorStat: 14 kg
VSP: 8 kg,VMP3: 20 kg
VSP-300: 20 kg,VMP-300: 30 kg
n.a.: not available
Specification overview
Multipotentiostats/galvanostats
Ewe/V0.50-0.5
I/nA
0
-20
-40
-60
-80
-100
-120
Electroanalyststudies Dualelectrodevoltammetry Ring-diskelectrodestudies Electrochemicalsensors Biomedical Electroanalytical Corrosion
Applications
Options-RC10Vrotatorcontroller-±8Vscanrange-Floating-±8Vcompliance
Hig
h c
urr
ent
inst
rum
ents
Bat
tery
te
sts
tatio
nsB
oost
ers
Sof
twar
e
pack
age
Fuel
cel
l te
st s
tatio
nsM
ater
ials
& li
quid
s te
st s
yste
ms
Sca
nn
ing
sy
stem
s
Boosters high current and high voltage
VMP-300Boosters
ELECTROCHEMISTRY INSTRUMENTS16/17
±1 A/±48 V ±2 A/±30 V ±4 A/[-3;14] V ±10 A/[1;6] V ±30 A/[0;48] V
CurrentCompliance ±1 A ±2 A ±4 A ±10 A ±30 A (±120 with 4 units)Accuracy < 2 mA on 1 A range < 4 mA on 2 A range < 8 mA on 4 A range < 60 mA on 10 A range < 240 mA on 30 A range
VoltageCompliance ±49 V ±30 V -3 V ; +14 V -1 ; +6 V 0 ; +48 VControl ±48 V ±30 V -3 V ; +10 V -1 ; +6 V 0 ; +48 V
FeaturesEIS frequencies 2 MHz - 10 μHz 1 MHz - 10 μHz 1 MHz - 10 μHz 1 MHz - 10 μHz 500 kHz - 10 μHz Bandwidth (-3 dB) > 2 MHz > 3 MHz > 4 MHz > 8 MHz 800 kHzSlew rate (no load) > 15 V/μs 50 V/μs 50 V/μs 50 V/μs > 20 V/μsRise/fall time (no load) < 250 ns < 200 ns < 200 ns < 200 ns < 3 μsFloating mode yes yes yes yes yesParallel ability no yes yes yes yes up to 4Connection 2, 3, 4, 5 leads 2, 3, 4, 5 leads 2, 3, 4, 5 leads 2, 3, 4, 5 leads 2, 3, 4 leads
HCV-3048Current & voltage booster.The unmatched combination of power and speedEnergystorageandconversionresearchpresentsnewandchallengingtechnicaldemandseachandeveryday.DevelopmentsinBatteries, Electrolyzer or Fuel Cellsrequireleadingedgeandlaboratoryprovendiagnostictoolsformeaningfulrealworldtestresults.
TheHCV-3048isdesignedforbatterystack/packcharacterizations.Thecontinuousmaximumcurrentof±30Aforasingleunitcanbeextendedupto±120Abyconnectingfourunitsinparallel.Thecontrolvoltagerangeis0-48V.
Impedance spectroscopy (EIS) providesvaluableinformationonenergystorageandconversionproducts,helpingtoidentifythekineticpropertiesofmultipleprocesseswithinthedeviceundertest.TheHCV-3048bringsunmatchedinsighttohigh power systemsthathasbeenunattainableuntilnow.
Internal boostersHigh current and high voltage boosters. From1 pA to 150 Aandfrom5 V to 48 VArangeofinternalboostershasbeendesignedtoincreasethecurrentandthevoltagespecificationsoftheSP-300,VSP-300,andVMP-300.Fourmodelsareavailable:±1A/±48V,±2A/±30V,±4A/[-3;14]V,±10A/[0;5]V.Dependingontheinstrumentchassis,severalsimilarboosterscanbeconnectedinparalleltoexpandthemaximumcurrentofthesystem.Thisfeatureisavailableforthe2A,4Aand10Aboosters.
Configurations±1A/±48V±2A/±30V±4A/[-3;14]V±10A/[0;5]V
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
oost
ers
-Boosterrangeincludedintheautoranging
-EIScapabilityupto2MHz-Plug-inmodules-Plug-and-play-5-leadconnectiontype-Parallelboosterstoincrease
themaxcurrent
Features
-Maxcurrent±30A-Voltagerange0-48V-EISupto500kHz-Stackable±120A
Features
Specifications
Hig
h c
urr
ent
inst
rum
ents
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
VMP3Boosters
Internal & external BoostersDeliver more powertoyourapplicationwithahighcurrentboosterSP-150,VSPandVMP3potentiostatscanbeinterfacedtoaseparatecurrentboosterunit.Thesemodularboosterunitscanhavedifferentboostermodulesplacedinsidethem(2,5,10,or20A).Inthestandardboosterchassisthereare8availableboosterslotsandthecurrentlimitis20A.Eachboosterchannelisconnectedtoapotentiostatboard.Thereisan80or100Aboosterunit.The80Aand100Aboosterexistalsoasastandalonesystem(HCP-803,HCP-1005seepages15/16).One4AboosterkitcanbedirectlyinsertedintheVSPchassis.
Configurations-External:±2A,±5A,±10A,±20Aon±10Vadjustablefrom–20to+20V
±80Aon±3V±100Aon(0.6-5)V
-Internalkit: ±4Aon20VonlyforVSP
FlexP0160Power EIS with FlexP0160 EISprovidesvaluableinformationaboutworkingelectricaldevices.Ithelpsidentifythekineticpropertiesofmultipleprocesseswithinthedeviceundertest.FlexP0160andPowerEISbringsunmatchedinsighttoveryhigh-powerunitsthathavebeenoutofreachuntilnow.TheFlexP0160PowerUnitcoversafullrangeofDCandACtestsignalsfordevicesinthe100’sofampsandupto100voltsrange.DrivenbyaVMP3potentiostat/galvanostat,theFlexP0160bringsthebestofelectrochemistryknowledgeandmethodsintothehighpowerfield.
-Voltagesto60V-Currentto50A(upto200A)-Upto4Parallelunitto12kW-10kHz-1mHzEIScapable-3kWcontinuouswithwatercooling-1.5kWcontinuouswithaircooling-Celltemperaturemeasurementincluded
Features
-Boosterrangeincludedintheautoranging(forboostersupto20A)
-EIScapability-Plug-inmoduleorexternalchassis-Plug-and-play-5-leadconnectiontype
Features
Boosters high current and high voltage
ELECTROCHEMISTRY INSTRUMENTS18/19
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
oost
ers
2/4/5 A 10/20 A 80/100 A FlexP0160
CurrentMaximum current 2 A: ±2 A,
4 A: ±4 A,5 A: ±5 A
10 A: ±10 A,20 A: ±20 A
80 A: ±80 A,100 A: ±100 A
50 A up to 200 A (4 in parallel)
Current accuracy 2 A: < 4 mA on 2 A range, 4 A: < 8 mA on 4 A range,5 A: < 10 mA on 5 A range
10 A: < 20 mA on 10 A range,20 A: < 40 mA on 20 A range
80 A: < 160 mA on 80 A range, 100 A: < 200 mA on 100 A range
0.2% of value ±0.1% FSR
VoltageCompliance adjustable ±10 V range adjustable ±10 V range 80 A: ±3 V
100 A: 0.6 - 5 V±50 A: 2 - 58 V (water cooled)
Control voltage ±20 V ±20 V ±3/5 V [1; 60] V
FeaturesMax frequency (accuracy 1%, 1°) 2 A: up to 150 kHz,
4 A: up to 130 kHz,5 A: up to 120 kHz
10 A: up to 80 kHz,20 A: up to 80 kHz
80 A: up to 15 kHz,100 A: up to 10 kHz
10 kHz
Bandwidth 1 MHz 1 MHz 1 MHz - Rise time and fall time 15 μs 25 to 60 μs 95 μs to 1.7 ms < 10 μsParallel ability no no no yes up to 4Connection 2, 3, 4, 5 terminal leads 2, 3, 4, 5 terminal leads 2, 3, 4, 5 terminal leads 2, 3, 4 terminal leads
General1 external input security to open circuit (TTL
level) security to open circuit (TTL level)
security to open circuit (TTL level) Emergency push button
embeded (cell temperature and emergency)
Power 1,000 W 1,000 W 1,000 W 3,750 WChassis dimensions (W x D x H) 495 x 465 x 280 mm 495 x 465 x 280 mm 495 x 465 x 280 mm 450 x 550 x 133 mm (19 U x 3 U)Chassis weight 24 kg 24 kg 24 kg 24 kgBooster board weight 2 A: 1 kg, 4 A: 0.85 kg, 5 A: 1 kg 10 A: 2 kg, 20 A: 4.2 kg 80 A: 4.8 kg, 100 A: 9 kg N/A
Specifications
Hig
h c
urr
ent
inst
rum
ents
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
Electrical Energy Storage research presents new and challenging technical demands every day. Developments in Batteries, Hydrolyzer or Fuel Cells require leading edge and laboratory proven diagnosis tools for meaningful real world test results.
High current instruments
HCP-803 Highcurrentforsupercapacitorsandfuel cellsTheHCP-803isaHighCurrentPotentiostatcapableofhandling±80Awithavoltagerangeof±3V.Itisprimarilydesignedforapplicationsinthefuelcellandsupercapacitorareas.Itisacombinationofaresearchqualitypotentiostatandan80Aboosterbuiltintothesamechassis.ThepotentiostathasthesamespecificationsastheVMP3potentiostatboards(withEISoption)whennotconnectedtotheboosterportionoftheunit.
HCP-1005 Morepowerforbattery testingTheHCP-1005isacompactHighCurrentPotentiostatspeciallydesignedtostudysecondarybatterieswithahighcapacity.Withavoltagerangeof0.6to5Vandacurrentrangeof±100A,thisunitcanbeusedtotestindustrialLi-ionbatterymodules.TheEIScapabilityintegratedinthechassisisidealforageingtests.TheHCP-1005structureissimilartotheHCP-803.Itisacombinationofaresearchpotentiostatanda100Aboosterbuiltintothesamechassis.
CLB-2000 150A/50Velectronicloadforstack testingTheCLB-2000isa150A/50Vcontrolledelectronicloaddesignedtostudystacksoffuelcellsandsolarcells.TheCLB-2000couplesa2kWelectronicloadwithanEIScapablepotentiostatinthesamecompactchassis.ThisunitcanbeusedinconnectionwithaVMP3toperformsimultaneousmeasurements(ACandDC)onindividualelementsofthestacks(upto30elements).
ELECTROCHEMISTRY INSTRUMENTS20/21
Modules HCP-803 HCP-1005 CLB-2000Batteries/intercalation compoundsSupercapacitorsFuel cellsPhotovoltaic cellsStack of fuel & photovoltaic cellsElectrolysisCoatings
suitable recommanded excellent
PL
UG
- IN
HY
BR I D E L E C T R I C V
EH
I CL
E
mpg
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Hig
h cu
rren
tin
stru
men
tsM
ult
ipo
tent
iost
ats/
galva
nost
ats
Applications
HCP-803 HCP-1005 CLB-2000
FeaturesEIS capability 10 μHz to 15 kHz 10 μHz to 10 kHz 10 μHz to 10 kHzAcquisition time 20 μs 200 μs 200 μsElectrodes connections 2, 3, 4, 5 2, 3, 4, 5 2, 3, 4, 5IR compensation manual, EIS, current interrupt manual, EIS, current interrupt manual, EIS, current interrupt
CurrentMaximum current ±80 A ±100 A -150 ACurrent ranges 7: 10 μA to 80 A 7: 10 μA to 100 A 7: 10 μA to 150 AAccuracy < 160 mA on 80 A range < 200 mA on 100 A range < 750 mA on 150 A rangeBest resolution (meas) 6.4 mA on 80 A range 8 mA on 100 A range 6 mA on 150 A rangeInput impedance 10 MΩ (//20 pA) 10 MΩ (//20 pA) n.a.
VoltageMax applied potential ±3 V 0.6-5.0 V 50 VResolution 5 μV on 200 mV 5 μV on 200 mV 400 μV on 0-50 V rangeAccuracy 10 mV on ±5V range mV on 0-5 V range 50 mV on 0-50 V range
Control amplifierBandwidth with boosters 10 kHz 10 kHz 10 kHzPotentiostat rise/fall time 95 μs 1.7 ms n.a.
GeneralI/O (analog/TTL) 3/2 3/2 3/2Temperature control n.a. with analog I/O With analog I/OTemperature probe n.a. PT100 n.a.Interfaces Ethernet, USB 2.0 Ethernet, USB 2.0 Ethernet, USB 2.0Dimensions (W x D x H) 495 x 465 x 280 mm 495 x 465 x 280 mm 495 x 465 x 280 mmPower requirements 1000 W 1000 W 100 WWeight (chassis + pstats) 23 kg 25 kg 28 kg n.a.: not available
Specification overview
Boo
ster
s
Highcurrentinstruments
Fuelcells Photovoltaicsystems
Applications Supercapacitors Electroplating Battery
Lithium-ion Nickel-Cadmium
Applications Nickel-Metalhydride Battery
Fuelcells Solarcells Photovoltaicsystems Stacksofcells
Applications-SAM-50:voltageadapter(50V)tobeusedwithVMP3
Options
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
MPG-2xx series R&D gradebatteryteststationsTheMPG-2xx seriesisproposedasarangeof5units(infixedconfigurations)withorwithoutEISoneverychannels:-MPG-2: 16channels/100mAeach,-MPG-205: 8channels/5Aeach,-MPG-210: 4channels/10Aeach,-MPG-220: 2channels/20Aeach,-MPG-240: 1channel/40A.
TheMPG-2xx seriescanbeprovidedinarackcapableofsupportingupto5units.OnlyonecomputerisnecessarytocontrolalltheunitsthankstotheEthernetconnection.Withthisconnection,theMPG-2xx seriescanbeinstalledonaLocalAreaNetworktoallowmultipleuserstoaccesstheinstrumentsandfollowthebatterycyclingfromanywhere.TheMPG-2xx seriesoffersatemperaturemeasurementandthreeoptionalconnectionmodestothebattery(batteryholder,shortorlongcables).Eachchannelhastwoanaloginputsandoneanalogoutputtoallowinterfacingwithexternalinstruments.TheMPG-2xx seriesissuppliedwithEC-Lab®software,developedforbatteryandsupercapacitorapplications.Mostofthetechniquesaredesignedspecificallyforbatteries.Specificanalysistoolsarealsoavailable.
ELECTROCHEMISTRY INSTRUMENTS22/23
MPG-2
MPG-205
MPG-210
MPG-220
MPG-240
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
-Currentranging:10µAuptomaxcurrentwitharesolution0.004%oftherange
-0-9Vreferencevoltage-Resolutionof300µVprogrammable
downto5µVbyadjustingthedynamicrange(100µVresolutionon5Vrange)
-Acquisitiontime:200µs-Nolimitintimeanddatarecording
Specifications
Boo
ster
s
Batteryteststations
Hig
h c
urr
ent
inst
rum
ents
Accordingtoyourapplications,yourrequirementsforbattery/supercapacitorinvestigationaredifferent(referenceelectroderequiredornot,sampling,maximumfrequencyforEIS,channelnumber…).
That’swhy,Bio-Logicisofferingseveralsolutiontomeetyourneed.
VMP3/VMP-300ismoreforadvancedmeasurement(researchlevel)andBCS-8xxoffersthestandardofthecyclerwithresearchEISmeasurement.MPG-2xxisasolutionin-between.
Forhigh-throughputmeasurement,BCS-8xx wouldberecommended(upto128channelscanbeputinasinglecabinet).NoteEC-Lab®allowstheusertocontrolseveralVMP3orMPG-2xxinstrumentsfromonesession.
VMP3/VMP-300 MPG-2xx series BCS-8xx seriesCurrent ranges 1 pA - 150 A 10 μA to 40 A 10 μA – 120 AVoltage range ±10 V -2;9 V 0;9 VEIS frequency range 7 MHz – 10 μHz 20 kHz – 10 μHz 10 kHz-10 mHzIn-built EIS Yes on each channel Yes on each channel Yes on each moduleAcquisition time 200 μs/1μs with LSG option 200 μs 2 msElectrode connection 2,3-electrode/4-points
measurement with CE measurement
2-electrode/4-points measurement3-electrode/5-points on MPG-2
2-electrode/4-points measurement
HPC measurement Yes. Down to 6 ppm Yes. Down to 6.3 ppm Yes. Down to 6 ppmMax Channel number 16 16 128Application High end research Research development High-throughput battery/material
screening
Specification overview
Options-EIS-Rack(5units)-Short(25cm)orlongcables(2.5m)-Temperatureprobe-BH-1iBatteryHolder
Sof
twar
e
pack
age
Fuel
cel
l te
st s
tatio
nsM
ater
ials
& li
quid
s te
st s
yste
ms
Sca
nn
ing
sy
stem
s
ELECTROCHEMISTRY INSTRUMENTS24/25
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
atte
ry
test
sta
tions
-HighqualityEIS:Fullscanfrom10kHzto10mHz-18-bitA/Dconverter(40µVresolution)-HPCmeasurementdownto6.3ppm-ModularityfromfewµAto120A-Voltagemeasurementfrom0Vto9V-Modulemixing(BCS-805/810/815)-Powerfulinterface-2msacquisitiontime-Severalcabinetsizes-Plugandplaymoduleinstallation
Specifications
m
easurementEIS
Boo
ster
s
Batterycyclers
Hig
h c
urr
ent
inst
rum
ents
BCS-8xx seriesBatterycyclingteststations
EachBCS-8xxmoduleiscomposedof8channels.
Toensurebetteraccuracyincurrentcontrolandmeasurement,5 current rangesareavailabledependingonthemodel.
ChannelsofBCS-815modulescanbeconnectedinparalleltoincreasethemaximumcurrentupto120 A.
Withan18-bitanalogtodigitalconverterforthevoltagemeasurement,theresolutionoftheBCS-8xx isanimpressive40 µV.
Toaddevenmorecapabilityandvalue,everychannelinamoduleisEIS-capableoverafrequencyrangefrom10 kHz to 10 mHzforaccurateandfastdeterminationofthebatteryinternalresistance.
BCS-8xxmodulescanbeaddedtoasinglecabinet.Severalsizesareoffered(38U,24U,12Uand6U).
Connection:-Cellcablefrom25cmto10m-CCH-1xxCoincellholder-BH-1iCylindricalbatteryholder-CC8Currentcollectortosetparallelmode(upto±120A).-CCH-88positionscoincellholder
Cabinet:-Rollingcabinet(38U,24U)-Benchtopcabinet(12U,6U)
Options
Impedance measurement for battery testing, why...?
BCS-8xx series,withitsfastbandwidthcontrollers,offersbothpotentio-andgalvano-controlforEISmeasurementsin10 kHz to 10 mHzfrequencyrange,withuser-specifiednumberofdatapointsandfrequencyrangetoberecorded.Userisalsoincontroloftheexcitationamplitude.Impedancespectroscopycanbeusedasastandalonetechnique,butitcanbealsoseamlesslyincorporatedintoourModuloBattechniquetorecordtheimpedancespectrumofthebattery,eitherinequilibriumorsteady-stateconditions.Thatmeansyounotonlycanrecordaspectrumofthecellataconstantvoltage,butalsounderagivengalvanostaticload.
Iftherearesourcesofuncompensated inductanceorcapacitanceinthecell,onlyfullimpedancespectrumcanbeareliablemeasureorinternalresistancethroughanautomatedspectrumfittingprocedure.
LowfrequencyrangeofthespectrumisaninvaluablesourceofinformationaboutLi+ diffusionwithintheelectrolyte(separator),aswellasporositywithinelectrodesandinsidetheactivematerialparticles..
18-bit resolutionallowsrecordingsmall-amplitudeEISontopofsubstantialDCcurrentswithverygoodaccuracy.
Highfrequency Lowfrequency
Diffusionprocess
Internalresistance
Inductionbehavior
Sof
twar
e
pack
age
Fuel
cel
l te
st s
tatio
nsM
ater
ials
& li
quid
s te
st s
yste
ms
Sca
nn
ing
sy
stem
s
ELECTROCHEMISTRY INSTRUMENTS26/27
AcomprehensivesoftwarepackageEC-Lab®isanadvancedsoftwarepackageforperformingelectrochemistrymeasurements,whereasBT-Lab®isdedicatedtobatterycyclingsystem(BCS-8xxseries).Withmorethan15yearsofdevelopmentandconstantimprovementintechniquesandfeatures,EC-Lab®softwarehasbecomethebenchmarkinpotentiostatcontrolsoftware.
DisplaymodeTwoviewmodesareavailableinEC-Lab® /BT-Lab®.Thesetupofexperimentscanbedonewithatechniquemenu,orbyinputtingparametervaluesintoaspreadsheet.Mostoftheexperimentalparameterscanbemodified“onthefly”duringtheexperiment,withthechangesstoredintotherawdatafile.Theappearanceofthesoftwareinterfaceisadjustabletocreatethebestworkingenvironmentfortheuser.
ExperimentalsequencebuilderEC-Lab®softwarecontainsmorethan80techniques.Thesetechniquescanaddressapplicationsinvoltammetry,EIS,corrosionandenergysourcedevelopment.Apowerfultechniquebuildercanexecuteaseriesofdifferentmodulartechniques,waitandloopfeaturestocreatecomplexexperimentalsequences.Evenwithineachtechnique,theusercancreateupto100linkablesequencesofthatexperimentwithdifferentparameters.Whenacertainleveloftheexperimentisreached,anemailcanbesenttotheuser.
EISmeasurementsEISmeasurementscanbemadeinbothcontrolledpotentialandcontrolledcurrentmodesfrom10µHztoaremarkable7MHz.Thepatented“driftcorrection”algorithmandmultiplestabilityparametersallowuserstoacquirehighqualitydatafromtheirEISmeasurements(moreinformationinpage22).
Display…EC-Lab®’sgraphicpackageprovidedwiththesoftwareincludesapowerful3-Dimensionplotfeatureandatooltocreateuniquegraphtemplates.Usingouradvanced“Process”function,theusercancreatenewvariablesforeachaxis.Thisenablesmathematicalfunctionstobeperformedondataplottedonanyaxis(x,y1andy2).
…fitting…Powerfulelectro-analyticalanalysistools(suchaspeakfind/height,convectionwave,integral,Tafelfit,Rpdetermination)areavailableinEC-Lab®.Theseanalysesincorporateclassicalfitroutines(linear,polynomial,multi-exponential)andalgorithms.Alltheanalysisresultsarestoredinaseparatefile.EC-Lab®’sEISmodelingpackage,ZFit,utilizestheequivalentcircuitapproach.Thereareover150standardcircuitsandtwominimizationsalgorithmsavailableforuseinunderstandingimpedanceplotinformation.Theusercandefineandbuildhisowncircuitmodelusingarangeofthirteensimpleelements(R,C,L,Q,W,G,Wd,M,Ga,Gb,La,Ma,Mq).Thelastelementscanbeassimilatedtoatransmissionlines.Abatchprocessingfeatureallowsthefittingofmultiplecyclesinanimpedanceexperiment.
…&simulationSeveraltoolsareavailabletosimulateCVcurve,TafelplotorEISdata.Theycanbeusedastrainingtools.CVSimallowtheusertocreatedatawithdifferentmechanismssuchassingle(E)ormulti(uptoEEEEE)electrontransfer.ElectrontransferreactioncanalsobemixedwithchemicalreactionelectrontransfertosimulateanECmechanism.
EC-Lab® graphicsAn extended range of analysis
Log (<I>/mA)-1-2-3-4-5-6
E we/V
0-0.1
-0.2-0.3
-0.4-0.5
-0.6
EC-Lab® /BT-Lab®
Powerfulandcomprehensiveadvancedsoftware
Impedance spectroscopy
General electrochemistry
Electro-analytical
Corrosion
Battery
Super-capacitor
Fuel cell
Photovoltaic cell
Ewe/V0.60.40.20-0.2
<I>/
mA
0.8
0.6
0.4
0.2
0
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sS
oftw
are
pa
ckag
e
PeakAnalysis...
CVFit...
WaveAnalysis...
General electochemistry
RPFit...
ElectrochemicalNoise...
CorrSim...
CASPFit...
VASPFit...
TafelFit...
Corrosion
Mott-Schottky...
ZFit...
Kramers-Kronig...
ZSim...
EIS
Processdata(capacity,efficiency,energy...)
Battery process
Photovoltaicanalysis(fillfactor,efficiency...)
Photovoltaic
LinearInterpolation...
Integral...
SubtractFiles...
LineFit...
PolynomialFit...
MinMax...
Multi-ExponentialFit...
Filter...
FourierTransform...
Math
Re(Z)/Ohm 40 01
23020
10
-Im(Z
)/Ohm
151050
Time/h
Singlepotentiostats/galvanostats:SP-50,SP-150,SP-200,SP-240,SP-300Multipotentiostats/galvanostats:VMP-300,VSP,VMP3,VSP-300Highcurrentpotentiostats/galvanostats:HCP-803,HCP-1005,CLB-2000Batteryteststations:MPG2,MPG-205,MPG-210,MPG-220,MPG-240
EC-Lab® provided with...
Boo
ster
s
Softwarepackage
Bat
tery
te
sts
tatio
nsH
igh
cu
rren
t in
stru
men
ts
Batterycyclingsystems:BCS-805,BCS-810,BCS-815
BT-Lab® provided with...
Fuel
cel
l te
st s
tatio
nsM
ater
ials
& li
quid
s te
st s
yste
ms
Sca
nn
ing
sy
stem
s
-0,208 -0,0325 0,142 0,317 0,492 0,667
1,42
0,76
0,11
-0,54
-1,19
E/V
Curr
ent/m
A
ELECTROCHEMISTRY INSTRUMENTS28/29
UiEChem™:-CyclicVoltammetry,-LinearSweepVoltammetry,-Chronoamperometry,-Chronopotentiometry,-ChronoOCV,-Chronoauxiliarypotential,-SquareWaveVoltammetry,-NormalPulseVoltammetry,-DifferentialPulseVoltammetry
UiECorr™:-EcorrvsTime,-LinearPolarizationResistance,-TafelPlot,-PotentiostaticPolarization,-GalvanostaticPolarization,-PotentiodynamicPolarization,-ZeroResistanceAmmetry
UiEChem™/UiECorr™ TheUiEChem™/UiECorr™softwaresuppliedwiththePG-581,BiStat3200,SensorStat,isacomprehensiveandfullyfeaturedpackagewhichencompassesawideselectionofstandardelectrochemicaltechniques.Allthisiscombinedwithaneasy-to-usegraphicsinterface.Afteratechniquehasbeenselectedawaveformdiagramisdisplayedshowingthestructureoftheexperiment.Atthesametimetheusercanenterintheexperimentalparameters,setthesamplingrate,numberofcyclesandcurrentautoranging.Thesoftwareautomaticallyconfiguresitselftothenumberofpotentiostatchannelsinstalledintheunit.
AutosequencingTheUiEChem™/UiECorr™softwareprovidesaflexible,intuitiveinterfaceforrunningmultipleexperimentsinauser-definedsequence.Oncethesequenceisstartedtheexperimentsarerunautomatically,one-at-a-time,intheorderinwhichtheyappearinthesequence.
Graphicdisplay&analysisAstandardgraphicsdisplayisprovidedforeachtechniqueandwehaveaddedtheabilityfortheusertodefinetheirpreferredformatforeachtechniquefromasimpletemplate.TheUiEChem™softwarefeaturesapeakanalysisroutinewhichiseasytouse.
AdvancedwaveformgenerationTheinstrumentsarecapableofgeneratingcomplexandrepetitivewaveformswithprecisiontiming.Theinstrumenthasasequencedwaveformgeneratorwhichgenerateswaveformsbasedonasequenceofsteps.Eachstepmaycompriseawaveformwhichincludespulses,linearsweepsandarbitrarywaves.
Electrochemical Impedance Spectroscopy Built-in EIS capabilitywithequivalentcircuitfitting
MeasurementsManyunitsintheelectrochemistryproductrangedevelopedbyBio-Logiccanbeequippedwithabuilt-inEISanalyzer.ThismeasurementisbasedontheDSPtechnologythatmixesaccuracyandfastsampling.Thisfeatureresultsinseveralmajortoolsdevelopedinourcontrolsoftware:singlesineandmultisineEIStechniques,FastFourierTransform(FFT)basedintegration,cycleaveragingupto16frequenciesandapatenteddriftcorrection.
ControllingtechniquesACsinewavescanbesuperimposedonaDCpotentialoraDCcurrentvalue.Additionaltechniquesareavailablethatimposethesinewaveonapotential(SPEIS,alsoknownasMottSchottkytechnique)oracurrent(SGEIS)sweep.FinallyourEIStechniquescanbesequencedtoapplydifferentdefinedconditionsduringthefrequencysweep.
AccuracyAccuracyisgivenbytheerrorobservedonthephaseandonthemagnitude.Foralmostallofourpotentiostats,wespecify1%,1°accuracybelow500kHz,whichisreducedwithabooster.ForSP-200/300technology,theperformanceishigherandreaches0.3%,0.3°accuracyinthesamearea.
ModelingEC-Lab®softwareoffersZFit,amodelingtoolforequivalentcircuitfitting.Over150standardcircuitscombining13elementsandtwominimizationalgorithms(SimplexDownHillandLevenberg-Marquardt)areavailabletoinvestigateimpedancedata.ZFitandZSimtoolsareavailableinEC-Lab®demoversion.
1e+9
3% 3° 1pF
Frequency (Hz)
|Z| (
Ohm
)
1% 1°0.3% 0.3°
1e+8
1e+7
1e+6
1e+5
1e+5
1e+3
1e+2
1e+1
11e-1
1e-2
1e-3
101 100 1e+3 10e+3 100e+3 1e+6 10e+6
-0.184 0.008 0.2 0.392 0.584
-31.76-42.18
-21.34-10.91
0
E/V
Curr
ent/m
A
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
s
EIScontourplotofSP-300withstandardcable
Singlepotentiostats/galvanostats: PG-581Multipotentiostats/galvanostats: BiStat3200,SensorStat
Provided with...
Boo
ster
s
Softwarepackage
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eH
igh
cu
rren
t in
stru
men
tsFu
el c
ell
test
sta
tions
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
ELECTROCHEMISTRY INSTRUMENTS30/31
FCT seriesTwomodelsfor 25 and 50 cm²PEMFC
TheFCT-50S/ZandFCT-150S/ZarecompactfuelcellteststationsdesignedforPEMFC(ProtonExchangeMembraneFuelCell)testing.Basedonfeedbackfromourcustomers,theyaredesignedtobethemostflexibleteststationsonthemarket.Thecompactchassisintegratesaprogrammableelectronicload(250W),gasandwatercontrolcircuitry(flow,pressureandtemperature)anddataacquisition.Theelectronicloadusesstate-of-the-arttechnologyandiscapableofreachingverylowvoltagelevels(virtually0V)at150A(forFCT-150S/Z)and50A(forFCT-50S/Z).Anumberofsafetyfeatureshavebeenincorporatedinthehardwareandsoftware.Toconductlong-termexperiments,suchasfuelcellageing,Bio-Logichasdevelopedanautomatedhumidifier,waterfillingandcondenserwaterpurging,allmanagedbyFC-Labcontrolsoftware.
FC-LabPowerfulmonitoringsoftwareFC-Labistheoperatingsoftwareusedtocontrolandanalyzedatafromtheinstrument.Withaneasy-to-useinterface,itoffersallcontrolsandfunctionsforfuelcelltestingwithindividuallytabbedmenus.Thegraphicfunctionsofferareal-timedisplayofperformanceofthefuelcellwithrespecttoeachofthemeasuredorcontrolledvariables.DatacanbeanalyzedbyEC-Lab®fittingtools(ZFit...).
Re(Z)/mOhm10080604020
-Im(Z
)/mOh
m
40
30
20
10
0
-10
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sFu
el c
ell
test
sta
tions
Boo
ster
s
SpecificationsFCT-50S/Z FCT-150S/Z
Max current 50 A 150 AMax voltage 5 V 5 VElectronic Load 250 W 250 WMinimum load resistor 0.7 mΩ 0.7 mΩBuilt-in EIS analyzer 10 μHz up to 10 kHz 10 μHz up to 10 kHzCurrent measurement accuracy 0.5% FSR 0.5% FSRCurrent resolution 4 mA 11 mAPotential resolution 76 μV 76 μVFuel gas flow control 0 - 40 L/h 0 -120 L/hOxidant gas flow control 0 -100 L/h 0 - 300 L/hBack pressure control 0 - 5 bars 0 - 5 bars5 temperature control cell, humidifiers, heaters cell, humidifiers, heatersInterfaces Ethernet EthernetSafety Alarms with automatic N2 purge under voltage,
over current, over temperature, over water
under voltage, over current, over temperature, over water
SpecificationsFC-Lab
Gas control and display independent for each cell and each gas
temperatures, pressures, flows
Facilities
current density display,on the fly parameter changes,multivariable graphic display
Loal Control
galvanostatic/galvanodynamic,potentiostatic/potentiodynamic,power/load
Techniques
open circuit voltage,voltage pulses,current pulses,voltage scan,current scan,potentio EIS,galvano EIS,constant load discharge,constant power discharge,macrotechniques (SGEIS, SPEIS),loop
Analysis EC-Lab®
Fuelcellteststations
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
Hig
h c
urr
ent
inst
rum
ents
PEMFCdevelopmentandtesting Singlecellorsmallstacks
Applications
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
ELECTROCHEMISTRY INSTRUMENTS32/33
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
sB
oost
ers
Impedanceanalyzer
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eH
igh
cu
rren
t in
stru
men
ts
Conductivitymeter
MTZ-35 35MHzImpedanceAnalyzerMTZ-35isanimpedanceanalyzerdedicatedtomaterialcharacterizationoverthefrequency10 µHz to 35 MHz.TheMTZ-35canbecoupledwiththeHighTemperatureFurnaceHTF-1100andtheIntermediateTemperatureSystemITSinordertoinvestigatematerialspropertiesoverawidetemperaturerange(-40 °C to 1100°C).Twomainsampleholdersareproposed:HTSH-1100forhightemperatureuseandCESHforambienttemperatureusewithmaximumtemperatureof150°C.
MCS 10 FullyIntegratedMultichannelConductivitySpectroscopyMCS 10isamultichannelconductivityspectrometerdedicatedtostudyionic liquids and liquid electrolytesoverawidetemperaturerange.
TheConductimetrysystemcanaccommodateup to 10 cellsandworksinthetemperaturerangefrom-40 °C to +150 °Cwithahighaccuracylevelof±0.2°C.AnEIS diagram(NyquistandBode)canbedisplayedforeachmeasurementpoint.
Specifications
Ceramics Sensors Polymers Nanomaterials Solar/photovoltaiccells Rubbers Glues Epoxies Liquidcrystals Biologicalcells Polarliquids....
Applications
Furnace and sample holdersHTSH-1100 CESHonitsbase
Ionicliquidstudy Organicelectrolytestudy Liquidconductimetry
Applications
Generator
Frequencyrange Frequency Range: 10 μHz to 35 MHzVoltagerangeDC ±100 μV to ±10 V VoltagerangeAC 100 μV to 10 V Measurement ranges
Inductance 10 nH to 10 kHCapacitance 1 pF to 1000 μFResistance 1 mΩ to 500 MΩBasicaccuracy 0.1%
Product model name / part number Operating temperature FeaturesFurnace HTF-1100: 097-110 RT to 1100 °C Heating rate adjustable
K-type thermocoupleHigh Temperature Sample Holder (HTSH-1100)
Ф=03 mm: 097-130/SФ=06 mm: 097-131/SФ=12 mm: 097-132/SФ=25 mm: 097-133/S
RT to 1100°C Quartz tube for controlled atmosphereLeak-tight up to 2 bar relativeK-type thermocouple
Controlled Environmental Sample Holder (CESH)
In-plane: 097-150/1Through-plane: 097-150/2
-40 to 150 °C Leak-tight up to 2 bar relative
Intermediate Temperature System (ITS)
In-plane: 097-140/11Through-plane: 097-140/12
-35 to 150 °C Temperature accuracy: 0.3 °CPT1000 probes
HTF-1100
Fuel
cel
l te
st s
tatio
nsM
ater
ials
& li
quid
s te
st s
yste
ms
Sca
nn
ing
sy
stem
s
SpecificationsMCM 10
Conductivityranges 76 ranges from 0.2 μS/cm, to 0.2 S/cmConductivityaccuracy <4 % of the 2 μS/cm
<2 % of the 20 μS/cm and the 0.2 S/cm range<1 % of all other ranges
WTSH 10
Temperaturerange -40 °C to +150 °CTemperatureAccuracy(typ.) ± 0.1 °CNumberofslots 10ExternalDimension 290 x 340 x 375 mm (W x D x H)HTCC
Celltype Parallel plates platinized platinum on glass holderConnections 2-wire connectionsCellfactor K = 1 (nominal)Minimalsamplevolume 0.5 - 1.0 mL
TheMCS10consistsofthreeintegratedcomponents:
MCM 10:FRA-basedimpedanceanalyzerwithtenchannelsWTSH 10:WideTemperatureSampleHolderwithtenslotsHTCC:HighTemperatureConductivityCells–Platinized/
PtParallelPlateElectrode
ITS
Scanning techniques Information Resolution ApplicationsSECM Scanning ElectroChemical
Microscopyreactivity probe size bio electrochemistry,
corrosion, fuel cells, batteries, catalysts
ac-SECM alternating current Scanning ElectroChemical Microscopy
topography or reactivity (no mediator required)
probe size bio electrochemistry, corrosion, fuel cells, batteries, catalysts
ic-SECM intermittent contact Scanning ElectroChemical Microscopy
topography and reactivity
probe size bio electrochemistry, corrosion, fuel cells, batteries, catalysts
LEIS Localised Electrochemical Impedance Spectroscopy
local impedance of the sample
tens of μm corrosion, coatings, catalysts
SVP (SVET) Scanning Vibrating Electrode Technique
electrochemical activity 10-15 μm corrosion, coatings, catalysts
SDS Scanning Droplet System dc electrochemistry in a droplet of electrolyte
hundreds of μm
corrosion, coatings
ac-SDS alternating current Scanning Droplet System
impedance in a droplet of electrolyte
hundreds of μm
corrosion, coatings
SKP Scanning Kelvin Probe work function difference / topography
probe size corrosion, coatings, semi-conductors, catalysts
OSP Optical Surface Profiler topography 20 nm any field
ELECTROCHEMISTRY INSTRUMENTS34/35
Modularsystems fortheelectrochemistry at the local scale
SECMareascan
Sin
gle
po
tent
iost
ats/
galva
nost
ats
Mu
lti
pote
ntio
stat
s/ga
lvano
stat
s
Thepotentiostat/galvanostatgiveanaverageresponseoftheelectrodematerialanditisconsideredthatitishomogeneous.However,foroptimizationpurposes,itmightbeinterestingtoconfirmthishomogeneityandtostudythespatialdependenceoftheelectrodeproperties.Ourlocalelectrochemistryplatformisamodularsystemthatcanincludeupto9techniques.Thetablebelowsummarizesthetechniques,thetypeofinformationthatcanbeobtained,thesmallestsizeofthefeaturesthatcanbedetectedandthetypicalapplications.
Awidevarietyofoptionalaccessoriesarealsoavailable,includingvariousprobeoptions,celloptions(environmentalTriCell™andµTriCell™),longworkingdistanceopticalvideomicroscope(VCAM3)and3Dshadedsurfacerenderingsoftware(3DIsoPlot™).
Tools
57
46
-0.75
0.73
0.00
mm
µm
mm
1.80
M470M470isthe4thgenerationofscanningprobesystems,whichincludesahigh-resolutionscanningstageandadditionalprobetechniques.TheM470achievestheperfectbalanceofscanspeed,resolutionandaccuracytodeliveranewstandardinspatiallyresolvedelectrochemicalmeasurements.Thefastpreciseclosedlooppositioningsystemisdesignedspecificallyforthedemandsofscanningprobeelectrochemistrywithnanometerresolution.
9availabletechniques-SECM-ac-SECM-ic-SECM
-LEIS-SVET-SDS
-ac-SDS-SKP-OSP
Ultra high resolution scanning stagewithadditionaltechniques
M370 TheM370isamodularconfigurablesystemwhichwillperformallthekeyscanningprobeelectrochemicaltechniquesandlaser-basednon-contactsurfaceprofiling.TheM370isavailableinanyorallofthesixconfigurations(SECM,SVET,SKP,LEIS,SDS,OSP)andmaybeupgradedatalaterdatebysubsequentpurchaseofanycombinationoftheavailabletechniques.
6availabletechniques-SECM-LEIS
-SVET-SDS
-SKP-OSP
Versatilityandprecision
SpecificationsM470 M370
Number of techniques 9 techniques 6 techniquesPositioning resolution 20 nm 100 nmScanning range 110 mm 70 mmMax. scan speed 10 mm/s 2 mm/sPiezo positioning yes n.a.Potential range ±10 V ±2 VCurrent ranges 1 A to 1 pA 20 mA to 1 nAAnalog to digital converter resolution 24-bit 16-bitImpedance ability up to 1 MHz n.a.n.a.: not available
Boo
ster
s
Scanningsystems
Bat
tery
te
sts
tatio
nsS
oftw
are
pa
ckag
eFu
el c
ell
test
sta
tions
M470 and SP-300 are now compatibleM470isnowavailablewithachoiceofpotentiostats/galvanostats/FRAs.BoththehigherspecificationSP-300standalonepotentiostat/galvanostat/FRAandtheoriginalmodel3300,integratedintotheM470chassis,arenowsupported.SelectingtheSP-300optionoffersfurtherdccurrentmeasurementsensitivityandincreasedEISbandwidth.CurrentSP-300 ownershavetheoptionofpurchasingtheM470systemwithahardwareinterfacetoconnecttheirexistingsystem.TheSP-300hardwareinterfacemoduleplugsdirectlyintotheM470modularchassisandprovidesalltherequiredconnectionstointerfacetheanaloguesignals,andcontrolfunctionalityrequiredbythesystem.TofacilitatemountingoftheSP-300lowcurrentamplifierslocallytothescanningprobecellconnections,adjustablestandsandbracketsareprovidedwhichmountdirectlytotheM470baseplate.TherequiredSP-300configurationisoneortwochannelboardswithimpedanceabilityandultralowcurrentoptions.
Hig
h c
urr
ent
inst
rum
ents
Stand for ease of use
hardware interface
22
11
0.75-0.751.50
mm
nA
mm
0.00
OSPareascan
23
12
-3.753.65
mm
0
10
kΩ c
m²
mm
LEISareascan
Mat
eria
ls &
liqu
ids
test
sys
tem
sS
can
nin
g
syst
ems
Sales&technicalcontacts
BioLogicScienceInstrumentsispresentinmostcountriesthroughanextensivedistributionnetworkHeadquartersBio-Logic SAS4, rue de Vaucanson - 38 170 Seyssinet-ParisetFrancePhone: +33 476 98 68 31 Fax: +33 476 98 69 09
Affiliate officesBio-Logic USA, LLCP.O.Box 30009 - 37 930 Knoxville USAPhone: +1 865 769 3800Fax: +1 865 769 3801
Bio-Logic Science Instruments Pvt Ltd304,Orion Business Park, G. B. Road, Thane(W), 400 607 Mumbai IndiaPhone: +91 222 584 2128Bio-Logic Middle EastDMCC Office - No. 1206, Indigo Icon Tower, Cluster F, Dubai JLTUnited Arab emiratesPhone: +971 455 151 82Fax: +971 455 151 63
www.bio-logic.net
Broc
hure
rele
ased
on
july
201
5 - S
peci
ficat
ions
and
pic
ture
s sub
ject
to ch
ange
..