Electricity Act 1992 plus amendments

Electricity Regulations 2003

• AS/NZS 3000 wiring rules

• AS/NZS 3760: 2003 Inservice Safety Insp. & test.

• AS/ NZS 3012:2003 Con. & Demo sites.

Legislation

Page 2: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Reg. 76(B) – AS/NZS 3760:2003Inservice Safety Inspection & testing Electrical Equipment

Reg. 69(B)(d) – AS/NZS 3012:2003Electrical installations – Construction & demolition sites.

Electricity Regulations

Page 3: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

AS/NZS 3012:2003

Applies to all construction & demolition sites.

Standard

Page 4: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Key points - AS/NZS 3012:2003

• Support of cables entering switchboards –’flexible’.

• All final sub-circuits protected by 30mA RCD’s.

• Construction wiring must be separate to perm wiring.

• Minimum flexible cord size 1.00mm2

• Leads – Protect from mechanical damage.

– Supported off the floor.

Page 5: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Lighting

Festoon lamps

• Lampholder permanently moulded to cable.

• Non-conductive, mechanical guard.

• Supported at least 2.5m from the floor.

Page 6: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Lighting - portable

Portable lamps

Must have a rating of IP2X or higher.

Page 7: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Inspections

• Prior to initial service

• Where new, supplier to test & tag.

• Before return to service after servicing or repair.

• Can use an individual tag or register.

• Competent person can carry out testing & tagging.

• Only a registered person with a current practicing license can

carry out electrical repairs.

Testing & Tagging

Page 8: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Testing & Tagging

Table 2

• 3 Monthly – Portable equipment.

• RCD’s – trip test daily before use. (portable gear)

– monthly (fixed).

• RCD’s testing every:

– 3 months portable.

– 12 months fixed.

Page 9: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Testing & Tagging

Sheds & switchboards.

Require Certificate of compliance on

completion of installation.

Page 10: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Testing & Tagging - continued

• Testing & tagging – visual inspections.

• All electrical devices made to AS/NZS 3105 do not comply with AS/NZS 3012:2003.

Page 11: Electricity Act 1992 plus amendments Electricity Regulations 2003 AS/NZS 3000 wiring rules AS/NZS 3760: 2003 Inservice Safety Insp. & test. AS/ NZS 3012:2003

Testing & Tagging - continued

CompliancePlug boxes

• Jackson (comply)

• PDL (comply)

• Others do not currently comply with AS/NZS 2012. (domestic plug boxes)