12
VALVOLE ELETTRICHE ELECTRICAL VALVES Valvole elettriche in cavità SAE a tenuta singola e dop- pia e a cursore. Bobine e connettori. Solenoid valves in SAE cavities single or double sealing or spool type. Coils and connectors.

ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

VALVOLE ELETTRICHEELECTRICAL VALVES

Valvole elettriche in cavità SAE a tenuta singola e dop-pia e a cursore. Bobine e connettori.

Solenoid valves in SAE cavities single or double sealing or spool type. Coils and connectors.

Page 2: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

120 I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

Aggiornamento - Update 20N-2020

VALVES & SOLUTIONS

0 1,25 2,5 3,75 5 6,25

0

45

90

135

180

225

0 5 10 15 20 250

3

6

9

12

15[bar]

[USgpm]

[l/min]

[PSI] 1 2

PERFORMANCES

26,

2 5

9

12,7

3/4-16UNF-2A

24

2 (1.0

3)

(0.50)

EMERGENZA A SVITARE(2

.32)

(Unscrew emergency)

1

VALVOLE A COMANDO ELETTRICO SAE8 2 VIE/2 POSIZIONI DIRETTE2 WAYS/2 POSITIONS SAE8 ELECTRIC VALVES - DIRECT ACTING EV6

01 VALVOLE A COMANDO ELETTRICO SAE8 2 VIE/2 POSIZIONI DIRETTE(2 WAYS/2 POSITIONS SAE8 ELECTRIC VALVES - DIRECT ACTING) EV

02 SCHEMA(CIRCUIT)

Normalmente chiusa(Normally closed)

C6

Normalmente chiusa + emergenza(Normally closed + emergency)

E6

Normalmente aperta(Normally open)

A6

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EV6 3/4-16UNF-2A 22 (5.8) 210 (3045) 0,12 (0.26) 30 (22) SAE 8/2

01 02

EV

BOBINA 18 W E CONNETTORE VEDI PG. 129-130

18 W COIL AND CONNECTOR SEE PG. 129-130

1

2

1

2

1

2EVC6 EVA6 EVE6

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 0,25 cm3/min - 5 gocce/min Max leakage 0,015 in3/min - 5 drops/min

Page 3: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Aggiornamento - Update 20N-2020

I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

VALVES & SOLUTIONS

121

0 1,25 2,5 3,75 5 6,25

0

45

90

135

180

225

0 5 10 15 20 250

3

6

9

12

15[bar]

[USgpm]

[l/min]

[PSI]1 2

PERFORMANCES

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a sup-ply voltage 10% below the nominal value.

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)

Pressione maxMax pressure

bar/PSI

PRESSIONE MAX (bar)MAX PRESSURE (PSI)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EDE6 3/4-16UNF-2A 22 (5.8) 210 (3045) 0,13 (0.28) 30 (22) SAE 8/2

VALVOLE A COMANDO ELETTRICO SAE8 DOPPIA TENUTA 2 VIE/2 POSIZIONI DIRETTE2 WAYS/2 POSITIONS SAE8 DOUBLE SEALING ELECTRIC VALVES - DIRECT ACTINGED6

01 02

ED E6

1

2EDE6

01

VALVOLE A COMANDO ELETTRICO SAE8 DOPPIA TENUTA 2 VIE/2 POSIZIONI DIRETTE

(2 WAYS/2 POSITIONS SAE8 DOUBLE SEALINGELECTRIC VALVES - DIRECT ACTING)

ED

02 SCHEMA(CIRCUIT)

Normalmente chiusa + emergenza(Normally closed + emergency)

E6

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 0,25 cm3/min - 5 gocce/min Max leakage 0,015 in3/min - 5 drops/min

27

66,

7

12,7

3/4-16UNF-2A

EMERGENZA A PULSANTE

24

2

(Push emergency)

(2.6

3)(1

.06)

(0.50)

1

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

Page 4: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

122 I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

Aggiornamento - Update 20N-2020

VALVES & SOLUTIONS

0 2,5 5 7,5 10

0

30

60

90

120

150

0 10 20 30 400

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]1 2

PERFORMANCES

12,7

3/4-16UNF-2A

27,

6 7

1,2

24

EMERGENZA A SVITARE(Unscrew emergency)

1

2

(0.50)

(1.0

9)(2

.80)

VALVOLE A COMANDO ELETTRICO SAE8 2 VIE/2 POSIZIONI PILOTATE2 WAYS/2 POSITIONS SAE8 ELECTRIC VALVES - PILOT OPERATEDEV7

01 VALVOLE A COMANDO ELETTRICO SAE8 2 VIE/2 POSIZIONI PILOTATE(2 WAYS/2 POSITIONS SAE8 ELECTRIC VALVES - PILOT OPERATED) EV

02SCHEMA(CIRCUIT)

Normalmente chiusa(Normally closed)

C7

Normalmente chiusa + emergenza(Normally closed + emergency)

E7

Normalmente aperta(Normally open)

A7

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EV7 3/4-16UNF-2A 40 (10.8) 350 (5075) 0,16 (0.35) 30 (22) SAE 8/2

01 02

EV

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

1

2

1

2

1

2EVC7 EVA7 EVE7

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)Trafilamento massimo 0,25 cm3/min - 5 gocce/min Max leakage 0,015 in3/min - 5 drops/min

Page 5: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Aggiornamento - Update 20N-2020

I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

VALVES & SOLUTIONS

123

0 2,5 5 7,5 10

0

30

60

90

120

150

0 10 20 30 400

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]

2→1

1→2

EVC8-EVE8

0 2,5 5 7,5 10

0

30

60

90

120

150

0 10 20 30 400

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]

2→1

1→2

EVA8

PERFORMANCES

12,7

3/4-16UNF-2A

27,

6 7

1,2

24

EMERGENZA A SVITARE(Unscrew emergency)

1

2

(0.50)

(1.0

9)(2

.80)

01 VALVOLE A COMANDO ELETTRICO SAE8 2 VIE/2 POSIZIONI PILOTATE(2 WAYS/2 POSITIONS SAE8 ELECTRIC VALVES - PILOT OPERATED) EV

02 SCHEMA(CIRCUIT)

Normalmente chiusa(Normally closed)

C8

Normalmente chiusa + emergenza(Normally closed + emergency)

E8

Normalmente aperta(Normally open)

A8

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EV8 3/4-16UNF-2A 40 (10.8) 350 (5075) 0,16 (0.35) 30 (22) SAE 8/2

VALVOLE A COMANDO ELETTRICO SAE8 2 VIE/2 POSIZIONI PILOTATE2 WAYS/2 POSITIONS SAE8 ELECTRIC VALVES - PILOT OPERATEDEV8

01 02

EV

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

1

2

1

2

1

2EVC8 EVA8 EVE8

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 0,25 cm3/min - 5 gocce/min Max leakage 0,015 in3/min - 5 drops/min

Page 6: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

124 I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

Aggiornamento - Update 20N-2020

VALVES & SOLUTIONS

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIO (Nm)TIGHTENING TORQUE (lbt ft)

CAVITÀCAVITY

ED9 3/4-16UNF-2A 40 (10.8) 350 (5075) 0,16 (0.35) 30 (22) SAE 8/2

VALVOLE A COMANDO ELETTRICO SAE8 DOPPIA TENUTA 2 VIE/2 POSIZIONI PILOTATE2 WAYS/2 POSITIONS SAE8 DOUBLE SEALING ELECTRIC VALVES - PILOT OPERATEDED9

01

VALVOLE A COMANDO ELETTRICO SAE8DOPPIA TENUTA 2 VIE/2 POSIZIONI PILOTATE

(2 WAYS/2 POSITIONS SAE8 DOUBLE SEALINGELECTRIC VALVES - PILOT OPERATED)

ED

02SCHEMA

(CIRCUIT)

Normalmente chiusa(Normally closed)

C9

Normalmente chiusa + emergenza(Normally closed + emergency)

E9

Normalmente aperta(Normally open)

A9

0 2,5 5 7,5 10

0

30

60

90

120

150

0 10 20 30 400

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]

2→1

1→2

EDC9-EDE9

0 2,5 5 7,5 10

0

30

60

90

120

150

0 10 20 30 400

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]

2→1

1→2

EDA9

PERFORMANCES

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.

01 02

ED

1

2

1

2

1

2EDC9 EDA9 EDE9

12,7

3/4-16UNF-2A

27,

6 7

1,2

24

EMERGENZA A SVITARE(Unscrew emergency)

1

2

(0.50)

(1.0

9)(2

.80)

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 0,50 cm3/min - 10 gocce/min Max leakage 0,30 in3/min - 10 drops/min

Page 7: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Aggiornamento - Update 20N-2020

I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

VALVES & SOLUTIONS

125

VALVOLE A COMANDO ELETTRICO A CURSORE SAE8 3 VIE/2 POSIZIONI DIRETTE3 WAYS/2 POSITIONS SAE8 ELECTRIC SPOOL VALVES - DIRECT ACTINGEV10

61,

8 3

9,7

14,2

15,8

3/4-16UNF-2A

24

EMERGENZA SPINGI E GIRA

(1.5

6)

(0.56)

(Push and Twist emergency)

(2.4

3)

(0.62)

1

2

3

01

VALVOLE A COMANDO ELETTRICO A CURSORE SAE8 3 VIE/2 POSIZIONI DIRETTE

(3 WAYS/2 POSITIONS SAE8 ELECTRIC SPOOL VALVES - DIRECT ACTING)

EV

02 SCHEMA(CIRCUIT)

Vedi schema(See diagram)

C10

Vedi schema(See diagram)

E10

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIO (Nm)TIGHTENING TORQUE (lbt ft)

CAVITÀCAVITY

EV10 3/4-16UNF-2A 12 (3.2) 210 (3045) 0,15 (0.33) 30 (22) SAE 8/3

01 02

EV

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

0 1,25 2,5 3,75 5

0

30

60

90

120

150

0 5 10 15 200

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]

2→1

3→2

PERFORMANCES

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.

EVC10 EVE1013

2

13

2

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 60 cm3/min Max leakage 36 in3/min

Page 8: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

126 I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

Aggiornamento - Update 20N-2020

VALVES & SOLUTIONS

0 1,25 2,5 3,75 5

0

30

60

90

120

150

0 5 10 15 200

2

4

6

8

10[bar]

[USgpm]

[l/min]

[PSI]

2→1

3→2

39,

5 6

1,7

14,2

15,8

3/4-16UNF-2A

24

EMERGENZA A SVITARE(Unscrew emergency)

3

1

2

(0.62)

(0.56)

(1.5

6)(2

.43)

01

VALVOLE A COMANDO ELETTRICOA CURSORE SAE8 3 VIE/2 POSIZIONI DIRETTA

(3 WAYS/2 POSITIONS SAE8 ELECTRIC SPOOL VALVES - DIRECT ACTING)

EV

02SCHEMA(CIRCUIT)

Vedi schema(See diagram)

C11

Vedi schema(See diagram)

E11

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EV11 3/4-16UNF-2A 12 (3.2) 210 (3045) 0,15 (0.33) 30 (22) SAE 8/3

PERFORMANCES

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature, with a supply voltage 10% below the nominal value.

VALVOLE A COMANDO ELETTRICO A CURSORE SAE8 3 VIE/2 POSIZIONI DIRETTA3 WAYS/2 POSITIONS SAE8 ELECTRIC SPOOL VALVES - DIRECT ACTINGEV11

01 02

EV

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

EVC11 EVE11

2

1 3

2

1 3

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°F

Temperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 60 cm3/min Max leakage 36 in3/min

Page 9: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Aggiornamento - Update 20N-2020

I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

VALVES & SOLUTIONS

127

VALVOLE A COMANDO ELETTRICO SAE10 2 VIE/2 POSIZIONI PILOTATE2 WAYS/2 POSITIONS SAE10 ELECTRIC VALVES - PILOT OPERATEDEV30

01VALVOLE A COMANDO ELETTRICO SAE10 2 VIE/2 POSIZIONI PILOTATE

(2 WAYS/2 POSITIONS SAE10 ELECTRIC VALVES - PILOT OPERATED)EV

02SCHEMA(CIRCUIT)

Normalmente chiusa(Normally closed)

C30

Normalmente chiusa + emergenza(Normally closed + emergency)

E30

Normalmente aperta(Normally open)

A30

0 2,5 5 7,5 10 12,5 15 17,5

0

45

90

135

180

225

0 10 20 30 40 50 60 700

3

6

9

12

15[bar]

[USgpm]

[l/min]

[PSI]

2→1

1→2

PERFORMANCES

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature,with a supply voltage 10% below the nominal value.

TIPOTYPE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EV30 7/8-14UNF-2A 70 (18.5) 350 (5075) 0,19 (0.40) 40 (30) SAE 10/2

01 02

EV

7/8-14UNF-2A

15,8

32

68,

8 27

EMERGENZA A SVITARE

(2.7

1)

(0.62)

1

2

(Unscrew emergency)

(1.2

6)

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

1

2

1

2

1

2EVC30 EVA30 EVE30

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°FTemperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 0,25 cm3/min - 5 gocce/min Max leakage 0,015 in3/min - 5 drops/min

Page 10: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

128 I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

Aggiornamento - Update 20N-2020

VALVES & SOLUTIONS

VALVOLE A COMANDO ELETTRICO SAE10 DOPPIA TENUTA 2 VIE/2 POSIZIONI PILOTATE2 WAYS/2 POSITIONS SAE10 DOUBLE SEALING ELECTRIC VALVES - PILOT OPERATEDEV34

7/8-14UNF-2A

15,8

32

68,

8

27

EMERGENZA A SVITARE

(2.7

1)

(0.62)

1

2

(Unscrew emergency)

(1.2

6)

01

VALVOLE A COMANDO ELETTRICO SAE10DOPPIA TENUTA 2 VIE/2 POSIZIONI PILOTATE

(2 WAYS/2 POSITIONS SAE10 DOUBLESEALING ELECTRIC VALVES - PILOT OPERATED)

EV

02 SCHEMA(CIRCUIT)

Normalmente chiusa(Normally closed)

C34

Normalmente chiusa + emergenza(Normally closed + emergency) E34

Normalmente aperta(Normally open)

A34

0 2,5 5 7,5 10 12,5 15 17,5

0

45

90

135

180

225

0 10 20 30 40 50 60 700

3

6

9

12

15[bar]

[USgpm]

[l/min]

[PSI]

2→1

1→2

PERFORMANCES

Le prove sono state eseguite con solenoidi a temperatura di regime, sottoalimentati del 10% rispetto al valore nominale.

Tests carried out with solenoids at their working temperature,with a supply voltage 10% below the nominal value.

CODICECODE A PORTATA MAX (l/min)

MAX FLOW (USgpm)PRESSIONE MAX (bar)MAX PRESSURE (PSI)

PESO APPROX (kg)APPROX WEIGHT (lbt)

COPPIA DI SERRAGGIOTIGHTENING TORQUE

Nm-lbt ft

CAVITÀCAVITY

EV34 7/8-14UNF-2A 70 (18.5) 350 (5075) 0,19 (0.40) 40 (30) SAE 10/2

01 02

EV

BOBINA 22 W E CONNETTORE VEDI PG. 129-130

22 W COIL AND CONNECTOR SEE PG. 129-130

1

2

1

2

1

2EVC34 EVA34 EVE34

SCHEMA IDRAULICO / HYDRAULIC CIRCUIT

CODICE ORDINAZIONEORDERING CODE

DATI TECNICI / TECHNICAL DATA

CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Olio idraulico - Mineral oil ISO 6743/4 (DIN 51524)

Viscosità olio - Oil viscosity 15-250 mm2/s (15 to 250 cSt)

Classe di contaminazione max con filtro ISO 4406:1999 Classe 18/16/13Max contamination index with filter

Temperatura dell'olio - Oil temperature -20°C +80°C -4°F + 176°FTemperatura ambiente - Environment temperature -20°C +50°C -4°F + 122°F

È indispensabile l’utilizzo di un filtro per proteggere la valvola (filtrazione consigliata 15 μm)It is necessary a filter use to protect the valve (advised filtration 15 μm)

Trafilamento massimo 0,25 cm3/min - 5 gocce/min Max leakage 0,015 in3/min - 5 drops/min

Page 11: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

Aggiornamento - Update 20N-2020

I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

VALVES & SOLUTIONS

129

BOBINE

13

,2

42

45,

7

30 39

(0.5

2)

(1.6

5)

(1.8

0)

(1.54) (1.18)

13

,2

35,7

44,

3

48

38,5

(0.5

2)

(1.8

9)

(1.7

4)

(1.41)(1.52)

TIPOTYPE

TENSIONEVOLTAGE

CONNETTORE CONNECTOR

PESO APPROXAPPROX WEIGHT

EC012DC 12VDCStandard DIN 43650

88100002

0,14 kg0.30 lb

EC024DC 24VDC

EC22050 220-50/60 Hz Con raddrizzatore(With rectifier)

DIN 43650

88100003EC220RAC 220-50/60 Hz

COPPIA DI SERRAGGIO GHIERA BOBINA COIL NUT TIGHTENING TORQUE

2Nm

POTENZA ASSORBITA IN CAABSORBED POWER IN AC

20 VA

POTENZA ASSORBITA IN CCABSORBED POWER IN DC

18 W

POTENZA ASSORBITA ALLO SPUNTOABSORBED POWER IN PICKUP

28 VA

COPPIA DI SERRAGGIO GHIERA BOBINA COIL NUT TIGHTENING TORQUE

2Nm

POTENZA ASSORBITA IN CAABSORBED POWER IN AC

20 VA

POTENZA ASSORBITA IN CCABSORBED POWER IN DC

22 W

POTENZA ASSORBITA ALLO SPUNTOABSORBED POWER IN PICKUP

28 VA

TIPOTYPE

TENSIONEVOLTAGE

CONNETTORESTANDARD

STANDARD CONNECTOR

PESO APPROXAPPROX WEIGHT

EC36012DC 12VDCStandard DIN 43650

881000020,21 kg0.46 lb

EC36024DC 24VDC

EC36220RAC 220-50/60 Hz

Con raddrizzatore(With rectifier)

DIN 43650

88100003

18W 22W

COILS

DATI TECNICI / TECHNICAL DATA DATI TECNICI / TECHNICAL DATA

Page 12: ELECTRICAL VALVES - OleowebEVC6 EVA6 EVE6 SCHEMA IDRAULICO / HYDRAULIC CIRCUIT CODICE ORDINAZIONE ORDERING CODE DATI TECNICI / TECHNICAL DATA CARATTERISTICHE TECNICHE / TECHNICAL CHARACTERISTICS

130 I dati presenti nel catalogo possono essere soggetti a variazioni, pertanto OLEOWEB si riserva il diritto di apporre modifiche in qualunque momento e senza alcun preavviso.OLEOWEB reserves the right to modify the products at any time and without notice: the technical data of the catalogue can consequently change.

Aggiornamento - Update 20N-2020

VALVES & SOLUTIONS

27 31,5

42

(1.6

5)

(1.24)(1.06) 27

42

28

(1.6

5)

(1.10)(1.06)

CONNETTORE CON RADDRIZZATORE(CONNECTOR WITH RECTIFIER)

TIPO - TYPE: 88100003 EN 175301-803

CORRENTE NOMINALE CONTATTINOMINAL CURRENT 10 A

CORRENTE MAX CONTATTIMAX OPERATING CURRENT 16 A

RESISTENZA CONTATTICONTACT RESISTANCE ≤ 4m Ohm

SEZIONE MAX CONDUTTORIMAX CONDUCTORS CROSS-SECTION 1,5 mm2

PORTACONTATTI, DADOCONTACT HOLDER PA

TIPO DI SERRACAVOGLAND SIZE OPTIONS Pg09

DIAMENTRO CAVOCABLE DIAMETER 6-8 mm

GRADO DI PROTEZIONEPROTECTION CLASS IP 65 EN 60529

CLASSE DI ISOLAMENTOINSULATION CLASS VDE 0110-1/89

GUARNIZIONESEALING MATERIAL NBR

TEMPERATURA DI ESERCIZIOOPERATING TEMPERATURE -40C +90C

PESO APPROXAPPROX WEIGHT

0,025 kg0.055 lb

CONNETTORE STANDARD(STANDARD CONNECTOR)

TIPO - TYPE: 88100002 EN 175301-803

TENSIONE NOMINALENOMINAL V OLTAGE

AC - Max 250 VDC - Max 300 V

CORRENTE NOMINALE CONTATTINOMINAL CURRENT 10 A

CORRENTE MAX CONTATTIMAX OPERATING CURRENT 16 A

RESISTENZA CONTATTICONTACT RESISTANCE ≤ 4m Ohm

SEZIONE MAX CONDUTTORIMAX CONDUCTORS CROSS-SECTION 1,5 mm2

PROTEZIONEHOUSING PA (+G)

TIPO DI SERRACAVOGLAND SIZE OPTIONS Pg11

DIAMENTRO CAVOCABLE DIAMETER 6-8 mm

GRADO DI PROTEZIONEPROTECTION CLASS IP 65 EN 60529

CLASSE DI ISOLAMENTOINSULATION CLASS VDE 0110-1/89

GUARNIZIONESEALING MATERIAL NBR

TEMPERATURA DI ESERCIZIOOPERATING TEMPERATURE -40C +90C

PESO APPROXAPPROX WEIGHT

0,020 kg0.044 lb

CONNETTORI CONNECTORS