FCPS
V
M
C
VI
AV
B
C
DC
M
B
KP
SSCP
CR
SS
AS
TS
G
NCC
M
P
E
A
L
B1
B2
S
SRS
X
X
X
CB
EMERGENCY PUSH STATION
CODE BLUE STATION
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVE
GLASS BREAK
DS
DUPLEX RECEPTACLE
TEACHER STATION
ADMINISTRATION STATION
STUDENT STATION
CARD READER
CARBON MONOXIDE DETECTOR
H
DOCK LIGHT FIXTURE
3
CONTROL MODULE
TELEPHONE / DATA OUTLET
DUTY STATION
STAFF STATION
STAFF REGISTER STATION
DOME LIGHT
DUAL BED STATION
SINGLE BED STATION
BED / LIGHT INTERFACE
PENDENT INTERFACE
EMERGENCY PULL STATION
MASTER STATION
NURSE CALL CONTROLLER
NURSE CALL
ADDENDUM NOTE
PLAN NOTE
DEMOLITION NOTE
THREE PHASE MOTOR
BELL
AUDIO / VIDEO INPUT
VIDEO INPUT
WALL MOUNTED SPEAKER / CLOCK COMBO
WALL MOUNTED SPEAKER
DUAL FACE CLOCK
CCTV CONTROL PANEL
SECURITY SYSTEM CONTROL PANEL
KEY PAD
BEAM DETECTOR
MOTION DETECTOR
DOOR CONTACT
CAMERA
MONITOR MODULE
FIRE CONTROL POWER SUPPLY
VISUAL ONLY UNIT
ELECTRICAL SYMBOLS LEGEND
DH
V
S
C
M
I
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
SINGLE FACE CLOCK
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS
LIGHT FIXTURE
STRIP FIXTURE
IN-GRADE LIGHT FIXTURE
SPOTLIGHT (number of heads shown)
EXIT SIGN (face & direction as shown)
WALL MOUNT LIGHT FIXTURE
CEILING LIGHT FIXTURE
TRACK & FIXTURE
STREET TYPE POLE FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXTERIOR WALL MOUNT LIGHT FIXTURE
WALLPACK LIGHT FIXTURE
SPECIAL PURPOSE LIGHT FIXTURE
HIGH BAY LIGHT FIXTURE
EMERGENCY EGRESS LIGHT FIXTURE
(number of heads shown)
EMERGENCY LIGHT FIXTURE
FIXTURES
SWITCHES
SINGLE-POLE SWITCH
DIMMER SWITCH
TIME SWITCH
KEY SWITCH
MANUAL MOTOR SWITCH
THERMAL OVERLOAD SWITCH
SWITCH WITH PILOT LIGHT
FOUR-WAY SWITCH
THREE-WAY SWITCH
CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
MECHANICAL
ELECTRIC WATER HEATER
ELECTRIC UNIT HEATER
PIPE TRACE HEATER
RESISTANCE HEATER, KW SHOWN
SINGLE PHASE MOTOR
SOUND and SIGNAL
INTERCOM OUTLET
MICROPHONE OUTLET
TELEVISION OUTLET
CHIME
BUZZER
VOLUME CONTROL
SPEAKER
SERVICE and EQUIPMENT
THERMOSTAT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER (BY x/C U.O.N.)
MAGNETIC STARTER (BY x/C U.O.N.)
DISCONNECT SWITCH (fuse size shown)
TRANSFORMER
CONTROL
xxVA connection by x/C)
IRRIGATION CONTROLLER (120 volt
LIGHTING CONTACTOR
CONTROL TRANSFORMER
buttons indicated)
PUSHBUTTON STATION (number of
TIME CLOCK (24 hour U.O.N.)
PHOTOCELL (voltage as required)
HUMIDISTAT
FIRE ALARM
TAMPER SWITCH (furnished by FP/C)
FLOW SWITCH (furnished by FP/C)
FIREFIGHTER COMMUNICATION JACK
MAGNETIC DOOR HOLDER
REMOTE INDICATING LIGHT, CLG. MTD.
REMOTE INDICATING LIGHT, WALL MTD.
END OF LINE DEVICE
ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
PULL STATION
SPEAKER & LIGHT
SPEAKER
HORN
DUCT SMOKE DETECTOR
HEAT DETECTOR
SMOKE DETECTOR
HORN & LIGHT
DESIGNATIONS
(by E.C.)
(by others)
TT
FACP
ANN
EOL
G
WW
PC
CT
TS
T
H
TC
IC
F
FC
F
T
1,3
OR
PM
WM
BD
UFD
B
F
S
J
J
D
WH
PP
J
SENSOR SWITCH WSD-PDT SERIES
SWITCH STYLE OCCUPANCY SENSOR
OC
WATT STOPPER TS-400
DIGITAL TIME SWITCH
SENSOR SWITCH MP20 SERIES
POWER PACK
SENSOR SWITCH CMR-PDT SERIES
ULTRASONIC SENSOR - 360° - 500 SQ FT
SENSOR SWITCH CMR-PDT-10
ULTRASONIC SENSOR - 360° - 1000 SQ FT
SENSOR SWITCH CMR-PDT-10-2P
ULTRASONIC SENSOR - 360° - 2 CIRCUIT
SENSOR SWITCH CMR-PC-ADC SERIES
OCCUPANCY SENSOR / PHOTOCELL
SENSOR SWITCH WV-PDT-16 SERIES
WALL MOUNT DUAL TECHNOLOGY SENSOR
OS5
OS4
T
OS2
OS3
OS1
DUCT SMOKE DETECTOR
F/S
CEILING MOUNTED WIFI
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST (E)
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
GENERAL ELECTRICAL NOTES
FIXTURE
MOUNTING
HEIGHT
LAMPSDESCRIPTION AND COMMENTSTYPE MANUFACTURER CATALOG NO.
LIGHTING FIXTURE SCHEDULE
BALLAST INFO
sheet no.
puorg
www.mayottearchitects.com
f. 517-323-0570t. 517-323-0577
Lansing, MI 489176240 W Mt Hope
consultant
drawn by
checked by
date
architect job no.
contract order no.
index no.
file no.
2017-066
67025
084/17314.CDP
DESCRIPTION OF WORK
WORK SHALL INCLUDE BUT NOT NECESSARILY BE LIMITED TO THE FOLLOWING:
1. WIRING METHODS.
2. DEVICES.
3. LIGHTING.
4. TEMPORARY POWER AND LIGHTING.
STANDARDS
MATERIALS AND EQUIPMENT SHALL CONFORM TO THE REQUIREMENTS OF MBC, NEC, MIOSHA, NFPA, U.L., NEMA, A.D.A., AND
RESPECTIVE PUBLICATIONS AND OTHER REQUIREMENTS SPECIFIED BELOW. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH RECOMMENDATIONS OF THE MANUFACTURER.
CODES AND ORDINANCES
COMPLY WITH ALL CODES AND ORDINANCES. BIDDERS SHALL INFORM THEMSELVES OF CODE REQUIREMENTS.
PERMITS, INSPECTION FEES, AND CODES
THE CONTRACTOR SHALL OBTAIN AND PAY ALL PERMIT AND INSPECTION FEES. FINAL INSPECTION CERTIFICATES BY THE LOCAL
ELECTRICAL INSPECTOR AND FIRE MARSHAL SHALL BE OBTAINED BY THE CONTRACTOR AND TURNED OVER IN DUPLICATE TO THE
OWNER.
SUBMISSIONS
SUBMIT PRODUCT DATA, SHOP DRAWINGS, WIRING DIAGRAMS, AND DESCRIPTIVE LITERATURE ON ALL MATERIALS AND EQUIPMENT.
MAKE SUBMITTALS WITHIN THIRTY (30) DAYS AFTER THE SIGNING OF THE CONTRACT. SHIPMENT SHALL NOT BE RELEASED UNTIL
DRAWINGS AND LITERATURE HAVE BEEN FINALLY APPROVED.
AS-BUILTS - OPERATION & MAINTENANCE MANUALS
PROVIDE FOR EACH SYSTEM AND EQUIPMENT AS SPECIFIED FOR USE BY OPERATION AND MAINTENANCE PERSONNEL. THE
OPERATING INSTRUCTIONS SHALL INCLUDE:
WIRING DIAGRAMS, CONTROL DIAGRAMS, AND CONTROL SEQUENCE FOR EACH SYSTEM AND ITEM OF EQUIPMENT.
START-UP, PROPER ADJUSTMENT, OPERATING, LUBRICATION, AND SHUTDOWN PROCEDURES.
SAFETY PRECAUTIONS
THE PROCEDURE IN THE EVENT OF EQUIPMENT FAILURE
OTHER ITEMS OF INSTRUCTION AS RECOMMENDED BY THE MANUFACTURER OF EACH SYSTEM OR ITEM OF EQUIPMENT.
IDENTIFICATION OF SYSTEMS
OPERATING INSTRUCTIONS: PRINT OR ENGRAVE INSTRUCTIONS AND FRAME UNDER GLASS OR APPROVED LAMINATED PLASTIC. POST
INSTRUCTIONS IN VIEW OF EQUIPMENT. PROVIDE WEATHER RESISTANT MATERIALS FOR EXTERIOR APPLICATIONS.
EQUIPMENT: PROVIDE NAMEPLATE FOR ALL EQUIPMENT IT SHALL BE A SELF-ADHESIVE, ENGRAVED, LAMINATED ACRYLIC OR
MELAMINE LABEL. PROVIDE ADHESIVE BACK, WITH WHITE LETTERS ON A DARK GRAY BACKGROUND. MINIMUM LETTER HEIGHT SHALL
BE 3/8-INCH.
WARNING SIGNS: PROVIDE A SELF-ADHESIVE WARNING LABEL THAT IS FACTORY PRINTED, MULTI-COLOR, PRESSURE SENSITIVE,
ADHESIVE LABEL. COMPLY WITH N.E.C. 70 AND 29 CFR 1910.145. LABELS FOR MULTIPLE POWER SOURCES SHALL READ: “DANGER -
ELECTRICAL SHOCK HAZARD - EQUIPMENT HAS MULTIPLE POWER SOURCES”. LABELS FOR ALL OTHER EQUIPMENT REQUIRING WORK
SPACE CLEARANCES SHALL READ: “WARNING - OSHA REGULATION - AREA IN FRONT OF ELECTRICAL EQUIPMENT MUST BE KEPT CLEAR
FOR 36-INCHES”.
GUARANTEE
PROVIDE GUARANTEE FOR ALL LABOR AND MATERIALS FOR ONE (1) YEAR AFTER OWNER'S WRITTEN ACCEPTANCE OF THE PROJECT.
LAYOUT OF THE WORK
EXAMINE THE SITE AND ALL THE DRAWINGS BEFORE PROCEEDING WITH THE LAYOUT AND INSTALLATION OF THIS WORK. LOCATE
ESSENTIALLY AS SHOWN ON THE DRAWINGS, BUT IN EXACT LAYOUT DETERMINED ON THE JOB, TO SUIT ACTUAL CONDITIONS.
CONFER AND COOPERATE WITH OTHER TRADES ON THE JOB SO ALL PARTS WILL BE INSTALLED IN PROPER RELATIONSHIP. PRECISE
LOCATION OF PARTS TO COORDINATE WITH OTHER WORK IS THE RESPONSIBILITY OF THE CONTRACTOR.
CUTTING AND PATCHING
ALL NECESSARY CUTTING OF THE BUILDING CONSTRUCTION FOR THE NEW INSTALLATION OF THE WORK SHALL BE FURNISHED BY THE
CONTRACTOR. NO STRUCTURAL MEMBERS OF THE BUILDING SHALL BE CUT WITHOUT PRIOR APPROVAL OF THE ARCHITECT. ALL
NECESSARY PATCHING OF THESE SURFACES TO BE FURNISHED BY THIS CONTRACTOR.
WIRE AND CABLE
ALL WIRING SHALL STRANDED COPPER AND INSTALLED IN CONDUIT, TUBING, OR SURFACE METALLIC RACEWAY. CONDUCTORS SHALL
BE CONTINUOUS BETWEEN OUTLETS OF JUNCTION BOXES WITH SPLICES MADE ONLY WITHIN SUCH BOXES. SOLDERLESS
PRESSURE-TYPE CONNECTORS PROPERLY INSULATED SHALL BE USED FOR ALL JOINTS. NO WIRE SMALLER THAN #12 MAY BE USED
UNLESS SPECIFICALLY SPECIFIED UNDER DESCRIPTIONS OF SPECIAL SYSTEMS.
CONDUIT
ALL CONDUIT SHALL BE 3/4-INCH MINIMUM UNLESS NOTED OTHERWISE. WIRING METHODS:
EXTERIOR EXPOSED AND CONCEALED: RGC,
UNDERGROUND: PVC SCHEDULE 40,
INTERIOR EXPOSED/CONCEALED UNDER 2-INCHES: EMT,
INTERIOR EXPOSED/CONCEALED 2-INCHES AND LARGER: RGC,
CONNECTIONS TO VIBRATING EQUIPMENT: LFMC.
KEEP RACEWAYS AT LEAST 6-INCHES FROM PARALLEL RUNS OF FLUES, STEAM AND HOT WATER PIPING. INSTALL HORIZONTAL
CONDUIT RUNS ABOVE WATER AND STEAM PIPING. INSTALL RACEWAYS LEVEL AND SQUARE AND AT PROPER ELEVATIONS. PROTECT
STUB UPS FROM DAMAGE WHERE CONDUITS RISE THROUGH FLOOR SLABS AND ARRANGE SO CURVED PORTION OF BENDS ARE NOT
VISIBLE ABOVE THE FINISHED SLAB. INSTALL RACEWAYS IN MIDDLE THIRD OF SLAB WITH MINIMUM OF 1-INCH CONCRETE COVER.
SECURE RACEWAYS TO REINFORCING RODS TO PREVENT SAGGING OR SHIFTING DURING CONCRETE PLACEMENT. SPACE RACEWAYS
LATERALLY TO PREVENT VOIDS IN CONCRETE. RUN CONDUIT LARGER THAN 1-INCH TRADE SIZE PARALLEL TO OR AT RIGHT ANGLES
TO MAIN REINFORCEMENT. WHERE AT RIGHT ANGLES TO REINFORCEMENT, PLACE CONDUIT CLOSE TO SLAB SUPPORT.
OUTLET BOXES
A STANDARD GALVANIZED OUTLET BOX, COMPLETE WITH PLASTER RING, IF NECESSARY, SHALL BE INSTALLED FOR EACH AND EVERY
FIXTURE AND OUTLET SHOWN. EACH OUTLET SHALL BE RIGIDLY SUPPORTED FROM THE BUILDING CONSTRUCTION (INDEPENDENT OF
THE RACEWAY SYSTEM). CEILING OUTLET BOXES SHALL BE 4-INCH OCTAGON, 1-1/2-INCH DEEP, WITH FIXTURE HICKEY, AND
SUPPORTED TO WITHSTAND 80 LBS.
GROUNDING
ALL ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN A MANNER APPROVED BY THE LOCAL INSPECTOR.
LIGHTING FIXTURES
ALL LIGHTING FIXTURES AND COMPONENTS THEREOF SHALL BE U.L. AND E.T.L. APPROVED. FLUORESCENT FIXTURES SHALL BE
PROVIDED WITH H.P.F. LOW-NOISE LEVEL, TYPE 1 BALLASTS WITH FACTORY WIRED CARTRIDGE IN-LINE BALLAST FUSES UNLESS
NOTED OTHERWISE. IN FIREPROOF CONSTRUCTION INSTALLATIONS, NO WOOD OR OTHER FLAMMABLE MATERIAL MAY BE USED FOR
SUPPORTING, MOUNTING, OR INSTALLING FIXTURES. PROVIDE DISCONNECTING MEANS FOR ALL FLUORESCENT LUMINARIES THAT
UTILIZE DOUBLE-ENDED LAMPS AND CONTAIN BALLASTS THAT CAN BE SERVICED IN PLACE OR BALLASTED LUMINAIRES THAT ARE
SUPPLIED FROM MULTIWIRE BRANCH CIRCUITS AND CONTAIN BALLAST(S) THAT CAN BE SERVICED IN PLACE. THE DISCONNECTING
MEANS SHALL DISCONNECT SIMULTANEOUSLY FROM THE SOURCE OF SUPPLY ALL CONDUCTORS OF THE BALLAST, INCLUDING
GROUNDING CONDUCTOR.
WALL SWITCHES
SWITCHES SHALL BE SPECIFICATION GRADE TOGGLE TYPE, SINGLE-POLE, THREE-WAY TWO POSITION DEVICES RATED AT 20A.
CONVENIENCE OUTLETS
OUTLETS SHALL BE SPECIFICATIONS GRADE, 20A, 125VAC, 2-POLE, 3-WIRE DUPLEX CONFORMING TO NEMA WD 6, NEMA 5-20R UNLESS
NOTED OTHERWISE.
WALL PLATES
ALL DEVICE PLATES SHALL BE NON-CONDUCTIVE, THERMOPLASTIC, COLOR TO MATCH DEVICES, AND MEET FEDERAL SPECIFICATION
WP455-A.
SUPPORTS AND HANGERS
PROVIDE AND INSTALL NECESSARY STEEL BRACKETS, RODS, CLAMPS, ETC., FOR SUPPORT OF ALL WORK UNDER THIS CONTRACT.
END OF DIVISION 26
DIVISION 26
ELECTRICAL SPECIFICATIONS
sheet no.
puorg
www.mayottearchitects.com
f. 517-323-0570t. 517-323-0577
Lansing, MI 489176240 W Mt Hope
consultant
drawn by
checked by
date
architect job no.
contract order no.
index no.
file no.
2017-066
67025
084/17314.CDP
OS4 OS4 OS4
OS4 OS4 OS4
AC-9
EXISTING LIGHT FIXTURE TO REMAIN.
EXISTING DEVICE TO REMAIN.
EXISTING EQUIPMENT TO REMAIN.
DISCONNECT & REMOVE EXISTING LIGHT FIXTURE.
ASSOCIATED CONDUIT & WIRE TO REMAIN FOR NEW
FIXTURE.
DISCONNECT & REMOVE EXISTING LIGHT FIXTURE. EXTEND
ASSOCIATED CONDUIT & WIRE TO NEW LOCATION.
DISCONNECT & REMOVE EXISTING DEVICE. REMOVE
ASSOCIATED CONDUIT & WIRE.
OWNER SHALL REMOVE ALL I.T. EQUIPMENT AND DEVICES
PRIOR TO DEMOLITION WORK.
DISCONNECT & REMOVE EXISTING EQUIPMENT. REMOVE
ASSOCIATED CONDUIT & WIRE.
DISCONNECT & REMOVE EXISTING DEVICE BY OWNER.
REMOVE ASSOCIATED CONDUIT & WIRE.
DISCONNECT & RELOCATE EXISTING LIGHT FIXTURE. EXTEND
ASSOCIATED CONDUIT & WIRE TO NEW LOCATION.
DISCONNECT & REMOVE EXISTING TAMPER AND FLOW
SWITCH. REMOVE ASSOCIATED CONDUIT & WIRE.
CONTRACTOR SHALL COORDINATE REMOVAL OF DEVICES
WITH MECHANICAL.
DEMOLITION NOTES
sheet no.
puorg
www.mayottearchitects.com
f. 517-323-0570t. 517-323-0577
Lansing, MI 489176240 W Mt Hope
consultant
drawn by
checked by
date
architect job no.
contract order no.
index no.
file no.
2017-066
67025
084/17314.CDP
N
ELECTRICAL KEY NOTES
EXTEND EXISTING CONDUIT & WIRE TO NEW LOCATION.
REUSE EXISTING LIGHTING CIRCUIT.
OWNER PROVIDED DIMMER SWITCH.
RELOCATED LIGHT FIXTURE.
EX EX
XA
LA
LA LA
LA LA LA
LA
LA LA LA
LA
LA
LA
LALAEM
LALA
LALA
LA
LA
LA
LA
LA
LAEM
LA
LA
LA
LA
LA
CORRIDOREXIST
CONFERENCE208
LEVEL 17 OFFICE207
EXEXEXEX
sheet no.
puorg
www.mayottearchitects.com
f. 517-323-0570t. 517-323-0577
Lansing, MI 489176240 W Mt Hope
consultant
drawn by
checked by
date
architect job no.
contract order no.
index no.
file no.
2017-066
67025
084/17314.CDP
N
ELECTRICAL KEY NOTES
NEW FURNITURE WHIP. WIRE TO UNDER FLOOR JUNCTION
BOX AS SHOWN.
1. ALL FURNITURE FEEDS WITH SHARED NEUTRALS SHALL BE TIED TO
BREAKERS WITH COMMON TRIP.
GENERAL ELECTRICAL NOTES
EX
EX
EX
EX
EX
EXEX
EX
EX
EX
EXEX
EX EX
EX
EX
EXEX EX
EX EX EX
1RF3-31,33,351RF3-37,39,411RF3-25,27,29
1RF3-32
1RF3-34
1RF3-36
TV
84" AFF
TV
84" AFF
CORRIDOREXIST
CONFERENCE208
LEVEL 17 OFFICE207
sheet no.
puorg
www.mayottearchitects.com
f. 517-323-0570t. 517-323-0577
Lansing, MI 489176240 W Mt Hope
consultant
drawn by
checked by
date
architect job no.
contract order no.
index no.
file no.
2017-066
67025
084/17314.CDP
N