    Study Program: Electrical Engineering

    Group 2Name: 1. Mr. Arman Ramadhan (6312010006)

    2. Ms. Andi Meuthia A. (6312010005)

    3. Mr. Rizky Maulana (6312010015)

    4. Mr. Nanda Gita O (6312010012)

    STATE POLYTECHNIC OF JAKARTA - CEVEST

  • 8/10/2019 Electrical Engineering Report Presentation

    2/13

    1. All ECE laboratory reports shall follow the format outlined on the EE

    laboratory Cover Sheets (bookstore).

    2. No food or beverage is to be brought into the EE laboratories. Smoking is not permitted in the laboratory.

    3. Safe engineering practice shall be followed in all experimental work. Particular care shall be taken around

    line voltages, electrical machinery and special apparatus. All instructors and students shall know the location of the

    main disconnect for their laboratory area.

    4. Laboratory periods are assigned for specific classes. The heavy use of the laboratory facilities makes it

    virtually impossible to reschedule any laboratory. Instructors shall weigh laboratory participation as part of the

    course grade.

    5. Students may work in the laboratory only with proper supervision. Stu- dents wishing to use an operating

    laboratory shall request permission from the instructor assigned for those periods. Work accomplished outside the

    normal class period shall be signed by the instructor who is assigned for those periods.

    6. Defective test equipment shall be tagged by the instructor after verifica- tion that the item is not

    functioning properly. Instruction books for all equipment may be borrowed from the ECE stockroom library for

    use during the laboratory period. They must be returned to the ECE stockroom before the end of the period.

  • 8/10/2019 Electrical Engineering Report Presentation

    3/13

    1. Never hurry. Haste causes many accidents.

    2. Always see that power is connected to your equipment through a circuit breaker.

    3. Connect the power source last. Disconnect the power source first.

    4. Never make wiring changes on live circuits. Work deliberately and care- fully and check your

    work as you proceed. 5. Before connecting the power, check your wiring carefully for agreement with the wiring diagram

    for an accidental short-circuit and for loose connections.

    6. Check out the supply voltage to make sure that is what you expect. For example: AC or DC,

    15V, 20V, or 25V

    7. Do not cause short-circuits or high currents arcs. Burn from arcs may be very severe even at a

    distance of a few meters. Report all electrical burns to your instructor.

  • 8/10/2019 Electrical Engineering Report Presentation

    4/13

  • 8/10/2019 Electrical Engineering Report Presentation

    5/13

    quipment

    The tools used in measuring the voltage characteristics of incandescent lamps :

    1 . Screwdriver ( + ) and ( - )

    2 . Tang combination

    3 . Tang paring Isolation cable ( crocodile forceps )

    4 . AVO meters

    Materials needed to measure the voltage karakteristrik incandescent lamps :

    - NYM cables ( red , blue )

    - 1 piece induction regulator .

    - 1 piece AC voltmeter with a range of 300 V.

    - 1 piece AC ammeter with a range of 0.25 A .

    - 1 piece MCB board .

  • 8/10/2019 Electrical Engineering Report Presentation

    6/13

    1. Counting to determine the measuring instrument.

    2. Measure voltage load power.

    Dik : P in = 100 W incandescent lamp

    V = 220 voltsDit : i?

    Ans:

    I = P / (V)

    I = 100/220

    = 0,45 A

  • 8/10/2019 Electrical Engineering Report Presentation

    7/13

    Prepare tools

    Connect in accordance with the design drawings.

    Measure the results of the work

    Arrange results. .

    If there is something that does not make sense in the results, do the

    measurement again.

  • 8/10/2019 Electrical Engineering Report Presentation

    8/13

  • 8/10/2019 Electrical Engineering Report Presentation

    9/13

    Connect the stop contact 220 Volts on the

    mcb (at MCB input)

    Then, connect the MCB for output on input

    regulator

    Connect the output on terminal positive

    regulators on the voltmeter gauge.

    Connect output negative voltage regulators on

    terminal limits measure on the voltmeter

    gauge.

    On the terminal on the voltmeter gauge,

    connect the terminal to the on theamperemeters gauge.

    After that, the terminal limits measure on the

    amperemeter gauge, connect again to the

    incandescent lamp ( the positive voltage to

    the lamp ).

    And at the limit of measurement inmeasuring instrument voltmeter, connect the

    lamp on again can light up. ( the negative

    voltage to the lamp ).

  • 8/10/2019 Electrical Engineering Report Presentation

    10/13

    1 0 0 V 0 Light off

    2 10 10 V 0 005 Light dim

    3 20 20 V 0 007 Light dim

    4 30 30 V 0 009 Light dim

    5 40 40 V 0 0115 Light dim

    6 50 50 V 0 013 Bright lights

    7 60 60 V 0 115 Bright lights

    8 70 70 V 0 125 Bright lights

    9 80 80 V 0 14 Bright lights

    10 90 90 V 0 16 Bright lights

    11 100 100 V 0 175 Bright lights

    No Regulator Voltmeter Ampermeter Information

  • 8/10/2019 Electrical Engineering Report Presentation

    11/13

  • 8/10/2019 Electrical Engineering Report Presentation

    12/13

    Characteristics of the incandescent lamp when its voltage is above 50 V

    then the conclusion is already bright lights and when the voltage is below

    50 V then the dim light of the results of these measurements affect the

    voltage of the incandescent lamp.