Conductor Types Used For Overhead Lines (on photo: Transmission Line 69KV Upper and 25KV Lower Near Cypress Area, Cana da - by Wolf Read via Flick r) http://el ectri cal - e ng i ne e ri ng -porta l .com/con d uctor-type s-u sed - for-overhe a d - l i ne s Apri l 23, 2013 Conductor Types Used For Overhead Lines Aluminium and its alloys conductor steel reinforced The international standards covering most conduct or t ypes f or o verhead li nes are IEC 61089 (which supersedes IEC 207, 208, 209 and 210 ) and EN 50182 and 50183 (see Table 1). For 36 kV transmissi on and ab ove both aluminium con ductor steel reinforced (  ACS R ) and all alumini um alloy cond uctor (  AAA C ) may be co nsidered.  Alumini um conductor all oy reinforced (  ACA R ) and all aluminium all oy co nductors steel reinforced (AA CSR) are less common than AAAC and all such conductors may be more expensive t han ACSR. Relevant national and international standards St andard Title Comment IEC 61089 Round wire concentric lay overhead ele ct ri cal s t randed c onductors Supersedes IEC 207 (A AC), 208 (AAAC), 209 (ACSR) and 210 (AACSR) EN 50182 Conducto r f or overhead lines: round wire concent ri c l ay stranded c onduct or Supersedes I EC 61089 f or European use. BSEN 50182 identical EN Conduct o r f o r overhead lines: alumi nium

Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

  • Upload
    ecsanyi

  • View
    225

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

7/30/2019 Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

http://slidepdf.com/reader/full/electrical-engineering-portalcom-conductor-types-used-for-overhead-lines 1/6

Conductor Types Used For Overhead Lines (on photo: Transmission Line 69KV Upper and25KV Lower Near Cypress Area, Canada - by Wolf Read via Flickr)

http://electrical-engineering-portal.com/conductor- types-used- for-overhead- lines April 23, 2013

Conductor Types Used For Overhead Lines

Aluminium and its alloys conductor steel reinforced

The international standards covering most conductor t ypes for overhead lines are IEC 61089(which supersedes IEC 207, 208, 209 and 210 ) and EN 50182 and 50183 (see Table 1).

For 36 kV transmission and above both aluminium conductor steel reinforced ( ACSR ) and

all aluminium alloy conductor ( AAAC ) may be considered. Aluminium conductor alloy reinforced ( ACAR ) and all aluminium alloy conductors steel reinforced (AACSR) are lesscommon than AAAC and all such conductors may be more expensive than ACSR.

Relevant national and international standards

Standard Tit le Comment

IEC61089

Round wire concentric lay overheadelectrical stranded conductors

Supersedes IEC 207 (AAC), 208(AAAC), 209 (ACSR) and 210

(AACSR)

EN50182

Conductor for overhead lines: round wireconcentric lay stranded conductor 

Supersedes IEC 61089 for European use. BSEN 50182 identical

EN Conductor for overhead lines: aluminium–

Page 2: Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

7/30/2019 Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

http://slidepdf.com/reader/full/electrical-engineering-portalcom-conductor-types-used-for-overhead-lines 2/6

50183 magnesium–silicon alloy wires

BS 183 Specif ication for generalpurpose galvanized steel wire st rand

For earth wire

BS 7884 Specif ication for copper and copper–cadmium conductors for overheadsystems

Historically ACSR has been widely used because of its mechanical strength, the widespreadmanufacturing capacity and cost effectiveness.

For all but local distribution, copper-based overhead lines are more costly because of thecopper conductor material costs. Copper (BS 7884 applies) has a very high corrosionresistance and is able to withstand desert conditions under sand blasting.

 All aluminium conductors (AAC) are also employed at local distribution voltage levels.

From a materials point of view the choice between ACSR and AAAC is not so obvious and atlarger conducto r sizes t he AAAC opt ion becomes more attractive. AAAC can achievesignificant strength/weight ratios and for some constructions gives smaller sag and/or lower tower heights. With regard to long-term creep or relaxation, ACSR with its steel core isconsiderably less likely to be affected.

Jointing does not impose insurmount able dif f iculties for either ACSR or AAAC types of conductor as long as normal conductor cleaning and general preparation are observed. AAAC isslight ly easier to joint than ACSR.

Figure 1 illustrates t ypical strandings of ACSR. The conductor, with an outer layer of 

segmented strands, has a smooth surface and a slightly reduced diameter for t he sameelectrical area.

Page 3: Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

7/30/2019 Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

http://slidepdf.com/reader/full/electrical-engineering-portalcom-conductor-types-used-for-overhead-lines 3/6

Page 4: Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

7/30/2019 Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

http://slidepdf.com/reader/full/electrical-engineering-portalcom-conductor-types-used-for-overhead-lines 4/6

Historicallythere hasbeen nostandard

Page 5: Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

7/30/2019 Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

http://slidepdf.com/reader/full/electrical-engineering-portalcom-conductor-types-used-for-overhead-lines 5/6

Figure 1 - Conducto r arrangements f or dif f erent CSR combinations

nomenclature for overhead line conductors, although in some parts of the world code nameshave been used based on animal ( ACSR – UK ), bird ( ACSR – North America), insect ( AAAC –UK ) or f lower ( AAAC – North America) names to represent certain conductor types.

 Aluminium-based conductors have been referred to by their nominal aluminium area. Thus, ACSR with 54 Al strands surrounding seven steel strands, all strands of diameter d 3.18 mm,

was designated 54/7/3.18; alu area 428.9 mm2 , steel area 55.6 mm2 and described as having a

nominal aluminium area of 400 mm2 .

In France, the conductor tot al area of 485 mm2 is quot ed and in Germany the aluminium andsteel areas, 429/56, are quoted . In Canada and USA, the area is quoted in circular mils (1000

circular mils 0.507 mm2 ).

Within Europe standard EN50182 has coordinated these codes while permitt ing each country

to retain the actual dif ferent conductor types via the National Normative Aspects (NNAs).

Table below explains the EN 50182 designation system.

Conductor designation system to EN50182:2001

1. A designat ion system is used to identify stranded conductors made of aluminium with or without steel wires.

2. Homogeneous aluminium conductors are designated ALx , where x identifies the t ypeof aluminium. Homogeneous aluminium-clad steel conductors are designated yzSA where

y represents the type of steel (Grade A or B, applicable to class 20SA only ), and zrepresents the class of aluminium cladding (20, 21, 30 or 40 ).

3. Composite aluminium/zinc coated steel conductors are designated ALxISTyz , where ALx identifies the external aluminium wires (envelope), and STyz identifies the steel core.In the designation of zinc coated steel wires, y represents the type of steel (Grades 1 to6) and z represents the class of zinc coat ing (A to E).

4. Composite aluminium/aluminium-clad steel conductors are designated ALxIyzSA,where ALx identifies the external aluminium wires (envelope), and yzSA identifies the steelcore as in 2.

5. Conductors are identified as follows:

1. A code number giving the nominal area, rounded to an integer, of the aluminium or steel as appropriate;

2. A designat ion identifying the type of wires const itut ing the conductor. For composite conductors the f irst descript ion applies to the envelope and the secondto the core.

The development of ‘Gap type’ heat-resistant conductors of fers the possibility of higher conductor temperatures.

The design involves an extra high strength galvanized steel core, and heat-resistant aluminium alloy outer layers, separated by a gap f illed with heat-resistant grease. To maintainthe gap, the wires of the inner layer of the aluminium alloy are trapezoid shaped. Depending onthe allo s used, tem eratures of up to 210°C are ossible, with a current carr in ca acit of 

Page 6: Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

7/30/2019 Electrical-Engineering-portal.com-Conductor Types Used for Overhead Lines

http://slidepdf.com/reader/full/electrical-engineering-portalcom-conductor-types-used-for-overhead-lines 6/6

up to twice that o f hard-drawn aluminium.

This offers particular value where projects involve upgrading existing circuits.

Resource: Transmission and Distribution Electrical Engineering by Dr C. R. Bayliss CEng FIET and B. J. Hardy ACGI CEng FIET 