1
The electric detection system consists of a control panel and a linear heat detection line. The control panel main features are: Configuration of one or two detection zones. Programmable extinguishing delay 0-60 sec Both open and closed circuit in case of failure Three access levels Electronic control for electric power Five communication signals: manual actuation, blocked system, fault, alarm, and FWRE for SMS Two outlets for activation, both supervised. Low electric power consumption in stand-by state Communication unit compatible for SMS Alert mode and test mode Battery charger included Meets EN 54 parts 2 and 4, and EN 2094-1 Additional Features: Extinguishing activation signal. Illuminated acoustic signal Two batteries required: 12V and 4/5/7Ah Indoor horn Optical acoustic Addressable tones Easy installation Yellow Extinguishing switch Blue Abort switch SMS communication unit. Connection between TSA-2000XE and any SMS user is available. Voice message send out Thermal detector line: Available for 68/88/105/178 0 C level detection. Mallea- ble, easy to install, efficient, and UL approved. Control Panel / Linear Heat Detection Line Electrical Detecon & Control

Electrical Detection & Control · The electric detection system consists of a control panel and a linear heat detection line. The control panel main features are: • Configuration

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Electrical Detection & Control · The electric detection system consists of a control panel and a linear heat detection line. The control panel main features are: • Configuration

The electric detection system consists of a control panel and a linear heat detection line.

The control panel main features are:

• Configurationofoneortwodetectionzones.• Programmableextinguishingdelay0-60sec• Bothopenandclosedcircuitincaseoffailure• Three access levels• Electroniccontrolforelectricpower• Fivecommunicationsignals:manualactuation,

blockedsystem,fault,alarm,andFWREforSMS• Twooutletsforactivation,bothsupervised.• Lowelectricpowerconsumptioninstand-bystate• CommunicationunitcompatibleforSMS• Alert mode and test mode• Batterychargerincluded• MeetsEN54parts2and4,andEN2094-1

Additional Features:

• Extinguishingactivationsignal.Illuminatedacousticsignal

• Twobatteriesrequired:12Vand4/5/7Ah• Indoorhorn• Opticalacoustic• Addressabletones• Easy installation• YellowExtinguishingswitch• BlueAbortswitch• SMScommunicationunit.Connectionbetween

TSA-2000XEandanySMSuserisavailable.• Voicemessagesendout

Thermal detector line:

Availablefor68/88/105/1780Cleveldetection.Mallea-ble,easytoinstall,efficient,andULapproved.

Control Panel / Linear Heat Detection Line

ElectricalDetection & Control