Stellantriebe
Available in
Electrical actuatorfor industrial applications
ARIS Stellantriebe GmbH
ARIS Stellantriebe GmbH – Your experienced partner. For many years, the ARIS brand stands for high quality and customized solutions in all areas of industrial plant and machinery:
Environmental engineering Pharmaceutical industry Food industry Heater/Burner Furnaces Public services Supplier
ARIS Actuators and valveswork in various applications:
Dosing pumps Industrial burners Air conditioning and ventilation Boilers Painting lines Blinds Industrial furnaces Autoclaves
The Allrounder – Compact and robustClassic actuator technology
With the Nano+ series ARIS offers a new generation of robust actuators in the smallest possible space. Powder-coated housing and hoods ensure safe and reliable operation even in harsh industrial environments. The practical and optimized design of the Nano+ manages a comfortable setting and a fast electrical connection.
The classic actuator technology with synchronous or DC motor ensures easy replacement of actuators in existing circuits and plants. From the outset the design has been considered all market standard options, so that easy commissioning is ensured even when the actuator is fully equipped. All options have their distinct position and are designed so that all electrically conductive parts are securely covered. Thus provides the Nano+ maximum security in a compact space.
Several mounting holes and a changeable shaft system ensure simple mounting on all common valves. Of course, all shaft types and mounting hole circles of earlier series have been taken into account, so that it is possible to replace older drives without changing the existing system.
The shafts of the base drive and the additional gear run on ball bearings. This achieves the Nano+ precision and durability that are higher than other drive concepts. An always up and down guided construction of the limit switches and a hollow shaft potentiometer directly built on the shaft provide the basis for a precise cut-off and position detection, which form the basis for a high efficiency of your investment.
www.stellantriebe.de
„For our specific requirements for torque and small spacesthe Nano+ is perfectly suitable.“
Minimal base area –Compact design up to 120 Nm.
„In our systems Ex and standard drives are used together.The uniform size facilitates planning.“
„With our gas control systems, we attach great importance to a precise flow control. The Nano+ meets these requirements perfectly. „
„
ATEX zone 2/22 with similar dimensions as the standard type –Ultra compact and cost efficient, since there is no pressurized encapsulation required.
Increase efficiency of plants by high precision potentiometer position feedback, thanks to the
hollow shaft potentiometer directly mounted on the drive shaft.
„
„
ARIS Stellantriebe GmbH
Specifications AC DC
Motor Synchronous motor, short-circuit proof Direct current brush motor
Protection class IP 65 (optional IP 66)
Ambient temperature –15 °C...+60 °C/optional –40 °C...+80 °C (with PMR: 0 °C...+60 °C)
Housing Die cast aluminum (EN AC-44200) powder-coated
Gear Metal
Cover Aluminum EN AW-6060 T6 / powder-coated
Shaft 1.4021
Position indicator optional
Power supply 230 V AC (optional 115 V AC/24 V AC) 24 V DC ±20%
Additional switches 2 or 4 Stück (optional)
Potentiometer optional
Travel 10°...330° (optional Multi-Turn)
Duty cycle 100%
Connection 3 cable glands M16x1,5
Travel cutoff Switching cams/Micro switches
Maintenance Lifetime lubrication (maintenance-free)
Control 3-point-step 2-wire-technology
Other values upon request
TypeAC
TypeDC
Torque [Nm] Actuating time [s/90°] Torque [Nm] Actuating time [s/90°]
Nano+ S 05-008 5 0.8 (0.7) Nano+ S-DC 05-03 5 3
Nano+ S 05-03 5 3 (2.5) Nano+ S-DC 05-06 5 6
Nano+ S 05-06 5 6 (5) Nano+ S-DC 05-10 5 10
Nano+ S 05-15 5 15 (13) Nano+ S-DC 05-15 5 15
Nano+ S 05-30 5 30 (25) Nano+ S-DC 05-30 5 30
Nano+ S 05-60 5 60 (50) Nano+ S-DC 05-45 5 45
Nano+ S 10-008 10 0.8 (0.7) Nano+ S-DC 10-03 10 3
Nano+ S 10-03 10 3 (2.5) Nano+ S-DC 10-06 10 6
Nano+ S 10-06 10 6 (5) Nano+ S-DC 10-10 10 10
Nano+ S 10-15 10 15 (13) Nano+ S-DC 10-15 10 15
Nano+ S 10-30 10 30 (25) Nano+ S-DC 10-30 10 30
Nano+ S 10-60 10 60 (50) Nano+ S-DC 10-45 10 45
Nano+ S 15-03 15 3 (2.5) Nano+ S-DC 15-06 15 6
Nano+ S 15-06 15 6 (5) Nano+ S-DC 15-10 15 10
Nano+ S 15-15 15 15 (13) Nano+ S-DC 15-15 15 15
Nano+ S 15-30 15 30 (25) Nano+ S-DC 15-30 15 30
Nano+ S 15-60 15 60 (50) Nano+ S-DC 15-45 15 45
Nano+ S 20-02 20 1.5 (1.3) Nano+ S-DC 20-06 20 6
Nano+ S 20-06 20 6 (5) Nano+ S-DC 20-10 20 10
Nano+ S 20-15 20 15 (13) Nano+ S-DC 20-15 20 15
Nano+ S 20-30 20 30 (25) Nano+ S-DC 20-30 20 30
Nano+ S 20-60 20 60 (50) Nano+ S-DC 20-45 20 45
Type listS
Values in ( ) = 60 Hz
www.stellantriebe.de
DimensionsNano+ S S
40
6
5
12
63H
204kt SW11
40
124
3
16
t=2,5
10
3025
8
65
2525
F05 50F03 36
50
H= 74mm/ 105mm/ 145mm
86
153
M6x10
M5x8
M6x10
42
11
ø ø
ø
ø
ø
ø
ø
Cable glands optional(Standard=Blind plugs)
Position indicatoroptional
D-Shaft(Option)
Round shaft withcross hole(Standard)
depending on type
Round shaft withfeather key(Option)
ISO shaftinner 4-square(Option)
ARIS Stellantriebe GmbH
Specifications AC DC
Motor Synchronous motor, short-circuit proof Direct current brush motor
Protection class IP 65 (optional IP 66)
Ambient temperature –15 °C...+60 °C/optional –40 °C...+80 °C (with PMR: 0 °C...+60 °C)
Housing Die cast aluminum (EN AC-44200) powder-coated
Gear Metal
Cover Aluminum EN AW-6060 T6 / powder-coated
Shaft 1.4021
Position indicator optional
Power supply 230 V AC (optional 115 V AC/24 V AC) 24 V DC ±20%
Additional switches 2 or 4 Stück (optional)
Potentiometer optional
Travel 30 bis 40 Nm: 10°...150° / 50 bis 60 Nm: 10°...100° (optional Multi-Turn)
Duty cycle 100%
Connection 3 cable glands M16x1,5
Travel cutoff Switching cams/Micro switches
Maintenance Lifetime lubrication (maintenance-free)
Control 3-point-step 2-wire-technology
Other values upon request
TypeAC
TypeDC
Torque [Nm] Actuating time [s/90°] Torque [Nm] Actuating time [s/90°]
Nano+ M 25-03 30 3 (2.5) Nano+ M-DC 30-07 30 7
Nano+ M 30-08 30 8 (7) Nano+ M-DC 30-10 30 10
Nano+ M 30-12 30 12 (10) Nano+ M-DC 30-15 30 15
Nano+ M 30-30 30 30 (25) Nano+ M-DC 30-30 30 30
Nano+ M 30-60 30 60 (50) Nano+ M-DC 30-60 30 60
Nano+ M 30-120 30 120 (100) Nano+ M-DC 30-100 30 100
Nano+ M 40-03 40 3 (2.5) Nano+ M-DC 40-10 40 10
Nano+ M 40-12 40 12 (10) Nano+ M-DC 40-15 40 15
Nano+ M 40-30 40 30 (25) Nano+ M-DC 40-30 40 30
Nano+ M 40-60 40 60 (50) Nano+ M-DC 40-60 40 60
Nano+ M 40-120 40 120 (100) Nano+ M-DC 40-100 40 100
Nano+ M 50-12 50 12 (10) Nano+ M-DC 50-20 50 20
Nano+ M 50-20 50 20 (17) Nano+ M-DC 50-30 50 30
Nano+ M 50-50 50 50 (42) Nano+ M-DC 50-60 50 60
Nano+ M 50-90 50 90 (75) Nano+ M-DC 50-100 50 100
Nano+ M 50-180 50 180 (150) Nano+ M-DC 60-20 60 20
Nano+ M 60-05 60 5 (4.2) Nano+ M-DC 60-30 60 30
Nano+ M 60-20 60 20 (17) Nano+ M-DC 60-60 60 60
Nano+ M 60-50 60 50 (42) Nano+ M-DC 60-100 60 100
Nano+ M 60-90 60 90 (75)
Nano+ M 60-180 60 180 (150)
Type listM
Values in ( ) = 60 Hz
www.stellantriebe.de
DimensionsNano+ M M
14
D
40
D
4 kt SW14
B
6 40
P
3
L
T
H= 74mm/ 105mm/ 145mm
4063
H86
153
2525
82
50
65
M6x11
M6x11
D B L P T
30 40 Nm 12 5 16 4 2,5
50 60 Nm 14 6 22 5 3
F05 50ø
Cable glands optional(Standard=Blind plugs)
Position indicatoroptional
Round shaft withcross hole(Standard)
depending on type
Round shaft withfeather key(Option)
ISO shaftinner 4-square(Option)
Type
to
to
ARIS Stellantriebe GmbH
Specifications AC DC
Motor Synchronous motor, short-circuit proof Direct current brush motor
Protection class IP 65 (optional IP 66)
Ambient temperature –15 °C...+60 °C/optional –40 °C...+80 °C (with PMR: 0 °C...+60 °C)
Housing Die cast aluminum (EN AC-44200) powder-coated
Gear Metal
Cover Aluminum EN AW-6060 T6 / powder-coated
Shaft 1.4021
Position indicator optional
Power supply 230 V AC (optional 115 V AC/24 V AC) 24 V DC ±20%
Additional switches 2 or 4 Stück (optional)
Potentiometer optional
Travel 10°...330° (optional Multi-Turn)
Duty cycle 100%
Connection 3 cable glands M16x1,5
Travel cutoff Switching cams/Micro switches
Maintenance Lifetime lubrication (maintenance-free)
Control 3-point-step 2-wire-technology
Other values upon request.
TypeAC
TypeDC
Torque [Nm] Actuating time [s/90°] Torque [Nm] Actuating time [s/90°]
Nano+ L 70-06 70 6 (5) Nano+ L-DC 80-25 80 25
Nano+ L 80-10 80 10 (8) Nano+ L-DC 80-30 80 30
Nano+ L 80-15 80 15 (13) Nano+ L-DC 80-45 80 45
Nano+ L 80-25 80 25 (21) Nano+ L-DC 80-60 80 60
Nano+ L 80-45 80 45 (38) Nano+ L-DC 100-30 100 30
Nano+ L 80-60 80 60 (50) Nano+ L-DC 100-45 100 45
Nano+ L 80-80 80 80 (67) Nano+ L-DC 100-60 100 60
Nano+ L 80-210 80 210 (175) Nano+ L-DC 100-70 100 70
Nano+ L 100-10 100 10 (8) Nano+ L-DC 120-30 120 30
Nano+ L 100-15 100 15 (13) Nano+ L-DC 120-40 120 40
Nano+ L 100-25 100 25 (21) Nano+ L-DC 120-45 120 45
Nano+ L 100-40 100 40 (33) Nano+ L-DC 120-60 120 60
Nano+ L 100-80 100 80 (67) Nano+ L-DC 120-70 120 70
Nano+ L 100-210 100 210 (175)
Nano+ L 120-10 120 10 (8)
Nano+ L 120-15 120 15 (13)
Nano+ L 120-25 120 25 (21)
Nano+ L 120-40 120 40 (33)
Nano+ L 120-80 120 80 (67)
Nano+ L 120-110 120 110 (92)
Nano+ L 120-210 120 210 (175)
Type listL
Values in ( ) = 60 Hz
www.stellantriebe.de
DimensionsNano+ L L
H= 74mm/ 105mm/ 145mm
45
6 3
22
20
t=3,5
H63
153
8
21,6
4kt SW17
M8x16
F07 70
1020
45
2525
63
42
86
ø
ø
ø
ø
Cable glands optional(Standard=Blind plugs)
Position indicatoroptional
Round shaft withcross hole(Standard)
depending on type
Round shaft withfeather key(Option)
ISO shaftinner 4-square(Option)
ARIS Stellantriebe GmbH
PMR-Nano (AC)
■ Power supply: 230 V ±10%, 50/60 Hz Special voltages/-frequencies available
■ Set value input: 0 (4) to 20 mA (DC), optional 0 (2) to 10 V Burden 250 Ω, overload protection 25 mA Reverse voltage protection up to –25 mA Resolution 10 bit
■ Actual value output: Fixed limits: 0 or 4-20 mA (Option 0 or 2-10 V) Current drain, burden max. 500 Ω Resolution 10 bit
Service switch (Standard at DC)
■ Manual-/Automatic operation (switch) ■ CW/CCW run (button) ■ Integrated inside actuator
Two or four additional auxiliary switches
■ Setup via tool-free adjustable switching cams ■ Different cam shapes offer different functionalities of auxiliary switches ■ High switching safety by spacer between circuit board and cam shaft
Cams
■ 330° / 180° ■ With threaded pin for safe fixing
Mechanical position indicator
■ Freely adjustable
Multi-Turn
■ Optional special resolution for potentiometer and shutoff system
■ For applications with more than 1 revolutions
Options
Hand wheel
■ Automatic disengaging ■ Not rotating with shaft
www.stellantriebe.de
Potentiometer
Standard ■ 1 kΩ/10 kΩ ■ Resolution: Nano S+L 90°/180°/320°, Nano M 30...40 Nm 10°...150°,
Nano M 50...60 Nm 10°...100° (optional Multi-Turn)
Potentiometer refeed acc. to DIN EN 12067-2 ■ Regulation of fuel, air and exhaust streams in combination with electronic
compound regulating system ■ Certified actuator and potentiometer ■ Continuous form closure from the actuator shaft to the potentiometer shaft ■ Vibration tested acc. to EN 60068-2-6 ■ Electrical testing of actuator acc. to DIN EN 60730
Current output (add-on board)
■ Position feedback 4–20 mA
Options
Parallel relays/Single wire operation (AC)
■ AC relay ■ Completely wired ■ Operation voltage=Motor voltage ■ Parallel connection of several actuators
Heating
■ For heating of the actuator´s interior against water condensation
Fail-safe
■ Energy storage ■ Run to a pre-defined position on power cutoff ■ Charging time <3 minutes ■ Integrated inside actuator ■ Run with standard or high speed ■ 24 V DC
Cable entry adapter
■ For cable glands 3xM20 (instead of 3xM16) ■ Cable entry from the front ■ Anodized aluminum
ARIS Stellantriebe GmbH
Linearis N+
Actuating force max. 5000 N (higher forces available)
Actuating time 1.3 mm...13 mm/s (load independant at AC)
Travel 150/300 mm stroke (more stroke length available)
Voltage 230 V, 115 V, 24 V AC/24 V DC
Ambient temperature –15 °C...+60 °C (optional –40 °C...+80 °C)
Protection class IP 65 (optional up to IP 67)
Duty cycle 100%
LABS-free according to Daimler testing standard certified by Fraunhofer Institute.
■ Stainless steel high-helix lead screw Ø18 ■ Lead 40 mm with optimized efficiency
■ less turns per stroke length ■ long-life motor ■ slow and smooth motor movement ■ low noise and vibration
■ Holding torque by self-hold of the actuator ■ separately exchangeable actuator ■ High-strength, anodized milled aluminum parts, corrosion resistant and lightweight ■ Long holes for fastening, i.e. easy installation ■ Maintenance-free by dry-run, no lubrication necessary,
no dirt deposits on grease (longer life span) ■ Embedded (dry) lubricants inside the lead screw nut ■ Easily exchangeable with older ARIS damper actuators ■ High quality „dryspin® technology“, lead screw and nut made by igus©
More possible applications
More details on separate data sheet.
www.stellantriebe.de
Nano+ Ex (Zone 1) Ex II 2G Ex d IIC T6 Gb
■ Usable in Ex-Zones 1 and 2 ■ Appliance categories 2G and 3G ■ Flameproof „d“ ■ Usable at gases with increased flame transmission capacity „C“ ■ Highest temperature class T6 ■ For gases with ignition temperature > 85 °C
Flange connection ISO F05 and ARIS 65x50
Power supply 230 V, 115 V, 24 V AC/24 V DC
Ambient temperature –20 °C...+60 °C
Cable entry 1x M20x1.5 or 1x M20x1.5 + 1x M16x1.5
Housing Aluminum (painted), steel (base)
Ex protection Ex II 2G Ex d IIC T6 Gb
Protection class IP65
More possible applications
More details on separate data sheet.
II 3G Ex ec IIC T4 Gc X (Zone 2)
II 3D Ex tc IIIC T80°C Dc X (Zone 22) Ambient temperature: –15 °C ≤ Ta ≤ 45 °C
■ Compact layout (identical with standard actuator) ■ Small surcharge to standard actuator, lower price than with pressuri-
zed encapsulation ■ Usable in zone 2 or 22 ■ Dimensions and specifications same as standard actuator ■ High product safety by single check at factory
Nano+ Ex (Zone 2/22)
ARIS Stellantriebe GmbH
Complete units
Besides our high-tech actuators, ARIS delivers robust insdustrial valves too. On your demand, an ARIS technician designs a complete unit for you, consisting of valve, connecting parts and actuator. The pre-mounted complete unit is adjusted to the required parameters and tested for proper functionality. Packed and labeled ready for transport ARIS ships your product to your desired shipping address...worldwide!
Valve
Connectingparts
Actuator
+
+
www.stellantriebe.de
AC DC
1 Position indicator (optional) 9 Shaft sealing
2 Hollow shaft potentiometer 10 Drive shaft (also at Nano S)
3 Motor capacitor 11 Cable entry (optional)
4 End position switches 12 Die cast aluminum housing
5 Synchronous motor/DC motor 13 Gear addition
6 Aluminum switching cams 14 Gear addition housing 40/60 Nm (S+M)
7 Sandwich-Getriebe 15 Gear addition housing 120 Nm (L)
8 Ball bearing
2
4
6
8
10
12
1
3
5
7
9
11
14
LM13
5
10
15
SLM
www.stellantriebe.de
ARIS bridges gaps
You are faced with a problem in your system and are looking for an alternative or new solution?
40 years of experience and expertise in-house. Through newly created capacities our design department is located back at ARIS headquarters in Troisdorf/Germany in 2014. We develop and build high-quality electric actuators that are equipped with contemporary technology. Drives made by ARIS are created in close cooperation of engineers, technicians and the sales team with our clients. So we are able to develop marketable products from scratch and execute to the production stage under one roof. In addition to standard products, we can implement individual solutions for customer projects as well as special drives as OEM goods.
Come to ARIS – Your specialist for modern actuator technology „Made in Germany“.
Telefon +49 2241 25186-0Telefax +49 2241 25186-99
ARIS
Rotter Viehtrift 9D-53842 Troisdorf
ARIS Stellantriebe GmbH