Electrochemical Detector
Everyone can be an Expert
Autosampler
Complete HPLC-ECD
ECD-700
Eicom ECD-700 Electrochemical Detector for HPLC
Eicom ECD-700
Features
Eicom's electrochemical detector, the ECD-700, offers superior stability and sensitivity that reviles that of mass spectrometry detectors, but without the cost and special expertise. Electrochemical detectors easily detect a wide range of easily oxidized or reduced compounds, and you can rely of Eicom's extensive experience to help youfind the best set-up for your research goals. Depending of the requirements of a particular method, the ECD-700 can be configured with up to two detector cells. Both amperometric and coulometric types are available.
In amperometry the analyte contacts the surface of a solid working electrode. Amperometry achieves better signal-to-noise ratios resulting in better sensitivity. Coulometry depends on porous working electrode to promote the complete electrolysis of the analyte as it passes. At Eicom, we find the best approach is to employ coulometric cells to prepare the analyte for detection with an amperometric cell.
• High Sensitivity, 30 fg sensitivity for Dopamine at S/N ratio=3.• Easy system setup and “ready-to-use” applications.• Instant access to the working electrode of the amperometric detector cell.• Expandable design for more demanding users or protocols.
ConfigurationsStandardOne amperometric detector cell with single graphite working electrode.
A: Amperometric detector, dA: Dual amperometric working electrodes that share a common reference electrode and can be installed in parallel or series with the flow. C: Coulometric flow cell.
Optional Configurations
Standard
Option 1
Option 2
1st Detector CellA
dAA /dA
Option 3 A /dA/CAC
2nd Detector Cell
Coulometric Cell
Amperometric Cell
Amperometry Dual Amperometry Coulometry
or
Working Electrode Designs
Amperometry vs. Coulometry
Simplicity + ExpandabilityThe keyword during the development of the ECD-700 was “expandability”. Over the past 25 years of Eicom ECD products, our goal has been to help users “kick start” new projects with our “ready-to-use” applications and reliable instruments. And now for more demanding applications, we have introduced the ECD-700, which has two detector cell capacity and allows for many combinations of detector types and working electrodes.
Variety of Working Electrodes Materials
• Graphite Electrode WE-3G, very stable and best S/N ratio. Little maintenance is required. Included in the standard configuration.
• Pure Graphite WE-PG, stable even at higher applied voltage
• Glassy Carbon WE-GC, conventional working electrode
• Platinum WE-PT, good for hydrogen peroxide. Commonly used with inline enzyme reactor columns.
• Gold WE-AU, well suited for thiol group detection
• Silver WE-AG
Dual working electrode for use with Eicom's amperometric detector cell.
• Graphite WED-3G
• Glassy Carbon WED-GC
Coulometric detector cell working electrode material.
• Porous Carbon (refer to Option 3 on previous page)
Heart of Sensitivity, Amperometric Detector Cell
Diagram of Detector Cell
Eicom's advanced working electrode design requires much less maintenance than many ECD users may have become accustomed to. When the need does arise, the electrode can easily be accessed to replace it or wipe off any chemical build-up. Even after the cell is opened, the initial baseline signal is quickly restored without worry.
�e pressure inside the cell is maintained by a spring-loaded ball assembly that ensures a constant pressure. �e ball compresses the working electrode assembly at one point to evenly distribute the pressure across the working electrode.
EICOM
WE-XX
GS-XX
Working Electrode
Gasket
Eicom ECD-700
Many “Ready-to-use” applicationsEicom provides complete, step-by-step protocols for a variety of applications. These protocols include instructions for sample collection and preparation, mobile phase recipes, storage and preparation of standards, and exact instrument settings. If you want to modify a method or create your own method, we can advise you on where to start and give you feedback about the data along the way.
Pulse DamperElectrochemical detection is extremely sensitive to changes in pressure. Consequently, each stroke of an HPLC pump can cause oscillations in the baseline signal, which necessitates the use of a pulse damper to obtain the lowest detection limit. If you will not be using an Eicom pump, we recommend using a pulse damper, such as Eicom PL-500. A Pulse damper is not required for Eicom pumps.
Specifications of ECD-700 Standard Configuration
Typical EC detectable compounds
US Office7313 Carroll Road Suite F,San Diego, CA 92121Phone +1-888-680-7775 www.eicom-usa.com
Eicom Europe1A Dartmouth TerraceRanelagh Dublin 6, IrelandPhone +353-1-902-2700 www.eicomeurope.com
Headquarters113 Kitaenmendencho Shimotoba FushimikuKyoto-Shi Kyoto-Fu JapanPhone +81-75-622-2112www.eicom.co.jp
Columns
Detection Method
Working Electrode
Applied Potential Range
Auto Zero Function
Reference Electrode
Counter Electrode
Cell Volume
Inlet Tubing OD
Input
Output
Auto Zero Input
Log File
Amperometric, DC with 3 electrode potentiostat
Standard single graphite. Optional dual working electrode with a shared reference electrode.
-2,000 mV ~ +2,000 mV in increments of 1mV
-1,000 nA ~ +1,000 nA, resets in less than 0.7 sec. Each detector cell zeros separately.When dual electrode is installed, the signal from both applied voltages zero together.
Ag / AgCl
Stainless Steel 316
Active area = 1 µL. Outlet has 100 µL reservoir
1/16 inch
Contact closure signal, DC 0 V ~ 5 V, ON ≥ 1 mV OFF ≤ 10 µA
Delay of 0 sec, 3 sec and 6 sec after 1sec signal input
Accept DC 0 V ~ 5 V, ON ≥ 1 mV OFF ≤ 10 µA
User can save a log of reference and working electrode replacements for each channelthrough keypad
Phenols
Catechols
Indoles
Anilines
Quinones
Tocopherols
Estrogens
Hydroxycoumarins
Purines
Opiates
Phenothiazines
Thiols
Specification and design of products may change without notice.
Eicom ECD-700
Complete HPLC-ECD
Eicom 700 Series Complete HPLC-Electrochemical Detector System
Sensitivity comes from more than just the detector.
If you need the very best performance of Eicom ECD-700, we recommend using the three 700 Series components as one system. The 700 Series includes an HPLC Pump (EP-700), Temperature Controller (ATC-700) and Electrochemical Detector (ECD-700). When used together, we promise the best results.
To achieve optimal performance from electrochemical detectors, there are important considerations. The Eicom 700 Series Total System addresses all of these requirements to ensure the best sensitivity.
• A chemically inert or, at a minimum, passivated interior because metal ions increase the background signal • A means to stabilize the baseline because oscillations in the pressure caused by the HPLC pump produce concomitant oscillations in the signal baseline • Effective temperature control because electrochemical detection is very sensitive to temperature
Eicom EP-700 HPLC PumpNo more pulse dampers required! Revolutionary pump design can effectively quench flow pulses.
Built-in, computer control continually adjusts the piston velocity during each stroke to minimize fluctuations in the pressure. Pulse free pumping works in both gradient and isocratic modes. Because
Standard Configuration
EP-700M --- one micro flow pump (10 to 500 µL /min )
Options
EP-700H --- one high flow type pump
EP-700MM --- two micro flow pumps with gradient controller
EP-700HH --- two high flow pumps with gradient controller
EP-700MH --- one micro flow and one high flow pump
Eicom Complete 700 Series
the EP-700 does not require a damper, the volume between a column and the HPLC pump is minimal. This means rapid acquisition of steady-state pressure after starting the pump and more immediate solvent effects that are important to accurate gradients. An innovative 300 µL volume degasser is built in to guarantee continuous pumping and preventing noise at the detector.
Pulse-free ModeOFF
Pulse-free ModeON
Signal Baselines
Eicom ATC-700 Temperature Controller
Eicom AS-700 INSIGHT Autosampler
The Eicom ATC-700 uses a Peltier element that both heats and cools by convection to maintain precise temperature control. The system responds to just a 0.05°C change and controls the temperature of the both the columns and ECD cells.
We know your time is limited. Eicom's reliable autosampler injects samples while you are away. Autosamplers are must have item for knowledgeable HPLC users. For more details, please see the INSIGHT Autosampler brochure.
INSIGHT
SpecificationsSetting Range
Recommended Range
Dimension
Weight
Power Supply
15 to 55°C
Recommended Range; 20 to 45°C at 25°C ambient
400 (w) x 400 (d) x 145 (h) cm
about 10 kg
AC 100-240 V, 50/60 Hz, 210 VA
Type
Construction
Flow Rate Ranges
Liquid Contacting Surfaces
Pressure Limit
Gradient Mode
External Signal
Degassing Chamber Volume
Lines
Internal Volume
Maximum Flow Rate
Dimension
Weight
Power Supply
Temperature Regulation
Setting Range
Recommended Range
Column Capacity
Dimension
Weight
Power Supply
Pump Unit (EP-700)
Casing (EP-700)
Temperature Controller (ATC-700)
Degasser Unit (EP-700)
Specifications of EP-700 and ATC-700
Dual reciprocating piston pump
Chemically inert materials at all liquid contacting surfaces
Micro flow type:100 to 500 µL/min with 1 µL/min increments, 4 µL/stroke
High flow type:0.5 to 3.00 mL/min with 0.01 mL/min increments, 32 µL/stroke
PEEK, Sapphire, Ruby, PTFE, PCTFE
20 MPa
High pressure linear gradient, 10 steps.Available when 2 same pump installed.
Input: Gradeint Start/Stop, Gradient Initialization Output: Pump Pressure
300 µL x 2 channels
2 Channels
300 µL/channel
3 mL/min
400 (w) x 400 (d) x 190 (h) mm
approx. 13 kg with one pump, approx. 16 kg with two pumps
AC 100-240 V, 50/60 Hz, 200 W
Peltier device for heating and cooling by convection
15 to 55°C, 1°C increament
20 to 45°C at 25°C ambient
25 cm x 2 HPLC columns
400 (w) x 400 (d) x 145 (h) mm
approx. 10 kg
AC 100-240 V, 50/60 Hz, 210 VA
US Office7313 Carroll Road Suite F,San Diego, CA 92121Phone +1-888-680-7775 www.eicom-usa.com
Eicom Europe1A Dartmouth TerraceRanelagh Dublin 6, IrelandPhone +353-1-902-2700 www.eicomeurope.com
Headquarters113 Kitaenmendencho Shimotoba FushimikuKyoto-Shi Kyoto-Fu JapanPhone +81-75-622-2112www.eicom.co.jp
Eicom Complete 700 Series
Specification and design of products may change without notice.