Dr. Adel Al-Faraskoury Manager, Extra High Voltage Research Center, Egyptian Electricity Holding Company, Egypt Present Early Bird Discount Register and pay 25 days prior to the event date and get 15% discount. December 27 - 31, 2015 Dubai, UAE Partial Discharge (PD), Very Low Frequency (VLF) And Dissipation Factor (Tan δ )

EE-55 Power Cables Testing & Fault Location

Embed Size (px)

Citation preview

Page 1: EE-55 Power Cables Testing & Fault Location

Dr. Adel Al-Faraskoury

Manager, Extra High Voltage Research Center,

Egyptian Electricity Holding Company, Egypt

Present

Early Bird Discount Register and pay 25 days prior to the

event date and get 15% discount.

December 27 - 31, 2015

Dubai, UAE

Partial Discharge (PD), Very Low Frequency (VLF)

And Dissipation Factor (Tan δ )

Page 2: EE-55 Power Cables Testing & Fault Location

Power Cable fault locating and testing takes on a whole new dimension with the modular Cable Fault locating Concept

from Megger. We have geared our development to the industry requirements for a more tempered fault locating

method and have developed more sophisticated methods that reduce the stress on insulation systems.

In absence of CBM, the power or control cable fails without any notice. To find the fault is a very tedious job and

requires a lot of tools and combination of tools and expertise to locate the fault in the cable. Precise fault location can

save a lot of money and can reduce the down time for the customers and the power could be restored within the

shortest possible time

The Electricity Companies have to supply electricity to the consumers at the lowest possible cost commensurate with

safety. Power cables represent a major capital asset for electricity suppliers. While in service power cables must be

maintained and monitored in order to anticipate faults and possibility avert any failure.

Faults in underground cables can occur at any time, and the causes are many and varied. When faults do occur they

generally cause loss of supply to customers and loss of revenue for suppliers. So it is imperative that the fault location

process is efficient and accurate to minimize excavation time, which results in results in reducing the inconvenience to

all concerned. For fault locating to be efficient and accurate technical staff needs to have expert knowledge

accompanied with experience in order to attained service reliability.

After the end of the course, participants will be able to:

Understand the Essential Characteristics and Requirements of

Underground Cables.

Consolidate and updated understating of the Terminology used

in Measuring and Analysis.

Provide Methods and devise Solutions to improve Equipments

through the prediction and the avoidance of Power Cable Failure.

Use Casual Factor Chart to identify data to be collected produce

a Root Cause Map and Identify Root Causes.

Appreciate the Technical Options for Selection, Laying and

Maintenance of Power Cables.

Apply practices for Fault Detection and Location for Power

Cables and Identify Problems and Failure Modes of Cables

Perform Routine & Preventative Maintenance and Testing of

Power System and Analysis Issues from their workplace

implement underlying Concepts.

Engineers and Highly Technicians from Electrical

Power Utilities Companies, Manufactures and

Distributors of Power Cables, Engineering

Professional in Petrochemical Companies, and

Commercial Buildings.

Participants need no Specific Requirements other

than Basic Understanding of Electricity and

Magnetism and knowledge of nature and

Operation of Power Supply and Underground

Distribution System.

Course Overview:

Course Objectives: Who Should Attend?

Power Cables Testing & Fault Location

www.apex-dubai.com

The Presentation, supplied documents,

and workshop exercises of the course

are in English however, based

on the trainees’ desires, oral presentation or

discussion can be Bilingual

(English and Arabic).

Course Language:

Page 3: EE-55 Power Cables Testing & Fault Location

Module (01) Introduction to Testing of Cables

1.1 Life Cycle

1.2 Test Cycle

1.3 Routine Tests

1.4 Special Tests

1.5 Type Tests

1.6 Site Tests after Installation

Module (02) Cable Failures and their Analysis

2.1 Mechanical Failures

2.2 Corrosion of Sheath

2.3 Moisture in the Insulation

2.4 Heating of Cables / Heating Resources

2.5 Fire and Lightning Surges

2.6 Electrical Puncture

2.7 Insulation Defects

Module (03) Dielectric Losses

3.1 Dissipation Factor (tan )

3.2 Cables Measurements

3.3 Three Conductor Cable Insulation Diagram

3.4 Loss Measurement of Dissipation Factor

3.5 Analysis of Cable Measurements Results

3.6 Tan Instrument (Schering Bridge)

3.7 Tan Instrument (Latest Technology)

Module (04) Partial Discharge Techniques

4.1 What is Partial Discharge?

4.2 PD Detection for Cable Diagnostics

4.3 Why Test for Partial Discharge?

4.4 Physical Background of PD

4.5 Types of Partial Discharge

4.6 Characteristic of Discharge Patterns

4.7 Breakdown Cable Voltage

4.8 Partial Discharge Test Facility

4.9 Test Circuit inside Shielded Room

4.10 How to Calibrate the Partial Discharge System?

4.11 How to measure Partial Discharge?

4.12 Charge in Fault versus measured apparent charge

and Measurement Results

4.13 P D Measurement methods Available ( Test Van)

Module (05) Very Low Frequency VLF

5.1 Standard for on site Testing including VLF

5.2 Principle of VLF Generator

5.3 Dissipation Factor (tan )

5.4 Evaluation of (tan ) measurements based on XLPE

5.5 Water Treeing in Polymeric Insulation

5.6 Comparison of Electrical Treeing and Water treeing

5.7 Comparison Channel Growth

5.8 Simplified Dielectric Equivalent Circuit for New Cables

5.9 Examples of Water Trees

5.10 Application of VLF / PD Diagnosis

Module (06) Cable Fault Location and Tracing

6.1 Cable Fault Location Procedures

6.2 Cable Fault Types

6.3 PD Tracks in Slip Joins for Cables

6.4 Methods of Cable Fault Location

6.5 Time Domain Reflectometry (TDR)

6.6 Impulse Reflection Method IRM)

6.7 Secondary impulse Method (SIM)

6.8 Multiple Impulse Method (MIM)

6.9 Fault Distance from Cable End

6.10 Bridge Method (Wheatstone)

6.11 Cable Tracing

6.12 Cable Locator

6.13 Acoustic Fault Location

6.14 Propagation Time Measurement

6.15 Pin Pointing Set

6.16 Audio Frequency Twist Method

6.17 Cable Sheath Fault location

6.18 Cable Test Van

Module (07) Benefits of Cable Testing

7.1 Reduction of in service cable failures

7.2 Prioritization of cables in a cable replacement

Program Schedules

7.3 Answers with the ‘repair or replace” question

7.4 Development of Documented History Condition.

7.5 Cost Reduction due to reduced Cable Failure

Course Summary & Conclusion

www.apex-dubai.com

Power Cables Testing & Fault Location

Course Contents:

Page 4: EE-55 Power Cables Testing & Fault Location

Dr. Adel had B.SC in Electrical Power Engineering since 1982, from Helwan University , and he

had Diploma in High Voltage Engineering from Cairo University 1997. Also Dr. Adel had M.SC in

Power Quality Improvement in Primary Distribution Networks from Ain Shams University. He got

his Ph D. In High Voltage Insulations ageing due to Electrical Treeing and Partial Discharge

from Cairo university .

He is Manager of Partial Discharge Measuring Laboratory Extra High Voltage research Centre,

Egyptian Electricity Holding Company, Ministry of Electricity & Energy , Egypt. He occupied

many position in Ministry of Electricity & Energy , Egypt. Such as Low & Medium Voltage Electrical Insulation

Engineer, Electrical Maintenance Engineer. He performed a lot of inspection and Maintenance activities inside and

outside of Egypt related to Power Cables and on site of Cable Test System.

Dr. Adel had published (3) Papers , Power Quality Concerns in Industrial Plants, Important Power Quality aspects for

Industrial Customers, and Diagnostic Methods and on site preventive Maintenance of Power Transformers. He is

working with APEX as Technical Consultant and conducted many Training Programs in Electrical Engineering Field

with them in Middle East. As a conclusion of Dr. Adel that he is a highly dedicated and experienced Electrical Power

Professional with extensive Teaching and Research Skills over 26 years experience in Electrical Power Engineering,

and Consultation with major Power Companies.

A confirmation will be sent upon your registration.

Note that full payment must be made prior to the

event. Only those delegates who have paid in full will

be admitted to the event. All payments should be to

APEX Account:

Bank Name : HSBC Bank Middle East limited,

Branch : Jebel Ali Branch, Dubai, UAE

IBAN No : AE020200000035626472101

Swift Code : BBMEAEAD

Closing of Registration will be two (2) weeks prior

to the course date.

APEX can assist and provide corporate rates for the

hotel accommodation.

Course fees will cover Course Materials, Certificate

of Participation, Coffee Breaks and Lunch.

In-House course is also available upon request and

can be customized as per client’s needs.

Email : [email protected]

Fax : +971 4 454 2910

Website : www.apex-dubai.com

If you are unable to attend the course you may send

a substitute delegate.

Cancellation should be made 15 days prior to the

course conduction. Failure to cancel within 10 days will

be to pay the course fee in full amount.

The amount of 3500 USD will be charged for the course

fee and Full Payment is required prior to

commencement of the course.

Course Fees:

Payment Methods:

Cancellation:

Registration Methods:

General Information:

www.apex-dubai.com

Power Cables Testing & Fault Location

Course Instructor:

Tel : +971 4 445 8567

Fax : +971 4 454 2910

Email : [email protected]

Website : www.apex-dubai.com

Contact us: